{"id":56401,"date":"2020-02-12T00:00:00","date_gmt":"2020-02-11T21:00:00","guid":{"rendered":"https:\/\/prohoster.info\/blog\/blog_prohoster\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit"},"modified":"2020-02-18T14:04:41","modified_gmt":"2020-02-18T11:04:41","slug":"besperebojniki-apc-smart-ups-i-kak-ih-gotovit","status":"publish","type":"post","link":"https:\/\/prohoster.info\/da\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","title":{"rendered":"APC Smart UPS underholdningssystemer, og hvordan man forbereder dem","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Bland det store udvalg af UPS er de mest udbredte i entry-level serverrum Smart UPS fra APC (nu Schneider Electric). Den fantastiske p\u00e5lidelighed og den lave pris p\u00e5 det sekund\u00e6re marked g\u00f8r, at systemadministratorer uden at t\u00e6nke over det placerer disse UPS i racks og fors\u00f8ger at f\u00e5 maksimum profit fra hardware, der er 10-15 \u00e5r gammel, ved simpelthen at udskifte batterierne. Desv\u00e6rre giver dette ikke altid det \u00f8nskede resultat. Lad os finde ud af, hvad der skal g\u00f8res for at f\u00e5 din UPS til at fungere \"som ny.\"<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<h3>Valg af batterier<\/h3>\n<p>\nAlle artikler og emner p\u00e5 fora om valg af batterier til UPS minder oftest om emner om valg af motorolie til biler\/motorcykler. Lad os undg\u00e5 at blive ligesom dem, og i stedet forst\u00e5 de grundl\u00e6ggende principper for valg af batterier ved at tage producenten CSB som eksempel. <\/p>\n<p>Vi ser, at de har en masse forskellige serier af batterier: GP, GPL, HR, HRL, UPS, TPL. <\/p>\n<p>Vi begynder at l\u00e6se: GP, GPL - batterier til universelt brug <b>til sm\u00e5 og mellemstore afladningsstr\u00f8mme.<\/b>. Anbefales til brug i sikkerheds- og brandalarmsystemer og UPS. De passer ikke til os. Det er dog pr\u00e6cis disse, der oftest k\u00f8bes uden at deres specifikationer unders\u00f8ges. <\/p>\n<p><img decoding=\"async\" alt=\"APC Smart UPS underholdningssystemer, og hvordan man forbereder dem\" src=\"\/wp-content\/uploads\/2020\/02\/8daafaf7943d755075773d981e84d94c.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nHR-serien - batterier med h\u00f8j kapacitet, der tillader dyb afladning (op til 11% resterende kapacitet), er s\u00e6rligt nyttige, n\u00e5r der er behov for h\u00f8je afladningsstr\u00f8mme. Forskellen ved \"H\"-batterierne er en speciel gitterkonstruktion, der g\u00f8r det muligt at \u00f8ge den udgangseffekt med 20%. De er bedst egnet til brug i kraftige energianl\u00e6g og UPS.<\/p>\n<p>Brev \u00abL\u00bb i serien indikerer, at dette er batterier med forl\u00e6nget levetid (Long Life) i bufferdrift op til 10 \u00e5r.<\/p>\n<p>Og s\u00e5 er UPS-serien - det er specielt udviklede batterier til brug ved h\u00f8je str\u00f8mme i kort tidsramme.<\/p>\n<p>Jeg valgte l\u00e6nge mellem UPS og HRL, men besluttede at tage HRL. Desv\u00e6rre kan jeg ikke sige, hvordan de vil opf\u00f8re sig ved langvarig drift f\u00f8r om fem \u00e5r, og necro-posting er vist ikke s\u00e6rlig velset. Derfor vil jeg betragte dette som mit personlige valg, og jeg har ikke til hensigt at p\u00e5tvinge det. Men I skal forst\u00e5, at det er n\u00f8dvendigt at v\u00e6lge h\u00f8jstr\u00f8msbatterier, da de skal kunne afgive al den opsamlede kapacitet i l\u00f8bet af 20-30 minutter. <\/p>\n<h3>Udv\u00e6lgelse af sammens\u00e6tning af batterier<\/h3>\n<p>\nN\u00e5r flere batterier bruges i en samling, er det meget \u00f8nskeligt, at de har ensartede egenskaber. En fejlbeh\u00e6ftet batteri vil medf\u00f8re, at hele samlingen ikke fungerer som forventet.<\/p>\n<p>For omkring 5 \u00e5r siden opdagede jeg det Rostov-baserede firma \"Bastion\", der producerer batterikapacitetstestere under varem\u00e6rket \"Skat\". Jeg vil ikke p\u00e5st\u00e5, at m\u00e5lingerne er perfekt n\u00f8jagtige, men til vurdering af tilstanden: ideel - levende - stadig brugbar - d\u00f8d er denne tester mere end tilstr\u00e6kkelig. <\/p>\n<p><img decoding=\"async\" alt=\"APC Smart UPS underholdningssystemer, og hvordan man forbereder dem\" src=\"\/wp-content\/uploads\/2020\/02\/7390b5c6865ebe74998c6d6494c4e548.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nMan kan i princippet m\u00e5le kapaciteten ved simpelthen at oplade og aflade med et ur, en 21W bilp\u00e6re (den giver belastning omkring 1A) og en tester, men det er tidskr\u00e6vende og ofte for mageligt.<\/p>\n<p>I n\u00f8dsituation kan vi blot fors\u00f8ge at anvende friske batterier fra samme parti og h\u00e5be, at vi er heldige. <\/p>\n<h3>Elektricitet er videnskaben om kontakter.<\/h3>\n<p>\nEn d\u00e5rlig kontakt i en samling af 4 batterier vil annullere alt dit arbejde, s\u00e5 vi skal h\u00e5ndtere samlingen meget omhyggeligt. I UPS'er bruges der ofte stik til batterier med l\u00e5se, som ved simpel udtr\u00e6kning nemt kan \u00f8del\u00e6gges. Derfor tager vi en lille flad skruetr\u00e6kker, inds\u00e6tter den i stikket som vist p\u00e5 billedet, og fjerner det forsigtigt uden at yde for stort et pres. Som en kollega foreslog i kommentaren \u2014 man skal blot tr\u00e6kke i det plastikhus, ikke i ledningen. Stikket fjernes med et let klik.<\/p>\n<p><img decoding=\"async\" alt=\"APC Smart UPS underholdningssystemer, og hvordan man forbereder dem\" src=\"\/wp-content\/uploads\/2020\/02\/07d704acf5b9c5a92b2ddf6e05f89f2a.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nJeg tror, det er overfl\u00f8digt at beskrive korrekt tilslutning af kablerne. Hvis du er tr\u00e5dt ind i UPS'en, er du klart bekendt med princippet om seriel forbindelse af batterier. Og for andre: papir - pen eller smartphone med kamera. Efter samlingen m\u00e5ler vi for en sikkerheds skyld sp\u00e6ndingen p\u00e5 samlingen med testeren og sammenligner med det, der burde v\u00e6re, baseret p\u00e5 antallet af batterier.<\/p>\n<h3>\"Jeg gjorde alt, som der st\u00e5r, men det hjalp ikke.\"<\/h3>\n<p>\nMen nu begynder det mest interessante. UPS'en kalibrerer periodisk batteriet (normalt hver 7. eller 14. dag, afh\u00e6ngigt af indstillingen) i sin drift. Den skifter til batteridrift og m\u00e5ler sp\u00e6ndingen straks og efter lidt tid. Resultatet er en korrektion for \"batteriets liv\" ind i dens register. I takt med at batteriet gradvist d\u00f8r, falder v\u00e6rdien i dette register. Ud fra dette beregner UPS'en den resterende driftszeit p\u00e5 batteri. Og p\u00e5 et tidspunkt, n\u00e5r UPS'en indser, at der er problemer, t\u00e6ndes indikatorlampen for at skifte batteriet. Men n\u00e5r vi udskifter det, ved UPS'en det ikke! V\u00e6rdien i registeret for \"batteriets liv\" forbliver den samme. Vi skal justere det.<\/p>\n<p>Der er to veje her. Den f\u00f8rste vej, som er enkel og hurtig \u2013 vi skal lave en komplet kalibrering af UPS'en. For dette skal du belaste den med mere end 35% og starte kalibreringen, for eksempel fra PowerChute-programmet. Dette virker i cirka halvdelen af tilf\u00e6ldene. Hvorfor det ikke altid virker, er et mysterium. Derfor tager vi den lange, men mere p\u00e5lidelige vej.<\/p>\n<p>Vi skal bruge: en computer med COM-port, et originalt kabel (f.eks. 940-0024C), programmet UpsDiag 2.0 (for sikkerheden ved din UPS anbefaler kollegaen, at du bedre bruger apcfix i gratis tilstand. Jeg kan ikke sige noget om dette udover, at jeg kategorisk ikke anbefaler at trykke p\u00e5 noget i UpsDiag undtagen at \u00e6ndre register 0. <i>is\u00e6r knappen til automatisk fejlfinding af batterier<\/i>) og <noindex><a rel=\"nofollow\" href=\"http:\/\/www.apcupsd.com\/manual\/manual.html#configuring-your-eeprom\">kalibreringsv\u00e6rdier tabel<\/a><\/noindex>. Vi er interesserede i v\u00e6rdien af register 0. I tabellen er der angivet v\u00e6rdien for ideelle, sf\u00e6riske batterier i vakuum. Enhver virkelig batteri vil give en lavere v\u00e6rdi efter kalibreringen, men ikke meget lavere.<\/p>\n<p><img decoding=\"async\" alt=\"APC Smart UPS underholdningssystemer, og hvordan man forbereder dem\" src=\"\/wp-content\/uploads\/2020\/02\/93542115e332bece7803efac1c88a284.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nFor eksempel vil jeg tage en rigtig UPS SUA1500RMI2U. P\u00e5 tidspunktet for batteriudskiftningen viste UpsDiag v\u00e6rdien for register 0 \u2013 42. Det vil sige, at batterierne er d\u00f8de. Kalibreringsv\u00e6rdien fra tabellen er A1. <\/p>\n<p>Lad os begynde at justere. F\u00f8rst og fremmest <b>fjern netv\u00e6rkskortet fra UPS'en<\/b>. Presence of the network card will not allow you to adjust the register. Why is a question for the APC engineers. Fortunately, it can be removed on the fly without turning off the UPS. <\/p>\n<p>Tilslut kabel, start UpsDiag, g\u00e5 til fanen \"Kalibrering\" og se status for register 0. Skriv det ned, h\u00f8jreklik p\u00e5 det \u2013 Rediger. H\u00e6v det til v\u00e6rdien fra kalibreringstabellen \u2013 A1. Hvis din UPS ikke er i tabellen, kan du i princippet h\u00e6ve det til FF. Der er ikke noget skr\u00e6mmende ved det, bortset fra en forundret UPS, der viser, at den er klar til at b\u00e6re belastningen indtil dommedag. <\/p>\n<p>Derefter skal vi vente p\u00e5, at batteriet oplades til 100%, belaste UPS'en til 35% eller lidt over og starte kalibreringen. Ved afslutningen af kalibreringen ser vi igen p\u00e5 v\u00e6rdien i register 0 og sammenligner den med den, vi har skrevet ned. I den ovenfor beskrevne SUA1500RMI2U med nye batterier HRL1234W blev v\u00e6rdien 98, hvilket i princippet ikke er meget langt fra kalibreringsv\u00e6rdien A1.<\/p>\n<p>Efter alt dette lader vi den oplades til 100% igen, tr\u00e6kker COM-kablet ud, s\u00e6tter netv\u00e6rkskortet tilbage i og \u00f8nsker UPS'en et langt og lykkeligt liv til gavn for vores serverrack.<\/p>\n<p>For \u00f8vrigt er netv\u00e6rkskort som AP9619 ogs\u00e5 faldet i pris til beskedne v\u00e6rdier p\u00e5 det sekund\u00e6re marked. Men hvordan man forbereder dem (nulstilling af adgangskode, opdatering af firmware, konfiguration) \u2013 det er et emne for en separat artikel.<br \/>\n<br \/>Kilde: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/487802\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric). \u0412\u0435\u043b\u0438\u043a\u043e\u043b\u0435\u043f\u043d\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0438\u0437\u043a\u0430\u044f \u0446\u0435\u043d\u0430 \u043d\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u043c \u0440\u044b\u043d\u043a\u0435, \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u044e\u0442 \u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u0441\u0438\u0441\u0430\u0434\u043c\u0438\u043d\u044b, \u043e\u0441\u043e\u0431\u043e \u043d\u0435 \u0437\u0430\u0434\u0443\u043c\u044b\u0432\u0430\u044f\u0441\u044c, \u0443\u0442\u044b\u043a\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u043e\u0439\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u043c\u0438 \u0418\u0411\u041f \u0438 \u043f\u044b\u0442\u0430\u044e\u0442\u0441\u044f \u0432\u044b\u0442\u044f\u043d\u0443\u0442\u044c \u0441 \u0436\u0435\u043b\u0435\u0437\u043e\u043a 10-15 \u043b\u0435\u0442\u043d\u0435\u0439 \u0434\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0443\u043c \u043f\u0440\u043e\u0444\u0438\u0442\u0430 \u0431\u0430\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u043e\u0439 \u0430\u043a\u043a\u0443\u043c\u0443\u043b\u044f\u0442\u043e\u0440\u043e\u0432. \u041a \u0441\u043e\u0436\u0430\u043b\u0435\u043d\u0438\u044e \u043d\u0435 \u0432\u0441\u0435\u0433\u0434\u0430 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-56401","post","type-post","status-publish","format-standard","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.3 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/da\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"da_DK\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/da\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-02-11T21:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-02-18T11:04:41+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47APC Smart UPS og hvordan man forbereder dem | ProHoster","description":"Blandt alle typer UPS'er betragtes APC Smart UPS (nu \u2013 Schneider Electric) som de mest udbredte i entry-level serverrum.","canonical_url":"https:\/\/prohoster.info\/da\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"da_DK","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster","og:description":"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).","og:url":"https:\/\/prohoster.info\/da\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-02-11T21:00:00+00:00","article:modified_time":"2020-02-18T11:04:41+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"56401","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 19:25:39","updated":"2022-09-29 13:07:34","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/posts\/56401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/comments?post=56401"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/posts\/56401\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/media?parent=56401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/categories?post=56401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/da\/wp-json\/wp\/v2\/tags?post=56401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}