{"id":38294,"date":"2019-10-31T22:22:48","date_gmt":"2019-10-31T19:22:48","guid":{"rendered":"https:\/\/prohoster.info\/blog\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\/"},"modified":"2019-10-31T22:22:48","modified_gmt":"2019-10-31T19:22:48","slug":"anboksing-stoechnogo-servera-cisco-ucs-c240-m5","status":"publish","type":"post","link":"https:\/\/prohoster.info\/de\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","title":{"rendered":"Unboxing des Rack-Servers Cisco UCS C240 M5","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Heute haben wir einen neuen Rack-Server, den Cisco UCS C240 der f\u00fcnften Generation, auf dem Tisch. <\/p>\n<p>Was macht diesen Cisco-Server, den wir hier im f\u00fcnften Generation sehen, interessant f\u00fcr ein Unboxing? <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing des Rack-Servers Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/419d39ba895739a71b337f03445a9c32.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nErstens unterst\u00fctzen Cisco-Server jetzt die neuesten Generationen von Intel Scalable Prozessoren der zweiten Generation. Zweitens k\u00f6nnen jetzt Optane-Speichermodule installiert werden, um zahlreiche NVMe-Speicher zu nutzen. <br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nEs stellen sich berechtigte Fragen: K\u00f6nnen Server anderer Anbieter das nicht auch? Was macht das so besonders, schlie\u00dflich ist es nur ein x86-Server? Lassen Sie uns alles der Reihe nach durchgehen. <\/p>\n<p>Neben den Aufgaben eines eigenst\u00e4ndigen Servers kann der Cisco C240 M5 Teil der Architektur von Cisco UCS werden. Hier sprechen wir \u00fcber die Anbindung an FI und die vollst\u00e4ndige Verwaltung der Server durch UCS Manager, einschlie\u00dflich Auto Deploy. <\/p>\n<p>Also, wir haben hier einen \u201estahlharten\u201c Cisco-Server, die f\u00fcnfte Generation, die seit \u00fcber 10 Jahren auf dem Markt ist. <br \/>\nJetzt werden wir uns auf die Grundlagen besinnen, erinnern, aus welchen Komponenten der Server besteht, und was den Cisco C240 M5 nicht nur modern, sondern wirklich fortschrittlich macht. <\/p>\n<p>Lassen Sie uns einen Blick darauf werfen, was im Lieferumfang enthalten ist. <\/p>\n<p><b>Inhalt der Verpackung<\/b>: Server, KVM-Dongle, Dokumente, Diskette, 2 Netzkabel, Montagesatz. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing des Rack-Servers Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/4e6b39ebc4a78f8b37b29ea2d76da14e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nWir entfernen die Abdeckung. Dr\u00fccken, schieben und fertig. Keine Schraubenzieher und keine verlorenen Schrauben. <br \/>\nSofort fallen die gr\u00fcnen Etiketten ins Auge. Alle Elemente, die Hot-Swap unterst\u00fctzen, verf\u00fcgen dar\u00fcber. Beispielsweise k\u00f6nnen die L\u00fcfter problemlos ohne Abschaltung des gesamten Servers ausgetauscht werden. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing des Rack-Servers Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/cb2fcaf627f96dd947421f65e80c2638.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nWir sehen auch massive K\u00fchlk\u00f6rper, unter denen sich die neuen Intel Scal 2 Gen Prozessoren verstecken. Es ist zu beachten, dass dies bis zu 56 Kerne auf einem 2U-Server ohne K\u00fchlungsprobleme unterst\u00fctzt. Zudem wird mehr Speicher unterst\u00fctzt, bis zu 1TB pro Prozessor. Die unterst\u00fctzte Speichergeschwindigkeit ist ebenfalls auf 2933 MHz gestiegen. <\/p>\n<p>Neben der CPU sehen wir 24 Steckpl\u00e4tze f\u00fcr den Arbeitsspeicher \u2013 man kann Module mit bis zu 128 GB oder Intel Optane-Speicher mit bis zu 512 GB pro Steckplatz verwenden.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing des Rack-Servers Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/147f87e31e346dbb0f360c92dccde512.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIntel Optane er\u00f6ffnet uns rasante Verarbeitungsgeschwindigkeiten. Beispielsweise kann es als super schnelles lokales SSD-Laufwerk genutzt werden.<\/p>\n<p>Immer mehr Anfragen von Kunden beginnen mit den Worten: \"Ich m\u00f6chte mehr Festplatten, mehr NVMe-Speicher in einem System\". <\/p>\n<p>Auf der Vorderseite sehen wir 8 2,5-Zoll-Steckpl\u00e4tze f\u00fcr Speichermedien. Au\u00dferdem ist eine Version der Plattform mit 24 Steckpl\u00e4tzen an der Front verf\u00fcgbar.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing des Rack-Servers Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/ddeca4947e941f1dadfe2a691b8729d8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nJe nach Modifikation k\u00f6nnen in die ersten Slots bis zu 8 NMVe-Laufwerke im U.2-Formfaktor installiert werden. <\/p>\n<p>Die C240-Plattform ist insgesamt bei Kunden, die sich mit Big Data besch\u00e4ftigen, sehr beliebt. Ihre Hauptanfrage ist die M\u00f6glichkeit, Speichermedien f\u00fcr lokale Installationen zu haben, und vorzugsweise hot-pluggable.<\/p>\n<p>Die Antwort auf diese Anfrage war die Entscheidung von Cisco, in den C240 M5 zwei Slots f\u00fcr Laufwerke f\u00fcr Hot-Swap-Unterst\u00fctzung auf der R\u00fcckseite des Servers hinzuzuf\u00fcgen.<\/p>\n<p>Sie befinden sich rechts von den Erweiterungsslots zu den Netzteilen. Die Speichermedien k\u00f6nnen beliebig sein: SAS, SATA, SSD, NVMe.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing des Rack-Servers Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/33ef5ba06667b6e130ce724bd27cf857.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nNebenan sehen wir die 1600W-Netzteile. Diese sind ebenfalls Hot-Pluggable und mit gr\u00fcnen Etiketten versehen.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing des Rack-Servers Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/46ab4548bc3d84d497f772f7c8eaa633.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nF\u00fcr die Arbeit mit dem Speicher-Subsystem kann ein RAID-Controller von LSI mit 2 GB Cache in den dedizierten Slot installiert werden, oder eine HBA-Karte f\u00fcr die direkte Durchleitung.<\/p>\n<p>Ein solcher Ansatz wird beispielsweise beim Aufbau der hyperkonvergenten L\u00f6sung Cisco HyperFlex verwendet.<\/p>\n<p>Es gibt einen anderen Typ von Kunden, die \u00fcberhaupt keine Laufwerke ben\u00f6tigen. Sie m\u00f6chten keinen vollst\u00e4ndigen RAID-Controller f\u00fcr den Hypervisor installieren, aber sie m\u00f6gen das 2U-Geh\u00e4use wegen der Benutzerfreundlichkeit.<br \/>\nF\u00fcr sie hat Cisco ebenfalls eine L\u00f6sung.<\/p>\n<p>Ich pr\u00e4sentiere das FlexFlash-Modul:<br \/>\nZwei SD-Karten mit einer Kapazit\u00e4t von bis zu 128 GB, mit Unterst\u00fctzung f\u00fcr Mirroring, zur Installation des Hypervisors, beispielsweise VMware ESXi. Genau diese Variante verwenden wir bei ITGLOBAL.COM, um unsere eigenen Standorte weltweit aufzubauen. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing des Rack-Servers Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/d265c93e1e60428c69132b3cddb3a790.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nF\u00fcr die Kunden, die mehr Platz f\u00fcr die Betriebssysteminstallation ben\u00f6tigen, gibt es die Option eines Moduls mit zwei SATA-SSDs im M.2-Format, jede mit 240 oder 960 GB. Standardm\u00e4\u00dfig ist dies ein Software-RAID. <\/p>\n<p>F\u00fcr 240 GB Laufwerke gibt es die Option, den Cisco Boot-optimierten M.2 RAID-Controller zu verwenden \u2013 einen separaten Hardware-RAID-Controller f\u00fcr diese beiden SSD-Laufwerke.<\/p>\n<p>All dies wird von allen Betriebssystemen unterst\u00fctzt: sowohl VMware als auch Windows und verschiedenen Linux-OS.<br \/>\nDie Anzahl der PCI-Slots betr\u00e4gt 6, was f\u00fcr eine 2U-Plattform charakteristisch ist. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing des Rack-Servers Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/67f57214e9f99cbad0add05865ed83f8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIm Inneren ist gen\u00fcgend Platz. In die Server k\u00f6nnen problemlos zwei vollst\u00e4ndige Grafikbeschleuniger von NVidia, zum Beispiel TESLA M10 f\u00fcr Implementierungsprojekte, installiert werden. <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/de\/vps\/abuzoustojchivye-vps\/\"   title=\"virtuellen Arbeitspl\u00e4tzen\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"1009\">virtuellen Arbeitspl\u00e4tzen<\/a> Oder die neueste Version V100 mit 32GB f\u00fcr Aufgaben der k\u00fcnstlichen Intelligenz. Diese setzen wir im n\u00e4chsten Unboxing ein.<\/p>\n<p>Die Ports sind wie folgt: <\/p>\n<ul>\n<li>Konsole-Port;<\/li>\n<li>Gigabit-Dedikationsport f\u00fcr die Verwaltung;<\/li>\n<li>Zwei USB 3.0 Ports;<\/li>\n<li>Integrierte 2-Port-Netzwerkkarte Intel x550 10Gb BASE-T;<\/li>\n<li>Optionale mLOM-Karte, Cisco Vic 1387 Dual-Port-Adapter mit 40 Gb.<\/li>\n<\/ul>\n<p>\nIn den mLOM-Slot k\u00f6nnen nur Cisco VIC-Karten eingesetzt werden, die sowohl f\u00fcr die \u00dcbertragung von LAN- als auch von SAN-Verkehr effizient sind. Bei Verwendung des Servers im Cisco UCS-Fabric erm\u00f6glicht dieser Ansatz eine einheitliche Verbindung zu LAN- und SAN-Netzen, ohne dass ein separater FC-Adapter erforderlich ist. <\/p>\n<p>Lassen Sie uns den Nvidia V100 Grafikbeschleuniger installieren. Wir entfernen den zweiten Riser, nehmen die Blende ab, stecken die Karte in den PCI-Slot, schlie\u00dfen das Plastik und dann die Blende. Wir verbinden die zus\u00e4tzliche Stromversorgung. Zuerst an die Karte, dann an den Riser. Wir setzen den Riser wieder an seinen Platz. Insgesamt verl\u00e4uft alles ohne den Einsatz von Schraubenziehern und H\u00e4mmern. Schnell und pr\u00e4zise.<\/p>\n<p>In einem der n\u00e4chsten Materialien werden wir die erste Installation zeigen. <\/p>\n<p>Wir sind auch bereit, alle Fragen zu beantworten <noindex><a rel=\"nofollow\" href=\"https:\/\/itglobal.com\/ru-ru\/solutions\/tech-partners\/cisco\/servers-unified-computing-system-ucs\/\">hier<\/a><\/noindex> oder in den Kommentaren.<br \/>\n<br \/>Quelle: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/itglobalcom\/blog\/467981\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435? \u0412\u043e-\u043f\u0435\u0440\u0432\u044b\u0445, \u0441\u0435\u0440\u0432\u0435\u0440\u044b Cisco \u0442\u0435\u043f\u0435\u0440\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u0432 Intel Scalable \u0432\u0442\u043e\u0440\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0412\u043e-\u0432\u0442\u043e\u0440\u044b\u0445, \u0442\u0435\u043f\u0435\u0440\u044c \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043c\u043e\u0434\u0443\u043b\u0438 Optane Memory \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u0430 NVMe-\u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":28746,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-38294","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/de\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/de\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Unboxing des Rack-Servers Cisco UCS C240 M5 | ProHoster","description":"Heute haben wir einen neuen Rack-Server Cisco UCS C240 der f\u00fcnften Generation auf dem Tisch. Was macht diesen Cisco-Server gerade f\u00fcr das Unboxing besonders, angesichts dessen, dass wir bereits die f\u00fcnfte Generation vor uns haben?","canonical_url":"https:\/\/prohoster.info\/de\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"de_DE","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster","og:description":"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?","og:url":"https:\/\/prohoster.info\/de\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:22:48+00:00","article:modified_time":"2019-10-31T19:22:48+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"38294","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-02-09 13:06:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 01:12:21","updated":"2026-02-09 13:06:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/posts\/38294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/comments?post=38294"}],"version-history":[{"count":1,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/posts\/38294\/revisions"}],"predecessor-version":[{"id":158206,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/posts\/38294\/revisions\/158206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/media\/28746"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/media?parent=38294"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/categories?post=38294"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/de\/wp-json\/wp\/v2\/tags?post=38294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}