{"id":56401,"date":"2020-02-12T00:00:00","date_gmt":"2020-02-11T21:00:00","guid":{"rendered":"https:\/\/prohoster.info\/blog\/blog_prohoster\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit"},"modified":"2020-02-18T14:04:41","modified_gmt":"2020-02-18T11:04:41","slug":"besperebojniki-apc-smart-ups-i-kak-ih-gotovit","status":"publish","type":"post","link":"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","title":{"rendered":"UPS APC Smart UPS, e come prepararli","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Tra la vasta gamma di UPS, i pi\u00f9 comuni nei server di livello base sono gli Smart UPS della APC (ora Schneider Electric). La loro straordinaria affidabilit\u00e0 e il basso prezzo sul mercato dell'usato spingono i sistemisti a collegare senza troppi pensieri questi UPS nei rack, cercando di estrarre il massimo profitto da hardware di 10-15 anni fa semplicemente sostituendo le batterie. Purtroppo, non sempre questo porta ai risultati attesi. Proviamo a capire cosa fare affinch\u00e9 il vostro UPS funzioni \"come nuovo\".<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<h3>Scelta delle batterie<\/h3>\n<p>\nTutti gli articoli e le discussioni sui forum riguardanti la scelta delle batterie per UPS spesso assomigliano a discussioni sulla scelta dell'olio motore per auto\/moto. Proveremo a non somigliare a loro, ma capire i principi fondamentali nella scelta delle batterie utilizzando il produttore CSB come esempio. <\/p>\n<p>Vediamo che hanno una serie di diverse linee di batterie: GP, GPL, HR, HRL, UPS, TPL. <\/p>\n<p>Iniziamo a leggere: GP, GPL \u2014 batterie di uso universale <b>per piccoli e medi carichi di scarica.<\/b>. Consigliate per l'uso in sistemi di sicurezza e antincendio e UPS. Non fanno per noi. Anche se, in effetti, sono quelle che vengono acquistate pi\u00f9 frequentemente, senza che i compratori si preoccupino di esaminare le loro caratteristiche. <\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS, e come prepararli\" src=\"\/wp-content\/uploads\/2020\/02\/8daafaf7943d755075773d981e84d94c.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nLa serie HR \u2014 batterie ad alta capacit\u00e0 energetica che consentono una profonda scarica (fino all'11% della capacit\u00e0 residua), particolarmente utili quando sono necessari elevati carichi di scarica. La differenza delle batterie \"H\" \u00e8 una speciale progettazione della griglia, che consente di aumentare la potenza di uscita del 20%. Sono particolarmente adatte per l'uso in impianti energetici potenti e UPS.<\/p>\n<p>La lettera \"L\" nella serie indica che queste sono batterie con una durata maggiore (Long Life) in modalit\u00e0 di funzionamento in riserva fino a 10 anni.<\/p>\n<p>E infine, la serie UPS \u2014 \u00e8 una batteria appositamente progettata per l'uso in alta intensit\u00e0 di corrente con tempi di scarica brevi.<\/p>\n<p>Personalmente, ho a lungo scelto tra UPS e HRL, ma ho deciso di optare per HRL. Purtroppo, per capire come si comporteranno nel lavoro prolungato, dovremo aspettare circa 5 anni, e il necroposting non \u00e8 approvato. Pertanto, consideriamo che questa sia una mia scelta personale e non cercher\u00f2 di imporla. Tuttavia, dovete capire che \u00e8 necessario scegliere batterie ad alta corrente, poich\u00e9 devono essere in grado di rilasciare tutta la capacit\u00e0 accumulata in 20-30 minuti. <\/p>\n<h3>Selezione dell'assemblaggio delle batterie<\/h3>\n<p>\nConsiderando che nell'assemblaggio si utilizzano pi\u00f9 batterie, \u00e8 estremamente desiderabile che abbiano caratteristiche identiche. Infatti, una batteria di scarsa qualit\u00e0 porter\u00e0 al malfunzionamento di tutto l'assemblaggio.<\/p>\n<p>Circa 5 anni fa, ho scoperto l'azienda Rostov \"Bastion\", che produce tester di capacit\u00e0 di batterie con il marchio \"Skat\". Non mi permetto di affermare la perfezione nella precisione delle misurazioni, ma per valutare il livello: ideale-vivo-ancora utile-morto, questo tester \u00e8 pi\u00f9 che sufficiente. <\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS, e come prepararli\" src=\"\/wp-content\/uploads\/2020\/02\/7390b5c6865ebe74998c6d6494c4e548.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nIn linea di principio, si pu\u00f2 misurare la capacit\u00e0 caricando e scaricando banalmente usando un cronometro e una lampada da automobile da 21W (che fornisce un carico di circa 1A) insieme a un tester, ma \u00e8 un processo lungo e spesso noioso.<\/p>\n<p>In ogni caso, cerchiamo di installare batterie nuove della stessa partita e speriamo di avere fortuna. <\/p>\n<h3>Elettricit\u00e0 \u2013 \u00e8 la scienza dei contatti<\/h3>\n<p>\nUn cattivo contatto in un assemblaggio di 4 batterie annuller\u00e0 tutti i vostri sforzi, quindi smontiamo l'assemblaggio con grande cautela. Di solito, negli UPS si usano connettori per batterie con ganci, che possono facilmente rompersi se tirati via. Pertanto, utilizziamo un piccolo cacciavite piatto, lo inseriamo nel connettore come mostrato nell'immagine e lo rimuoviamo lentamente senza sforzi eccessivi. Come suggerito da un collega nei commenti \u2014 bisogna semplicemente tirare il rivestimento di plastica, non il cavo. Il connettore si stacca con un leggero scatto.<\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS, e come prepararli\" src=\"\/wp-content\/uploads\/2020\/02\/07d704acf5b9c5a92b2ddf6e05f89f2a.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nPer quanto riguarda il corretto collegamento dei cavi, penso che sia superfluo scriverne. Se siete entrati dentro l'UPS, sapete sicuramente il principio del collegamento in serie delle batterie. E per gli altri: carta e penna o smartphone con fotocamera. Alla fine dell'assemblaggio, per essere sicuri, misuriamo la tensione sull'assemblaggio e la confrontiamo con quella che dovrebbe essere in base al numero di batterie.<\/p>\n<h3>\"Ho fatto tutto come scritto, ma non ha funzionato\"<\/h3>\n<p>\nE ora inizia la parte pi\u00f9 interessante. L'UPS, durante il suo funzionamento, esegue periodicamente (di solito ogni 7 o 14 giorni, a seconda delle impostazioni) una breve calibrazione della batteria. Si commuta in modalit\u00e0 batteria e misura la tensione immediatamente e dopo un breve intervallo. Il risultato \u00e8 un coefficiente di correzione relativo alla \"vitalit\u00e0 della batteria\", che viene registrato. Con il progressivo deterioramento della batteria, lo stato di questo registro diminuisce. Sulla base di ci\u00f2, l'UPS calcola il tempo rimanente di funzionamento a batteria. E a un certo punto, rendendosi conto che la situazione \u00e8 critica, l'UPS accende l'indicatore che richiede la sostituzione della batteria. Tuttavia, quando eseguiamo la sostituzione, l'UPS non ne \u00e8 a conoscenza! Lo stato del registro \"vitalit\u00e0 della batteria\" rimane invariato. Dobbiamo correggerlo.<\/p>\n<p>Ci sono due strade da percorrere. La prima via, semplice e veloce, consiste nel fare una calibrazione completa dell'UPS. Per fare ci\u00f2, bisogna caricarlo oltre il 35% e avviare la calibrazione, ad esempio tramite il programma PowerChute. Questo funziona circa la met\u00e0 delle volte. Perch\u00e9 non sempre \u2013 \u00e8 un mistero. Pertanto, seguiamo la strada lunga, ma pi\u00f9 affidabile.<\/p>\n<p>Avremo bisogno di: un computer con porta COM, un cavo originale (ad esempio 940-0024C), il programma UpsDiag 2.0 (per la sicurezza del tuo UPS, un collega consiglia di utilizzare meglio apcfix in modalit\u00e0 gratuita. Non posso dire altro a riguardo se non che sconsiglio categoricamente di premere qualsiasi cosa in UpsDiag tranne la correzione del registro 0. <i>soprattutto il pulsante di correzione automatica dell'errore della batteria<\/i>) e <noindex><a rel=\"nofollow\" href=\"http:\/\/www.apcupsd.com\/manual\/manual.html#configuring-your-eeprom\">tabella dei valori di calibrazione<\/a><\/noindex>. Ci interessa il valore del registro 0. Nella tabella \u00e8 indicato un valore per batterie ideali, sferiche, nel vuoto. Qualsiasi batteria reale dar\u00e0 dopo la calibrazione un valore inferiore, ma non molto.<\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS, e come prepararli\" src=\"\/wp-content\/uploads\/2020\/02\/93542115e332bece7803efac1c88a284.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nPrendiamo come esempio un UPS reale SUA1500RMI2U. Al momento della sostituzione della batteria, UpsDiag mostrava il valore del registro 0 \u2013 42. Cio\u00e8, le batterie sono morte. Il valore di calibrazione dalla tabella \u2013 A1. <\/p>\n<p>Iniziamo a correggere. Per prima cosa <b>scolleghiamo la scheda di rete dall'UPS<\/b>. La presenza della scheda di rete non ti permetter\u00e0 di correggere il registro. Perch\u00e9 \u2013 \u00e8 una domanda per gli ingegneri APC. Fortunatamente, pu\u00f2 essere rimossa a caldo, senza spegnere l'UPS. <\/p>\n<p>Colleghiamo il cavo, avviamo UpsDiag, andiamo nella scheda \"Calibrazione\" e controlliamo lo stato del registro 0. Annotiamo su carta, facciamo clic destro su di esso \u2013 Modifica. Portiamo il valore al valore della tabella di calibrazione \u2013 A1. Se nella tabella non c'\u00e8 il tuo UPS, allora in linea di principio puoi alzarlo a FF. Non c'\u00e8 nulla di male in questo, a parte un UPS sorpreso che mostrer\u00e0 di essere pronto a mantenere il carico fino alla seconda venuta. <\/p>\n<p>Poi dobbiamo aspettare che la batteria si carichi al 100%, caricare l'UPS al 35% o poco pi\u00f9 e avviare la calibrazione. Al termine della calibrazione, controlliamo di nuovo il valore nel registro 0 e lo confrontiamo con quello annotato su carta. Nel sopra citato SUA1500RMI2U con nuove batterie HRL1234W, il valore \u00e8 diventato \u2013 98, che in linea di principio non \u00e8 molto lontano dal valore di calibrazione A1.<\/p>\n<p>Dopo tutto, facciamo ricaricare di nuovo fino al 100%, scollegiamo il cavo COM, rimettiamo la scheda di rete e auguriamo all'UPS una lunga e felice vita a beneficio del nostro rack server.<\/p>\n<p>A proposito, le schede di rete, come l'AP9619, sono scese di prezzo anche nel mercato secondario a valori incredibili. Ma come prepararle (reset della password, aggiornamento del firmware, configurazione) \u00e8 un argomento per un articolo a parte.<br \/>\n<br \/>Fonte: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/487802\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric). \u0412\u0435\u043b\u0438\u043a\u043e\u043b\u0435\u043f\u043d\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0438\u0437\u043a\u0430\u044f \u0446\u0435\u043d\u0430 \u043d\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u043c \u0440\u044b\u043d\u043a\u0435, \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u044e\u0442 \u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u0441\u0438\u0441\u0430\u0434\u043c\u0438\u043d\u044b, \u043e\u0441\u043e\u0431\u043e \u043d\u0435 \u0437\u0430\u0434\u0443\u043c\u044b\u0432\u0430\u044f\u0441\u044c, \u0443\u0442\u044b\u043a\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u043e\u0439\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u043c\u0438 \u0418\u0411\u041f \u0438 \u043f\u044b\u0442\u0430\u044e\u0442\u0441\u044f \u0432\u044b\u0442\u044f\u043d\u0443\u0442\u044c \u0441 \u0436\u0435\u043b\u0435\u0437\u043e\u043a 10-15 \u043b\u0435\u0442\u043d\u0435\u0439 \u0434\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0443\u043c \u043f\u0440\u043e\u0444\u0438\u0442\u0430 \u0431\u0430\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u043e\u0439 \u0430\u043a\u043a\u0443\u043c\u0443\u043b\u044f\u0442\u043e\u0440\u043e\u0432. \u041a \u0441\u043e\u0436\u0430\u043b\u0435\u043d\u0438\u044e \u043d\u0435 \u0432\u0441\u0435\u0433\u0434\u0430 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-56401","post","type-post","status-publish","format-standard","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.0.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.0.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"it_IT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-02-11T21:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-02-18T11:04:41+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47UPS APC Smart, e come prepararli | ProHoster","description":"Tra gli innumerevoli gruppi di continuit\u00e0, i pi\u00f9 comuni nei server di livello entry sono gli Smart UPS della APC (ora parte di Schneider Electric).","canonical_url":"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"it_IT","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster","og:description":"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).","og:url":"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-02-11T21:00:00+00:00","article:modified_time":"2020-02-18T11:04:41+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"56401","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 19:25:39","updated":"2022-09-29 13:07:34","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/posts\/56401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/comments?post=56401"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/posts\/56401\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/media?parent=56401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/categories?post=56401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/tags?post=56401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}