1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืžื‘ื•ื

ืฆื”ืจื™ื™ื ื˜ื•ื‘ื™ื ื—ื‘ืจื™ื! ื”ื•ืคืชืขืชื™ ืœืฉื™ื ืœื‘ ืฉืื™ืŸ ื”ืจื‘ื” ืžืืžืจื™ื ืขืœ Habrรฉ ื”ืžื•ืงื“ืฉื™ื ืœืžื•ืฆืจื™ื ืฉืœ ืกืคืง ื›ืžื• [Extreme Networks](https://tssolution.ru/katalog/extreme). ื›ื“ื™ ืœืชืงืŸ ื–ืืช ื•ืœื”ืฆื™ื’ ืืชื›ื ืงืจื•ื‘ ื™ื•ืชืจ ืœืงื• ื”ืžื•ืฆืจื™ื ืฉืœ ืืงืกื˜ืจื™ื, ืื ื™ ืžืชื›ื ืŸ ืœื›ืชื•ื‘ ืกื“ืจื” ืงืฆืจื” ืฉืœ ืžืกืคืจ ืžืืžืจื™ื ื•ืื ื™ ืจื•ืฆื” ืœื”ืชื—ื™ืœ ืขื ืžืชื’ื™ื ืขื‘ื•ืจ Enterprise.

ื”ืกื“ืจื” ืชื›ืœื•ืœ ืืช ื”ืžืืžืจื™ื ื”ื‘ืื™ื:

  • ืกืงื™ืจื” ืฉืœ ืžืชื’ื™ Extreme Enterprise
  • ืขื™ืฆื•ื‘ ืจืฉืช ืืจื’ื•ื ื™ืช ืขืœ ืžืชื’ื™ื ืงื™ืฆื•ื ื™ื™ื
  • ื”ื’ื“ืจืช ื”ื’ื“ืจื•ืช ืžืชื’ ืงื™ืฆื•ื ื™
  • ืกืงื•ืจ ื”ืฉื•ื•ืื” ืฉืœ ืžืชื’ื™ ืืงืกื˜ืจื™ื ืขื ืฆื™ื•ื“ ืฉืœ ืกืคืงื™ื ืื—ืจื™ื
  • ื—ื•ื–ื™ ืื—ืจื™ื•ืช, ืชืžื™ื›ื” ื˜ื›ื ื™ืช ื•ื—ื•ื–ื™ ืฉื™ืจื•ืช ืขื‘ื•ืจ ืžืชื’ื™ ืืงืกื˜ืจื™ื

ืื ื™ ืžื–ืžื™ืŸ ืืชื›ื ืœืงืจื•ื ืืช ืกื“ืจืช ื”ืžืืžืจื™ื ื”ื–ื• ืœื›ืœ ืžื™ ืฉืžืชืขื ื™ื™ืŸ ื‘ืกืคืง ื–ื”, ื•ืคืฉื•ื˜ ืœืžื”ื ื“ืกื™ ืจืฉืช ื•ืžื ื”ืœื™ ืจืฉืช ื”ืขื•ืžื“ื™ื ื‘ืคื ื™ ื‘ื—ื™ืจื” ืื• ื”ื’ื“ืจื” ืฉืœ ืžืชื’ื™ื ืืœื•.

ืื•ื“ื•ืชื™ื ื•

ืจืืฉื™ืช, ื‘ืจืฆื•ื ื™ ืœื”ืฆื™ื’ ื‘ืคื ื™ื›ื ืืช ื”ื—ื‘ืจื” ื•ืืช ื”ื”ื™ืกื˜ื•ืจื™ื” ืฉืœ ืžื•ืฆืื”:
ืจืฉืชื•ืช ืืงืกื˜ืจื™ื ื”ื™ื ื” ื—ื‘ืจืช ื˜ืœืงื•ืžื•ื ื™ืงืฆื™ื” ืฉื ื•ืกื“ื” ื‘ืฉื ืช 1996 ื‘ืžื˜ืจื” ืœืงื“ื ืคืชืจื•ื ื•ืช ืžืชืงื“ืžื™ื ื‘ื˜ื›ื ื•ืœื•ื’ื™ื™ืช Ethernet ื•ืคื™ืชื•ื— ืชืงืŸ Ethernet. ืชืงื ื™ Ethernet ืจื‘ื™ื ื‘ืชื—ื•ืžื™ ื”ืจื—ื‘ืช ื”ืจืฉืช, ืื™ื›ื•ืช ื”ืฉื™ืจื•ืช ื•ื”ืชืื•ืฉืฉื•ืช ื”ืžื”ื™ืจื” ื”ื ืคื˜ื ื˜ื™ื ืคืชื•ื—ื™ื ืฉืœ Extreme Networks. ื”ืžื˜ื” ืžืžื•ืงื ื‘ืกืŸ ื—ื•ื–ื” (ืงืœื™ืคื•ืจื ื™ื”), ืืจื”"ื‘. ื›ืจื’ืข, Extreme Networks ื”ื™ื ื—ื‘ืจื” ืฆื™ื‘ื•ืจื™ืช ื”ืžืชืžืงื“ืช ื‘ืžื™ื•ื—ื“ ื‘ืคื™ืชื•ื— ืฉืœ Ethernet.

ื ื›ื•ืŸ ืœื“ืฆืžื‘ืจ 2015 ืขืžื“ ืžืกืคืจ ื”ืขื•ื‘ื“ื™ื ืขืœ 1300 ืื™ืฉ.

ืืงืกื˜ืจื™ื ื ื˜ื•ื•ืจืงืก ืžืฆื™ืขื” ืคืชืจื•ื ื•ืช ืจืฉืช ืงื•ื•ื™ืช ื•ืืœื—ื•ื˜ื™ืช ื”ืขื•ื ื™ื ืขืœ ื”ื“ืจื™ืฉื•ืช ืฉืœ ืขื•ืœื ื”ืžื•ื‘ื™ื™ืœ ืฉืœ ื”ื™ื•ื, ืขื ืชื ื•ืขื” ืžืชืžื“ืช ืฉืœ ืžืฉืชืžืฉื™ื ื•ืžื›ืฉื™ืจื™ื, ื›ืžื• ื’ื ื”ื’ื™ืจื” ืฉืœ ืžื›ื•ื ื•ืช ื•ื™ืจื˜ื•ืืœื™ื•ืช ื”ืŸ ื‘ืชื•ืš ืžืจื›ื– ื”ื ืชื•ื ื™ื ื•ื”ืŸ ืžื—ื•ืฆื” ืœื• - ืœืขื ืŸ. ื‘ืืžืฆืขื•ืช ืžืขืจื›ืช ื”ืคืขืœื” ืื—ืช, ExtremeXOS ืžืืคืฉืจืช ืœื™ืฆื•ืจ ืคืชืจื•ื ื•ืช ืžืชืงื“ืžื™ื ื”ืŸ ืœืžืคืขื™ืœื™ ื˜ืœืงื•ื ื•ื”ืŸ ืœืจืฉืชื•ืช ืžืจื›ื–ื™ ื ืชื•ื ื™ื, ื•ื”ืŸ ืœืจืฉืชื•ืช ืžืงื•ืžื™ื•ืช/ืงืžืคื•ืกื™ื.

ืฉื•ืชืคื™ ื—ื‘ืจื” ื‘ื—ื‘ืจ ื”ืขืžื™ื

  • ื‘ืจื•ืกื™ื”, ืœ-Extreme Networks ื™ืฉ ืฉืœื•ืฉื” ืžืคื™ืฆื™ื ืจืฉืžื™ื™ื - RRC, Marvel ื•-OCS, ื›ืžื• ื’ื ื™ื•ืชืจ ืž-100 ืฉื•ืชืคื™ื, ืฉืžืกืคืจื ื’ื“ืœ ืœืœื ื”ืจืฃ.
  • ื‘ื‘ืœืืจื•ืก, ืœ-Extreme Networks ื™ืฉ ืฉืœื•ืฉื” ืžืคื™ืฆื™ื ืจืฉืžื™ื™ื - Solidex, MUK ื•-Abris. ืœื—ื‘ืจืช Solidex ื™ืฉ ืžืขืžื“ ืฉืœ ืฉื•ืชืฃ ื”ื“ืจื›ื” ืžื•ืจืฉื”.
  • ื‘ืื•ืงืจืื™ื ื” ื™ืฉ ืžืคื™ืฅ ืจืฉืžื™ ืื—ื“ - "Informatsiyne Merezhivo".
  • ื‘ืžื“ื™ื ื•ืช ืžืจื›ื– ืืกื™ื”, ื›ืžื• ื’ื ื‘ื’ืจื•ื–ื™ื”, ืืจืžื ื™ื” ื•ืื–ืจื‘ื™ื™ื’'ืŸ, ื”ืžืคื™ืฆื™ื ื”ืจืฉืžื™ื™ื ื”ื RRC ื•ืื‘ืจื™ืก.

ื•ื‘ื›ืŸ, ื ืคื’ืฉื ื•, ื•ืขื›ืฉื™ื• ื‘ื•ืื• ื ืจืื” ืื™ืœื• ืžืชื’ื™ื ื”ืกืคืง ื”ื–ื” ื™ื›ื•ืœ ืœื”ืฆื™ืข ืœื ื• ืขื‘ื•ืจ ื”ืจืฉืช ื”ืืจื’ื•ื ื™ืช ืฉืœื ื•.

ื•ื”ื•ื ื™ื›ื•ืœ ืœื”ืฆื™ืข ืœื ื• ืืช ื”ื“ื‘ืจื™ื ื”ื‘ืื™ื:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื”ืื™ื•ืจ ืฉืœืžืขืœื” ืžืฆื™ื’ ื“ื’ืžื™ ืžืชื’ื™ื ื‘ื”ืชืื ืœืกื•ื’ ืžืขืจื›ืช ื”ื”ืคืขืœื” ื”ืฉื•ืœื˜ืช ื‘ืžืชื’ื™ื ื•ื‘ื˜ื›ื ื•ืœื•ื’ื™ื•ืช ื”ื ืชืžื›ื•ืช ืขืœ ื™ื“ื™ ื”ื™ืฆื™ืื•ืช (ื—ืฅ ืื ื›ื™ ืžืฉืžืืœ):

  • 1 Gigabit Ethernet
  • 10 Gigabit Ethernet
  • 40 Gigabit Ethernet
  • 100 Gigabit Ethernet

ื‘ื•ืื• ื ืกืชื›ืœ ืžืงืจื•ื‘ ืขืœ ืžืชื’ื™ ื”-Extreme, ื”ื—ืœ ืžืกื“ืจืช V400.

ืžืชื’ื™ื ืžืกื“ืจืช V400

ืืœื• ื”ื ืžืชื’ื™ื ื”ืžืฉืชืžืฉื™ื ื‘ื˜ื›ื ื•ืœื•ื’ื™ื™ืช Virtual Port Extending (ืžื‘ื•ืกืก ืขืœ ืžืคืจื˜ IEE 802.1BR). ื”ืžืชื’ื™ื ืขืฆืžื ื ืงืจืื™ื ืžืจื—ื™ื‘ื™ ื™ืฆื™ืื•ืช ื•ื™ืจื•ืืœื™ื.

ื”ืžื”ื•ืช ืฉืœ ื˜ื›ื ื•ืœื•ื’ื™ื” ื–ื• ื”ื™ื ืฉื›ืœ ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ื”ื‘ืงืจื” ื•ื”-dataplane ืžื•ืขื‘ืจืช ืžื”ืžืชื’ ืขืฆืžื• ืœืžืชื’ื™ ืฆื‘ื™ืจื” - Controller Bridges/CB.

ืจืง ืžืชื’ื™ื ืžื”ื“ื’ืžื™ื ื”ื‘ืื™ื ื™ื›ื•ืœื™ื ืœืฉืžืฉ ื›ืžืชื’ Controller Bridge:

  • x590
  • x670-G2
  • x620-G2

ืœืคื ื™ ืชื™ืื•ืจ ืžืขื’ืœื™ื ื˜ื™ืคื•ืกื™ื™ื ืœื—ื™ื‘ื•ืจ ืžืชื’ื™ื ืืœื”, ืืชืืจ ืืช ื”ืžืคืจื˜ ืฉืœื”ื:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื›ืคื™ ืฉื ื™ืชืŸ ืœืจืื•ืช ืžื”ื˜ื‘ืœื” ืฉืœืžืขืœื”, ืœืžืชื’ื™ื, ื‘ื”ืชืื ืœืžืกืคืจ ื™ืฆื™ืื•ืช ื”ื’ื™ืฉื” ืฉืœ GE (24 ืื• 48), ื™ืฉ 2 ืื• 4 ื™ืฆื™ืื•ืช 10GE SFP+ uplink.

ื™ืฉื ื ื’ื ืžืชื’ื™ื ืขื ื™ืฆื™ืื•ืช PoE ืœื—ื™ื‘ื•ืจ ื•ื”ืคืขืœืช ื”ืชืงื ื™ PoE ื‘ืืžืฆืขื•ืช ื˜ื›ื ื•ืœื•ื’ื™ื•ืช 802.3af (ืขื“ 15 W ืœื™ืฆื™ืื”) ื•-802.3at (ืขื“ 30 W ืœื™ืฆื™ืื”).

ืœื”ืœืŸ 4 ื“ื™ืื’ืจืžื•ืช ื—ื™ื‘ื•ืจ ืื•ืคื™ื™ื ื™ื•ืช ืขื‘ื•ืจ ืžืชื’ื™ V400 ื•-CB:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื”ื™ืชืจื•ื ื•ืช ืฉืœ ื˜ื›ื ื•ืœื•ื’ื™ื™ืช ื”ืจื—ื‘ืช ื ืžืœ ื•ื™ืจื˜ื•ืืœื™:

  • ืงืœื•ืช ืชื—ื–ื•ืงื” - ืื ืื—ื“ ืžืžืชื’ื™ ื”-V400 ื ื›ืฉืœ, ื™ืกืคื™ืง ืคืฉื•ื˜ ืœื”ื—ืœื™ืฃ ืื•ืชื• ื•ื”ืžืชื’ ื”ื—ื“ืฉ ื™ื–ื•ื”ื” ืื•ื˜ื•ืžื˜ื™ืช ื•ื™ื•ื’ื“ืจ ืœืคืขื•ืœืช CB. ื–ื” ืžื‘ื˜ืœ ืืช ื”ืฆื•ืจืš ืœื”ื’ื“ื™ืจ ื›ืœ ืžืชื’ ื’ื™ืฉื”
  • ื›ืœ ื”ืชืฆื•ืจื” ืžืžื•ืงืžืช ืจืง ื‘-CB, ืžืชื’ื™ V400 ื ืจืื™ื ืจืง ื›ื™ืฆื™ืื•ืช CB ื ื•ืกืคื•ืช, ืžื” ืฉืžืคืฉื˜ ืืช ื”ื ื™ื”ื•ืœ ืฉืœ ืžืชื’ื™ื ืืœื”
  • ื›ืืฉืจ ื ืขืฉื” ืฉื™ืžื•ืฉ ื‘-V400 ื‘ืฉื™ืœื•ื‘ ืขื Controller Bridge, ืืชื” ืžืงื‘ืœ ืืช ื›ืœ ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืฉืœ Controller Bridge ืขืœ ืžืชื’ื™ V400

ื”ื’ื‘ืœื” ื˜ื›ื ื•ืœื•ื’ื™ืช - ื ืชืžื›ื™ื ืขื“ 48 ืžืืจื—ื™ ื™ืฆื™ืื•ืช ืฉืœ ืžืชื’ื™ V400 (2300 ื™ืฆื™ืื•ืช ื’ื™ืฉื”).

ืžืชื’ื™ื ืžืกื“ืจืช X210 ื•-X220

ืœืžืชื’ื™ื ืžืžืฉืคื—ืช E200 ื™ืฉ ืžืกืคืจ ืงื‘ื•ืข ืฉืœ 10/100/1000 ื™ืฆื™ืื•ืช BASE-T, ืคื•ืขืœื™ื ื‘ืจืžื•ืช L2/L3 ื•ืžื™ื•ืขื“ื™ื ืœืฉื™ืžื•ืฉ ื›ืžืชื’ื™ ื’ื™ืฉื” ืœืืจื’ื•ื ื™ื. ื‘ื”ืชืื ืœื“ื’ื, ืœืžืชื’ื™ื ื™ืฉ:

  • ื™ืฆื™ืื•ืช PoE/PoE+
  • 2 ืื• 4 ื™ื—ื™ื“ื•ืช 10 ื™ืฆื™ืื•ืช GE SFP+ (ืกื“ืจืช X220)
  • ืชืžื™ื›ื” ื‘ืขืจื™ืžื” - ืขื“ 4 ืžืชื’ื™ื ื‘ืขืจื™ืžื” (ืกื“ืจืช X220)

ืœื”ืœืŸ ืืกืคืง ื˜ื‘ืœื” ืขื ื”ืชืฆื•ืจื” ื•ื›ืžื” ื™ื›ื•ืœื•ืช ืฉืœ ื”ืžืชื’ื™ื ืžืกื“ืจืช X200

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื›ืคื™ ืฉื ื™ืชืŸ ืœืจืื•ืช ืžื”ื˜ื‘ืœื”, ื”ืžืชื’ื™ื ืžืกื“ืจื•ืช E210 ื•-E220 ืžื™ื•ืขื“ื™ื ืœืฉื™ืžื•ืฉ ื›ืžืชื’ื™ ื’ื™ืฉื”. ื”ื•ื“ื•ืช ืœื ื•ื›ื—ื•ืช ืฉืœ 10 ื™ืฆื™ืื•ืช GE SFP+, ื”ืžืชื’ื™ื ืžืกื“ืจืช X220 ื™ื›ื•ืœื™ื ืœืชืžื•ืš ื‘ืขืจื™ืžื” - ืขื“ 4 ื™ื—ื™ื“ื•ืช ืœื›ืœ ืžื—ืกื ื™ืช, ืขื ืจื•ื—ื‘ ืคืก ืžื—ืกื ื™ืช ืฉืœ 40 ื’'ื™ื’ื”-ื‘ื™ื™ื˜.

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื”ืžืชื’ื™ื ืžื ื•ื”ืœื™ื ืขืœ ื™ื“ื™ ืžืขืจื›ืช ื”ื”ืคืขืœื” EOS.

ืžืชื’ื™ื ืžืกื“ืจืช ERS

ืžืชื’ื™ื ืžืกื“ืจื” ื–ื• ืคืจื•ื“ื•ืงื˜ื™ื‘ื™ื™ื ื™ื•ืชืจ ื‘ื”ืฉื•ื•ืื” ืœืžืชื’ื™ื ืžืกื“ืจืช E200 ื”ืฆืขื™ืจื” ื™ื•ืชืจ.

ืงื•ื“ื ื›ืœ, ื›ื“ืื™ ืœืฉื™ื ืœื‘:

  • ืœืžืชื’ื™ื ื”ืืœื” ื™ืฉ ื™ื›ื•ืœื•ืช ืขืจื™ืžื” ืžืชืงื“ืžื•ืช ื™ื•ืชืจ:
    • ืขื“ 8 ืžืชื’ื™ื ื‘ืขืจื™ืžื”
    • ื‘ื”ืชืื ืœื“ื’ื, ื ื™ืชืŸ ืœื”ืฉืชืžืฉ ื’ื ื‘ื™ืฆื™ืื•ืช SFP+ ื•ื’ื ื‘ื™ืฆื™ืื•ืช ื™ื™ืขื•ื“ื™ื•ืช ืœืขืจืžื”

  • ืœืžืชื’ื™ื ืžืกื“ืจืช ERS ื™ืฉ ืชืงืฆื™ื‘ PoE ื’ื“ื•ืœ ื™ื•ืชืจ ื‘ื”ืฉื•ื•ืื” ืœืกื“ืจืช E200
  • ืœืžืชื’ื™ื ืžืกื“ืจืช ERS ื™ืฉ ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช L3 ืจื—ื‘ื” ื™ื•ืชืจ ื‘ื”ืฉื•ื•ืื” ืœืกื“ืจืช E200

ืื ื™ ืžืฆื™ืข ืœื”ืชื—ื™ืœ ืกืงื™ืจื” ืžืคื•ืจื˜ืช ื™ื•ืชืจ ืฉืœ ืžืฉืคื—ืช ื”ืžืชื’ื™ื ืฉืœ ERS ืขื ืงื• ื”ื’'ื•ื ื™ื•ืจ - ERS3600.

ืกื“ืจืช ERS3600

ืžืชื’ื™ื ื‘ืกื“ืจื” ื–ื• ืžื•ืฆื’ื™ื ื‘ืชืฆื•ืจื•ืช ื”ื‘ืื•ืช:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื›ืคื™ ืฉื ื™ืชืŸ ืœืจืื•ืช ืžื”ื˜ื‘ืœื”, ืžืชื’ื™ ERS 3600 ื™ื›ื•ืœื™ื ืœืฉืžืฉ ื›ืžืชื’ื™ ื’ื™ืฉื”, ื‘ืขืœื™ ืงื™ื‘ื•ืœืช ืžื—ืกื ื™ืช ื’ื“ื•ืœื” ื™ื•ืชืจ, ืชืงืฆื™ื‘ PoE ื’ื“ื•ืœ ื™ื•ืชืจ ื•ืžื’ื•ื•ืŸ ืจื—ื‘ ื™ื•ืชืจ ืฉืœ ืคื•ื ืงืฆื™ื•ืช L3, ืื ื›ื™ ื›ืžื•ื‘ืŸ ื”ื ืžื•ื’ื‘ืœื™ื ืจืง ืขืœ ื™ื“ื™ ื ื™ืชื•ื‘ ื“ื™ื ืžื™ RIP v1/v2 ืคืจื•ื˜ื•ืงื•ืœื™ื, ื›ืžื• ื’ื ืžืกืคืจ ื”ืžืžืฉืงื™ื ื•ื”ืžืกืœื•ืœื™ื ื”ืžืขื•ืจื‘ื™ื ื‘ื’ืจืžื ื™ืช

ื”ืชืžื•ื ื” ืœืžื˜ื” ืžืฆื™ื’ื” ืืช ื”ืžื‘ื˜ ื”ืงื“ืžื™ ื•ื”ืื—ื•ืจื™ ืฉืœ ืžืชื’ ERS50 ืขื 3600 ื™ืฆื™ืื•ืช:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืกื“ืจืช ERS4900

ื ื™ืชืŸ ืœืชืืจ ื‘ืงืฆืจื” ืืช ื”ืชืฆื•ืจื” ื•ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืฉืœ ืžืชื’ื™ ืกื“ืจืช ERS4900 ื‘ื˜ื‘ืœื” ื”ื‘ืื”:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื›ืคื™ ืฉืื ื• ื™ื›ื•ืœื™ื ืœืจืื•ืช, ืžืชื’ื™ื ืืœื• ืžื™ื™ืฉืžื™ื ืคืจื•ื˜ื•ืงื•ืœื™ ื ื™ืชื•ื‘ ื“ื™ื ืžื™ื™ื, ื›ื’ื•ืŸ RIPv1/2 ื•-OSPF, ืงื™ื™ื ืคืจื•ื˜ื•ืงื•ืœ ื™ืชื™ืจื•ืช ืฉืขืจ - VRRP, ื•ื’ื ืชืžื™ื›ื” ื‘ืคืจื•ื˜ื•ืงื•ืœ IPv6.

ื›ืืŸ ืื ื™ ื—ื™ื™ื‘ ืœืฆื™ื™ืŸ ื”ืขืจื” ื—ืฉื•ื‘ื” -* ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ื ื•ืกืคืช ืฉืœ L2 ื•-L3 (OSPF, VRRP, ECMP, PIM-SM, PIMSSM/PIM-SSM, IPv6 Routing) ืžื•ืคืขืœืช ืขืœ ื™ื“ื™ ืจื›ื™ืฉืช ืจื™ืฉื™ื•ืŸ ื ื•ืกืฃ - Advanced Software License.

ื”ืชืžื•ื ื•ืช ืœืžื˜ื” ืžืฆื™ื’ื•ืช ืืช ื”ืžื‘ื˜ ื”ืงื“ืžื™ ื•ื”ืื—ื•ืจื™ ืฉืœ ืžืชื’ ERS26 ืขื 4900 ื™ืฆื™ืื•ืช ื•ืืช ื”ืืคืฉืจื•ืช ืœืขืจื•ื ืื•ืชื:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื›ืคื™ ืฉื ื™ืชืŸ ืœืจืื•ืช ืžื”ืชืžื•ื ื•ืช, ืœืžืชื’ื™ื ืžืกื“ืจืช ERS4900 ื™ืฉ ื™ืฆื™ืื•ืช ื™ื™ืขื•ื“ื™ื•ืช ืœืขืจื•ื - Cascade UP/Cascade Down, ื•ื ื™ืชืŸ ืœืฆื™ื™ื“ ืื•ืชื ื’ื ื‘ืกืคืงื™ ื›ื•ื— ืžื™ื•ืชืจื™ื.

ืกื“ืจืช ERS5900

ื”ื“ื’ืžื™ื ื”ืขื“ื›ื ื™ื™ื ื•ื”ื‘ื›ื™ืจื™ื ื‘ื™ื•ืชืจ ื‘ืกื“ืจืช ERS ื”ื ืžืชื’ื™ ื”-ERS5900.

ืžืชื•ืš ืžืขื ื™ื™ืŸ:

  • ื—ืœืง ืžื”ืžืชื’ื™ื ื‘ืกื“ืจื” ื›ื•ืœืœื™ื Universal PoE - ื”ื™ื›ื•ืœืช ืœื”ืคื™ืง 60 W ืœื›ืœ ื™ืฆื™ืื” ื›ื“ื™ ืœื”ืคืขื™ืœ ืžื›ืฉื™ืจื™ื ืžื™ื•ื—ื“ื™ื ื•ืžืชื’ื™ื/ื ืชื‘ื™ื ืงื˜ื ื™ื
  • ื™ืฉ ืœื ื• 100 ืžืชื’ื™ ื™ืฆื™ืื•ืช ืขื ืชืงืฆื™ื‘ PoE ื›ื•ืœืœ ืฉืœ 2,8 ืงื™ืœื•ื•ืื˜
  • ื™ืฉ ื™ืฆื™ืื•ืช ื”ืชื•ืžื›ื•ืช ื‘-2.5GBASE-T (ืชืงืŸ 802.3bz)
  • ืชืžื™ื›ื” ื‘ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช MACsec (ืชืงืŸ 802.1AE)

ื”ืชืฆื•ืจื•ืช ื•ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืฉืœ ืžืชื’ื™ ื”ืกื“ืจื” ืžืชื•ืืจื™ื ื‘ืฆื•ืจื” ื”ื˜ื•ื‘ื” ื‘ื™ื•ืชืจ ื‘ื˜ื‘ืœื” ื”ื‘ืื”:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

* ืžืชื’ื™ 5928GTS-uPWR ื•-5928MTS-uPWR ืชื•ืžื›ื™ื ื‘ื™ื•ื–ืžืช Four-Pair PoE (ื”ืžื›ื•ื ื” Universal PoE - uPoE) - ื”ื™ื›ื•ืœืช ืœื”ืคืขื™ืœ ืžื›ืฉื™ืจื™ื ืขื ืฆืจื™ื›ื” ืฉืœ ืขื“ 60 W ื‘ื™ืฆื™ืืช ื”ื’ื™ืฉื”, ืœืžืฉืœ, ื—ืœืง ืกื•ื’ื™ ืžืขืจื›ื•ืช ืชืงืฉื•ืจืช ื•ื™ื“ืื•, ืœืงื•ื—ื•ืช ื“ืงื™ื VDI ืขื ืฆื’ื™ื, ืžืชื’ื™ื ืงื˜ื ื™ื ืื• ื ืชื‘ื™ื ืขื ื›ื•ื— PoE ื•ืืคื™ืœื• ื›ืžื” ืžืขืจื›ื•ืช ื˜ื›ื ื•ืœื•ื’ื™ื•ืช IoT (ืœื“ื•ื’ืžื”, ืžืขืจื›ื•ืช ื‘ืงืจืช ืชืื•ืจื” ื—ื›ืžื•ืช).
** ืชืงืฆื™ื‘ PoE ืฉืœ 1440 W ืžื•ืฉื’ ื‘ืขืช ื”ืชืงื ืช 2 ืกืคืงื™ ื›ื•ื—. ื‘ืขืช ื”ืชืงื ืช ืกืคืง ื›ื•ื— ืื—ื“ ืœืžืชื’, ืชืงืฆื™ื‘ ื”-PoE ื™ื”ื™ื” 1 W.
*** ืชืงืฆื™ื‘ PoE ืฉืœ 2880 W ืžื•ืฉื’ ื‘ื”ืชืงื ืช 4 ืกืคืงื™ ื›ื•ื—. ื‘ืขืช ื”ืชืงื ืช ืกืคืง ื›ื•ื— ืื—ื“ ืœืžืชื’, ืชืงืฆื™ื‘ ื”-PoE ื™ื”ื™ื” 1 W. ื‘ืขืช ื”ืชืงื ืช 1200 ืกืคืงื™ ื›ื•ื— ื‘ืžืชื’, ืชืงืฆื™ื‘ ื”-PoE ื™ื”ื™ื” 2 W.

ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ื ื•ืกืคืช ืฉืœ L2 ื•-L3, ื›ืžื• ื‘ืžืงืจื” ืฉืœ ืกื“ืจืช ERS4900, ื ื™ืชื ืช ืขืœ ื™ื“ื™ ืจื›ื™ืฉื” ื•ื”ืคืขืœื” ืฉืœ ื”ืจื™ืฉื™ื•ื ื•ืช ื”ืžืชืื™ืžื™ื ืœืžืชื’ื™ื:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื”ืชืžื•ื ื•ืช ืœืžื˜ื” ืžืฆื™ื’ื•ืช ืืช ื”ืžื‘ื˜ ื”ืงื“ืžื™ ื•ื”ืื—ื•ืจื™ ืฉืœ ืžืชื’ ERS100 ืขื 5900 ื™ืฆื™ืื•ืช ื•ืืช ืืคืฉืจื•ืช ื”ืขืจื™ืžื” ืฉืœ ืžืชื’ื™ 28 ื•-52 ื™ืฆื™ืื•ืช:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

**ื›ืœ ืžืชื’ื™ ื”ืกื“ืจื” ืžื ื•ื”ืœื™ื ืขืœ ื™ื“ื™ ืžืขืจื›ืช ื”ื”ืคืขืœื” ERS.**

ื—ื‘ืจื™ื, ื›ืคื™ ืฉื‘ื˜ื— ืฉืžืชื ืœื‘, ื‘ืกื•ืฃ ืชื™ืื•ืจ ื”ืกื“ืจื” ืื ื™ ืžืฆื™ื™ืŸ ื‘ืื™ื–ื• ืžืขืจื›ืช ื”ืคืขืœื” ื”ื ื ืฉืœื˜ื™ื, ืื– - ืื ื™ ืขื•ืฉื” ื–ืืช ืžืกื™ื‘ื” ื›ืœืฉื”ื™. ื›ืคื™ ืฉืจื‘ื™ื ื›ื‘ืจ ื ื™ื—ืฉื•, ื”ืขื•ื‘ื“ื” ื”ื™ื ืฉื ื™ื”ื•ืœ ืžืขืจื›ืช ื”ืคืขืœื” ืžืกื•ื™ืžืช ืคื™ืจื•ืฉื• ืกื˜ ืื™ื ื“ื™ื‘ื™ื“ื•ืืœื™ ืฉืœ ืคืงื•ื“ื•ืช ืชื—ื‘ื™ืจ ื•ื‘ืœื•ืงื™ ื”ื’ื“ืจื•ืช ืขื‘ื•ืจ ื›ืœ ืžืขืจื›ืช ื”ืคืขืœื”.

ืœื“ื•ื’ืžื”:
ื›ืคื™ ืฉื•ื•ื“ืื™ ืฉืžื• ืœื‘ ื—ื•ื‘ื‘ื™ ืžืชื’ื™ Avaya, ื‘ืชื™ืื•ืจ ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืฉืœ ื”-L2 ืฉืœ ื”ืžืชื’ื™ื ืžืกื“ืจืช ERS ื™ืฉ ืฉื•ืจื” MLT/LACP Groups, ื”ืžืืคื™ื™ื ืช ืืช ื”ืžืกืคืจ ื”ืžืงืกื™ืžืœื™ ื”ืืคืฉืจื™ ืฉืœ ืงื‘ื•ืฆื•ืช ืœืฉื™ืœื•ื‘ ืžืžืฉืงื™ื ืœืชื•ื›ื (ืฆื‘ื™ืจื” ื•ื™ืชื™ืจื•ืช ืฉืœ ืงื™ืฉื•ืจื™ ืชืงืฉื•ืจืช ). ื™ื™ืขื•ื“ ื”-MLT ื”ื•ื ืกืคืฆื™ืคื™ ืœืฆื‘ื™ืจื” ืฉืœ ืงื™ืฉื•ืจื™ื ื‘ืžืชื’ื™ื ื”ืžื™ื•ืฆืจื™ื ืขืœ ื™ื“ื™ Avaya Holding, ื›ืืฉืจ ื”ื•ื ืžืฉืžืฉ ื™ืฉื™ืจื•ืช ื‘ืชื—ื‘ื™ืจ ื”ืคืงื•ื“ื” ื‘ืขืช ื”ื’ื“ืจืช ืฆื‘ื™ืจืช ืงื™ืฉื•ืจ.

ื”ืขื ื™ื™ืŸ ื”ื•ื ืฉ-ExtremeNetworks, ื‘ื”ืชืื ืœืืกื˜ืจื˜ื’ื™ื™ืช ื”ืคื™ืชื•ื— ืฉืœื”, ืจื›ืฉื” ืืช Avaya Holdings ื‘ืฉื ื™ื 2017-2018, ืฉื‘ืื•ืชื” ืชืงื•ืคื” ื”ื™ื™ืชื” ืœื” ืงื• ืžืชื’ื™ื ืžืฉืœื”. ืœืคื™ื›ืš, ืกื“ืจืช ื”-ERS ื”ื™ื ื‘ืขืฆื ื”ืžืฉืš ืฉืœ ืงื• ื”ืžืชื’ื™ื ืฉืœ Avaya.

ืžืชื’ื™ื ืžืกื“ืจืช EXOS

ืกื“ืจืช EXOS ื ื—ืฉื‘ืช ืœืกื“ืจืช ื”ืืงืกื˜ืจื™ื "ืกืคื™ื ืช ื”ื“ื’ืœ". ื”ืžืชื’ื™ื ืฉืœ ืงื• ื–ื” ืžื™ื™ืฉืžื™ื ืืช ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ื”ื—ื–ืงื” ื‘ื™ื•ืชืจ - ื”ืŸ ืคืจื•ื˜ื•ืงื•ืœื™ื ืกื˜ื ื“ืจื˜ื™ื™ื ืจื‘ื™ื ื•ื”ืŸ ืคืจื•ื˜ื•ืงื•ืœื™ Extreme ืจื‘ื™ื "ืฉืœื”ื", ืื•ืชื ืื ืกื” ืœืชืืจ ื‘ืขืชื™ื“.

ื‘ื• ืชื•ื›ืœื• ืœืžืฆื•ื ืžืชื’ื™ื ืœื›ืœ ื˜ืขื:

  • ืœื›ืœ ืจืžืช ืจืฉืช - ื’ื™ืฉื”, ืฆื‘ื™ืจื”, ืœื™ื‘ื”, ืžืชื’ื™ื ืœืžืจื›ื–ื™ ื ืชื•ื ื™ื
  • ืขื ื›ืœ ืกื˜ ืฉืœ ื™ืฆื™ืื•ืช 10/100/1000 Base-T, SFP, SFP+, QSFP, QSFP+
  • ืขื ืื• ื‘ืœื™ ืชืžื™ื›ืช PoE
  • ืขื ืชืžื™ื›ื” ื‘ืžืกืคืจ ืกื•ื’ื™ื ืฉืœ "ืขืจื™ืžื”" ื•ืชืžื™ื›ื” ื‘"ืืฉื›ื•ืœ" ื›ื“ื™ ืœื”ื‘ื˜ื™ื— ืกื•ื‘ืœื ื•ืช ืชืงืœื•ืช ืฉืœ ืฆืžืชื™ ืจืฉืช ืงืจื™ื˜ื™ื™ื

ืœืคื ื™ ืชื—ื™ืœืช ื”ืกืงื™ืจื” ืฉืœื ื• ืขืœ ืกื“ืจื” ื–ื• ืขื ื”ืงื• ื”ืฆืขื™ืจ ื‘ื™ื•ืชืจ - X440, ื‘ืจืฆื•ื ื™ ืœื”ืกื‘ื™ืจ ืืช ืžื“ื™ื ื™ื•ืช ื”ืจื™ืฉื•ื™ ืขื‘ื•ืจ ืžืขืจื›ืช ื”ื”ืคืขืœื” EXOS.

ืจื™ืฉื•ื™ EXOS (ื”ื—ืœ ืžื’ืจืกื” 22.1)

ืœ-EXOS ื™ืฉ 3 ืกื•ื’ื™ ืจื™ืฉื™ื•ื ื•ืช ืขื™ืงืจื™ื™ื - ืจื™ืฉื™ื•ืŸ Edge, ืจื™ืฉื™ื•ืŸ ืื“ื’' ืžืชืงื“ื, ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”.
ื”ื˜ื‘ืœื” ืฉืœื”ืœืŸ ืžืชืืจืช โ€‹โ€‹ืืคืฉืจื•ื™ื•ืช ืฉื™ืžื•ืฉ ื‘ืจื™ืฉื™ื•ื ื•ืช ื‘ื”ืชืื ืœืงื•ื•ื™ ื”ืžืชื’ื™ื ืžืกื“ืจืช EXOS:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

  • Standard ื”ื™ื ื’ืจืกืช EXOS ืฉืœ ืžืขืจื›ืช ื”ื”ืคืขืœื” ืฉืžื’ื™ืขื” ื›ืกื˜ื ื“ืจื˜ ืขื ื”ืžืชื’
  • ืฉื“ืจื•ื’ ื”ื•ื ื”ื™ื›ื•ืœืช ืœื”ืจื—ื™ื‘ ืืช ืžืขืจื›ืช ื”ื”ืคืขืœื” EXOS ืœื›ืœ ืจืžื”.

ื ื™ืชืŸ ืœืจืื•ืช ืืช ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืฉืœ ื›ืœ ืกื•ื’ ืจื™ืฉื™ื•ืŸ ื•ื”ืชืžื™ื›ื” ื‘ื• ื‘ืคืœื˜ืคื•ืจืžื•ืช ื”ืฉื•ื ื•ืช ื‘ืกื“ืจื” ื‘ื˜ื‘ืœืื•ืช ืœืžื˜ื”.

ืจื™ืฉื™ื•ืŸ ืื“ื’'

ืชื›ื•ื ืช ืชื•ื›ื ืช ExtremeXOS
ืคืœื˜ืคื•ืจืžื•ืช ื ืชืžื›ื•ืช

EDP
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื™ืช ืจืฉืช ืงื™ืฆื•ื ื™ืช (XNV)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ื™ื”ื•ืœ ื–ื”ื•ืช
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

LLDP 802.1ab
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื”ืจื—ื‘ื•ืช LLDP-MED
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืจืฉืชื•ืช VLAN - ื˜ืจืื ืงื™ื ืžื‘ื•ืกืกื™ ื™ืฆื™ืื•ืช ื•ืžืชื•ื™ื’ื™ื
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืจืฉืชื•ืช VLAN - ืžื‘ื•ืกืกื•ืช MAC
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืจืฉืชื•ืช VLAN - ืžื‘ื•ืกืกื•ืช ืคืจื•ื˜ื•ืงื•ืœ
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืจืฉืชื•ืช VLAN - ืจืฉืชื•ืช VLAN ืคืจื˜ื™ื•ืช
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

VLANsโ€”ืชืจื’ื•ื VLAN
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

VMANs โ€” ืžื ื”ื•ืจ Q-in-Q (ืชืงืŸ ืžื ื”ื•ืจ IEEE 802.1ad VMAN)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

VMANs - ื‘ื—ื™ืจืช ืชื•ืจ ื™ืฆื™ืื” ืขืœ ืกืžืš ืขืจืš 802.1p ื‘-S-tag
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

VMANs - ื‘ื—ื™ืจืช ืชื•ืจ ื™ืฆื™ืื” ืขืœ ืกืžืš ืขืจืš 802.1p ื‘-C-tag
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

VMANs - ืชืžื™ื›ื” ื‘ืืชืจื˜ื™ื™ืค ืžืฉื ื™
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

VMAN Customer Edge Port (CEPโ€”ื™ื“ื•ืข ื’ื ื‘ืฉื Selective Q-in-Q)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

VMAN Customer Edge Port ืกื™ื ื•ืŸ ื™ืฆื™ืื•ืช CVID / ืชืจื’ื•ื CVID
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

VMANโ€”ื™ืฆื™ืืช CNP
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

VMANโ€”ื™ืฆื™ืืช CNP, ืชืžื™ื›ื” ื‘ืชื’ ื›ืคื•ืœ
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

VMANโ€”ื™ืฆื™ืืช CNP, ืชื’ ื›ืคื•ืœ ืขื ืกื™ื ื•ืŸ ื™ืฆื™ืื•ืช
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

L2 Ping / Traceroute 802.1ag
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืžืกื’ืจื•ืช ื’'ืžื‘ื• (ื›ื•ืœืœ ื›ืœ ื”ืคืจื™ื˜ื™ื ื”ืงืฉื•ืจื™ื, ื“ื™ืกืง MTU. ืฉื‘ืจื™ IP)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

QoS - ืขื™ืฆื•ื‘/ื”ื’ื‘ืœืช ืงืฆื‘ ื™ืฆื™ืื”
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

QoS - ืขื™ืฆื•ื‘/ื”ื’ื‘ืœืช ืงืฆื‘ ื™ืฆื™ืื” ื‘ืชื•ืจ
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

Link Aggregation Groups (LAG), ืกื˜ื˜ื™ 802.3ad
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืงืฆื” ื“ื™ื ืžื™ ืฉืœ LAG (802.3ad LACP), ืœืฉืจืชื™ื ื‘ืœื‘ื“!
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืœื™ื‘ืช LAG (802.3ad LACP), ื‘ื™ืŸ ืžืชื’ื™ื
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื–ื™ื”ื•ื™ ื•ื›ื™ื‘ื•ื™ ืฉืœ ืœื•ืœืื” ืฉืœ ื™ืฆื™ืื” (ELRP CLI)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื™ืฆื™ืืช ืชื•ื›ื ื” ืžื™ื•ืชืจืช
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

STP 802.1D
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืžืฆื‘ ืชืื™ืžื•ืช STP EMISTP + PVST+ (ื“ื•ืžื™ื™ืŸ ืื—ื“ ืœื›ืœ ื™ืฆื™ืื”)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

STP EMISTP, PVST+ ืžืœื (ืชืžื™ื›ื” ื‘ืจื™ื‘ื•ื™ ื“ื•ืžื™ื™ื ื™ื)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

STP 802.1s
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

STP 802.1w
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ERPS (4 ื˜ื‘ืขื•ืช ืžืงืกื™ืžื•ื ืขื ื™ืฆื™ืื•ืช ื˜ื‘ืขื•ืช ืชื•ืืžื•ืช)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ESRP ืžื•ื“ืข
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

EAPS edge (4 ื“ื•ืžื™ื™ื ื™ื ืžืงืกื™ืžื•ื ืขื ื™ืฆื™ืื•ืช ื˜ื‘ืขืช ืชื•ืืžื•ืช)
ื”ืขืจื”: ื ื™ืชืŸ ืœื”ื’ื“ื™ืœ ืืช ืžืกืคืจ ื”ื“ื•ืžื™ื™ื ื™ื ืขืœ ื™ื“ื™ ืฉื“ืจื•ื’ ืœืจื™ืฉื™ื•ืŸ Advanced Edge (ืจืื” Advanced Edge License)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืื™ืชื•ืช ืชืงืœื•ืช ืงื™ืฉื•ืจ (LFS)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ELSM (ื ื™ื˜ื•ืจ ืžืฆื‘ ืงื™ืฉื•ืจ ืงื™ืฆื•ื ื™)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ACLs, ืžื™ื•ืฉืžื™ื ืขืœ ื™ืฆื™ืื•ืช ื ื›ื ืกื•ืช

  • IPv4
  • ืกื˜ื˜ื™

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ACLs, ืžื™ื•ืฉืžื™ื ืขืœ ื™ืฆื™ืื•ืช ื ื›ื ืกื•ืช

  • IPv6
  • ื“ื™ื ืžื™

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ACLs, ืžื™ื•ืฉืžื™ื ืขืœ ื™ืฆื™ืื•ืช ื™ืฆื™ืื”
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ACLs, ืžื“ื™ ื›ื ื™ืกื”
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ACLs, ืžื“ื™ ื™ืฆื™ืื”
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ACL

  • ืžื ื”ื•ืจ ืคืจื•ื˜ื•ืงื•ืœ ืฉื›ื‘ื”-2
  • ืžื•ื ื™ื ื‘ืชื™ื

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื–ื™ื”ื•ื™ ื ืงื•ื“ืช ืงืฆื” ื”ืชื›ื ืกื•ืช (CEP).
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

CPU DoS ื”ื’ื ื”
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ื™ื˜ื•ืจ ืžืขื‘ื“
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

Direct Attach - ืžื‘ื•ืกืก ืขืœ ื’ืจืกืช IEEE ืฉืœ VEPA, ืžื‘ื˜ืœ ืืช ืฉื›ื‘ืช ื”ืžืชื’ื™ื ื”ื•ื•ื™ืจื˜ื•ืืœื™ื™ื, ืžืคืฉื˜ ืืช ื”ืจืฉืช ื•ืžืฉืคืจ ืืช ื”ื‘ื™ืฆื•ืขื™ื. Direct Attach ืžืืคืฉืจ ืคื™ืฉื•ื˜ ืžืจื›ื– ื”ื ืชื•ื ื™ื ืขืœ ื™ื“ื™ ื”ืงื˜ื ืช ืฉื›ื‘ื•ืช ื”ืจืฉืช ืžืืจื‘ืข ืื• ื—ืžืฉ ืฉื›ื‘ื•ืช ืœืฉืชื™ื™ื ืื• ืฉืœื•ืฉ ื‘ืœื‘ื“, ื‘ื”ืชืื ืœื’ื•ื“ืœ ืžืจื›ื– ื”ื ืชื•ื ื™ื.
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช

SNMPv3
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืฉืจืช SSH2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืœืงื•ื— SSH2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืœืงื•ื— SCP/SFTP
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืฉืจืช SCP/SFTP
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

RADIUS ื•-TACACS+ ืœื›ืœ ืื™ืžื•ืช ืคืงื•ื“ื”
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื›ื ื™ืกื” ืœืจืฉืช

  • ืฉื™ื˜ื” ืžื‘ื•ืกืกืช ืื™ื ื˜ืจื ื˜
  • ืฉื™ื˜ืช 802.1X
  • ืฉื™ื˜ื” ืžื‘ื•ืกืกืช MAC
  • ืžืกื“ ื ืชื•ื ื™ื ืžืงื•ืžื™ ืœืฉื™ื˜ื•ืช ืžื‘ื•ืกืกื•ืช MAC/ืื™ื ื˜ืจื ื˜
  • ืื™ื ื˜ื’ืจืฆื™ื” ืขื Microsoft NAP
  • ืžืกืคืจ ืžืชื—ืจื™ื - ืื•ืชื• VLAN
  • HTTPS/SSL ืœืฉื™ื˜ื” ืžื‘ื•ืกืกืช ืื™ื ื˜ืจื ื˜

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื”ืชื—ื‘ืจื•ืช ืœืจืฉืช - ืžืกืคืจ ืกืคืงื™ื - ืžืกืคืจ ืจืฉืชื•ืช VLAN
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

OUI ืžื”ื™ืžืŸ
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืื‘ื˜ื—ืช MAC

  • ื ืขื™ืœื”
  • ืœึฐื”ึทื’ื‘ึผึดื™ืœ

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืื‘ื˜ื—ืช IPโ€”ืืคืฉืจื•ืช DHCP 82โ€”ืžืฆื‘ L2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืื‘ื˜ื—ืช IPโ€”ืืคืฉืจื•ืช DHCP 82โ€”ื–ื™ื”ื•ื™ VLAN ื‘ืžืฆื‘ L2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืื‘ื˜ื—ืช IP - ื ืขื™ืœืช DHCP IP
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืื‘ื˜ื—ืช IP - ื™ืฆื™ืื•ืช ืฉืจืช DHCP ืžื”ื™ืžื ื•ืช
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื—ื‘ืจื•ืช ืกื˜ื˜ื™ืช ื‘-IGMP, ืžืกื ื ื™ IGMP
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืžื™ืชื•ื’ IPv4 unicast L2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืžื™ืชื•ื’ IPv4 Multicast L2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืฉื™ื“ื•ืจ ืžื›ื•ื•ืŸ IPv4
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

IPv4

  • ืฉื™ื“ื•ืจ ื™ืฉื™ืจ ืžื”ื™ืจ
  • ื”ืชืขืœื ืžืฉื™ื“ื•ืจ

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืžื™ืชื•ื’ IPv6 unicast L2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืžื™ืชื•ื’ IPv6 Multicast L2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

IPv6 netTools - ืคื™ื ื’, traceroute, ืžืžืกืจ BOOTP, DHCP, DNS ื•-SNTP.
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

IPv4 netTools - ืคื™ื ื’, traceroute, ืžืžืกืจ BOOTP, DHCP, DNS, NTP ื•-SNTP.
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื—ื˜ื˜ื ื•ืช IGMP v1/v2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื—ื˜ื˜ื ื•ืช IGMP v3
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืจื™ืฉื•ื VLAN Multicast (MVR)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื—ื‘ืจื•ืช MLD ืกื˜ื˜ื™ืช, ืžืกื ื ื™ MLD
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื—ื˜ื˜ื ื•ืช MLD v1
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื—ื˜ื˜ื ื•ืช MLD v2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื—ืฉื‘ื•ื ืื•ืช sFlow
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืกืงืจื™ืคื˜ื™ื ืฉืœ CLI
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ื™ื”ื•ืœ ืžื›ืฉื™ืจื™ื ืžื‘ื•ืกืก ืื™ื ื˜ืจื ื˜
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ื™ื”ื•ืœ ืžื‘ื•ืกืก ืื™ื ื˜ืจื ื˜ - ืชืžื™ื›ื” ื‘-HTTPS/SSL
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืžืžืฉืงื™ XML API (ืœืฉื™ืœื•ื‘ ืฉื•ืชืคื™ื)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

MIBs - ื™ืฉื•ืช, ืœืžืœืื™
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ื™ื”ื•ืœ ืชืงืœื•ืช ืงื™ืฉื•ืจื™ื•ืช (CFM)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืฉื™ืงื•ืฃ ืžืจื—ื•ืง
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืฉื™ืงื•ืฃ ื™ืฆื™ืื”
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืžื“ื™ื“ืช ื”ืฉื”ื™ื™ืช ืžืกื’ืจืช ืชื•ืืžืช Y.1731 ื•ืฉื•ื ื•ืช ื”ืฉื”ื™ื”
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

MVRP - ื ื™ื”ื•ืœ ื˜ื•ืคื•ืœื•ื’ื™ื” ืฉืœ VLAN
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

EFM OAM - ื ื™ื”ื•ืœ ืชืงืœื•ืช ืงื™ืฉื•ืจ ื—ื“ ื›ื™ื•ื•ื ื™
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

CLEARFlow
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ืชื‘ื™ื ื•ื™ืจื˜ื•ืืœื™ื™ื ืฉืœ ืžืขืจื›ืช (VRs)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

DHCPv4:

  • ืฉืจืช DHCPv4
  • ืœืงื•ื— DHCv4
  • ืžืžืกืจ DHCPv4
  • ืžืžืกืจ ื—ื›ื DHCPv4
  • ืžื–ื”ื” ืžืจื—ื•ืง DHCPv6

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

DHCPv6:

  • ืžืžืกืจ DHCPv6
  • ื—ื™ื˜ื•ื˜ ื”ืืฆืœืช ืงื™ื“ื•ืžืช DHCPv6
  • ืœืงื•ื— DHCPv6
  • ืžืžืกืจ ื—ื›ื DHCPv6

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ืชื‘ื™ื ื•ื™ืจื˜ื•ืืœื™ื™ื (VR) ืฉื ื•ืฆืจื• ืขืœ ื™ื“ื™ ืžืฉืชืžืฉื™ื
ื ืชื‘ ื•ื”ืขื‘ืจื” ื•ื™ืจื˜ื•ืืœื™ืช (VRF)

Summit X450-G2, X460-G2, X670-G2, X770 ื•-ExtremeSwitching X870, X690

ืฆื‘ื™ืจืช VLAN
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

Multinetting ืœื”ืขื‘ืจื”
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื”ืขื‘ืจืช UDP

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื”ืขื‘ืจืช ืžืžืกืจ UDP BootP
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ื™ืชื•ื‘ unicast IPv4, ื›ื•ืœืœ ืžืกืœื•ืœื™ื ืกื˜ื˜ื™ื™ื
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ื™ืชื•ื‘ ืจื™ื‘ื•ื™ ืฉื™ื“ื•ืจ IPv4, ื›ื•ืœืœ ืžืกืœื•ืœื™ื ืกื˜ื˜ื™ื™ื
ื”ืขืจื”: ืœืชื›ื•ื ื” ื–ื• ื™ืฉ ืžื’ื‘ืœื•ืช ื‘ืจื™ืฉื™ื•ื ื•ืช Edge ื•-Advanced Edge. ืจืื” ืคืจื˜ื™ื ื‘ืžื“ืจื™ืš ืœืžืฉืชืžืฉ ืขื‘ื•ืจ ื’ืจืกืื•ืช EXOS ืฉื•ื ื•ืช.
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื–ื™ื”ื•ื™ ื›ืชื•ื‘ื•ืช ื›ืคื•ืœื•ืช IPv4 (DAD)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ื™ืชื•ื‘ unicast IPv6, ื›ื•ืœืœ ืžืกืœื•ืœื™ื ืกื˜ื˜ื™ื™ื
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืขื‘ื•ื“ื” ื”ื“ื“ื™ืช ืฉืœ IPv6 - ืžื ื”ืจื•ืช ื”ืžื•ื’ื“ืจื•ืช IPv6-to-IPv4 ื•-IPv6-in-IPv4
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช, ืœืžืขื˜ X620 ื•-X440-G2.

ื–ื™ื”ื•ื™ ื›ืชื•ื‘ื•ืช ื›ืคื•ืœื•ืช IPv6 (DAD) ืœืœื ื ื™ื”ื•ืœ CLI
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื–ื™ื”ื•ื™ ื›ืชื•ื‘ื•ืช ื›ืคื•ืœื•ืช IPv6 (DAD) ืขื ื ื™ื”ื•ืœ CLI
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืื‘ื˜ื—ืช IP:

  • DHCP ืืคืฉืจื•ืช 82 - ืžืฆื‘ L3
  • DHCP Option 82 - ืžื–ื”ื” VLAN ื‘ืžืฆื‘ L3
  • ื”ืฉื‘ืช ืืช ืœืžื™ื“ืช ARP
  • ื”ื’ื ืช ARP ืœืœื ืชืฉืœื•ื
  • ืื™ืžื•ืช ARP / ARP ืžืื•ื‘ื˜ื— DHCP
  • ื ืขื™ืœืช ืžืงื•ืจ IP

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืื‘ื˜ื—ืช ื›ืชื•ื‘ืช IP:

  • ื—ื˜ื˜ื ื•ืช ืฉืœ DHCP
  • ืฉืจืช DHCP ืžื”ื™ืžืŸ
  • ื ืขื™ืœืช ืžืงื•ืจ IP
  • ืื™ืžื•ืช ARP

ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื™ื™ืฆื•ื ืžื™ื“ืข ืชื–ืจื™ื IP (IPFIX)
Summit X460-G2.

Multi-Switch Link Aggregation Group (MLAG)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ONEPolicy
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ื™ืชื•ื‘ ืžื‘ื•ืกืก ืžื“ื™ื ื™ื•ืช (PBR) ืขื‘ื•ืจ IPv4
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ื™ืชื•ื‘ ืžื‘ื•ืกืก ืžื“ื™ื ื™ื•ืช (PBR) ืขื‘ื•ืจ IPv6
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื—ื˜ื˜ื ื•ืช PIM
ื”ืขืจื”: ืœืชื›ื•ื ื” ื–ื• ื™ืฉ ืžื’ื‘ืœื•ืช ื‘ืจื™ืฉื™ื•ื ื•ืช Edge ื•-Advanced Edge. ืจืื” ืคืจื˜ื™ื ื‘ืžื“ืจื™ืš ืœืžืฉืชืžืฉ ืขื‘ื•ืจ ื’ืจืกืื•ืช EXOS ืฉื•ื ื•ืช.
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืจืฉืชื•ืช VLAN ืžื‘ื•ืกืกื•ืช ืคืจื•ื˜ื•ืงื•ืœ
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

RIP v1/v2
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

RIPng
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืžื“ื™ื ื™ื•ืช ื’ื™ืฉื” ืœื ื™ืชื•ื‘
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืžืคื•ืช ืžืกืœื•ืœ
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื™ืฆื™ืื” ืื•ื ื™ื‘ืจืกืœื™ืช - ืชืฆื•ืจื” ืื•ื˜ื•ืžื˜ื™ืช ืฉืœ VoIP
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื™ืฆื™ืื” ืื•ื ื™ื‘ืจืกืœื™ืช - ืžื“ื™ื ื™ื•ืช ืื‘ื˜ื—ื” ื“ื™ื ืžื™ืช ืžื‘ื•ืกืกืช ืžืฉืชืžืฉ
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ื ืžืœ ืื•ื ื™ื‘ืจืกืœื™ - ืžื“ื™ื ื™ื•ืช ื”ืฉืขื” ื‘ื™ื•ื
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

SummitStack (ื”ื—ืœืคืช ืขืจื™ืžื” ื‘ืืžืฆืขื•ืช ื™ืฆื™ืื•ืช ืžืงื•ืจื™ื•ืช ืื• ื™ื™ืขื•ื“ื™ื•ืช)
Summit X460-G2 ืขื ื›ืจื˜ื™ืก X460-G2-VIM-2SS ืื•ืคืฆื™ื•ื ืœื™, ื•-X450-G2.

SummitStack-V (ืขืจื™ืžื” ืžืชื’ ื‘ืืžืฆืขื•ืช ื™ืฆื™ืื•ืช ื ืชื•ื ื™ื ื“ื•-ืžื˜ืจื™ื•ืช)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช. ืขื™ื™ืŸ ื‘ื“ื’ืžื™ื ื”ืกืคืฆื™ืคื™ื™ื ื”ืžืคื•ืจื˜ื™ื ื‘ืกืขื™ืฃ "ืชืžื™ื›ื” ืขื‘ื•ืจ ื™ืฆื™ืื•ืช ืขืจื™ืžื” ื—ืœื•ืคื™ื•ืช" ื‘ืžื“ืจื™ืš ืœืžืฉืชืžืฉ.

SyncE
Summit X460-G2.

ืชืกืจื™ื˜ ืคื™ื™ืชื•ืŸ
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ืจื™ืฉื™ื•ืŸ ืื“ื’' ืžืชืงื“ื

ืชื›ื•ื ืช ืชื•ื›ื ืช ExtremeXOS
ืคืœื˜ืคื•ืจืžื•ืช ื ืชืžื›ื•ืช

EAPS Advanced Edge - ื˜ื‘ืขื•ืช ืคื™ื–ื™ื•ืช ืžืจื•ื‘ื•ืช ื•"ืงื™ืฉื•ืจื™ื ืžืฉื•ืชืคื™ื", ื”ืžื›ื•ื ื” ื’ื "ื™ืฆื™ืื” ืžืฉื•ืชืคืช".
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ERPS-more ืชื—ื•ืžื™ื (ืžืืคืฉืจ 32 ื˜ื‘ืขื•ืช ืขื ื™ืฆื™ืื•ืช ื˜ื‘ืขื•ืช ืชื•ืืžื•ืช) ื•ืชืžื™ื›ื” ื‘ืจื™ื‘ื•ื™ ื˜ื‘ืขื•ืช
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ESRP-ืžืœื
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

ESRP-MAC ื•ื™ืจื˜ื•ืืœื™
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช.

OSPFv2-Edge (ืžื•ื’ื‘ืœ ืœ-4 ืžืžืฉืงื™ื ืคืขื™ืœื™ื ืœื›ืœ ื”ื™ื•ืชืจ)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช ื”ืชื•ืžื›ื•ืช ื‘ืจื™ืฉื™ื•ื ื•ืช Advanced Edge ืื• Core

OSPFv3-Edge (ืžื•ื’ื‘ืœ ืœ-4 ืžืžืฉืงื™ื ืคืขื™ืœื™ื ืœื›ืœ ื”ื™ื•ืชืจ)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช ื”ืชื•ืžื›ื•ืช ื‘ืจื™ืฉื™ื•ื ื•ืช Advanced Edge ืื• Core

PIM-SM-Edge (ืžื•ื’ื‘ืœ ืœ-4 ืžืžืฉืงื™ื ืคืขื™ืœื™ื ืœื›ืœ ื”ื™ื•ืชืจ)
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช ื”ืชื•ืžื›ื•ืช ื‘ืจื™ืฉื™ื•ื ื•ืช Advanced Edge ืื• Core

VRRP
ื›ืœ ื”ืคืœื˜ืคื•ืจืžื•ืช ื”ืชื•ืžื›ื•ืช ื‘ืจื™ืฉื™ื•ื ื•ืช Advanced Edge ืื• Core

VXLAN
Summit X770, X670-G2, ื•-ExtremeSwitching X870, X690.

OVSDB
Summit X770, X670-G2, ื•-ExtremeSwitching X870, X690.

PSTag
ืžืชื’ื™ื ืžืกื“ืจืช Summit X460-G2, X670-G2, X770 ื•-ExtremeSwitching X870, X690.

ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

ืชื›ื•ื ืช ืชื•ื›ื ืช ExtremeXOS
ืคืœื˜ืคื•ืจืžื•ืช ื ืชืžื›ื•ืช

PIM DM "ืžืœื"
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

PIM SM "ืžืœื"
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

PIM SSM "ืžืœื"
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

OSPFv2 "ืžืœื" (ืœื ืžื•ื’ื‘ืœ ืœ-4 ืžืžืฉืงื™ื ืคืขื™ืœื™ื)
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

OSPFv3 "ืžืœื" (ืœื ืžื•ื’ื‘ืœ ืœ-4 ืžืžืฉืงื™ื ืคืขื™ืœื™ื)
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

BGP4 ื•-MBGP (BGP4+) ืขื‘ื•ืจ IPv4 ECMP
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

BGP4 ื•-MBGP (BGP4+) ืขื‘ื•ืจ IPv6
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

IS-IS ืขื‘ื•ืจ IPv4
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

IS-IS ืขื‘ื•ืจ IPv6
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

MSDP
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

Anycast RP
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

ืžื ื”ื•ืจ GRE
ืคืœื˜ืคื•ืจืžื•ืช ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื”

ื›ื“ื™ ืœื”ืคืขื™ืœ ืืช ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืฉืœ MPLS, ื™ืฉื ืŸ ื—ื‘ื™ืœื•ืช ืชื›ื•ื ื•ืช ื ืคืจื“ื•ืช, ืขืœื™ื”ืŸ ืื“ื•ืŸ ื‘ื”ืžืฉืš.

ืกื“ืจืช X440-G2

ืื ื™ ืžืฆื™ืข ืœื”ืชื—ื™ืœ ืืช ื”ืกืงื™ืจื” ืฉืœื ื• ืขืœ ืžืชื’ื™ EXOS ืขื ื”ืžืชื’ื™ื ืฉืœ ืกื“ืจื” ื–ื•, ืฉืžืชืืจื™ื ื‘ื‘ื™ืจื•ืจ ืืช ื”ืžื•ืฉื’ "ืฉืœื-ื›ืฉืชื’ื“ืœ", ื”ื ืชืžืš ื‘ืื•ืคืŸ ืคืขื™ืœ ืขืœ-ื™ื“ื™ ExtremeNetworks.

ื”ืจืขื™ื•ืŸ ื”ืžืจื›ื–ื™ ืฉืœ ืจืขื™ื•ืŸ ื–ื” ื”ื•ื ืœื”ื’ื“ื™ืœ ื‘ื”ื“ืจื’ื” ืืช ื”ืคืจื•ื“ื•ืงื˜ื™ื‘ื™ื•ืช ื•ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืฉืœ ืฆื™ื•ื“ ืฉื ืจื›ืฉ ื•ืžื•ืชืงืŸ ืœืœื ืฆื•ืจืš ื‘ื”ื—ืœืคืช ื”ืฆื™ื•ื“ ืขืฆืžื• ืื• ื—ืœืงื™ื•.

ืœืฉื ื”ื‘ื”ื™ืจื•ืช, ืืชืŸ ืืช ื”ื“ื•ื’ืžื” ื”ื‘ืื”:

  • ื ื ื™ื— ืฉื‘ื”ืชื—ืœื” ืืชื” ืฆืจื™ืš ืžืชื’ ืฉืœ 24 ืื• 48 ื™ืฆื™ืื•ืช ืขื ื™ืฆื™ืื•ืช ื’ื™ืฉื” ื ื—ื•ืฉืช ืื• ืื•ืคื˜ื™ื•ืช, ืฉื‘ื”ืชื—ืœื” ื™ื”ื™ื• 50% ืžื™ืฆื™ืื•ืช ื”ื’ื™ืฉื” ืชืคื•ืกื•ืช (12 ืื• 24 ื—ืœืงื™ื) ื•ืืช ื”ืชืขื‘ื•ืจื” ื”ื›ื•ืœืœืช ืฉืœ ื™ืฆื™ืื•ืช ื”ืžื˜ืขืŸ ื‘ืื—ืช ื›ื™ื•ื•ื ื™ื (ื‘ื“ืจืš ื›ืœืœ ืžื“ื•ื‘ืจ ื‘-downlink ืขื‘ื•ืจ ืžื›ื•ื ื•ืช ืขื•ื‘ื“ื•ืช) ื™ื”ื™ื• ืขื“ 1 Gbit/s
  • ื ื ื™ื— ืฉื‘ื—ืจืช ื‘ืชื—ื™ืœื” ืืช ืžืชื’ X440-G2-24t-10GE4 ืื• X440-G2-48t-10GE4, ืฉื™ืฉ ืœื”ื 24 ืื• 48 ื™ืฆื™ืื•ืช ื’ื™ืฉื” ืฉืœ 1000 BASE-T ื•-4 ื™ืฆื™ืื•ืช GigabitEthernet SFP/SFP+ ืขื ื”ื™ื›ื•ืœืช ืœื”ืจื—ื™ื‘ ืื•ืชืŸ ืœ-10 GigabitEthernet
  • ื”ื’ื“ืจืช ื•ื”ืชืงื ืช ืืช ื”ืกื•ื•ื™ืฅ', ื›ืœืœืช ืื•ืชื• ืขื ื™ืฆื™ืืช ื˜ืจืื ืง 1 ื‘ืœื™ื‘ื” ืื• ื‘ืฆื‘ื™ืจื” (ืชืœื•ื™ ื‘ืžื‘ื ื” ื”ืจืฉืช ืฉืœืš), ื—ื™ื‘ืจืช ืืœื™ื• ืžืฉืชืžืฉื™ื - ื”ื›ืœ ืขื•ื‘ื“, ืืชื” ื•ื”ื”ื ื”ืœื” ืžืจื•ืฆื™ื
  • ืขื ื”ื–ืžืŸ, ื”ืงืžืคื™ื™ืŸ ื•ื”ืจืฉืช ืฉืœืš ื’ื“ืœื™ื - ืžืฉืชืžืฉื™ื ื—ื“ืฉื™ื, ืฉื™ืจื•ืชื™ื, ืฆื™ื•ื“ ืžื•ืคื™ืขื™ื
  • ื›ืชื•ืฆืื” ืžื›ืš, ื’ื™ื“ื•ืœ ืชืขื‘ื•ืจื” ืืคืฉืจื™ ื‘ืจืžื•ืช ืฉื•ื ื•ืช ืฉืœ ื”ืจืฉืช, ื›ื•ืœืœ ืขืœ ื”ืžืชื’ ืฉืื ื• ืฉื•ืงืœื™ื. ื–ื” ื™ื›ื•ืœ ืœืงืจื•ืช ืžืกื™ื‘ื•ืช ืฉื•ื ื•ืช - ืืชื” ืžื—ื‘ืจ ืžื›ืฉื™ืจื™ื ื—ื“ืฉื™ื ืœืžืชื’, ืื• ืฉืžืฉืชืžืฉื™ื ืžืชื—ื™ืœื™ื ืœืฆืจื•ืš ื™ื•ืชืจ ื•ื™ื•ืชืจ ืชืขื‘ื•ืจื” ืžืฉื™ืจื•ืชื™ื ืฉื•ื ื™ื, ื•ื‘ื“ืจืš ื›ืœืœ ืฉื ื™ื”ื ืงื•ืจื™ื ื‘ื•-ื–ืžื ื™ืช
  • ืขื ื”ื–ืžืŸ, ืืชื” ืฉื ืœื‘ ืฉื”ืขื•ืžืก ืขืœ ื™ืฆื™ืืช ื”ืžื˜ืขืŸ ืฉืœ ื”ืžืชื’ ื”ื’ื™ืข ืœ-1 Gbps
  • ืœื ื‘ืขื™ื”, ืืชื” ื—ื•ืฉื‘, ืžื›ื™ื•ื•ืŸ ืฉื™ืฉ ืœืš ืขื•ื“ 3 ื™ืฆื™ืื•ืช GigabitEthernet ืฉื‘ื”ืŸ ืืชื” ื™ื›ื•ืœ ืœื”ืฉืชืžืฉ ื›ื“ื™ ืœืฆื‘ื•ืจ ืงื™ืฉื•ืจื™ ืชืงืฉื•ืจืช ื‘ื™ืŸ ื”ืžืชื’ ืœืฆื‘ื™ืจื” (ื”ืœื™ื‘ื”) - ืืชื” ืžืขืœื” ืขื•ื“ ืงื™ืฉื•ืจ ืื•ืคื˜ื™ ืื• ื ื—ื•ืฉืช ื‘ื™ื ื™ื”ืŸ ื•ืžื’ื“ื™ืจ ืืช ื”ืฆื‘ื™ืจื”, ืœืžืฉืœ, ื‘ืืžืฆืขื•ืช ื”ืคืจื•ื˜ื•ืงื•ืœ LACP
  • ื”ื–ืžืŸ ืขื•ื‘ืจ ื•ืขื•ืœื” ื”ืฆื•ืจืš ืœื”ืชืงื™ืŸ ืžืชื’ ืื—ื“ ืื• ื™ื•ืชืจ
  • ืขืฉื•ื™ื™ื ืœื”ื™ื•ื•ืฆืจ ืžืกืคืจ ืžืฆื‘ื™ื ืฉื™ื’ืจืžื• ืœื›ืš ืฉืชืฆื˜ืจืš ืœื”ืคืขื™ืœ ืžืชื’ ื—ื“ืฉ ื“ืจืš ืžืชื’ X440 ื”ืงื™ื™ื ืฉืœืš:
    • ื”ื™ืขื“ืจ ื™ืฆื™ืื•ืช ืฆื‘ื™ืจื” ืื• ืœื™ื‘ื” ื›ื“ื™ ืœืืคืฉืจ - ื‘ืžืงืจื” ื–ื”, ืชืฆื˜ืจืš ืœืจื›ื•ืฉ ืžืชื’ื™ ืฆื‘ื™ืจื” ื ื•ืกืคื™ื ืื• ืจืžืช ื”ืœื™ื‘ื”
    • ื”ืจื™ื—ื•ืง ืฉืœ ื”ืžืชื’ ืžืฆืžืชื™ ื”ืฆื‘ื™ืจื” ืื• ื—ื•ืกืจ ื”ืงื™ื‘ื•ืœืช ื”ืงื™ื™ืžืช ืฉืœ ืชื•ื•ืื™ ื”ื›ื‘ืœื™ื, ืœืžืฉืœ, ืกื™ื‘ื™ื ืื•ืคื˜ื™ื™ื, ื™ื—ื™ื™ื‘ื• ื‘ื ื™ื™ืช ืงื•ื•ื™ ืชืงืฉื•ืจืช ื—ื“ืฉื™ื ื•ืขืœื•ื™ื•ืช ื ื•ืกืคื•ืช ืžืฉืžืขื•ืชื™ื•ืช.
    • ื‘ืžืงืจื” ื”ื’ืจื•ืข ื‘ื™ื•ืชืจ, ืฉืชื™ ืืคืฉืจื•ื™ื•ืช ืืคืฉืจื™ื•ืช ื‘ื•-ื–ืžื ื™ืช

  • ืœืื—ืจ ืกืงื™ืจืช ืขื™ืฆื•ื‘ ื”ืจืฉืช ื•ืขืœื•ื™ื•ืช ื ื•ืกืคื•ืช ืขื ื”ื”ื ื”ืœื”, ืืชื” ืžื—ืœื™ื˜ ืœื—ื‘ืจ ืžืชื’ X440 ื—ื“ืฉ ืœืจืฉืช ื“ืจืš ื”ืงื™ื™ื. ืื™ืŸ ื‘ืขื™ื” - ื™ืฉ ืœืš ืžืกืคืจ ืืคืฉืจื•ื™ื•ืช ืœื›ืš:
    • ืืคืฉืจื•ืช 1 - ืขืจื™ืžื”:
      • ืืชื” ื™ื›ื•ืœ ืœืขืจื•ื 2 ืžืชื’ื™ื ื‘ืืžืฆืขื•ืช ื˜ื›ื ื•ืœื•ื’ื™ื™ืช SummitStack-V ื‘ืืžืฆืขื•ืช 2 ื™ืฆื™ืื•ืช ื”ืžื˜ืขืŸ ื”ื ื•ืชืจื•ืช ื‘ืžืชื’ X440 ื”ืจืืฉื•ืŸ ื•-2 ื™ืฆื™ืื•ืช ื”ืžื˜ืขืŸ ื‘ืžืชื’ X440 ื”ืฉื ื™
      • ื‘ื”ืชืื ืœืžืจื—ืง, ื ื™ืชืŸ ืœื”ืฉืชืžืฉ ื’ื ื‘ื›ื‘ืœื™ DAC ื‘ืื•ืจืš ืงืฆืจ ื•ื’ื ื‘ืžืงืœื˜ื™ ืžืฉื“ืจ SFP+ ืขื“ ื›ืžื” ืขืฉืจื•ืช ืงื™ืœื•ืžื˜ืจื™ื
      • ืœืคื™ื›ืš, ื”ืขืจืžื” ืฉืœ ืžืชื’ื™ื ืชืชื‘ืฆืข ื“ืจืš 2 ื™ืฆื™ืื•ืช ืฉื”ื•ืงืฆื• ืœ-Stacking ืžืชื•ืš 4 ื™ืฆื™ืื•ืช ื˜ืจืื ืง (ื‘ื“ืจืš ื›ืœืœ ื™ืฆื™ืื•ืช 27, 28 ื‘ื“ื’ืžื™ 24 ื™ืฆื™ืื•ืช ื•ื™ืฆื™ืื•ืช 49, 50 ื‘ื“ื’ืžื™ 48 ื™ืฆื™ืื•ืช). ืจื•ื—ื‘ ื”ืคืก ืฉืœ ื™ืฆื™ืื•ืช ื”ืขืจื™ืžื” ื‘ื›ืœ ื™ืฆื™ืื” ื™ื”ื™ื” 20Gb (10Gb ื‘ื›ื™ื•ื•ืŸ ืื—ื“ ื•-10Gb ื‘ื›ื™ื•ื•ืŸ ื”ืฉื ื™)
      • ื‘ืžืงืจื” ื–ื”, ืื™ืŸ ืฆื•ืจืš ื‘ืจื™ืฉื™ื•ืŸ ืœื”ืจื—ื‘ืช ื™ืฆื™ืื•ืช ื”ืžื˜ืขืŸ ืž-1 GE ืœ-10 GE

    • ืืคืฉืจื•ืช 2 - ืฉื™ืžื•ืฉ ื‘ื™ืฆื™ืื•ืช ืžื˜ืขืŸ ืขื ืืคืฉืจื•ืช ืœืฆื‘ื™ืจื” ื ื•ืกืคืช ืฉืœื”ืŸ:
      • ืืชื” ื™ื›ื•ืœ ืœื”ืคืขื™ืœ ืžืชื’ ืฉื ื™ ื‘ืืžืฆืขื•ืช 1 ืื• 2 (ื‘ืžืงืจื” ืฉืœ ืฆื‘ื™ืจื”) ื™ืฆื™ืื•ืช ื˜ืจืื ืง ืฉื ื•ืชืจื• ื‘-X440 ื”ืจืืฉื•ืŸ ื•-1 ืื• 2 ื™ืฆื™ืื•ืช ื˜ืจืื ืง ื‘-X440 ื”ื—ื“ืฉ
      • ื’ื ื›ืืŸ ืื™ืŸ ืฆื•ืจืš ื‘ืจื™ืฉื™ื•ืŸ ืœื”ืจื—ื‘ืช ื™ืฆื™ืื•ืช ืžื˜ืขืŸ ืž-1 GE ืœ-10 GE.
  • ื—ื™ื‘ืจืชื ืžืชื’ ืื—ื“ ืื• ื™ื•ืชืจ ื‘ืกื“ืจื”, ืื• ื›ื•ื›ื‘ื™ืช, ืžื”ืžืชื’ X440 ื”ืจืืฉื•ืŸ ื›ืคื™ ืฉืชื›ื ื ืชื
  • ื”ื–ืžืŸ ืขื•ื‘ืจ ื•ืืชื” ืฉื ืœื‘ ืฉื”ืชืขื‘ื•ืจื” ื‘ื™ืฆื™ืื•ืช ื”ืžื˜ืขืŸ ืฉืœ ืžืชื’ X440 ื”ืจืืฉื•ืŸ ื”ื’ื™ืขื” ืœ-2 Gbps ื•ืืชื” ืฆืจื™ืš:
    • ืื• ื™ื•ืชืจ ื™ืฆื™ืื•ืช ืœืฆื‘ื™ืจื” ืงื™ืฉื•ืจื™ื ื‘ื™ืŸ ื”ืฆื‘ื™ืจื” ืœืžืชื’ X440 ื”ืจืืฉื•ืŸ, ืžื” ืฉื‘ืชื•ืจื• ื™ื›ื•ืœ ืœื”ื•ื‘ื™ืœ ืื•ืชืš ืœืื•ืชืŸ ื‘ืขื™ื•ืช ื›ืžื• ื‘ืขืช ื”ืชืงื ืช ืžืชื’ X440 ื—ื“ืฉ, ืฉืชื™ืืจืชื™ ืœืžืขืœื” - ื—ื•ืกืจ ื™ืฆื™ืื•ืช ื‘ืฆื™ื•ื“ ื”ืฆื‘ื™ืจื” ืื• ืงื™ื‘ื•ืœืช ืชืฉืชื™ืช ื”ื›ื‘ืœื™ื
    • ืื• ื”ืฉืชืžืฉื• ื‘- trunk 10 ื™ืฆื™ืื•ืช GigabitEthernet ื‘ื™ืŸ ืฆื™ื•ื“ ื”ืฆื‘ื™ืจื” ืœืžืชื’ X440 ื”ืจืืฉื•ืŸ

  • ื‘ืฉืœื‘ ื–ื”, ื”ื™ื›ื•ืœืช ืฉืœ ืžืชื’ื™ X440 ืœื”ืจื—ื™ื‘ ืืช ืจื•ื—ื‘ ื”ืคืก ืฉืœ ื™ืฆื™ืื•ืช ื”ื˜ืจืื ืง ืฉืœื”ื ืž-1 GigabitEthernet ืœ-10 GigabitEthernet, ื‘ืืžืฆืขื•ืช ื”ืจื™ืฉื™ื•ืŸ ื”ืžืชืื™ื, ืชื‘ื•ื ืœืขื–ืจืชื›ื. ื‘ื”ืชืื ืœืืคืฉืจื•ื™ื•ืช ืฉืชื—ืœื™ื˜:
    • ืขื‘ื•ืจ ืืคืฉืจื•ืช 1 (ืขืจื™ืžื”) - ื”ืฉืชืžืฉ ื‘ืจื™ืฉื™ื•ืŸ ืฉื“ืจื•ื’ ื›ืคื•ืœ 10GbE. ืืชื” ืžืคืขื™ืœ ืจื™ืฉื™ื•ืŸ ื‘-X440 ื”ืจืืฉื•ืŸ, ืฉื™ืจื—ื™ื‘ ืืช ื”ืชืคื•ืงื” ืฉืœ 2 ื™ืฆื™ืื•ืช ื”ื˜ืจืื ืง ืฉืœื• ืž-1 GigabitEthernet ืœ-10 GigabitEthernet (ืฉืชื™ ื”ื™ืฆื™ืื•ืช ื”ื ื•ืชืจื•ืช, ื›ื–ื›ื•ืจ, ืžืฉืžืฉื•ืช ืœืขืจื•ื)
    • ืขื‘ื•ืจ ืืคืฉืจื•ืช 2 (ื™ืฆื™ืื•ืช ืชื ื”ืžื˜ืขืŸ) - ื”ืฉืชืžืฉ ื‘ืจื™ืฉื™ื•ืŸ ืฉื“ืจื•ื’ ื›ืคื•ืœ 10GbE ืื• ืจื™ืฉื™ื•ืŸ ืฉื“ืจื•ื’ Quad 10GbE, ื‘ื”ืชืื ืœืขื•ืžืก ืขืœ ื™ืฆื™ืื•ืช ื”ืžื˜ืขืŸ ื‘ื™ืŸ ื”-X440 ื”ืจืืฉื•ืŸ ืœ-X440 ื”ืฉื ื™. ืขืฉื•ื™ื•ืช ืœื”ื™ื•ืช ื›ืืŸ ื’ื ืžืกืคืจ ืืคืฉืจื•ื™ื•ืช:
      • ืชื—ื™ืœื” ืชื•ื›ืœ ืœื”ืคืขื™ืœ ืจื™ืฉื™ื•ืŸ Dual 10GbE ื‘-X440 ื”ืจืืฉื•ืŸ
      • ืœืื—ืจ ืžื›ืŸ, ื›ื›ืœ ืฉื”ืชืขื‘ื•ืจื” ื‘-X440 ื”ืฉื ื™ ื’ื“ืœื” ืขืงื‘ ื—ื™ื‘ื•ืจ ืฉืœ ืžืชื’ ืื—ื“ ืื• ื™ื•ืชืจ ื‘ืกื“ืจื” ืืœื™ื•, ืืชื” ืžืคืขื™ืœ ืจื™ืฉื™ื•ืŸ Dual 10GbE ื ื•ืกืฃ ื‘-X440 ื”ืจืืฉื•ืŸ ื•ืจื™ืฉื™ื•ืŸ Dual 10GbE ื‘ืžืชื’ X440 ื”ืฉื ื™
      • ื•ื›ืŸ ื”ืœืื” ื‘ืจืฆืฃ ืœืื•ืจืš ืขื ืฃ ื”ืžืชื’ื™ื
  • ืขื•ื‘ืจ ืขื•ื“ ืงืฆืช ื–ืžืŸ, ื”ืืจื’ื•ืŸ ืฉืœืš ืžืžืฉื™ืš ืœืฆืžื•ื— ื”ืŸ ื‘ืฆื•ืจื” ืื•ืคืงื™ืช โ€“ ืžืกืคืจ ืฆืžืชื™ ื”ืจืฉืช ื’ื“ืœ, ื•ื”ืŸ ืื ื›ื™ืช โ€“ ืžื‘ื ื” ื”ืจืฉืช ื”ื•ืคืš ืžื•ืจื›ื‘ ื™ื•ืชืจ, ืฆืฆื™ื ืฉื™ืจื•ืชื™ื ื—ื“ืฉื™ื ืฉื“ื•ืจืฉื™ื ื”ืคืขืœื” ืฉืœ ืคืจื•ื˜ื•ืงื•ืœื™ื ืกืคืฆื™ืคื™ื™ื.
  • ื‘ื”ืชืื ืœืฆืจื›ื™ ื”ืืจื’ื•ืŸ ืฉืœืš, ื™ื™ืชื›ืŸ ืฉืชื—ืœื™ื˜ ืœื”ืชืจื—ืง ืž-L2 ื‘ืžืชื’ื™ื ืฉืœืš ืœ-L3. ื”ืฆืจื›ื™ื ืฉืขืฉื•ื™ื™ื ืœื”ืฉืคื™ืข ืขืœ ื”ื”ื—ืœื˜ื” ืฉืœืš ื™ื›ื•ืœื™ื ืœื”ื™ื•ืช ืฉื•ื ื™ื ืžืื•ื“:
    • ื“ืจื™ืฉื•ืช ืื‘ื˜ื—ืช ื”ืจืฉืช
    • ืื•ืคื˜ื™ืžื™ื–ืฆื™ื” ืฉืœ ืจืฉืช (ืœื“ื•ื’ืžื”, ื”ืคื—ืชืช ืชื—ื•ืžื™ ืฉื™ื“ื•ืจ, ืžืœื•ื•ื” ื‘ื”ื›ื ืกืช ืคืจื•ื˜ื•ืงื•ืœื™ ื ื™ืชื•ื‘ ื“ื™ื ืžื™ื™ื ื›ื’ื•ืŸ OSPF)
    • ื”ื˜ืžืขืช ืฉื™ืจื•ืชื™ื ื—ื“ืฉื™ื ื”ื“ื•ืจืฉื™ื ืคืจื•ื˜ื•ืงื•ืœื™ื ืกืคืฆื™ืคื™ื™ื
    • ื›ืœ ืกื™ื‘ื•ืช ืื—ืจื•ืช

  • ืื™ืŸ ื‘ืขื™ื”. ืžืชื’ื™ X440 ืขื“ื™ื™ืŸ ื™ื”ื™ื• ืจืœื•ื•ื ื˜ื™ื™ื, ืฉื›ืŸ ื ื™ืชืŸ ื‘ื ื•ืกืฃ ืœืจื›ื•ืฉ ื•ืœื”ืคืขื™ืœ ืขื‘ื•ืจื ืจื™ืฉื™ื•ืŸ ื”ืžืจื—ื™ื‘ ืืช ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืฉืœื”ื - Advanced Software License.

ื›ืคื™ ืฉื ื™ืชืŸ ืœืจืื•ืช ืžื”ื“ื•ื’ืžื” ืฉืชื™ืืจืชื™, ืžืชื’ื™ ื”-X440 (ื•ืจื•ื‘ ืกื“ืจื•ืช ื”ืžืชื’ื™ื ื”ืื—ืจื•ืช) ืขื•ืžื“ื™ื ื‘ืขืงืจื•ืŸ "ืฉืœื-ื›ืคื™-ืชื’ื“ืœ". ืืชื” ืžืฉืœื ื›ื“ื™ ืœื”ื•ืกื™ืฃ ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืžืชื’ ื›ื›ืœ ืฉื”ืืจื’ื•ืŸ ื•ื”ืจืฉืช ืฉืœืš ื’ื“ืœื™ื.

ื‘ื ื™ืžื” ื–ื•, ืื ื™ ืžืฆื™ืข ืœื”ืฉืื™ืจ ืืช ื”ืžื™ืœื™ื ื•ืœื”ืชืงืจื‘ ืœืฉื™ืงื•ืœ ืฉืœ ืžืชื’ื™ื.

ื‘ืจืฆื•ื ื™ ืœืฆื™ื™ืŸ ืฉื™ืฉ ื”ืจื‘ื” ืืคืฉืจื•ื™ื•ืช ืชืฆื•ืจื” ืขื‘ื•ืจ ืกื“ืจืช X440, ื›ืคื™ ืฉืืชื” ื™ื›ื•ืœ ืœืจืื•ืช ื‘ืขืฆืžืš ืขืœ ื™ื“ื™ ื”ืชื‘ื•ื ื ื•ืช ื‘ื˜ื‘ืœื” ืœืžื˜ื”:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

* ืžืชื’ื™ื ืžืกื“ืจืช X440-G2 ืชื•ืžื›ื™ื ื‘ืขืจื™ืžื” ืฉืœ SummitStack-V ืขื ืกื“ืจื•ืช ืžืชื’ื™ื ืื—ืจื•ืช - X450-G2, X460-G2, X670-G2 ื•-X770. ื”ืชื ืื™ ื”ืขื™ืงืจื™ ืœื”ืขืจืžื” ืžื•ืฆืœื—ืช ื”ื•ื ื”ืฉื™ืžื•ืฉ ื‘ืื•ืชื” ื’ืจืกื” ืฉืœ EXOS ืขืœ ืžืชื’ื™ ื”ืขืจื™ืžื”.
** ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ื”ื‘ืกื™ืกื™ืช ืฉืœ ื”ื˜ื‘ืœื” ืžืฆื™ื’ื” ืจืง ื—ืœืง ืžื”ื™ื›ื•ืœื•ืช ืฉืœ ืžืชื’ื™ ื”ืกื“ืจื”. ื ื™ืชืŸ ืœืžืฆื•ื ืชื™ืื•ืจ ืžืœื ื™ื•ืชืจ ืฉืœ ืคืจื•ื˜ื•ืงื•ืœื™ื ื•ืชืงื ื™ื ื ืชืžื›ื™ื ื‘ื˜ื‘ืœืช Edge License.

ืžืชื’ื™ื ื‘ืกื“ืจื” ื–ื• ืžืฆื•ื™ื“ื™ื ื‘ื›ื ื™ืกื•ืช ื ื•ืกืคื•ืช - ื›ื ื™ืกืช ืžืชื— ืžื™ื•ืชืจืช ืœื—ื™ื‘ื•ืจ ืกืคืงื™ ื›ื•ื— RPS ืื• ืกื•ืœืœื•ืช ื—ื™ืฆื•ื ื™ื•ืช ื“ืจืš ืžืžื™ืจื™ ืžืชื—.

ื”ืจื™ืฉื™ื•ื ื•ืช ื”ื‘ืื™ื ื–ืžื™ื ื™ื ืขื‘ื•ืจ ืžืชื’ื™ ืกื“ืจืช X440-G2:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืœื”ืœืŸ ืžืกืคืจ ืชืžื•ื ื•ืช ื”ืžืฆื™ื’ื•ืช ืืช ื”ืžืชื’ื™ื ืžืกื“ืจืช X440:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืกื“ืจืช X450-G2

ExtremeNetworks ืžืฆื™ื‘ื” ืืช ืกื“ืจืช Summit X450-G2 ื›ืžืชื’ ืงืฆื” ื™ืขื™ืœ ืœืงืžืคื•ืกื™ื.

ื”ื”ื‘ื“ืœ ื”ืขื™ืงืจื™ ื‘ื™ืŸ ืžืชื’ื™ X450-G2 ืœืกื“ืจืช X440-G2 ื”ื•ื ื›ื“ืœืงืžืŸ:

  • ืกื˜ ืžื•ืจื—ื‘ ืฉืœ ืจื™ืฉื™ื•ื ื•ืช (ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืืคืฉืจื™ืช) - Edge License, Advanced Edge License, Core License
  • ื”ื ื•ื›ื—ื•ืช ืฉืœ ื™ืฆื™ืื•ืช QSFP ื ืคืจื“ื•ืช ืœืขืจื•ื ื”ืžืžื•ืงืžื•ืช ืขืœ ื”ื›ื™ืกื•ื™ ื”ืื—ื•ืจื™ ืฉืœ ื”ืžืชื’ื™ื
  • ื”ื™ื›ื•ืœืช ืœืฆื™ื™ื“ ื“ื’ืžื™ื ื‘ืชืžื™ื›ืช PoE ืขื ืกืคืง ื›ื•ื— ื ื•ืกืฃ
  • ืชืžื™ื›ื” ื‘ืชืงื ื™ื 
  • ืžืชื’ื™ื ืขื ื™ืฆื™ืื•ืช 10GE SFP+ ืื™ื ื ื“ื•ืจืฉื™ื ืจื›ื™ืฉื” ื ื•ืกืคืช ืฉืœ ืจื™ืฉื™ื•ืŸ ื ืคืจื“ ืœื”ืจื—ื‘ืช ืจื•ื—ื‘ ื”ืคืก ืฉืœ ื”ื™ืฆื™ืื” ืž-1 GB ืœ-10 GB

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

*ืขืจื™ืžื” ืฉืœ SummitStack-V84 ื ืชืžื›ืช ื‘ืกื“ืจืช X450-G2 ื‘ืœื‘ื“.
**ืžืชื’ื™ ืกื“ืจืช X440-G2 ืชื•ืžื›ื™ื ื‘ืขืจื™ืžื” ืฉืœ SummitStack-V ืขื ืกื“ืจื•ืช ืžืชื’ื™ื ืื—ืจื•ืช - X440-G2, X460-G2, X670-G2 ื•-X770. ื”ืชื ืื™ ื”ืขื™ืงืจื™ ืœื”ืขืจืžื” ืžื•ืฆืœื—ืช ื”ื•ื ื”ืฉื™ืžื•ืฉ ื‘ืื•ืชื” ื’ืจืกื” ืฉืœ EXOS ืขืœ ืžืชื’ื™ ื”ืขืจื™ืžื”.
*** ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ื”ื‘ืกื™ืกื™ืช ืฉืœ ื”ื˜ื‘ืœื” ืžืฆื™ื’ื” ืจืง ื—ืœืง ืžื”ื™ื›ื•ืœื•ืช ืฉืœ ืžืชื’ื™ ื”ืกื“ืจื”. ื ื™ืชืŸ ืœืžืฆื•ื ืชื™ืื•ืจ ืžืœื ื™ื•ืชืจ ืฉืœ ืคืจื•ื˜ื•ืงื•ืœื™ื ื•ืชืงื ื™ื ื ืชืžื›ื™ื ื‘ื˜ื‘ืœืช Edge License.

ืžืชื’ื™ื ืžืกื“ืจื” ื–ื• ืœืœื PoE ืžืฆื•ื™ื“ื™ื ื‘ื›ื ื™ืกื•ืช ื ื•ืกืคื•ืช - ื›ื ื™ืกืช ืžืชื— ืžื™ื•ืชืจืช ืœื—ื™ื‘ื•ืจ ืกืคืงื™ ื›ื•ื— RPS ืื• ืกื•ืœืœื•ืช ื—ื™ืฆื•ื ื™ื•ืช ื“ืจืš ืžืžื™ืจื™ ืžืชื—.

ืžืชื’ื™ื ื‘ืกื“ืจื” ื–ื• ืžืกื•ืคืงื™ื ืœืœื ืžื•ื“ื•ืœ ืžืื•ื•ืจืจ. ื™ืฉ ืœื”ื–ืžื™ืŸ ืื•ืชื• ื‘ื ืคืจื“.

ื”ืจื™ืฉื™ื•ื ื•ืช ื”ื‘ืื™ื ื–ืžื™ื ื™ื ืขื‘ื•ืจ ืžืชื’ื™ ืกื“ืจืช X450-G2:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื ื™ืชืŸ ืœืจืื•ืช ืชืžื•ื ื” ืฉืœ ืžืชื’ื™ ืกื“ืจืช X450-G2 ืœื”ืœืŸ:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืกื“ืจืช X460-G2

ืžืชื’ื™ื ืžืกื“ืจืช X460-G2 ื”ื ืกื“ืจืช ื”ืžืชื’ื™ื ื”ืฆืขื™ืจื” ื‘ื™ื•ืชืจ ืขื ื™ื›ื•ืœืช ืœื”ืฉืชืžืฉ ื‘ื™ืฆื™ืื•ืช QSFP+. ืกื“ืจื” ื–ื• ืžืื•ืคื™ื™ื ืช ื‘:

  • ื ื•ื›ื—ื•ืชื ืฉืœ ืžืกืคืจ ืจื‘ ืฉืœ ื“ื’ืžื™ื ืขื ืกื˜ื™ื ื’ืžื™ืฉื™ื ืฉืœ ื™ืฆื™ืื•ืช ืฉื•ื ื•ืช
  • ื ื•ื›ื—ื•ืช ืฉืœ ื—ืจื™ืฅ VIM ื ืคืจื“ ืœืฉื™ืžื•ืฉ ื‘ืžื•ื“ื•ืœื™ VIM ื ื•ืกืคื™ื ืขื ื™ืฆื™ืื•ืช - SFP+, QSFP+, ื™ืฆื™ืื•ืช ืขืจื™ืžื”
  • ืชืžื™ื›ื” ื‘ื—ืœืง ืžื”ื“ื’ืžื™ื ืฉืœ ืชืงืŸ 2.5GBASE-T (802.3bz).
  • ืชืžื™ื›ื” ื‘-MPLS
  • ืชืžื™ื›ื” ื‘ืชืงืŸ Ethernet ืกื™ื ื›ืจื•ื ื™ ื•ื‘ืžื•ื“ื•ืœ TM-CLK
  • ื”ื™ื›ื•ืœืช ืœืฆื™ื™ื“ ืืช ื›ืœ ื“ื’ืžื™ ื”ืžืชื’ื™ื ื‘ืกืคืงื™ ื›ื•ื— ื ื•ืกืคื™ื

ื ื™ืชืŸ ืœืจืื•ืช ืืช ืืคืฉืจื•ื™ื•ืช ืชืฆื•ืจืช ื”ื—ื•ืžืจื” ืขื‘ื•ืจ ืžืชื’ื™ื ื‘ืกื“ืจื” ื–ื• ืžื”ื˜ื‘ืœื” ื”ื‘ืื”:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
* ืžืชื’ื™ื ื‘ืกื“ืจื” ื–ื• ืžืกื•ืคืงื™ื ืœืœื ืกืคืงื™ ื›ื•ื—, ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจื™ื ื•ืžื•ื“ื•ืœ VIM. ื™ืฉ ืœื”ื–ืžื™ืŸ ืื•ืชื ื‘ื ืคืจื“.
** ืชื•ืื ืœืกื“ืจื•ืช X440, X460, X460-G2 ื•-X480, ื›ืœ ื”ืžืชื’ื™ื ื—ื™ื™ื‘ื™ื ืœื”ื™ื•ืช ืขื ืื•ืชื” ื’ืจืกืช ืชื•ื›ื ื”
*** ืชื•ืื ืœืกื“ืจื•ืช X440, X440-G2, X450, X450-G2, X460, X460-G2, X480, X670, X670V, X670-G2 ื•-X770, ื›ืœ ื”ืžืชื’ื™ื ื—ื™ื™ื‘ื™ื ืœื”ื™ื•ืช ื‘ืขืœื™ ืื•ืชื” ื’ืจืกืช ืชื•ื›ื ื”
**** ืชื•ืื ืœืกื“ืจื•ืช X460-G2, X480, X670V, X670-G2 ื•-X770, ื›ืœ ื”ืžืชื’ื™ื ื—ื™ื™ื‘ื™ื ืœื”ื™ื•ืช ืขื ืื•ืชื” ื’ืจืกืช ืชื•ื›ื ื”

ื™ืฉื ื 2 ืกื•ื’ื™ื ืฉืœ ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจื™ื ื–ืžื™ื ื™ื - ื—ื–ื™ืช ืœืื—ื•ืจ ื•ืžืื—ื•ืจ ืœื—ื–ื™ืช, ื›ืš ืฉื ื™ืชืŸ ืœื‘ื—ื•ืจ ื“ื’ื ืงื™ืจื•ืจ ื”ืขื•ื ื” ืขืœ ื”ื“ืจื™ืฉื•ืช ืœืžื™ืงื•ื ืžืขื‘ืจื™ื ื—ืžื™ื ื•ืงืจื™ื ื‘ื—ื“ืจื™ ืฉืจืชื™ื.

ื ื™ืชืŸ ืœื‘ื—ื•ืจ ืžื•ื“ื•ืœื™ VIM ืœื”ืจื—ื‘ืช ื™ืฆื™ืื•ืช, ื›ืžื• ื’ื ืจื™ืฉื™ื•ื ื•ืช ื–ืžื™ื ื™ื ืขื‘ื•ืจ ืžืชื’ื™ื ืžืกื“ืจืช X460-G2, ืžื”ื˜ื‘ืœื” ืฉืœื”ืœืŸ:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื•ื‘ืกื•ืฃ ื”ืกืงื™ืจื” ืฉืœ ื”ืกื“ืจื” ื”ื–ื•, ืืชืŸ ื›ืžื” ืชืžื•ื ื•ืช ืฉืœ ืžืชื’ื™ื:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืกื“ืจืช X620-G2

ืžืชื’ื™ ืกื“ืจืช X620-G2 ื”ื ืžืชื’ื™ 10 GE ืงื•ืžืคืงื˜ื™ื™ื ืขื ืกื˜ ืงื‘ื•ืข ืฉืœ ื™ืฆื™ืื•ืช. ื–ืžื™ืŸ ืœื”ื–ืžื ื” ืขื 2 ืกื•ื’ื™ ืจื™ืฉื™ื•ื ื•ืช - Edge License ื•-Adged Edge License.

ืชื•ืžืš ื‘ืขืจื™ืžื” ื‘ืืžืฆืขื•ืช ื˜ื›ื ื•ืœื•ื’ื™ื™ืช SummitStack-V ืขื ืกื“ืจืช ื”ืžืชื’ื™ื ื”ื‘ืื” - X440-G2, X450-G2, X460-G2, X670-G2 ื•-X770 ื‘ืืžืฆืขื•ืช 2x10 GE SFP+ ื™ืฆื™ืื•ืช ื ืชื•ื ื™ื/ืขืจื™ืžื” ื“ื•-ืชื›ืœื™ืชื™ื•ืช.

ื”ื“ื’ื ืขื ื™ืฆื™ืื•ืช PoE+ ืชื•ืžืš 60W 802.3bt 4-Pir PoE++ - Type 3 PSE. ื›ืœ ื”ื“ื’ืžื™ื ืชื•ืžื›ื™ื ื‘ื™ื›ื•ืœืช ืœื”ืชืงื™ืŸ ืกืคืงื™ ื›ื•ื— ื ื•ืกืคื™ื.

ื”ื˜ื‘ืœื” ืฉืœื”ืœืŸ ืžืฆื™ื’ื” ืืช ืชืฆื•ืจื•ืช ื”ื—ื•ืžืจื” ื”ืืคืฉืจื™ื•ืช ืขื‘ื•ืจ ื”ืกื“ืจื”:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืžืกืคืจ ืกื•ื’ื™ื ืฉืœ ืจื™ืฉื™ื•ื ื•ืช ื–ืžื™ื ื™ื ืœื”ื–ืžื ื” ืขื ืžืชื’ื™ื:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืืฆืจืฃ ื’ื ื›ืžื” ืชืžื•ื ื•ืช ืฉืœ ืžืชื’ื™ื ืœืขื™ื•ื ืš:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืกื“ืจืช X670-G2

ืžืชื’ื™ ืกื“ืจืช X670-G2 ื”ื ืžืชื’ื™ ืฆื‘ื™ืจื” ืื• ืœื™ื‘ื” 1RU ื‘ืขืœื™ ื‘ื™ืฆื•ืขื™ื ื’ื‘ื•ื”ื™ื ืขื ืฆืคื™ืคื•ืช ื™ืฆื™ืื” ื’ื‘ื•ื”ื”, ื•ื™ื›ื•ืœื™ื ืœืฉืžืฉ ื’ื ื›-Controller Bridge ืขื‘ื•ืจ ืžืชื’ื™ V400. ืžืชื’ื™ื ืขื 48 ื•-72 ืงื‘ื•ืขื™ื ืฉืœ 10 ื™ืฆื™ืื•ืช GE SFP+ ื•-4 ื™ืฆื™ืื•ืช QSFP+ ื–ืžื™ื ื™ื ืœื”ื–ืžื ื”.

ืžืชื’ื™ื ืืœื• ืžื’ื™ืขื™ื ืขื 2 ืกื•ื’ื™ ืจื™ืฉื™ื•ื ื•ืช - Advanced Edge License (ื›ืจื™ืฉื™ื•ืŸ ืจืืฉื•ื ื™) ื•-Core License ื•ืชื•ืžื›ื™ื ื‘-4 ืฉื™ื˜ื•ืช ืขืจื™ืžื” ืฉื•ื ื•ืช - SummitStack-V, Summit-Stack-80, SummitStack-160, SummitStack-320.

ืขื‘ื•ืจ ืกืคืงื™ ืื™ื ื˜ืจื ื˜ ื’ื“ื•ืœื™ื ื•ืืจื’ื•ื ื™ื ื’ื“ื•ืœื™ื ืžืื•ื“, MPLS Feature Pack ื™ืขื ื™ื™ืŸ ืื•ืชืš, ื”ืžืืคืฉืจ ืœืš ืœื”ืจื—ื™ื‘ ืืช ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ื•ืœื”ืฉืชืžืฉ ื‘ืžืชื’ื™ื ื›ื ืชื‘ื™ ืœื™ื‘ื” ืฉืœ LSR ืื• LER ื•ืœื”ืฉืชืžืฉ ื‘ื”ื ืœื‘ื ื™ื™ืช ืจืฉืชื•ืช ืžืจื•ื‘ื•ืช ืฉื™ืจื•ืชื™ื ืขื ืชืžื™ื›ื” ืขื‘ื•ืจ - L2VPN (VPLS /VPWS), L3VPNS ืžื‘ื•ืกืก BGP, LSP ืžื‘ื•ืกืก ืขืœ ืคืจื•ื˜ื•ืงื•ืœ LDP, RSVP-TE, ื”ืงืฆืื” ืกื˜ื˜ื™ืช ื•ื›ืœื™ื ืฉื•ื ื™ื ื›ื’ื•ืŸ VCCV, BFD ื•-CFM.

ืžืชื’ื™ื ื–ืžื™ื ื™ื ืœื”ื–ืžื ื” ื‘-2 ืชืฆื•ืจื•ืช:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

*ืขืจื™ืžื” ืชื•ืืžืช ืœืกื“ืจื•ืช - X440, X440-G2, X450, X450-G2, X460, X460-G2, X480, X670, X670V ื•-X770

ื”ืžืชื’ื™ื ืžืกื•ืคืงื™ื ืœืœื ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจื™ื ื•ืกืคืงื™ ื›ื•ื— - ื™ืฉ ืœื”ื–ืžื™ืŸ ืื•ืชื ื‘ื ืคืจื“. ืชื ืื™ื ื‘ืกื™ืกื™ื™ื ื‘ืขืช ื”ื‘ื—ื™ืจื”:

  • ื™ืฉ ืœื”ืชืงื™ืŸ ืกื˜ ืฉืœื ืฉืœ ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจ - 5 ื—ืœืงื™ื.
  • ืกืคืงื™ ื›ื•ื— ื•ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจื™ื ืฆืจื™ื›ื™ื ืœื”ื™ื•ืช ื‘ื’ื•ื“ืœ ื›ื“ื™ ืœืฉืžื•ืจ ืขืœ ื–ืจื™ืžืช ื”ืื•ื•ื™ืจ ื‘ืื•ืชื• ื›ื™ื•ื•ืŸ

ื”ืจื™ืฉื™ื•ื ื•ืช ื”ื‘ืื™ื ื–ืžื™ื ื™ื ืœื”ื–ืžื ื” ืขื ืžืชื’ื™ื ืžืกื“ืจื” ื–ื•:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื•ื‘ืกื•ืฃ ื”ืกืงื™ืจื” ืฉืœ ื”ืกื“ืจื” ื”ื–ื•, ืืชืŸ 2 ืชืžื•ื ื•ืช ืฉืœ ืžืชื’ื™ื:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืกื“ืจืช X590

ืœืžืชื’ื™ ื”ืกื“ืจื” ื™ืฉ ื™ืฆื™ืื•ืช 1GE/10GE/25GE/40GE/50GE/100GE ืžื•ื‘ื ื•ืช ื•ื”ื ืžื™ื•ืขื“ื™ื ืœืฉื™ืžื•ืฉ ื›:

  • ืžืชื’ื™ ืœื™ื‘ื” ืื• ืฆื‘ื™ืจื”
  • ืžืชื’ื™ Controller Bridge ื‘ืฉื™ืœื•ื‘ ืขื ืžืชื’ื™ ื’ื™ืฉื” V400
  • ืžืชื’ื™ ืžืจื›ื– ื ืชื•ื ื™ื ืžื”ืจืืฉื•ืŸ

ื”ืžืชื’ื™ื ืžืกื•ืคืงื™ื ื‘-2 ืกื•ื’ื™ื - ืขื ื™ืฆื™ืื•ืช SFP ื•-BASE-T ื•ืืคืฉืจื•ืช ืœ-2 ืกืคืงื™ ื›ื•ื—:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

* ืชื•ืื ืœืกื“ืจื•ืช X690 ื•-X870.

ื”ืžืชื’ื™ื ืžืกื•ืคืงื™ื ืœืœื ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจื™ื ื•ืกืคืงื™ ื›ื•ื— - ื™ืฉ ืœื”ื–ืžื™ืŸ ืื•ืชื ื‘ื ืคืจื“. ื”ืชื ืื™ื ื”ืขื™ืงืจื™ื™ื ืœื‘ื—ื™ืจืชื ื”ื ื›ื“ืœืงืžืŸ:

  • ื™ืฉ ืœื”ืชืงื™ืŸ ืกื˜ ืฉืœื ืฉืœ ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจ - 4 ื—ืœืงื™ื.
  • ืกืคืงื™ ื›ื•ื— ื•ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจื™ื ืฆืจื™ื›ื™ื ืœื”ื™ื•ืช ื‘ื’ื•ื“ืœ ื›ื“ื™ ืœืฉืžื•ืจ ืขืœ ื–ืจื™ืžืช ื”ืื•ื•ื™ืจ ื‘ืื•ืชื• ื›ื™ื•ื•ืŸ
  • ืœื ื ื™ืชืŸ ืœื”ืชืงื™ืŸ ื‘ืžืชื’ ืกืคืงื™ ื›ื•ื— AC ื•-DC ื‘ื•-ื–ืžื ื™ืช

ืจื™ืฉื™ื•ื ื•ืช ื–ืžื™ื ื™ื ืœื”ื–ืžื ื” ืขื ืžืชื’ื™ื ืืœื”:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื”ืชืžื•ื ื•ืช ืฉืœ ื”ืžืชื’ื™ื ืžื•ืฆื’ื•ืช ื‘ืื™ื•ืจ ืฉืœื”ืœืŸ:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืกื“ืจืช X690

ืœืžืชื’ื™ ื”ืกื“ืจื” ื™ืฉ ื™ื•ืชืจ ื™ืฆื™ืื•ืช 1GE/10GE/25GE/40GE/50GE/100GE ืžื•ื‘ื ื•ืช ื‘ื”ืฉื•ื•ืื” ืœืกื“ืจืช X590 ื•ื”ื ืžื™ื•ืขื“ื™ื ื’ื ืœืฉืžืฉ:

  • ืžืชื’ื™ ืœื™ื‘ื” ืื• ืฆื‘ื™ืจื”
  • ืžืชื’ื™ Controller Bridge ื‘ืฉื™ืœื•ื‘ ืขื ืžืชื’ื™ ื’ื™ืฉื” V400
  • ืžืชื’ื™ ืžืจื›ื– ื ืชื•ื ื™ื ืžื”ืจืืฉื•ืŸ

ืžืชื’ื™ ื”ืกื“ืจื” ื–ืžื™ื ื™ื ื’ื ื‘-2 ืกื•ื’ื™ื - ืขื ื™ืฆื™ืื•ืช SFP ื•-BASE-T ื•ืืคืฉืจื•ืช ืœ-2 ืกืคืงื™ ื›ื•ื—:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

* ืชื•ืื ืœืกื“ืจื•ืช X590 ื•-X870.
ื”ืžืชื’ื™ื ืžืกื•ืคืงื™ื ืœืœื ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจื™ื ื•ืกืคืงื™ ื›ื•ื— - ื™ืฉ ืœื”ื–ืžื™ืŸ ืื•ืชื ื‘ื ืคืจื“. ื”ืชื ืื™ื ื”ืขื™ืงืจื™ื™ื ืœื‘ื—ื™ืจืชื ื”ื ื›ื“ืœืงืžืŸ:

  • ื™ืฉ ืœื”ืชืงื™ืŸ ืกื˜ ืฉืœื ืฉืœ ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจ - 6 ื—ืœืงื™ื
  • ืกืคืงื™ ื›ื•ื— ื•ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจื™ื ืฆืจื™ื›ื™ื ืœื”ื™ื•ืช ื‘ื’ื•ื“ืœ ื›ื“ื™ ืœืฉืžื•ืจ ืขืœ ื–ืจื™ืžืช ื”ืื•ื•ื™ืจ ื‘ืื•ืชื• ื›ื™ื•ื•ืŸ
  • ืœื ื ื™ืชืŸ ืœื”ืชืงื™ืŸ ื‘ืžืชื’ ืกืคืงื™ ื›ื•ื— AC ื•-DC ื‘ื•-ื–ืžื ื™ืช

ืจื™ืฉื™ื•ื ื•ืช ื–ืžื™ื ื™ื ืœื”ื–ืžื ื” ืขื ืžืชื’ื™ื ืืœื”:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ื”ืชืžื•ื ื•ืช ืฉืœ ื”ืžืชื’ื™ื ืžื•ืฆื’ื•ืช ื‘ืื™ื•ืจ ืฉืœื”ืœืŸ:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืกื“ืจืช X870

ืžืฉืคื—ืช X870 ื”ื™ื ืžืชื’ 100Gb ื‘ืฆืคื™ืคื•ืช ื’ื‘ื•ื”ื” ื•ื ื™ืชืŸ ืœื”ืฉืชืžืฉ ื‘ื• ื›ืžืชื’ื™ ืœื™ื‘ื” ืืจื’ื•ื ื™ื™ื ื‘ืขืœื™ ื‘ื™ืฆื•ืขื™ื ื’ื‘ื•ื”ื™ื ื•ืžืชื’ื™ ืžืจื›ื– ื ืชื•ื ื™ื ื‘ืฉื“ืจื”/ืขืœื™ื.

ืžื™ืชื•ื’ ืขื ืื—ื–ื•ืจ ื ืžื•ืš ื•ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืžืชืงื“ืžืช ืฉืœ ืจื™ืฉื™ื•ืŸ ืœื™ื‘ื” ื•-MPLS ื”ื•ืคื›ื™ื ืื•ืชื ืœืื™ื“ื™ืืœื™ื™ื ืœืฉื™ืžื•ืฉ ื‘ื™ื™ืฉื•ืžื™ ืžืจื›ื– ื ืชื•ื ื™ื ื‘ืขืœื™ ื‘ื™ืฆื•ืขื™ื ื’ื‘ื•ื”ื™ื. 
ืžืชื’ x870-96x-8c-Base ืžื™ื™ืฉื ื’ื ืืช ืื™ื“ื™ืื•ืœื•ื’ื™ื™ืช "ืฉืœื-ื›ืคื™-ืชื’ื“ืœ" - ื”ื•ื ืžื•ืจื›ื‘ ืžื”ื™ื›ื•ืœืช ืœื”ืจื—ื™ื‘ ืืช ืชืคื•ืงืช ื”ืคื•ืจื˜ื™ื ื‘ืืžืฆืขื•ืช ืจื™ืฉื™ื•ื ื•ืช ืฉื“ืจื•ื’ (ื”ืจื™ืฉื™ื•ืŸ ืžื•ื—ืœ ืขืœ ืงื‘ื•ืฆื•ืช ืฉืœ 6 ื™ืฆื™ืื•ืช, ืขื“ 4 ืจื™ืฉื™ื•ื ื•ืช).

ื”ืžืชื’ื™ื ืžืกื•ืคืงื™ื ื‘-2 ืชืฆื•ืจื•ืช ื•ืžืฆื•ื™ื“ื™ื ื‘-2 ืกืคืงื™ ื›ื•ื—:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme
* ืชื•ืื ืœืกื“ืจื•ืช X590 ื•-X690.
ื”ืžืชื’ื™ื ืžืกื•ืคืงื™ื ืœืœื ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจื™ื ื•ืกืคืงื™ ื›ื•ื— - ื™ืฉ ืœื”ื–ืžื™ืŸ ืื•ืชื ื‘ื ืคืจื“. ื”ืชื ืื™ื ื”ืขื™ืงืจื™ื™ื ืœื‘ื—ื™ืจืชื ื”ื ื›ื“ืœืงืžืŸ:

  • ื™ืฉ ืœื”ืชืงื™ืŸ ืกื˜ ืฉืœื ืฉืœ ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจ - 6 ื—ืœืงื™ื
  • ืกืคืงื™ ื›ื•ื— ื•ืžื•ื“ื•ืœื™ ืžืื•ื•ืจืจื™ื ืฆืจื™ื›ื™ื ืœื”ื™ื•ืช ื‘ื’ื•ื“ืœ ื›ื“ื™ ืœืฉืžื•ืจ ืขืœ ื–ืจื™ืžืช ื”ืื•ื•ื™ืจ ื‘ืื•ืชื• ื›ื™ื•ื•ืŸ
  • ืœื ื ื™ืชืŸ ืœื”ืชืงื™ืŸ ื‘ืžืชื’ ืกืคืงื™ ื›ื•ื— AC ื•-DC ื‘ื•-ื–ืžื ื™ืช

ื”ืจื™ืฉื™ื•ื ื•ืช ื”ื–ืžื™ื ื™ื ืœืจื›ื™ืฉื” ืขื ืžืชื’ื™ื ืืœื” ื”ื ื›ื“ืœืงืžืŸ:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืžืชื’ื™ื ืžืฉื ื™ ืกื•ื’ื™ื ื ืจืื™ื ื–ื”ื™ื ืœื—ืœื•ื˜ื™ืŸ, ื›ืคื™ ืฉืžื•ืฆื’ ื‘ืชืžื•ื ื” ืœืžื˜ื”:

1. ืกืงื™ืจื” ื›ืœืœื™ืช ืฉืœ ืžืชื’ื™ื ื‘ืจืžืช Enterprise Extreme

ืžืกืงื ื”

ื—ื‘ืจื™ื, ืื ื™ ืจื•ืฆื” ืœืกื™ื™ื ืืช ืžืืžืจ ื”ื‘ื™ืงื•ืจืช ื”ื–ื” ื‘ืกื“ืจื” ื”ื–ื• ื›ื“ื™ ืœื ืœื ืคื— ืื•ืชื” ืœืจืžื” ืขื ืงื™ืช, ื•ื‘ื›ืš ืœืกื‘ืš ืืช ื”ืงืจื™ืื” ื•ื”ืชืคื™ืกื” ืฉืœื”.

ืื ื™ ื—ื™ื™ื‘ ืœื•ืžืจ ืฉืœ-ExtremeNetworks ื™ืฉ ื”ืจื‘ื” ื™ื•ืชืจ ืกื•ื’ื™ื ืฉืœ ืžืชื’ื™ื:

  • ืืœื” ื”ื ื“ื’ืžื™ VSP (Virtual Services Platform), ืฉื—ืœืงื ื”ื ืžืชื’ื™ื ืžื•ื“ื•ืœืจื™ื™ื ืขื ื™ื›ื•ืœืช ืœื”ื’ื“ื™ืจ ืื•ืชื ืขื ืกื˜ื™ื ืฉื•ื ื™ื ืฉืœ ื™ืฆื™ืื•ืช
  • ืืœื• ื”ื ืžืชื’ื™ื ืžืกื“ืจื•ืช VDX ื•-SLX, ื”ืžืชืžื—ื™ื ืœืขื‘ื•ื“ื” ื‘ืžืจื›ื–ื™ ื ืชื•ื ื™ื

ื‘ืขืชื™ื“, ืื ืกื” ืœืชืืจ ืืช ื”ืžืชื’ื™ื ืœืขื™ืœ ื•ืืช ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ืฉืœื”ื, ืืš ืกื‘ื™ืจ ืœื”ื ื™ื— ืฉื–ื” ื™ื”ื™ื” ืžืืžืจ ื ื•ืกืฃ.

ืœื‘ืกื•ืฃ, ืื ื™ ืจื•ืฆื” ืœื”ื–ื›ื™ืจ ืขื•ื“ ื“ื‘ืจ ื—ืฉื•ื‘ - ืœื ืฆื™ื™ื ืชื™ ืื•ืชื• ื‘ืฉื•ื ืžืงื•ื ื‘ืžืืžืจ, ืื‘ืœ ืžืชื’ื™ ืืงืกื˜ืจื™ื ืชื•ืžื›ื™ื ื‘-SFP/SFP BASE-T/SFP+/QSFP/QSFP+ ืžื™ืฆืจื ื™ ืฆื“ ืฉืœื™ืฉื™, ืœืœื ืฉื•ื ื˜ื›ื ื™ืช ืื• ื—ื•ืงื™ืช ื”ื’ื‘ืœื•ืช (ื›ื’ื•ืŸ, ืœืžืฉืœ, ืกื™ืกืงื•) ืฉื™ืžื•ืฉ ื‘ืžื•ื“ื•ืœื™ื ืฉืœ ืฆื“ ืฉืœื™ืฉื™, ืœื - ืื ืžืงืœื˜ ื”ืžืฉื“ืจ ื”ื•ื ื‘ืื™ื›ื•ืช ื’ื‘ื•ื”ื” ื•ื”ื•ื ืžื–ื•ื”ื” ืขืœ ื™ื“ื™ ื”ืžืชื’, ืื– ื–ื” ื™ืขื‘ื•ื“.

ืชื•ื“ื” ืขืœ ืชืฉื•ืžืช ื”ืœื‘ ื•ื ืชืจืื” ื‘ืžืืžืจื™ื ื”ื‘ืื™ื. ื•ื›ื“ื™ ืœื ืœืคืกืคืก ืื•ืชื, ืœื”ืœืŸ ื”"ืฆื™ื‘ื•ืจื™ื" ืฉืœื ื• ืฉื‘ื”ื ืชื•ื›ืœื• ืœืขืงื•ื‘ ืื—ืจ ื”ื•ืคืขืช ื—ื•ืžืจื™ื ื—ื“ืฉื™ื:
- ืžื‘ืจืง
- ืคื™ื™ืกื‘ื•ืง
- VK
- ื‘ืœื•ื’ ืคืชืจื•ื ื•ืช TS

ืžืงื•ืจ: www.habr.com

ื”ื•ืกืคืช ืชื’ื•ื‘ื”