{"id":34884,"date":"2019-10-31T22:01:01","date_gmt":"2019-10-31T19:01:01","guid":{"rendered":"https:\/\/prohoster.info\/blog\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\/"},"modified":"2019-10-31T22:01:01","modified_gmt":"2019-10-31T19:01:01","slug":"upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","status":"publish","type":"post","link":"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","title":{"rendered":"Upgrade del sottosistema del disco del vecchio server da PCIe 1.0 a 2.0","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Upgrade del sottosistema del disco del vecchio server da PCIe 1.0 a 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/68025340a72b1acac62371764f328712.jpg\" style=\"display:block;margin: 0 auto;\" \/><b class=\"spoiler_title\">Perch\u00e9 il tema di questo articolo \u00e8 l'upgrade del sistema di archiviazione<\/b>\u00c8 chiaro che, in primo luogo, \u00e8 necessario, di norma:<\/p>\n<ol>\n<li>Aumentare la memoria RAM. \u00c8 cos\u00ec ovvio che non ho ritenuto necessario scriverne nell'articolo principale<\/li>\n<li>Installare processori aggiuntivi o sostituire entrambi i processori con versioni ad alte prestazioni supportate dai socket del server.<\/li>\n<\/ol>\n<p>\nPer i server pi\u00f9 vecchi, sia la memoria che i processori, di norma, possono essere trovati a prezzi stracciati.<\/p>\n<p>A un certo punto, ogni proprietario di un server si trova di fronte alla domanda: upgrade o nuovo server.<\/p>\n<p>Poich\u00e9 il prezzo di un nuovo server pu\u00f2 ora raggiungere milioni di rubli, molti optano per l'upgrade.<\/p>\n<p>Per un upgrade di successo, \u00e8 fondamentale utilizzare compromessi, in modo che per un costo insignificante (rispetto al prezzo di un nuovo server) otteniamo un guadagno significativo in prestazioni.<\/p>\n<p>Nell'articolo \u00e8 fornito un elenco di SSD server PCI-E 2.0 x8, che ora sono significativamente ridotti, sono indicati i controller RAID con supporto per la caching SSD e l'SSD SATA III testato su interfaccia SATA II.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nIl modo pi\u00f9 ovvio per aggiornare il sistema di archiviazione \u00e8 passare da HDD a SSD. Questo vale sia per i laptop che per i server. Nei server, probabilmente l'unica differenza \u00e8 che gli SSD possono essere facilmente configurati in RAID.<\/p>\n<p>Tuttavia, ci sono alcune complicazioni legate al fatto che potresti non avere porte SATA III su un vecchio server, e quindi dovrai sostituire o installare un controller appropriato.<\/p>\n<p>Ci sono, naturalmente, anche metodi intermedi.<\/p>\n<h2>Caching su SSD.<\/h2>\n<p>\nIn generale, questo metodo \u00e8 piuttosto adatto per database, 1C, qualsiasi accesso casuale. La velocit\u00e0 aumenta notevolmente. Per file di grandi dimensioni, video sorveglianza questo metodo \u00e8 inutile.<\/p>\n<h3>Controller RAID LSI (IBM, DELL, CISCO, Fujtsu)<\/h3>\n<p>\nA partire dalla serie 92xx, LSI ha la tecnologia CacheCade 2.0, che consente di utilizzare quasi qualsiasi SSD SATA come cache per l'array RAID. Sia in lettura che in scrittura. E persino di creare uno specchio a partire da SSD di caching.<\/p>\n<p>Con i controller brandizzati la situazione \u00e8 pi\u00f9 complessa. Questo riguarda in particolare IBM. Sar\u00e0 necessario acquistare le licenze e gli SSD per CacheCade da IBM a prezzi esorbitanti, quindi \u00e8 pi\u00f9 semplice sostituire il controller con uno LSI e acquistare la licenza hardware a un prezzo pi\u00f9 conveniente. Le licenze software costano significativamente di pi\u00f9 rispetto a quelle hardware.<\/p>\n<h3>Controller RAID Adaptec<\/h3>\n<p>\nNei controller Adaptec \u00e8 presente la tecnologia MaxCache, che consente di utilizzare anche gli SSD come cache. Siamo interessati alle versioni dei controller che terminiamo con la lettera Q.<\/p>\n<p>I controller Q possono utilizzare quasi qualsiasi SSD, non solo quelli forniti da Adaptec.<\/p>\n<ul>\n<li>A partire dalla serie 5xxx, tutti i controller supportano il raid ibrido. Il principio di questa tecnologia \u00e8 che la lettura avviene sempre da SSD quando c'\u00e8 uno specchio di uno dei dischi contenente un SSD.<\/li>\n<li>5xxxQ, ad esempio 5805ZQ. Questi controller supportano MaxCache 1.0. Solo caching in lettura.<\/li>\n<li>6xxQ, ad esempio 6805Q. MaxCache 2.0. Caching in lettura e scrittura.<\/li>\n<li>7xxQ, ad esempio 7805Q. MaxCache 3.0. Caching in lettura e scrittura.<\/li>\n<li>8xxQ ha poco senso usarlo per scopi di aggiornamento a causa dei prezzi elevati.<\/li>\n<\/ul>\n<p>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/pc-administrator\/blog\/319214\/\">Articolo sul caching SSD su Habr (controller e OS).<\/a><\/noindex><\/p>\n<h3>Tecnologie software di caching su SSD<\/h3>\n<p>\nNon tratter\u00f2 queste tecnologie. Praticamente qualsiasi sistema operativo attualmente le supporta. Mi ricordo che utilizzando btrfs, esso reindirizza automaticamente le richieste di lettura al dispositivo con la coda pi\u00f9 corta \u2014 SSD.<\/p>\n<h2>SSD SATA III su interfaccia SATA II<\/h2>\n<p>\nPoich\u00e9 non sempre \u00e8 possibile e conveniente acquistare un nuovo controller, sorge la domanda su quanto bene funzionano gli SSD SATA III su un'interfaccia obsoleta SATA II.<\/p>\n<p>Effettueremo un piccolo test. Come soggetto avremo un SSD SATA III Intel S3710 da 400 GB.<\/p>\n<p>Lettura casuale, iops<br \/>\nLatenza di lettura media, mS<br \/>\nScrittura casuale, iops<br \/>\nLatenza di scrittura media, mS<br \/>\nLettura lineare, MB\/s<br \/>\nScrittura lineare, MB\/s<\/p>\n<p>SATA II<br \/>\n21241<br \/>\n2<br \/>\n13580<br \/>\n4<br \/>\n282<br \/>\n235<\/p>\n<p>SATA III<br \/>\n68073<br \/>\n0.468<br \/>\n61392<br \/>\n0.52<br \/>\n514<br \/>\n462<\/p>\n<p>\n<b class=\"spoiler_title\">Comandi utilizzati per testare la velocit\u00e0<\/b><\/p>\n<pre><code class=\"bash\">fio --name LinRead --eta-newline=5s --filename=\/dev\/sda --rw=read --size=500m --io_size=10g --blocksize=1024k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=1 --runtime=60 --group_reporting \nfio --name LinWrite --eta-newline=5s --filename=\/dev\/sda --rw=write --size=500m --io_size=10g --blocksize=1024k --ioengine=libaio --fsync=10000 --iodepth=32 --direct=1 --numjobs=1 --runtime=60 --group_reporting\n\nfio --name RandRead --eta-newline=5s --filename=\/dev\/sda --rw=randread --size=500m --io_size=10g --blocksize=4k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=4 --runtime=60 --group_reporting\n\nfio --name RandWrite --eta-newline=5s --filename=\/dev\/sda --rw=randwrite --size=500m --io_size=10g --blocksize=4k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=4 --runtime=60 --group_reporting\n<\/code><\/pre>\n<p>Come si pu\u00f2 vedere, la differenza in termini di velocit\u00e0 lineare, IOPS e latenze \u00e8 molto significativa, quindi ha senso utilizzare solo l'interfaccia SATA III; se non \u00e8 disponibile, allora installare un controller.<\/p>\n<p>A dire il vero, per quanto riguarda <noindex><a rel=\"nofollow\" href=\"http:\/\/www.thg.ru\/storage\/ustanovka_ssd_v_sistemu_s_sata_3_gbits_test\/ustanovka_ssd_v_sistemu_s_sata_3_gbits_test-01.html\">altri esperimenti<\/a><\/noindex> la differenza nella velocit\u00e0 di lettura e scrittura casuale \u00e8 risultata trascurabile. \u00c8 possibile che una cos\u00ec grande differenza nei IOPS tra SATA II e SATA III sia stata causata dal fatto che avevo un controller SATA II particolarmente sfortunato o un driver con alcuni bug.<\/p>\n<p>Tuttavia, il fatto \u00e8 che \u00e8 necessario controllare la velocit\u00e0 di SATA II: potrebbe essere che tu abbia lo stesso controller lento. In questo caso, \u00e8 obbligatorio passare a un controller SATA III.<\/p>\n<h2>SSD PCIe su bus PCI-e 2.0 o 1.0<\/h2>\n<p>\nCome \u00e8 noto, gli SSD pi\u00f9 veloci sono quelli PCI-e NVMe, che non sono limitati dai protocolli SAS o SATA.<\/p>\n<p>Tuttavia, nell'installare gli SSD PCI-e moderni, \u00e8 necessario considerare che la maggior parte di essi utilizza solo 4 linee PCI-e, di solito PCI-e 3.0 o 3.1.<\/p>\n<p>Ora diamo un'occhiata alla tabella delle velocit\u00e0 del bus PCI-e.<\/p>\n<p>Larghezza di banda PCI Express, Gbyte\/s<\/p>\n<p>Anno <br \/>\n di produzione<\/p>\n<p>Versione<br \/>\nPCI Express<\/p>\n<p>Codifica<\/p>\n<p>Velocit\u00e0<br \/>\ntrasmettere<\/p>\n<p>Larghezza di banda su x linee<\/p>\n<p>\u00d74<br \/>\n\u00d78<br \/>\n\u00d716<\/p>\n<p>2002<br \/>\n1.0<br \/>\n8b\/10b<\/p>\n<p>0,50 Gbyte\/s<br \/>\n1.0 Gbyte\/s<br \/>\n2.0 Gbyte\/s<br \/>\n4.0 Gbyte\/s<\/p>\n<p>2007<br \/>\n2.0<br \/>\n8b\/10b<\/p>\n<p>1.0 Gbyte\/s<br \/>\n2.0 Gbyte\/s<br \/>\n4.0 Gbyte\/s<br \/>\n8.0 Gbyte\/s<\/p>\n<p>2010<br \/>\n3.0<br \/>\n128b\/130b<\/p>\n<p>1,97 Gbyte\/s<br \/>\n3,94 Gbyte\/s<br \/>\n7,88 Gbyte\/s<br \/>\n15,8 Gbyte\/s<\/p>\n<p>Installando un SSD PCI 3.0 x4 sul bus PCI-e 2.0, esso funzioner\u00e0 con lo stesso numero di linee, ma a una velocit\u00e0 significativamente inferiore. C'\u00e8 un problema in quanto le velocit\u00e0 lineari degli SSD PCI-e moderni superano la larghezza di banda del bus PCI-e 2.0 e ancor di pi\u00f9 PCI-e 1.0.<\/p>\n<h3>SSD M.2 e adattatore PCI-e<\/h3>\n<p>Ci sono buone opzioni di aggiornamento, quando acquistiamo un adattatore per 10 dollari e installiamo un SSD M.2 in un server, ma di nuovo per buoni SSD ci saranno limitazioni nelle velocit\u00e0 (soprattutto su PCI-e 1.0), e gli SSD M.2 non sempre sono pronti per carichi server: grande resistenza all'usura, protezione dell'alimentazione e stabilit\u00e0 delle caratteristiche di velocit\u00e0 a causa del riempimento della cache SLC nei modelli economici.<\/p>\n<p>Quindi questo metodo potrebbe essere adatto solo per un server con bus PCI-e 2.0 e impegnato in un lavoro non critico.<\/p>\n<h3>SSD PCI-E 2.0 x8<\/h3>\n<p>\nL'upgrade pi\u00f9 economicamente logico \u00e8 utilizzare SSD PCI-E 2.0 x8 per server con bus PCI-e 1.0 (larghezza di banda fino a 2 GB\/s) e PCI-e 2.0 (fino a 4 GB\/s).<\/p>\n<p>SSD server simili possono essere acquistati attualmente a prezzi molto convenienti sia su vari marketplace che su aste online, inclusa la Russia.<\/p>\n<p>Ho creato una tabella di questi SSD moralmente obsoleti, che possono dare nuova vita al tuo vecchio server. Alla fine della tabella ho aggiunto alcuni SSD con interfaccia PCI-E 3.0 x8. Magari avrai fortuna e li troverai a un prezzo ragionevole.<\/p>\n<p>Nome<br \/>\nTB<br \/>\nPBW<br \/>\nPCI-E<br \/>\n4k read iops, K<br \/>\n4k write iops, K<br \/>\nread, MB\/s<br \/>\nwrite, MB\/s<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusionio_iodrive2_duo_mlc_application_accelerator_review\">Fusion-io ioDrive II DUO MLC<\/a><\/noindex><br \/>\n2.4<br \/>\n32.5<br \/>\n2.0 x8<br \/>\n480<br \/>\n490<br \/>\n3000<br \/>\n2500<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SANDISK FUSION IOMEMORY SX350-1300<\/a><\/noindex><br \/>\n1.3<br \/>\n4<br \/>\n2.0 x8<br \/>\n225<br \/>\n345<br \/>\n2800<br \/>\n1300<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_px600_review\">SANDISK FUSION IOMEMORY PX600-1300<\/a><\/noindex><br \/>\n1.3<br \/>\n16<br \/>\n2.0 x8<br \/>\n235<br \/>\n375<br \/>\n2700<br \/>\n1700<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SANDISK FUSION IOMEMORY SX350-1600<\/a><\/noindex><br \/>\n1.6<br \/>\n5.5<br \/>\n2.0 x8<br \/>\n270<br \/>\n375<br \/>\n2800<br \/>\n1700<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_sx300_review\">SanDisk Fusion ioMemory SX300-3200<\/a><\/noindex><br \/>\n3.2<br \/>\n11<br \/>\n2.0 x8<br \/>\n345<br \/>\n385<br \/>\n2700<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SanDisk Fusion ioMemory SX350-3200<\/a><\/noindex><br \/>\n3.2<br \/>\n11<br \/>\n2.0 x8<br \/>\n345<br \/>\n385<br \/>\n2800<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_px600_review\">SANDISK FUSION IOMEMORY PX600<\/a><\/noindex><br \/>\n2.6<br \/>\n32<br \/>\n2.0 x8<br \/>\n350<br \/>\n385<br \/>\n2700<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/support.huawei.com\/enterprise\/en\/doc\/EDOC1000052593?section=j005\">Huawei ES3000 V2<\/a><\/noindex><br \/>\n1,6<br \/>\n8,76<br \/>\n2.0 x8<br \/>\n395<br \/>\n270<br \/>\n1550<br \/>\n1100<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/support.huawei.com\/enterprise\/en\/doc\/EDOC1000052593?section=j005\">Huawei ES3000 V2<\/a><\/noindex><br \/>\n3,2<br \/>\n17,52<br \/>\n2.0 x8<br \/>\n770<br \/>\n230<br \/>\n3100<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.emc.com\/collateral\/data-sheet\/h11411-xtremsf-ds.pdf\">EMC XtremSF<\/a><\/noindex><br \/>\n2,2<br \/>\n\u00a0<br \/>\n2.0 x8<br \/>\n340<br \/>\n110<br \/>\n2700<br \/>\n1000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/virident_flashmax_ii_mlc_application_accelerator_review_22tb\">HGST Virident FlashMAX II<\/a><\/noindex><br \/>\n2,2<br \/>\n33<br \/>\n2.0 x8<br \/>\n350<br \/>\n103<br \/>\n2700<br \/>\n1000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/documents.westerndigital.com\/\/content\/dam\/doc-library\/en_us\/assets\/public\/western-digital\/product\/hgst\/general-docs\/data-sheet-flashmax-pcie.pdf\">HGST Virident SSD FlashMAX II<\/a><\/noindex><br \/>\n4,8<br \/>\n10.1<br \/>\n2.0 x8<br \/>\n269<br \/>\n51<br \/>\n2600<br \/>\n900<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/documents.westerndigital.com\/\/content\/dam\/doc-library\/en_us\/assets\/public\/western-digital\/product\/hgst\/general-docs\/data-sheet-flashmax-pcie.pdf\">HGST Virident FlashMAX III<\/a><\/noindex><br \/>\n2,2<br \/>\n7.1<br \/>\n2.0 x8<br \/>\n531<br \/>\n59<br \/>\n2700<br \/>\n1400<\/p>\n<p>Dell Micron P420M<br \/>\n1.4<br \/>\n9.2<br \/>\n2.0 x8<br \/>\n750<br \/>\n95<br \/>\n3300<br \/>\n630<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/micron_p420m_enterprise_pcie_ssd_review\">Micron P420M<\/a><\/noindex><br \/>\n1.4<br \/>\n9.2<br \/>\n2.0 x8<br \/>\n750<br \/>\n95<br \/>\n3300<br \/>\n630<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.anandtech.com\/show\/10890\/hgst-ultrastar-sn200-accelerator-768-tb-capacity-61-gbs-read-speed-12m-iops\">HGST SN260<\/a><\/noindex><br \/>\n1.6<br \/>\n25.10<br \/>\n3.0 x8<br \/>\n1200<br \/>\n200<br \/>\n6170<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.anandtech.com\/show\/10890\/hgst-ultrastar-sn200-accelerator-768-tb-capacity-61-gbs-read-speed-12m-iops\">HGST SN260<\/a><\/noindex><br \/>\n3,2<br \/>\n17,52<br \/>\n3.0 x8<br \/>\n1200<br \/>\n200<br \/>\n6170<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/ark.intel.com\/content\/www\/ru\/ru\/ark\/products\/88731\/intel-ssd-dc-p3608-series-1-6tb-1-2-height-pcie-3-0-x8-20nm-mlc.html\">Intel P3608<\/a><\/noindex><br \/>\n3,2<br \/>\n17,5<br \/>\n3.0 x8<br \/>\n850<br \/>\n80<br \/>\n4500<br \/>\n2600<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.kingston.com\/datasheets\/DCP1000_us.pdf\">Kingston DCP1000<\/a><\/noindex><br \/>\n3,2<br \/>\n2,78<br \/>\n3.0 x8<br \/>\n1000<br \/>\n180<br \/>\n6800<br \/>\n6000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/docs.oracle.com\/cd\/E65386_01\/html\/E65387\/gokdw.html#scrolltoc\">Oracle F320<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n750<br \/>\n120<br \/>\n5500<br \/>\n1800<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/global.semi.static\/PM1725_NVMe_PCIe_SSD_Samsung_2016-1.pdf\">Samsung PM1725<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n1000<br \/>\n120<br \/>\n6000<br \/>\n2000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/ssd\/enterprise-ssd\/MZPLL3T2HMLS\/\">Samsung PM1725a<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n1000<br \/>\n180<br \/>\n6200<br \/>\n2600<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/ssd\/enterprise-ssd\/MZPLL3T2HAJQ\/\">Samsung PM1725b<\/a><\/noindex><br \/>\n3.2<br \/>\n18<br \/>\n3.0 x8<br \/>\n980<br \/>\n180<br \/>\n6200<br \/>\n2600<\/p>\n<p>\n<img decoding=\"async\" alt=\"Upgrade del sottosistema del disco del vecchio server da PCIe 1.0 a 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/369c72c6f028b915a199e85fc3de3819.jpg\" style=\"display:block;margin: 0 auto;\" \/>Tra questi SSD, spiccano i Fusion ioMemory. Il direttore scientifico <noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/Fusion-io\">Fusion<\/a><\/noindex> \u00e8 stata <noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/%D0%92%D0%BE%D0%B7%D0%BD%D1%8F%D0%BA,_%D0%A1%D1%82%D0%B8%D0%B2\">Steve Wozniak<\/a><\/noindex>. Poi questa azienda \u00e8 stata acquistata da SanDisk per 1,2 miliardi di dollari. In passato costavano da $50.000 l'uno. Ora si possono acquistare per alcune centinaia di dollari in buone condizioni per dischi con capacit\u00e0 a partire da 1TB e oltre.<\/p>\n<p>Se si osserva la tabella, si nota che hanno un numero piuttosto elevato di IOPS in scrittura praticamente uguale al numero di IOPS in lettura. Considerando il loro prezzo attuale, a mio avviso, questi SSD meritano attenzione. <\/p>\n<p>Tuttavia, presentano alcune peculiarit\u00e0:<\/p>\n<ol>\n<li>Non possono essere avviabili<\/li>\n<li>\u00c8 necessario un driver per l'utilizzo. I driver ci sono praticamente per tutto, ma per le ultime versioni di Linux dovranno essere compilati.<\/li>\n<li>La dimensione ottimale del settore \u00e8 di 4096 byte. (\u00c8 supportato anche il 512)<\/li>\n<li>Il driver, nel peggior scenario, pu\u00f2 consumare molta RAM (con dimensione del settore di 512 byte)<\/li>\n<li>La velocit\u00e0 di funzionamento dipende dalla velocit\u00e0 del processore, quindi \u00e8 meglio disabilitare le tecnologie di risparmio energetico. Questo \u00e8 sia un vantaggio che uno svantaggio, poich\u00e9 con un potente processore il dispositivo pu\u00f2 funzionare anche pi\u00f9 velocemente di quanto indicato nelle specifiche.<\/li>\n<li>Richiede un buon raffreddamento. Per i server, questo non dovrebbe essere un problema.<\/li>\n<li>Non \u00e8 raccomandato per ESXi, poich\u00e9 ESXi preferisce dischi con settore 512N, e questo potrebbe comportare un elevato consumo di memoria da parte del driver.<\/li>\n<li>Le versioni brandizzate di questi SSD, in generale, non sono supportate dai fornitori fino all'ultimo driver di SanDisk (marzo 2019)<\/li>\n<\/ol>\n<p>\nHo condotto test su Fusion ioMemory rispetto a un SSD server Intel P3700 PCI-E 3.0 x8 piuttosto moderno (quest'ultimo costa circa quattro volte di pi\u00f9 rispetto a un Fusion di capacit\u00e0 simile). Si pu\u00f2 anche osservare quanto la velocit\u00e0 venga ridotta a causa del bus x4.<\/p>\n<p>Fusion PX600 1.3TB PCI-E 2.0 x8<br \/>\nIntel P3700 1.6TB PCI-E 3.0 x4<\/p>\n<p><img decoding=\"async\" alt=\"Upgrade del sottosistema del disco del vecchio server da PCIe 1.0 a 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/7157ec6e43cac87fc0cdf5dd2887cfac.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<img decoding=\"async\" alt=\"Upgrade del sottosistema del disco del vecchio server da PCIe 1.0 a 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/f5db5f37b300332bd787d5b2fe57b67e.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>\nS\u00ec, la velocit\u00e0 di lettura lineare \u00e8 indubbiamente limitata per Intel P3700. Secondo le specifiche dovrebbe essere di 2800 MB\/sec, mentre abbiamo 1469 MB\/sec. Anche se in generale si pu\u00f2 dire che con un bus PCI-e 2.0 si possono utilizzare SSD server PCI-E 3.0 x4, se riesci a trovarli a un prezzo ragionevole.<\/p>\n<h3>Conclusioni<\/h3>\n<p>\nIl sistema di memorizzazione del vecchio server con bus PCI-E 1.0 o 2.0 pu\u00f2 essere potenziato grazie all'uso di SSD che riescono a utilizzare 8 linee PCI-E, offrendo una larghezza di banda fino a 4 GB\/s (PCI-E 2.0) o 2 GB\/s (PCI-E 1.0). \u00c8 economicamente vantaggioso farlo utilizzando SSD PCI-E 2.0, che sono ormai considerati obsoleti.<\/p>\n<p>Ci sono anche opzioni di compromesso abbastanza semplici legate all'acquisto della chiave CacheCade per i controller LSI o alla sostituzione del controller Adaptec con la versione Q.<\/p>\n<p>Un modo completamente banale \u00e8 acquistare un controller RAID SATA III affinch\u00e9 gli SSD funzionino alla massima velocit\u00e0, soddisfacendo tutte le esigenze di velocit\u00e0.<br \/>\n<br \/>Fonte: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/454222\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u041f\u043e\u0447\u0435\u043c\u0443 \u0442\u0435\u043c\u043e\u0439 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0432\u044b\u0431\u0440\u0430\u043d \u0430\u043f\u0433\u0440\u0435\u0439\u0434 \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b\u041f\u043e\u043d\u044f\u0442\u043d\u043e, \u0447\u0442\u043e \u0432 \u043f\u0435\u0440\u0432\u0443\u044e \u043e\u0447\u0435\u0440\u0435\u0434\u044c \u043d\u0443\u0436\u043d\u043e, \u043a\u0430\u043a \u043f\u0440\u0430\u0432\u0438\u043b\u043e: \u0423\u0432\u0435\u043b\u0438\u0447\u0438\u0442\u044c \u043e\u043f\u0435\u0440\u0430\u0442\u0438\u0432\u043d\u0443\u044e \u043f\u0430\u043c\u044f\u0442\u044c. \u042d\u0442\u043e \u043d\u0430\u0441\u0442\u043e\u043b\u044c\u043a\u043e \u043e\u0447\u0435\u0432\u0438\u0434\u043d\u044b\u0439 \u0445\u043e\u0434, \u0447\u0442\u043e \u044f \u0434\u0430\u0436\u0435 \u043d\u0435 \u0441\u0447\u0451\u043b \u043d\u0443\u0436\u043d\u044b\u043c \u043f\u0438\u0441\u0430\u0442\u044c \u043e\u0431 \u044d\u0442\u043e\u043c \u0432 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0435 \u041f\u043e\u0441\u0442\u0430\u0432\u0438\u0442\u044c \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440(\u044b) \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u043e\u0431\u0430 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u0430 \u043d\u0430 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0432\u0435\u0440\u0441\u0438\u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u044b\u0435 \u0441\u043e\u043a\u0435\u0442\u0430\u043c\u0438 \u0441\u0435\u0440\u0432\u0435\u0440\u0430. \u0414\u043b\u044f \u0441\u0442\u0430\u0440\u044b\u0445 \u0441\u0435\u0440\u0432\u0435\u0440\u043e\u0432, \u0447\u0442\u043e \u043f\u0430\u043c\u044f\u0442\u044c, \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u044b, \u043a\u0430\u043a [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":26262,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-34884","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"it_IT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47Upgrade \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0442\u0430\u0440\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 \u0441 \u0448\u0438\u043d\u043e\u0439 PCIe 1.0 \u2014 2.0 | ProHoster\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:01:01+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:01:01+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Aggiornamento del sistema di memorizzazione del vecchio server con bus PCIe 1.0 - 2.0 | ProHoster","description":"","canonical_url":"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"it_IT","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47Upgrade \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0442\u0430\u0440\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 \u0441 \u0448\u0438\u043d\u043e\u0439 PCIe 1.0 \u2014 2.0 | ProHoster","og:url":"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:01:01+00:00","article:modified_time":"2019-10-31T19:01:01+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"34884","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-21 20:58:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 02:13:27","updated":"2026-01-21 20:58:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/posts\/34884","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/comments?post=34884"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/posts\/34884\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/media\/26262"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/media?parent=34884"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/categories?post=34884"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/tags?post=34884"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}