{"id":53854,"date":"2019-12-12T00:00:00","date_gmt":"2019-12-11T21:00:00","guid":{"rendered":"https:\/\/prohoster.info\/blog\/blog_prohoster\/vvedenie-v-ssd-chast-2-interfejsnaya"},"modified":"2020-02-18T14:01:47","modified_gmt":"2020-02-18T11:01:47","slug":"vvedenie-v-ssd-chast-2-interfejsnaya","status":"publish","type":"post","link":"https:\/\/prohoster.info\/hr\/blog\/administrirovanie\/vvedenie-v-ssd-chast-2-interfejsnaya","title":{"rendered":"Uvod u SSD. Dio 2. Su\u010delje","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/37fa13397c0b8ea7af2be17b51c7ed83.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nU <noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/selectel\/blog\/475304\/\">pro\u0161log dijela<\/a><\/noindex> ciklusa \u201eUvod u SSD\u201c govorili smo o povijesti nastanka diskova. Drugi dio \u0107e govoriti o su\u010deljima za interakciju s ure\u0111ajima za pohranu.<\/p>\n<p>Komunikacija izme\u0111u procesora i perifernih ure\u0111aja odvija se prema unaprijed definiranim sporazumima, nazvanim su\u010deljima. Ovi sporazumi reguliraju fizi\u010dku i softversku razinu interakcije.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<blockquote><p><b>Su\u010delje je skup sredstava, metoda i pravila interakcije izme\u0111u elemenata sustava.<\/b><\/p><\/blockquote>\n<p>\nFizi\u010dka realizacija su\u010delja utje\u010de na sljede\u0107e parametre:<\/p>\n<ul>\n<li>propusnost komunikacijskog kanala;<\/li>\n<li>maksimalan broj istovremeno povezanih ure\u0111aja;<\/li>\n<li>broj nastalih gre\u0161aka.<\/li>\n<\/ul>\n<p>\nDiskovni interfejsi su izgra\u0111eni na <b>ulazno-izlaznim portovima<\/b>, \u0161to je suprotno ulazu-izlazu preko memorije i ne zauzima prostor u adresnom prostoru procesora.<\/p>\n<h2>Paralelni i serijski portovi<\/h2>\n<p>\nPrema na\u010dinu razmjene podataka, ulazno-izlazni portovi dijele se u dvije vrste:<\/p>\n<ul>\n<li>paralelni;<\/li>\n<li>serijski.<\/li>\n<\/ul>\n<p>\nKao \u0161to i naziv sugerira, paralelni port \u0161alje odjednom rije\u010d stroja koja se sastoji od vi\u0161e bita. Paralelni port je najjednostavniji na\u010din razmjene podataka, jer ne zahtijeva slo\u017eena rje\u0161enja u sklopu. U najjednostavnijem slu\u010daju, svaki bit rije\u010di stroja \u0161alje se putem svoje signalne linije, a za povratne informacije koriste se dvije pomo\u0107ne signalne linije: <b>Podaci su spremni<\/b> i <b>Podaci su primljeni<\/b>.<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"http:\/\/www.cabledepot.com\/05DTSERPAR.html\"><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/7521e01508ceb9a7ab6c346fd55edb0e.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nParalelni portovi, na prvi pogled, savr\u0161eno se skaliraju: vi\u0161e signalnih linija \u2013 vi\u0161e bita se prenosi odjednom i, stoga, ve\u0107a propusnost. Ipak, zbog pove\u0107anja broja signalnih linija izme\u0111u njih dolazi do interferencijskog interakcije, \u0161to dovodi do izobli\u010denja prenesenih poruka.<\/p>\n<p>Serijski portovi su suprotnost paralelnim. Slanje podataka odvija se po jednom bitu odjednom, \u0161to smanjuje ukupan broj signalnih linija, ali komplicira kontroler ulazno-izlaznog ure\u0111aja. Kontroler oda\u0161ilja\u010da prima rije\u010d stroja odjednom i mora prenositi po jedan bit, dok kontroler prijemnika zauzvrat mora primati bitove i \u010duvati ih u istom redoslijedu.<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"http:\/\/www.cabledepot.com\/05DTSERPAR.html\"><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/1a264c6efc7d854fbf4513aec347f954.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nMali broj signalnih linija omogu\u0107ava nesmetano pove\u0107anje frekvencije prijenosa poruka.<\/p>\n<h2>SCSI<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/922b430a5fda8ae5e46db82db9573719.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nSmall Computer Systems Interface (SCSI) pojavio se daleke 1978. godine i izvorno je razvijen s ciljem povezivanja ure\u0111aja razli\u010ditih profila u jedinstven sustav. Specifikacija SCSI-1 predvi\u0111ala je povezivanje do 8 ure\u0111aja (zajedno s kontrolerom), kao \u0161to su:<\/p>\n<ul>\n<li>skeneri;<\/li>\n<li>trake (streameri);<\/li>\n<li>opticki pogoni;<\/li>\n<li>diskovni pogoni i drugi ure\u0111aji.<\/li>\n<\/ul>\n<p><\/p>\n<blockquote><p><b>Izvorno je SCSI nosio naziv Shugart Associates System Interface (SASI), no standardizacijski odbor nije odobrio naziv po tvrtki, te je nakon dana brainstorming-a nastao naziv Small Computer Systems Interface (SCSI). \"Otac\" SCSI-a, Larry Boucher, podrazumijevao je da \u0107e skra\u0107enica biti izgovarana kao \"sexy\", ali <noindex><a rel=\"nofollow\" href=\"http:\/\/www.endl.com\/ida.htm\">Dal Allan<\/a><\/noindex> pro\u010ditao je \"s\u0441uzzy\" (\"skazi\"). Kasnije se izgovor \"skazi\" \u010dvrsto u\u010dvrstio za ovaj standard.<\/b><\/p><\/blockquote>\n<p>\nU terminologiji SCSI povezani ure\u0111aji dijele se u dva tipa:<\/p>\n<ul>\n<li>inicijatori;<\/li>\n<li>ciljani ure\u0111aji.<\/li>\n<\/ul>\n<p>\nInicijator \u0161alje naredbu ciljanom ure\u0111aju, koji zatim \u0161alje odgovor inicijatoru. Inicijatori i ciljani ure\u0111aji povezani su na zajedni\u010dkoj SCSI sabirnici, \u010dija propusnost prema standardu SCSI-1 iznosi 5 MB\/s.<\/p>\n<p>Kori\u0161tena topologija \"zajedni\u010dka sabirnica\" name\u0107e odre\u0111ena ograni\u010denja:<\/p>\n<ul>\n<li>na krajevima sabirnice potrebni su posebni ure\u0111aji \u2014 terminatori;<\/li>\n<li>propusnost sabirnice dijeli se izme\u0111u svih ure\u0111aja;<\/li>\n<li>maksimalan broj istovremeno povezanih ure\u0111aja je ograni\u010den.<\/li>\n<\/ul>\n<p>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/www.cablesdirect.com\/store\/p\/2877.aspx\"><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/caecf6cf48e6f0c219080f93e1224206.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p>Ure\u0111aji na sabirnici identificiraju se jedinstvenim brojem, koji se naziva <b>SCSI Target ID<\/b>. Svaki SCSI ure\u0111aj u sustavu predstavljen je najmanje jednim logi\u010dkim ure\u0111ajem, \u010dija se adresacija vr\u0161i prema jedinstvenom broju unutar fizi\u010dkog ure\u0111aja <b>Logical Unit Number<\/b> (LUN).<\/p>\n<p><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/f85b1a966dbb47dea78320e27c9cbaac.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nNaredbe u SCSI \u0161alju se u obliku <b>blokova opisa naredbi<\/b> (Command Descriptor Block, CDB), koji se sastoje od operativnog koda i parametara naredbe. U standardu je opisano vi\u0161e od 200 naredbi, podijeljenih u \u010detiri kategorije:<\/p>\n<ul>\n<li><b>Mandatory<\/b> \u2014 moraju ih podr\u017eavati ure\u0111aji;<\/li>\n<li><b>Optional<\/b> \u2014 mogu biti implementirane;<\/li>\n<li><b>Vendor-specific<\/b> \u2014 koriste se od strane odre\u0111enog proizvo\u0111a\u010da;<\/li>\n<li><b>Obsolete<\/b> \u2014 zastarjele naredbe.<\/li>\n<\/ul>\n<p>\nMe\u0111u mnogim naredbama, samo su tri od njih obavezne za ure\u0111aje:<\/p>\n<ul>\n<li><b>TEST UNIT READY<\/b> \u2014 provjera spremnosti ure\u0111aja;<\/li>\n<li><b>REQUEST SENSE<\/b> \u2014 tra\u017ei kod gre\u0161ke prethodne komande;<\/li>\n<li><b>UPIT<\/b> \u2014 upit osnovnih karakteristika ure\u0111aja.<\/li>\n<\/ul>\n<p>\nNakon primanja i obrade komande, ciljni ure\u0111aj \u0161alje inicijatoru status kod koji opisuje rezultate izvr\u0161enja.<\/p>\n<p>Daljnje unapre\u0111enje SCSI (specifikacije SCSI-2 i Ultra SCSI) pro\u0161irilo je listu kori\u0161tenih komandi i pove\u0107alo broj povezivih ure\u0111aja na 16, dok se brzina razmjene podataka putem sabirnice pove\u0107ala na 640 MB\/s. Budu\u0107i da je SCSI paralelni interfejs, pove\u0107anje frekvencije razmjene podataka je bilo povezano sa smanjenjem maksimalne du\u017eine kabla i stvaralo je nelagodu u kori\u0161\u0107enju.<\/p>\n<p>Po\u010dev\u0161i od standarda Ultra-3 SCSI uvedena je podr\u0161ka za \u201evru\u0107e povezivanje\u201c \u2014 povezivanje ure\u0111aja dok je napajanje uklju\u010deno.<\/p>\n<p>Prvim poznatim SSD diskom s SCSI interfejsom smatra se M-Systems FFD-350, koji je izdat 1995. godine. Disk je imao visoku cenu i nije bio \u0161iroko rasprostranjen.<\/p>\n<p>Trenutno paralelni SCSI nije popularan interfejs za povezivanje diskova, ali set komandi se i dalje aktivno koristi u interfejsima USB i SAS.<\/p>\n<h2>ATA \/ PATA<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/0f152c456d01911a4e64b565741cb8cd.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nInterfejs <b>ATA<\/b> (Napredna tehnolo\u0161ka veza), tako\u0111e poznata kao <b>PATA<\/b> (Paralelni ATA) razvijen je od strane kompanije Western Digital 1986. godine. Tr\u017ei\u0161ni naziv standarda IDE (eng. Integrated Drive Electronics \u2014 \u201eelektronika integrisana u ure\u0111aj\u201c) nagla\u0161ava va\u017eno novinu: kontroler diska bio je ugra\u0111en u ure\u0111aj, a ne na odvojenoj pro\u0161irivoj plo\u010di.<\/p>\n<p>Re\u0161enje da se kontroler postavi unutar ure\u0111aja re\u0161ilo je nekoliko problema odjednom. Prvo, smanjila se udaljenost od skladi\u0161ta do kontrolera, \u0161to je pozitivno uticalo na performanse ure\u0111aja. Drugo, ugra\u0111eni kontroler bio je \u201eprilago\u0111en\u201c samo za odre\u0111enu vrstu diska i, prema tome, bio je jeftiniji.<\/p>\n<p><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/de2944768a139aeccef20e1688ed7baf.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nATA, kao i SCSI, koristi paralelni na\u010din ulaza-izlaza, \u0161to se odra\u017eava na kori\u0161\u0107enim kablovima. Za povezivanje diskova koriste\u0107i IDE interfejs neophodni su 40-\u017ei\u010dni kablovi, koji se tako\u0111e nazivaju trakama. U novijim specifikacijama koriste se 80-\u017ei\u010dni kablovi: vi\u0161e od polovine od njih su uzemljenja za smanjenje interferencije na visokom frekvencijama.<\/p>\n<p>Na ATA kabelu se nalazi od dva do \u010detiri konektora, od kojih se jedan priklju\u010duje na mati\u010dnu plo\u010du, a ostali na ure\u0111aje. Kada su dva ure\u0111aja spojena jednim kablom, jedno od njih mora biti konfigurirano kao <b>Master<\/b>, a drugo kao <b>Slave<\/b>. Tre\u0107i ure\u0111aj mo\u017ee biti spojen isklju\u010divo u re\u017eimu 'samo za \u010ditanje'.<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"http:\/\/www.informit.com\/articles\/article.aspx?p=2028834&amp;seqNum=3\"><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/91490f1a349198d18c6e4947fc53476d.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nPolo\u017eaj jumper-a odre\u0111uje ulogu odre\u0111enog ure\u0111aja. Pojmovi Master i Slave u odnosu na ure\u0111aje nisu sasvim to\u010dni, jer su u odnosu na kontroler svi povezani ure\u0111aji \u2013 Slaves.<\/p>\n<p>Posebno dostignu\u0107e u ATA-3 je uvo\u0111enje <b>Self-Monitoring<\/b>, <b>Analysis and Reporting Technology (S.M.A.R.T.)<\/b>. Pet kompanija (IBM, Seagate, Quantum, Conner i Western Digital) udru\u017eilo je snage i standardiziralo tehnologiju procene stanja ure\u0111aja.<\/p>\n<p>Podr\u0161ka za \u010dvrste diskove uvedena je sa \u010detvrtom verzijom standarda, objavljenom 1998. godine. Ova verzija standarda omogu\u0107ava brzinu prenosa podataka do 33.3 MB\/s.<\/p>\n<p>Standard postavlja stroge zahteve za ATA kablove:<\/p>\n<ul>\n<li>kabel mora biti ravan;<\/li>\n<li>maksimalna du\u017eina kabla je 18 in\u010da (45.7 centimetara).<\/li>\n<\/ul>\n<p>\nKratak i \u0161irok kabel bio je neudoban i ometao hla\u0111enje. Pove\u0107ati frekvenciju prenosa sa svakom slede\u0107om verzijom standarda postajalo je sve te\u017ee, a ATA-7 je radikalno re\u0161io problem: paralelni interfejs je zamenjen serijskim. Nakon toga, ATA je dobio re\u010d Paralel i postao poznat kao PATA, a sedma verzija standarda dobila je drugo ime \u2014 Serial ATA. Numeracija verzija SATA zapo\u010dela je od jedinice.<\/p>\n<h2>SATA<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/62bbd54846d285ac7545fd019935f4a4.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nStandard Serial ATA (SATA) predstavljen je 7. januara 2003. godine i re\u0161avao je probleme svog prethodnika slede\u0107im izmenama:<\/p>\n<ul>\n<li>paralelni port zamenjen je serijskim;<\/li>\n<li>\u0161irok 80-\u017ei\u010dni kabel zamenjen je 7-\u017ei\u010dnim;<\/li>\n<li>topologija 'zajedni\u010dka sabirnica' zamenjena je povezivanjem 'ta\u010dka-ta\u010dka'.<\/li>\n<\/ul>\n<p>\nIako je standard SATA 1.0 (SATA\/150, 150 MB\/s) bio neznatno br\u017ei od ATA-6 (UltraDMA\/130, 130 MB\/s), prelazak na serijski na\u010din razmene podataka bio je 'priprema terena' za pove\u0107anje brzina.<\/p>\n<p>\u0160esnaest signalnih linija za prijenos podataka u ATA zamijenjeno je s dvije uvojene parice: jedna za prijenos, druga za prijem. SATA konektori su dizajnirani za ve\u0107u otpornost na vi\u0161estruko ponovno povezivanje, a SATA 1.0 specifikacija omogu\u0107ila je \"vru\u0107e povezivanje\" (Hot Plug).<\/p>\n<blockquote><p><b>Neki pinovi na diskovima su kra\u0107i od drugih. To je u\u010dinjeno radi podr\u0161ke \"vru\u0107oj izmjeni\" (Hot Swap). Tijekom zamjene ure\u0111aj \"gubi\" i \"pronalazi\" linije u unaprijed definiranim redoslijedom.<\/b><\/p><\/blockquote>\n<p>\nNe\u0161to vi\u0161e od godine kasnije, u travnju 2004., objavljena je druga verzija SATA specifikacije. Osim pove\u0107anja brzine do 3 Gb\/s, u SATA 2.0 uvedena je tehnologija <b>Native Command Queuing<\/b> (NCQ). Ure\u0111aji koji podr\u017eavaju NCQ sposobni su samostalno organizirati redoslijed izvr\u0161enja zaprimljenih komandi radi postizanja maksimalne u\u010dinkovitosti.<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.newegg.com\/red-rocstor-6-data-transfer-cable\/p\/0ZF-00S7-00004\"><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/5a10fbfb30d403d9700136018a0d94eb.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nU sljede\u0107e tri godine, SATA radna grupa radila je na pobolj\u0161anju postoje\u0107e specifikacije, a u verziji 2.6 pojavili su se kompaktni konektori Slimline i micro SATA (uSATA). Ovi konektori su smanjena verzija originalnog SATA konektora i dizajnirani su za opti\u010dke pogone i male diskove u prijenosnicima.<\/p>\n<p>Iako je propusnost druge generacije SATA bila dovoljna za tvrde diskove, \u010dvrsti diskovi zahtijevali su vi\u0161e. U svibnju 2009. objavljena je tre\u0107a verzija SATA specifikacije s pove\u0107anom propusno\u0161\u0107u do 6 Gb\/s.<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/windowstips.ru\/chto-takoe-msata-ssd-i-chem-on-mozhet-byt-polezen-osobenno-esli-vy-ne-udovletvoreny-obshhej-skorostyu-vashego-noutbuka\"><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/0a72172e33304d39dc8fcebc24aaca71.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nPosebna pa\u017enja \u010dvrstim diskovima posve\u0107ena je u reviziji SATA 3.1. Pojavio se konektor Mini-SATA (mSATA) namijenjen za povezivanje \u010dvrstih diskova u prijenosnicima. Za razliku od Slimline i uSATA, novi konektor bio je sli\u010dan PCIe Mini, iako nije bio elektri\u010dki kompatibilan s PCIe. Osim novog konektora, SATA 3.1 mogao se pohvaliti mogu\u0107no\u0161\u0107u redoslijednog stavljanja TRIM komandi uz komande \u010ditanja i pisanja.<\/p>\n<blockquote><p><b>TRIM komanda obavje\u0161tava \u010dvrsti disk o blokovima podataka koji nemaju korisnu vrijednost. Prije SATA 3.1, izvr\u0161avanje ove komande dovodilo je do resetiranja predmemorija i obustave ulazno-izlaznih operacija uz naknadno izvr\u0161avanje TRIM komande. Ovakav pristup pogor\u0161avao je performanse diska tijekom operacija brisanja.<\/b><\/p><\/blockquote>\n<p>\nSATA specifikacija nije mogla pratiti nagli rast brzine pristupa \u010dvrstim diskovima, \u0161to je dovelo do pojave kompromisa poznatog kao SATA Express u standardu SATA 3.2 2013. godine. Umjesto da ponovno udvostru\u010de propusnost SATA, developeri su iskoristili \u0161iroko rasprostranjenu PCIe sabirnicu, \u010dija brzina prelazi 6 Gbit\/s. Diskovi koji podr\u017eavaju SATA Express dobili su vlastiti oblik pod nazivom M.2.<\/p>\n<h2>SAS<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/b962c09d48c8aca6a19381d6d8866558.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nKonkurentski standard SCSI nije mirovao i samo godinu dana nakon pojave Serial ATA, 2004. godine, preobra\u017een je u serijski su\u010delje. Ime novom su\u010delju je <b>Serial Attached SCSI<\/b> (SAS).<\/p>\n<p>Iako je SAS naslijedio SCSI skup naredbi, promjene su bile zna\u010dajne:<\/p>\n<ul>\n<li>serijsko su\u010delje;<\/li>\n<li>29-\u017ei\u010dasti kabel s napajanjem;<\/li>\n<li>povezivanje \u201eto\u010dka-to\u010dka\u201d<\/li>\n<\/ul>\n<p>\nTerminologija SCSI tako\u0111er je naslije\u0111ena. Kontroler se i dalje naziva inicijatorom, a povezani ure\u0111aji ciljnim. Svi ciljni ure\u0111aji i inicijator tvore SAS domenu. U SAS-u propusnost veze ne ovisi o broju ure\u0111aja u domeni, budu\u0107i da svaki ure\u0111aj koristi svoj dodijeljeni kanal.<\/p>\n<p>Maksimalni broj istovremeno povezanih ure\u0111aja u SAS domeni prema specifikaciji prema\u0161uje 16 tisu\u0107a, a umjesto SCSI ID-a za adresiranje koristi se identifikator <b>World-Wide Name<\/b> (WWN).<\/p>\n<blockquote><p><b>WWN je jedinstveni identifikator duljine 16 bajtova, sli\u010dan MAC adresi za SAS ure\u0111aje.<\/b><\/p><\/blockquote>\n<p>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/Serial_Attached_SCSI\"><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/0659809e755f33639caaf83606dce40d.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nIako su konektori SAS i SATA sli\u010dni, ti standardi nisu potpuno kompatibilni. Me\u0111utim, SATA disk mo\u017ee biti povezan u SAS konektor, ali ne obrnuto. Kompatibilnost izme\u0111u SATA diskova i SAS domene osigurava se putem protokola SATA Tunneling Protocol (STP).<\/p>\n<p>Prva verzija standarda SAS-1 imala je propusnost od 3 Gbit\/s, a najnovija, SAS-4, pobolj\u0161ala je ovaj pokazatelj sedam puta: 22,5 Gbit\/s.<\/p>\n<h2>PCIe<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/05251167ad57703662c9be5df62ca85f.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nPeripheral Component Interconnect Express (PCI Express, PCIe) \u2014 serijski su\u010delje za prijenos podataka, koje je nastalo 2002. godine. Razvoj je zapo\u010deo Intel, a kasnije je preba\u010den posebnoj organizaciji \u2014 PCI Special Interest Group.<\/p>\n<p>Serijsko su\u010delje PCIe nije bilo iznimka i postalo je logi\u010dki nastavak paralelnog PCI-a, koji je namijenjen za povezivanje pro\u0161irenja.<\/p>\n<p>PCI Express zna\u010dajno se razlikuje od SATA i SAS. PCIe su\u010delje ima promjenjiv broj linija. Broj linija predstavlja potencije broja dva i varira od 1 do 16.<\/p>\n<p>Termin \"linija\" u PCIe ozna\u010dava ne konkretne signalne linije, nego zaseban punodupleksni komunikacijski kanal, koji se sastoji od sljede\u0107ih signalnih linija:<\/p>\n<ul>\n<li>prijem+ i prijem-;<\/li>\n<li>prijenos+ i prijenos-;<\/li>\n<li>\u010detiri \u017eice uzemljenja.<\/li>\n<\/ul>\n<p>\nBroj PCIe linija izravno utje\u010de na maksimalnu propusnost veze. Moderni standard PCI Express 4.0 omogu\u0107uje postizanje 1.9 GB\/s po jednoj liniji i 31.5 GB\/s kada se koristi 16 linija.<\/p>\n<p><img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/e3c4ec567c596348ebba75ff1c88c933.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n\"Apetiti\" \u010dvrstih diskova rastu vrlo brzo. I SATA i SAS ne stignu pove\u0107ati svoju propusnost kako bi \"uhvatili korak\" sa SSD-ima, \u0161to je dovelo do pojave SSD diskova s povezivanjem preko PCIe.<\/p>\n<blockquote><p><b>Iako se PCIe Add-In kartice pri\u010dvr\u0161\u0107uju vijkom, PCIe podr\u017eava \"vru\u0107u zamjenu\". Kratki pinovi PRSNT omogu\u0107uju osiguranje da je kartica potpuno umetnuta u utor.<\/b><\/p><\/blockquote>\n<p>\n\u010cvrsti diskovi povezani putem PCIe regulirani su zasebnim standardom <b>Specifikacija su\u010delja za kontroler nevolatilne memorije<\/b> i dolaze u raznim oblikovnim faktorima, ali o njima \u0107emo govoriti u sljede\u0107em dijelu.<\/p>\n<h2>Daljinski diskovi<\/h2>\n<p>\nS razvojem velikih skladi\u0161ta podataka pojavila se potreba za protokolima koji omogu\u0107uju povezivanje diskova smje\u0161tenih izvan poslu\u017eitelja. Prvo rje\u0161enje u ovom podru\u010dju bio je <b>Internet SCSI<\/b> (iSCSI), razvijen od strane IBM-a i Ciscova 1998. godine.<\/p>\n<p>Ideja iSCSI protokola je jednostavna: SCSI komande \"umotavaju\" se u TCP\/IP pakete i \u0161alju preko mre\u017ee. Unato\u010d daljinskoj povezanosti, korisnicima se stvara iluzija da je disk povezan lokalno. Mre\u017ea za pohranu podataka (Storage Area Network, SAN) temeljenih na iSCSI mo\u017ee se izgraditi na postoje\u0107oj mre\u017enoj infrastrukturi. Kori\u0161tenje iSCSI znatno smanjuje tro\u0161kove organizacije SAN-a.<\/p>\n<p>iSCSI ima \"premium\" varijantu \u2014 <b>Fibre Channel Protocol<\/b> (FCP). SAN koji koristi FCP gradi se na namjenskim opti\u010dkim komunikacijskim linijama. Ovaj pristup zahtijeva dodatnu opti\u010dku mre\u017enu opremu, ali se odlikuje stabilno\u0161\u0107u i visokom propusno\u0161\u0107u.<\/p>\n<blockquote><p><b>Postoji mnogo protokola za slanje SCSI naredbi preko ra\u010dunalnih mre\u017ea. Ipak, postoji samo jedan standard koji rje\u0161ava suprotan problem i omogu\u0107ava slanje IP paketa putem SCSI sabirnice \u2014 <noindex><a rel=\"nofollow\" href=\"https:\/\/www.rfc-editor.org\/rfc\/rfc2143.txt\">IP-over-SCSI<\/a><\/noindex>.<\/b><\/p><\/blockquote>\n<p>\nVe\u0107ina protokola za organizaciju SAN koristi SCSI naredbe za upravljanje pohranjivanjem, ali postoje i iznimke, poput jednostavnog <b>ATA over Ethernet<\/b> (AoE). AoE protokol \u0161alje ATA naredbe unutar Ethernet paketa, ali se u sustavu pohrana prikazuje kao SCSI.<\/p>\n<p>S pojavom ure\u0111aja NVM Express, iSCSI i FCP protokoli vi\u0161e nisu zadovoljili rastu\u0107e zahtjeve \u010dvrstih diskova. Pojavila su se dva rje\u0161enja:<\/p>\n<ul>\n<li>izdvajanje PCI Express sabirnice izvan servera;<\/li>\n<li>izrada NVMe over Fabrics protokola.<\/li>\n<\/ul>\n<p>\nIzdvajanje PCIe sabirnice dolazi s potrebom za stvaranjem slo\u017eene sklopovske opreme, ali ne uvodi promjene u protokol.<\/p>\n<p>Protokol NVMe over Fabrics postao je dobra alternativa iSCSI i FCP. U NVMe-oF koriste se opti\u010dke komunikacijske linije i NVM Express skup naredbi.<\/p>\n<h2>DDR-T<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Uvod u SSD. Dio 2. Su\u010delje\" src=\"\/wp-content\/uploads\/2019\/12\/3fe9daef1cc011973e9cfc48e9ffe8d2.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nStandardi iSCSI i NVMe-oF rje\u0161avaju problem povezivanja udaljenih diskova kao lokalnih, dok je Intel odabrao drugi put i maksimalno pribli\u017eio lokalni disk procesoru. Odabir je pao na DIMM utore, u koje se povezuje RAM. Maksimalna propusnost DDR4 kanala iznosi 25 GB\/s, \u0161to zna\u010dajno prema\u0161uje brzinu PCIe sabirnice. Tako je nastala Intel\u00ae Optane\u2122 DC Persistent Memory \u010dvrsta memorija.<\/p>\n<p>Za povezivanje diska u DIMM utore izumljen je protokol <b>DDR-T<\/b>, fizi\u010dki i elektri\u010dni kompatibilan s DDR4, ali zahtijeva poseban kontroler koji vidi razliku izme\u0111u memorijskog modula i diska. Brzina pristupa disku manja je od brzine pristupa RAM-u, ali ve\u0107a od brzine NVMe.<\/p>\n<p>DDR-T protokol dostupan je samo s Intel\u00ae procesorima 2. generacije Cascade Lake ili novijim.<\/p>\n<h2>Zaklju\u010dak<\/h2>\n<p>\nGotovo svi su\u010delja pro\u0161la su dug put razvoja od serijskog do paralelnog prijenosa podataka. Brzine \u010dvrstih diskova brzo rastu, ju\u010der su \u010dvrsti diskovi bili rijetkost, a danas NVMe vi\u0161e ne iznena\u0111uje.<\/p>\n<blockquote><p><b>U na\u0161em laboratoriju <noindex><a rel=\"nofollow\" href=\"https:\/\/selectel.ru\/lab\/\">Selectel Lab<\/a><\/noindex> mo\u017eete sami testirati SSD i NVMe diskove.<\/b><\/p><\/blockquote>\n<p class=\"for_users_only_msg\">Samo registrirani korisnici mogu sudjelovati u anketi. <noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/auth\/login\/\">Prijavite se<\/a><\/noindex>, molimo.<\/p>\n<h2 class=\"default-block__polling-title\">Ho\u0107e li NVMe diskovi zamijeniti klasi\u010dne SSD-ove u bliskoj budu\u0107nosti?<\/h2>\n<ul class=\"poll-result\">\n<li class=\"poll-result__item\">\n<p>                <strong class=\"poll-result__data-percent  poll-result__data-percent_winner\">55.5%<\/strong>Da100<\/p>\n<\/li>\n<li class=\"poll-result__item\">\n<p>                <strong class=\"poll-result__data-percent\">44.4%<\/strong>Ne80<\/p>\n<\/li>\n<\/ul>\n<p>    Glasalo je 180 korisnika. Suzdr\u017ealo se 28 korisnika.<br \/>\n<br \/>Izvor: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/selectel\/blog\/478684\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0412 \u043f\u0440\u043e\u0448\u043b\u043e\u0439 \u0447\u0430\u0441\u0442\u0438 \u0446\u0438\u043a\u043b\u0430 \u00ab\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0432 SSD\u00bb \u043c\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u043b\u0438 \u043f\u0440\u043e \u0438\u0441\u0442\u043e\u0440\u0438\u044e \u043f\u043e\u044f\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0438\u0441\u043a\u043e\u0432. \u0412\u0442\u043e\u0440\u0430\u044f \u0447\u0430\u0441\u0442\u044c \u0440\u0430\u0441\u0441\u043a\u0430\u0436\u0435\u0442 \u043f\u0440\u043e \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u044b \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u0441 \u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u044f\u043c\u0438. \u041e\u0431\u0449\u0435\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u043c \u0438 \u043f\u0435\u0440\u0438\u0444\u0435\u0440\u0438\u0439\u043d\u044b\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0437\u0430\u0440\u0430\u043d\u0435\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u043c\u0438 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f\u043c\u0438, \u043d\u0430\u0437\u044b\u0432\u0430\u0435\u043c\u044b\u043c\u0438 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430\u043c\u0438. \u042d\u0442\u0438 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f \u0440\u0435\u0433\u043b\u0430\u043c\u0435\u043d\u0442\u0438\u0440\u0443\u044e\u0442 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f. \u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u2014 \u0441\u043e\u0432\u043e\u043a\u0443\u043f\u043d\u043e\u0441\u0442\u044c \u0441\u0440\u0435\u0434\u0441\u0442\u0432, \u043c\u0435\u0442\u043e\u0434\u043e\u0432 \u0438 \u043f\u0440\u0430\u0432\u0438\u043b \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u043c\u0435\u0436\u0434\u0443 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u0430\u043c\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-53854","post","type-post","status-publish","format-standard","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/hr\/blog\/administrirovanie\/vvedenie-v-ssd-chast-2-interfejsnaya\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"hr_HR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0432 SSD. \u0427\u0430\u0441\u0442\u044c 2. \u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u043d\u0430\u044f | ProHoster\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/hr\/blog\/administrirovanie\/vvedenie-v-ssd-chast-2-interfejsnaya\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-12-11T21:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-02-18T11:01:47+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Uvod u SSD. Dio 2. Su\u010delje | ProHoster","description":"","canonical_url":"https:\/\/prohoster.info\/hr\/blog\/administrirovanie\/vvedenie-v-ssd-chast-2-interfejsnaya","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"hr_HR","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0432 SSD. \u0427\u0430\u0441\u0442\u044c 2. \u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u043d\u0430\u044f | ProHoster","og:url":"https:\/\/prohoster.info\/hr\/blog\/administrirovanie\/vvedenie-v-ssd-chast-2-interfejsnaya","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-12-11T21:00:00+00:00","article:modified_time":"2020-02-18T11:01:47+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"53854","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-24 09:02:22","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 13:12:42","updated":"2026-01-24 09:02:22","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/hr\/wp-json\/wp\/v2\/posts\/53854","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/hr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/hr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/hr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/hr\/wp-json\/wp\/v2\/comments?post=53854"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/hr\/wp-json\/wp\/v2\/posts\/53854\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/hr\/wp-json\/wp\/v2\/media?parent=53854"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/hr\/wp-json\/wp\/v2\/categories?post=53854"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/hr\/wp-json\/wp\/v2\/tags?post=53854"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}