{"id":38966,"date":"2019-10-31T22:27:03","date_gmt":"2019-10-31T19:27:03","guid":{"rendered":"https:\/\/prohoster.info\/blog\/admin-bez-ruk-giperkonvergentsiya\/"},"modified":"2019-10-31T22:27:03","modified_gmt":"2019-10-31T19:27:03","slug":"admin-bez-ruk-giperkonvergentsiya","status":"publish","type":"post","link":"https:\/\/prohoster.info\/cs\/blog\/administrirovanie\/admin-bez-ruk-giperkonvergentsiya","title":{"rendered":"Admin bez rukou = hyperkonvergence?","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Admin bez rukou = hyperkonvergence?\" src=\"\/wp-content\/uploads\/2019\/10\/ea1763132185c97bb4edf0e67640d58f.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<img decoding=\"async\" alt=\"Admin bez rukou = hyperkonvergence?\" src=\"\/wp-content\/uploads\/2019\/10\/b6355c444c310570e1f2619cd931e1ca.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nTo je m\u00fdtus, kter\u00fd je v oblasti serverov\u00e9ho hardwaru pom\u011brn\u011b roz\u0161\u00ed\u0159en\u00fd. V praxi v\u0161ak hyperkonvergentn\u00ed \u0159e\u0161en\u00ed (kdy\u017e je v\u0161e v jednom) jsou pot\u0159ebn\u00e1 z mnoha d\u016fvod\u016f. Historicky bylo prvn\u00ed architektury vyvinuto spole\u010dnostmi Amazon a Google pro sv\u00e9 slu\u017eby. Tehdy byla my\u0161lenka vytvo\u0159it v\u00fdpo\u010detn\u00ed farmu z identick\u00fdch uzl\u016f, z nich\u017e ka\u017ed\u00fd m\u011bl sv\u00e9 vlastn\u00ed disky. V\u0161e bylo spojeno n\u011bjak\u00fdm syst\u00e9mov\u00fdm softwarem (hypervizorem) a n\u00e1sledn\u011b rozd\u011blena na virtu\u00e1ln\u00ed stroje. Hlavn\u00edm c\u00edlem je minim\u00e1ln\u00ed \u00fasil\u00ed na \u00fadr\u017ebu jednoho uzlu a minim\u00e1ln\u00ed probl\u00e9my p\u0159i \u0161k\u00e1lov\u00e1n\u00ed: jednodu\u0161e se dokoupilo dal\u0161\u00ed tis\u00edcovku takov\u00fdch server\u016f a p\u0159ipojilo se vedle. V praxi se jedn\u00e1 o ojedin\u011bl\u00e9 p\u0159\u00edpady, a mnohem \u010dast\u011bji se hovo\u0159\u00ed o men\u0161\u00edm po\u010dtu uzl\u016f a trochu jin\u00e9 architektu\u0159e. <\/p>\n<p>Ale v\u00fdhoda z\u016fst\u00e1v\u00e1 stejn\u00e1 \u2013 neuv\u011b\u0159iteln\u00e1 jednoduchost \u0161k\u00e1lov\u00e1n\u00ed a spr\u00e1vy. Nev\u00fdhodou jsou r\u016fzn\u00e9 \u00fakoly, kter\u00e9 r\u016fzn\u011b spot\u0159ebov\u00e1vaj\u00ed zdroje, a n\u011bkde bude m\u00edstn\u00edch disk\u016f hodn\u011b, jinde m\u00e1lo RAM, a tak d\u00e1le, co\u017e znamen\u00e1, \u017ee p\u0159i r\u016fzn\u00fdch typech \u00fakol\u016f bude klesat vyu\u017eit\u00ed zdroj\u016f. <\/p>\n<p>Uk\u00e1zalo se, \u017ee plat\u00edte o 10-15 % v\u00edce za pohodl\u00ed v nastaven\u00ed. To vyvolalo m\u00fdtus, kter\u00fd je uveden v nadpisu. Dlouho jsme hledali, kde by technologie mohla b\u00fdt optim\u00e1ln\u011b aplikov\u00e1na, a na\u0161li jsme to. Skute\u010dnost je takov\u00e1, \u017ee Cisco nem\u011blo sv\u00e9 vlastn\u00ed \u00falo\u017ei\u0161t\u011b, ale cht\u011bli kompletn\u00ed serverov\u00fd trh. A vytvo\u0159ili Cisco Hyperflex \u2013 \u0159e\u0161en\u00ed s m\u00edstn\u00edmi \u00falo\u017ei\u0161ti na uzlech. <\/p>\n<p>A z toho n\u00e1hle vzniklo velmi dobr\u00e9 \u0159e\u0161en\u00ed pro z\u00e1lo\u017en\u00ed datov\u00e1 centra (Disaster Recovery). Pro\u010d a jak \u2013 nyn\u00ed v\u00e1m pov\u00edm. A uk\u00e1\u017eu testy clusteru. <noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<h3>Kde je to pot\u0159eba<\/h3>\n<p>\nHyperkonvergence \u2013 to je: <\/p>\n<ol>\n<li>P\u0159enos disk\u016f do v\u00fdpo\u010detn\u00edch uzl\u016f.<\/li>\n<li>Plnohodnotn\u00e1 integrace subsyst\u00e9mu ukl\u00e1d\u00e1n\u00ed dat se subsyst\u00e9mem virtualizace.<\/li>\n<li>P\u0159enos\/integrace s s\u00ed\u0165ov\u00fdm subsyst\u00e9mem.<\/li>\n<\/ol>\n<p>\nTakov\u00e9 propojen\u00ed umo\u017e\u0148uje implementaci mnoha funkc\u00ed \u00falo\u017ei\u0161t\u011b na \u00farovni virtualizace a to v\u0161e z jednoho ovl\u00e1dac\u00edho okna.<\/p>\n<p>V na\u0161\u00ed spole\u010dnosti jsou velmi \u017e\u00e1dan\u00e9 projekty na n\u00e1vrh z\u00e1lo\u017en\u00edch datov\u00fdch center, a \u010dasto se vol\u00ed pr\u00e1v\u011b hyperkonvergentn\u00ed \u0159e\u0161en\u00ed d\u00edky mno\u017estv\u00ed mo\u017enost\u00ed replikace (a\u017e po metroklaster) z krabice. <\/p>\n<p>V p\u0159\u00edpad\u011b z\u00e1lo\u017en\u00edch datov\u00fdch center se obvykle jedn\u00e1 o vzd\u00e1len\u00fd objekt na m\u00edst\u011b na druh\u00e9 stran\u011b m\u011bsta nebo dokonce v jin\u00e9m m\u011bst\u011b. To umo\u017e\u0148uje obnovit kritick\u00e9 syst\u00e9my v p\u0159\u00edpad\u011b \u010d\u00e1ste\u010dn\u00e9ho nebo \u00fapln\u00e9ho selh\u00e1n\u00ed hlavn\u00edho datov\u00e9ho centra. Data se neust\u00e1le replikuj\u00ed z produk\u010dn\u00edho prost\u0159ed\u00ed, a tato replikace m\u016f\u017ee prob\u00edhat na \u00farovni aplikace nebo na \u00farovni blokov\u00e9ho za\u0159\u00edzen\u00ed (\u00falo\u017ei\u0161t\u011b).<\/p>\n<p>Proto te\u010f pop\u00ed\u0161u strukturu syst\u00e9mu a testy, a pot\u00e9 - n\u011bkolik sc\u00e9n\u00e1\u0159\u016f re\u00e1ln\u00e9ho pou\u017eit\u00ed s \u00fadaji o \u00faspor\u00e1ch. <\/p>\n<h3>Testy<\/h3>\n<p>\nNa\u0161e instance se skl\u00e1d\u00e1 ze \u010dty\u0159 server\u016f, p\u0159i\u010dem\u017e ka\u017ed\u00fd z nich m\u00e1 10 SSD disk\u016f o velikosti 960 GB. Existuje vyhrazen\u00fd disk pro ke\u0161ov\u00e1n\u00ed z\u00e1pisov\u00fdch operac\u00ed a ukl\u00e1d\u00e1n\u00ed servisn\u00ed virtu\u00e1ln\u00ed ma\u0161iny. Samo \u0159e\u0161en\u00ed je \u010dtvrt\u00e1 verze. Prvn\u00ed byla o\u010dividn\u011b nedod\u011blan\u00e1 (soud\u011b podle recenz\u00ed), druh\u00e1 byla tak\u00e9 nedokonal\u00e1, t\u0159et\u00ed byla ji\u017e dost stabiln\u00ed, a tuto lze nazvat verz\u00ed po skon\u010den\u00ed beta testov\u00e1n\u00ed pro \u0161ir\u0161\u00ed ve\u0159ejnost. B\u011bhem testov\u00e1n\u00ed jsem nezjistil \u017e\u00e1dn\u00e9 probl\u00e9my, v\u0161e funguje jako hodinky.<\/p>\n<p><b class=\"spoiler_title\">Zm\u011bny ve verzi 4<\/b>Bylo opraveno mno\u017estv\u00ed chyb. <\/p>\n<p>P\u016fvodn\u011b platforma mohla pracovat pouze s hypervizorem VMware ESXi a podporovala omezen\u00fd po\u010det uzl\u016f. Tak\u00e9 proces nasazen\u00ed \u010dasto nekon\u010dil \u00fasp\u011b\u0161n\u011b, musel se restartovat n\u011bkter\u00e9 kroky, byly probl\u00e9my s aktualizac\u00ed ze star\u0161\u00edch verz\u00ed, data v GUI se nezobrazovala v\u017edy spr\u00e1vn\u011b (i kdy\u017e te\u010f nejsem nad\u0161en\u00fd z grafick\u00e9ho zobrazen\u00ed v\u00fdkonu), n\u011bkdy se objevovaly probl\u00e9my na pomez\u00ed s virtualizac\u00ed.<\/p>\n<p>Nyn\u00ed jsou v\u0161echny d\u011btsk\u00e9 nemoci opraveny, HyperFlex ovl\u00e1d\u00e1 jak ESXi, tak Hyper-V, nav\u00edc je mo\u017en\u00e9:<\/p>\n<ol>\n<li>Vytvo\u0159en\u00ed roz\u0161\u00ed\u0159en\u00e9ho clustru. <\/li>\n<li>Vytvo\u0159en\u00ed clustru pro kancel\u00e1\u0159e bez pou\u017eit\u00ed Fabric Interconnect, od dvou do \u010dty\u0159 uzl\u016f (kupujeme pouze servery).<\/li>\n<li>Mo\u017enost pr\u00e1ce s extern\u00edmi \u00falo\u017ei\u0161ti.<\/li>\n<li>Podpora kontejner\u016f a Kubernetes.<\/li>\n<li>Vytvo\u0159en\u00ed z\u00f3n dostupnosti.<\/li>\n<li>Integrace s VMware SRM, pokud integrovan\u00e1 funk\u010dnost nevyhovuje.<\/li>\n<\/ol>\n<p>Architektura se v\u00fdrazn\u011b neli\u0161\u00ed od \u0159e\u0161en\u00ed hlavn\u00edch konkurent\u016f, kolo jsme nevynalezli. V\u0161echno to funguje na virtualiza\u010dn\u00ed platform\u011b VMware nebo Hyper-V. Hardwarov\u011b je to um\u00edst\u011bno na serverech vlastn\u00ed konstrukce Cisco UCS. Jsou ti, kdo nen\u00e1vid\u00ed tuto platformu kv\u016fli relativn\u00ed slo\u017eitosti po\u010d\u00e1te\u010dn\u00edho nastaven\u00ed, mno\u017estv\u00ed tla\u010d\u00edtek, netradi\u010dn\u00edmu syst\u00e9mu \u0161ablon a z\u00e1vislost\u00ed, ale jsou i ti, kdo pochopili Zen, vc\u00edtili se do my\u0161lenky a necht\u011bj\u00ed u\u017e pracovat s jin\u00fdmi servery. <\/p>\n<p>Budeme se zab\u00fdvat pr\u00e1v\u011b \u0159e\u0161en\u00edm pro VMware, proto\u017ee bylo p\u016fvodn\u011b vytvo\u0159eno pro n\u011bj a m\u00e1 v\u011bt\u0161\u00ed funk\u010dnost; Hyper-V byl vylep\u0161en pr\u016fb\u011b\u017en\u011b, aby nez\u016fstal pozadu za konkurenc\u00ed a splnil o\u010dek\u00e1v\u00e1n\u00ed trhu.<\/p>\n<p>Existuje cluster server\u016f napln\u011bn\u00fdch disky. Jsou disky ur\u010den\u00e9 pro ukl\u00e1d\u00e1n\u00ed dat (SSD nebo HDD \u2014 podle va\u0161eho vkusu a pot\u0159eb), a jeden SSD disk pro cachov\u00e1n\u00ed. P\u0159i z\u00e1pisu dat na datastore doch\u00e1z\u00ed k ukl\u00e1d\u00e1n\u00ed dat na cache vrstv\u011b (vyhrazen\u00fd SSD disk a RAM servisn\u00ed VM). Paraleln\u011b je blok dat zas\u00edl\u00e1n na uzly v clusteru (po\u010det uzl\u016f z\u00e1vis\u00ed na faktoru replikace clusteru). Po potvrzen\u00ed od v\u0161ech uzl\u016f o \u00fasp\u011b\u0161n\u00e9m z\u00e1pisu je potvrzen\u00ed z\u00e1pisu odesl\u00e1no hypervizoru a d\u00e1le \u2014 do VM. Ulo\u017een\u00e1 data se na pozad\u00ed deduplikuje, komprimuj\u00ed a zapisuj\u00ed na \u00falo\u017en\u00e9 disky. P\u0159i tom se na \u00falo\u017en\u00e9 disky v\u017edy zapisuje velk\u00fd blok a postupn\u011b, co\u017e sni\u017euje z\u00e1t\u011b\u017e na \u00falo\u017en\u00e9 disky.<\/p>\n<p>Deduplicace a komprese jsou neust\u00e1le zapnuty a nelze je vypnout. \u010cten\u00ed dat prob\u00edh\u00e1 p\u0159\u00edmo z \u00falo\u017en\u00fdch disk\u016f nebo z cache RAM. Pokud je pou\u017eita hybridn\u00ed konfigurace, pak se \u010dten\u00ed tak\u00e9 cache na SSD disku.<\/p>\n<p>Data nejsou v\u00e1z\u00e1na na aktu\u00e1ln\u00ed um\u00edst\u011bn\u00ed virtu\u00e1ln\u00edho stroje a distribuuj\u00ed se mezi uzly rovnom\u011brn\u011b. Takov\u00fd p\u0159\u00edstup umo\u017e\u0148uje rovnom\u011brn\u011b zat\u00ed\u017eit v\u0161echny disky a s\u00ed\u0165ov\u00e9 rozhran\u00ed. Samoz\u0159ejm\u011b, \u017ee zde je z\u0159ejm\u00fd nedostatek: nem\u016f\u017eeme co nejv\u00edc sn\u00ed\u017eit zpo\u017ed\u011bn\u00ed \u010dten\u00ed, proto\u017ee nen\u00ed zaru\u010deno, \u017ee data jsou lok\u00e1ln\u00ed. Ale pova\u017euji to za zanedbatelnou ob\u011b\u0165 ve srovn\u00e1n\u00ed s dosa\u017een\u00fdmi v\u00fdhodami. O to v\u00edc, \u017ee latence v s\u00edti dos\u00e1hla takov\u00fdch hodnot, \u017ee prakticky neovliv\u0148uje celkov\u00fd v\u00fdsledek.<\/p>\n<p>Za celou logiku pr\u00e1ce diskov\u00e9ho subsyst\u00e9mu odpov\u00edd\u00e1 speci\u00e1ln\u00ed servisn\u00ed VM Cisco HyperFlex Data Platform controller, kter\u00e1 se vytv\u00e1\u0159\u00ed na ka\u017ed\u00e9 uzlu \u00falo\u017ei\u0161t\u011b. V na\u0161\u00ed konfiguraci byla servisn\u00ed VM p\u0159id\u011blena osm vCPU a 72 GB RAM, co\u017e nen\u00ed zrovna m\u00e1lo. P\u0159ipom\u00edn\u00e1m, \u017ee samotn\u00fd host m\u00e1 k dispozici 28 fyzick\u00fdch jader a 512 GB RAM.<\/p>\n<p>Servisn\u00ed VM m\u00e1 p\u0159\u00edstup k fyzick\u00fdm disk\u016fm p\u0159\u00edmo pomoc\u00ed pr\u016fchodu SAS-\u0159adi\u010de do VM. Komunikace s hypervizorem prob\u00edh\u00e1 prost\u0159ednictv\u00edm speci\u00e1ln\u00edho modulu IOVisor, kter\u00fd zachycuje operace vstupu a v\u00fdstupu, a pomoc\u00ed agenta, kter\u00fd umo\u017e\u0148uje p\u0159ed\u00e1vat p\u0159\u00edkazy do API hypervizoru. Agent zaji\u0161\u0165uje pr\u00e1ci s HyperFlex snapshoty a klony.<\/p>\n<p>V hypervizoru se diskov\u00e9 zdroje montuj\u00ed jako NFS- nebo SMB-sd\u00edlen\u00ed (z\u00e1vis\u00ed na typu hypervizoru, h\u00e1dejte, kter\u00fd je kde). A pod kapotou je to distribuovan\u00fd souborov\u00fd syst\u00e9m, kter\u00fd umo\u017e\u0148uje p\u0159id\u00e1n\u00ed funkc\u00ed dosp\u011bl\u00fdch plnohodnotn\u00fdch \u00falo\u017ei\u0161\u0165: tenk\u00e9 p\u0159id\u011blov\u00e1n\u00ed objem\u016f, kompresi a deduplikaci, snapshoty podle technologie Redirect-on-Write, synchronn\u00ed\/asynchronn\u00ed replikaci.<\/p>\n<p>Servisn\u00ed VM poskytuje p\u0159\u00edstup k webov\u00e9mu rozhran\u00ed spr\u00e1vy subsyst\u00e9mu HyperFlex. Existuje integrace s vCenter a v\u011bt\u0161ina ka\u017edodenn\u00edch \u00fakol\u016f m\u016f\u017ee b\u00fdt provedena z n\u011bj, ale datastory je nap\u0159\u00edklad pohodln\u011bj\u0161\u00ed rozd\u011blit z odd\u011blen\u00e9ho webov\u00e9ho rozhran\u00ed, pokud jste ji\u017e p\u0159e\u0161li na rychl\u00e9 HTML5 rozhran\u00ed, nebo pou\u017e\u00edt plnohodnotn\u00e9ho Flash klienta s kompletn\u00ed integrac\u00ed. V servisn\u00edm webov\u00e9m rozhran\u00ed lze sledovat v\u00fdkonnost a podrobn\u00fd stav syst\u00e9mu.<\/p>\n<p><img decoding=\"async\" alt=\"Admin bez rukou = hyperkonvergence?\" src=\"\/wp-content\/uploads\/2019\/10\/4f603b38d6489836892bebc76663eb2f.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nExistuje tak\u00e9 jin\u00fd typ uzl\u016f v klastru \u2014 v\u00fdpo\u010detn\u00ed uzly. To mohou b\u00fdt rackov\u00e9 nebo blade servery bez vestav\u011bn\u00fdch disk\u016f. Na t\u011bchto serverech lze spou\u0161t\u011bt VM, jejich\u017e data jsou ulo\u017eena na serverech s disky. Z pohledu p\u0159\u00edstupu k dat\u016fm nen\u00ed rozd\u00edl mezi typy uzl\u016f, proto\u017ee architektura p\u0159edpokl\u00e1d\u00e1 abstrakci od fyzick\u00e9ho um\u00edst\u011bn\u00ed dat. Maxim\u00e1ln\u00ed pom\u011br v\u00fdpo\u010detn\u00edch uzl\u016f a uzl\u016f \u00falo\u017ei\u0161t\u011b je 2:1.<\/p>\n<p>Pou\u017eit\u00ed v\u00fdpo\u010detn\u00edch uzl\u016f zvy\u0161uje flexibilitu p\u0159i \u0161k\u00e1lov\u00e1n\u00ed zdroj\u016f klastru: nemus\u00edme nutn\u011b dokupovat uzly s disky, pokud m\u00e1me pot\u0159ebu pouze po CPU\/RAM. Krom\u011b toho m\u016f\u017eeme p\u0159idat blade ko\u0161 a z\u00edskat \u00fasporu na um\u00edst\u011bn\u00ed server\u016f v racku.<\/p>\n<p>V\u00fdsledkem je, \u017ee m\u00e1me hyperkonvergentn\u00ed platformu s n\u00e1sleduj\u00edc\u00edmi funkcemi:<\/p>\n<ul>\n<li>A\u017e 64 uzl\u016f v clusteru (a\u017e 32 uzl\u016f pro ukl\u00e1d\u00e1n\u00ed).<\/li>\n<li>Minim\u00e1ln\u00ed po\u010det uzl\u016f v clusteru \u2014 t\u0159i (dva pro Edge cluster).<\/li>\n<li>Mekanismus redundance dat: zrcadlen\u00ed s replikac\u00ed 2 a 3.<\/li>\n<li>Metro cluster.<\/li>\n<li>Asynchronn\u00ed replikace VM na jin\u00fd HyperFlex cluster.<\/li>\n<li>Orchestrace p\u0159ep\u00edn\u00e1n\u00ed VM do vzd\u00e1len\u00e9ho datov\u00e9ho centra.<\/li>\n<li>Nativn\u00ed snapshoty pomoc\u00ed technologie Redirect-on-Write.<\/li>\n<li>A\u017e 1 PB u\u017eite\u010dn\u00e9ho prostoru p\u0159i replikaci 3 a bez zohledn\u011bn\u00ed deduplikace. Replikace 2 se nezohled\u0148uje, proto\u017ee to nen\u00ed varianta pro seri\u00f3zn\u00ed prodej.<\/li>\n<\/ul>\n<p>\nDal\u0161\u00ed obrovsk\u00e1 v\u00fdhoda \u2014 jednoduchost spr\u00e1vy a nasazen\u00ed. V\u0161echny slo\u017eitosti nastaven\u00ed server\u016f UCS p\u0159eb\u00edr\u00e1 specializovan\u00e1 VM, kterou p\u0159ipravili in\u017een\u00fd\u0159i Cisco. <\/p>\n<h3>Konfigurace testovac\u00edho stojanu:<\/h3>\n<p><\/p>\n<ul>\n<li>2 x Cisco UCS Fabric Interconnect 6248UP jako \u0159\u00edd\u00edc\u00ed cluster a s\u00ed\u0165ov\u00e9 komponenty (48 port\u016f pracuj\u00edc\u00edch v re\u017eimu Ethernet 10G\/FC 16G).<\/li>\n<li>\u010cty\u0159i servery Cisco UCS HXAF240 M4.<\/li>\n<\/ul>\n<p>\nSpecifikace server\u016f:<\/p>\n<p><\/p>\n<p>CPU<\/p>\n<p>2 x Intel \u00ae Xeon \u00ae E5-2690 v4<\/p>\n<p>RAM<\/p>\n<p>16 x 32GB DDR4-2400-MHz RDIMM\/PC4-19200\/dual rank\/x4\/1.2v<\/p>\n<p>S\u00ed\u0165<\/p>\n<p>UCSC-MLOM-CSC-02 (VIC 1227). 2 porty 10G Ethernet<\/p>\n<p>Storage HBA<\/p>\n<p>Cisco 12G Modular SAS Pass through Controller<\/p>\n<p>\u00dalo\u017en\u00e9 disky<\/p>\n<p>1 x SSD Intel S3520 120 GB, 1 x SSD Samsung MZ-IES800D, 10 x SSD Samsung PM863a 960 GB<\/p>\n<p>\n<b class=\"spoiler_title\">V\u00edce konfigurac\u00ed<\/b>Krom\u011b vybran\u00e9ho hardwaru jsou v sou\u010dasnosti k dispozici n\u00e1sleduj\u00edc\u00ed mo\u017enosti:<\/p>\n<ul>\n<li>HXAF240c M5.<\/li>\n<li>Jedno nebo dv\u011b CPU za\u010d\u00ednaj\u00edc\u00ed od Intel Silver 4110 a\u017e po Intel Platinum I8260Y. K dispozici je druh\u00e1 generace.<\/li>\n<li>24 slot\u016f pro pam\u011b\u0165, moduly od 16 GB RDIMM 2600 do 128 GB LRDIMM 2933.<\/li>\n<li>Od 6 do 23 disk\u016f pro data, jeden cache disk, jeden syst\u00e9mov\u00fd a jeden bootovac\u00ed disk.<\/li>\n<\/ul>\n<p>\n<b>Kapacitn\u00ed disky<\/b><\/p>\n<ul>\n<li>HX-SD960G61X-EV 960GB 2.5 palcov\u00fd Enterprise Value 6G SATA SSD (1X endurance) SAS 960 GB.<\/li>\n<li>HX-SD38T61X-EV 3.8TB 2.5 palcov\u00fd Enterprise Value 6G SATA SSD (1X endurance) SAS 3.8 TB.<\/li>\n<li>Cache disky<\/li>\n<li>HX-NVMEXPB-I375 375GB 2.5 palcov\u00fd Intel Optane Drive, Extreme Perf &amp; Endurance.<\/li>\n<li>HX-NVMEHW-H1600* 1.6TB 2.5 palcov\u00fd Ent. Perf. NVMe SSD (3X endurance) NVMe 1.6 TB.<\/li>\n<li>HX-SD400G12TX-EP 400GB 2.5 palcov\u00fd Ent. Perf. 12G SAS SSD (10X endurance) SAS 400 GB.<\/li>\n<li>HX-SD800GBENK9** 800GB 2.5 palcov\u00fd Ent. Perf. 12G SAS SED SSD (10X endurance) SAS 800 GB.<\/li>\n<li>HX-SD16T123X-EP 1.6TB 2.5 palcov\u00fd Enterprise performance 12G SAS SSD (3X endurance).<\/li>\n<\/ul>\n<p>\n<b>Syst\u00e9mov\u00e9 \/ Log disky<\/b><\/p>\n<ul>\n<li>HX-SD240GM1X-EV 240GB 2.5 palcov\u00fd Enterprise Value 6G SATA SSD (vy\u017eaduje upgrade).<\/li>\n<\/ul>\n<p>\n<b>Boot disky<\/b><\/p>\n<ul>\n<li>HX-M2-240GB 240GB SATA M.2 SSD SATA 240 GB.<\/li>\n<\/ul>\n<p>P\u0159ipojen\u00ed k s\u00edti pomoc\u00ed port\u016f Ethernet 40G, 25G nebo 10G. <\/p>\n<p>Jako FI mohou b\u00fdt HX-FI-6332 (40G), HX-FI-6332-16UP (40G), HX-FI-6454 (40G\/100G).<\/p>\n<h3>Samotn\u00fd test<\/h3>\n<p>\nPro testov\u00e1n\u00ed diskov\u00e9ho subsyst\u00e9mu jsem pou\u017eil HCIBench 2.2.1. Je to bezplatn\u00e1 utilita umo\u017e\u0148uj\u00edc\u00ed automatizaci vytv\u00e1\u0159en\u00ed z\u00e1t\u011b\u017ee z n\u011bkolika virtu\u00e1ln\u00edch stroj\u016f. Samotn\u00e1 z\u00e1t\u011b\u017e je generov\u00e1na b\u011b\u017en\u00fdm fio. <\/p>\n<p>N\u00e1\u0161 cluster se skl\u00e1d\u00e1 ze \u010dty\u0159 uzl\u016f, faktor replikace 3, v\u0161echny disky Flash.<\/p>\n<p>Pro testov\u00e1n\u00ed jsem vytvo\u0159il \u010dty\u0159i datov\u00e1 \u00falo\u017ei\u0161t\u011b a osm virtu\u00e1ln\u00edch stroj\u016f. Pro z\u00e1znamov\u00e9 testy se p\u0159edpokl\u00e1d\u00e1 varianta, kdy se vyrovn\u00e1vac\u00ed disk nep\u0159epl\u0148uje.<\/p>\n<p>V\u00fdsledky test\u016f jsou n\u00e1sleduj\u00edc\u00ed:<\/p>\n<p>100 % \u010cten\u00ed 100 % N\u00e1hodn\u011b<\/p>\n<p>0 % \u010cten\u00ed 100 % N\u00e1hodn\u011b<\/p>\n<p>Blok \/ hloubka fronty<\/p>\n<p>128<\/p>\n<p>256<\/p>\n<p>512<\/p>\n<p>1024<\/p>\n<p>2048<\/p>\n<p>128<\/p>\n<p>256<\/p>\n<p>512<\/p>\n<p>1024<\/p>\n<p>2048<\/p>\n<p>4K<\/p>\n<p>0,59 ms 213804 IOPS<\/p>\n<p>0,84 ms 303540 IOPS<\/p>\n<p>1,36 ms 374348 IOPS<\/p>\n<p>2,47 ms 414116 IOPS<\/p>\n<p><b>4,86 ms 420180 IOPS<\/b><\/p>\n<p>2,22 ms 57408 IOPS<\/p>\n<p>3,09 ms 82744 IOPS<\/p>\n<p>5,02 ms 101824 IOPS<\/p>\n<p>8,75 ms 116912 IOPS<\/p>\n<p><b>17,2 ms 118592 IOPS<\/b><\/p>\n<p>8K<\/p>\n<p>0,67 ms 188416 IOPS<\/p>\n<p>0,93 ms 273280 IOPS<\/p>\n<p>1,7 ms 299932 IOPS<\/p>\n<p>2,72 ms 376484 IOPS<\/p>\n<p><b>5,47 ms 373176 IOPS<\/b><\/p>\n<p>3,1 ms 41148 IOPS<\/p>\n<p>4,7 ms 54396 IOPS<\/p>\n<p>7,09 ms 72192 IOPS<\/p>\n<p><b>12,77 ms 80132 IOPS<\/b><\/p>\n<p>16K<\/p>\n<p>0,77 ms 164116 IOPS<\/p>\n<p>1,12 ms 228328 IOPS<\/p>\n<p>1,9 ms 268140 IOPS<\/p>\n<p><b>3,96 ms 258480 IOPS<\/b><\/p>\n<p>3,8 ms 33640 IOPS<\/p>\n<p>6,97 ms 36696 IOPS<\/p>\n<p><b>11,35 ms 45060 IOPS<\/b><\/p>\n<p>32K<\/p>\n<p>1,07 ms 119292 IOPS<\/p>\n<p>1,79 ms 142888 IOPS<\/p>\n<p><b>3,56 ms 143760 IOPS<\/b><\/p>\n<p>7,17 ms 17810 IOPS<\/p>\n<p><b>11,96 ms 21396 IOPS<\/b><\/p>\n<p>64K<\/p>\n<p>1,84 ms 69440 IOPS<\/p>\n<p>3,6 ms 71008 IOPS<\/p>\n<p><b>7,26 ms 70404 IOPS<\/b><\/p>\n<p><b>11,37 ms 11248 IOPS<\/b><\/p>\n<p><i>Tu\u010dn\u011b jsou ozna\u010deny hodnoty, po kter\u00fdch ji\u017e nedoch\u00e1z\u00ed k r\u016fstu v\u00fdkonu, ob\u010das je dokonce viditeln\u00e1 degradace. Je to zp\u016fsobeno t\u00edm, \u017ee jsme limitov\u00e1ni v\u00fdkonem s\u00edt\u011b \/ \u0159adi\u010d\u016f \/ disk\u016f.<\/i><\/p>\n<ul>\n<li>Sekven\u010dn\u00ed \u010dten\u00ed 4432 MB\/s.<\/li>\n<li>Sekven\u010dn\u00ed z\u00e1pis 804 MB\/s.<\/li>\n<li>Pokud sel\u017ee jeden \u0159adi\u010d (selh\u00e1n\u00ed virtu\u00e1ln\u00edho stroje nebo hostitele), v\u00fdkon kles\u00e1 na polovinu.<\/li>\n<li>P\u0159i selh\u00e1n\u00ed disku \u00falo\u017ei\u0161t\u011b doch\u00e1z\u00ed k poklesu o 1\/3. Obnova disku spot\u0159ebov\u00e1v\u00e1 5 % zdroj\u016f ka\u017ed\u00e9ho \u0159adi\u010de.<\/li>\n<\/ul>\n<p>\nU mal\u00e9ho bloku nar\u00e1\u017e\u00edme na v\u00fdkon \u0159adi\u010de (virtu\u00e1ln\u00ed stroj), jeho CPU je zat\u00ed\u017een na 100 %, p\u0159i zvy\u0161ov\u00e1n\u00ed bloku nar\u00e1\u017e\u00edme na propustnost port\u016f. 10 Gbit\/s nesta\u010d\u00ed k \u00fapln\u00e9mu vyu\u017eit\u00ed potenci\u00e1lu AllFlash syst\u00e9mu. Bohu\u017eel, testov\u00e1n\u00ed na 40 Gbit\/s nen\u00ed mo\u017en\u00e9 kv\u016fli parametr\u016fm poskytnut\u00e9ho demo standu.<\/p>\n<p>Podle m\u00fdch dojm\u016f z test\u016f a zkoum\u00e1n\u00ed architektury, d\u00edky algoritmu, kter\u00fd rozmis\u0165uje data mezi v\u0161emi hostiteli, z\u00edsk\u00e1v\u00e1me \u0161k\u00e1lovateln\u00fd a p\u0159edv\u00eddateln\u00fd v\u00fdkon, ale to je tak\u00e9 omezen\u00ed p\u0159i \u010dten\u00ed, proto\u017ee z lok\u00e1ln\u00edch disk\u016f by bylo mo\u017en\u00e9 vyt\u00e1hnout v\u00edce. Zde by mohla pomoci v\u00fdkonn\u011bj\u0161\u00ed s\u00ed\u0165, nap\u0159\u00edklad FI dostupn\u00e9 na 40 Gbit\/s.<\/p>\n<p>Tak\u00e9 jeden disk pro vyrovn\u00e1vac\u00ed pam\u011b\u0165 a deduplikaci m\u016f\u017ee b\u00fdt omezen\u00edm, v tomto standu skute\u010dn\u011b m\u016f\u017eeme zapisovat na \u010dty\u0159i SSD disky. Bylo by skv\u011bl\u00e9 m\u00edt mo\u017enost zvy\u0161ovat po\u010det vyrovn\u00e1vac\u00edch disk\u016f a vid\u011bt rozd\u00edl.<\/p>\n<h3>Skute\u010dn\u00e9 pou\u017eit\u00ed<\/h3>\n<p>\nPro zaji\u0161t\u011bn\u00ed z\u00e1lo\u017en\u00edho datov\u00e9ho centra lze pou\u017e\u00edt dva p\u0159\u00edstupy (um\u00edst\u011bn\u00ed z\u00e1lohy na vzd\u00e1len\u00e9m m\u00edst\u011b nezva\u017eujeme):<\/p>\n<ol>\n<li>Aktivn\u011b-pasivn\u00ed. V\u0161echny aplikace jsou um\u00edst\u011bny v hlavn\u00edm datov\u00e9m centru. Replikace je synchronn\u00ed nebo asynchronn\u00ed. V p\u0159\u00edpad\u011b v\u00fdpadku hlavn\u00edho datov\u00e9ho centra mus\u00edme aktivovat z\u00e1lo\u017en\u00ed. To lze prov\u00e9st ru\u010dn\u011b\/scripts\/aplikacemi orchestraci. Zde dostaneme RPO porovnateln\u00fd s frekvenc\u00ed replikace, a RTO z\u00e1vis\u00ed na reakci a schopnostech administr\u00e1tora a kvalit\u011b zpracov\u00e1n\u00ed\/debugov\u00e1n\u00ed pl\u00e1nu p\u0159epnut\u00ed.<\/li>\n<li>Aktivn\u011b-aktivn\u00ed. V tomto p\u0159\u00edpad\u011b je p\u0159\u00edtomna pouze synchronn\u00ed replikace, dostupnost datov\u00fdch center je ur\u010dena v\u011bt\u0161inou\/rozhod\u010d\u00edm um\u00edst\u011bn\u00fdm striktn\u011b na t\u0159et\u00ed lokalit\u011b. RPO = 0, a RTO m\u016f\u017ee dos\u00e1hnout 0 (pokud aplikace umo\u017e\u0148uje) nebo se rovn\u00e1 \u010dasu pot\u0159ebn\u00e9mu k p\u0159ekon\u00e1n\u00ed v\u00fdpadku uzlu v klastru virtualizace. Na \u00farovni virtualizace se vytv\u00e1\u0159\u00ed roz\u0161\u00ed\u0159en\u00fd (Metro) klastr, kter\u00fd vy\u017eaduje aktivn\u011b-aktivn\u00ed SDD.<\/li>\n<\/ol>\n<p>\nObvykle vid\u00edme, \u017ee z\u00e1kazn\u00edci ji\u017e maj\u00ed realizovanou architekturu s klasickou SDD v hlavn\u00edm datov\u00e9m centru, proto navrhujeme dal\u0161\u00ed pro replikaci. Jak jsem ji\u017e zm\u00ednil, Cisco HyperFlex nab\u00edz\u00ed asynchronn\u00ed replikaci a vytv\u00e1\u0159en\u00ed roz\u0161\u00ed\u0159en\u00e9ho klastru virtualizace. P\u0159itom nepot\u0159ebujeme specializovanou SDD st\u0159edn\u00ed \u00farovn\u011b a v\u00fd\u0161e s drah\u00fdmi funkcemi replikace a aktivn\u011b-aktivn\u00edho p\u0159\u00edstupu k dat\u016fm na dvou SDD.<\/p>\n<p><b>Sc\u00e9n\u00e1\u0159 1:<\/b> M\u00e1me hlavn\u00ed a z\u00e1lo\u017en\u00ed datov\u00e1 centra, platforma virtualizace na VMware vSphere. V\u0161echny produk\u010dn\u00ed syst\u00e9my jsou um\u00edst\u011bny v hlavn\u00edm datov\u00e9m centru, a replikace virtu\u00e1ln\u00edch stroj\u016f se prov\u00e1d\u00ed na \u00farovni hypervizoru, co\u017e umo\u017en\u00ed, \u017ee VM nemus\u00ed b\u00fdt zapnut\u00e9 v z\u00e1lo\u017en\u00edm datov\u00e9m centru. Datab\u00e1ze a speci\u00e1ln\u00ed aplikace replikujeme vestav\u011bn\u00fdmi prost\u0159edky a dr\u017e\u00edme VM zapnut\u00e9. V p\u0159\u00edpad\u011b v\u00fdpadku hlavn\u00edho datov\u00e9ho centra spou\u0161t\u00edme syst\u00e9my v z\u00e1lo\u017en\u00edm datov\u00e9m centru. P\u0159edpokl\u00e1d\u00e1me, \u017ee m\u00e1me kolem 100 virtu\u00e1ln\u00edch stroj\u016f. Dokud funguje hlavn\u00ed datov\u00e9 centrum, v z\u00e1lo\u017en\u00edm datov\u00e9m centru lze spou\u0161t\u011bt testovac\u00ed prost\u0159ed\u00ed a dal\u0161\u00ed syst\u00e9my, kter\u00e9 lze vypnout v p\u0159\u00edpad\u011b p\u0159epnut\u00ed hlavn\u00edho datov\u00e9ho centra. Tak\u00e9 je mo\u017en\u00e1 varianta, kdy m\u00e1me dvoucestnou replikaci. Z hlediska hardwaru se nic nezm\u011bn\u00ed.<\/p>\n<p>V p\u0159\u00edpad\u011b klasick\u00e9 architektury um\u00edst\u00edme do ka\u017ed\u00e9ho datov\u00e9ho centra hybridn\u00ed \u00falo\u017ei\u0161t\u011b s p\u0159\u00edstupem p\u0159es FibreChannel, tieringem, deduplikac\u00ed a kompres\u00ed (ale ne online), 8 server\u016f na ka\u017edou lokalitu, po 2 p\u0159ep\u00edna\u010de FibreChannel a Ethernet 10G. Pro replikaci a spr\u00e1vu p\u0159ep\u00edn\u00e1n\u00ed v klasick\u00e9 architektu\u0159e m\u016f\u017eeme pou\u017e\u00edt n\u00e1stroje VMware (Replication + SRM) nebo jin\u00e9 n\u00e1stroje, kter\u00e9 budou o n\u011bco levn\u011bj\u0161\u00ed a ob\u010das i pohodln\u011bj\u0161\u00ed.<\/p>\n<p>Na obr\u00e1zku je zn\u00e1zorn\u011bn diagram.<\/p>\n<p><img decoding=\"async\" alt=\"Admin bez rukou = hyperkonvergence?\" src=\"\/wp-content\/uploads\/2019\/10\/e7a1ef66c0ae1a8cbb60d0411007d822.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nV p\u0159\u00edpad\u011b pou\u017eit\u00ed Cisco HyperFlex vznik\u00e1 n\u00e1sleduj\u00edc\u00ed architektura:<\/p>\n<p><img decoding=\"async\" alt=\"Admin bez rukou = hyperkonvergence?\" src=\"\/wp-content\/uploads\/2019\/10\/71d58163728f37a163ec914b81dc73ab.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nPro HyperFlex jsem pou\u017eil servery s velk\u00fdmi zdroji CPU\/RAM, proto\u017ee \u010d\u00e1st zdroj\u016f p\u016fjde na VM kontroleru HyperFlex, po CPU a pam\u011bti jsem dokonce trochu p\u0159ezal\u017eil v konfiguraci HyperFlex, abych nevyhovoval Cisco a zajistil zdroje pro ostatn\u00ed VM. Zato se m\u016f\u017eeme vzd\u00e1t p\u0159ep\u00edna\u010d\u016f FibreChannel a nebudeme pot\u0159ebovat Ethernetov\u00e9 porty pro ka\u017ed\u00fd server, m\u00edstn\u00ed traffic se p\u0159ep\u00edn\u00e1 uvnit\u0159 FI.<\/p>\n<p>Nakonec vznikla n\u00e1sleduj\u00edc\u00ed konfigurace pro ka\u017ed\u00e9 datov\u00e9 centrum:<\/p>\n<p>Servery<\/p>\n<p>8 x 1U Server (384 GB RAM, 2 x Intel Gold 6132, FC HBA)<\/p>\n<p>8 x HX240C-M5L (512 GB RAM, 2 x Intel Gold 6150, 3,2 GB SSD, 10 x 6 TB NL-SAS)<\/p>\n<p>\u00dalo\u017ei\u0161t\u011b dat<\/p>\n<p>Hybridn\u00ed \u00falo\u017ei\u0161t\u011b s FC Front-End (20TB SSD, 130 TB NL-SAS)<\/p>\n<p>&#8212;<\/p>\n<p>LAN<\/p>\n<p>2 x Ethernet switch 10G 12 ports<\/p>\n<p>&#8212;<\/p>\n<p>SAN<\/p>\n<p>2 x FC switch 32\/16Gb 24 ports<\/p>\n<p>2 x Cisco UCS FI 6332<\/p>\n<p>Licence<\/p>\n<p>VMware Ent Plus<\/p>\n<p><\/p>\n<p>Replikace a\/nebo orchestrace p\u0159ep\u00edn\u00e1n\u00ed VM<\/p>\n<p>VMware Ent Plus<\/p>\n<p>Pro HyperFlex jsem nezakl\u00e1dal licence pro replika\u010dn\u00ed software, proto\u017ee to m\u00e1me dostupn\u00e9 z krabice.<\/p>\n<p>Pro klasickou architekturu jsem vybral dodavatele, kter\u00fd si vybudoval pov\u011bst kvalitn\u00edho a cenov\u011b dostupn\u00e9ho v\u00fdrobce. Pro ob\u011b varianty jsem pou\u017eil standardn\u00ed slevu pro dan\u00e9 \u0159e\u0161en\u00ed, na v\u00fdstupu jsem dostal re\u00e1ln\u00e9 ceny. <\/p>\n<p>\u0158e\u0161en\u00ed na Cisco HyperFlex vy\u0161lo o 13 % levn\u011bji.<\/p>\n<p><b>Sc\u00e9n\u00e1\u0159 2:<\/b> vytvo\u0159en\u00ed dvou aktivn\u00edch datov\u00fdch center. V tomto sc\u00e9n\u00e1\u0159i projektujeme roz\u0161\u00ed\u0159en\u00fd klastr na VMware. <\/p>\n<p>Klasick\u00e1 architektura se skl\u00e1d\u00e1 ze server\u016f virtualizace, SAN (protokol FC) a dvou \u00falo\u017ei\u0161\u0165, kter\u00e1 um\u00ed \u010d\u00edst a zapisovat na tom, kter\u00e9 jsou mezi nimi rozprost\u0159eny. Na ka\u017ed\u00e9m \u00falo\u017ei\u0161ti navrhujeme u\u017eite\u010dnou kapacitu pro lokalitu.<\/p>\n<p><img decoding=\"async\" alt=\"Admin bez rukou = hyperkonvergence?\" src=\"\/wp-content\/uploads\/2019\/10\/c3830f5bab128b724d94e727218b21b5.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n <br \/>\nU HyperFlex jednodu\u0161e vytvo\u0159\u00edme Stretch Cluster se stejn\u00fdm po\u010dtem uzl\u016f na obou lokalit\u00e1ch. V tomto p\u0159\u00edpad\u011b se pou\u017e\u00edv\u00e1 faktor replikace 2+2.<\/p>\n<p><img decoding=\"async\" alt=\"Admin bez rukou = hyperkonvergence?\" src=\"\/wp-content\/uploads\/2019\/10\/6351c830c3fba60dc4e71a9a4245ec6f.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n <br \/>\nVznikla n\u00e1sleduj\u00edc\u00ed konfigurace:<\/p>\n<p>Klasick\u00e1 architektura<\/p>\n<p>HyperFlex<\/p>\n<p>Servery<\/p>\n<p>16 x 1U Server (384 GB RAM, 2 x Intel Gold 6132, FC HBA, 2 x 10G NIC)<\/p>\n<p>16 x HX240C-M5L (512 GB RAM, 2 x Intel Gold 6132, 1,6 TB NVMe, 12 x 3,8 TB SSD, VIC 1387)<\/p>\n<p>\u00dalo\u017ei\u0161t\u011b dat<\/p>\n<p>2 x AllFlash \u00falo\u017ei\u0161t\u011b (150 TB SSD)<\/p>\n<p>&#8212;<\/p>\n<p>LAN<\/p>\n<p>4 x Ethernet switch 10G 24 ports<\/p>\n<p>&#8212;<\/p>\n<p>SAN<\/p>\n<p>4 x FC switch 32\/16Gb 24 ports<\/p>\n<p>4 x Cisco UCS FI 6332<\/p>\n<p>Licence<\/p>\n<p>VMware Ent Plus<\/p>\n<p>VMware Ent Plus<\/p>\n<p>Ve v\u0161ech v\u00fdpo\u010dtech jsem nezohled\u0148oval s\u00ed\u0165ovou infrastrukturu, n\u00e1klady na datov\u00e1 centra atd.: budou stejn\u00e9 pro klasickou architekturu i pro \u0159e\u0161en\u00ed na HyperFlex.<\/p>\n<p>Co se ceny t\u00fd\u010de, HyperFlex byl o 5 % dra\u017e\u0161\u00ed. Je t\u0159eba poznamenat, \u017ee u zdroj\u016f CPU\/RAM jsem pro Cisco zaznamenal nesoulad, proto\u017ee jsem v konfiguraci rovnom\u011brn\u011b vyplnil kan\u00e1ly \u0159adi\u010d\u016f pam\u011bti. Cena je o n\u011bco vy\u0161\u0161\u00ed, ale ne o mnoho, co\u017e jasn\u011b nazna\u010duje, \u017ee hyperkonvergence nemus\u00ed b\u00fdt \"hra\u010dka pro bohat\u00e9\" a m\u016f\u017ee konkurovat standardn\u00edmu p\u0159\u00edstupu k budov\u00e1n\u00ed datov\u00fdch center. M\u016f\u017ee to b\u00fdt tak\u00e9 zaj\u00edmav\u00e9 pro ty, kte\u0159\u00ed ji\u017e maj\u00ed servery Cisco UCS a odpov\u00eddaj\u00edc\u00ed infrastrukturu. <\/p>\n<p>Mezi v\u00fdhody z\u00edsk\u00e1me absenci n\u00e1klad\u016f na spr\u00e1vu SAN a SSSD, online kompresi a deduplikaci, jednotn\u00fd kontaktn\u00ed bod pro podporu (virtualizace, servery, co\u017e je tak\u00e9 SSSD), \u00fasporu m\u00edsta (ale ne ve v\u0161ech sc\u00e9n\u00e1\u0159\u00edch), zjednodu\u0161en\u00ed provozu.<\/p>\n<p>Pokud jde o podporu, z\u00edsk\u00e1v\u00e1te ji od jednoho dodavatele - Cisco. Pokud soud\u00edm podle zku\u0161enost\u00ed s servery Cisco UCS, l\u00edb\u00ed se mi, na HyperFlex jsem se nemusel obracet, v\u0161echno fungovalo. In\u017een\u00fd\u0159i rychle odpov\u00eddaj\u00ed a mohou \u0159e\u0161it nejen b\u011b\u017en\u00e9 probl\u00e9my, ale i slo\u017eit\u00e9 hrani\u010dn\u00ed p\u0159\u00edpady. N\u011bkdy se na n\u011b obrac\u00edm s ot\u00e1zkami: \"Lze to ud\u011blat takto, p\u0159ipojit toto?\" nebo \"Tady jsem n\u011bco nakonfiguroval a nechce to fungovat. Pomozte!\" - trp\u011bliv\u011b najdou pot\u0159ebn\u00e9ho pr\u016fvodce a uk\u00e1\u017eou na spr\u00e1vn\u00e9 kroky, neodpov\u00ed: \"\u0158e\u0161\u00edme pouze hardwarov\u00e9 probl\u00e9my.\"<\/p>\n<h3>Odkazy<\/h3>\n<p><\/p>\n<ul>\n<li><noindex><a rel=\"nofollow\" href=\"https:\/\/www.cisco.com\/c\/dam\/en\/us\/products\/collateral\/hyperconverged-infrastructure\/hyperflex-hx-series\/hxaf-240c-m5-specsheet.pdf\">Specifikace<\/a><\/noindex><\/li>\n<li><noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/croc\/blog\/146536\/\">Virtu\u00e1ln\u00ed datov\u00e9 centrum<\/a><\/noindex><\/li>\n<li><noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/croc\/blog\/342820\/\">Datov\u00e9 centrum v \u0161upl\u00edku<\/a><\/noindex><\/li>\n<li>M\u016fj email je StGeneralov@croc.ru<\/li>\n<\/ul>\n<p>Zdroj: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/croc\/blog\/471508\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u042d\u0442\u043e \u043c\u0438\u0444, \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0451\u043d\u043d\u044b\u0439 \u0432 \u0441\u0444\u0435\u0440\u0435 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u043e\u0433\u043e \u0436\u0435\u043b\u0435\u0437\u0430. \u041d\u0430 \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0435 \u0436\u0435 \u0433\u0438\u043f\u0435\u0440\u043a\u043e\u043d\u0432\u0435\u0440\u0433\u0435\u043d\u0442\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f (\u043a\u043e\u0433\u0434\u0430 \u0432\u0441\u0451 \u0432 \u043e\u0434\u043d\u043e\u043c) \u043d\u0443\u0436\u043d\u044b \u043c\u043d\u043e\u0433\u043e \u0434\u043b\u044f \u0447\u0435\u0433\u043e. \u0418\u0441\u0442\u043e\u0440\u0438\u0447\u0435\u0441\u043a\u0438 \u0441\u043b\u043e\u0436\u0438\u043b\u043e\u0441\u044c, \u0447\u0442\u043e \u043f\u0435\u0440\u0432\u044b\u0435 \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u044b \u0431\u044b\u043b\u0438 \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u044b Amazon \u0438 Google \u043f\u043e\u0434 \u0441\u0432\u043e\u0438 \u0441\u0435\u0440\u0432\u0438\u0441\u044b. \u0422\u043e\u0433\u0434\u0430 \u0438\u0434\u0435\u044f \u0431\u044b\u043b\u0430 \u0432 \u0442\u043e\u043c, \u0447\u0442\u043e\u0431\u044b \u0441\u0434\u0435\u043b\u0430\u0442\u044c \u0432\u044b\u0447\u0438\u0441\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u0443\u044e \u0444\u0435\u0440\u043c\u0443 \u0438\u0437 \u043e\u0434\u0438\u043d\u0430\u043a\u043e\u0432\u044b\u0445 \u0443\u0437\u043b\u043e\u0432, \u0443 \u043a\u0430\u0436\u0434\u043e\u0433\u043e \u0438\u0437 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0435\u0441\u0442\u044c \u0441\u043e\u0431\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u0434\u0438\u0441\u043a\u0438. \u0412\u0441\u0451 \u044d\u0442\u043e [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":29233,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-38966","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.3 - aioseo.com -->\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/cs\/blog\/administrirovanie\/admin-bez-ruk-giperkonvergentsiya\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"cs_CZ\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0410\u0434\u043c\u0438\u043d \u0431\u0435\u0437 \u0440\u0443\u043a = \u0433\u0438\u043f\u0435\u0440\u043a\u043e\u043d\u0432\u0435\u0440\u0433\u0435\u043d\u0446\u0438\u044f? | ProHoster\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/cs\/blog\/administrirovanie\/admin-bez-ruk-giperkonvergentsiya\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:27:03+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:27:03+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Admin bez rukou = hyperkonvergence? | ProHoster","description":"","canonical_url":"https:\/\/prohoster.info\/cs\/blog\/administrirovanie\/admin-bez-ruk-giperkonvergentsiya","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"cs_CZ","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0410\u0434\u043c\u0438\u043d \u0431\u0435\u0437 \u0440\u0443\u043a = \u0433\u0438\u043f\u0435\u0440\u043a\u043e\u043d\u0432\u0435\u0440\u0433\u0435\u043d\u0446\u0438\u044f? | ProHoster","og:url":"https:\/\/prohoster.info\/cs\/blog\/administrirovanie\/admin-bez-ruk-giperkonvergentsiya","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:27:03+00:00","article:modified_time":"2019-10-31T19:27:03+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"38966","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-24 00:12:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 00:59:27","updated":"2026-01-24 00:12:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/posts\/38966","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/comments?post=38966"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/posts\/38966\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/media\/29233"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/media?parent=38966"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/categories?post=38966"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/tags?post=38966"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}