{"id":35321,"date":"2019-10-31T22:03:38","date_gmt":"2019-10-31T19:03:38","guid":{"rendered":"https:\/\/prohoster.info\/blog\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod\/"},"modified":"2019-10-31T22:03:38","modified_gmt":"2019-10-31T19:03:38","slug":"kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod","status":"publish","type":"post","link":"https:\/\/prohoster.info\/da\/blog\/administrirovanie\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod","title":{"rendered":"Kabinetter, moduler eller blokke \u2013 hvad skal man v\u00e6lge til str\u00f8mstyring i datacentre?","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Kabinetter, moduler eller blokke \u2013 hvad skal man v\u00e6lge til str\u00f8mstyring i datacentre?\" src=\"\/wp-content\/uploads\/2019\/06\/a6e891f08c0ebddac7c7b465fc404858.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<p>Moderne datacentre kr\u00e6ver en omhyggelig tilgang til str\u00f8mforsyning. Det er n\u00f8dvendigt samtidig at overv\u00e5ge belastningernes tilstand og styre tilslutningen af udstyr. Dette kan g\u00f8res ved at bruge skabe, moduler eller str\u00f8ddelingsenheder. Hvilken type energiforsyning der passer bedst til specifikke situationer, fort\u00e6ller vi i vores indl\u00e6g ved at bruge eksempler fra Delta-l\u00f8sninger.<\/p>\n<p><noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<p>Str\u00f8mforsyningen til et dynamisk voksende datacenter viser sig ofte at v\u00e6re en udfordrende opgave. Yderligere enheder i rackene, skift af udstyr til dvaletilstand eller omvendt en stigning i belastningen f\u00f8rer til ubalance i str\u00f8mforsyningen, stigende reaktiv effekt og suboptimal drift af det elektriske net. For at undg\u00e5 tab, sikre effektiv drift af udstyr og beskytte det mod potentielle str\u00f8mforsyningsproblemer, hj\u00e6lper systemer til str\u00f8ddeling.<\/p>\n<p><\/p>\n<p>Ved design af elektrisk forsyningsnet st\u00e5r it-specialister ofte over for valget mellem skabe, moduler og str\u00f8ddelingsenheder. I princippet l\u00f8ser alle tre kategorier af enheder de samme opgaver, men p\u00e5 forskellige niveauer og med forskellige s\u00e6t af muligheder.<\/p>\n<p><\/p>\n<h2>Str\u00f8ddelingsskab<\/h2>\n<p><\/p>\n<p>Str\u00f8ddelingsskabet, eller PDC (power distribution cabinet), er en enhed til kontrol af str\u00f8mforsyning p\u00e5 det \u00f8verste niveau. Skabet muligg\u00f8r balansering af str\u00f8mforsyningen for dusinvis af racks i datacentret, og brugen af flere skabe giver mulighed for at overv\u00e5ge driften af store datacentre. For eksempel, s\u00e5danne l\u00f8sninger anvendes af mobiloperat\u00f8rer \u2013 for at forsyne et datacenter med 5000 racks kr\u00e6vede det mere end 50 str\u00f8ddelingsskabe, <noindex><a rel=\"nofollow\" href=\"https:\/\/www.deltapowersolutions.com\/ru-ru\/mcis\/success-story-delta-power-distribution-cabinets-serve-china-mobile-shanghai.php\">installeret i datacentret China Mobile<\/a><\/noindex> i Shanghai.<\/p>\n<p><\/p>\n<p>Delta InfraSuite PDC-kabinettet, som har dimensioner svarende til et standard 19-tommers skab, indeholder to grupper af enpolet automatiske afbrydere, beskyttet af ekstra afbrydere. Kabinettet kan overv\u00e5ge str\u00f8mparametrene for hver enkelt kreds med en separat afbryder. Str\u00f8mfordelingskabinettet har et indbygget n\u00f8dsystem til at advare om ulige belastning. Som en valgmulighed kan Delta-kabinetterne udstyres med ekstra transformatorer til generering af forskellige udgangssp\u00e6ndinger samt moduler til beskyttelse mod impulsst\u00f8j, for eksempel fra lynnedslag. <\/p>\n<p><\/p>\n<p>Til kontrol kan man bruge den indbyggede LCD-sk\u00e6rm samt eksterne energistyringssystemer, der tilsluttes via en RS232 seriel interface eller via SNMP. Tilslutningen af enheden til et ekstern netv\u00e6rk sker gennem en s\u00e6rlig InsightPower-modul. Dette g\u00f8r det muligt at sende alarmer, kontrolpanelets data og tilstand parametre til centralserveren. Det er den prim\u00e6re komponent, der muligg\u00f8r fjernstyring og overv\u00e5gning samt informerer systemingeni\u00f8rer om kritiske begivenheder via SNMP-f\u00e6lde og e-mail.<\/p>\n<p><\/p>\n<p>Specialister, der betjener datacentre, kan finde ud af, hvilken fase der er mest belastet, og omdirigere nogle af forbrugerne til mindre belastede faser eller planl\u00e6gge installation af ekstra udstyr i tide. P\u00e5 sk\u00e6rmen kan man overv\u00e5ge parametre som temperatur, jordfejlstr\u00f8m og tilstedev\u00e6relsen eller frav\u00e6ret af sp\u00e6ndingsbalance. Systemet indeholder en log, der gemmer op til 500 h\u00e6ndelsesoptegnelser fra kabinettet, hvilket g\u00f8r det muligt at genskabe den n\u00f8dvendige konfiguration eller analysere fejlene forud for et n\u00f8dstop.<\/p>\n<p><\/p>\n<p>N\u00e5r det kommer til Delta-modellerne, tilsluttes PDC'en til et tredjfase-netv\u00e6rk og kan arbejde med en sp\u00e6nding p\u00e5 220 V med en afvigelse p\u00e5 h\u00f8jst 15 %. I serien findes modeller med en kapacitet p\u00e5 80 kVA og 125 kVA.<\/p>\n<p><\/p>\n<h2>Str\u00f8mfordelingsmoduler<\/h2>\n<p><\/p>\n<p>Hvis str\u00f8mfordelingsskabet er et separat skab, der kan flyttes rundt i datacenteret i tilf\u00e6lde af ombygning eller \u00e6ndringer i belastningsplaceringen, tillader modul\u00e6re systemer lignende udstyr at blive placeret direkte i rackene. De kaldes RPDC (Rack Power Distribution Cabinet) og er sm\u00e5 fordelingsskabe, der optager 4U i et standardrack. S\u00e5danne l\u00f8sninger bruges af internetvirksomheder, der har brug for garanteret drift af et lille udstyrspark. For eksempel er fordelingsmoduler blevet installeret som en del af en omfattende l\u00f8sning til beskyttelse af datacenteret. <noindex><a rel=\"nofollow\" href=\"https:\/\/www.deltapowersolutions.com\/ru-ru\/mcis\/success-story-delta-infrasuite-ensures-the-continuous-operation-of-an-online-shop-in-germany.php\">en af de f\u00f8rende internetbutikker<\/a><\/noindex> i Tyskland.<\/p>\n<p><\/p>\n<p>N\u00e5r man taler om Delta-udstyr, kan kapaciteten for en enhed RPDC v\u00e6re 30, 50 eller 80 kVA. Flere moduler kan installeres i et rack for at sikre str\u00f8mforsyning til alle belastninger i et mindre datacenter, eller man kan placere et RPDC i forskellige racks. Den sidste mulighed er velegnet til kraftige servere, som kr\u00e6ver kontrol med str\u00f8mtilf\u00f8rsel og omfordeling af str\u00f8m afh\u00e6ngigt af konfiguration og belastning. <\/p>\n<p><\/p>\n<p>En fordel ved det modul\u00e6re system er muligheden for at \u00f8ge kapaciteten i takt med v\u00e6ksten og skaleringen af datacenteret. Brugere v\u00e6lger ofte RPDC, n\u00e5r et komplet skab skaber for stort overskud i forhold til den nuv\u00e6rende konfiguration af 2-3 racks med udstyr.<\/p>\n<p><\/p>\n<p>Hver modul leveres med en touchsk\u00e6rm, der har stort set de samme kontrolmuligheder som en separat PDC, og underst\u00f8tter RS-232 gr\u00e6nseflader og smartkort til fjernstyring. Fordelingsmodulerne overv\u00e5ger str\u00f8mmen i hver tilsluttet kreds, informerer automatisk om n\u00f8dsituationer og underst\u00f8tter hot-swapping af afbrydere. Data om systemets tilstand gemmes i en log, der kan opbevare op til 2.000 poster.<\/p>\n<p><\/p>\n<h2>Str\u00f8mfordelingsenheder<\/h2>\n<p><\/p>\n<p>Str\u00f8mfordelingsenhederne er de mest kompakte og \u00f8konomiske systemer i denne kategori. De giver mulighed for at overv\u00e5ge driften af udstyret inden for et enkelt rack og tilbyder information om tilstanden af linjer og belastning. For eksempel er s\u00e5danne enheder blevet brugt til at udstyre <noindex><a rel=\"nofollow\" href=\"https:\/\/www.deltapowersolutions.com\/ru-ru\/mcis\/success-story-delta-develops-a-tailored-total-solution-for-miran-companys-data-center-in-st-petersburg.php\">datacenteret 'Miran'.<\/a><\/noindex>\u00bb i Sankt Petersborg og <noindex><a rel=\"nofollow\" href=\"https:\/\/www.deltapowersolutions.com\/ru-ru\/mcis\/success-story-delta-installs-infrastructure-solutions-at-the-russian-digital-enterprise-consortium.php\">erfarings-demonstrationscenter<\/a><\/noindex> af konsortiet \u00abDigitale virksomhed\u00bb i Tjeljabinsk.<\/p>\n<p><\/p>\n<p>Blokke findes i forskellige formater, men modeller, der er udf\u00f8rt med Zero-U teknologi, placeres i den samme rack som det prim\u00e6re udstyr, men optager ikke separate \u00abenheder\u00bb \u2013 de monteres vertikalt eller horisontalt p\u00e5 konstruktionselementer ved hj\u00e6lp af specielle beslag. Det vil sige, at hvis du bruger et rack p\u00e5 42U, vil du efter installation af blokken have netop s\u00e5 mange enheder tilbage. Hver fordelingsblok har sit eget alarmsystem: LED-indikatorer informerer om belastning eller n\u00f8dsituationer p\u00e5 hver af de afg\u00e5ende ledninger. Delta-blokke har en RS232-gr\u00e6nseflade og forbindes til overv\u00e5gningssystemer via SNMP, ligesom skabe og moduler til str\u00f8mfordeling.<\/p>\n<p><\/p>\n<p>M\u00f8demoduler og basis fordelingsblokke kan installeres direkte i rack, b\u00e5de i standard Delta-konstruktion og i racks fra andre producenter. Dette er muligt takket v\u00e6re et universelt s\u00e6t beslag. Str\u00f8mfordelingsblokke kan installeres vertikalt og horisontalt og anvendes ved forsyning af elektricitet fra enfasede og trefasede netv\u00e6rk. Den maksimale str\u00f8m for Delta fordelingsblokke er 32 A, med indgangssp\u00e6nding afvigelser p\u00e5 op til 10 %. Der kan v\u00e6re 6 eller 12 stik til tilslutning af belastningen.<\/p>\n<p><\/p>\n<h2>Det vigtigste er at skabe et omfattende ledelsessystem<\/h2>\n<p><\/p>\n<p>Valget mellem kabinet, blok eller modul afh\u00e6nger af, hvilken belastning der skal tilsluttes. I store datacentre er fordelingsskabe n\u00f8dvendige, hvilket dog ikke udelukker installation af yderligere moduler eller blokke til afledning af str\u00f8m til separate belastninger. <\/p>\n<p><\/p>\n<p>I mellemstore serverrum er det ofte tilstr\u00e6kkeligt med en eller to fordelingsmoduler. Fordelen ved denne l\u00f8sning er, at antallet af moduler kan \u00f8ges i takt med, at str\u00f8msystemet skaleres sammen med datacentrets udvikling.<\/p>\n<p><\/p>\n<p>I separate racks install distribution units, which will be sufficient for equipping a small server room. With a unified management system, they also allow monitoring and control of energy consumption, but do not enable dynamic redistribution of lines and hot swapping of contact elements and relays.<\/p>\n<p><\/p>\n<p>In modern data centers, you can simultaneously find cabinets, modules, and power distribution units installed at different times and for different purposes. The main goal is to integrate all equipment for energy supply management into a single monitoring system. This will allow for the control of any deviations in power supply parameters and take prompt measures: replacing equipment, expanding capacity, or redistributing loads to other lines\/phases. This can be done using software such as Delta InfraSuite or a similar product.<\/p>\n<p class=\"for_users_only_msg\">Kun registrerede brugere kan deltage i unders\u00f8gelsen. <noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/auth\/login\/\">Log ind<\/a><\/noindex>, please.<\/p>\n<h2 class=\"default-block__polling-title\">Do you use energy management systems in your network?<\/h2>\n<ul class=\"content-list content-list_polling\">\n<li class=\"content-list__item content-list__item_polling\">\n<p>                    Cabinets<\/p>\n<\/li>\n<li class=\"content-list__item content-list__item_polling\">\n<p>                    Moduler<\/p>\n<\/li>\n<li class=\"content-list__item content-list__item_polling\">\n<p>                    Units<\/p>\n<\/li>\n<li class=\"content-list__item content-list__item_polling\">\n<p>                    Nej<\/p>\n<\/li>\n<\/ul>\n<p>    7 brugere har stemt. 2 brugere afholdt sig.<br \/>\n<br \/>Kilde: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/delta\/blog\/455976\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0446\u0435\u043d\u0442\u0440\u044b \u043e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u0445 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0432\u043d\u0438\u043c\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0430 \u043a \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043f\u0438\u0442\u0430\u043d\u0438\u044e. \u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043e\u0434\u043d\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u043e\u0442\u0441\u043b\u0435\u0436\u0438\u0432\u0430\u0442\u044c \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u0442\u044c \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. \u0421\u0434\u0435\u043b\u0430\u0442\u044c \u044d\u0442\u043e \u043c\u043e\u0436\u043d\u043e, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044f \u043a\u0430\u0431\u0438\u043d\u0435\u0442\u044b, \u043c\u043e\u0434\u0443\u043b\u0438 \u0438\u043b\u0438 \u0431\u043b\u043e\u043a\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u043f\u0438\u0442\u0430\u043d\u0438\u044f. \u041e \u0442\u043e\u043c, \u043a\u0430\u043a\u043e\u0439 \u0442\u0438\u043f \u044d\u043d\u0435\u0440\u0433\u043e\u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043b\u0443\u0447\u0448\u0435 \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0445 \u0441\u0438\u0442\u0443\u0430\u0446\u0438\u0439, \u043c\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u043c \u0432 \u043d\u0430\u0448\u0435\u043c \u043f\u043e\u0441\u0442\u0435 \u043d\u0430 \u043f\u0440\u0438\u043c\u0435\u0440\u0430\u0445 \u0440\u0435\u0448\u0435\u043d\u0438\u0439 Delta. \u042d\u043d\u0435\u0440\u0433\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u0435 \u0434\u0438\u043d\u0430\u043c\u0438\u0447\u043d\u043e \u0440\u0430\u0437\u0432\u0438\u0432\u0430\u044e\u0449\u0435\u0433\u043e\u0441\u044f \u0426\u041e\u0414 \u0447\u0430\u0441\u0442\u043e \u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442\u0441\u044f \u043d\u0435\u043f\u0440\u043e\u0441\u0442\u043e\u0439 \u0437\u0430\u0434\u0430\u0447\u0435\u0439. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":26514,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-35321","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.3 - aioseo.com -->\n\t<meta name=\"description\" content=\".\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/da\/blog\/administrirovanie\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"da_DK\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u041a\u0430\u0431\u0438\u043d\u0435\u0442\u044b, \u043c\u043e\u0434\u0443\u043b\u0438 \u0438\u043b\u0438 \u0431\u043b\u043e\u043a\u0438 \u2013 \u0447\u0442\u043e \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043f\u0438\u0442\u0430\u043d\u0438\u0435\u043c \u0432 \u0426\u041e\u0414? | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\".\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/da\/blog\/administrirovanie\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:03:38+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:03:38+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Cabinets, modules, or units \u2013 what to choose for power management in data centers? | ProHoster","description":".","canonical_url":"https:\/\/prohoster.info\/da\/blog\/administrirovanie\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"da_DK","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u041a\u0430\u0431\u0438\u043d\u0435\u0442\u044b, \u043c\u043e\u0434\u0443\u043b\u0438 \u0438\u043b\u0438 \u0431\u043b\u043e\u043a\u0438 \u2013 \u0447\u0442\u043e \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043f\u0438\u0442\u0430\u043d\u0438\u0435\u043c \u0432 \u0426\u041e\u0414? | ProHoster","og:description":".","og:url":"https:\/\/prohoster.info\/da\/blog\/administrirovanie\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:03:38+00:00","article:modified_time":"2019-10-31T19:03:38+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"35321","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-21 22:47:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 02:06:23","updated":"2026-01-21 22:47:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/posts\/35321","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/comments?post=35321"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/posts\/35321\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/media\/26514"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/media?parent=35321"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/categories?post=35321"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/tags?post=35321"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}