{"id":56401,"date":"2020-02-12T00:00:00","date_gmt":"2020-02-11T21:00:00","guid":{"rendered":"https:\/\/prohoster.info\/blog\/blog_prohoster\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit"},"modified":"2020-02-18T14:04:41","modified_gmt":"2020-02-18T11:04:41","slug":"besperebojniki-apc-smart-ups-i-kak-ih-gotovit","status":"publish","type":"post","link":"https:\/\/prohoster.info\/cs\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","title":{"rendered":"Nep\u0159eru\u0161iteln\u00e9 zdroje APC Smart UPS a jak je p\u0159ipravit","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Mezi \u0161irok\u00fdm rozmanit\u00fdm sortimentem UPS jsou nejb\u011b\u017en\u011bj\u0161\u00ed pro servery na \u00farovni vstupn\u00edch za\u0159\u00edzen\u00ed UPS zna\u010dky APC (nyn\u00ed \u2013 Schneider Electric). Skv\u011bl\u00e1 spolehlivost a n\u00edzk\u00e1 cena na sekund\u00e1rn\u00edm trhu zp\u016fsobuj\u00ed, \u017ee administr\u00e1to\u0159i, ani\u017e by se zvl\u00e1\u0161\u0165 zam\u00fd\u0161leli, um\u00eds\u0165uj\u00ed do polic tyto UPS a sna\u017e\u00ed se vyt\u00e1hnout z hardware star\u00e9ho 10-15 let maxim\u00e1ln\u00ed zisk pouhou v\u00fdm\u011bnou bateri\u00ed. Bohu\u017eel to ne v\u017edy p\u0159in\u00e1\u0161\u00ed o\u010dek\u00e1van\u00e9 v\u00fdsledky. Pokusme se zjistit, co a jak d\u011blat, aby v\u00e1\u0161 UPS fungoval \u201ejako nov\u00fd\u201c.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<h3>V\u00fdb\u011br bateri\u00ed<\/h3>\n<p>\nV\u0161echny \u010dl\u00e1nky a t\u00e9mata na f\u00f3rech o v\u00fdb\u011bru bateri\u00ed pro UPS nej\u010dast\u011bji p\u0159ipom\u00ednaj\u00ed diskuse o v\u00fdb\u011bru motorov\u00e9ho oleje pro auta\/motocykly. Pokusme se nepod\u00e1vat identick\u00fd p\u0159\u00edstup a pochopit z\u00e1kladn\u00ed principy v\u00fdb\u011bru bateri\u00ed na p\u0159\u00edkladu v\u00fdrobce CSB. <\/p>\n<p>Vid\u00edme u nich spoustu r\u016fzn\u00fdch \u0159ad bateri\u00ed: GP, GPL, HR, HRL, UPS, TPL. <\/p>\n<p>Za\u010d\u00edn\u00e1me \u010d\u00edst: GP, GPL \u2014 baterie univerz\u00e1ln\u00edho pou\u017eit\u00ed <b>pro mal\u00e9 a st\u0159edn\u00ed vyb\u00edjec\u00ed proudy.<\/b>Jsou doporu\u010dov\u00e1ny pro pou\u017eit\u00ed v zabezpe\u010dovac\u00edch a po\u017e\u00e1rn\u00edch syst\u00e9mech a UPS. N\u00e1m nevyhovuj\u00ed. A\u010dkoliv je pr\u00e1v\u011b kupuj\u00ed nej\u010dast\u011bji, ani\u017e by se dostate\u010dn\u011b sezn\u00e1mili s jejich charakteristikami. <\/p>\n<p><img decoding=\"async\" alt=\"Nep\u0159eru\u0161iteln\u00e9 zdroje APC Smart UPS a jak je p\u0159ipravit\" src=\"\/wp-content\/uploads\/2020\/02\/8daafaf7943d755075773d981e84d94c.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nS\u00e9rie HR \u2014 baterie s vy\u0161\u0161\u00ed energetickou kapacitou, kter\u00e9 umo\u017e\u0148uj\u00ed hlubok\u00e9 vybit\u00ed (a\u017e 11% zbytkov\u00e9 kapacity), jsou zvl\u00e1\u0161\u0165 u\u017eite\u010dn\u00e9 p\u0159i pot\u0159eb\u011b vysok\u00fdch vyb\u00edjec\u00edch proud\u016f. Hlavn\u00ed odli\u0161nost bateri\u00ed \u201eH\u201c spo\u010d\u00edv\u00e1 ve specializovan\u00e9 konstrukci m\u0159\u00ed\u017eky, kter\u00e1 umo\u017e\u0148uje zv\u00fd\u0161it v\u00fdstupn\u00ed v\u00fdkon o 20%. Tyto baterie jsou nejl\u00e9pe vhodn\u00e9 pro pou\u017eit\u00ed ve v\u00fdkonn\u00fdch energetick\u00fdch instalac\u00edch a UPS.<\/p>\n<p>P\u00edsmeno \u201eL\u201c v s\u00e9rii nazna\u010duje, \u017ee se jedn\u00e1 o baterie s prodlou\u017eenou \u017eivotnost\u00ed (Long Life) v re\u017eimu bufferov\u00e9ho provozu a\u017e 10 let.<\/p>\n<p>A s\u00e9rie UPS \u2014 to jsou speci\u00e1ln\u011b vyvinut\u00e9 baterie pro provoz v re\u017eimech vysok\u00fdch proud\u016f p\u0159i kr\u00e1tk\u00fdch \u010dasech vyb\u00edjen\u00ed.<\/p>\n<p>Pro sebe jsem dlouho vyb\u00edral mezi UPS a HRL, ale rozhodl jsem se vz\u00edt HRL. Bohu\u017eel \u2013 o tom, jak se budou chovat p\u0159i dlouh\u00e9 pr\u00e1ci, lze \u0159\u00edct a\u017e za 5 let, a nekropostov\u00e1n\u00ed z\u0159ejm\u011b nen\u00ed p\u0159\u00edli\u0161 v\u00edt\u00e1no. Proto budeme pova\u017eovat, \u017ee to je m\u016fj osobn\u00ed v\u00fdb\u011br a nenut\u00edm v\u00e1s k n\u011bmu. Ale m\u011bli byste m\u00edt na pam\u011bti, \u017ee je nutn\u00e9 vyb\u00edrat vysokopr\u00fadov\u00e9 baterie, proto\u017ee mus\u00ed b\u00fdt schopny vydat cel\u00e9 \u043d\u0430\u043a\u043e\u043f\u043b\u0435\u043d\u043d\u0443\u044e kapacitu b\u011bhem 20-30 minut. <\/p>\n<h3>V\u00fdb\u011br mont\u00e1\u017ee bateri\u00ed<\/h3>\n<p>\nVzhledem k tomu, \u017ee se ve sestav\u011b pou\u017e\u00edv\u00e1 n\u011bkolik bateri\u00ed, je velmi \u017e\u00e1douc\u00ed, aby m\u011bly stejn\u00e9 vlastnosti. Proto\u017ee jeden \u0161patn\u00fd akumul\u00e1tor zp\u016fsob\u00ed, \u017ee cel\u00e1 sestava nebude fungovat tak, jak se o\u010dek\u00e1v\u00e1.<\/p>\n<p>P\u0159ed asi 5 lety jsem objevil rostovskou spole\u010dnost \u00abBastion\u00bb, kter\u00e1 vyr\u00e1b\u00ed testery kapacity bateri\u00ed pod obchodn\u00ed zna\u010dkou \u00abSkat\u00bb. Nechci tvrdit, \u017ee m\u011b\u0159en\u00ed kapacity je ide\u00e1ln\u011b p\u0159esn\u00e9, ale pro posouzen\u00ed \u00farovn\u011b: ide\u00e1ln\u00ed-\u017eiv\u00fd-je\u0161t\u011b poslou\u017e\u00ed-mrtv\u00fd, je tento tester v\u00edce ne\u017e dostate\u010dn\u00fd. <\/p>\n<p><img decoding=\"async\" alt=\"Nep\u0159eru\u0161iteln\u00e9 zdroje APC Smart UPS a jak je p\u0159ipravit\" src=\"\/wp-content\/uploads\/2020\/02\/7390b5c6865ebe74998c6d6494c4e548.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nV z\u00e1sad\u011b lze m\u011b\u0159it kapacitu oby\u010dejn\u00fdm nab\u00edjen\u00edm-vyb\u00edjen\u00edm s pou\u017eit\u00edm hodin, automobilov\u00e9 \u017e\u00e1rovky na 21W (ta vytv\u00e1\u0159\u00ed zat\u00ed\u017een\u00ed kolem 1A) a testeru, ale trv\u00e1 to dlouho a v\u011bt\u0161inou se n\u00e1m do toho nechce.<\/p>\n<p>Pokud to nezabere, prost\u011b se sna\u017e\u00edme d\u00e1vat nov\u00e9 akumul\u00e1tory ze stejn\u00e9 \u0161ar\u017ee a doufat, \u017ee budete m\u00edt \u0161t\u011bst\u00ed. <\/p>\n<h3>Elekt\u0159ina je v\u011bda o kontaktech.<\/h3>\n<p>\nJedna \u0161patn\u00e1 kontakti v sestav\u011b \u010dty\u0159 akumul\u00e1tor\u016f zma\u0159\u00ed ve\u0161ker\u00e9 va\u0161e \u00fasil\u00ed, proto rozeb\u00edr\u00e1me sestavu velmi opatrn\u011b. Obvykle se v UPS pou\u017e\u00edvaj\u00ed konektory pro akumul\u00e1tory s pojistkami, kter\u00e9 se jednoduch\u00fdm vyta\u017een\u00edm tak\u00e9 snadno zni\u010d\u00ed. Proto si vezmeme mal\u00fd ploch\u00fd \u0161roubov\u00e1k, vlo\u017e\u00edme do konektoru, jak je na fotografii, a opatrn\u011b ho odstran\u00edme, ani\u017e bychom vynalo\u017eili zvl\u00e1\u0161tn\u00ed \u00fasil\u00ed. Jak nazna\u010dil kolega v koment\u00e1\u0159i \u2014 je pot\u0159eba vytahovat pouze za plastov\u00fd obal, a ne za kabel. Konektor se odstran\u00ed s lehk\u00fdm cvaknut\u00edm.<\/p>\n<p><img decoding=\"async\" alt=\"Nep\u0159eru\u0161iteln\u00e9 zdroje APC Smart UPS a jak je p\u0159ipravit\" src=\"\/wp-content\/uploads\/2020\/02\/07d704acf5b9c5a92b2ddf6e05f89f2a.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nOhledn\u011b spr\u00e1vn\u00e9ho propojen\u00ed vodi\u010d\u016f bych si myslel, \u017ee je zbyte\u010dn\u00e9 ps\u00e1t. Pokud jste \u0161li dovnit\u0159 UPS, jasn\u011b v\u00e1m je zn\u00e1m princip s\u00e9riov\u00e9ho spojen\u00ed bateri\u00ed. A pro ostatn\u00ed: pap\u00edr-psac\u00ed pot\u0159eby nebo smartphone s kamerou. Po dokon\u010den\u00ed sestavy pro ka\u017ed\u00fd p\u0159\u00edpad m\u011b\u0159\u00edme testerem nap\u011bt\u00ed na sestav\u011b a porovn\u00e1v\u00e1me s t\u00edm, kter\u00e9 by m\u011blo b\u00fdt podle po\u010dtu akumul\u00e1tor\u016f.<\/p>\n<h3>\u201eUd\u011blal jsem v\u0161e, jak je naps\u00e1no, ale nepomohlo to\u201c<\/h3>\n<p>\nA te\u010f za\u010d\u00edn\u00e1 to nejzaj\u00edmav\u011bj\u0161\u00ed. UPS v procesu sv\u00e9 pr\u00e1ce pravideln\u011b (obvykle jednou za 7 nebo 14 dn\u00ed, v z\u00e1vislosti na nastaven\u00ed) prov\u00e1d\u00ed kr\u00e1tkou kalibraci baterie. P\u0159epne se do re\u017eimu provozu na baterie a m\u011b\u0159\u00ed nap\u011bt\u00ed okam\u017eit\u011b a po kr\u00e1tk\u00e9 dob\u011b. V\u00fdsledkem tohoto procesu je ur\u010dit\u00fd korek\u010dn\u00ed koeficient \u201e\u017eivotnosti baterie\u201c, kter\u00fd si zap\u00ed\u0161e do registru. B\u011bhem postupn\u00e9ho vyhas\u00edn\u00e1n\u00ed baterie se stav tohoto registru postupn\u011b sni\u017euje. Na jeho z\u00e1klad\u011b UPS vypo\u010d\u00edt\u00e1v\u00e1 zb\u00fdvaj\u00edc\u00ed dobu provozu na baterie. A v ur\u010dit\u00e9m okam\u017eiku, kdy\u017e si uv\u011bdom\u00ed, \u017ee n\u011bco nen\u00ed v po\u0159\u00e1dku, rozsv\u00edt\u00ed indik\u00e1tor se \u017e\u00e1dost\u00ed o v\u00fdm\u011bnu baterie. Ale kdy\u017e prov\u00e1d\u00edme v\u00fdm\u011bnu, UPS o tom nev\u00ed! Stav registru \u201e\u017eivotnosti baterie\u201c z\u016fst\u00e1v\u00e1 stejn\u00fd. Mus\u00edme ho opravit.<\/p>\n<p>Existuj\u00ed dv\u011b cesty. Prvn\u00ed, jednoduch\u00e1 a rychl\u00e1, je prov\u00e9st \u00faplnou kalibraci UPS. K tomu je t\u0159eba zat\u00ed\u017eit jej v\u00edce ne\u017e na 35 % a spustit kalibraci, nap\u0159\u00edklad z aplikace PowerChute. To funguje p\u0159ibli\u017en\u011b v polovin\u011b p\u0159\u00edpad\u016f. Pro\u010d ne v\u017edy \u2013 to je tajemstv\u00ed zahalen\u00e9 rou\u0161kou. Proto se vyd\u00e1me na del\u0161\u00ed, ale spolehliv\u011bj\u0161\u00ed cestu.<\/p>\n<p>Budeme pot\u0159ebovat: po\u010d\u00edta\u010d s COM portem, origin\u00e1ln\u00ed kabel (nap\u0159\u00edklad 940-0024C), program UpsDiag 2.0 (pro bezpe\u010dnost va\u0161eho UPS kolega doporu\u010duje l\u00e9pe pou\u017e\u00edt apcfix v bezplatn\u00e9m re\u017eimu. Nic nemohu \u0159\u00edci k t\u00e9to z\u00e1le\u017eitosti krom\u011b toho, \u017ee d\u016frazn\u011b nedoporu\u010duji v UpsDiag stisknout n\u011bco krom\u011b \u00fapravy registru 0. <i>zejm\u00e9na tla\u010d\u00edtko automatick\u00e9 opravy chyby baterie<\/i>) a <noindex><a rel=\"nofollow\" href=\"http:\/\/www.apcupsd.com\/manual\/manual.html#configuring-your-eeprom\">tabulka kalibra\u010dn\u00edch hodnot<\/a><\/noindex>. Zaj\u00edmaj\u00ed n\u00e1s hodnoty registru 0. V tabulce je uvedena hodnota pro ide\u00e1ln\u00ed, kulovit\u00e9 baterie ve vakuu. Jak\u00e9koli skute\u010dn\u00e9 baterie po kalibraci daj\u00ed ni\u017e\u0161\u00ed hodnotu, ale ne p\u0159\u00edli\u0161.<\/p>\n<p><img decoding=\"async\" alt=\"Nep\u0159eru\u0161iteln\u00e9 zdroje APC Smart UPS a jak je p\u0159ipravit\" src=\"\/wp-content\/uploads\/2020\/02\/93542115e332bece7803efac1c88a284.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nJako p\u0159\u00edklad vezmu skute\u010dn\u00fd UPS SUA1500RMI2U. V dob\u011b v\u00fdm\u011bny baterie ukazoval UpsDiag hodnotu registru 0 \u2013 42. To znamen\u00e1, \u017ee baterie je mrtv\u00e1. Kalibra\u010dn\u00ed hodnota v tabulce je A1. <\/p>\n<p>Za\u010d\u00edn\u00e1me s opravou. Nejprve <b>odstran\u00edme s\u00ed\u0165ovou kartu z UPS<\/b>. P\u0159\u00edtomnost s\u00ed\u0165ov\u00e9 karty v\u00e1m nedovol\u00ed upravit registr. Pro\u010d \u2013 to je ot\u00e1zka pro in\u017een\u00fdry APC. Na\u0161t\u011bst\u00ed ji lze vyjmout za b\u011bhu, ani\u017e byste museli vypnout UPS. <\/p>\n<p>P\u0159ipoj\u00edme kabel, spust\u00edme UpsDiag, p\u0159ejdeme na z\u00e1lo\u017eku \u201eKalibrace\u201c a zkontrolujeme stav registru 0. Zap\u00ed\u0161eme si to na pap\u00edr, klikneme na n\u011bj prav\u00fdm tla\u010d\u00edtkem my\u0161i \u2013 Upravit. Zvedneme jej na hodnotu z tabulky kalibra\u010dn\u00edch hodnot \u2013 A1. Pokud v\u00e1\u0161 UPS nen\u00ed v tabulce, v podstat\u011b jej lze zv\u00fd\u0161it a\u017e na FF. Nen\u00ed s t\u00edm \u017e\u00e1dn\u00fd probl\u00e9m, krom\u011b p\u0159ekvapen\u00e9ho UPS, kter\u00fd uk\u00e1\u017ee, \u017ee je p\u0159ipraven n\u00e9st z\u00e1t\u011b\u017e a\u017e do druh\u00e9ho p\u0159\u00edchodu. <\/p>\n<p>Pot\u00e9 mus\u00edme po\u010dkat, a\u017e se AKB nabije na 100 %, zat\u00ed\u017eit UPS na 35 % nebo trochu v\u00edce a spustit kalibraci. Po dokon\u010den\u00ed kalibrace znovu zkontrolujeme hodnotu v registru 0 a porovn\u00e1me ji s t\u00edm, co jsme si napsali. U v\u00fd\u0161e zm\u00edn\u011bn\u00e9ho SUA1500RMI2U s nov\u00fdmi akumul\u00e1tory HRL1234W se hodnota ust\u00e1lila na 98, co\u017e je v podstat\u011b docela bl\u00edzko kalibra\u010dn\u00ed hodnot\u011b A1.<\/p>\n<p>Po v\u0161em nech\u00e1me znovu nab\u00edt na 100 %, vyt\u00e1hneme COM kabel, znovu zapneme s\u00ed\u0165ovou kartu a p\u0159ejeme UPS dlouh\u00fd a \u0161\u0165astn\u00fd \u017eivot ku prosp\u011bchu na\u0161eho serverov\u00e9ho stojanu.<\/p>\n<p>Mimochodem, s\u00ed\u0165ov\u00e9 karty typu AP9619 tak\u00e9 na sekund\u00e1rn\u00edm trhu klesly na nep\u0159\u00edstojn\u00e9 ceny. Ale jak je p\u0159ipravit (resetov\u00e1n\u00ed hesla, aktualizace firmwaru, nastaven\u00ed) \u2013 to je t\u00e9ma na samostatn\u00fd \u010dl\u00e1nek.<br \/>\n<br \/>Zdroj: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/487802\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric). \u0412\u0435\u043b\u0438\u043a\u043e\u043b\u0435\u043f\u043d\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0438\u0437\u043a\u0430\u044f \u0446\u0435\u043d\u0430 \u043d\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u043c \u0440\u044b\u043d\u043a\u0435, \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u044e\u0442 \u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u0441\u0438\u0441\u0430\u0434\u043c\u0438\u043d\u044b, \u043e\u0441\u043e\u0431\u043e \u043d\u0435 \u0437\u0430\u0434\u0443\u043c\u044b\u0432\u0430\u044f\u0441\u044c, \u0443\u0442\u044b\u043a\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u043e\u0439\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u043c\u0438 \u0418\u0411\u041f \u0438 \u043f\u044b\u0442\u0430\u044e\u0442\u0441\u044f \u0432\u044b\u0442\u044f\u043d\u0443\u0442\u044c \u0441 \u0436\u0435\u043b\u0435\u0437\u043e\u043a 10-15 \u043b\u0435\u0442\u043d\u0435\u0439 \u0434\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0443\u043c \u043f\u0440\u043e\u0444\u0438\u0442\u0430 \u0431\u0430\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u043e\u0439 \u0430\u043a\u043a\u0443\u043c\u0443\u043b\u044f\u0442\u043e\u0440\u043e\u0432. \u041a \u0441\u043e\u0436\u0430\u043b\u0435\u043d\u0438\u044e \u043d\u0435 \u0432\u0441\u0435\u0433\u0434\u0430 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-56401","post","type-post","status-publish","format-standard","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.3 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/cs\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"cs_CZ\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/cs\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-02-11T21:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-02-18T11:04:41+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47UPS APC Smart UPS a jak je p\u0159ipravit | ProHoster","description":"Mezi celou \u0159adou UPS pat\u0159\u00ed mezi nejroz\u0161\u00ed\u0159en\u011bj\u0161\u00ed v serverov\u00fdch za\u0159\u00edzen\u00edch ni\u017e\u0161\u00ed \u00farovn\u011b Smart UPS od firmy APC (nyn\u00ed \u2013 Schneider Electric).","canonical_url":"https:\/\/prohoster.info\/cs\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"cs_CZ","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster","og:description":"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).","og:url":"https:\/\/prohoster.info\/cs\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-02-11T21:00:00+00:00","article:modified_time":"2020-02-18T11:04:41+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"56401","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 19:25:39","updated":"2022-09-29 13:07:34","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/posts\/56401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/comments?post=56401"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/posts\/56401\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/media?parent=56401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/categories?post=56401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/cs\/wp-json\/wp\/v2\/tags?post=56401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}