{"id":34884,"date":"2019-10-31T22:01:01","date_gmt":"2019-10-31T19:01:01","guid":{"rendered":"https:\/\/prohoster.info\/blog\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\/"},"modified":"2019-10-31T22:01:01","modified_gmt":"2019-10-31T19:01:01","slug":"upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","status":"publish","type":"post","link":"https:\/\/prohoster.info\/es\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","title":{"rendered":"Actualizaci\u00f3n del subsistema de disco de un servidor antiguo con bus PCIe 1.0 \u2014 2.0","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Actualizaci\u00f3n del subsistema de disco de un servidor antiguo con bus PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/68025340a72b1acac62371764f328712.jpg\" style=\"display:block;margin: 0 auto;\" \/><b class=\"spoiler_title\">Por qu\u00e9 se eligi\u00f3 el tema de este art\u00edculo sobre la actualizaci\u00f3n del subsistema de discos<\/b>Est\u00e1 claro que, en primer lugar, es necesario, por lo general:<\/p>\n<ol>\n<li>Aumentar la memoria RAM. Esta es una medida tan obvia que ni siquiera consider\u00e9 necesario escribir al respecto en el art\u00edculo principal<\/li>\n<li>Instalar un procesador adicional o reemplazar ambos procesadores por las versiones m\u00e1s potentes que son compatibles con los z\u00f3calos del servidor.<\/li>\n<\/ol>\n<p>\nPara servidores antiguos, tanto la memoria como los procesadores suelen encontrarse a precios muy bajos.<\/p>\n<p>En determinado momento, cualquier propietario de su propio servidor se enfrenta a la pregunta: \u00bfactualizaci\u00f3n o nuevo servidor?<\/p>\n<p>Dado que el precio de un nuevo servidor puede alcanzar millones de rublos, muchos optan por la ruta de la actualizaci\u00f3n.<\/p>\n<p>Para una actualizaci\u00f3n exitosa, es muy importante utilizar compromisos, de modo que, por un costo insignificante (en relaci\u00f3n con el precio de un nuevo servidor), obtengamos una mejora significativa en el rendimiento.<\/p>\n<p>En el art\u00edculo se presenta una lista de SSD PCI-E 2.0 x8 para servidores que han bajado de precio, se indican controladores RAID con soporte para almacenamiento en cach\u00e9 SSD y se ha probado SATA III SSD en la interfaz SATA II.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nLa forma m\u00e1s obvia de actualizar el subsistema de discos es pasar de HDD a SSD. Esto es cierto tanto para port\u00e1tiles como para servidores. En servidores, quiz\u00e1s la \u00fanica diferencia sea que los SSD se pueden agrupar f\u00e1cilmente en RAID.<\/p>\n<p>Sin embargo, existen algunos matices relacionados con el hecho de que puede que no haya puertos SATA III en un servidor antiguo y, en tal caso, ser\u00e1 necesario reemplazar o instalar un controlador adecuado.<\/p>\n<p>Claro que tambi\u00e9n hay m\u00e9todos intermedios.<\/p>\n<h2>Almacenamiento en cach\u00e9 en SSD.<\/h2>\n<p>\nEn general, este m\u00e9todo es bastante adecuado para bases de datos, 1C y cualquier acceso aleatorio. La velocidad realmente se acelera. Sin embargo, para archivos enormes o videovigilancia, este m\u00e9todo es in\u00fatil.<\/p>\n<h3>Controladores RAID LSI (IBM, DELL, CISCO, Fujitsu)<\/h3>\n<p>\nA partir de la serie 92xx, LSI tiene la tecnolog\u00eda CacheCade 2.0, que permite utilizar casi cualquier SSD SATA como cach\u00e9 para el RAID. Tanto para lectura como para escritura. E incluso crear un espejo a partir de SSD que est\u00e1n en cach\u00e9.<\/p>\n<p>Con los controladores de marca, es m\u00e1s complicado. En especial en lo que respecta a IBM. Tendr\u00e1s que comprar llaves y SSD para CacheCade a precios exorbitantes en IBM, por lo que es m\u00e1s f\u00e1cil cambiar el controlador a LSI y comprar una llave de hardware m\u00e1s asequible. Las llaves de software son significativamente m\u00e1s caras que las de hardware.<\/p>\n<h3>Controladores RAID Adaptec<\/h3>\n<p>\nLos controladores Adaptec cuentan con la tecnolog\u00eda MaxCache, que tambi\u00e9n permite utilizar SSD como cach\u00e9. Nos interesan las versiones de controladores que terminan con la letra Q.<\/p>\n<p>Los controladores Q pueden utilizar casi cualquier SSD, y no solo los SSD proporcionados por Adaptec.<\/p>\n<ul>\n<li>A partir de la serie 5xxx, todos los controladores tienen soporte para RAID h\u00edbrido. La esencia de esta tecnolog\u00eda es que siempre se lee desde el SSD, cuando hay un espejo, uno de los discos es un SSD.<\/li>\n<li>5xxxQ, por ejemplo, el 5805ZQ. Estos controladores soportan MaxCache 1.0. Solo cach\u00e9 de lectura.<\/li>\n<li>6xxQ, por ejemplo, el 6805Q. MaxCache 2.0. Cach\u00e9 de lectura y escritura.<\/li>\n<li>7xxQ, por ejemplo, el 7805Q. MaxCache 3.0. Cach\u00e9 de lectura y escritura.<\/li>\n<li>8xxQ casi no tiene sentido usarlo para prop\u00f3sitos de actualizaci\u00f3n debido a los altos precios.<\/li>\n<\/ul>\n<p>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/pc-administrator\/blog\/319214\/\">Art\u00edculo sobre cach\u00e9 en SSD en Habr (controladores y sistemas operativos).<\/a><\/noindex><\/p>\n<h3>Tecnolog\u00edas de software de cach\u00e9 en SSD<\/h3>\n<p>\nNo voy a describir estas tecnolog\u00edas. Pr\u00e1cticamente en cualquier sistema operativo son soportadas hoy en d\u00eda. Recuerdo que al usar btrfs, autom\u00e1ticamente redirige las solicitudes de lectura al dispositivo con la cola m\u00e1s corta, es decir, el SSD.<\/p>\n<h2>SSD SATA III en interfaz SATA II<\/h2>\n<p>\nDado que no siempre hay posibilidades y fondos para un nuevo controlador, surge la pregunta de cu\u00e1n bien funcionan los SSD SATA III en la antigua interfaz SATA II.<\/p>\n<p>Realizaremos una peque\u00f1a prueba. Nuestro sujeto de prueba ser\u00e1 un SSD SATA III Intel S3710 de 400GB.<\/p>\n<p>Lectura aleatoria, IOPS<br \/>\nLatencia de lectura promedio, ms<br \/>\nEscritura aleatoria, IOPS<br \/>\nLatencia de escritura promedio, ms<br \/>\nLectura lineal, MB\/s<br \/>\nEscritura lineal, MB\/s<\/p>\n<p>SATA II<br \/>\n21241<br \/>\n2<br \/>\n13580<br \/>\n4<br \/>\n282<br \/>\n235<\/p>\n<p>SATA III<br \/>\n68073<br \/>\n0.468<br \/>\n61392<br \/>\n0.52<br \/>\n514<br \/>\n462<\/p>\n<p>\n<b class=\"spoiler_title\">Comandos utilizados para probar la velocidad<\/b><\/p>\n<pre><code class=\"bash\">fio --name LinRead --eta-newline=5s --filename=\/dev\/sda --rw=read --size=500m --io_size=10g --blocksize=1024k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=1 --runtime=60 --group_reporting\n\nfio --name LinWrite --eta-newline=5s --filename=\/dev\/sda --rw=write --size=500m --io_size=10g --blocksize=1024k --ioengine=libaio --fsync=10000 --iodepth=32 --direct=1 --numjobs=1 --runtime=60 --group_reporting\n\nfio --name RandRead --eta-newline=5s --filename=\/dev\/sda --rw=randread --size=500m --io_size=10g --blocksize=4k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=4 --runtime=60 --group_reporting\n\nfio --name RandWrite --eta-newline=5s --filename=\/dev\/sda --rw=randwrite --size=500m --io_size=10g --blocksize=4k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=4 --runtime=60 --group_reporting\n<\/code><\/pre>\n<p>Como se puede ver, la diferencia en la velocidad lineal, IOPS y latencias es bastante notable, por lo que tiene sentido utilizar solo la interfaz SATA III, y si no est\u00e1 disponible, instalar un controlador.<\/p>\n<p>Para ser justos, dir\u00e9 que en <noindex><a rel=\"nofollow\" href=\"http:\/\/www.thg.ru\/storage\/ustanovka_ssd_v_sistemu_s_sata_3_gbits_test\/ustanovka_ssd_v_sistemu_s_sata_3_gbits_test-01.html\">otros experimentos<\/a><\/noindex> La diferencia en la velocidad de lectura y escritura aleatoria fue m\u00ednima. Es posible que esta gran diferencia en IOPS entre SATA II y SATA III se deba a que ten\u00eda un controlador SATA II muy problem\u00e1tico o a un controlador con algunos errores.<\/p>\n<p>Sin embargo, el hecho es que es necesario verificar la velocidad de SATA II; tal vez su controlador sea igual de lento. En este caso, es esencial cambiar al controlador SATA III.<\/p>\n<h2>SSD PCIe en un bus PCI-e 2.0 o 1.0<\/h2>\n<p>\nComo se sabe, los SSD m\u00e1s r\u00e1pidos son los PCI-e NVMe, que no est\u00e1n limitados por los protocolos SAS o SATA.<\/p>\n<p>Sin embargo, al instalar SSD PCI-e modernos, hay que tener en cuenta que la mayor\u00eda de ellos utilizan solo 4 l\u00edneas PCI-e, generalmente PCI-e 3.0 o 3.1.<\/p>\n<p>Ahora veamos la tabla de velocidades del bus PCI-e.<\/p>\n<p>Ancho de banda de PCI Express, Gbytes\/s<\/p>\n<p>A\u00f1o <br \/>\n lanzamientos<\/p>\n<p>Versi\u00f3n<br \/>\nPCI Express<\/p>\n<p>Codificaci\u00f3n<\/p>\n<p>Velocidad<br \/>\ntransferencias<\/p>\n<p>Ancho de banda en x l\u00edneas<\/p>\n<p>\u00d74<br \/>\n\u00d78<br \/>\n\u00d716<\/p>\n<p>2002<br \/>\n1.0<br \/>\n8b\/10b<\/p>\n<p>0.50 Gbytes\/s<br \/>\n1.0 Gbytes\/s<br \/>\n2.0 Gbytes\/s<br \/>\n4.0 Gbytes\/s<\/p>\n<p>2007<br \/>\n2.0<br \/>\n8b\/10b<\/p>\n<p>1.0 Gbytes\/s<br \/>\n2.0 Gbytes\/s<br \/>\n4.0 Gbytes\/s<br \/>\n8.0 Gbytes\/s<\/p>\n<p>2010<br \/>\n3.0<br \/>\n128b\/130b<\/p>\n<p>1.97 Gbytes\/s<br \/>\n3.94 Gbytes\/s<br \/>\n7.88 Gbytes\/s<br \/>\n15.8 Gbytes\/s<\/p>\n<p>Al instalar un SSD PCI 3.0 x4 en un bus PCI-e 2.0, funcionar\u00e1 en el mismo n\u00famero de l\u00edneas pero a una velocidad considerablemente menor. Hay un problema, ya que las velocidades lineales de los SSD PCI-e modernos superan el ancho de banda del bus PCI-e 2.0 y, incluso m\u00e1s, del PCI-e 1.0.<\/p>\n<h3>SSD M.2 y adaptador PCI-e<\/h3>\n<p>Hay opciones de mejora bastante buenas, como comprar un adaptador por 10 d\u00f3lares y colocar un SSD M.2 en el servidor, pero nuevamente, para buenos SSD habr\u00e1 una reducci\u00f3n de velocidades (especialmente en PCI-e 1.0), y los SSD M.2 no siempre est\u00e1n preparados para cargas de trabajo en servidores: alta resistencia al desgaste, protecci\u00f3n de alimentaci\u00f3n y estabilidad de las caracter\u00edsticas de velocidad debido al llenado del cach\u00e9 SLC en modelos econ\u00f3micos.<\/p>\n<p>Por lo tanto, este m\u00e9todo solo puede ser adecuado para un servidor con un bus PCI-e 2.0 y ocupado en tareas no cr\u00edticas.<\/p>\n<h3>SSD PCI-E 2.0 x8<\/h3>\n<p>\nLa mejora m\u00e1s econ\u00f3micamente l\u00f3gica es el uso de SSD PCI-E 2.0 x8 para servidores con bus PCI-e 1.0 (ancho de banda de hasta 2 GB\/s) y PCI-e 2.0 (hasta 4 GB\/s).<\/p>\n<p>Este tipo de SSD para servidores se puede comprar muy barato tanto en diversos mercados como en subastas en l\u00ednea, incluidos en Rusia.<\/p>\n<p>He compilado una tabla de estos SSD moralmente obsoletos que acelerar\u00e1n perfectamente su servidor viejo. Al final de la tabla he a\u00f1adido algunos SSD con interfaz PCI-E 3.0 x8. Tal vez tenga suerte y los encuentre a un precio razonable.<\/p>\n<p>Nombre<br \/>\nTB<br \/>\nPBW<br \/>\nPCI-E<br \/>\n4k lectura iops, K<br \/>\n4k escritura iops, K<br \/>\nlectura, MB\/s<br \/>\nescritura, MB\/s<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusionio_iodrive2_duo_mlc_application_accelerator_review\">Fusion-io ioDrive II DUO MLC<\/a><\/noindex><br \/>\n2.4<br \/>\n32.5<br \/>\n2.0 x8<br \/>\n480<br \/>\n490<br \/>\n3000<br \/>\n2500<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SANDISK FUSION IOMEMORY SX350-1300<\/a><\/noindex><br \/>\n1.3<br \/>\n4<br \/>\n2.0 x8<br \/>\n225<br \/>\n345<br \/>\n2800<br \/>\n1300<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_px600_review\">SANDISK FUSION IOMEMORY PX600-1300<\/a><\/noindex><br \/>\n1.3<br \/>\n16<br \/>\n2.0 x8<br \/>\n235<br \/>\n375<br \/>\n2700<br \/>\n1700<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SANDISK FUSION IOMEMORY SX350-1600<\/a><\/noindex><br \/>\n1.6<br \/>\n5.5<br \/>\n2.0 x8<br \/>\n270<br \/>\n375<br \/>\n2800<br \/>\n1700<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_sx300_review\">SanDisk Fusion ioMemory SX300-3200<\/a><\/noindex><br \/>\n3.2<br \/>\n11<br \/>\n2.0 x8<br \/>\n345<br \/>\n385<br \/>\n2700<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SanDisk Fusion ioMemory SX350-3200<\/a><\/noindex><br \/>\n3.2<br \/>\n11<br \/>\n2.0 x8<br \/>\n345<br \/>\n385<br \/>\n2800<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_px600_review\">SANDISK FUSION IOMEMORY PX600<\/a><\/noindex><br \/>\n2.6<br \/>\n32<br \/>\n2.0 x8<br \/>\n350<br \/>\n385<br \/>\n2700<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/support.huawei.com\/enterprise\/en\/doc\/EDOC1000052593?section=j005\">Huawei ES3000 V2<\/a><\/noindex><br \/>\n1,6<br \/>\n8,76<br \/>\n2.0 x8<br \/>\n395<br \/>\n270<br \/>\n1550<br \/>\n1100<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/support.huawei.com\/enterprise\/en\/doc\/EDOC1000052593?section=j005\">Huawei ES3000 V2<\/a><\/noindex><br \/>\n3,2<br \/>\n17,52<br \/>\n2.0 x8<br \/>\n770<br \/>\n230<br \/>\n3100<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.emc.com\/collateral\/data-sheet\/h11411-xtremsf-ds.pdf\">EMC XtremSF<\/a><\/noindex><br \/>\n2,2<br \/>\n\u00a0<br \/>\n2.0 x8<br \/>\n340<br \/>\n110<br \/>\n2700<br \/>\n1000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/virident_flashmax_ii_mlc_application_accelerator_review_22tb\">HGST Virident FlashMAX II<\/a><\/noindex><br \/>\n2,2<br \/>\n33<br \/>\n2.0 x8<br \/>\n350<br \/>\n103<br \/>\n2700<br \/>\n1000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/documents.westerndigital.com\/\/content\/dam\/doc-library\/en_us\/assets\/public\/western-digital\/product\/hgst\/general-docs\/data-sheet-flashmax-pcie.pdf\">HGST Virident SSD FlashMAX II<\/a><\/noindex><br \/>\n4,8<br \/>\n10.1<br \/>\n2.0 x8<br \/>\n269<br \/>\n51<br \/>\n2600<br \/>\n900<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/documents.westerndigital.com\/\/content\/dam\/doc-library\/en_us\/assets\/public\/western-digital\/product\/hgst\/general-docs\/data-sheet-flashmax-pcie.pdf\">HGST Virident FlashMAX III<\/a><\/noindex><br \/>\n2,2<br \/>\n7.1<br \/>\n2.0 x8<br \/>\n531<br \/>\n59<br \/>\n2700<br \/>\n1400<\/p>\n<p>Dell Micron P420M<br \/>\n1.4<br \/>\n9.2<br \/>\n2.0 x8<br \/>\n750<br \/>\n95<br \/>\n3300<br \/>\n630<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/micron_p420m_enterprise_pcie_ssd_review\">Micron P420M<\/a><\/noindex><br \/>\n1.4<br \/>\n9.2<br \/>\n2.0 x8<br \/>\n750<br \/>\n95<br \/>\n3300<br \/>\n630<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.anandtech.com\/show\/10890\/hgst-ultrastar-sn200-accelerator-768-tb-capacity-61-gbs-read-speed-12m-iops\">HGST SN260<\/a><\/noindex><br \/>\n1.6<br \/>\n25.10<br \/>\n3.0 x8<br \/>\n1200<br \/>\n200<br \/>\n6170<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.anandtech.com\/show\/10890\/hgst-ultrastar-sn200-accelerator-768-tb-capacity-61-gbs-read-speed-12m-iops\">HGST SN260<\/a><\/noindex><br \/>\n3,2<br \/>\n17,52<br \/>\n3.0 x8<br \/>\n1200<br \/>\n200<br \/>\n6170<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/ark.intel.com\/content\/www\/ru\/ru\/ark\/products\/88731\/intel-ssd-dc-p3608-series-1-6tb-1-2-height-pcie-3-0-x8-20nm-mlc.html\">Intel P3608<\/a><\/noindex><br \/>\n3,2<br \/>\n17,5<br \/>\n3.0 x8<br \/>\n850<br \/>\n80<br \/>\n4500<br \/>\n2600<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.kingston.com\/datasheets\/DCP1000_us.pdf\">Kingston DCP1000<\/a><\/noindex><br \/>\n3,2<br \/>\n2,78<br \/>\n3.0 x8<br \/>\n1000<br \/>\n180<br \/>\n6800<br \/>\n6000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/docs.oracle.com\/cd\/E65386_01\/html\/E65387\/gokdw.html#scrolltoc\">Oracle F320<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n750<br \/>\n120<br \/>\n5500<br \/>\n1800<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/global.semi.static\/PM1725_NVMe_PCIe_SSD_Samsung_2016-1.pdf\">Samsung PM1725<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n1000<br \/>\n120<br \/>\n6000<br \/>\n2000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/ssd\/enterprise-ssd\/MZPLL3T2HMLS\/\">Samsung PM1725a<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n1000<br \/>\n180<br \/>\n6200<br \/>\n2600<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/ssd\/enterprise-ssd\/MZPLL3T2HAJQ\/\">Samsung PM1725b<\/a><\/noindex><br \/>\n3.2<br \/>\n18<br \/>\n3.0 x8<br \/>\n980<br \/>\n180<br \/>\n6200<br \/>\n2600<\/p>\n<p>\n<img decoding=\"async\" alt=\"Actualizaci\u00f3n del subsistema de disco de un servidor antiguo con bus PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/369c72c6f028b915a199e85fc3de3819.jpg\" style=\"display:block;margin: 0 auto;\" \/>Entre estos SSD, Fusion ioMemory destaca. Su director cient\u00edfico <noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/Fusion-io\">Fusion<\/a><\/noindex> fue <noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/%D0%92%D0%BE%D0%B7%D0%BD%D1%8F%D0%BA,_%D0%A1%D1%82%D0%B8%D0%B2\">Steve Wozniak<\/a><\/noindex>. Luego, esta empresa fue adquirida por SanDisk por 1.2 mil millones de d\u00f3lares. En su momento, costaban desde $50,000 cada uno. Ahora se pueden comprar por unos cientos de d\u00f3lares en nuevo estado por un disco de capacidad de 1TB o m\u00e1s.<\/p>\n<p>Si uno observa la tabla, se ve que tienen un n\u00famero bastante alto de IOPS en escritura casi igual al n\u00famero de IOPS en lectura. Considerando su precio actual, en mi opini\u00f3n, estos SSD merecen atenci\u00f3n. <\/p>\n<p>Sin embargo, tienen algunas particularidades:<\/p>\n<ol>\n<li>No pueden ser de arranque.<\/li>\n<li>Se necesita un controlador para su uso. Hay controladores pr\u00e1cticamente para todo, pero para las versiones m\u00e1s recientes de Linux tendr\u00e1n que compilarse.<\/li>\n<li>El tama\u00f1o \u00f3ptimo del sector es 4096 bytes. (Tambi\u00e9n se admite 512)<\/li>\n<li>El controlador en el peor de los escenarios puede consumir bastante RAM (con un tama\u00f1o de sector de 512 bytes).<\/li>\n<li>La velocidad de funcionamiento depende de la velocidad del procesador, por lo que es mejor desconectar las tecnolog\u00edas de ahorro de energ\u00eda. Esto es tanto una ventaja como una desventaja, ya que con un procesador potente el dispositivo puede funcionar incluso m\u00e1s r\u00e1pido de lo que indican las especificaciones.<\/li>\n<li>Necesita un buen enfriamiento. Para servidores esto no deber\u00eda ser un problema.<\/li>\n<li>No se recomienda para ESXi, ya que ESXi prefiere discos con sector 512N, lo que puede resultar en un alto consumo de memoria del controlador.<\/li>\n<li>Las versiones de marca de estos SSD generalmente no son soportadas por los vendedores hasta el \u00faltimo controlador de SanDisk (marzo de 2019).<\/li>\n<\/ol>\n<p>\nRealic\u00e9 pruebas de Fusion ioMemory en comparaci\u00f3n con un SSD de servidor bastante moderno Intel P3700 PCI-E 3.0 x8 (este \u00faltimo cuesta alrededor de 4 veces m\u00e1s que el Fusion de capacidad similar). Tambi\u00e9n se puede ver cu\u00e1nto se reduce la velocidad debido al bus x4.<\/p>\n<p>Fusion PX600 1.3TB PCI-E 2.0 x8<br \/>\nIntel P3700 1.6TB PCI-E 3.0 x4<\/p>\n<p><img decoding=\"async\" alt=\"Actualizaci\u00f3n del subsistema de disco de un servidor antiguo con bus PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/7157ec6e43cac87fc0cdf5dd2887cfac.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<img decoding=\"async\" alt=\"Actualizaci\u00f3n del subsistema de disco de un servidor antiguo con bus PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/f5db5f37b300332bd787d5b2fe57b67e.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>\nS\u00ed, la velocidad de lectura lineal se reduce definitivamente en el Intel P3700. Seg\u00fan las especificaciones, deber\u00eda ser 2800 MB\/s, pero tenemos 1469 MB\/s. Aunque en general se puede decir que se pueden usar SSD de servidor PCI-E 3.0 x4 con un bus PCI-e 2.0, siempre que se logre obtener a un precio razonable.<\/p>\n<h3>Conclusiones<\/h3>\n<p>\nSe puede potenciar el subsistema de disco del antiguo servidor con un bus PCI-E 1.0 o 2.0 utilizando SSD que pueden aprovechar 8 l\u00edneas PCI-E, lo que proporciona un ancho de banda de hasta 4 GB\/s (PCI-E 2.0) o 2 GB\/s (PCI-E 1.0). La manera m\u00e1s econ\u00f3mica de hacerlo es utilizando SSD PCI-E 2.0 que est\u00e1n moralmente obsoletos.<\/p>\n<p>Tambi\u00e9n hay opciones intermedias simples relacionadas con la compra de la clave CacheCade para controladores LSI o la sustituci\u00f3n del controlador Adaptec por la versi\u00f3n Q.<\/p>\n<p>Y un m\u00e9todo completamente obvio es comprar un controlador RAID SATA III para que los SSD funcionen a plena velocidad y poder utilizar todo lo que requiere rapidez.<br \/>\n<br \/>Fuente: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/454222\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u041f\u043e\u0447\u0435\u043c\u0443 \u0442\u0435\u043c\u043e\u0439 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0432\u044b\u0431\u0440\u0430\u043d \u0430\u043f\u0433\u0440\u0435\u0439\u0434 \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b\u041f\u043e\u043d\u044f\u0442\u043d\u043e, \u0447\u0442\u043e \u0432 \u043f\u0435\u0440\u0432\u0443\u044e \u043e\u0447\u0435\u0440\u0435\u0434\u044c \u043d\u0443\u0436\u043d\u043e, \u043a\u0430\u043a \u043f\u0440\u0430\u0432\u0438\u043b\u043e: \u0423\u0432\u0435\u043b\u0438\u0447\u0438\u0442\u044c \u043e\u043f\u0435\u0440\u0430\u0442\u0438\u0432\u043d\u0443\u044e \u043f\u0430\u043c\u044f\u0442\u044c. \u042d\u0442\u043e \u043d\u0430\u0441\u0442\u043e\u043b\u044c\u043a\u043e \u043e\u0447\u0435\u0432\u0438\u0434\u043d\u044b\u0439 \u0445\u043e\u0434, \u0447\u0442\u043e \u044f \u0434\u0430\u0436\u0435 \u043d\u0435 \u0441\u0447\u0451\u043b \u043d\u0443\u0436\u043d\u044b\u043c \u043f\u0438\u0441\u0430\u0442\u044c \u043e\u0431 \u044d\u0442\u043e\u043c \u0432 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0435 \u041f\u043e\u0441\u0442\u0430\u0432\u0438\u0442\u044c \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440(\u044b) \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u043e\u0431\u0430 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u0430 \u043d\u0430 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0432\u0435\u0440\u0441\u0438\u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u044b\u0435 \u0441\u043e\u043a\u0435\u0442\u0430\u043c\u0438 \u0441\u0435\u0440\u0432\u0435\u0440\u0430. \u0414\u043b\u044f \u0441\u0442\u0430\u0440\u044b\u0445 \u0441\u0435\u0440\u0432\u0435\u0440\u043e\u0432, \u0447\u0442\u043e \u043f\u0430\u043c\u044f\u0442\u044c, \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u044b, \u043a\u0430\u043a [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":26262,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-34884","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2 - aioseo.com -->\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/es\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47Upgrade \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0442\u0430\u0440\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 \u0441 \u0448\u0438\u043d\u043e\u0439 PCIe 1.0 \u2014 2.0 | ProHoster\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/es\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:01:01+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:01:01+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Mejora del subsistema de disco de un antiguo servidor con bus PCIe 1.0 - 2.0 | ProHoster","description":"","canonical_url":"https:\/\/prohoster.info\/es\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"es_ES","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47Upgrade \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0442\u0430\u0440\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 \u0441 \u0448\u0438\u043d\u043e\u0439 PCIe 1.0 \u2014 2.0 | ProHoster","og:url":"https:\/\/prohoster.info\/es\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:01:01+00:00","article:modified_time":"2019-10-31T19:01:01+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"34884","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-21 20:58:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 02:13:27","updated":"2026-01-21 20:58:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/posts\/34884","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/comments?post=34884"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/posts\/34884\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/media\/26262"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/media?parent=34884"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/categories?post=34884"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/tags?post=34884"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}