{"id":35321,"date":"2019-10-31T22:03:38","date_gmt":"2019-10-31T19:03:38","guid":{"rendered":"https:\/\/prohoster.info\/blog\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod\/"},"modified":"2019-10-31T22:03:38","modified_gmt":"2019-10-31T19:03:38","slug":"kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod","status":"publish","type":"post","link":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod","title":{"rendered":"Kappid, moodulid v\u00f5i plokid \u2013 mida valida andmehalduss\u00fcsteemi energiahalduseks?","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Kappid, moodulid v\u00f5i plokid \u2013 mida valida andmehalduss\u00fcsteemi energiahalduseks?\" src=\"\/wp-content\/uploads\/2019\/06\/a6e891f08c0ebddac7c7b465fc404858.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<p>Kaasaegsed andmekeskused n\u00f5uavad hoolikat l\u00e4henemist elektritoitele. On oluline j\u00e4lgida koormuste seisundit ja hallata seadmete \u00fchendusi. Seda saab teha, kasutades kappide, moodulite v\u00f5i elektritootmisjaotustblokkide abi. Milline energiaseadmestik sobib k\u00f5ige paremini konkreetsete olukordade jaoks, selle kohta r\u00e4\u00e4gime meie postituses Delta lahenduste n\u00e4idete abil.<\/p>\n<p><noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<p>D\u00fcnaamiliselt areneva andmekeskuse energiatootmine osutub sageli keeruliseks \u00fclesandeks. T\u00e4iendavad seadmed riiulites, seadmete \u00fcleminek oote-re\u017eiimile v\u00f5i vastupidi, koormuse suurenemine viivad energiatootmise tasakaalu h\u00e4ireni, reaktiivv\u00f5imsuse kasvuni ja elektriv\u00f5rgu mitteoptimaalse t\u00f6\u00f6ni. Kaotuste v\u00e4ltimiseks, seadmete t\u00f5husaks t\u00f6\u00f6ks ning nende kaitsmiseks v\u00f5imalikest elektritoite probleemidest aitavad elektritootmisjaotuss\u00fcsteemid.<\/p>\n<p><\/p>\n<p>Elektritoitev\u00f5rkude projekteerimisel seisavad IT-spetsialistid sageli silmitsi valikuga kappide, moodulite ja elektritootmisjaotust blokkide vahel. L\u00f5ppkokkuv\u00f5ttes lahendavad k\u00f5ik kolm seadmekategooriat p\u00f5him\u00f5tteliselt samu \u00fclesandeid, kuid erinevatel tasanditel ja erineva valikute komplektiga.<\/p>\n<p><\/p>\n<h2>Elektritootmisjaotuskapp<\/h2>\n<p><\/p>\n<p>Elektritootmisjaotuskapp ehk PDC (power distribution cabinet) on elektritoite kontrollimise seade k\u00f5rgel tasemel. Kapp v\u00f5imaldab tasakaalustada energiatootmist k\u00fcmnete riiulite jaoks andmekeskuses, ning mitme kapi kasutamine annab v\u00f5imaluse juhtida suurte andmekeskuste t\u00f6\u00f6d. N\u00e4iteks selliseid lahendusi kasutavad mobiilioperaatorid \u2013 5000 riiulit varustada vajati rohkem kui 50 elektritootmisjaotuskappi. <noindex><a rel=\"nofollow\" href=\"https:\/\/www.deltapowersolutions.com\/ru-ru\/mcis\/success-story-delta-power-distribution-cabinets-serve-china-mobile-shanghai.php\">mis on paigaldatud China Mobile andmekeskuses<\/a><\/noindex> Shanghais.<\/p>\n<p><\/p>\n<p>Delta InfraSuite PDC kabinet, mille m\u00f5\u00f5tmed vastavad standardsele 19-tollisele kappile, sisaldab kahte rida \u00fchetaktilisi automaatkaitseelemente, mida kaitsevad t\u00e4iendavad katkemisnupud. Kabinet suudab j\u00e4lgida iga ahela vooluparametreid eraldi katkemisnupuga. Toitejaotuskapp on varustatud sisseehitatud h\u00e4daolukorra hoiatustega, mis teavitavad ebav\u00f5rdsest koormusest. Valikuna varustatakse Delta kapid t\u00e4iendavate transformaatoritega erinevate v\u00e4ljundpingete genereerimiseks ning impulssm\u00fcra kaitsemoodulitega, n\u00e4iteks neid, mis tekivad v\u00e4lku l\u00f6\u00f6misel. <\/p>\n<p><\/p>\n<p>Juhtimiseks saab kasutada sisseehitatud LCD-ekraani ning ka v\u00e4list energiat juhtimise s\u00fcsteemi, mis on \u00fchendatud j\u00e4rjestikuse RS232 liidese v\u00f5i SNMP kaudu. Seadme \u00fchendamine v\u00e4lisse v\u00f5rku toimub spetsiaalse InsightPower mooduli kaudu. See v\u00f5imaldab edastada keskserverisse teateid, juhtpaneeli andmeid ja jaotusv\u00f5rkude olekuparametreid. See on peamine komponent, mis v\u00f5imaldab kaugjuhtimist ja j\u00e4lgimist ning teavitab s\u00fcsteemiinseneride kriitiliste s\u00fcndmuste korral SNMP-ansamblite ja e-posti kaudu.<\/p>\n<p><\/p>\n<p>Andmekeskuse hooldust\u00f6\u00f6tajad saavad teada, milline faas on rohkem koormatud, ja saavad l\u00fclitada osa tarbijatest v\u00e4hem koormatud faasi v\u00f5i \u00f5igel ajal planeerida t\u00e4iendava seadme paigaldamist. Ekraanil j\u00f5uab j\u00e4lgida selliseid parameetreid nagu temperatuur, maapinna lekkevool ja pingetasakaalu olemasolu v\u00f5i puudumine. S\u00fcsteemi on sisseehitatud ajakiri, mis salvestab kuni 500 kabineti s\u00fcndmuse kirje, v\u00f5imaldades taastada vajaliku konfiguratsiooni v\u00f5i anal\u00fc\u00fcsida vigu, mis eelnesid h\u00e4daolukorra v\u00e4ljal\u00fclitamisele.<\/p>\n<p><\/p>\n<p>Delta mudelivaliku puhul on PDC \u00fchendatud kolmefaasilise v\u00f5rgu k\u00fclge ja t\u00f6\u00f6tab 220 V pingel, lubatud k\u00f5rvalekaldega kuni 15%. Seeria sisaldab mudelid, mille v\u00f5imsus on 80 kVA ja 125 kVA.<\/p>\n<p><\/p>\n<h2>Toitejaotuse moodulid<\/h2>\n<p><\/p>\n<p>Kui toitejaotuskabiin on eraldi kappidena, mida saab andmekeskuses \u00fcmber paigutada, siis modulaarsete s\u00fcsteemide abil on v\u00f5imalik paigaldada sarnast varustust otse racksidesse. Need nimetatakse RPDC (Rack Power Distribution Cabinet) ja need on v\u00e4ikesed jaotuskabiinid, mis v\u00f5tavad tavalises rackis 4U ruumi. Sarnaseid lahendusi kasutatakse internetifirmades, kellele on vajalik tagada v\u00e4ikese varustuse parki t\u00f6\u00f6kindlus. N\u00e4iteks on jaotuselehed paigaldatud andmekeskuse kaitse komplekssel lahendusel. <noindex><a rel=\"nofollow\" href=\"https:\/\/www.deltapowersolutions.com\/ru-ru\/mcis\/success-story-delta-infrasuite-ensures-the-continuous-operation-of-an-online-shop-in-germany.php\">\u00fche juhtiva e-kaubanduse ettev\u00f5tte<\/a><\/noindex> Saksamaal.<\/p>\n<p><\/p>\n<p>Kui r\u00e4\u00e4kida Delta seadmetest, v\u00f5ib \u00fche RPDC \u00fcksuse v\u00f5imsus olla 30, 50 v\u00f5i 80 kVA. \u00dches racks v\u00f5ib paigutada mitu moodulit, et tagada toide k\u00f5igile v\u00e4ikese andmekeskuse koormustele, v\u00f5i v\u00f5ib igas racksis paigutada \u00fche RPDC. Viimane valik sobib piisavalt v\u00f5imsate serverite toiteks, kellele on vajalik energiaedastuse kontroll ja toitejaotuse kohandamine vastavalt konfiguratsioonile ja koormusele. <\/p>\n<p><\/p>\n<p>Modulaarse s\u00fcsteemi plussiks on v\u00f5ime suurendada v\u00f5imsust koos andmekeskuse kasvamise ja laiendamisega. Kasutajad valivad tihti just RPDC, kui t\u00e4isv\u00e4\u00e4rtuslik kapp loob praeguse konfiguratsiooni jaoks 2\u20133 racksis liiga suure varu.<\/p>\n<p><\/p>\n<p>Iga moodul on varustatud puuteekraaniga, millel on praktiliselt samad juhtimisv\u00f5imalused, mis eraldi PDC-l, ning see toetab RS-232 liidesi ja nutikaarte kaugt\u00f6\u00f6tluseks. Jaotusmodulid kontrollivad voolu igas \u00fchendatud ahelas, teavitavad automaatselt h\u00e4daolukordadest ja toetavad juhtimisseadmeste kuuma vahetust. S\u00fcsteemi olekuandmed kantakse igap\u00e4evasesse ajakirja, mis v\u00f5ib hoida kuni 2000 kirjet.<\/p>\n<p><\/p>\n<h2>Toite jaotamise blokid<\/h2>\n<p><\/p>\n<p>Toitejaotusseadmed on selles kategoorias k\u00f5ige kompaktsed ja \u00f6konoomsemad s\u00fcsteemid. Need v\u00f5imaldavad juhtida varustuse t\u00f6\u00f6d \u00fche racksis, pakkudes teavet liinide ja koormuse seisundi kohta. N\u00e4iteks on selliseid seadmeid kasutatud <noindex><a rel=\"nofollow\" href=\"https:\/\/www.deltapowersolutions.com\/ru-ru\/mcis\/success-story-delta-develops-a-tailored-total-solution-for-miran-companys-data-center-in-st-petersburg.php\">andmekeskuse \"Miran\" varustamiseks<\/a><\/noindex>\u00bb Peterburis ja <noindex><a rel=\"nofollow\" href=\"https:\/\/www.deltapowersolutions.com\/ru-ru\/mcis\/success-story-delta-installs-infrastructure-solutions-at-the-russian-digital-enterprise-consortium.php\">katsel-usalduspunkt<\/a><\/noindex> digitaalse ettev\u00f5tte konsortsiumi Kesk-Venemaal.<\/p>\n<p><\/p>\n<p>Bloke on erinevates formaatides, kuid Zero-U tehnoloogial valmistatud mudelid paigutatakse samasse riiulisse, kus asub p\u00f5hiseade, kuid ei v\u00f5ta eraldi \"\u00fcksusi\" \u2013 need kinnitatakse konstruktsiooni elementidele spetsiaalsete kinnitusdetailide abil vertikaalselt v\u00f5i horisontaalselt. See t\u00e4hendab, et kui kasutate 42U riiulit, j\u00e4\u00e4b p\u00e4rast ploki paigaldamist teil t\u00e4pselt sama palju \u00fcksusi alles. Igal jaotamisplokil on oma alarmis\u00fcsteem: koormuse olemasolust v\u00f5i probleemidest teavitavad igas v\u00e4ljundjoones LED-indikaatorid. Delta plokid on varustatud RS232 liidese ja neid saab \u00fchendada j\u00e4lgimiss\u00fcsteemidega SNMP kaudu, t\u00e4pselt nagu kabinetid ja toitejaotmismoodulid.<\/p>\n<p><\/p>\n<p>M\u00f5\u00f5tmis- ja p\u00f5hijagamisplokid saab paigaldada otse riiulisse, nii Delta standardehitusele kui ka teiste tootjate riiulitele. See on v\u00f5imalik universaalsete kinnitusdetailide komplekti t\u00f5ttu. Toitejaotamisplokke saab paigaldada vertikaalselt ja horisontaalselt ning kasutada nii \u00fchefaasilise kui ka kolmefaasilise toiteallika puhul. Delta jaotamisplokkide maksimaalne voolutugevus on 32 A, sisenemisepinget on lubatud kuni 10%. Koormuse \u00fchendamiseks v\u00f5ib olla 6 v\u00f5i 12 pesad.<\/p>\n<p><\/p>\n<h2>Oluline on luua terviklik juhtimiss\u00fcsteem<\/h2>\n<p><\/p>\n<p>Valik kabineti, ploki v\u00f5i mooduli vahel s\u00f5ltub sellest, millist koormust on vaja \u00fchendada. Suurtes andmekeskustes on vajalikud jaotuskabinette, kuid see ei v\u00e4listata t\u00e4iendavate moodulite v\u00f5i plokkide paigaldamist eraldi koormuse toitmiseks. <\/p>\n<p><\/p>\n<p>Keskmise suurusega serveriruumides osutub sageli piisavaks \u00fcks v\u00f5i kaks jaotamisplokki. Selle lahenduse eeliseks on see, et moodulite arvu saab suurendada, skaleerides toite s\u00fcsteemi koos andmekeskuse arenguga.<\/p>\n<p><\/p>\n<p>Erakilistes kappidest paigaldatakse tavaliselt jaotusseadmed, mida piisab v\u00e4ikese serveriruumi varustamiseks. \u00dchtse halduss\u00fcsteemi olemasolul v\u00f5imaldavad need ka energiatarbimise j\u00e4lgimist ja kontrollimist, kuid ei v\u00f5imalda d\u00fcnaamilist liinide \u00fcmberjaotamist ega kontaktidelementide ja releede kuuma vahetust.<\/p>\n<p><\/p>\n<p>Kaasaegsetes andmekeskustes v\u00f5ib samaaegselt leida nii kabinette, mooduleid kui ka jaotusseadmeid, mis on paigaldatud erinevatel aegadel ja erinevatel eesm\u00e4rkidel. Peamine on \u00fchendada kogu varustus energiatarnete haldamiseks \u00fchte j\u00e4lgimiss\u00fcsteemi. See v\u00f5imaldab j\u00e4lgida k\u00f5ikide elektrikute parameetrite k\u00f5rvalekaldeid ja kiiresti reageerida: vahetada seadmeid, suurendada v\u00f5imsust v\u00f5i suunata koormus teistele liinidele\/faasidele. Seda saab teha tarkvara kaudu, nagu Delta InfraSuite v\u00f5i analoogne toode.<\/p>\n<p class=\"for_users_only_msg\">Ainult registreeritud kasutajad saavad k\u00fcsitluses osaleda. <noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/auth\/login\/\">Logige sisse<\/a><\/noindex>, palun.<\/p>\n<h2 class=\"default-block__polling-title\">Kas teie v\u00f5rgus kasutatakse energiatarbimise halduss\u00fcsteeme?<\/h2>\n<ul class=\"content-list content-list_polling\">\n<li class=\"content-list__item content-list__item_polling\">\n<p>                    Kabinetid<\/p>\n<\/li>\n<li class=\"content-list__item content-list__item_polling\">\n<p>                    Moodulid<\/p>\n<\/li>\n<li class=\"content-list__item content-list__item_polling\">\n<p>                    Jaotusseadmed<\/p>\n<\/li>\n<li class=\"content-list__item content-list__item_polling\">\n<p>                    Ei<\/p>\n<\/li>\n<\/ul>\n<p>    H\u00e4\u00e4letas 7 kasutajat. 2 kasutajat j\u00e4id erapooletuks.<br \/>\n<br \/>Allikas: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/delta\/blog\/455976\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0446\u0435\u043d\u0442\u0440\u044b \u043e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u0445 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0432\u043d\u0438\u043c\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0430 \u043a \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043f\u0438\u0442\u0430\u043d\u0438\u044e. \u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043e\u0434\u043d\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u043e\u0442\u0441\u043b\u0435\u0436\u0438\u0432\u0430\u0442\u044c \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u0442\u044c \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. \u0421\u0434\u0435\u043b\u0430\u0442\u044c \u044d\u0442\u043e \u043c\u043e\u0436\u043d\u043e, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044f \u043a\u0430\u0431\u0438\u043d\u0435\u0442\u044b, \u043c\u043e\u0434\u0443\u043b\u0438 \u0438\u043b\u0438 \u0431\u043b\u043e\u043a\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u043f\u0438\u0442\u0430\u043d\u0438\u044f. \u041e \u0442\u043e\u043c, \u043a\u0430\u043a\u043e\u0439 \u0442\u0438\u043f \u044d\u043d\u0435\u0440\u0433\u043e\u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043b\u0443\u0447\u0448\u0435 \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0445 \u0441\u0438\u0442\u0443\u0430\u0446\u0438\u0439, \u043c\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u043c \u0432 \u043d\u0430\u0448\u0435\u043c \u043f\u043e\u0441\u0442\u0435 \u043d\u0430 \u043f\u0440\u0438\u043c\u0435\u0440\u0430\u0445 \u0440\u0435\u0448\u0435\u043d\u0438\u0439 Delta. \u042d\u043d\u0435\u0440\u0433\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u0435 \u0434\u0438\u043d\u0430\u043c\u0438\u0447\u043d\u043e \u0440\u0430\u0437\u0432\u0438\u0432\u0430\u044e\u0449\u0435\u0433\u043e\u0441\u044f \u0426\u041e\u0414 \u0447\u0430\u0441\u0442\u043e \u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442\u0441\u044f \u043d\u0435\u043f\u0440\u043e\u0441\u0442\u043e\u0439 \u0437\u0430\u0434\u0430\u0447\u0435\u0439. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":26514,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-35321","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\".\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"et_EE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u041a\u0430\u0431\u0438\u043d\u0435\u0442\u044b, \u043c\u043e\u0434\u0443\u043b\u0438 \u0438\u043b\u0438 \u0431\u043b\u043e\u043a\u0438 \u2013 \u0447\u0442\u043e \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043f\u0438\u0442\u0430\u043d\u0438\u0435\u043c \u0432 \u0426\u041e\u0414? | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\".\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:03:38+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:03:38+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Kabinetid, moodulid v\u00f5i jaotusseadmed \u2013 mida valida energiatarbimise haldamiseks andmekeskuses? | ProHoster","description":".","canonical_url":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"et_EE","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u041a\u0430\u0431\u0438\u043d\u0435\u0442\u044b, \u043c\u043e\u0434\u0443\u043b\u0438 \u0438\u043b\u0438 \u0431\u043b\u043e\u043a\u0438 \u2013 \u0447\u0442\u043e \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043f\u0438\u0442\u0430\u043d\u0438\u0435\u043c \u0432 \u0426\u041e\u0414? | ProHoster","og:description":".","og:url":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/kabinety-moduli-ili-bloki-chto-vybrat-dlya-upravleniya-elektropitaniem-v-tsod","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:03:38+00:00","article:modified_time":"2019-10-31T19:03:38+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"35321","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-21 22:47:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 02:06:23","updated":"2026-01-21 22:47:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts\/35321","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/comments?post=35321"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts\/35321\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/media\/26514"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/media?parent=35321"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/categories?post=35321"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/tags?post=35321"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}