{"id":30008,"date":"2019-10-31T21:33:10","date_gmt":"2019-10-31T18:33:10","guid":{"rendered":"https:\/\/prohoster.info\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat\/"},"modified":"2019-10-31T21:33:10","modified_gmt":"2019-10-31T18:33:10","slug":"vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat","status":"publish","type":"post","link":"https:\/\/prohoster.info\/de\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat","title":{"rendered":"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/7832ecf74ccec07328f8e99b01ccb81f.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/dataline\/blog\/432980\/\">Teil eins<\/a><\/noindex><br \/>\nNach einer kurzen Pause kehren wir zu NSX zur\u00fcck. Heute zeige ich Ihnen, wie Sie NAT und Firewall konfigurieren.<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nIm Tab <b>Verwaltung<\/b> gehen Sie zu Ihrem virtuellen Rechenzentrum \u2013 <b>Cloud-Ressourcen \u2013 Virtuelle Rechenzentren<\/b>. <\/p>\n<p>W\u00e4hlen Sie den Tab <b>Edge-Gateways<\/b> und klicken Sie mit der rechten Maustaste auf das gew\u00fcnschte NSX Edge. W\u00e4hlen Sie im angezeigten Men\u00fc die Option <b>Edge Gateway-Dienste<\/b>. Das NSX Edge-Dashboard \u00f6ffnet sich in einem neuen Tab.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/53dd4a66d2ad186361068541c5c9ccbd.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h3>Konfiguration der Firewall-Regeln<\/h3>\n<p>\nStandardm\u00e4\u00dfig ist unter <b>Standardregel f\u00fcr eingehenden Verkehr<\/b> die Option Ablehnen ausgew\u00e4hlt, d. h. die Firewall blockiert gesamten Verkehr.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/7afeb9fd3395deb50eb821c449e8097d.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n <br \/>\nUm eine neue Regel hinzuzuf\u00fcgen, klicken Sie auf +. Es wird ein neuer Eintrag mit dem Namen <b>Neue Regel<\/b>. Bearbeiten Sie die Felder nach Ihren Anforderungen.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/81ff3b24755037f2ff59929302dab506.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIm Feld <b>Name<\/b> Geben Sie den Namen der Regel ein, zum Beispiel Internet.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/20ca48498e5828adc55f9e320b174c86.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIm Feld <b>Source<\/b> geben Sie die erforderlichen Quelladressen ein. Mit der Schaltfl\u00e4che IP k\u00f6nnen Sie eine einzelne IP-Adresse, einen IP-Adressbereich oder CIDR angeben.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/ff41fd0ba2fd3efb9cce4de006daacc8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/fbf8c474a153b1c2ab04bb0a768bddf4.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n <br \/>\nMit der Schaltfl\u00e4che + k\u00f6nnen Sie weitere Objekte angeben:<\/p>\n<ul>\n<li>Gateway-Schnittstellen. Alle internen Netzwerke (Internal), alle externen Netzwerke (External) oder Any.\n<\/li>\n<li>Virtuelle Maschinen. Regeln werden an eine bestimmte virtuelle Maschine gebunden.\n<\/li>\n<li>OrgVdcNetzwerke. Netzwerke auf Organisationsebene.\n<\/li>\n<li>IP-Sets. Vom Benutzer vordefinierte IP-Adressen-Gruppe (erstellt in Grouping object).\n<\/li>\n<\/ul>\n<p>\n<img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/a1857b7397da44595c9ad5a9333b7656.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/30150e004add4a2d8c3acf08aff69b24.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIm Feld <b>Ziel<\/b> Geben Sie die Empf\u00e4ngeradresse an. Hier stehen die gleichen Optionen wie im Feld Quelle zur Verf\u00fcgung.<br \/>\nIm Feld <b>Service<\/b> Sie k\u00f6nnen den Zielport (Destination Port), das ben\u00f6tigte Protokoll (Protocol) und den Quellport (Source Port) entweder ausw\u00e4hlen oder manuell angeben. Klicken Sie auf Beibehalten.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/32bec78ca59ec8abbc944f0544e52365.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/e007ccf49b922f14445919c5ff949451.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIm Feld <b>Aktionen<\/b> W\u00e4hlen Sie die erforderliche Aktion aus: Erlauben Sie den Verkehr, der dieser Regel entspricht, oder verbieten Sie ihn.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/ed6453a0e250a4cf817b67855d3094c0.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nWenden Sie die eingegebene Konfiguration an, indem Sie den Punkt ausw\u00e4hlen <b>\u00c4nderungen speichern<\/b>.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/942a0a31c1329237af9bc16f76eab6fb.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<b>Regelbeispiele<\/b><\/p>\n<p><i>Regel 1 f\u00fcr Firewall (Internet)<\/i> erlaubt den Zugriff auf das Internet mit beliebigen Protokollen f\u00fcr den Server mit der IP 192.168.1.10. <\/p>\n<p><i>Regel 2 f\u00fcr Firewall (Web-Server)<\/i> erlaubt den Zugang aus dem Internet \u00fcber (TCP-Protokoll, Port 80) \u00fcber Ihre externe Adresse. In diesem Fall \u2013 185.148.83.16:80.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/c0ed5a3d5b4f0972fc4326e4cd3a102b.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h1>NAT-Konfiguration<\/h1>\n<p>\n<b>NAT (Network Address Translation)<\/b> \u2013 die Umwandlung von privaten (grauen) IP-Adressen in \u00f6ffentliche (wei\u00dfe) und umgekehrt. So erh\u00e4lt die virtuelle Maschine Zugriff auf das Internet. Zur Einrichtung dieses Mechanismus m\u00fcssen SNAT- und DNAT-Regeln konfiguriert werden.<br \/>\nWichtig! NAT funktioniert nur, wenn die Firewall aktiviert ist und die entsprechenden erlaubenden Regeln konfiguriert sind.<\/p>\n<p><b>Erstellung einer SNAT-Regel.<\/b> SNAT (Source Network Address Translation) \u2013 ein Mechanismus, dessen Hauptzweck darin besteht, die Quelladresse beim Weiterleiten eines Pakets zu ersetzen. <\/p>\n<p>Zun\u00e4chst m\u00fcssen wir die verf\u00fcgbare externe IP-Adresse oder den IP-Adressbereich herausfinden. Gehen Sie dazu in den Bereich <b>Verwaltung<\/b> und doppelklicken Sie auf das virtuelle Rechenzentrum. Im sich \u00f6ffnenden Einstellungsmen\u00fc wechseln Sie zur Registerkarte <b>Edge Gateway<\/b>s. W\u00e4hlen Sie den gew\u00fcnschten NSX Edge aus und klicken Sie mit der rechten Maustaste darauf. W\u00e4hlen Sie die Option <b>Eigenschaften<\/b>.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/fe916f4d7a78f559e4ba7982e1be6855.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIm sich \u00f6ffnenden Fenster in der Registerkarte <b>Sub-Allocate IP Pools<\/b> k\u00f6nnen Sie die externe IP-Adresse oder den IP-Adressbereich einsehen. Notieren Sie ihn oder merken Sie ihn sich.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/e52dbc90f57d0b273a9e547c9ac1f854.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nKlicken Sie dann mit der rechten Maustaste auf den NSX Edge. W\u00e4hlen Sie im sich \u00f6ffnenden Men\u00fc die Option <b>Edge Gateway-Dienste<\/b>. Und wir sind wieder im <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/de\/control-panel\/\"   title=\"Kontrollpanels\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"537\">Kontrollpanels<\/a> NSX Edge.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/50fc0194a0a3ca03e2238f8a31017921.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIm sich \u00f6ffnenden Fenster \u00f6ffnen wir die Registerkarte NAT und klicken auf Add SNAT. <\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/371287db97e6a6dac1f688d2b78af20a.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIm neuen Fenster geben wir an: <\/p>\n<ul>\n<li>Im Feld 'Applied on' \u2013 externe Netzwerk (nicht das Netzwerk der Organisation!); <\/li>\n<li>Original Source IP\/Rang \u2013 interner Adressbereich, z. B. 192.168.1.0\/24;<\/li>\n<li>Translated Source IP\/Rang \u2013 externe Adresse, \u00fcber die der Internetzugang erfolgt und die Sie im Tab Sub-Allocate IP Pools gesehen haben.<\/li>\n<\/ul>\n<p>\nKlicken Sie auf Keep. <\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/aed08ee1621feeed3979889e9d962237.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<b>Erstellen einer DNAT-Regel.<\/b> DNAT ist ein Mechanismus, der die Zieladresse und den Zielport eines Pakets \u00e4ndert. Er wird verwendet, um eingehende Pakete von einer externen Adresse\/Port an eine private IP-Adresse\/Port innerhalb eines privaten Netzwerks umzuleiten. <\/p>\n<p>W\u00e4hlen Sie den Tab NAT und klicken Sie auf Add DNAT.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/fb66ecd7a49b0d280ded36ba0e214c8d.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nGeben Sie im sich \u00f6ffnenden Fenster an:<\/p>\n<p> \u2014 im Feld Applied on \u2013 das externe Netzwerk (nicht das Netzwerk auf Organisationsebene!);<br \/>\n \u2014 Original IP\/Range \u2013 die externe Adresse (Adresse aus dem Tab Sub-Allocate IP Pools);<br \/>\n \u2014 Protocol \u2013 das Protokoll; <br \/>\n \u2014 Original Port \u2013 der Port f\u00fcr die externe Adresse; <br \/>\n \u2014 Translated IP\/Range \u2013 die interne IP-Adresse, z.B. 192.168.1.10<br \/>\n \u2014 Translated Port \u2013 der Port f\u00fcr die interne Adresse, auf die der Port der externen Adresse \u00fcbersetzt wird. <\/p>\n<p>Klicken Sie auf Keep.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/da428038cf8f6821dc092adaa33d891a.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nWenden Sie die eingegebene Konfiguration an, indem Sie den Punkt ausw\u00e4hlen <b>\u00c4nderungen speichern<\/b>.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/e88de8bd19d4caa2a03a84b8294fa57e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nFertig.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration\" src=\"\/wp-content\/uploads\/2019\/03\/050d5c167d66c5d3e5ee83378bf486f4.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nAls n\u00e4chstes folgt die Anleitung zu DHCP, einschlie\u00dflich der Einrichtung von DHCP Bindings und Relay.<br \/>\n<br \/>Quelle: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/dataline\/blog\/441026\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0427\u0430\u0441\u0442\u044c \u043f\u0435\u0440\u0432\u0430\u044f \u041f\u043e\u0441\u043b\u0435 \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u0430 \u0432\u043e\u0437\u0432\u0440\u0430\u0449\u0430\u0435\u043c\u0441\u044f \u043a NSX. \u0421\u0435\u0433\u043e\u0434\u043d\u044f \u043f\u043e\u043a\u0430\u0436\u0443, \u043a\u0430\u043a \u043d\u0430\u0441\u0442\u0440\u043e\u0438\u0442\u044c NAT \u0438 Firewall. \u0412\u043e \u0432\u043a\u043b\u0430\u0434\u043a\u0435 Administration \u043f\u0435\u0440\u0435\u0439\u0434\u0438\u0442\u0435 \u0432 \u0432\u0430\u0448 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u0434\u0430\u0442\u0430-\u0446\u0435\u043d\u0442\u0440 \u2013 Cloud Resources \u2013 Virtual Datacenters. \u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u0432\u043a\u043b\u0430\u0434\u043a\u0443 Edge Gateways \u0438 \u043a\u043b\u0438\u043a\u043d\u0438\u0442\u0435 \u043d\u0430 \u043d\u0443\u0436\u043d\u044b\u0439 NSX Edge \u043f\u0440\u0430\u0432\u043e\u0439 \u043a\u043d\u043e\u043f\u043a\u043e\u0439 \u043c\u044b\u0448\u0438. \u0412 \u043f\u043e\u044f\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u043c\u0435\u043d\u044e \u0432\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043e\u043f\u0446\u0438\u044e Edge Gateway Services. \u041f\u0430\u043d\u0435\u043b\u044c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f NSX Edge \u043e\u0442\u043a\u0440\u043e\u0435\u0442\u0441\u044f [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[10],"tags":[],"class_list":["post-30008","post","type-post","status-publish","format-standard","hentry","category-blog"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0427\u0430\u0441\u0442\u044c \u043f\u0435\u0440\u0432\u0430\u044f \u041f\u043e\u0441\u043b\u0435 \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u0430 \u0432\u043e\u0437\u0432\u0440\u0430\u0449\u0430\u0435\u043c\u0441\u044f \u043a NSX. \u0421\u0435\u0433\u043e\u0434\u043d\u044f \u043f\u043e\u043a\u0430\u0436\u0443, \u043a\u0430\u043a \u043d\u0430\u0441\u0442\u0440\u043e\u0438\u0442\u044c NAT \u0438 Firewall. \u0412\u043e \u0432\u043a\u043b\u0430\u0434\u043a\u0435 Administration \u043f\u0435\u0440\u0435\u0439\u0434\u0438\u0442\u0435 \u0432 \u0432\u0430\u0448 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u0434\u0430\u0442\u0430-\u0446\u0435\u043d\u0442\u0440 \u2013 Cloud Resources \u2013 Virtual Datacenters. \u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u0432\u043a\u043b\u0430\u0434\u043a\u0443 Edge Gateways \u0438 \u043a\u043b\u0438\u043a\u043d\u0438\u0442\u0435 \u043d\u0430 \u043d\u0443\u0436\u043d\u044b\u0439 NSX Edge \u043f\u0440\u0430\u0432\u043e\u0439 \u043a\u043d\u043e\u043f\u043a\u043e\u0439 \u043c\u044b\u0448\u0438. \u0412 \u043f\u043e\u044f\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u043c\u0435\u043d\u044e \u0432\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043e\u043f\u0446\u0438\u044e Edge Gateway Services. \u041f\u0430\u043d\u0435\u043b\u044c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f NSX Edge \u043e\u0442\u043a\u0440\u043e\u0435\u0442\u0441\u044f\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/de\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47VMware NSX \u0434\u043b\u044f \u0441\u0430\u043c\u044b\u0445 \u043c\u0430\u043b\u0435\u043d\u044c\u043a\u0438\u0445. \u0427\u0430\u0441\u0442\u044c 2. \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 Firewall \u0438 NAT | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0427\u0430\u0441\u0442\u044c \u043f\u0435\u0440\u0432\u0430\u044f \u041f\u043e\u0441\u043b\u0435 \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u0430 \u0432\u043e\u0437\u0432\u0440\u0430\u0449\u0430\u0435\u043c\u0441\u044f \u043a NSX. \u0421\u0435\u0433\u043e\u0434\u043d\u044f \u043f\u043e\u043a\u0430\u0436\u0443, \u043a\u0430\u043a \u043d\u0430\u0441\u0442\u0440\u043e\u0438\u0442\u044c NAT \u0438 Firewall. \u0412\u043e \u0432\u043a\u043b\u0430\u0434\u043a\u0435 Administration \u043f\u0435\u0440\u0435\u0439\u0434\u0438\u0442\u0435 \u0432 \u0432\u0430\u0448 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u0434\u0430\u0442\u0430-\u0446\u0435\u043d\u0442\u0440 \u2013 Cloud Resources \u2013 Virtual Datacenters. \u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u0432\u043a\u043b\u0430\u0434\u043a\u0443 Edge Gateways \u0438 \u043a\u043b\u0438\u043a\u043d\u0438\u0442\u0435 \u043d\u0430 \u043d\u0443\u0436\u043d\u044b\u0439 NSX Edge \u043f\u0440\u0430\u0432\u043e\u0439 \u043a\u043d\u043e\u043f\u043a\u043e\u0439 \u043c\u044b\u0448\u0438. \u0412 \u043f\u043e\u044f\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u043c\u0435\u043d\u044e \u0432\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043e\u043f\u0446\u0438\u044e Edge Gateway Services. \u041f\u0430\u043d\u0435\u043b\u044c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f NSX Edge \u043e\u0442\u043a\u0440\u043e\u0435\u0442\u0441\u044f\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/de\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T18:33:10+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T18:33:10+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47VMware NSX f\u00fcr die Kleinsten. Teil 2. Firewall- und NAT-Konfiguration | ProHoster","description":"Teil eins Nach einer kurzen Pause kehren wir zu NSX zur\u00fcck. Heute zeige ich, wie man NAT und Firewall einrichtet. Gehen Sie im Tab Administration zu Ihrem virtuellen Rechenzentrum \u2013 Cloud-Ressourcen \u2013 Virtuelle Rechenzentren. W\u00e4hlen Sie den Tab Edge Gateways und klicken Sie mit der rechten Maustaste auf den gew\u00fcnschten NSX Edge. W\u00e4hlen Sie im sich \u00f6ffnenden Men\u00fc die Option Edge Gateway Services. Das NSX Edge-Dashboard wird ge\u00f6ffnet.","canonical_url":"https:\/\/prohoster.info\/de\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"de_DE","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47VMware NSX \u0434\u043b\u044f \u0441\u0430\u043c\u044b\u0445 \u043c\u0430\u043b\u0435\u043d\u044c\u043a\u0438\u0445. \u0427\u0430\u0441\u0442\u044c 2. \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 Firewall \u0438 NAT | ProHoster","og:description":"\u0427\u0430\u0441\u0442\u044c \u043f\u0435\u0440\u0432\u0430\u044f \u041f\u043e\u0441\u043b\u0435 \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u0430 \u0432\u043e\u0437\u0432\u0440\u0430\u0449\u0430\u0435\u043c\u0441\u044f \u043a NSX. \u0421\u0435\u0433\u043e\u0434\u043d\u044f \u043f\u043e\u043a\u0430\u0436\u0443, \u043a\u0430\u043a \u043d\u0430\u0441\u0442\u0440\u043e\u0438\u0442\u044c NAT \u0438 Firewall. \u0412\u043e \u0432\u043a\u043b\u0430\u0434\u043a\u0435 Administration \u043f\u0435\u0440\u0435\u0439\u0434\u0438\u0442\u0435 \u0432 \u0432\u0430\u0448 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u0434\u0430\u0442\u0430-\u0446\u0435\u043d\u0442\u0440 \u2013 Cloud Resources \u2013 Virtual Datacenters. \u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u0432\u043a\u043b\u0430\u0434\u043a\u0443 Edge Gateways \u0438 \u043a\u043b\u0438\u043a\u043d\u0438\u0442\u0435 \u043d\u0430 \u043d\u0443\u0436\u043d\u044b\u0439 NSX Edge \u043f\u0440\u0430\u0432\u043e\u0439 \u043a\u043d\u043e\u043f\u043a\u043e\u0439 \u043c\u044b\u0448\u0438. \u0412 \u043f\u043e\u044f\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u043c\u0435\u043d\u044e \u0432\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043e\u043f\u0446\u0438\u044e Edge Gateway Services. \u041f\u0430\u043d\u0435\u043b\u044c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f NSX Edge \u043e\u0442\u043a\u0440\u043e\u0435\u0442\u0441\u044f","og:url":"https:\/\/prohoster.info\/de\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T18:33:10+00:00","article:modified_time":"2019-10-31T18:33:10+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"30008","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"Article","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-02-08 19:52:40","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 03:44:39","updated":"2026-02-08 19:52:40"},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/posts\/30008","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/comments?post=30008"}],"version-history":[{"count":1,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/posts\/30008\/revisions"}],"predecessor-version":[{"id":157727,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/posts\/30008\/revisions\/157727"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/media?parent=30008"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/categories?post=30008"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/tags?post=30008"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}