{"id":34884,"date":"2019-10-31T22:01:01","date_gmt":"2019-10-31T19:01:01","guid":{"rendered":"https:\/\/prohoster.info\/blog\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\/"},"modified":"2019-10-31T22:01:01","modified_gmt":"2019-10-31T19:01:01","slug":"upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","status":"publish","type":"post","link":"https:\/\/prohoster.info\/fr\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","title":{"rendered":"Mise \u00e0 niveau du syst\u00e8me de stockage d'un ancien serveur avec un bus PCIe 1.0 \u2014 2.0","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Mise \u00e0 niveau du syst\u00e8me de stockage d&#039;un ancien serveur avec un bus PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/68025340a72b1acac62371764f328712.jpg\" style=\"display:block;margin: 0 auto;\" \/><b class=\"spoiler_title\">Pourquoi le sujet de cet article est-il la mise \u00e0 niveau du syst\u00e8me de stockage ?<\/b>Il est clair que, dans la plupart des cas, il faut d'abord :<\/p>\n<ol>\n<li>Augmenter la m\u00e9moire vive. C'est une d\u00e9marche tellement \u00e9vidente que je n'ai m\u00eame pas jug\u00e9 n\u00e9cessaire d'en parler dans l'article principal.<\/li>\n<li>Installer des processeurs suppl\u00e9mentaires ou remplacer les deux processeurs par des versions les plus performantes compatibles avec les sockets du serveur.<\/li>\n<\/ol>\n<p>\nPour les anciens serveurs, il est g\u00e9n\u00e9ralement possible de trouver de la m\u00e9moire et des processeurs \u00e0 des prix tr\u00e8s bas.<\/p>\n<p>\u00c0 un certain moment, chaque propri\u00e9taire de serveur se retrouve confront\u00e9 \u00e0 la question : mise \u00e0 niveau ou nouveau serveur.<\/p>\n<p>\u00c9tant donn\u00e9 que le prix d'un nouveau serveur peut atteindre des millions de roubles, beaucoup choisissent la voie de la mise \u00e0 niveau.<\/p>\n<p>Pour une mise \u00e0 niveau r\u00e9ussie, il est tr\u00e8s important d'utiliser des compromis pour obtenir un gain de performance significatif pour un co\u00fbt mod\u00e9r\u00e9 (par rapport \u00e0 celui d'un nouveau serveur).<\/p>\n<p>Cet article pr\u00e9sente une liste de SSD PCI-E 2.0 x8 pour serveurs qui ont \u00e9norm\u00e9ment baiss\u00e9 de prix, ainsi que des contr\u00f4leurs RAID prenant en charge la mise en cache SSD et un SSD SATA III test\u00e9 sur une interface SATA II.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nLe moyen le plus \u00e9vident de mettre \u00e0 niveau le syst\u00e8me de stockage est de passer de HDD \u00e0 SSD. C'est vrai tant pour les ordinateurs portables que pour les serveurs. Dans le cas des serveurs, la seule diff\u00e9rence est que les SSD peuvent facilement \u00eatre configur\u00e9s en RAID.<\/p>\n<p>Il y a cependant des d\u00e9tails \u00e0 prendre en compte, notamment le fait qu'il se peut qu'il n'y ait pas de ports SATA III sur un ancien serveur, et dans ce cas, il faudra remplacer ou ajouter un contr\u00f4leur appropri\u00e9.<\/p>\n<p>Il existe bien s\u00fbr des m\u00e9thodes interm\u00e9diaires.<\/p>\n<h2>Mise en cache sur SSD.<\/h2>\n<p>\nDans l'ensemble, cette m\u00e9thode convient bien aux bases de donn\u00e9es, \u00e0 1C et \u00e0 tout acc\u00e8s al\u00e9atoire. La vitesse s'acc\u00e9l\u00e8re r\u00e9ellement. Pour de tr\u00e8s gros fichiers, comme la vid\u00e9osurveillance, cette m\u00e9thode est inutile.<\/p>\n<h3>Contr\u00f4leurs RAID LSI (IBM, DELL, CISCO, Fujitsu)<\/h3>\n<p>\n\u00c0 partir de la s\u00e9rie 92xx, LSI dispose de la technologie CacheCade 2.0, qui permet d'utiliser presque n'importe quel SSD SATA comme cache pour le tableau RAID, tant en lecture qu'en \u00e9criture. Il est m\u00eame possible de cr\u00e9er un miroir \u00e0 partir de SSD de cache.<\/p>\n<p>Avec les contr\u00f4leurs sous marque, c'est plus compliqu\u00e9. Cela concerne particuli\u00e8rement IBM. Les cl\u00e9s et SSD pour CacheCade devront \u00eatre achet\u00e9s chez IBM \u00e0 des prix exorbitants, il est donc plus simple de changer le contr\u00f4leur pour un LSI et d'acheter une cl\u00e9 mat\u00e9rielle \u00e0 bon march\u00e9. Les cl\u00e9s logicielles sont beaucoup plus ch\u00e8res que les cl\u00e9s mat\u00e9rielles.<\/p>\n<h3>Contr\u00f4leurs RAID Adaptec<\/h3>\n<p>\nLes contr\u00f4leurs Adaptec disposent de la technologie MaxCache, qui permet \u00e9galement d'utiliser des SSD comme cache. Nous nous int\u00e9ressons aux versions des contr\u00f4leurs qui se terminent par la lettre Q.<\/p>\n<p>Les contr\u00f4leurs Q peuvent utiliser presque n'importe quel SSD, et pas seulement ceux fournis par Adaptec.<\/p>\n<ul>\n<li>\u00c0 partir de la version 5xxx, tous les contr\u00f4leurs prennent en charge le raid hybride. L'id\u00e9e de cette technologie est que la lecture s'effectue toujours \u00e0 partir du SSD lorsqu'il existe un miroir d'un des disques contenant un SSD.<\/li>\n<li>5xxxQ, par exemple 5805ZQ. Ces contr\u00f4leurs prennent en charge MaxCache 1.0. Seulement pour le cache de lecture.<\/li>\n<li>6xxQ, par exemple 6805Q. MaxCache 2.0. Mise en cache de lecture et d'\u00e9criture.<\/li>\n<li>7xxQ, par exemple 7805Q. MaxCache 3.0. Mise en cache de lecture et d'\u00e9criture.<\/li>\n<li>8xxQ n'a presque aucun sens d'utilisation pour les mises \u00e0 niveau en raison des prix \u00e9lev\u00e9s.<\/li>\n<\/ul>\n<p>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/pc-administrator\/blog\/319214\/\">Article sur le cache sur SSD sur Habr (contr\u00f4leurs et syst\u00e8mes d'exploitation).<\/a><\/noindex><\/p>\n<h3>Technologies logicielles de mise en cache sur SSD<\/h3>\n<p>\nJe ne vais pas aborder ces technologies. Pratiquement tous les syst\u00e8mes d'exploitation les prennent en charge actuellement. Je me souviens qu'avec btrfs, il redirige automatiquement les requ\u00eates de lecture vers le p\u00e9riph\u00e9rique avec la plus courte file d'attente \u2014 le SSD.<\/p>\n<h2>SSD SATA III sur une interface SATA II<\/h2>\n<p>\n\u00c9tant donn\u00e9 qu'il n'y a pas toujours la possibilit\u00e9 ou les fonds pour un nouveau contr\u00f4leur, la question se pose de savoir \u00e0 quel point les SSD SATA III fonctionnent bien sur une interface obsol\u00e8te SATA II.<\/p>\n<p>R\u00e9aliser un petit test. Notre sujet d'essai sera un SSD SATA III Intel S3710 de 400 Go.<\/p>\n<p>Lecture al\u00e9atoire, iops<br \/>\nLatence moyenne de lecture, mS<br \/>\n\u00c9criture al\u00e9atoire, iops<br \/>\nLatence moyenne d'\u00e9criture, mS<br \/>\nLecture lin\u00e9aire, MB\/s<br \/>\n\u00c9criture lin\u00e9aire, MB\/s<\/p>\n<p>SATA II<br \/>\n21241<br \/>\n2<br \/>\n13580<br \/>\n4<br \/>\n282<br \/>\n235<\/p>\n<p>SATA III<br \/>\n68073<br \/>\n0.468<br \/>\n61392<br \/>\n0.52<br \/>\n514<br \/>\n462<\/p>\n<p>\n<b class=\"spoiler_title\">Commandes utilis\u00e9es pour tester la vitesse<\/b><\/p>\n<pre><code class=\"bash\">fio --name LinRead --eta-newline=5s --filename=\/dev\/sda --rw=read --size=500m --io_size=10g --blocksize=1024k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=1 --runtime=60 --group_reporting \nfio --name LinWrite --eta-newline=5s --filename=\/dev\/sda --rw=write --size=500m --io_size=10g --blocksize=1024k --ioengine=libaio --fsync=10000 --iodepth=32 --direct=1 --numjobs=1 --runtime=60 --group_reporting\n\nfio --name RandRead --eta-newline=5s --filename=\/dev\/sda --rw=randread --size=500m --io_size=10g --blocksize=4k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=4 --runtime=60 --group_reporting\n\nfio --name RandWrite --eta-newline=5s --filename=\/dev\/sda --rw=randwrite --size=500m --io_size=10g --blocksize=4k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=4 --runtime=60 --group_reporting\n<\/code><\/pre>\n<p>Comme on peut le voir, il y a une diff\u00e9rence significative en termes de vitesse lin\u00e9aire, d'IOPS et de latences, donc il est judicieux d'utiliser uniquement l'interface SATA III, et si elle n'est pas disponible, de mettre un contr\u00f4leur.<\/p>\n<p>Pour \u00eatre juste, je dirais que selon <noindex><a rel=\"nofollow\" href=\"http:\/\/www.thg.ru\/storage\/ustanovka_ssd_v_sistemu_s_sata_3_gbits_test\/ustanovka_ssd_v_sistemu_s_sata_3_gbits_test-01.html\">d'autres exp\u00e9riences<\/a><\/noindex> La diff\u00e9rence de vitesse de lecture et d'\u00e9criture al\u00e9atoire s'est av\u00e9r\u00e9e insignifiante. Il est possible qu'une telle grande diff\u00e9rence d'IOPS entre SATA II et SATA III soit due \u00e0 un contr\u00f4leur SATA II peu performant ou \u00e0 un pilote d\u00e9fectueux.<\/p>\n<p>Cependant, il est essentiel de v\u00e9rifier la vitesse de SATA II - vous pourriez avoir un contr\u00f4leur tout aussi lent. Dans ce cas, un passage \u00e0 un contr\u00f4leur SATA III est obligatoire.<\/p>\n<h2>SSD PCIe sur le bus PCI-e 2.0 ou 1.0<\/h2>\n<p>\nComme on le sait, les SSD les plus rapides sont les PCI-e NVMe, qui ne sont pas limit\u00e9s par les protocoles SAS ou SATA.<\/p>\n<p>Cependant, lors de l'installation de SSD PCI-e modernes, il faut tenir compte du fait que la plupart d'entre eux n'utilisent que 4 lignes PCI-e, g\u00e9n\u00e9ralement PCI-e 3.0 ou 3.1.<\/p>\n<p>Examinons maintenant le tableau des vitesses du bus PCI-e.<\/p>\n<p>Capacit\u00e9 de bande passante PCI Express, Go\/s<\/p>\n<p>An <br \/>\n de production<\/p>\n<p>Version<br \/>\nPCI Express<\/p>\n<p>Codage<\/p>\n<p>Vitesse<br \/>\nde transmission<\/p>\n<p>Capacit\u00e9 de bande passante sur x lignes<\/p>\n<p>\u00d74<br \/>\n\u00d78<br \/>\n\u00d716<\/p>\n<p>2002<br \/>\n1.0<br \/>\n8b\/10b<\/p>\n<p>0.50 Go\/s<br \/>\n1.0 Go\/s<br \/>\n2.0 Go\/s<br \/>\n4.0 Go\/s<\/p>\n<p>2007<br \/>\n2.0<br \/>\n8b\/10b<\/p>\n<p>1.0 Go\/s<br \/>\n2.0 Go\/s<br \/>\n4.0 Go\/s<br \/>\n8.0 Go\/s<\/p>\n<p>2010<br \/>\n3.0<br \/>\n128b\/130b<\/p>\n<p>1.97 Go\/s<br \/>\n3.94 Go\/s<br \/>\n7.88 Go\/s<br \/>\n15.8 Go\/s<\/p>\n<p>En installant un SSD PCI 3.0 x4 sur le bus PCI-e 2.0, il fonctionnera avec le m\u00eame nombre de lignes, mais \u00e0 une vitesse nettement inf\u00e9rieure. Le probl\u00e8me est que la vitesse lin\u00e9aire des SSD PCI-e modernes d\u00e9passe la capacit\u00e9 de bande passante du bus PCI-e 2.0, et encore plus celle du PCI-e 1.0.<\/p>\n<h3>SSD M.2 et adaptateur PCI-e<\/h3>\n<p>Il existe de bonnes options de mise \u00e0 niveau o\u00f9 nous achetons un adaptateur pour 10 dollars et installons un SSD M.2 dans le serveur, mais encore une fois, les vitesses des SSD de bonne qualit\u00e9 seront r\u00e9duites (surtout sur PCI-e 1.0), et les SSD M.2 ne sont pas toujours pr\u00eats pour des charges de travail serveur : forte durabilit\u00e9, protection de l'alimentation et stabilit\u00e9 des performances en raison du remplissage du cache SLC sur les mod\u00e8les bon march\u00e9.<\/p>\n<p>Ainsi, cette m\u00e9thode peut convenir uniquement \u00e0 un serveur avec un bus PCI-e 2.0 et n'effectuant pas de t\u00e2ches critiques.<\/p>\n<h3>SSD PCI-E 2.0 x8<\/h3>\n<p>\nLa mise \u00e0 niveau la plus \u00e9conomiquement logique est d'utiliser un SSD PCI-E 2.0 x8 pour des serveurs avec un bus PCI-e 1.0 (capacit\u00e9 de bande passante jusqu'\u00e0 2 Go\/s) et PCI-e 2.0 (jusqu'\u00e0 4 Go\/s).<\/p>\n<p>De tels SSD pour serveurs peuvent maintenant \u00eatre achet\u00e9s \u00e0 bas prix sur divers march\u00e9s en ligne, y compris en Russie.<\/p>\n<p>J'ai compos\u00e9 un tableau de ces SSD maintenant consid\u00e9r\u00e9s comme obsol\u00e8tes qui donneront un bon coup de fouet \u00e0 votre ancien serveur. \u00c0 la fin du tableau, j'ai ajout\u00e9 quelques SSD avec une interface PCI-E 3.0 x8. Peut-\u00eatre aurez-vous de la chance et les trouverez \u00e0 un prix raisonnable.<\/p>\n<p>Nom<br \/>\nTo<br \/>\nPBW<br \/>\nPCI-E<br \/>\n4k read iops, K<br \/>\n4k write iops, K<br \/>\nread, MB\/s<br \/>\nwrite, MB\/s<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusionio_iodrive2_duo_mlc_application_accelerator_review\">Fusion-io ioDrive II DUO MLC<\/a><\/noindex><br \/>\n2.4<br \/>\n32.5<br \/>\n2.0 x8<br \/>\n480<br \/>\n490<br \/>\n3000<br \/>\n2500<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SANDISK FUSION IOMEMORY SX350-1300<\/a><\/noindex><br \/>\n1.3<br \/>\n4<br \/>\n2.0 x8<br \/>\n225<br \/>\n345<br \/>\n2800<br \/>\n1300<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_px600_review\">SANDISK FUSION IOMEMORY PX600-1300<\/a><\/noindex><br \/>\n1.3<br \/>\n16<br \/>\n2.0 x8<br \/>\n235<br \/>\n375<br \/>\n2700<br \/>\n1700<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SANDISK FUSION IOMEMORY SX350-1600<\/a><\/noindex><br \/>\n1.6<br \/>\n5.5<br \/>\n2.0 x8<br \/>\n270<br \/>\n375<br \/>\n2800<br \/>\n1700<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_sx300_review\">SanDisk Fusion ioMemory SX300-3200<\/a><\/noindex><br \/>\n3.2<br \/>\n11<br \/>\n2.0 x8<br \/>\n345<br \/>\n385<br \/>\n2700<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SanDisk Fusion ioMemory SX350-3200<\/a><\/noindex><br \/>\n3.2<br \/>\n11<br \/>\n2.0 x8<br \/>\n345<br \/>\n385<br \/>\n2800<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_px600_review\">SANDISK FUSION IOMEMORY PX600<\/a><\/noindex><br \/>\n2.6<br \/>\n32<br \/>\n2.0 x8<br \/>\n350<br \/>\n385<br \/>\n2700<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/support.huawei.com\/enterprise\/en\/doc\/EDOC1000052593?section=j005\">Huawei ES3000 V2<\/a><\/noindex><br \/>\n1,6<br \/>\n8,76<br \/>\n2.0 x8<br \/>\n395<br \/>\n270<br \/>\n1550<br \/>\n1100<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/support.huawei.com\/enterprise\/en\/doc\/EDOC1000052593?section=j005\">Huawei ES3000 V2<\/a><\/noindex><br \/>\n3,2<br \/>\n17,52<br \/>\n2.0 x8<br \/>\n770<br \/>\n230<br \/>\n3100<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.emc.com\/collateral\/data-sheet\/h11411-xtremsf-ds.pdf\">EMC XtremSF<\/a><\/noindex><br \/>\n2,2<br \/>\n\u00a0<br \/>\n2.0 x8<br \/>\n340<br \/>\n110<br \/>\n2700<br \/>\n1000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/virident_flashmax_ii_mlc_application_accelerator_review_22tb\">HGST Virident FlashMAX II<\/a><\/noindex><br \/>\n2,2<br \/>\n33<br \/>\n2.0 x8<br \/>\n350<br \/>\n103<br \/>\n2700<br \/>\n1000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/documents.westerndigital.com\/\/content\/dam\/doc-library\/en_us\/assets\/public\/western-digital\/product\/hgst\/general-docs\/data-sheet-flashmax-pcie.pdf\">HGST Virident SSD FlashMAX II<\/a><\/noindex><br \/>\n4,8<br \/>\n10.1<br \/>\n2.0 x8<br \/>\n269<br \/>\n51<br \/>\n2600<br \/>\n900<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/documents.westerndigital.com\/\/content\/dam\/doc-library\/en_us\/assets\/public\/western-digital\/product\/hgst\/general-docs\/data-sheet-flashmax-pcie.pdf\">HGST Virident FlashMAX III<\/a><\/noindex><br \/>\n2,2<br \/>\n7.1<br \/>\n2.0 x8<br \/>\n531<br \/>\n59<br \/>\n2700<br \/>\n1400<\/p>\n<p>Dell Micron P420M<br \/>\n1.4<br \/>\n9.2<br \/>\n2.0 x8<br \/>\n750<br \/>\n95<br \/>\n3300<br \/>\n630<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/micron_p420m_enterprise_pcie_ssd_review\">Micron P420M<\/a><\/noindex><br \/>\n1.4<br \/>\n9.2<br \/>\n2.0 x8<br \/>\n750<br \/>\n95<br \/>\n3300<br \/>\n630<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.anandtech.com\/show\/10890\/hgst-ultrastar-sn200-accelerator-768-tb-capacity-61-gbs-read-speed-12m-iops\">HGST SN260<\/a><\/noindex><br \/>\n1.6<br \/>\n25.10<br \/>\n3.0 x8<br \/>\n1200<br \/>\n200<br \/>\n6170<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.anandtech.com\/show\/10890\/hgst-ultrastar-sn200-accelerator-768-tb-capacity-61-gbs-read-speed-12m-iops\">HGST SN260<\/a><\/noindex><br \/>\n3,2<br \/>\n17,52<br \/>\n3.0 x8<br \/>\n1200<br \/>\n200<br \/>\n6170<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/ark.intel.com\/content\/www\/ru\/ru\/ark\/products\/88731\/intel-ssd-dc-p3608-series-1-6tb-1-2-height-pcie-3-0-x8-20nm-mlc.html\">Intel P3608<\/a><\/noindex><br \/>\n3,2<br \/>\n17,5<br \/>\n3.0 x8<br \/>\n850<br \/>\n80<br \/>\n4500<br \/>\n2600<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.kingston.com\/datasheets\/DCP1000_us.pdf\">Kingston DCP1000<\/a><\/noindex><br \/>\n3,2<br \/>\n2,78<br \/>\n3.0 x8<br \/>\n1000<br \/>\n180<br \/>\n6800<br \/>\n6000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/docs.oracle.com\/cd\/E65386_01\/html\/E65387\/gokdw.html#scrolltoc\">Oracle F320<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n750<br \/>\n120<br \/>\n5500<br \/>\n1800<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/global.semi.static\/PM1725_NVMe_PCIe_SSD_Samsung_2016-1.pdf\">Samsung PM1725<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n1000<br \/>\n120<br \/>\n6000<br \/>\n2000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/ssd\/enterprise-ssd\/MZPLL3T2HMLS\/\">Samsung PM1725a<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n1000<br \/>\n180<br \/>\n6200<br \/>\n2600<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/ssd\/enterprise-ssd\/MZPLL3T2HAJQ\/\">Samsung PM1725b<\/a><\/noindex><br \/>\n3.2<br \/>\n18<br \/>\n3.0 x8<br \/>\n980<br \/>\n180<br \/>\n6200<br \/>\n2600<\/p>\n<p>\n<img decoding=\"async\" alt=\"Mise \u00e0 niveau du syst\u00e8me de stockage d&#039;un ancien serveur avec un bus PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/369c72c6f028b915a199e85fc3de3819.jpg\" style=\"display:block;margin: 0 auto;\" \/>Parmi ces SSD, les Fusion ioMemory se distinguent. Le directeur scientifique <noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/Fusion-io\">Fusion<\/a><\/noindex> \u00e9tait <noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/%D0%92%D0%BE%D0%B7%D0%BD%D1%8F%D0%BA,_%D0%A1%D1%82%D0%B8%D0%B2\">Steve Wozniak<\/a><\/noindex>. Ensuite, cette soci\u00e9t\u00e9 a \u00e9t\u00e9 achet\u00e9e par SanDisk pour 1,2 milliard de dollars. \u00c0 l'\u00e9poque, leur prix \u00e9tait de 50 000 $ chacun. Maintenant, ils peuvent \u00eatre achet\u00e9s pour quelques centaines de dollars, en \u00e9tat neuf, pour des disques d'une capacit\u00e9 d'au moins 1 To.<\/p>\n<p>Si l'on regarde le tableau, on peut voir qu'ils ont un nombre d'IOPS d'\u00e9criture assez \u00e9lev\u00e9, presque \u00e9gal \u00e0 celui des IOPS de lecture. Compte tenu de leur prix actuel, je pense qu'il vaut la peine de se pencher sur ces SSD. <\/p>\n<p>Cependant, ils ont quelques particularit\u00e9s :<\/p>\n<ol>\n<li>Ils ne peuvent pas \u00eatre utilis\u00e9s comme disques de d\u00e9marrage<\/li>\n<li>Un pilote est n\u00e9cessaire pour leur utilisation. Des pilotes existent pour presque tout, mais pour les derni\u00e8res versions de Linux, il faudra les compiler.<\/li>\n<li>La taille de secteur optimale est de 4096 octets. (512 est \u00e9galement pris en charge)<\/li>\n<li>Le pilote, dans le pire des cas, peut consommer pas mal de RAM (avec une taille de secteur de 512 octets)<\/li>\n<li>La vitesse de fonctionnement d\u00e9pend de la vitesse du processeur, donc il est pr\u00e9f\u00e9rable de d\u00e9sactiver les technologies d'\u00e9conomie d'\u00e9nergie. C'est \u00e0 la fois un avantage et un inconv\u00e9nient, car avec un processeur puissant, l'appareil peut fonctionner encore plus vite que ce qui est indiqu\u00e9 dans les sp\u00e9cifications.<\/li>\n<li>N\u00e9cessite un bon refroidissement. Pour les serveurs, cela ne devrait pas poser de probl\u00e8me.<\/li>\n<li>Non recommand\u00e9 pour ESXi, car ESXi pr\u00e9f\u00e8re les disques avec un secteur 512N, ce qui peut entra\u00eener une grande consommation de m\u00e9moire par le pilote.<\/li>\n<li>Les versions sous marque de ces SSD ne sont g\u00e9n\u00e9ralement pas prises en charge par les fournisseurs au niveau du dernier pilote de SanDisk (mars 2019)<\/li>\n<\/ol>\n<p>\nJ'ai effectu\u00e9 des tests sur Fusion ioMemory en comparaison avec un SSD serveur Intel P3700 PCI-E 3.0 x8 relativement moderne (ce dernier co\u00fbte environ 4 fois plus cher que le Fusion de capacit\u00e9 similaire). On peut aussi voir \u00e0 quel point la vitesse est r\u00e9duite \u00e0 cause du bus x4.<\/p>\n<p>Fusion PX600 1.3 To PCI-E 2.0 x8<br \/>\nIntel P3700 1.6 To PCI-E 3.0 x4<\/p>\n<p><img decoding=\"async\" alt=\"Mise \u00e0 niveau du syst\u00e8me de stockage d&#039;un ancien serveur avec un bus PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/7157ec6e43cac87fc0cdf5dd2887cfac.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<img decoding=\"async\" alt=\"Mise \u00e0 niveau du syst\u00e8me de stockage d&#039;un ancien serveur avec un bus PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/f5db5f37b300332bd787d5b2fe57b67e.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>\nOui, la vitesse de lecture lin\u00e9aire est ind\u00e9niablement r\u00e9duite pour l'Intel P3700. Selon les sp\u00e9cifications, elle devrait \u00eatre de 2800 Mo\/s, mais nous avons mesur\u00e9 1469 Mo\/s. Cependant, on peut dire qu'avec un bus PCI-e 2.0, on peut utiliser des SSD serveur PCI-E 3.0 x4 si on parvient \u00e0 les obtenir \u00e0 un prix raisonnable.<\/p>\n<h3>Conclusions<\/h3>\n<p>\nLe syst\u00e8me de disque de l'ancien serveur avec un bus PCI-E 1.0 ou 2.0 peut \u00eatre am\u00e9lior\u00e9 en utilisant des SSD, qui peuvent exploiter 8 lignes PCI-E, offrant une bande passante allant jusqu'\u00e0 4 Go\/s (PCI-E 2.0) ou 2 Go\/s (PCI-E 1.0). Il est \u00e9conomiquement plus avantageux d'utiliser des SSD PCI-E 2.0 qui sont moralement obsol\u00e8tes.<\/p>\n<p>Il existe \u00e9galement des options compromis simples li\u00e9es \u00e0 l'achat d'une cl\u00e9 CacheCade pour les contr\u00f4leurs LSI ou au remplacement du contr\u00f4leur Adaptec par une version Q.<\/p>\n<p>Et enfin, une m\u00e9thode plus banale consiste \u00e0 acheter un contr\u00f4leur RAID SATA III afin que les SSD fonctionnent \u00e0 pleine vitesse et puissent g\u00e9rer toutes les demandes de performance.<br \/>\n<br \/>Source : <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/454222\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u041f\u043e\u0447\u0435\u043c\u0443 \u0442\u0435\u043c\u043e\u0439 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0432\u044b\u0431\u0440\u0430\u043d \u0430\u043f\u0433\u0440\u0435\u0439\u0434 \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b\u041f\u043e\u043d\u044f\u0442\u043d\u043e, \u0447\u0442\u043e \u0432 \u043f\u0435\u0440\u0432\u0443\u044e \u043e\u0447\u0435\u0440\u0435\u0434\u044c \u043d\u0443\u0436\u043d\u043e, \u043a\u0430\u043a \u043f\u0440\u0430\u0432\u0438\u043b\u043e: \u0423\u0432\u0435\u043b\u0438\u0447\u0438\u0442\u044c \u043e\u043f\u0435\u0440\u0430\u0442\u0438\u0432\u043d\u0443\u044e \u043f\u0430\u043c\u044f\u0442\u044c. \u042d\u0442\u043e \u043d\u0430\u0441\u0442\u043e\u043b\u044c\u043a\u043e \u043e\u0447\u0435\u0432\u0438\u0434\u043d\u044b\u0439 \u0445\u043e\u0434, \u0447\u0442\u043e \u044f \u0434\u0430\u0436\u0435 \u043d\u0435 \u0441\u0447\u0451\u043b \u043d\u0443\u0436\u043d\u044b\u043c \u043f\u0438\u0441\u0430\u0442\u044c \u043e\u0431 \u044d\u0442\u043e\u043c \u0432 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0435 \u041f\u043e\u0441\u0442\u0430\u0432\u0438\u0442\u044c \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440(\u044b) \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u043e\u0431\u0430 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u0430 \u043d\u0430 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0432\u0435\u0440\u0441\u0438\u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u044b\u0435 \u0441\u043e\u043a\u0435\u0442\u0430\u043c\u0438 \u0441\u0435\u0440\u0432\u0435\u0440\u0430. \u0414\u043b\u044f \u0441\u0442\u0430\u0440\u044b\u0445 \u0441\u0435\u0440\u0432\u0435\u0440\u043e\u0432, \u0447\u0442\u043e \u043f\u0430\u043c\u044f\u0442\u044c, \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u044b, \u043a\u0430\u043a [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":26262,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-34884","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2 - aioseo.com -->\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/fr\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47Upgrade \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0442\u0430\u0440\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 \u0441 \u0448\u0438\u043d\u043e\u0439 PCIe 1.0 \u2014 2.0 | ProHoster\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/fr\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:01:01+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:01:01+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Am\u00e9lioration du syst\u00e8me de disque de l'ancien serveur avec un bus PCIe 1.0 \u2014 2.0 | ProHoster","description":"","canonical_url":"https:\/\/prohoster.info\/fr\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"fr_FR","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47Upgrade \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0442\u0430\u0440\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 \u0441 \u0448\u0438\u043d\u043e\u0439 PCIe 1.0 \u2014 2.0 | ProHoster","og:url":"https:\/\/prohoster.info\/fr\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:01:01+00:00","article:modified_time":"2019-10-31T19:01:01+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"34884","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-21 20:58:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 02:13:27","updated":"2026-01-21 20:58:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/fr\/wp-json\/wp\/v2\/posts\/34884","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/fr\/wp-json\/wp\/v2\/comments?post=34884"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/fr\/wp-json\/wp\/v2\/posts\/34884\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/fr\/wp-json\/wp\/v2\/media\/26262"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/fr\/wp-json\/wp\/v2\/media?parent=34884"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/fr\/wp-json\/wp\/v2\/categories?post=34884"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/fr\/wp-json\/wp\/v2\/tags?post=34884"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}