{"id":184270,"date":"2026-11-15T11:45:19","date_gmt":"2026-11-15T09:45:26","guid":{"rendered":"https:\/\/prohoster.info\/blog\/news\/predstavlen-xraid-s-realizacziej-raid-dlya-xfs"},"modified":"2026-11-15T11:45:30","modified_gmt":"2026-11-15T09:45:30","slug":"xraid-introduced-with-raid-implementation-for-xfs","status":"publish","type":"post","link":"https:\/\/prohoster.info\/bs\/blog\/news\/xraid-introduced-with-raid-implementation-for-xfs","title":{"rendered":"Predstavljen XRAID sa implementacijom RAID za XFS","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Kristof Helwig (Christoph Hellwig), odr\u017eavatelj podklju\u010dnih DMA, KVM, Slab Allocator i arhitekture PowerPC u Linux jezgru, predstavio je prvo javno izdanje XRAID-a, implementacije deklasterizovanog RAID-a s kontrolom pariteta, integrisane u XFS datote\u010dni sistem. Projekat je stvoren s ciljem dodavanja mogu\u0107nosti kori\u0161\u0107enja RAID-a na zoniranim ure\u0111ajima za skladi\u0161tenje, kao \u0161to su SMR (Shingled Magnetic Recording) diskovi, i pru\u017eanja visoko performantne implementacije RAID-a za odr\u017eavanje integriteta podataka. Pored zoniranih ure\u0111aja, XRAID tako\u0111e podr\u017eava rad na obi\u010dnim tvrdim diskovima i SSD-ovima, pokazuju\u0107i kod potonjih zna\u010dajan porast performansi u pore\u0111enju s mdraid-om (do 20 puta prilikom pisanja).<\/p>\n<p> Za raspodelu informacija po ure\u0111ajima u XRAID-u koristi se deklasterizovana kontrola pariteta, koja podse\u0107a na dRAID u OpenZFS, pri \u010demu se za vru\u0107e zamenljive (hot spare) ure\u0111aje ne izdvajaju posebni diskovi, ve\u0107 se podaci, informacije o kontroli pariteta i slobodni rezervni prostor ravnomerno raspore\u0111uju po svim ure\u0111ajima. Proces \u010ditanja, pisanja i oporavka u slu\u010daju kvarova obuhvata sve dostupne ure\u0111aje, \u010dime se pove\u0107ava propusnost, smanjuje optere\u0107enje na pojedina\u010dnim diskovima, omogu\u0107ava izbegavanje zna\u010dajnog opadanja performansi tokom kvarova i znatno ubrzava proces rekonstrukcije niza nakon dodavanja ili zamene ure\u0111aja.<\/p>\n<p> Deklasterizovani RAID-ovi tako\u0111e pojednostavljuju kreiranje otpornim nizova sa veoma velikim brojem diskova. Tokom procesa oporavka nakon kvarova, XRAID dinami\u010dki odre\u0111uje redosled rekonstrukcije ure\u0111aja, prvo obra\u0111uju\u0107i zone s ve\u0107im gubitkom suvi\u0161ne informacije i rekonstrui\u0161u\u0107i zone s podacima pre zona s informacijama o kontroli pariteta.<\/p>\n<p>XRAID se prvobitno razvija s fokusom na mogu\u0107nost kori\u0161\u0107enja sa zoniranim skladi\u0161tima, gde se prostor za skladi\u0161tenje deli na zone koje \u010dine grupe blokova ili sektora. U ovim ure\u0111ajima dozvoljeno je samo sekvencijalno dodavanje podataka uz a\u017euriranje cele grupe blokova. Na primer, zoniranje zapisa se primenjuje na SMR (Shingled Magnetic Recording) diskovima, gde je \u0161irina staze manja od \u0161irine magnetske glave, a zapis se vr\u0161i sa delimi\u010dnim preklapanjem susedne staze, \u0161to zna\u010di da bilo kakvo ponovo zapisivanje zahteva ponovo zapisivanje cele grupe staza. <\/p>\n<p>Za podr\u0161ku zoniranim ure\u0111ajima u XRAID-u kori\u0161\u0107en je distribuirani alocator za zonirane ure\u0111aje (zoned allocator) implementiran u XFS i jezgru Linuxa, koji koristi RT podvolumen (RealTime subvolume) za organizaciju odvojenog skladi\u0161tenja podataka i metapodataka (u zonama sa sekvencijalnim zapisom se \u010duva samo sadr\u017eaj fajlova, dok se metapodaci fajlskog sistema sme\u0161taju u obi\u010dne zone ili na dodatne SSD diskove). <\/p>\n<p>U XRAID-u mehanizmi kontrole pariteta RAID se primenjuju samo na sadr\u017eaj fajlova, dok se redundancija za metapodatke implementira kori\u0161\u0107enjem ve\u0107 postoje\u0107ih drajvera u jezgru Linuxa, na primer, kroz umno\u017eavanje pomo\u0107u MD RAID-a, \u0161to je efikasnije za male objekte koji se a\u017euriraju na mestu. Implementacija RAID-a se ugra\u0111uje u XFS do obradnika zoniranog ulaza\/izlaza, predstavljaju\u0107i fizi\u010dke zone donjih skladi\u0161ta u obliku logi\u010dkih zona, sli\u010dno vi\u0161eslojnim blok ure\u0111ajima.<\/p>\n<p>Rad na XRAID-u traje ve\u0107 godinu i po, i iako implementacija jo\u0161 nije spremna za integraciju u glavni deo jezgra, ve\u0107 je pogodna za testiranje \u0161iroke publike. U predlo\u017eenoj implementaciji podr\u017eava se od 0 do 2 nivoa parnosti (u razvoju je kod za podr\u0161ku 3 i vi\u0161e nivoa). Za upravljanje XRAID-om, u alatima xfsprogs dodan je novi alat 'xraid' i implementirana je podr\u0161ka za XRAID u mkfs. Pored toga, u alat za inspekciju zoniranih skladi\u0161ta Zonar dodane su mogu\u0107nosti za vizualizaciju mapiranja logi\u010dkih zona na fizi\u010dke zone.<\/p>\n<p>Objavljeni su rezultati testiranja performansi XRAID-a u pore\u0111enju sa mdraid i btrfs, sprovedeni za XRAID skup u konfiguraciji od dva SSD diska WD DC-SN650 za metapodatke (mirroring zasnovan na mdraid), \u0161est obi\u010dnih SATA diskova WD DC-HC590 od 26 TB i 6-21 zoniranih diskova WD DC-HC690 od 30 TB (SMR).<\/p>\n<p><center><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/11\/1de7acac4a616cf25ff6b9e30b0035b5.png\" style=\"display:block;margin: 0 auto;\" \/><\/center><br \/>\n<center><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/11\/e2a008bd63933ed983e1ada0c6ef4719.png\" style=\"display:block;margin: 0 auto;\" \/><\/center><br \/>\n<center><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/11\/3dd7a1a9c6e6485013991499feabc165.png\" style=\"display:block;margin: 0 auto;\" \/><\/center><br \/>\n<center><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/11\/cdde54f30b448b99fb7e10c6bc3c06ff.png\" style=\"display:block;margin: 0 auto;\" \/><\/center><br \/>\n<center><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/11\/924ecf1e448d5c4f6490e880e0dcac96.png\" style=\"display:block;margin: 0 auto;\" \/><\/center><\/p>\n<p>Tako\u0111e su sprovedena testiranja XRAID-a na obi\u010dnim nezoniranim SSD-ima u konfiguraciji sa jednim 4 TiB Samsung PM9D3a za metapodatke i pet 4 TiB Samsung PM9D3a za RAID (4 + 1).<\/p>\n<p><center><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/11\/92b2fdcdaa49172de5b78de311898b88.png\" style=\"display:block;margin: 0 auto;\" \/><\/center><br \/>\n<center><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/11\/aa7c43a8b02f451cec46edcd47551cba.png\" style=\"display:block;margin: 0 auto;\" \/><\/center><br \/>\n<center><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/11\/db080e509d4157667576a50b93712c76.png\" style=\"display:block;margin: 0 auto;\" \/><\/center><\/p>\n<p><center><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/11\/a01529f0b830ed5e47c518da8b1cc58e.png\" style=\"display:block;margin: 0 auto;\" \/><\/center><br \/>\n<br \/>Izvor: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/www.opennet.ru\/opennews\/art.shtml?num=66692\">opennet.ru<\/a> <\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u041a\u0440\u0438\u0441\u0442\u043e\u0444 \u0425\u0435\u043b\u0432\u0438\u0433 (Christoph Hellwig), \u043c\u044d\u0439\u043d\u0442\u0435\u0439\u043d\u0435\u0440 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c DMA, KVM, Slab Allocator \u0438 \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u044b PowerPC \u0432 \u044f\u0434\u0440\u0435 Linux, \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u0438\u043b \u043f\u0435\u0440\u0432\u044b\u0439 \u043f\u0443\u0431\u043b\u0438\u0447\u043d\u044b\u0439 \u0432\u044b\u043f\u0443\u0441\u043a XRAID, \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u0434\u0435\u043a\u043b\u0430\u0441\u0442\u0435\u0440\u0438\u0437\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e RAID \u0441 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c \u0447\u0451\u0442\u043d\u043e\u0441\u0442\u0438, \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u0432 \u0444\u0430\u0439\u043b\u043e\u0432\u0443\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443 XFS. \u041f\u0440\u043e\u0435\u043a\u0442 \u0441\u043e\u0437\u0434\u0430\u043d \u0441 \u0446\u0435\u043b\u044c\u044e \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f RAID \u043d\u0430 \u0437\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445 \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f, \u0442\u0430\u043a\u0438\u0445 \u043a\u0430\u043a \u0434\u0438\u0441\u043a\u0438 SMR (Shingled Magnetic Recording), \u0438 \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0432\u044b\u0441\u043e\u043a\u043e\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":10,"featured_media":184272,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[702],"tags":[],"class_list":["post-184270","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u041a\u0440\u0438\u0441\u0442\u043e\u0444 \u0425\u0435\u043b\u0432\u0438\u0433 (Christoph Hellwig), \u043c\u044d\u0439\u043d\u0442\u0435\u0439\u043d\u0435\u0440 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c DMA, KVM, Slab Allocator \u0438 \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u044b PowerPC \u0432 \u044f\u0434\u0440\u0435 Linux, \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u0438\u043b \u043f\u0435\u0440\u0432\u044b\u0439 \u043f\u0443\u0431\u043b\u0438\u0447\u043d\u044b\u0439 \u0432\u044b\u043f\u0443\u0441\u043a XRAID, \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u0434\u0435\u043a\u043b\u0430\u0441\u0442\u0435\u0440\u0438\u0437\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e RAID \u0441 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Alexander Kovalev\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/bs\/blog\/news\/xraid-introduced-with-raid-implementation-for-xfs\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"bs_BA\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u041f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d XRAID \u0441 \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0435\u0439 RAID \u0434\u043b\u044f XFS | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u041a\u0440\u0438\u0441\u0442\u043e\u0444 \u0425\u0435\u043b\u0432\u0438\u0433 (Christoph Hellwig), \u043c\u044d\u0439\u043d\u0442\u0435\u0439\u043d\u0435\u0440 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c DMA, KVM, Slab Allocator \u0438 \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u044b PowerPC \u0432 \u044f\u0434\u0440\u0435 Linux, \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u0438\u043b \u043f\u0435\u0440\u0432\u044b\u0439 \u043f\u0443\u0431\u043b\u0438\u0447\u043d\u044b\u0439 \u0432\u044b\u043f\u0443\u0441\u043a XRAID, \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u0434\u0435\u043a\u043b\u0430\u0441\u0442\u0435\u0440\u0438\u0437\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e RAID \u0441 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/bs\/blog\/news\/xraid-introduced-with-raid-implementation-for-xfs\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-15T09:45:26+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-15T09:45:30+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Predstavljen je XRAID sa implementacijom RAID-a za XFS | ProHoster","description":"Kristof Helvij (Christoph Hellwig), odr\u017eava\u010d podsistema DMA, KVM, Slab Allocator i arhitekture PowerPC u Linux jezgru, predstavio je prvo javno izdanje XRAID-a, implementaciju deklasterizovanog RAID-a sa kontrolom.","canonical_url":"https:\/\/prohoster.info\/bs\/blog\/news\/xraid-introduced-with-raid-implementation-for-xfs","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"bs_BA","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u041f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d XRAID \u0441 \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0435\u0439 RAID \u0434\u043b\u044f XFS | ProHoster","og:description":"\u041a\u0440\u0438\u0441\u0442\u043e\u0444 \u0425\u0435\u043b\u0432\u0438\u0433 (Christoph Hellwig), \u043c\u044d\u0439\u043d\u0442\u0435\u0439\u043d\u0435\u0440 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c DMA, KVM, Slab Allocator \u0438 \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u044b PowerPC \u0432 \u044f\u0434\u0440\u0435 Linux, \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u0438\u043b \u043f\u0435\u0440\u0432\u044b\u0439 \u043f\u0443\u0431\u043b\u0438\u0447\u043d\u044b\u0439 \u0432\u044b\u043f\u0443\u0441\u043a XRAID, \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u0434\u0435\u043a\u043b\u0430\u0441\u0442\u0435\u0440\u0438\u0437\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e RAID \u0441 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c.","og:url":"https:\/\/prohoster.info\/bs\/blog\/news\/xraid-introduced-with-raid-implementation-for-xfs","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2026-11-15T09:45:26+00:00","article:modified_time":"2026-11-15T09:45:30+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":[],"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/posts\/184270","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/comments?post=184270"}],"version-history":[{"count":1,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/posts\/184270\/revisions"}],"predecessor-version":[{"id":184271,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/posts\/184270\/revisions\/184271"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/media\/184272"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/media?parent=184270"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/categories?post=184270"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/tags?post=184270"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}