{"id":38294,"date":"2019-10-31T22:22:48","date_gmt":"2019-10-31T19:22:48","guid":{"rendered":"https:\/\/prohoster.info\/blog\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\/"},"modified":"2019-10-31T22:22:48","modified_gmt":"2019-10-31T19:22:48","slug":"anboksing-stoechnogo-servera-cisco-ucs-c240-m5","status":"publish","type":"post","link":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","title":{"rendered":"Cisco UCS C240 M5 serveri unboximine","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>T\u00e4na tutvustame me uuendatud Cisco UCS C240 rack-serverit viienda p\u00f5lvkonna mudelina. <\/p>\n<p>Miks on just see Cisco server huvitav avamise puhul, arvestades, et see on juba viies p\u00f5lvkond? <\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri unboximine\" src=\"\/wp-content\/uploads\/2019\/09\/419d39ba895739a71b337f03445a9c32.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nEsiteks toetavad Cisco serverid n\u00fc\u00fcd uut Intel Scalable protsessorite teise p\u00f5lvkonna seeriat. Teiseks on n\u00fc\u00fcd v\u00f5imalik paigaldada Optane Memory mooduleid, et kasutada mitmeid NVMe salvestusseadmeid. <br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nT\u00f5statuvad \u00f5igustatud k\u00fcsimused: kas teised tootjad ei suuda sama? Mis on selles erilist, kuna see on lihtsalt x86 server? K\u00f5ike j\u00e4rjestikku. <\/p>\n<p>Lisaks iseseisva serveri funktsioonidele v\u00f5ib Cisco C240 M5 olla osa Cisco UCS arhitektuurist. Siin r\u00e4\u00e4gime FI-le \u00fchendamisest ja serverite t\u00e4iest haldamisest UCS Manageri vahendite abil, sealhulgas Auto Deploy. <\/p>\n<p>Nii et meil on ees \u201craudne\u201d Cisco server, selle viies p\u00f5lvkond, turul juba \u00fcle 10 aasta. <br \/>\nPraegu naaseme p\u00f5hiasjade juurde, meenutame, millistest komponentidest server koosneb ja mis teeb Cisco C240 M5 mitte lihtsalt kaasaegseks, vaid t\u00f5eliselt k\u00f5rgtehnoloogiliseks. <\/p>\n<p>Vaadakem, mis on komplektis. <\/p>\n<p><b>Kasti sisu<\/b>: server, KVM dongle, dokumendid, ketas, 2 toitekaablit, paigalduskomplekt. <\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri unboximine\" src=\"\/wp-content\/uploads\/2019\/09\/4e6b39ebc4a78f8b37b29ea2d76da14e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nEemaldame katte. Vajutame, nihkame ja k\u00f5ik. \u00dckski kruvi ei kao ja kruvitsi pole vaja. <br \/>\nSilma hakkavad kohe rohelised sildid. K\u00f5ik elemendid, mis toetavad kuuma vahetust, on varustatud nendega. N\u00e4iteks saab ventilaatoreid vahetada ilma kogu serveri v\u00e4lja l\u00fclitamiseta. <\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri unboximine\" src=\"\/wp-content\/uploads\/2019\/09\/cb2fcaf627f96dd947421f65e80c2638.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nSamuti n\u00e4eme massiivseid radiaatoreid, mille all peituvad uued Intel Scal 2 Gen protsessorid. Oluline on m\u00e4rkida, et 2U-serveris on kuni 56 tuuma ning ei esine probleeme jahutamisega. Samuti toetatakse rohkem m\u00e4lu, kuni 1TB iga protsessori kohta. M\u00e4lu toetatav sagedus on samuti t\u00f5usnud 2933 MHz. <\/p>\n<p>CPU k\u00f5rval n\u00e4eme 24 pesa m\u00e4lule \u2014 saab kasutada kuni 128 GB m\u00e4luklippe v\u00f5i Intel Optane m\u00e4lusid, mille maht on kuni 512 GB \u00fche pesa kohta.<\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri unboximine\" src=\"\/wp-content\/uploads\/2019\/09\/147f87e31e346dbb0f360c92dccde512.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIntel Optane avab meie ees uskumatud t\u00f6\u00f6tlemiskiirus. N\u00e4iteks saab seda kasutada superkiire kohaliku SSD-diskina.<\/p>\n<p>Praegu algab \u00fcha rohkem klientide p\u00e4ringuid lausega: \"Soovin rohkem kettasid, rohkem NVMe salvestusi \u00fches s\u00fcsteemis\". <\/p>\n<p>Eespool n\u00e4eme 8 2,5-tollist pesa salvestite jaoks. Samuti on saadaval tellimiseks platvormi variant standardsete 24 pesa ette.<\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri unboximine\" src=\"\/wp-content\/uploads\/2019\/09\/ddeca4947e941f1dadfe2a691b8729d8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nS\u00f5ltuvalt konfiguratsioonist saab esimesse pesasse paigaldada kuni 8 NMVe ketast U.2 formaadis. <\/p>\n<p>Platvorm C240 on \u00fcldiselt v\u00e4ga populaarne andmeanal\u00fc\u00fcsiga tegelevate klientide seas. Nende peamine soov on v\u00f5imalus omada salvestusseadmeid kohalikuks laadimiseks ja eelistatavalt hot pluggable.<\/p>\n<p>Sellele soovile vastas Cisco lahendus C240 M5, lisades serveri tagak\u00fcljele kaks ketaspesa kuumavahetuse toetamiseks.<\/p>\n<p>Need on paigutatud paremale laienduspesa kohal toiteplokkide suunas. Salvestusseadmed v\u00f5ivad olla mistahes: SAS, SATA, SSD, NVMe.<\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri unboximine\" src=\"\/wp-content\/uploads\/2019\/09\/33ef5ba06667b6e130ce724bd27cf857.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nK\u00f6ided on 1600W toiteplokid. Need on samuti Hot Pluggable ja t\u00e4histatud roheliste siltidega.<\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri unboximine\" src=\"\/wp-content\/uploads\/2019\/09\/46ab4548bc3d84d497f772f7c8eaa633.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nDiskialustusega t\u00f6\u00f6tamiseks saab p\u00fchendatud pesasse paigaldada RAID-kontrolleri LSI-lt, millel on 2 GB vahem\u00e4lu, v\u00f5i HBA-kaardi otse\u00fclekandeks.<\/p>\n<p>Seda l\u00e4henemist kasutatakse n\u00e4iteks Cisco HyperFlexi h\u00fcperkonvergeeritud lahenduse ehitamisel.<\/p>\n<p>On ka teistsugune klient, kellele kettad \u00fcldse ei sobi. Nad ei soovi paigaldada t\u00e4it RAID-kontrollerit h\u00fcperviisori alla, kuid hindavad 2U korpuse hoolduse kergust.<br \/>\nNende jaoks on Cisco-l ka lahendus.<\/p>\n<p>Tutvustan FlexFlash moodulit:<br \/>\nKaks SD-m\u00e4kaart maksimaalselt 128 GB, peegeldamise toetusega, h\u00fcperviisori nagu VMware ESXi installimiseks. Just seda varianti kasutame ITGLOBAL.COM-is oma platvormide \u00fclesehitamisel \u00fcle kogu maailma. <\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri unboximine\" src=\"\/wp-content\/uploads\/2019\/09\/d265c93e1e60428c69132b3cddb3a790.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nKliendid, kes vajavad rohkem ruumi operatsioonis\u00fcsteemi laadimiseks, saavad valida kahe \u00abSATA\u00bb SSD-diski moduli M.2 formaadis, iga\u00fche mahuga 240 v\u00f5i 960 GB. Vaikimisi on see tarkvaraline RAID. <\/p>\n<p>240 GB seadmete jaoks on saadaval Cisco Boot optimized M.2 RAID-kontrolleri valik \u2014 eraldi riistvaraline RAID-kontroller nende kahe SSD jaoks.<\/p>\n<p>K\u00f5ik see toetab k\u00f5iki operatsioonis\u00fcsteeme: nii VMware, Windows kui ka erinevaid Linuxi OS-e.<br \/>\nPCI-sisalduse arv on 6, mis on iseloomulik 2U platvormile. <\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri unboximine\" src=\"\/wp-content\/uploads\/2019\/09\/67f57214e9f99cbad0add05865ed83f8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nSees on piisavalt ruumi. Serveritesse on lihtne paigaldada kaks t\u00e4isfunktsionaalset graafikakiirendajat NVidialt, n\u00e4iteks TESLA M10 projektidesse, <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/et\/vps\/abuzoustojchivye-vps\/\"   title=\"virtuaalsed t\u00f6\u00f6laudade\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"1009\">virtuaalsed t\u00f6\u00f6laudade<\/a> v\u00f5i uusim versioon V100 32 GB jaoks tehisintellekti \u00fclesannete t\u00e4itmiseks. Just seda kasutame j\u00e4rgmises unboxing'is.<\/p>\n<p>Sadamate olukord on j\u00e4rgmine: <\/p>\n<ul>\n<li>Konsolipord;<\/li>\n<li>Gigabitne eraldatud haldussadam;<\/li>\n<li>Kaks USB 3.0 porti;<\/li>\n<li>Integreeritud kaheportiline Intel x550 10Gb BASE-T v\u00f5rkaart;<\/li>\n<li>Valikuline mLOM kaart, Cisco Vic 1387 kahepordiline adapter, mis toetab 40 Gbps.<\/li>\n<\/ul>\n<p>\nmLOM pesa v\u00f5imaldab paigaldada ainult Cisco VIC kaarte, mis on t\u00f5husad nii LAN- kui ka SAN-andmeside edastamiseks. Kui server on osa Cisco UCS tehases, v\u00f5imaldab see l\u00e4henemine LAN- ja SAN-v\u00f5rkude \u00fchendamist \u00fchtselt ilma eraldi fc adapteri kasutamiseta. <\/p>\n<p>Paigaldame Nvidia V100 graafikakaardi. Eemaldame teise riser'i, v\u00f5tame v\u00e4lja pistiku, sisestame kaardi PCI pesasse, sulgeme plastiku ja seej\u00e4rel pistiku. \u00dchendame t\u00e4iendava toite. Esmalt kaardile, seej\u00e4rel riser'ile. Asetame riseri tagasi oma kohtadele. K\u00f5ik l\u00e4heb kiiresti ja sujuvalt, ilma kruvikeerajate ja haamriteta.<\/p>\n<p>J\u00e4rgnevates materjalides tutvustame selle algse paigaldamise protsessi. <\/p>\n<p>Olemegi valmis vastama k\u00f5igile k\u00fcsimustele <noindex><a rel=\"nofollow\" href=\"https:\/\/itglobal.com\/ru-ru\/solutions\/tech-partners\/cisco\/servers-unified-computing-system-ucs\/\">siit<\/a><\/noindex> v\u00f5i kommentaarides.<br \/>\n<br \/>Allikas: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/itglobalcom\/blog\/467981\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435? \u0412\u043e-\u043f\u0435\u0440\u0432\u044b\u0445, \u0441\u0435\u0440\u0432\u0435\u0440\u044b Cisco \u0442\u0435\u043f\u0435\u0440\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u0432 Intel Scalable \u0432\u0442\u043e\u0440\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0412\u043e-\u0432\u0442\u043e\u0440\u044b\u0445, \u0442\u0435\u043f\u0435\u0440\u044c \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043c\u043e\u0434\u0443\u043b\u0438 Optane Memory \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u0430 NVMe-\u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":28746,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-38294","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435? \u0412\u043e-\u043f\u0435\u0440\u0432\u044b\u0445, \u0441\u0435\u0440\u0432\u0435\u0440\u044b Cisco \u0442\u0435\u043f\u0435\u0440\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u0432 Intel Scalable \u0432\u0442\u043e\u0440\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0412\u043e-\u0432\u0442\u043e\u0440\u044b\u0445, \u0442\u0435\u043f\u0435\u0440\u044c \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043c\u043e\u0434\u0443\u043b\u0438 Optane Memory \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u0430 NVMe-\u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"et_EE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435? \u0412\u043e-\u043f\u0435\u0440\u0432\u044b\u0445, \u0441\u0435\u0440\u0432\u0435\u0440\u044b Cisco \u0442\u0435\u043f\u0435\u0440\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u0432 Intel Scalable \u0432\u0442\u043e\u0440\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0412\u043e-\u0432\u0442\u043e\u0440\u044b\u0445, \u0442\u0435\u043f\u0435\u0440\u044c \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043c\u043e\u0434\u0443\u043b\u0438 Optane Memory \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u0430 NVMe-\u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Cisco UCS C240 M5 rack-serveri unboxing | ProHoster","description":"T\u00e4na on meil laual uus Cisco UCS C240 rack-server viiendas p\u00f5lvkonnas. Mis teeb selle Cisco serveri unboxing'u jaoks huvitavaks, arvestades, et see on juba viies p\u00f5lvkond? Esiteks, Cisco serverid toetavad n\u00fc\u00fcd viimase p\u00f5lvkonna Intel Scalable protsessoreid teises p\u00f5lvkonnas. Teiseks on n\u00fc\u00fcd v\u00f5imalik installida Optane Memory mooduleid, et kasutada mitmeid NVMe-m\u00e4lusid.","canonical_url":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"et_EE","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster","og:description":"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435? \u0412\u043e-\u043f\u0435\u0440\u0432\u044b\u0445, \u0441\u0435\u0440\u0432\u0435\u0440\u044b Cisco \u0442\u0435\u043f\u0435\u0440\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u0432 Intel Scalable \u0432\u0442\u043e\u0440\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0412\u043e-\u0432\u0442\u043e\u0440\u044b\u0445, \u0442\u0435\u043f\u0435\u0440\u044c \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043c\u043e\u0434\u0443\u043b\u0438 Optane Memory \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u0430 NVMe-\u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439.","og:url":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:22:48+00:00","article:modified_time":"2019-10-31T19:22:48+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"38294","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-02-09 13:06:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 01:12:21","updated":"2026-02-09 13:06:19"},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts\/38294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/comments?post=38294"}],"version-history":[{"count":1,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts\/38294\/revisions"}],"predecessor-version":[{"id":158206,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts\/38294\/revisions\/158206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/media\/28746"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/media?parent=38294"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/categories?post=38294"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/tags?post=38294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}