{"id":38294,"date":"2019-10-31T22:22:48","date_gmt":"2019-10-31T19:22:48","guid":{"rendered":"https:\/\/prohoster.info\/blog\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\/"},"modified":"2019-10-31T22:22:48","modified_gmt":"2019-10-31T19:22:48","slug":"anboksing-stoechnogo-servera-cisco-ucs-c240-m5","status":"publish","type":"post","link":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","title":{"rendered":"Cisco UCS C240 M5 serveri avamine","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>T\u00e4na on meie laual uus rack-server Cisco UCS C240 viiendast p\u00f5lvkonnast. <\/p>\n<p>Mis teeb just selle Cisco serveri huvitavaks, arvestades, et meil on juba selle viies p\u00f5lvkond? <\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri avamine\" src=\"\/wp-content\/uploads\/2019\/09\/419d39ba895739a71b337f03445a9c32.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nEsiteks, Cisco serverid toetavad n\u00fc\u00fcd uusimat Intel Scalable protsessorite teist p\u00f5lvkonda. Teiseks, n\u00fc\u00fcd on v\u00f5imalik paigaldada Optane m\u00e4lu mooduleid, et kasutada mitmeid NVMe-salvestusseadmeid. <br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nK\u00fcsimused tekivad: kas teiste tootjate serverid ei oska seda teha? Mis selles nii erilist on, kui see on lihtsalt x86 server? R\u00e4\u00e4gime sellest j\u00e4rjestikku. <\/p>\n<p>Lisaks eraldi serveri \u00fclesannetele v\u00f5ib Cisco C240 M5 olla osa Cisco UCS arhitektuurist. Siin r\u00e4\u00e4gime \u00fchendusest FI-ga ja serverite t\u00e4ielikust haldamisest UCS Manageri abil, sealhulgas Auto Deploy. <\/p>\n<p>Nii et meil on siin \"f\u00fc\u00fcsiline\" server Cisco, selle viies p\u00f5lvkond, turul \u00fcle 10 aasta. <br \/>\nPraegu tagasime p\u00f5hialuste juurde, meenutame, millistest komponentidest server koosneb, ja mis teeb Cisco C240 M5 mitte lihtsalt kaasaegseks, vaid t\u00f5eliselt uuenduslikuks. <\/p>\n<p>Vaadakem, mis komplekti kuulub. <\/p>\n<p><b>Pakendi sisu<\/b>: server, KVM-dongel, dokumendid, ketas, 2 toitekaablit, paigalduskomplekt. <\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri avamine\" src=\"\/wp-content\/uploads\/2019\/09\/4e6b39ebc4a78f8b37b29ea2d76da14e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nEemaldame kaane. Vajutame, liigutame ja k\u00f5ik. Ei mingit kruvikeerajat ega kadunud mutreid. <br \/>\nSilma hakkavad kohe rohelised sildid. K\u00f5ik elemente, millel on kuumavahetuse tugi, omavad neid. N\u00e4iteks saab ventilaatoreid vahetada ilma kogu serveri v\u00e4lja l\u00fclitamata. <\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri avamine\" src=\"\/wp-content\/uploads\/2019\/09\/cb2fcaf627f96dd947421f65e80c2638.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nSamuti n\u00e4eme massiivseid radiaatoreid, mille all peidavad end uued Intel Scal 2 Gen protsessorid. T\u00e4helepanuv\u00e4\u00e4rne on, et see on kuni 56 tuuma 2U-serveris ilma k\u00fclmutusprobleemideta. Samuti toetatakse rohkem m\u00e4lu, kuni 1TB protsessori kohta. Toetatud m\u00e4lufrekvents on t\u00f5usnud kuni 2933 MHz. <\/p>\n<p>CPU k\u00f5rval n\u00e4eme 24 RAM-i pesa \u2014 saab kasutada kuni 128 GB plaate v\u00f5i Intel Optane m\u00e4lu kuni 512 GB pesa kohta.<\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri avamine\" src=\"\/wp-content\/uploads\/2019\/09\/147f87e31e346dbb0f360c92dccde512.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIntel Optane avab meie ees \u00e4\u00e4rmiselt kiire t\u00f6\u00f6tlemise kiirus. N\u00e4iteks saab seda kasutada superkiire kohaliku SSD-diskina.<\/p>\n<p>Praegu algavad \u00fcha rohkem kliendik\u00fcsitlustest s\u00f5nadega: \"Soovin rohkem kettaid, rohkem NVMe salvestusseadmeid \u00fches s\u00fcsteemis.\" <\/p>\n<p>Eesmisel poolel n\u00e4eme 8 2.5-tollist pesa salvestusseadmete jaoks. Samuti on saadaval tellimisel variant platvormile standardsete 24 pesa korral esipaneelil.<\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri avamine\" src=\"\/wp-content\/uploads\/2019\/09\/ddeca4947e941f1dadfe2a691b8729d8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nS\u00f5ltuvalt muudatusest saab esimestesse pesadesse paigaldada kuni 8 NMVe ketast form factor U.2. <\/p>\n<p>C240 platvorm on \u00fcldiselt v\u00e4ga populaarne suurte andmete haldamisega tegelevate klientide seas. Nende peamine n\u00f5ue on omada kohalikke kettaid ja eelistatult hot pluggable funktsiooni.<\/p>\n<p>Vastuseks sellele n\u00f5udmisele lisas Cisco C240 M5-le tagasi serverisse kaks pesad hot swap toetavate ketaste jaoks.<\/p>\n<p>Need asuvad toiteplokkide laienduspesa paremal k\u00fcljel. Kettad v\u00f5ivad olla \u00fcksk\u00f5ik millised: SAS, SATA, SSD, NVMe.<\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri avamine\" src=\"\/wp-content\/uploads\/2019\/09\/33ef5ba06667b6e130ce724bd27cf857.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nKohal on 1600W toiteplokid. Need on samuti hot pluggable ja varustatud roheliste siltidega.<\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri avamine\" src=\"\/wp-content\/uploads\/2019\/09\/46ab4548bc3d84d497f772f7c8eaa633.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nDiskis\u00fcsteemi t\u00f6\u00f6tluseks on eraldi pesasse v\u00f5imalik installida LSI RAID-kontroller, millel on 2GB vahem\u00e4lu, v\u00f5i HBA-kaart otse\u00fclekande jaoks.<\/p>\n<p>N\u00e4iteks kasutatakse sellist l\u00e4henemist Cisco HyperFlex h\u00fcperkonvergeeritud lahenduste ehitamisel.<\/p>\n<p>On olemas veel \u00fcks t\u00fc\u00fcpi kliente, kellele kettad \u00fcldse ei ole vajalikud. Nad ei soovi installida kogu RAID-kontrollerit h\u00fcpervisori alla, kuid neile meeldib 2U korpus selle hoolduse mugavuse t\u00f5ttu.<br \/>\nNende jaoks on Cisco-l samuti lahendus.<\/p>\n<p>Esitlen FlexFlash moduli:<br \/>\nKaks SD-kaarti, mahuga kuni 128GB, peegeldamise toetusega, h\u00fcpervisori, n\u00e4iteks VMware ESXi, installimiseks. Just seda varianti kasutame ITGLOBAL.COM-il oma teenuste loomisel \u00fcle kogu maailma. <\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri avamine\" src=\"\/wp-content\/uploads\/2019\/09\/d265c93e1e60428c69132b3cddb3a790.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nNeed kliendid, kes vajavad rohkem ruumi OS-i laadimiseks, saavad valida moduli, kus on kaks M.2 formaadis \"SATA\" SSD-d, mille mahud on 240 v\u00f5i 960 GB iga\u00fche kohta. Vaikimisi on see tarkvara RAID. <\/p>\n<p>240GB ketaste jaoks on olemas valik kasutada Cisco Boot optimized M.2 RAID-kontrollerit - eraldi riistvara RAID-kontroller nende kahe SSD ketta jaoks.<\/p>\n<p>K\u00f5ike seda toetavad k\u00f5ik operatsioonis\u00fcsteemid: nii VMware, Windows kui ka erinevad Linuxi OS-id.<br \/>\nPCI pesade arv on 6, mis on iseloomulik 2U platvormidele. <\/p>\n<p><img decoding=\"async\" alt=\"Cisco UCS C240 M5 serveri avamine\" src=\"\/wp-content\/uploads\/2019\/09\/67f57214e9f99cbad0add05865ed83f8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nSees on piisavalt ruumi. Serveritesse on lihtne paigaldada kaks t\u00e4ie\u00f5iguslikku graafikakiirendajat NVidia-lt, n\u00e4iteks TESLA M10 rakendustes. <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/et\/vps\/abuzoustojchivye-vps\/\"   title=\"virtuaalsetele t\u00f6\u00f6lauale\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"1009\">virtuaalsetele t\u00f6\u00f6lauale<\/a> v\u00f5i uusim V100 32GB v\u00e4ljaanne tehisintellekti \u00fclesannete jaoks. Seda kasutame j\u00e4rgmises unboxing'is.<\/p>\n<p>Portide osas on olukord j\u00e4rgmine: <\/p>\n<ul>\n<li>Konsolipordid;<\/li>\n<li>Gigabiti p\u00fchendatud haldusport;<\/li>\n<li>Kaks USB 3.0 porti;<\/li>\n<li>Integreeritud 2-portine Intel x550 10Gb BASE-T v\u00f5rkaart;<\/li>\n<li>Valikuline mLOM kaart, Cisco Vic 1387 kaheastmeline adapter 40Gb jaoks.<\/li>\n<\/ul>\n<p>\nmLOM sloti saab paigaldada ainult Cisco VIC kaarte, mis on efektiivsed nii LAN-i kui ka SAN-i liikluse edastamiseks. Cisco UCS tehases serverit kasutades v\u00f5imaldab selline l\u00e4henemine luua \u00fchtse \u00fchenduse LAN-i ja SAN-i v\u00f5rkudega ilma, et oleks vaja eraldi fc-adapterit. <\/p>\n<p>Paigaldame Nvidia V100 graafikakaardi. Eemaldame teise raiseri, v\u00f5tame kaitse \u00e4ra, paneme kaardi PCI slotti, sulgeme plasti ja seej\u00e4rel kaitse. \u00dchendame toiteseadmestiku. Esmalt kaardile, seej\u00e4rel raiserile. Paneme raiseri oma kohale tagasi. \u00dcldiselt toimub k\u00f5ik ilma kruvikeerajate ja haamrite kasutamiseta. Kiire ja t\u00e4pne.<\/p>\n<p>\u00dches j\u00e4rgmistest materjalidest n\u00e4itame selle esmast installimist. <\/p>\n<p>Samuti oleme valmis vastama k\u00f5ikidele k\u00fcsimustele <noindex><a rel=\"nofollow\" href=\"https:\/\/itglobal.com\/ru-ru\/solutions\/tech-partners\/cisco\/servers-unified-computing-system-ucs\/\">siin<\/a><\/noindex> v\u00f5i kommentaarides.<br \/>\n<br \/>Allikas: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/itglobalcom\/blog\/467981\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435? \u0412\u043e-\u043f\u0435\u0440\u0432\u044b\u0445, \u0441\u0435\u0440\u0432\u0435\u0440\u044b Cisco \u0442\u0435\u043f\u0435\u0440\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u0432 Intel Scalable \u0432\u0442\u043e\u0440\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0412\u043e-\u0432\u0442\u043e\u0440\u044b\u0445, \u0442\u0435\u043f\u0435\u0440\u044c \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043c\u043e\u0434\u0443\u043b\u0438 Optane Memory \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u0430 NVMe-\u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":28746,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-38294","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"et_EE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Cisco UCS C240 M5 rack-serveri unboxing | ProHoster","description":"T\u00e4na on meie laual uus Cisco UCS C240 rack-server viiendast p\u00f5lvkonnast. Miks on just see Cisco server unboximiseks huvitav, arvestades, et see on juba tema viies p\u00f5lvkond?","canonical_url":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"et_EE","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster","og:description":"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?","og:url":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:22:48+00:00","article:modified_time":"2019-10-31T19:22:48+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"38294","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-02-09 13:06:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 01:12:21","updated":"2026-02-09 13:06:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts\/38294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/comments?post=38294"}],"version-history":[{"count":1,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts\/38294\/revisions"}],"predecessor-version":[{"id":158206,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts\/38294\/revisions\/158206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/media\/28746"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/media?parent=38294"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/categories?post=38294"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/tags?post=38294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}