{"id":79649,"date":"2020-04-29T07:42:06","date_gmt":"2020-04-29T05:42:06","guid":{"rendered":"https:\/\/prohoster.info\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br"},"modified":"2020-04-29T07:42:06","modified_gmt":"2020-04-29T05:42:06","slug":"extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","status":"publish","type":"post","link":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","title":{"rendered":"\u00abExtreme Extended Edge\u00bb, v\u00f5i IEEE 802.1BR standardil p\u00f5hinev l\u00fclitamine","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Lahendus \u00abExtreme Extended Edge\u00bb (tuntud ka kui Virtual Port Extender \u2013 VPEX) on uus tehnoloogia, mille toetust esmakordselt tutvustati EXOS operatsioonis\u00fcsteemis alates versioonist 22.5. Lahendus ise p\u00f5hineb IEEE 802.1BR (Bridge Port Extension) standardil, ning EXOS 22.5 versioonis lisati tugi uuele ExtremeSwitching V400 riistvaraseeriale.<\/p>\n<p><img decoding=\"async\" alt=\"\u00abExtreme Extended Edge\u00bb, v\u00f5i IEEE 802.1BR standardil p\u00f5hinev l\u00fclitamine\" src=\"\/wp-content\/uploads\/2020\/04\/ea282e49e9957cdd295691a0d945a049.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\n\u00abVPEX Bridge\u00bb on virtuaalne l\u00fcliti, mis koosneb sellistest komponentidest nagu \u2013 Controlling Bridge (CB) ja Bridge Port Extender (BPE). T\u00f5rke kindluse tagamiseks on v\u00f5imalik \u00fchendada kaks CB sama virtuaalse l\u00fcliti raames MLAG tehnoloogia abil. Sellise virtuaalse l\u00fcliti disain meenutab klassikalist \u0161assii l\u00fclitit v\u00f5i l\u00fclitite seeriat. Kui \u00abControl Plane\u00bb loogika on enam-v\u00e4hem \u00f5igustatud, siis \u00abData Plane\u00bb t\u00f6\u00f6 erineb m\u00e4rkimisv\u00e4\u00e4rselt. IEEE 802.1br on m\u00f5eldud kaugportide \u00fchendamiseks lokaalsete MAC (Media Access Control) teenustega, isolatsiooniga kaugportide liiklusest.<\/p>\n<h4><b>Controlling Bridge<\/b><\/h4>\n<p><\/p>\n<ul>\n<li> \u00dcksainsad juhtimispunkt<\/li>\n<li> Kogu konfigureerimine toimub CB-l lokaalselt<\/li>\n<li> VPEX-i toetust tuleb aktiveerida, t\u00f6\u00f6re\u017eiimi muutmiseks on vajalik taask\u00e4ivitamine<\/li>\n<li> CB on alati pesa nr 1<\/li>\n<li> Praeguses versioonis toetab CB samaaegset \u00fchendust kuni 48 BPE-ga<\/li>\n<li> CB re\u017eiimi toetatakse teatud riistvaraplatvormidel (praegu on need X670G2 ja X690, teisi platvorme lisatakse nende turule toomisega)<\/li>\n<li> EXOS litsentsid kehtivad ainult CB-le<\/li>\n<li> VPEX ei vaja t\u00e4iendavaid litsentse<\/li>\n<li> Vastutab t\u00e4ielikult andmesalvutuse ja liikluse filtreerimise eest<\/li>\n<li> Sisaldab virtuaalset esitlemist igast \u00abextended\u00bb portist<\/li>\n<\/ul>\n<p><\/p>\n<h4><b>Bridge Port Extender<\/b><\/h4>\n<p><\/p>\n<ul>\n<li> BPE seadmeid hallatakse nagu \u0161assii l\u00fclitite \u00fchendusi<\/li>\n<li> BPE pesade nummerdamine ulatub 100 kuni 162<\/li>\n<\/ul>\n<p><\/p>\n<pre><code class=\"plaintext\">Slot-1 VPEX X690-48x-2q-4c.3 # show slot\nPesad    T\u00fc\u00fcp                 Konfigureeritud           Oleku       Portide arv  Lipud\n-------------------------------------------------------------------------------\nSlot-1   X690-48x-2q-4c       X690-48x-2q-4c       T\u00f6\u00f6tab   72   M\nSlot-100 V400-48t-10GE4       V400-48t-10GE4       T\u00f6\u00f6tab   52   M\nSlot-101 V400-48t-10GE4       V400-48t-10GE4       T\u00f6\u00f6tab   52   M\nSlot-102 V400-48t-10GE4       V400-48t-10GE4       T\u00f6\u00f6tab   52   M\nSlot-103 V400-48t-10GE4       V400-48t-10GE4       T\u00f6\u00f6tab   52   M\n<\/code><\/pre>\n<p><\/p>\n<ul>\n<li> BPE-le ei ole vaja konsooli ega Out-of-Band IP \u00fchendust<\/li>\n<li> Kogu konfigureerimine, j\u00e4lgimine, t\u00f5rkeotsing ja diagnostika toimub CB liidese kaudu<\/li>\n<\/ul>\n<p><\/p>\n<pre><code class=\"plaintext\">Slot-1 VPEX X670G2-48x-4q.8 # config vlan v100 add port 100:1,100:3\n*Slot-1 VPEX X670G2-48x-4q.9 # show port 100:1-3 statistics no-refresh\nPort   Link      Tx Pkt     Tx Byte     Rx Pkt     Rx Byte  Rx Pkt   Tx Pkt\n       State      Count       Count      Count       Count   Mcast    Mcast\n====== ===== ========== =========== ========== =========== ======= ========\n100:1  A     2126523437 &gt;9999999999          0           0       0    14383\n100:2  R              0           0          0           0       0        0\n100:3  A          21824     4759804 2126738453 &gt;9999999999       0    14383\n====== ===== ========== =========== ========== =========== ======= ========\n<\/code><\/pre>\n<p><\/p>\n<ul>\n<li> BPE ei teosta kohalikku kommuteerimist. Selle tulemusena tunneliseeritakse kogu liiklus CB-le ja kui on vajalik, siis suunatakse see tagasi sama BPE riiuli naaberporti. (BPE v\u00f5tab paketi, lisab E-TAG p\u00e4ise ja saadab selle upstream porti)<\/li>\n<\/ul>\n<p>\nBPE t\u00f6\u00f6ks on esitatud uus riistvaraplatvorm ExtremeSwitching V400. See sisaldab 24\/48 10\/100\/1000 Base-T sadamate laiendusi koos PoE toe v\u00f5i ilma. 24 portiga mudelites on kaks 10G porti, 48-porti mudelites on neli 10G porti.<\/p>\n<p><img decoding=\"async\" alt=\"\u00abExtreme Extended Edge\u00bb, v\u00f5i IEEE 802.1BR standardil p\u00f5hinev l\u00fclitamine\" src=\"\/wp-content\/uploads\/2020\/04\/9575a2617f71bd74de9cc71a538d8a65.png\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<h4><b>T\u00f6\u00f6 omadused<\/b><\/h4>\n<p>\nToetatakse topoloogiaid, kus on \u00fcks v\u00f5i kaks SV-d ja kuni neli kaskaadil \u00fchendatud VRE-d. Kaskadiseeritavad portid saavad \u00fchineda LAG-iga (kuni 4 porti V400-48t\/p mudelite jaoks). L\u00f5ppjaamad saavad \u00fchenduda erinevate BPE riiulitega LAG-i kaudu.<\/p>\n<p><img decoding=\"async\" alt=\"\u00abExtreme Extended Edge\u00bb, v\u00f5i IEEE 802.1BR standardil p\u00f5hinev l\u00fclitamine\" src=\"\/wp-content\/uploads\/2020\/04\/0fa7476e2c1edc2a1d26705f7db3d456.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nBPE avastamine ja t\u00f6\u00f6 p\u00f5hinevad sellistel protokollidel nagu:<\/p>\n<ul>\n<li> LLDP \u2013 esmane tuvastamine ja \u00fchendatud seadme t\u00fc\u00fcbi ning omaduste m\u00e4\u00e4ramine<\/li>\n<li> ECP \u2013 \u201eEdge Control Protocol\u201d PE-CSP transport<\/li>\n<li> PE-CSP \u2013 \u201ePort Extender Control and Status Protocol\u201d BPE konfiguratsiooni kontroll Controlling Bridge'i kaudu<\/li>\n<li> LACP \u2013 LAGi seadistamine \u00abcascade\u00bb &lt;&#8212;&gt; \u00abupstream\u00bb portide vahel<\/li>\n<\/ul>\n<p>\nKui kasutatakse kahetasemelist projekti kahe SV ja MLAG-iga, siis \u00fche CB taask\u00e4ivitamisel j\u00e4tkab BPE liikluse saatmist \u00fclej\u00e4\u00e4nud Controlling Bridge'i kaudu. Kui ainus CB taask\u00e4ivitub, l\u00fclitab BPE oma \u201epikendatud\u201d portid halduslikult v\u00e4lja. <br \/>\nKaks SV-d kaskaadi topoloogiate lihtsustamiseks on lisatud v\u00f5imalus konfigureerida MLAG porte m\u00f5lema peer'i poolt \u00fche SV-st. Re\u017eiim nimetatakse \u201emlag orchestration\u201d, mille k\u00e4igus peer'id s\u00fcnkroneerivad osa konfiguratsioonist, mis on seotud MLAG portide seadistustega. Seadistamine meenutab kasutajate \u201evirtual-routerite\u201d seadistamist.<\/p>\n<pre><code class=\"plaintext\">Slot-1 VPEX X670G2-48x-4q.11 # start orchestration mlag \"bottom\"\n(orchestration bottom) Slot-1 VPEX X670G2-48x-4q.12 # exit\nSlot-1 VPEX X670G2-48x-4q.13 #\n<\/code><\/pre>\n<p>\nFunktsioon \"Controlling Bridge\" on saadaval p\u00e4rast tasuta EXOS mooduli installimist, millel on laiendus .xmod. Samuti sisaldab see sama moodul v\u00e4rskenduste pilte BPE jaoks. Kui CB ja BPE \u00fcksteist tuvastavad, kontrollib CB BPE-le installitud firmware'i versiooni ja vajadusel uuendab selle automaatselt.<\/p>\n<p>\u00dclaltoodud funktsioonid v\u00f5imaldavad maksimaalselt lihtsalt ja kiiresti vahetada BPE sloti vajadusel. Kuna BPE slotid ei tallenud konfiguratsiooni ja ei olnud s\u00fcsteemiga seotud, tuvastatakse BPE p\u00e4rast seadme vahetamist ja toite sissel\u00fclitamist CB poolt ning rakendatakse juba olemasolev konfigureerimine; samuti uuendatakse vajadusel firmware'i.<\/p>\n<p>See lahendus sobib h\u00e4sti v\u00f5rkudele, millel on domineeriv liiklussuun p\u00f5hja\/l\u00f5una, nagu \u00fclikoolilinnakud, ettev\u00f5tete v\u00f5rgud logistika ja hariduse valdkonnas, \u00e4ri- ja muudes keskustes. Kordame, et \"Extreme Extended Edge\" lahenduse p\u00f5hjal loodud v\u00f5rkude eelised on:<\/p>\n<ul>\n<li> Traditsioonilise v\u00f5rguarhitektuuri tasemete arvu v\u00e4hendamine konfiguratsiooni ja haldamise aspektist<\/li>\n<li> Skaleerimise ja juurutamise lihtsus<\/li>\n<li> Ei ole vajalik eraldi konsooli v\u00f5i OOV Mgmt \u00fchendusi BPE slottidega <\/li>\n<li> Litsentsimise v\u00e4henemine (vajadusel rakendatakse ainult CB-l)<\/li>\n<li> \u00dcksik konfigureerimise, j\u00e4lgimise ja t\u00f5rkeotsingu punkti olemasolu<\/li>\n<li> Kuvamine NMS-is kui \u00fcks l\u00fcliti<\/li>\n<li> Ei ole vajalik t\u00e4iendav koolitus ega t\u00f6\u00f6tajate arvu suurendamine<\/li>\n<\/ul>\n<p>Allikas: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/extremenetworks\/blog\/420369\/\">habr.com<\/a> <\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5. \u0421\u0430\u043c\u043e \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043e \u043d\u0430 \u0431\u0430\u0437\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR (Bridge Port Extension), \u0438 \u0432 \u0440\u0430\u043c\u043a\u0430\u0445 \u0440\u0435\u043b\u0438\u0437\u0430 EXOS 22.5 \u0431\u044b\u043b\u0430 \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d\u0430 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043d\u043e\u0432\u043e\u0439 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u044b\u0439 \u043b\u0438\u043d\u0435\u0439\u043a\u0438 ExtremeSwitching V400 \u00abVPEX Bridge\u00bb \u044d\u0442\u043e [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":79650,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-79649","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"et_EE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u00abExtreme Extended Edge\u00bb, \u0438\u043b\u0438 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u044f \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-04-29T05:42:06+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-04-29T05:42:06+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47\"Extreme Extended Edge\", v\u00f5i l\u00fclitamine vastavalt IEEE 802.1BR standardile | ProHoster","description":"Lahendus \"Extreme Extended Edge\" (tuntud ka kui Virtual Port Extender \u2013 VPEX) on uus tehnoloogia, mille toetust esmakordselt tutvustatakse EXOS-i operatsioonis\u00fcsteemis alates versioonist 22.5.","canonical_url":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"et_EE","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u00abExtreme Extended Edge\u00bb, \u0438\u043b\u0438 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u044f \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR | ProHoster","og:description":"\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5.","og:url":"https:\/\/prohoster.info\/et\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-04-29T05:42:06+00:00","article:modified_time":"2020-04-29T05:42:06+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"79649","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 16:34:38","updated":"2022-10-05 23:27:37","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts\/79649","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/comments?post=79649"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/posts\/79649\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/media\/79650"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/media?parent=79649"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/categories?post=79649"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/et\/wp-json\/wp\/v2\/tags?post=79649"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}