{"id":38294,"date":"2019-10-31T22:22:48","date_gmt":"2019-10-31T19:22:48","guid":{"rendered":"https:\/\/prohoster.info\/blog\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\/"},"modified":"2019-10-31T22:22:48","modified_gmt":"2019-10-31T19:22:48","slug":"anboksing-stoechnogo-servera-cisco-ucs-c240-m5","status":"publish","type":"post","link":"https:\/\/prohoster.info\/bs\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","title":{"rendered":"Unboxing rack server Cisco UCS C240 M5","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Danas imamo na stolu novi rack server Cisco UCS C240 pete generacije. <\/p>\n<p>\u0160ta \u010dini ovaj Cisco server zanimljivim za unboxing, s obzirom na to da je pred nama ve\u0107 njegova peta generacija? <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing rack server Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/419d39ba895739a71b337f03445a9c32.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nPrvo, Cisco serveri sada podr\u017eavaju najnoviju generaciju procesora Intel Scalable druge generacije. Drugo, sada mo\u017eete instalirati Optane Memory module za kori\u0161\u0107enje vi\u0161e NVMe diskova. <br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nPostavljaju se razumna pitanja: zar serveri drugih proizvo\u0111a\u010da to ne mogu? \u0160ta je tu posebno, jer je to samo x86 server? O svemu redom. <\/p>\n<p>Osim zadataka autonomnog servera, Cisco C240 M5 mo\u017ee biti deo arhitekture Cisco UCS. Ovde govorimo o povezivanju sa FI i potpunom kontrolom servera putem UCS Manager-a, uklju\u010duju\u0107i Auto Deploy. <\/p>\n<p>Dakle, pred nama je \"hardverski\" server Cisco, peta generacija, vi\u0161e od 10 godina na tr\u017ei\u0161tu. <br \/>\nSada \u0107emo se vratiti osnovama, setiti se od kojih komponenti se sastoji server, i \u0161ta \u010dini Cisco C240 M5 ne samo savremenim, ve\u0107 i istinski naprednim. <\/p>\n<p>Hajde da vidimo \u0161ta dolazi u paketu. <\/p>\n<p><b>Sadr\u017eaj kutije<\/b>: server, KVM Dongle, dokumenti, disk, 2 kablova za napajanje, monta\u017eni komplet. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing rack server Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/4e6b39ebc4a78f8b37b29ea2d76da14e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nSkinimo poklopac. Pritiskamo, pomeramo i to je to. Nema alata i izgubljenih \u0161rafova. <br \/>\nOdmah upadaju u o\u010di zeleni oznake. Svi elementi koji podr\u017eavaju vru\u0107u zamenu ih imaju. Na primer, lako mo\u017eete zameniti ventilatore bez isklju\u010divanja napajanja celog servera. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing rack server Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/cb2fcaf627f96dd947421f65e80c2638.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nTako\u0111e vidimo velike re\u0161etke, ispod kojih se skrivaju novi procesori Intel Scal 2 Gen. Prime\u0107ujemo da je to do 56 jezgara na 2U serveru bez ikakvih problema sa hla\u0111enjem. Pored toga, podr\u017eava vi\u0161e memorije, do 1TB po procesoru. Podr\u017eana frekvencija memorije je tako\u0111e porasla na 2933 MHz. <\/p>\n<p>Pored CPU-a vidimo 24 slota za radnu memoriju - mo\u017eete koristiti module do 128 GB ili Intel Optane memoriju kapaciteta do 512 GB po slotu.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing rack server Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/147f87e31e346dbb0f360c92dccde512.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIntel Optane otvara pred nama neverovatne brzine obrade. Na primer, mo\u017ee se koristiti kao superbrzi lokalni SSD disk.<\/p>\n<p>Svakim danom sve vi\u0161e zahteva od klijenata po\u010dinje re\u010dima: \"\u017delim vi\u0161e diskova, vi\u0161e NVMe diskova u jednom sistemu.\" <\/p>\n<p>Na prednjoj strani imamo 8 2.5 in\u010dnih slotova za pohranu. Tako\u0111er je dostupan na narud\u017ebu model s standardnih 24 slota na prednjoj strani.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing rack server Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/ddeca4947e941f1dadfe2a691b8729d8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nOvisno o modifikaciji, u prvim slotovima mo\u017ee se instalirati do 8 NMVe diskova u U.2 formatu. <\/p>\n<p>Platforma C240 je vrlo popularna me\u0111u korisnicima koji se bave velikim podacima. Njihov glavni zahtjev je mogu\u0107nost kori\u0161tenja diskova za lokalno pokretanje, a po\u017eeljno je i hot pluggable.<\/p>\n<p>Odgovor na ovaj zahtjev bilo je rje\u0161enje Cisco-a u C240 M5, koje dodaje dva slota za diskove s podr\u0161kom za vru\u0107u zamjenu straga servera.<\/p>\n<p>Oni su smje\u0161teni desno od slotova za pro\u0161irenje do napajanja. Diskovi mogu biti bilo koji: SAS, SATA, SSD, NVMe.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing rack server Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/33ef5ba06667b6e130ce724bd27cf857.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nU blizini vidimo napajanja od 1600W. Tako\u0111er su hot pluggable i opremljena su zelenim oznakama.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing rack server Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/46ab4548bc3d84d497f772f7c8eaa633.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nZa rad s diskovnom podsistemom, u namjenski slot mo\u017ee se instalirati RAID kontroler od LSI s 2 GB ke\u0161a, ili HBA kartica za izravni prolaz.<\/p>\n<p>Na primjer, taj pristup se koristi prilikom izgradnje hiper-konvergentnog rje\u0161enja Cisco HyperFlex.<\/p>\n<p>Postoji druga\u010dija vrsta korisnika kojima diskovi uop\u0107e nisu potrebni. Ne \u017eele instalirati cijeli RAID kontroler za hipervizor, ali im se svi\u0111a 2U ku\u0107i\u0161te zbog prakti\u010dnosti odr\u017eavanja.<br \/>\nZa njih Cisco tako\u0111er ima rje\u0161enje.<\/p>\n<p>Predstavljam FlexFlash modul:<br \/>\nDve SD kartice, kapaciteta do 128 GB, s podr\u0161kom za mirroring, za instalaciju hipervizora, na primjer, VMware ESXi. Ovu opciju koristimo u ITGLOBAL.COM prilikom izgradnje vlastitih lokacija \u0161irom svijeta. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing rack server Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/d265c93e1e60428c69132b3cddb3a790.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nZa korisnike kojima je potrebno vi\u0161e prostora za pokretanje OS-a, postoji opcija modula s dva 'SATA' SSD diska u M.2 formatu, kapaciteta 240 ili 960 GB svaki. Po difoltu - ovo je softverski RAID. <\/p>\n<p>Za 240 GB diskove postoji opcija kori\u0161tenja Cisco Boot optimized M.2 RAID kontrolera - posebno hardverski RAID kontroler za ova dva SSD diska.<\/p>\n<p>Sve to podr\u017eavaju svi OS: i VMware i Windows, kao i razne Linux OS.<br \/>\nBroj PCI slotova - 6, \u0161to je karakteristi\u010dno za 2U platformu. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing rack server Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/67f57214e9f99cbad0add05865ed83f8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nUnutra ima dovoljno prostora. U servere se lako mo\u017ee instalirati dva puna grafi\u010dka akceleratora od NVidia, na primjer, TESLA M10 u projektima implementacije <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/bs\/vps\/abuzoustojchivye-vps\/\"   title=\"virtualnih radnih stolova\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"1009\">virtualnih radnih stolova<\/a> ili najnovija verzija V100 od 32GB za zadatke umjetne inteligencije. Njega \u0107emo iskoristiti u sljede\u0107em unboxing-u.<\/p>\n<p>Sa portovima situacija je sljede\u0107a: <\/p>\n<ul>\n<li>Konzolni port;<\/li>\n<li>Gigabitni posve\u0107eni upravlja\u010dki port;<\/li>\n<li>Dva porta USB 3.0;<\/li>\n<li>Integrisana 2-portna mre\u017ena kartica Intel x550 10Gb BASE-T;<\/li>\n<li>Opcionalna mLOM kartica, Cisco Vic 1387 dvostruki adapter od 40 GB.<\/li>\n<\/ul>\n<p>\nU mLOM utor mogu se instalirati samo Cisco VIC kartice, koje su efikasne za prenos LAN i SAN saobra\u0107aja. Kada se server koristi kao deo Cisco UCS fabrike, ovaj pristup omogu\u0107ava jedinstveno povezivanje sa LAN i SAN mre\u017eama bez potrebe za odvojenim FC adapterom. <\/p>\n<p>Hajde da instaliramo Nvidia V100 grafi\u010dku karticu. Uklanjamo drugi riser, skidamo poklopac, stavljamo karticu u PCI slot, zatvaramo plastiku i zatim poklopac. Priklju\u010dujemo dodatno napajanje. Prvo na karticu, zatim na riser. Vra\u0107amo riser na mesto. U su\u0161tini, sve ide lako bez kori\u0161\u0107enja alata. Brzo i precizno.<\/p>\n<p>U jednoj od narednih stavki prikaza\u0107emo njenu inicijalnu instalaciju. <\/p>\n<p>Tako\u0111e smo spremni da odgovorimo na sva pitanja <noindex><a rel=\"nofollow\" href=\"https:\/\/itglobal.com\/ru-ru\/solutions\/tech-partners\/cisco\/servers-unified-computing-system-ucs\/\">ovde<\/a><\/noindex> ili u komentarima.<br \/>\n<br \/>Izvor: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/itglobalcom\/blog\/467981\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435? \u0412\u043e-\u043f\u0435\u0440\u0432\u044b\u0445, \u0441\u0435\u0440\u0432\u0435\u0440\u044b Cisco \u0442\u0435\u043f\u0435\u0440\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u0432 Intel Scalable \u0432\u0442\u043e\u0440\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0412\u043e-\u0432\u0442\u043e\u0440\u044b\u0445, \u0442\u0435\u043f\u0435\u0440\u044c \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043c\u043e\u0434\u0443\u043b\u0438 Optane Memory \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u0430 NVMe-\u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":28746,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-38294","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/bs\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"bs_BA\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/bs\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Unboxing rack servera Cisco UCS C240 M5 | ProHoster","description":"Danas na na\u0161em stolu imamo novi rack server Cisco UCS C240 pete generacije. \u0160ta ga \u010dini zanimljivim za unboxing, s obzirom na to da je ovo ve\u0107 njegova peta generacija?","canonical_url":"https:\/\/prohoster.info\/bs\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"bs_BA","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster","og:description":"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?","og:url":"https:\/\/prohoster.info\/bs\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:22:48+00:00","article:modified_time":"2019-10-31T19:22:48+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"38294","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-02-09 13:06:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 01:12:21","updated":"2026-02-09 13:06:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/posts\/38294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/comments?post=38294"}],"version-history":[{"count":1,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/posts\/38294\/revisions"}],"predecessor-version":[{"id":158206,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/posts\/38294\/revisions\/158206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/media\/28746"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/media?parent=38294"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/categories?post=38294"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/bs\/wp-json\/wp\/v2\/tags?post=38294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}