{"id":79649,"date":"2020-04-29T07:42:06","date_gmt":"2020-04-29T05:42:06","guid":{"rendered":"https:\/\/prohoster.info\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br"},"modified":"2020-04-29T07:42:06","modified_gmt":"2020-04-29T05:42:06","slug":"extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","status":"publish","type":"post","link":"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","title":{"rendered":"\u00abExtreme Extended Edge\u00bb, o commutazione basata sullo standard IEEE 802.1BR","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>La soluzione \u00abExtreme Extended Edge\u00bb (nota anche come Virtual Port Extender \u2013 VPEX) \u00e8 una nuova tecnologia, il cui supporto \u00e8 stato introdotto per la prima volta nel sistema operativo EXOS, a partire dalla versione 22.5. La soluzione stessa si basa sullo standard IEEE 802.1BR (Bridge Port Extension) e con il rilascio di EXOS 22.5 \u00e8 stato aggiunto il supporto per la nuova linea hardware ExtremeSwitching V400.<\/p>\n<p><img decoding=\"async\" alt=\"\u00abExtreme Extended Edge\u00bb, o commutazione basata sullo standard IEEE 802.1BR\" src=\"\/wp-content\/uploads\/2020\/04\/ea282e49e9957cdd295691a0d945a049.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\n\u00abVPEX Bridge\u00bb \u00e8 uno switch virtuale composto da componenti come \u2014 Controlling Bridge (CB) e Bridge Port Extender (BPE). Per garantire la ridondanza, \u00e8 possibile collegare due CB all'interno di uno switch virtuale utilizzando la tecnologia MLAG. Il design di questo switch virtuale ricorda uno switch chassis classico o uno stack di switch. Se nel funzionamento del \u00abControl Plane\u00bb questo \u00e8 in gran parte vero, il funzionamento del \u00abData Plane\u00bb differisce piuttosto radicalmente. Infatti, il compito dell'802.1br \u00e8 quello di collegare una porta remota a un servizio MAC (Media Access Control) locale, isolando nel contempo il traffico delle porte remote.<\/p>\n<h4><b>Controlling Bridge<\/b><\/h4>\n<p><\/p>\n<ul>\n<li> Unico punto di controllo<\/li>\n<li> Tutta la configurazione avviene localmente sul CB<\/li>\n<li> Il supporto VPEX deve essere attivato, \u00e8 necessario un riavvio per cambiare la modalit\u00e0 operativa<\/li>\n<li> CB \u00e8 sempre lo slot n\u00ba 1<\/li>\n<li> Nell'attuale rilascio, il CB supporta il collegamento simultaneo fino a 48 BPE<\/li>\n<li> La modalit\u00e0 SV \u00e8 supportata su determinate piattaforme hardware (attualmente X670G2 e X690, altre piattaforme saranno aggiunte man mano che usciranno)<\/li>\n<li> Le licenze EXOS si applicano solo al CB<\/li>\n<li> VPEX non richiede licenze aggiuntive<\/li>\n<li> Risponde interamente all'elaborazione del data-plane e al filtraggio del traffico<\/li>\n<li> Contiene una rappresentazione virtuale di ogni porta \u00abextended\u00bb<\/li>\n<\/ul>\n<p><\/p>\n<h4><b>Bridge Port Extender<\/b><\/h4>\n<p><\/p>\n<ul>\n<li> I dispositivi BPE sono gestiti come slot di uno switch chassis<\/li>\n<li> Gli slot BPE sono numerati da 100 a 162<\/li>\n<\/ul>\n<p><\/p>\n<pre><code class=\"plaintext\">Slot-1 VPEX X690-48x-2q-4c.3 # show slot\nSlots    Type                 Configured           State       Ports  Flags\n-------------------------------------------------------------------------------\nSlot-1   X690-48x-2q-4c       X690-48x-2q-4c       Operational   72   M\nSlot-100 V400-48t-10GE4       V400-48t-10GE4       Operational   52   M\nSlot-101 V400-48t-10GE4       V400-48t-10GE4       Operational   52   M\nSlot-102 V400-48t-10GE4       V400-48t-10GE4       Operational   52   M\nSlot-103 V400-48t-10GE4       V400-48t-10GE4       Operational   52   M\n<\/code><\/pre>\n<p><\/p>\n<ul>\n<li> Non \u00e8 necessaria una connessione consolle o Out-of-Band IP al BPE<\/li>\n<li> Tutta la configurazione, il monitoraggio, il troubleshooting e la diagnostica avviene tramite l'interfaccia CB<\/li>\n<\/ul>\n<p><\/p>\n<pre><code class=\"plaintext\">Slot-1 VPEX X670G2-48x-4q.8 # config vlan v100 add port 100:1,100:3\n*Slot-1 VPEX X670G2-48x-4q.9 # show port 100:1-3 statistics no-refresh\nPort   Link      Tx Pkt     Tx Byte     Rx Pkt     Rx Byte  Rx Pkt   Tx Pkt\n       State      Count       Count      Count       Count   Mcast    Mcast\n====== ===== ========== =========== ========== =========== ======= ========\n100:1  A     2126523437 &gt;9999999999          0           0       0    14383\n100:2  R              0           0          0           0       0        0\n100:3  A          21824     4759804 2126738453 &gt;9999999999       0    14383\n====== ===== ========== =========== ========== =========== ======= ========\n<\/code><\/pre>\n<p><\/p>\n<ul>\n<li> I BPE non effettuano commutazione locale. Di conseguenza, tutto il traffico viene tunnelizzato fino al CB e, se necessario, per eseguire il forwarding alla porta adiacente dello stesso slot BPE, torna indietro. (Il BPE riceve il pacchetto, aggiunge l'intestazione E-TAG e lo invia alla porta upstream)<\/li>\n<\/ul>\n<p>\nPer operare come BPE \u00e8 stata presentata una nuova piattaforma hardware ExtremeSwitching V400. Questa include espansori di porte con 24\/48 porte 10\/100\/1000 Base-T con o senza supporto PoE. Nei modelli da 24 porte ci sono due porte da 10G, nei modelli da 48 porte ci sono quattro porte da 10G.<\/p>\n<p><img decoding=\"async\" alt=\"\u00abExtreme Extended Edge\u00bb, o commutazione basata sullo standard IEEE 802.1BR\" src=\"\/wp-content\/uploads\/2020\/04\/9575a2617f71bd74de9cc71a538d8a65.png\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<h4><b>Caratteristiche di funzionamento<\/b><\/h4>\n<p>\nSono supportate topologie con uno o due CB e fino a quattro BPE connessi in cascata. Le porte cascabili possono essere aggregate in un LAG (fino a 4 porte per i modelli V400-48t\/p). Le stazioni finali possono connettersi a diverse slot BPE tramite LAG.<\/p>\n<p><img decoding=\"async\" alt=\"\u00abExtreme Extended Edge\u00bb, o commutazione basata sullo standard IEEE 802.1BR\" src=\"\/wp-content\/uploads\/2020\/04\/0fa7476e2c1edc2a1d26705f7db3d456.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nLa rilevazione e il funzionamento del BPE si basano su protocolli quali:<\/p>\n<ul>\n<li> LLDP \u2013 rilevazione iniziale e determinazione del tipo e delle capacit\u00e0 del dispositivo connesso<\/li>\n<li> ECP \u2013 \"Edge Control Protocol\" trasporto per PE-CSP<\/li>\n<li> PE-CSP \u2013 \"Port Extender Control and Status Protocol\" per la configurazione e il controllo del BPE con il Controlling Bridge<\/li>\n<li> LACP \u2013 installazione LAG tra i porti \u00abcascade\u00bb  \u00abupstream\u00bb<\/li>\n<\/ul>\n<p>\nSe viene utilizzato un design di alta disponibilit\u00e0 con due CB e MLAG, al riavvio di un CB, i BPE continueranno a inviare traffico attraverso il Controlling Bridge rimanente. Se invece l'unico CB viene riavviato, i BPE disattiveranno amministrativamente le loro porte \"extended\". <br \/>\nPer facilitare la configurazione di topologie con 2 CB \u00e8 stata aggiunta la possibilit\u00e0 di configurare le porte MLAG di entrambi i peer da qualsiasi dei CB. La modalit\u00e0 \u00e8 chiamata \"mlag orchestration\", in cui i peer sincronizzano parte della configurazione relativa alle impostazioni delle porte MLAG. La configurazione \u00e8 simile alla configurazione dei \"virtual-router\" personalizzati.<\/p>\n<pre><code class=\"plaintext\">Slot-1 VPEX X670G2-48x-4q.11 # start orchestration mlag \"bottom\"\n(orchestration bottom) Slot-1 VPEX X670G2-48x-4q.12 # exit\nSlot-1 VPEX X670G2-48x-4q.13 #\n<\/code><\/pre>\n<p>\nLa funzionalit\u00e0 \u00abControlling Bridge\u00bb \u00e8 disponibile dopo l'installazione di un modulo gratuito per EXOS, che ha l'estensione .xmod. In questo stesso modulo sono contenuti i pacchetti di aggiornamento per BPE. Infatti, quando CB e BPE si riconoscono, il CB verifica la versione del firmware installata su BPE e, se necessario, la aggiorna automaticamente.<\/p>\n<p>Le caratteristiche sopra elencate consentono di sostituire il modulo BPE in modo semplice e veloce, se necessario. Poich\u00e9 i moduli BPE non memorizzano la configurazione e non sono legati nel sistema, subito dopo la sostituzione del dispositivo e l'accensione, il BPE verr\u00e0 riconosciuto dal CB e verr\u00e0 applicata la configurazione esistente; inoltre, se necessario, verr\u00e0 aggiornato il firmware.<\/p>\n<p>Questa soluzione \u00e8 particolarmente adatta per reti con un predominantemente traffico Nord\/Sud, come reti di campus, reti aziendali nei settori della logistica, dell'istruzione, dei centri business e altri. E per ribadirlo, i vantaggi delle reti costruite sulla soluzione \u00abExtreme Extended Edge\u00bb saranno:<\/p>\n<ul>\n<li> Riduzione del numero di livelli dell'architettura di rete tradizionale dal punto di vista della configurazione e della gestione<\/li>\n<li> Semplicit\u00e0 di scalabilit\u00e0 e implementazione<\/li>\n<li> Nessuna necessit\u00e0 di avere connessioni di console dedicate o di gestione OOV ai moduli BPE <\/li>\n<li> Riduzione delle licenze (se necessario, vengono applicate solo al CB)<\/li>\n<li> Unico punto di configurazione, monitoraggio e troubleshooting<\/li>\n<li> Visualizzazione nel NMS come un unico switch<\/li>\n<li> Nessuna necessit\u00e0 di ulteriore formazione e ampliamento del personale<\/li>\n<\/ul>\n<p>Fonte: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/extremenetworks\/blog\/420369\/\">habr.com<\/a> <\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5. \u0421\u0430\u043c\u043e \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043e \u043d\u0430 \u0431\u0430\u0437\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR (Bridge Port Extension), \u0438 \u0432 \u0440\u0430\u043c\u043a\u0430\u0445 \u0440\u0435\u043b\u0438\u0437\u0430 EXOS 22.5 \u0431\u044b\u043b\u0430 \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d\u0430 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043d\u043e\u0432\u043e\u0439 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u044b\u0439 \u043b\u0438\u043d\u0435\u0439\u043a\u0438 ExtremeSwitching V400 \u00abVPEX Bridge\u00bb \u044d\u0442\u043e [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":79650,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-79649","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"it_IT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u00abExtreme Extended Edge\u00bb, \u0438\u043b\u0438 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u044f \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-04-29T05:42:06+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-04-29T05:42:06+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47\u00abExtreme Extended Edge\u00bb, ovvero switching basato sullo standard IEEE 802.1BR | ProHoster","description":"La soluzione \u00abExtreme Extended Edge\u00bb (nota anche come Virtual Port Extender \u2013 VPEX) \u00e8 una nuova tecnologia, il cui supporto \u00e8 stato presentato per la prima volta nel sistema operativo EXOS, a partire dalla release 22.5.","canonical_url":"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"it_IT","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u00abExtreme Extended Edge\u00bb, \u0438\u043b\u0438 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u044f \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR | ProHoster","og:description":"\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5.","og:url":"https:\/\/prohoster.info\/it\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-04-29T05:42:06+00:00","article:modified_time":"2020-04-29T05:42:06+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"79649","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 16:34:38","updated":"2022-10-05 23:27:37","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/posts\/79649","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/comments?post=79649"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/posts\/79649\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/media\/79650"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/media?parent=79649"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/categories?post=79649"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/it\/wp-json\/wp\/v2\/tags?post=79649"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}