{"id":56401,"date":"2020-02-12T00:00:00","date_gmt":"2020-02-11T21:00:00","guid":{"rendered":"https:\/\/prohoster.info\/blog\/blog_prohoster\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit"},"modified":"2020-02-18T14:04:41","modified_gmt":"2020-02-18T11:04:41","slug":"besperebojniki-apc-smart-ups-i-kak-ih-gotovit","status":"publish","type":"post","link":"https:\/\/prohoster.info\/es\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","title":{"rendered":"UPS APC Smart UPS y c\u00f3mo prepararlos","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Entre la diversidad de SAI, los m\u00e1s comunes en servidores de nivel b\u00e1sico son los Smart UPS de APC (ahora Schneider Electric). Su gran fiabilidad y bajo precio en el mercado secundario hacen que los administradores de sistemas los utilicen sin pensarlo, llenando los racks con estos SAI e intentando obtener el m\u00e1ximo beneficio de los equipos de hace 10-15 a\u00f1os simplemente reemplazando las bater\u00edas. Desafortunadamente, esto no siempre produce los resultados esperados. Vamos a analizar qu\u00e9 y c\u00f3mo se debe hacer para que su SAI funcione \"como nuevo\".<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<h3>Selecci\u00f3n de bater\u00edas<\/h3>\n<p>\nTodos los art\u00edculos y temas en los foros sobre la selecci\u00f3n de bater\u00edas para SAI, a menudo recuerdan las discusiones sobre la elecci\u00f3n de aceite de motor para coches\/motos. Intentaremos no caer en eso y entender los principios b\u00e1sicos de selecci\u00f3n de bater\u00edas tomando como ejemplo al fabricante CSB. <\/p>\n<p>Vemos que tienen una gran variedad de l\u00edneas de bater\u00edas: GP, GPL, HR, HRL, UPS, TPL. <\/p>\n<p>Comenzamos a leer: GP, GPL \u2014 bater\u00edas de uso universal <b>para corrientes de descarga bajas y medias.<\/b>. Son recomendadas para sistemas de seguridad y contra incendios, as\u00ed como SAI. No nos sirven. Aunque justo son las que m\u00e1s se compran, sin tomarse la molestia de estudiar sus caracter\u00edsticas. <\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS y c\u00f3mo prepararlos\" src=\"\/wp-content\/uploads\/2020\/02\/8daafaf7943d755075773d981e84d94c.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nLa serie HR consiste en bater\u00edas de alta capacidad y que permiten descargas profundas (hasta el 11% de la capacidad restante), especialmente \u00fatiles cuando se requieren altas corrientes de descarga. La diferencia de las bater\u00edas \"H\" es su dise\u00f1o especial de rejilla, que permite aumentar la potencia de salida en un 20%. Son las m\u00e1s adecuadas para su uso en instalaciones de energ\u00eda potentes y SAI.<\/p>\n<p>La letra \"L\" en la serie indica que son bater\u00edas de mayor duraci\u00f3n (Long Life) en modo de operaci\u00f3n de reserva de hasta 10 a\u00f1os.<\/p>\n<p>Por \u00faltimo, la serie UPS es una bater\u00eda dise\u00f1ada especialmente para su uso en condiciones de altas corrientes con un corto tiempo de descarga.<\/p>\n<p>Llev\u00e9 mucho tiempo eligiendo entre UPS y HRL, pero decid\u00ed optar por HRL. Desafortunadamente, decir c\u00f3mo se comportar\u00e1n en un uso prolongado solo se podr\u00e1 saber dentro de cinco a\u00f1os, y el necroposteo no es muy bien visto. As\u00ed que consideraremos que es mi elecci\u00f3n personal y no pretendo imponerla. Pero deben entender que es necesario elegir bater\u00edas de alta corriente, ya que deben ser capaces de entregar toda la capacidad acumulada en 20-30 minutos. <\/p>\n<h3>Selecci\u00f3n de la configuraci\u00f3n de bater\u00edas<\/h3>\n<p>\nDado que se utilizan varias bater\u00edas en la ensambladura, es altamente recomendable que tengan caracter\u00edsticas id\u00e9nticas. Un solo acumulador deficiente har\u00e1 que toda la unidad funcione muy por debajo de las expectativas.<\/p>\n<p>Hace unos 5 a\u00f1os, descubr\u00ed la empresa Rostov \u00abBasti\u00f3n\u00bb, que produce medidores de capacidad de bater\u00eda bajo la marca \u00abSkat\u00bb. No me atrevo a afirmar que la precisi\u00f3n de las mediciones sea perfecta, pero para evaluar el estado de la bater\u00eda: ideal-viva-a\u00fan sirve-muerta, este medidor es m\u00e1s que suficiente. <\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS y c\u00f3mo prepararlos\" src=\"\/wp-content\/uploads\/2020\/02\/7390b5c6865ebe74998c6d6494c4e548.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nEn principio, se puede medir la capacidad simplemente cargando y descargando utilizando un cron\u00f3metro, una l\u00e1mpara de automoci\u00f3n de 21W (que proporciona una carga de aproximadamente 1A) y un medidor, pero esto es lento y, a menudo, da pereza.<\/p>\n<p>En el peor de los casos, simplemente intentamos instalar bater\u00edas nuevas de la misma partida y esperar que tengamos suerte. <\/p>\n<h3>La electricidad es la ciencia de los contactos.<\/h3>\n<p>\nUn mal contacto en un ensamblaje de 4 bater\u00edas anular\u00e1 todos sus esfuerzos, as\u00ed que desmontamos la unidad con mucho cuidado. Generalmente, en los UPS se utilizan conectores de bater\u00eda con bloqueos, que al ser extra\u00eddos pueden f\u00e1cilmente romperse. Por lo tanto, tomamos un peque\u00f1o destornillador plano, lo insertamos en el conector como en la foto y lo removemos con cuidado, sin hacer esfuerzos excesivos. Como sugiri\u00f3 un colega en el comentario: simplemente hay que tirar del capuch\u00f3n de pl\u00e1stico, no del cable. El conector se quita con un ligero clic.<\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS y c\u00f3mo prepararlos\" src=\"\/wp-content\/uploads\/2020\/02\/07d704acf5b9c5a92b2ddf6e05f89f2a.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nEn cuanto a la correcta conexi\u00f3n de los cables, creo que no es necesario abundar en ello. Si has abierto el UPS, seguramente conoces el principio de conexi\u00f3n en serie de las bater\u00edas. Y para los dem\u00e1s: papel y bol\u00edgrafo o un smartphone con c\u00e1mara. Al finalizar el ensamblaje, por si acaso medimos con el tester el voltaje en el ensamblaje y lo comparamos con lo que deber\u00eda ser, seg\u00fan la cantidad de bater\u00edas.<\/p>\n<h3>\u00abHice todo como estaba escrito, pero no sirvi\u00f3\u00bb<\/h3>\n<p>\nAhora comienza lo m\u00e1s interesante. El UPS, durante su funcionamiento, realiza peri\u00f3dicamente (generalmente cada 7 o 14 d\u00edas, seg\u00fan la configuraci\u00f3n) una breve calibraci\u00f3n de la bater\u00eda. Cambia a modo de funcionamiento con bater\u00edas y mide el voltaje de inmediato y despu\u00e9s de un corto tiempo. El resultado es un coeficiente corrector de \"vitalidad de la bater\u00eda\" que se registra. A medida que la bater\u00eda se agota, el estado de este registro disminuye gradualmente. En funci\u00f3n de esto, el UPS calcula el tiempo restante de funcionamiento con bater\u00edas. Y en un momento dado, al darse cuenta de que las cosas van mal, el UPS enciende un indicador que exige el reemplazo de la bater\u00eda. Pero, cuando realizamos el cambio, el UPS no lo sabe. El estado del registro \"vitalidad de la bater\u00eda\" permanece igual. Necesitamos corregirlo.<\/p>\n<p>Hay dos caminos. El primer camino, sencillo y r\u00e1pido, es realizar una calibraci\u00f3n completa del UPS. Para ello, es necesario cargarlo por encima del 35% y comenzar la calibraci\u00f3n, por ejemplo, desde el programa PowerChute. Esto funciona aproximadamente en la mitad de los casos. \u00bfPor qu\u00e9 no siempre? Es un misterio. Por lo tanto, tomaremos el camino m\u00e1s largo, pero m\u00e1s confiable.<\/p>\n<p>Necesitaremos: un ordenador con puerto COM, un cable original (por ejemplo, 940-0024C), el programa UpsDiag 2.0 (para la seguridad de su UPS, un colega recomienda mejor usar apcfix en modo gratuito. No puedo decir nada al respecto, salvo que no recomiendo en UpsDiag presionar nada m\u00e1s que la correcci\u00f3n del registro 0. <i>especialmente el bot\u00f3n de correcci\u00f3n autom\u00e1tica de errores de la bater\u00eda.<\/i>) y <noindex><a rel=\"nofollow\" href=\"http:\/\/www.apcupsd.com\/manual\/manual.html#configuring-your-eeprom\">tabla de valores de calibraci\u00f3n<\/a><\/noindex>. Nos interesa el valor del registro 0. En la tabla se indica el valor para bater\u00edas ideales y esf\u00e9ricas en un vac\u00edo. Cualquier bater\u00eda real dar\u00e1 un valor menor despu\u00e9s de la calibraci\u00f3n, pero no mucho.<\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS y c\u00f3mo prepararlos\" src=\"\/wp-content\/uploads\/2020\/02\/93542115e332bece7803efac1c88a284.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nPor ejemplo, tomar\u00e9 un UPS real SUA1500RMI2U. En el momento del cambio de bater\u00eda, UpsDiag mostraba un valor de registro 0 - 42. Es decir, las bater\u00edas estaban muertas. El valor de calibraci\u00f3n de la tabla es A1. <\/p>\n<p>Comenzamos a corregir. Primero <b>retiramos la tarjeta de red del UPS<\/b>. La presencia de la tarjeta de red no te permitir\u00e1 corregir el registro. \u00bfPor qu\u00e9? Es una cuesti\u00f3n para los ingenieros de APC. Afortunadamente, se puede quitar mientras est\u00e1 en funcionamiento, sin apagar el UPS. <\/p>\n<p>Conectamos el cable, iniciamos UpsDiag, vamos a la pesta\u00f1a \u00abCalibraci\u00f3n\u00bb y verificamos el estado del registro 0. Anotamos en un papel, hacemos clic derecho sobre \u00e9l \u2013 Modificar. Lo elevamos al valor de la tabla de valores de calibraci\u00f3n \u2013 A1. Si en la tabla no est\u00e1 su UPS, en principio se puede elevar hasta FF. No pasa nada grave con eso, excepto que el UPS se sorprenda y muestre que est\u00e1 listo para soportar la carga hasta el segundo advenimiento. <\/p>\n<p>Luego, necesitamos esperar a que la bater\u00eda se cargue al 100%, cargar el UPS hasta un 35% o un poco m\u00e1s y ejecutar la calibraci\u00f3n. Al finalizar la calibraci\u00f3n, nuevamente observamos el valor en el registro 0 y lo comparamos con el anotado en el papel. En el SUA1500RMI2U mencionado arriba con nuevas bater\u00edas HRL1234W, el valor se convirti\u00f3 en 98, lo cual no est\u00e1 muy lejos del calibrado A1.<\/p>\n<p>Despu\u00e9s de todo, dejamos que se cargue nuevamente al 100%, desconectamos el cable COM, volvemos a conectar la tarjeta de red y deseamos al UPS una larga y feliz vida en beneficio de nuestro rack de servidores.<\/p>\n<p>Por cierto, las tarjetas de red, como la AP9619, tambi\u00e9n han bajado demasiado de precio en el mercado secundario. Pero c\u00f3mo configurarlas (reinicio de contrase\u00f1a, actualizaci\u00f3n de firmware, configuraci\u00f3n) es un tema para otro art\u00edculo.<br \/>\n<br \/>Fuente: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/487802\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric). \u0412\u0435\u043b\u0438\u043a\u043e\u043b\u0435\u043f\u043d\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0438\u0437\u043a\u0430\u044f \u0446\u0435\u043d\u0430 \u043d\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u043c \u0440\u044b\u043d\u043a\u0435, \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u044e\u0442 \u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u0441\u0438\u0441\u0430\u0434\u043c\u0438\u043d\u044b, \u043e\u0441\u043e\u0431\u043e \u043d\u0435 \u0437\u0430\u0434\u0443\u043c\u044b\u0432\u0430\u044f\u0441\u044c, \u0443\u0442\u044b\u043a\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u043e\u0439\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u043c\u0438 \u0418\u0411\u041f \u0438 \u043f\u044b\u0442\u0430\u044e\u0442\u0441\u044f \u0432\u044b\u0442\u044f\u043d\u0443\u0442\u044c \u0441 \u0436\u0435\u043b\u0435\u0437\u043e\u043a 10-15 \u043b\u0435\u0442\u043d\u0435\u0439 \u0434\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0443\u043c \u043f\u0440\u043e\u0444\u0438\u0442\u0430 \u0431\u0430\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u043e\u0439 \u0430\u043a\u043a\u0443\u043c\u0443\u043b\u044f\u0442\u043e\u0440\u043e\u0432. \u041a \u0441\u043e\u0436\u0430\u043b\u0435\u043d\u0438\u044e \u043d\u0435 \u0432\u0441\u0435\u0433\u0434\u0430 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-56401","post","type-post","status-publish","format-standard","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/es\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/es\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-02-11T21:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-02-18T11:04:41+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47UPS APC Smart, y c\u00f3mo configurarlos | ProHoster","description":"Entre toda la diversidad de UPS, los m\u00e1s comunes en servidores de nivel inicial son los Smart UPS de la marca APC (ahora \u2013 Schneider Electric).","canonical_url":"https:\/\/prohoster.info\/es\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"es_ES","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster","og:description":"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).","og:url":"https:\/\/prohoster.info\/es\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-02-11T21:00:00+00:00","article:modified_time":"2020-02-18T11:04:41+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"56401","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 19:25:39","updated":"2022-09-29 13:07:34","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/posts\/56401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/comments?post=56401"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/posts\/56401\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/media?parent=56401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/categories?post=56401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/es\/wp-json\/wp\/v2\/tags?post=56401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}