ืื“ืžื™ืŸ ืœืœื ื™ื“ื™ื™ื = ื”ื™ืคืจ ื”ืชื›ื ืกื•ืช?

ืื“ืžื™ืŸ ืœืœื ื™ื“ื™ื™ื = ื”ื™ืคืจ ื”ืชื›ื ืกื•ืช?
ืื“ืžื™ืŸ ืœืœื ื™ื“ื™ื™ื = ื”ื™ืคืจ ื”ืชื›ื ืกื•ืช?

ื–ื”ื• ืžื™ืชื•ืก ื ืคื•ืฅ ืœืžื“ื™ ื‘ืชื—ื•ื ื—ื•ืžืจืช ื”ืฉืจืชื™ื. ื‘ืคื•ืขืœ, ื™ืฉ ืฆื•ืจืš ื‘ืคืชืจื•ื ื•ืช ื”ื™ืคืจ-ืงื•ื ื‘ืจื–ืฆื™ื” (ื›ืฉื”ื›ืœ ื‘ืื—ื“) ืœื“ื‘ืจื™ื ืจื‘ื™ื. ืžื‘ื—ื™ื ื” ื”ื™ืกื˜ื•ืจื™ืช, ื”ืืจื›ื™ื˜ืงื˜ื•ืจื•ืช ื”ืจืืฉื•ื ื•ืช ืคื•ืชื—ื• ืขืœ ื™ื“ื™ ืืžื–ื•ืŸ ื•ื’ื•ื’ืœ ืขื‘ื•ืจ ื”ืฉื™ืจื•ืชื™ื ืฉืœื”ืŸ. ื•ืื– ื”ืจืขื™ื•ืŸ ื”ื™ื” ืœื™ืฆื•ืจ ื—ื•ื•ืช ืžื—ืฉื•ื‘ ืžืฆืžืชื™ื ื–ื”ื™ื, ืฉืœื›ืœ ืื—ื“ ืžื”ื ื™ืฉ ื“ื™ืกืงื™ื ืžืฉืœื•. ื›ืœ ื–ื” ืื•ื—ื“ ืขืœ ื™ื“ื™ ืชื•ื›ื ื” ืœื™ืฆื™ืจืช ืžืขืจื›ืช (hypervisor) ื•ื—ื•ืœืง ืœืžื›ื•ื ื•ืช ื•ื™ืจื˜ื•ืืœื™ื•ืช. ื”ืžื˜ืจื” ื”ืขื™ืงืจื™ืช ื”ื™ื ืžื™ื ื™ืžื•ื ืžืืžืฅ ืœืฉื™ืจื•ืช ืฆื•ืžืช ืื—ื“ ื•ืžื™ื ื™ืžื•ื ื‘ืขื™ื•ืช ื‘ืขืช ืงื ื” ืžื™ื“ื”: ืคืฉื•ื˜ ืงื ื” ืขื•ื“ ืืœืฃ ืื• ืฉื ื™ื™ื ืžืื•ืชื ืฉืจืชื™ื ื•ื—ื‘ืจ ืื•ืชื ื‘ืงืจื‘ืช ืžืงื•ื. ื‘ืคื•ืขืœ, ืžื“ื•ื‘ืจ ื‘ืžืงืจื™ื ื‘ื•ื“ื“ื™ื, ื•ืœืขืชื™ื ืงืจื•ื‘ื•ืช ื”ืจื‘ื” ื™ื•ืชืจ ืžื“ื‘ืจื™ื ืขืœ ืžืกืคืจ ืงื˜ืŸ ื™ื•ืชืจ ืฉืœ ืฆืžืชื™ื ื•ืืจื›ื™ื˜ืงื˜ื•ืจื” ืžืขื˜ ืฉื•ื ื”.

ืื‘ืœ ื”ื™ืชืจื•ืŸ ื ืฉืืจ ื–ื”ื” - ืงืœื•ืช ืงื ื” ืžื™ื“ื” ื•ื ื™ื”ื•ืœ ืžื“ื”ื™ืžื”. ื”ื—ื™ืกืจื•ืŸ ื”ื•ื ืฉืžืฉื™ืžื•ืช ืฉื•ื ื•ืช ืฆื•ืจื›ื•ืช ืžืฉืื‘ื™ื ื‘ืฆื•ืจื” ืฉื•ื ื”, ื•ื‘ืžืงื•ืžื•ืช ืžืกื•ื™ืžื™ื ื™ื”ื™ื• ื”ืจื‘ื” ื“ื™ืกืงื™ื ืžืงื•ืžื™ื™ื, ื‘ืื—ืจื™ื ื™ื”ื™ื” ืžืขื˜ ื–ื™ื›ืจื•ืŸ RAM ื•ื›ืŸ ื”ืœืื”, ื›ืœื•ืžืจ ืขื‘ื•ืจ ืกื•ื’ื™ื ืฉื•ื ื™ื ืฉืœ ืžืฉื™ืžื•ืช, ื ื™ืฆื•ืœ ื”ืžืฉืื‘ื™ื ืชืงื˜ืŸ.

ืžืกืชื‘ืจ ืฉืืชื” ืžืฉืœื 10-15% ื™ื•ืชืจ ืขื‘ื•ืจ ืงืœื•ืช ื”ื”ืชืงื ื”. ื–ื” ืžื” ืฉื”ืฆื™ืช ืืช ื”ืžื™ืชื•ืก ื‘ื›ื•ืชืจืช. ื—ื™ืคืฉื ื• ื–ืžืŸ ืจื‘ ื”ื™ื›ืŸ ื”ื˜ื›ื ื•ืœื•ื’ื™ื” ืชื™ื•ืฉื ื‘ืฆื•ืจื” ืžื™ื˜ื‘ื™ืช, ื•ืžืฆืื ื• ืื•ืชื”. ื”ืขื•ื‘ื“ื” ื”ื™ื ืฉืœืกื™ืกืงื• ืœื ื”ื™ื• ืžืขืจื›ื•ืช ืื—ืกื•ืŸ ืžืฉืœื”, ืื‘ืœ ื”ื ืจืฆื• ืฉื•ืง ืฉืจืชื™ื ืฉืœื. ื•ื”ื ื™ืฆืจื• ืืช Cisco Hyperflex - ืคืชืจื•ืŸ ืขื ืื—ืกื•ืŸ ืžืงื•ืžื™ ื‘ืฆืžืชื™ื.

ื•ื–ื” ืคืชืื•ื ื”ืชื‘ืจืจ ื›ืคืชืจื•ืŸ ื˜ื•ื‘ ืžืื•ื“ ืœื’ื™ื‘ื•ื™ ืžืจื›ื–ื™ ื ืชื•ื ื™ื (Disaster Recovery). ืื ื™ ืื’ื™ื“ ืœืš ืœืžื” ื•ืื™ืš ืขื›ืฉื™ื•. ื•ืื ื™ ืืจืื” ืœืš ืืช ืžื‘ื—ื ื™ ื”ืืฉื›ื•ืœ.

ื”ื™ื›ืŸ ืฉืฆืจื™ืš

ื”ื™ืคืจืงื•ื ื‘ืจื’ื ืฆื™ื” ื”ื™ื:

  1. ื”ืขื‘ืจืช ื“ื™ืกืงื™ื ืœืฆืžืชื™ ืžื—ืฉื•ื‘.
  2. ืื™ื ื˜ื’ืจืฆื™ื” ืžืœืื” ืฉืœ ืชืช-ืžืขืจื›ืช ื”ืื—ืกื•ืŸ ืขื ืชืช-ืžืขืจื›ืช ื”ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื”.
  3. ื”ืขื‘ืจื”/ืื™ื ื˜ื’ืจืฆื™ื” ืขื ืชืช-ืžืขืจื›ืช ื”ืจืฉืช.

ืฉื™ืœื•ื‘ ื–ื” ืžืืคืฉืจ ืœืš ืœื™ื™ืฉื ืชื›ื•ื ื•ืช ืจื‘ื•ืช ืฉืœ ืžืขืจื›ืช ื”ืื—ืกื•ืŸ ื‘ืจืžืช ื”ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื” ื•ื”ื›ืœ ืžื—ืœื•ืŸ ื‘ืงืจื” ืื—ื“.

ื‘ื—ื‘ืจื” ืฉืœื ื• ื™ืฉ ื‘ื™ืงื•ืฉ ืจื‘ ืœืคืจื•ื™ืงื˜ื™ื ืœืชื›ื ื•ืŸ ืžืจื›ื–ื™ ื ืชื•ื ื™ื ืžื™ื•ืชืจื™ื, ื•ืœืขื™ืชื™ื ืงืจื•ื‘ื•ืช ื ื‘ื—ืจ ืคืชืจื•ืŸ ื”ื™ืคืจ-ืงื•ื ื‘ืจื–ืฆื™ื” ื‘ื’ืœืœ ืฉืœืœ ืืคืฉืจื•ื™ื•ืช ืฉื›ืคื•ืœ (ืขื“ ืžื˜ืจื•ืงืœืกื˜ืจ) ืžื—ื•ืฅ ืœืงื•ืคืกื”.

ื‘ืžืงืจื” ืฉืœ ื’ื™ื‘ื•ื™ ืžืจื›ื–ื™ ื ืชื•ื ื™ื, ืื ื—ื ื• ืžื“ื‘ืจื™ื ื‘ื“ืจืš ื›ืœืœ ืขืœ ืžืชืงืŸ ืžืจื•ื—ืง ื‘ืืชืจ ื‘ืฆื“ ื”ืฉื ื™ ืฉืœ ื”ืขื™ืจ ืื• ื‘ื›ืœืœ ื‘ืขื™ืจ ืื—ืจืช. ื–ื” ืžืืคืฉืจ ืœืš ืœืฉื—ื–ืจ ืžืขืจื›ื•ืช ืงืจื™ื˜ื™ื•ืช ื‘ืžืงืจื” ืฉืœ ื›ืฉืœ ื—ืœืงื™ ืื• ืžืœื ืฉืœ ืžืจื›ื– ื”ื ืชื•ื ื™ื ื”ืจืืฉื™. ื ืชื•ื ื™ ืžื›ื™ืจื•ืช ืžืฉื•ื›ืคืœื™ื ืฉื ื›ืœ ื”ื–ืžืŸ, ื•ื”ืฉื›ืคื•ืœ ื”ื–ื” ื™ื›ื•ืœ ืœื”ื™ื•ืช ื‘ืจืžืช ื”ืืคืœื™ืงืฆื™ื” ืื• ื‘ืจืžืช ื”ืชืงืŸ ื”ื—ืกื™ืžื” (ืื—ืกื•ืŸ).

ืœื›ืŸ, ืขื›ืฉื™ื• ืื“ื‘ืจ ืขืœ ืขื™ืฆื•ื‘ ื”ืžืขืจื›ืช ื•ื‘ื“ื™ืงื•ืช, ื•ืœืื—ืจ ืžื›ืŸ ืขืœ ื›ืžื” ืชืจื—ื™ืฉื™ ื™ื™ืฉื•ืžื™ื ืืžื™ืชื™ื™ื ืขื ื ืชื•ื ื™ ื—ื™ืกื›ื•ืŸ.

ื‘ื“ื™ืงื•ืช

ื”ืžื•ืคืข ืฉืœื ื• ืžื•ืจื›ื‘ ืžืืจื‘ืขื” ืฉืจืชื™ื, ืฉืœื›ืœ ืื—ื“ ืžื”ื 10 ื›ื•ื ื ื™ SSD ืฉืœ 960 GB. ืงื™ื™ื ื“ื™ืกืง ื™ื™ืขื•ื“ื™ ืœืื—ืกื•ืŸ ืคืขื•ืœื•ืช ื›ืชื™ื‘ื” ื‘ืžื˜ืžื•ืŸ ื•ืื—ืกื•ืŸ ื”ืžื›ื•ื ื” ื”ื•ื™ืจื˜ื•ืืœื™ืช ืฉืœ ื”ืฉื™ืจื•ืช. ื”ืคืชืจื•ืŸ ืขืฆืžื• ื”ื•ื ื”ื’ืจืกื” ื”ืจื‘ื™ืขื™ืช. ื”ืจืืฉื•ืŸ ื’ืก ืœืžืขืŸ ื”ืืžืช (ืื ืœืฉืคื•ื˜ ืœืคื™ ื”ื‘ื™ืงื•ืจื•ืช), ื”ืฉื ื™ ืœื—, ื”ืฉืœื™ืฉื™ ื›ื‘ืจ ื“ื™ ื™ืฆื™ื‘, ื•ืืคืฉืจ ืœืงืจื•ื ืœื–ื” ืฉื—ืจื•ืจ ืœืื—ืจ ืกื™ื•ื ื‘ื“ื™ืงื•ืช ื”ื‘ื˜ื ืœืงื”ืœ ื”ืจื—ื‘. ื‘ืžื”ืœืš ื”ื‘ื“ื™ืงื” ืœื ืจืื™ืชื™ ื‘ืขื™ื•ืช, ื”ื›ืœ ืขื•ื‘ื“ ื›ืžื• ืฉืขื•ืŸ.

ืฉื™ื ื•ื™ื™ื ื‘-v4ื—ื‘ื•ืจื” ืฉืœ ื‘ืื’ื™ื ืชื•ืงื ื•.

ื‘ืชื—ื™ืœื”, ื”ืคืœื˜ืคื•ืจืžื” ื™ื›ืœื” ืœืขื‘ื•ื“ ืจืง ืขื ื”-VMware ESXi hypervisor ื•ืชืžื›ื” ื‘ืžืกืคืจ ืงื˜ืŸ ืฉืœ ืฆืžืชื™ื. ื›ืžื• ื›ืŸ, ืชื”ืœื™ืš ื”ืคืจื™ืกื” ืœื ืชืžื™ื“ ื”ืกืชื™ื™ื ื‘ื”ืฆืœื—ื”, ื”ื™ื” ืฆื•ืจืš ืœื”ืคืขื™ืœ ืžื—ื“ืฉ ื›ืžื” ืฉืœื‘ื™ื, ื”ื™ื• ื‘ืขื™ื•ืช ื‘ืขื“ื›ื•ืŸ ืžื’ืจืกืื•ืช ื™ืฉื ื•ืช ื™ื•ืชืจ, ื ืชื•ื ื™ื ื‘-GUI ืœื ืชืžื™ื“ ื”ื•ืฆื’ื• ื‘ืฆื•ืจื” ื ื›ื•ื ื” (ืื ื›ื™ ืื ื™ ืขื“ื™ื™ืŸ ืœื ืžืจื•ืฆื” ืžื”ืฆื’ืช ื’ืจืคื™ ื”ื‘ื™ืฆื•ืขื™ื ), ืœืคืขืžื™ื ื”ืชืขื•ืจืจื• ื‘ืขื™ื•ืช ื‘ืžืžืฉืง ืขื ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื”.

ื›ืขืช ื›ืœ ื‘ืขื™ื•ืช ื”ื™ืœื“ื•ืช ืชื•ืงื ื•, HyperFlex ื™ื›ื•ืœ ืœื”ืชืžื•ื“ื“ ื’ื ืขื ESXi ื•ื’ื Hyper-V, ื‘ื ื•ืกืฃ ื–ื” ืืคืฉืจื™:

  1. ื™ืฆื™ืจืช ืืฉื›ื•ืœ ืžืชื•ื—.
  2. ื™ืฆื™ืจืช ืืฉื›ื•ืœ ืœืžืฉืจื“ื™ื ืœืœื ืฉื™ืžื•ืฉ ื‘- Fabric Interconnect, ืžืฉื ื™ื™ื ืขื“ ืืจื‘ืขื” ืฆืžืชื™ื (ืื ื• ืงื•ื ื™ื ืจืง ืฉืจืชื™ื).
  3. ื™ื›ื•ืœืช ืขื‘ื•ื“ื” ืขื ืžืขืจื›ื•ืช ืื—ืกื•ืŸ ื—ื™ืฆื•ื ื™ื•ืช.
  4. ืชืžื™ื›ื” ื‘ืงื•ื ื˜ื™ื™ื ืจื™ื ื•-Kubernetes.
  5. ื™ืฆื™ืจืช ืื–ื•ืจื™ ื–ืžื™ื ื•ืช.
  6. ืื™ื ื˜ื’ืจืฆื™ื” ืขื VMware SRM ืื ื”ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช ื”ืžื•ื‘ื ื™ืช ืื™ื ื” ืžืฉื‘ื™ืขืช ืจืฆื•ืŸ.

ื”ืืจื›ื™ื˜ืงื˜ื•ืจื” ืื™ื ื” ืฉื•ื ื” ื‘ื”ืจื‘ื” ืžื”ืคืชืจื•ื ื•ืช ืฉืœ ื”ืžืชื—ืจื™ื ื”ืขื™ืงืจื™ื™ื ืฉืœื”; ื”ื ืœื ื™ืฆืจื• ืื•ืคื ื™ื™ื. ื”ื›ืœ ืคื•ืขืœ ืขืœ ืคืœื˜ืคื•ืจืžืช ื”ื•ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื” ืฉืœ VMware ืื• Hyper-V. ื”ื—ื•ืžืจื” ืžืชืืจื—ืช ื‘ืฉืจืชื™ Cisco UCS ืงื ื™ื™ื ื™ื™ื. ื™ืฉ ื›ืืœื” ืฉืฉื•ื ืื™ื ืืช ื”ืคืœื˜ืคื•ืจืžื” ื‘ื’ืœืœ ื”ืžื•ืจื›ื‘ื•ืช ื”ื™ื—ืกื™ืช ืฉืœ ื”ื”ื’ื“ืจื” ื”ืจืืฉื•ื ื™ืช, ื”ืจื‘ื” ื›ืคืชื•ืจื™ื, ืžืขืจื›ืช ืœื ื˜ืจื™ื•ื•ื™ืืœื™ืช ืฉืœ ืชื‘ื ื™ื•ืช ื•ืชืœื•ืช, ืื‘ืœ ื™ืฉ ื’ื ื›ืืœื” ืฉืœืžื“ื• ื–ืŸ, ืฉื•ืื‘ื™ื ื”ืฉืจืื” ืžื”ืจืขื™ื•ืŸ ื•ืœื ืจื•ืฆื™ื ื™ื•ืชืจ. ืœืขื‘ื•ื“ ืขื ืฉืจืชื™ื ืื—ืจื™ื.

ื ืฉืงื•ืœ ืืช ื”ืคืชืจื•ืŸ ืขื‘ื•ืจ VMware, ืžื›ื™ื•ื•ืŸ ืฉื”ืคืชืจื•ืŸ ื ื•ืฆืจ ืขื‘ื•ืจื• ื‘ืžืงื•ืจ ื•ื™ืฉ ืœื• ื™ื•ืชืจ ืคื•ื ืงืฆื™ื•ื ืœื™ื•ืช; Hyper-V ื”ืชื•ื•ืกืฃ ืœืื•ืจืš ื”ื“ืจืš ืขืœ ืžื ืช ืœืขืžื•ื“ ื‘ืงืฆื‘ ืฉืœ ื”ืžืชื—ืจื™ื ื•ืœืขืžื•ื“ ื‘ืฆื™ืคื™ื•ืช ื”ืฉื•ืง.

ื™ืฉ ืืฉื›ื•ืœ ืฉืจืชื™ื ืžืœื ื‘ื“ื™ืกืงื™ื. ื™ืฉื ื ื“ื™ืกืงื™ื ืœืื—ืกื•ืŸ ื ืชื•ื ื™ื (SSD ืื• HDD - ืœืคื™ ื˜ืขืžื›ื ื•ืฆืจื›ื™ื›ื), ื™ืฉ ื“ื™ืกืง SSD ืื—ื“ ืœืื—ืกื•ืŸ ื‘ืžื˜ืžื•ืŸ. ื‘ืขืช ื›ืชื™ื‘ืช ื ืชื•ื ื™ื ืœืžืื’ืจ ื”ื ืชื•ื ื™ื, ื”ื ืชื•ื ื™ื ื ืฉืžืจื™ื ื‘ืฉื›ื‘ืช ื”ืžื˜ืžื•ืŸ (ื“ื™ืกืง SSD ื™ื™ืขื•ื“ื™ ื•-RAM ืฉืœ ื”ืฉื™ืจื•ืช VM). ื‘ืžืงื‘ื™ืœ, ื‘ืœื•ืง ื ืชื•ื ื™ื ื ืฉืœื— ืœืฆืžืชื™ื ื‘ืืฉื›ื•ืœ (ืžืกืคืจ ื”ืฆืžืชื™ื ืชืœื•ื™ ื‘ื’ื•ืจื ืฉื›ืคื•ืœ ื”ืืฉื›ื•ืœื•ืช). ืœืื—ืจ ืื™ืฉื•ืจ ืžื›ืœ ื”ืฆืžืชื™ื ืขืœ ื”ืงืœื˜ื” ืžื•ืฆืœื—ืช, ืื™ืฉื•ืจ ื”ื”ืงืœื˜ื” ื ืฉืœื— ืœ-hypervisor ื•ืœืื—ืจ ืžื›ืŸ ืœ-VM. ื”ื ืชื•ื ื™ื ื”ืžื•ืงืœื˜ื™ื ืžืฉื•ื›ืคืœื™ื, ื ื“ื—ืกื™ื ื•ื ื›ืชื‘ื™ื ืœื“ื™ืกืงื™ ืื—ืกื•ืŸ ื‘ืจืงืข. ื‘ืžืงื‘ื™ืœ, ืชืžื™ื“ ื ื›ืชื‘ ื‘ืœื•ืง ื’ื“ื•ืœ ืœื“ื™ืกืงื™ ื”ืื—ืกื•ืŸ ื•ื‘ืจืฆืฃ, ืžื” ืฉืžืคื—ื™ืช ืืช ื”ืขื•ืžืก ืขืœ ื“ื™ืกืงื™ ื”ืื—ืกื•ืŸ.

ื‘ื™ื˜ื•ืœ ื›ืคื™ืœื•ื™ื•ืช ื•ื“ื—ื™ืกื” ืžื•ืคืขืœื™ื ืชืžื™ื“ ื•ืœื ื ื™ืชืŸ ืœื‘ื˜ืœ ืื•ืชื. ื”ื ืชื•ื ื™ื ื ืงืจืื™ื ื™ืฉื™ืจื•ืช ืžื“ื™ืกืงื™ ืื—ืกื•ืŸ ืื• ืžืžื˜ืžื•ืŸ ื”-RAM. ืื ื ืขืฉื” ืฉื™ืžื•ืฉ ื‘ืชืฆื•ืจื” ื”ื™ื‘ืจื™ื“ื™ืช, ื”ืงืจื™ืื•ืช ื ืฉืžืจื•ืช ื’ื ื‘-SSD.

ื”ื ืชื•ื ื™ื ืื™ื ื ืงืฉื•ืจื™ื ืœืžื™ืงื•ื ื”ื ื•ื›ื—ื™ ืฉืœ ื”ืžื›ื•ื ื” ื”ื•ื™ืจื˜ื•ืืœื™ืช ื•ืžื—ื•ืœืงื™ื ื‘ืื•ืคืŸ ืฉื•ื•ื” ื‘ื™ืŸ ื”ืฆืžืชื™ื. ื’ื™ืฉื” ื–ื• ืžืืคืฉืจืช ืœืš ืœื˜ืขื•ืŸ ืืช ื›ืœ ื”ื“ื™ืกืงื™ื ื•ืžืžืฉืงื™ ื”ืจืฉืช ื‘ืื•ืคืŸ ืฉื•ื•ื”. ื™ืฉื ื• ื—ื™ืกืจื•ืŸ ื‘ืจื•ืจ: ืื™ื ื ื• ื™ื›ื•ืœื™ื ืœื”ืคื—ื™ืช ืืช ื–ืžืŸ ื”ืื—ื–ื•ืจ ืœืงืจื™ืื” ื›ื›ืœ ื”ืืคืฉืจ, ืžื›ื™ื•ื•ืŸ ืฉืื™ืŸ ืขืจื•ื‘ื” ืœื–ืžื™ื ื•ืช ื ืชื•ื ื™ื ืžืงื•ืžื™ืช. ืื‘ืœ ืื ื™ ืกื‘ื•ืจ ืฉืžื“ื•ื‘ืจ ื‘ื”ืงืจื‘ื” ืžื™ื ื•ืจื™ืช ื‘ื”ืฉื•ื•ืื” ืœื”ื˜ื‘ื•ืช ื”ืžืชืงื‘ืœื•ืช. ื™ืชืจ ืขืœ ื›ืŸ, ืขื™ื›ื•ื‘ื™ื ื‘ืจืฉืช ื”ื’ื™ืขื• ืœืขืจื›ื™ื ื›ืืœื” ืฉื”ื ืœืžืขืฉื” ืื™ื ื ืžืฉืคื™ืขื™ื ืขืœ ื”ืชื•ืฆืื” ื”ื›ื•ืœืœืช.

ื‘ืงืจ ืฉื™ืจื•ืช ืžื™ื•ื—ื“ VM Cisco HyperFlex Data Platform, ืฉื ื•ืฆืจ ื‘ื›ืœ ืฆื•ืžืช ืื—ืกื•ืŸ, ืื—ืจืื™ ืขืœ ื›ืœ ืœื•ื’ื™ืงื” ื”ืคืขื•ืœื” ืฉืœ ืชืช-ืžืขืจื›ืช ื”ื“ื™ืกืง. ื‘ืชืฆื•ืจืช ื”ืฉื™ืจื•ืช VM ืฉืœื ื•, ื”ื•ืงืฆื• ืฉืžื•ื ื” ืžืขื‘ื“ื™ vCPU ื•-72 GB ืฉืœ ื–ื™ื›ืจื•ืŸ RAM, ื•ื–ื” ืœื ื›ืœ ื›ืš ืžืขื˜. ื”ืจืฉื• ืœื™ ืœื”ื–ื›ื™ืจ ืœื›ื ืฉืœืžืืจื— ืขืฆืžื• ื™ืฉ 28 ืœื™ื‘ื•ืช ืคื™ื–ื™ื•ืช ื•-512 GB ืฉืœ ื–ื™ื›ืจื•ืŸ RAM.

ืœ-VM ืฉืœ ื”ืฉื™ืจื•ืช ื™ืฉ ื’ื™ืฉื” ืœื“ื™ืกืงื™ื ืคื™ื–ื™ื™ื ื™ืฉื™ืจื•ืช ืขืœ ื™ื“ื™ ื”ืขื‘ืจืช ื‘ืงืจ SAS ืœ-VM. ื”ืชืงืฉื•ืจืช ืขื ื”-Hypervisor ืžืชืจื—ืฉืช ื‘ืืžืฆืขื•ืช ืžื•ื“ื•ืœ ืžื™ื•ื—ื“ IOVisor, ื”ืžื™ื™ืจื˜ ืคืขื•ืœื•ืช I/O, ื•ืฉื™ืžื•ืฉ ื‘ืกื•ื›ืŸ ื”ืžืืคืฉืจ ืœืฉืœื•ื— ืคืงื•ื“ื•ืช ืœ-Hypervisor API. ื”ืกื•ื›ืŸ ืื—ืจืื™ ืœืขื‘ื•ื“ื” ืขื ืฆื™ืœื•ืžื™ ืžืฆื‘ ื•ืฉื™ื‘ื•ื˜ื™ื ืฉืœ HyperFlex.

ืžืฉืื‘ื™ ื”ื“ื™ืกืง ืžื•ืชืงื ื™ื ื‘-Hypervisor ื›ืฉื™ืชื•ืคื™ NFS ืื• SMB (ื‘ื”ืชืื ืœืกื•ื’ ื”-Hypervisor, ื ื—ืฉื• ืื™ื–ื” ืžื”ื ื ืžืฆื ื”ื™ื›ืŸ). ื•ืžืชื—ืช ืœืžื›ืกื” ื”ืžื ื•ืข, ืžื“ื•ื‘ืจ ื‘ืžืขืจื›ืช ืงื‘ืฆื™ื ืžื‘ื•ื–ืจืช ื”ืžืืคืฉืจืช ืœื”ื•ืกื™ืฃ ืชื›ื•ื ื•ืช ืฉืœ ืžืขืจื›ื•ืช ืื—ืกื•ืŸ ืžืœืื•ืช ืœืžื‘ื•ื’ืจื™ื: ื”ืงืฆืืช ื ืคื— ื“ืง, ื“ื—ื™ืกื” ื•ืžื ื™ืขืช ื›ืคื™ืœื•ื™ื•ืช, ืฆื™ืœื•ืžื™ ืžืฆื‘ ื‘ื˜ื›ื ื•ืœื•ื’ื™ื™ืช Redirect-on-Write, ืฉื›ืคื•ืœ ืกื™ื ื›ืจื•ื ื™/ืืกื™ื ื›ืจื•ื ื™.

ื”ืฉื™ืจื•ืช VM ืžืกืคืง ื’ื™ืฉื” ืœืžืžืฉืง ื ื™ื”ื•ืœ WEB ืฉืœ ืชืช-ื”ืžืขืจื›ืช HyperFlex. ื™ืฉ ืื™ื ื˜ื’ืจืฆื™ื” ืขื vCenter, ื•ื ื™ืชืŸ ืœื‘ืฆืข ืžืžื ื• ืืช ืจื•ื‘ ื”ืžืฉื™ืžื•ืช ื”ื™ื•ืžื™ื•ืžื™ื•ืช, ืื‘ืœ ืžืื’ืจื™ ื ืชื•ื ื™ื, ืœืžืฉืœ, ื ื•ื—ื™ื ื™ื•ืชืจ ืœื—ืชื•ืš ืžืžืฆืœืžืช ืื™ื ื˜ืจื ื˜ ื ืคืจื“ืช ืื ื›ื‘ืจ ืขื‘ืจืชื ืœืžืžืฉืง HTML5 ืžื”ื™ืจ, ืื• ืžืฉืชืžืฉื™ื ื‘ืœืงื•ื— ืคืœืืฉ ืžืœื. ืขื ืื™ื ื˜ื’ืจืฆื™ื” ืžืœืื”. ื‘ืžืฆืœืžืช ื”ืื™ื ื˜ืจื ื˜ ืฉืœ ื”ืฉื™ืจื•ืช ืชื•ื›ืœื• ืœืฆืคื•ืช ื‘ื‘ื™ืฆื•ืขื™ื ื•ื‘ืกื˜ื˜ื•ืก ื”ืžืคื•ืจื˜ ืฉืœ ื”ืžืขืจื›ืช.

ืื“ืžื™ืŸ ืœืœื ื™ื“ื™ื™ื = ื”ื™ืคืจ ื”ืชื›ื ืกื•ืช?

ืงื™ื™ื ืกื•ื’ ื ื•ืกืฃ ืฉืœ ืฆื•ืžืช ื‘ืืฉื›ื•ืœ - ืฆืžืชื™ ืžื—ืฉื•ื‘. ืืœื” ื™ื›ื•ืœื™ื ืœื”ื™ื•ืช ืฉืจืชื™ ืžืชืœื™ื ืื• ืœื”ื‘ ืœืœื ื“ื™ืกืงื™ื ืžื•ื‘ื ื™ื. ืฉืจืชื™ื ืืœื• ื™ื›ื•ืœื™ื ืœื”ืคืขื™ืœ ืžื—ืฉื‘ื™ VM ืฉื”ื ืชื•ื ื™ื ืฉืœื”ื ืžืื•ื—ืกื ื™ื ื‘ืฉืจืชื™ื ืขื ื“ื™ืกืงื™ื. ืžื ืงื•ื“ืช ืžื‘ื˜ ืฉืœ ื’ื™ืฉื” ืœื ืชื•ื ื™ื, ืื™ืŸ ื”ื‘ื“ืœ ื‘ื™ืŸ ืกื•ื’ื™ ื”ืฆืžืชื™ื, ืžื›ื™ื•ื•ืŸ ืฉื”ืืจื›ื™ื˜ืงื˜ื•ืจื” ื›ืจื•ื›ื” ื‘ื”ืคืฉื˜ื” ืžื”ืžื™ืงื•ื ื”ืคื™ื–ื™ ืฉืœ ื”ื ืชื•ื ื™ื. ื”ื™ื—ืก ื”ืžืจื‘ื™ ื‘ื™ืŸ ืฆืžืชื™ ืžื—ืฉื•ื‘ ืœืฆืžืชื™ ืื—ืกื•ืŸ ื”ื•ื 2:1.

ืฉื™ืžื•ืฉ ื‘ืฆืžืชื™ ืžื—ืฉื•ื‘ ืžื’ื‘ื™ืจ ืืช ื”ื’ืžื™ืฉื•ืช ื‘ืขืช ืฉื™ื ื•ื™ ืงื ื” ื”ืžื™ื“ื” ืฉืœ ืžืฉืื‘ื™ ืืฉื›ื•ืœื•ืช: ืื ื—ื ื• ืœื ืฆืจื™ื›ื™ื ืœืงื ื•ืช ืฆืžืชื™ื ื ื•ืกืคื™ื ืขื ื“ื™ืกืงื™ื ืื ืื ื—ื ื• ืฆืจื™ื›ื™ื ืจืง CPU/RAM. ื‘ื ื•ืกืฃ, ื ื•ื›ืœ ืœื”ื•ืกื™ืฃ ื›ืœื•ื‘ ืœื”ื‘ ื•ืœื—ืกื•ืš ื‘ืžื™ืงื•ื ืžืชืœื” ืฉืœ ืฉืจืชื™ื.

ื›ืชื•ืฆืื” ืžื›ืš, ื™ืฉ ืœื ื• ืคืœื˜ืคื•ืจืžืช ื”ื™ืคืจ-ืงื•ื ื‘ืจื–ืฆื™ื” ืขื ื”ืชื›ื•ื ื•ืช ื”ื‘ืื•ืช:

  • ืขื“ 64 ืฆืžืชื™ื ื‘ืืฉื›ื•ืœ (ืขื“ 32 ืฆืžืชื™ื ืื—ืกื•ืŸ).
  • ื”ืžืกืคืจ ื”ืžื™ื ื™ืžืœื™ ืฉืœ ืฆืžืชื™ื ื‘ืืฉื›ื•ืœ ื”ื•ื ืฉืœื•ืฉื” (ืฉื ื™ื™ื ืขื‘ื•ืจ ืืฉื›ื•ืœ Edge).
  • ืžื ื’ื ื•ืŸ ื™ืชื™ืจื•ืช ื ืชื•ื ื™ื: ืฉื™ืงื•ืฃ ืขื ืคืงื˜ื•ืจ ืฉื›ืคื•ืœ 2 ื•-3.
  • ืืฉื›ื•ืœ ืžื˜ืจื•.
  • ืฉื›ืคื•ืœ VM ืืกื™ื ื›ืจื•ื ื™ ืœืืฉื›ื•ืœ HyperFlex ืื—ืจ.
  • ืชื–ืžื•ืจ ืฉืœ ื”ืขื‘ืจืช ืžื—ืฉื‘ื™ VM ืœืžืจื›ื– ื ืชื•ื ื™ื ืžืจื•ื—ืง.
  • ืฆื™ืœื•ืžื™ ืžืฆื‘ ืžืงื•ืจื™ื™ื ื‘ืืžืฆืขื•ืช ื˜ื›ื ื•ืœื•ื’ื™ื™ืช Redirect-on-Write.
  • ืขื“ 1 PB ืฉืœ ืฉื˜ื— ืฉืžื™ืฉ ื‘ืžืงื“ื ืฉื›ืคื•ืœ 3 ื•ืœืœื ืžื ื™ืขืช ื›ืคื™ืœื•ื™ื•ืช. ืื ื—ื ื• ืœื ืœื•ืงื—ื™ื ื‘ื—ืฉื‘ื•ืŸ ืืช ืคืงื˜ื•ืจ ืฉื›ืคื•ืœ 2, ื›ื™ ื–ื• ืœื ืื•ืคืฆื™ื” ืœืžื›ื™ืจื•ืช ืจืฆื™ื ื™ื•ืช.

ื™ืชืจื•ืŸ ืขื ืง ื ื•ืกืฃ ื”ื•ื ืงืœื•ืช ื”ื ื™ื”ื•ืœ ื•ื”ืคืจื™ืกื”. ื›ืœ ื”ืžื•ืจื›ื‘ื•ืช ืฉืœ ื”ืงืžืช ืฉืจืชื™ UCS ืžื˜ื•ืคืœืช ืขืœ ื™ื“ื™ VM ืžื™ื•ื—ื“ ืฉื”ื•ื›ืŸ ืขืœ ื™ื“ื™ ืžื”ื ื“ืกื™ ืกื™ืกืงื•.

ืชืฆื•ืจืช ืกืคืกืœ ื‘ื“ื™ืงื”:

  • 2 x Cisco UCS Fabric Interconnect 6248UP ื›ืืฉื›ื•ืœ ื ื™ื”ื•ืœ ื•ืจื›ื™ื‘ื™ ืจืฉืช (48 ื™ืฆื™ืื•ืช ื”ืคื•ืขืœื•ืช ื‘ืžืฆื‘ Ethernet 10G/FC 16G).
  • ืืจื‘ืขื” ืฉืจืชื™ Cisco UCS HXAF240 M4.

ืžืืคื™ื™ื ื™ ืฉืจืช:

CPU

2 x Intelยฎ Xeonยฎ E5-2690 v4

RAM

16 x 32GB DDR4-2400-MHz RDIMM/PC4-19200/ื“ืจื•ื’ ื›ืคื•ืœ/x4/1.2v

ืจืฉืช

UCSC-MLOM-CSC-02 (VIC 1227). 2 ื™ืฆื™ืื•ืช Ethernet 10G

ืื—ืกื•ืŸ HBA

Cisco 12G Modular SAS Pass through Controller

ื“ื™ืกืงื™ ืื—ืกื•ืŸ

1 x SSD Intel S3520 120 GB, 1 x SSD Samsung MZ-IES800D, 10 x SSD Samsung PM863a 960 GB

ืืคืฉืจื•ื™ื•ืช ืชืฆื•ืจื” ื ื•ืกืคื•ืชื‘ื ื•ืกืฃ ืœื—ื•ืžืจื” ืฉื ื‘ื—ืจื”, ื”ืืคืฉืจื•ื™ื•ืช ื”ื‘ืื•ืช ื–ืžื™ื ื•ืช ื›ืขืช:

  • HXAF240c M5.
  • ืžืขื‘ื“ ืื—ื“ ืื• ืฉื ื™ื™ื ื”ื—ืœ ืž-Intel Silver 4110 ื•ืขื“ Intel Platinum I8260Y. ื“ื•ืจ ืฉื ื™ ื–ืžื™ืŸ.
  • 24 ื—ืจื™ืฆื™ ื–ื™ื›ืจื•ืŸ, ืจืฆื•ืขื•ืช ืž-16 GB RDIMM 2600 ืขื“ 128 GB LRDIMM 2933.
  • ืž-6 ืขื“ 23 ื“ื™ืกืงื™ ื ืชื•ื ื™ื, ื“ื™ืกืง ืžื˜ืžื•ืŸ ืื—ื“, ื“ื™ืกืง ืžืขืจื›ืช ืื—ื“ ื•ื“ื™ืกืง ืืชื—ื•ืœ ืื—ื“.

ื›ื•ื ื ื™ ืงื™ื‘ื•ืœืช

  • HX-SD960G61X-EV 960GB 2.5 ืื™ื ืฅ' Enterprise Value 6G SATA SSD (1X ืกื™ื‘ื•ืœืช) SAS 960 GB.
  • HX-SD38T61X-EV 3.8TB 2.5 ืื™ื ืฅ' Enterprise Value 6G SATA SSD (1X ืกื™ื‘ื•ืœืช) SAS 3.8TB.
  • ืื—ืกื•ืŸ ื›ื•ื ื ื™ื ื‘ืžื˜ืžื•ืŸ
  • HX-NVMEXPB-I375 375GB 2.5 ืื™ื ืฅ' Intel Optane Drive, Extreme Perf & Endurance.
  • HX-NVMEHW-H1600* 1.6TB 2.5 ืื™ื ืฅ' Ent. Perf. NVMe SSD (3X ืกื™ื‘ื•ืœืช) NVMe 1.6 TB.
  • HX-SD400G12TX-EP 400GB 2.5 ืื™ื ืฅ' Ent. Perf. 12G SAS SSD (10X ืกื™ื‘ื•ืœืช) SAS 400 GB.
  • HX-SD800GBENK9** 800GB 2.5 ืื™ื ืฅ' Ent. Perf. 12G SAS SED SSD (10X ืกื™ื‘ื•ืœืช) SAS 800 GB.
  • HX-SD16T123X-EP 1.6TB 2.5 ืื™ื ืฅ' ื‘ื™ืฆื•ืขื™ื ืืจื’ื•ื ื™ื™ื 12G SAS SSD (3X ืกื™ื‘ื•ืœืช).

ื›ื•ื ื ื™ ืžืขืจื›ืช/ื™ื•ืžืŸ

  • HX-SD240GM1X-EV 240GB 2.5 ืื™ื ืฅ' Enterprise Value 6G SATA SSD (ื“ื•ืจืฉ ืฉื“ืจื•ื’).

ืืชื—ื•ืœ ื›ื•ื ื ื™

  • HX-M2-240GB 240GB SATA M.2 SSD SATA 240GB.

ื”ืชื—ื‘ืจ ืœืจืฉืช ื‘ืืžืฆืขื•ืช ื™ืฆื™ืื•ืช 40G, 25G ืื• 10G Ethernet.

ื”-FI ื™ื›ื•ืœ ืœื”ื™ื•ืช HX-FI-6332 (40G), HX-FI-6332-16UP (40G), HX-FI-6454 (40G/100G).

ื”ื‘ื“ื™ืงื” ืขืฆืžื”

ื›ื“ื™ ืœื‘ื“ื•ืง ืืช ืชืช-ืžืขืจื›ืช ื”ื“ื™ืกืง, ื”ืฉืชืžืฉืชื™ ื‘-HCIBench 2.2.1. ื–ื”ื• ื›ืœื™ ื—ื™ื ืžื™ ื”ืžืืคืฉืจ ืœืš ืœื”ืคื•ืš ืืช ื”ื™ืฆื™ืจื” ืฉืœ ืขื•ืžืก ืžืžืกืคืจ ืžื›ื•ื ื•ืช ื•ื™ืจื˜ื•ืืœื™ื•ืช ืœืื•ื˜ื•ืžื˜ื™ื•ืช. ื”ืขื•ืžืก ืขืฆืžื• ื ื•ืฆืจ ืขืœ ื™ื“ื™ ื”-fio ื”ืจื’ื™ืœ.

ื”ืืฉื›ื•ืœ ืฉืœื ื• ืžื•ืจื›ื‘ ืžืืจื‘ืขื” ืฆืžืชื™ื, ื’ื•ืจื ืฉื›ืคื•ืœ 3, ื›ืœ ื”ื“ื™ืกืงื™ื ื”ื ืคืœืืฉ.

ืœืฆื•ืจืš ื‘ื“ื™ืงื”, ื™ืฆืจืชื™ ืืจื‘ืข ื—ื ื•ื™ื•ืช ื ืชื•ื ื™ื ื•ืฉืžื•ื ื” ืžื›ื•ื ื•ืช ื•ื™ืจื˜ื•ืืœื™ื•ืช. ืขื‘ื•ืจ ืžื‘ื—ื ื™ ื›ืชื™ื‘ื”, ื”ื”ื ื—ื” ื”ื™ื ืฉื“ื™ืกืง ื”ืžื˜ืžื•ืŸ ืื™ื ื• ืžืœื.

ืชื•ืฆืื•ืช ื”ื‘ื“ื™ืงื” ื”ืŸ ื›ื“ืœืงืžืŸ:

100% ืงืจื™ืื” 100% ืืงืจืื™ืช

0% ืงืจื™ืื” 100% ืืงืจืื™ืช

ืขื•ืžืง ื—ืกื™ืžื”/ืชื•ืจ

128

256

512

1024

2048

128

256

512

1024

2048

4K

0,59 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 213804 IOPS

0,84 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 303540 IOPS

1,36ms 374348 IOPS

2.47 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 414116 IOPS

4,86ms 420180 IOPS

2,22 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 57408 IOPS

3,09 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 82744 IOPS

5,02 ms 101824 IPOS

8,75 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 116912 IOPS

17,2 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 118592 IOPS

8K

0,67 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 188416 IOPS

0,93 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 273280 IOPS

1,7 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 299932 IOPS

2,72 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 376,484 IOPS

5,47 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 373,176 IOPS

3,1 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 41148 IOPS

4,7 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 54396 IOPS

7,09 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 72192 IOPS

12,77 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 80132 IOPS

16K

0,77 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 164116 IOPS

1,12 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 228328 IOPS

1,9 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 268140 IOPS

3,96 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 258480 IOPS

3,8 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 33640 IOPS

6,97 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 36696 IOPS

11,35 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 45060 IOPS

32K

1,07 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 119292 IOPS

1,79 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 142888 IOPS

3,56 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 143760 IOPS

7,17 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 17810 IOPS

11,96 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 21396 IOPS

64K

1,84 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 69440 IOPS

3,6 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 71008 IOPS

7,26 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 70404 IOPS

11,37 ืืœืคื™ื•ืช ื”ืฉื ื™ื™ื” 11248 IOPS

ืžื•ื“ื’ืฉ ืžืฆื™ื™ืŸ ืขืจื›ื™ื ืฉืœืื—ืจื™ื”ื ืื™ืŸ ืขืœื™ื™ื” ื‘ืชืคื•ืงื”, ืœืคืขืžื™ื ืืคื™ืœื• ื ืจืื” ื”ืฉืคืœื”. ื–ืืช ื‘ืฉืœ ื”ืขื•ื‘ื“ื” ืฉืื ื• ืžื•ื’ื‘ืœื™ื ืขืœ ื™ื“ื™ ื‘ื™ืฆื•ืขื™ ื”ืจืฉืช/ื‘ืงืจื™ื/ื“ื™ืกืงื™ื.

  • ืงืจื™ืื” ืจืฆื™ืคื” 4432 MB/s.
  • ื›ืชื™ื‘ื” ืจืฆื™ืคื” 804 ืžื’ื”-ื‘ื™ื™ื˜/ืฉื ื™ื™ื”.
  • ืื ื‘ืงืจ ืื—ื“ ื ื›ืฉืœ (ื›ืฉืœ ืฉืœ ืžื›ื•ื ื” ื•ื™ืจื˜ื•ืืœื™ืช ืื• ืžืืจื—), ื”ื™ืจื™ื“ื” ื‘ื‘ื™ืฆื•ืขื™ื ื”ื™ื ื›ืคื•ืœื”.
  • ืื ื“ื™ืกืง ื”ืื—ืกื•ืŸ ื ื›ืฉืœ, ื”ื”ืคื—ืชื” ื”ื™ื 1/3. ื‘ื ื™ื™ื” ืžื—ื“ืฉ ืฉืœ ื“ื™ืกืง ืœื•ืงื—ืช 5% ืžื”ืžืฉืื‘ื™ื ืฉืœ ื›ืœ ื‘ืงืจ.

ื‘ื‘ืœื•ืง ืงื˜ืŸ, ืื ื• ืžื•ื’ื‘ืœื™ื ืขืœ ื™ื“ื™ ื”ื‘ื™ืฆื•ืขื™ื ืฉืœ ื”ื‘ืงืจ (ืžื›ื•ื ื” ื•ื™ืจื˜ื•ืืœื™ืช), ื”ืžืขื‘ื“ ืฉืœื• ื ื˜ืขืŸ ื‘-100%, ื•ื›ืืฉืจ ื”ื‘ืœื•ืง ื’ื“ืœ, ืื ื• ืžื•ื’ื‘ืœื™ื ืขืœ ื™ื“ื™ ืจื•ื—ื‘ ื”ืคืก ืฉืœ ื”ืคื•ืจื˜. 10 Gbps ืœื ืžืกืคื™ืง ื›ื“ื™ ืœืคืชื•ื— ืืช ื”ืคื•ื˜ื ืฆื™ืืœ ืฉืœ ืžืขืจื›ืช AllFlash. ืœืžืจื‘ื” ื”ืฆืขืจ, ื”ืคืจืžื˜ืจื™ื ืฉืœ ืขืžื“ืช ื”ื”ื“ื’ืžื” ื”ืžืกื•ืคืงืช ืื™ื ื ืžืืคืฉืจื™ื ืœื ื• ืœื‘ื“ื•ืง ืืช ื”ืคืขื•ืœื” ื‘ืžื”ื™ืจื•ืช 40 Gbit/s.

ืœืคื™ ื”ืชืจืฉืžื•ืชื™ ืžื‘ื“ื™ืงื•ืช ื•ืœื™ืžื•ื“ ื”ืืจื›ื™ื˜ืงื˜ื•ืจื”, ื‘ื’ืœืœ ื”ืืœื’ื•ืจื™ืชื ืฉืžืฆื™ื‘ ื ืชื•ื ื™ื ื‘ื™ืŸ ื›ืœ ื”ืžืืจื—ื™ื, ืื ื—ื ื• ืžืงื‘ืœื™ื ื‘ื™ืฆื•ืขื™ื ื ื™ืชื ื™ื ืœื”ืจื—ื‘ื” ื•ื ื™ืชื ื™ื ืœื—ื™ื–ื•ื™, ืื‘ืœ ื–ื• ื’ื ืžื’ื‘ืœื” ื‘ืงืจื™ืื”, ื›ื™ ืืคืฉืจ ื™ื”ื™ื” ืœืกื—ื•ื˜ ื™ื•ืชืจ ืžื“ื™ืกืงื™ื ืžืงื•ืžื™ื™ื, ื›ืืŸ ื–ื” ืขืฉื•ื™ ืœื”ืฆื™ืœ ืจืฉืช ืคืจื•ื“ื•ืงื˜ื™ื‘ื™ืช ื™ื•ืชืจ, ืœื“ื•ื’ืžื”, FI ื‘ืžื”ื™ืจื•ืช 40 Gbit/s ื–ืžื™ืŸ.

ื›ืžื• ื›ืŸ, ื“ื™ืกืง ืื—ื“ ืœืื—ืกื•ืŸ ื‘ืžื˜ืžื•ืŸ ื•ืœืžื ื™ืขืช ื›ืคื™ืœื•ื™ื•ืช ืขืฉื•ื™ ืœื”ื™ื•ืช ืžื’ื‘ืœื”; ืœืžืขืฉื”, ื‘ืžื‘ื—ืŸ ื–ื” ืื ื• ื™ื›ื•ืœื™ื ืœื›ืชื•ื‘ ืœืืจื‘ืขื” ื“ื™ืกืงื™ SSD. ื–ื” ื™ื”ื™ื” ื ื”ื“ืจ ืœื”ื™ื•ืช ืžืกื•ื’ืœ ืœื”ื’ื“ื™ืœ ืืช ืžืกืคืจ ื›ื•ื ื ื™ ื”ืžื˜ืžื•ืŸ ื•ืœืจืื•ืช ืืช ื”ื”ื‘ื“ืœ.

ืฉื™ืžื•ืฉ ืืžื™ืชื™

ื›ื“ื™ ืœืืจื’ืŸ ืžืจื›ื– ื ืชื•ื ื™ื ืœื’ื™ื‘ื•ื™, ืืชื” ื™ื›ื•ืœ ืœื”ืฉืชืžืฉ ื‘ืฉืชื™ ื’ื™ืฉื•ืช (ืื™ื ื ื• ืฉื•ืงืœื™ื ืœืžืงื ื’ื™ื‘ื•ื™ ื‘ืืชืจ ืžืจื•ื—ืง):

  1. ืคืขื™ืœ ืกื‘ื™ืœ. ื›ืœ ื”ืืคืœื™ืงืฆื™ื•ืช ืžืชืืจื—ื•ืช ื‘ืžืจื›ื– ื”ื ืชื•ื ื™ื ื”ืจืืฉื™. ื”ืฉื›ืคื•ืœ ื”ื•ื ืกื™ื ื›ืจื•ื ื™ ืื• ืืกื™ื ื›ืจื•ื ื™. ืื ืžืจื›ื– ื”ื ืชื•ื ื™ื ื”ืจืืฉื™ ื ื›ืฉืœ, ืขืœื™ื ื• ืœื”ืคืขื™ืœ ืืช ื”ื’ื™ื‘ื•ื™. ื ื™ืชืŸ ืœืขืฉื•ืช ื–ืืช ื‘ืื•ืคืŸ ื™ื“ื ื™ / ื™ื™ืฉื•ืžื™ ืกืงืจื™ืคื˜ื™ื / ืชื–ืžื•ืจ. ื›ืืŸ ื ืงื‘ืœ RPO ื”ืชื•ืื ืืช ืชื“ื™ืจื•ืช ื”ืฉื›ืคื•ืœ, ื•ื”-RTO ืชืœื•ื™ ื‘ืชื’ื•ื‘ื” ื•ื‘ื›ื™ืฉื•ืจื™ ื”ืžื ื”ืœ ื•ื‘ืื™ื›ื•ืช ื”ืคื™ืชื•ื—/ื ื™ืคื•ื™ ื‘ืื’ื™ื ืฉืœ ืชื•ื›ื ื™ืช ื”ืžื™ืชื•ื’.
  2. ืคืขื™ืœ- ืคืขื™ืœ. ื‘ืžืงืจื” ื–ื”, ื™ืฉ ืจืง ืฉื›ืคื•ืœ ืกื™ื ื›ืจื•ื ื™; ื–ืžื™ื ื•ืช ืžืจื›ื–ื™ ื”ื ืชื•ื ื™ื ื ืงื‘ืขืช ืขืœ ื™ื“ื™ ืžื ื™ื™ืŸ/ื‘ื•ืจืจ ืฉื ืžืฆื ืืš ื•ืจืง ื‘ืืชืจ ื”ืฉืœื™ืฉื™. RPO = 0, ื•-RTO ื™ื›ื•ืœ ืœื”ื’ื™ืข ืœ-0 (ืื ื”ืืคืœื™ืงืฆื™ื” ืžืืคืฉืจืช) ืื• ืฉื•ื•ื” ืœื–ืžืŸ ื”ื›ืฉืœ ืฉืœ ืฆื•ืžืช ื‘ืืฉื›ื•ืœ ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื”. ื‘ืจืžืช ื”ื•ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื”, ื ื•ืฆืจ ืืฉื›ื•ืœ ืžืชื•ื— (ืžื˜ืจื•) ื”ื“ื•ืจืฉ ืื—ืกื•ืŸ ืืงื˜ื™ื‘ื™.

ื‘ื“ืจืš ื›ืœืœ ืื ื• ืจื•ืื™ื ืฉืœืงื•ื—ื•ืช ื›ื‘ืจ ื”ื˜ืžื™ืขื• ืืจื›ื™ื˜ืงื˜ื•ืจื” ืขื ืžืขืจื›ืช ืื—ืกื•ืŸ ืงืœืืกื™ืช ื‘ืžืจื›ื– ื”ื ืชื•ื ื™ื ื”ืจืืฉื™, ืื– ืื ื• ืžืชื›ื ื ื™ื ืขื•ื“ ืื—ืช ืœืฉื›ืคื•ืœ. ื›ืคื™ ืฉืฆื™ื™ื ืชื™, Cisco HyperFlex ืžืฆื™ืขื” ืฉื›ืคื•ืœ ืืกื™ื ื›ืจื•ื ื™ ื•ื™ืฆื™ืจืช ืืฉื›ื•ืœื•ืช ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื” ืžืชื•ื—ื™ื. ื™ื—ื“ ืขื ื–ืืช, ืื™ื ื ื• ื–ืงื•ืงื™ื ืœืžืขืจื›ืช ืื—ืกื•ืŸ ื™ื™ืขื•ื“ื™ืช ื‘ืจืžืช Midrange ื•ืžืขืœื” ืขื ืคื•ื ืงืฆื™ื•ืช ืฉื›ืคื•ืœ ื™ืงืจื•ืช ื•ื’ื™ืฉื” Active-Active ืœื ืชื•ื ื™ื ื‘ืฉืชื™ ืžืขืจื›ื•ืช ืื—ืกื•ืŸ.

ืชืจื—ื™ืฉ 1: ื™ืฉ ืœื ื• ืžืจื›ื–ื™ ื ืชื•ื ื™ื ืจืืฉื™ื™ื ื•ื’ื™ื‘ื•ื™, ืคืœื˜ืคื•ืจืžืช ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื” ื‘-VMware vSphere. ื›ืœ ื”ืžืขืจื›ื•ืช ื”ืคืจื•ื“ื•ืงื˜ื™ื‘ื™ื•ืช ืžืžื•ืงืžื•ืช ื‘ืžืจื›ื– ื”ื ืชื•ื ื™ื ื”ืจืืฉื™, ื•ืฉื›ืคื•ืœ ืฉืœ ืžื›ื•ื ื•ืช ื•ื™ืจื˜ื•ืืœื™ื•ืช ืžืชื‘ืฆืข ื‘ืจืžืช ื”-Hypervisor, ื–ื” ื™ืžื ืข ื”ืฉืืจืช ืžื—ืฉื‘ื™ VM ืžื•ืคืขืœื™ื ื‘ืžืจื›ื– ื”ื ืชื•ื ื™ื ื”ื’ื™ื‘ื•ื™. ืื ื• ืžืฉื›ืคืœื™ื ืžืกื“ื™ ื ืชื•ื ื™ื ื•ื™ื™ืฉื•ืžื™ื ืžื™ื•ื—ื“ื™ื ื‘ืืžืฆืขื•ืช ื›ืœื™ื ืžื•ื‘ื ื™ื ื•ืฉื•ืžืจื™ื ืขืœ ื”-VMs ืžื•ืคืขืœื™ื. ืื ืžืจื›ื– ื”ื ืชื•ื ื™ื ื”ืจืืฉื™ ื ื›ืฉืœ, ืื ื• ืžืฉื™ืงื™ื ืžืขืจื›ื•ืช ื‘ืžืจื›ื– ื”ื ืชื•ื ื™ื ืœื’ื™ื‘ื•ื™. ืื ื• ืžืืžื™ื ื™ื ืฉื™ืฉ ืœื ื• ื›-100 ืžื›ื•ื ื•ืช ื•ื™ืจื˜ื•ืืœื™ื•ืช. ื‘ืขื•ื“ ืฉืžืจื›ื– ื”ื ืชื•ื ื™ื ื”ืจืืฉื™ ืคื•ืขืœ, ืžืจื›ื– ื”ื ืชื•ื ื™ื ื‘ื”ืžืชื ื” ื™ื›ื•ืœ ืœื”ืจื™ืฅ ืกื‘ื™ื‘ื•ืช ื‘ื“ื™ืงื” ื•ืžืขืจื›ื•ืช ืื—ืจื•ืช ืฉื ื™ืชืŸ ืœื›ื‘ื•ืช ืื•ืชืŸ ืื ืžืจื›ื– ื”ื ืชื•ื ื™ื ื”ืจืืฉื™ ื™ืขื‘ื•ืจ. ื™ื™ืชื›ืŸ ื’ื ืฉืื ื• ืžืฉืชืžืฉื™ื ื‘ืฉื›ืคื•ืœ ื“ื•-ื›ื™ื•ื•ื ื™. ืžื ืงื•ื“ืช ืžื‘ื˜ ืฉืœ ื—ื•ืžืจื”, ืฉื•ื ื“ื‘ืจ ืœื ื™ืฉืชื ื”.

ื‘ืžืงืจื” ืฉืœ ืืจื›ื™ื˜ืงื˜ื•ืจื” ืงืœืืกื™ืช, ื ืชืงื™ืŸ ื‘ื›ืœ ืžืจื›ื– ื ืชื•ื ื™ื ืžืขืจื›ืช ืื—ืกื•ืŸ ื”ื™ื‘ืจื™ื“ื™ืช ืขื ื’ื™ืฉื” ื“ืจืš FibreChannel, ืฉื›ื‘ื•ืช, ืžื ื™ืขืช ื›ืคื™ืœื•ื™ื•ืช ื•ื“ื—ื™ืกื” (ืืš ืœื ืžืงื•ื•ื ืช), 8 ืฉืจืชื™ื ืœื›ืœ ืืชืจ, 2 ืžืชื’ื™ FibreChannel ื•-10G Ethernet. ืœืฉื›ืคื•ืœ ื•ื ื™ื”ื•ืœ ืžื™ืชื•ื’ ื‘ืืจื›ื™ื˜ืงื˜ื•ืจื” ืงืœืืกื™ืช ื ื•ื›ืœ ืœื”ืฉืชืžืฉ ื‘ื›ืœื™ VMware (Replication + SRM) ืื• ื‘ื›ืœื™ื ืฉืœ ืฆื“ ืฉืœื™ืฉื™, ืฉื™ื”ื™ื• ืงืฆืช ื™ื•ืชืจ ื–ื•ืœื™ื ื•ืœืขื™ืชื™ื ื ื•ื—ื™ื ื™ื•ืชืจ.

ื”ืื™ื•ืจ ืžืฆื™ื’ ืืช ื”ืชืจืฉื™ื.

ืื“ืžื™ืŸ ืœืœื ื™ื“ื™ื™ื = ื”ื™ืคืจ ื”ืชื›ื ืกื•ืช?

ื‘ืขืช ืฉื™ืžื•ืฉ ื‘-Cisco HyperFlex, ืžืชืงื‘ืœืช ื”ืืจื›ื™ื˜ืงื˜ื•ืจื” ื”ื‘ืื”:

ืื“ืžื™ืŸ ืœืœื ื™ื“ื™ื™ื = ื”ื™ืคืจ ื”ืชื›ื ืกื•ืช?

ืขื‘ื•ืจ HyperFlex, ื”ืฉืชืžืฉืชื™ ื‘ืฉืจืชื™ื ืขื ืžืฉืื‘ื™ CPU/RAM ื’ื“ื•ืœื™ื, ื›ื™... ื—ืœืง ืžื”ืžืฉืื‘ื™ื ื™ืขื‘ืจื• ืœ-HyperFlex Controller VM; ืžื‘ื—ื™ื ืช CPU ื•ื–ื™ื›ืจื•ืŸ, ืืคื™ืœื• ื”ื’ื“ืจืชื™ ืžื—ื“ืฉ ืžืขื˜ ืืช ืชืฆื•ืจืช HyperFlex ื›ื“ื™ ืœื ืœืฉื—ืง ื™ื—ื“ ืขื Cisco ื•ืœื”ื‘ื˜ื™ื— ืžืฉืื‘ื™ื ืขื‘ื•ืจ ื”-VMs ืฉื ื•ืชืจื•. ืื‘ืœ ืื ื—ื ื• ื™ื›ื•ืœื™ื ืœื ื˜ื•ืฉ ืืช ืžืชื’ื™ FibreChannel, ื•ืœื ื ืฆื˜ืจืš ื™ืฆื™ืื•ืช Ethernet ืขื‘ื•ืจ ื›ืœ ืฉืจืช; ื”ืชืขื‘ื•ืจื” ื”ืžืงื•ืžื™ืช ืขื•ื‘ืจืช ื‘ืชื•ืš FI.

ื”ืชื•ืฆืื” ื”ื™ื™ืชื” ื”ืชืฆื•ืจื” ื”ื‘ืื” ืขื‘ื•ืจ ื›ืœ ืžืจื›ื– ื ืชื•ื ื™ื:

ืฉืจืชื™ื

ืฉืจืช 8 x 1U (384 GB RAM, 2 x Intel Gold 6132, FC HBA)

8 x HX240C-M5L (512 GB RAM, 2 x Intel Gold 6150, 3,2 GB SSD, 10 x 6 TB NL-SAS)

SHD

ืžืขืจื›ืช ืื—ืกื•ืŸ ื”ื™ื‘ืจื™ื“ื™ืช ืขื FC Front-End (20TB SSD, 130TB NL-SAS)

-

LAN

2 x ืžืชื’ Ethernet 10G 12 ื™ืฆื™ืื•ืช

-

SAN

2 x ืžืชื’ FC 32/16Gb 24 ื™ืฆื™ืื•ืช

2 x Cisco UCS FI 6332

ืจื™ืฉื™ื•ื ื•ืช

VMware Ent Plus

ืฉื›ืคื•ืœ ื•/ืื• ืชื–ืžื•ืจ ืฉืœ ืžื™ืชื•ื’ VM

VMware Ent Plus

ืœื ืกื™ืคืงืชื™ ืจื™ืฉื™ื•ื ื•ืช ืชื•ื›ื ืช ืฉื›ืคื•ืœ ืขื‘ื•ืจ Hyperflex, ืžื›ื™ื•ื•ืŸ ืฉื–ื” ื–ืžื™ืŸ ืขื‘ื•ืจื ื• ืžื”ืงื•ืคืกื”.

ืœืืจื›ื™ื˜ืงื˜ื•ืจื” ืงืœืืกื™ืช ื‘ื—ืจืชื™ ื‘ืกืคืง ืฉื‘ื™ืกืก ืืช ืขืฆืžื• ื›ื™ืฆืจืŸ ืื™ื›ื•ืชื™ ื•ื–ื•ืœ. ืขื‘ื•ืจ ืฉืชื™ ื”ืืคืฉืจื•ื™ื•ืช, ื”ื—ืœืชื™ ืืช ื”ื”ื ื—ื” ื”ืกื˜ื ื“ืจื˜ื™ืช ืขื‘ื•ืจ ืคืชืจื•ืŸ ืกืคืฆื™ืคื™, ื•ื›ืชื•ืฆืื” ืžื›ืš ืงื™ื‘ืœืชื™ ืžื—ื™ืจื™ื ืืžื™ืชื™ื™ื.

ื”ืคืชืจื•ืŸ ืฉืœ Cisco HyperFlex ื”ืชื‘ืจืจ ื›-13% ื™ื•ืชืจ ื–ื•ืœ.

ืชืจื—ื™ืฉ 2: ื™ืฆื™ืจืช ืฉื ื™ ืžืจื›ื–ื™ ื ืชื•ื ื™ื ืคืขื™ืœื™ื. ื‘ืชืจื—ื™ืฉ ื–ื”, ืื ื• ืžืชื›ื ื ื™ื ืืฉื›ื•ืœ ืžืชื•ื— ื‘-VMware.

ื”ืืจื›ื™ื˜ืงื˜ื•ืจื” ื”ืงืœืืกื™ืช ืžื•ืจื›ื‘ืช ืžืฉืจืชื™ ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื”, SAN (ืคืจื•ื˜ื•ืงื•ืœ FC) ื•ืฉืชื™ ืžืขืจื›ื•ืช ืื—ืกื•ืŸ ืฉื™ื›ื•ืœื•ืช ืœืงืจื•ื ื•ืœื›ืชื•ื‘ ืœื ืคื— ื”ืžืชื•ื— ื‘ื™ื ื™ื”ื. ืขืœ ื›ืœ ืžืขืจื›ืช ืื—ืกื•ืŸ ืฉืžื ื• ืงื™ื‘ื•ืœืช ืฉื™ืžื•ืฉื™ืช ืœืื—ืกื•ืŸ.

ืื“ืžื™ืŸ ืœืœื ื™ื“ื™ื™ื = ื”ื™ืคืจ ื”ืชื›ื ืกื•ืช?

ื‘-HyperFlex ืื ื—ื ื• ืคืฉื•ื˜ ื™ื•ืฆืจื™ื Stretch Cluster ืขื ืื•ืชื• ืžืกืคืจ ืฆืžืชื™ื ื‘ืฉื ื™ ื”ืืชืจื™ื. ื‘ืžืงืจื” ื–ื”, ื ืขืฉื” ืฉื™ืžื•ืฉ ื‘ืžืงื“ื ืฉื›ืคื•ืœ ืฉืœ 2+2.

ืื“ืžื™ืŸ ืœืœื ื™ื“ื™ื™ื = ื”ื™ืคืจ ื”ืชื›ื ืกื•ืช?

ื”ืชื•ืฆืื” ื”ื™ื ื”ืชืฆื•ืจื” ื”ื‘ืื”:

ืื“ืจื™ื›ืœื•ืช ืงืœืืกื™ืช

HyperFlex

ืฉืจืชื™ื

ืฉืจืช 16 x 1U (384 GB RAM, 2 x Intel Gold 6132, FC HBA, 2 x 10G NIC)

16 x HX240C-M5L (512 GB RAM, 2 x Intel Gold 6132, 1,6 TB NVMe, 12 x 3,8 TB SSD, VIC 1387)

SHD

2 x ืžืขืจื›ื•ืช ืื—ืกื•ืŸ AllFlash (150 TB SSD)

-

LAN

4 x ืžืชื’ Ethernet 10G 24 ื™ืฆื™ืื•ืช

-

SAN

4 x ืžืชื’ FC 32/16Gb 24 ื™ืฆื™ืื•ืช

4 x Cisco UCS FI 6332

ืจื™ืฉื™ื•ื ื•ืช

VMware Ent Plus

VMware Ent Plus

ื‘ื›ืœ ื”ื—ื™ืฉื•ื‘ื™ื ืœื ืœืงื—ืชื™ ื‘ื—ืฉื‘ื•ืŸ ืืช ืชืฉืชื™ืช ื”ืจืฉืช, ืขืœื•ื™ื•ืช ื”ื“ืื˜ื” ืกื ื˜ืจ ื•ื›ื•': ื”ืŸ ื™ื”ื™ื• ื–ื”ื•ืช ืœืืจื›ื™ื˜ืงื˜ื•ืจื” ื”ืงืœืืกื™ืช ื•ืœืคืชืจื•ืŸ HyperFlex.

ืžื‘ื—ื™ื ืช ืขืœื•ืช, HyperFlex ื”ืชื‘ืจืจ ื›ื™ืงืจ ื‘-5%. ื›ื“ืื™ ืœืฆื™ื™ืŸ ื›ืืŸ ืฉืžื‘ื—ื™ื ืช ืžืฉืื‘ื™ CPU/RAM ื”ื™ื™ืชื” ืœื™ ื”ื˜ื™ื” ืœืกื™ืกืงื•, ื›ื™ ื‘ืชืฆื•ืจื” ืžื™ืœืืชื™ โ€‹โ€‹ืืช ืขืจื•ืฆื™ ื‘ืงืจ ื”ื–ื™ื›ืจื•ืŸ ื‘ืื•ืคืŸ ืฉื•ื•ื”. ื”ืขืœื•ืช ืžืขื˜ ื’ื‘ื•ื”ื” ื™ื•ืชืจ, ืื‘ืœ ืœื ื‘ืกื“ืจ ื’ื•ื“ืœ, ืžื” ืฉืžืฆื‘ื™ืข ื‘ื‘ื™ืจื•ืจ ืขืœ ื›ืš ืฉื”ืชื›ื ืกื•ืช ื™ืชืจ ื”ื™ื ืœื ื‘ื”ื›ืจื— "ืฆืขืฆื•ืข ืœืขืฉื™ืจื™ื", ืืœื ื™ื›ื•ืœื” ืœื”ืชื—ืจื•ืช ื‘ื’ื™ืฉื” ื”ืกื˜ื ื“ืจื˜ื™ืช ืœื‘ื ื™ื™ืช ืžืจื›ื– ื ืชื•ื ื™ื. ื–ื” ืขืฉื•ื™ ืœืขื ื™ื™ืŸ ื’ื ืืช ืžื™ ืฉื›ื‘ืจ ื™ืฉ ืœื• ืฉืจืชื™ Cisco UCS ื•ืืช ื”ืชืฉืชื™ืช ื”ืžืชืื™ืžื” ืœื”ื.

ื‘ื™ืŸ ื”ื™ืชืจื•ื ื•ืช, ืื ื• ืžืงื‘ืœื™ื ืืช ื”ื™ืขื“ืจ ืขืœื•ื™ื•ืช ืขื‘ื•ืจ ื ื™ื”ื•ืœ SAN ื•ืžืขืจื›ื•ืช ืื—ืกื•ืŸ, ื“ื—ื™ืกื” ืžืงื•ื•ื ืช ื•ืžื ื™ืขืช ื›ืคื™ืœื•ืช, ื ืงื•ื“ืช ื›ื ื™ืกื” ืื—ืช ืœืชืžื™ื›ื” (ื•ื™ืจื˜ื•ืืœื™ื–ืฆื™ื”, ืฉืจืชื™ื, ื”ืŸ ื’ื ืžืขืจื›ื•ืช ืื—ืกื•ืŸ), ื—ื™ืกื›ื•ืŸ ื‘ืžืงื•ื (ืืš ืœื ื‘ื›ืœ ื”ืชืจื—ื™ืฉื™ื), ืคื™ืฉื•ื˜ ื”ืคืขื•ืœื”.

ืœื’ื‘ื™ ืชืžื™ื›ื”, ื›ืืŸ ืืชื” ืžืงื‘ืœ ืื•ืชื” ืžืกืคืง ืื—ื“ - ืกื™ืกืงื•. ืื ืœืฉืคื•ื˜ ืœืคื™ ื”ื ื™ืกื™ื•ืŸ ืฉืœื™ ืขื ืฉืจืชื™ Cisco UCS, ืื ื™ ืื•ื”ื‘ ืืช ื–ื”; ืœื ื”ื™ื™ืชื™ ืฆืจื™ืš ืœืคืชื•ื— ืื•ืชื• ื‘-HyperFlex, ื”ื›ืœ ืขื‘ื“ ื‘ื“ื™ื•ืง ืื•ืชื• ื”ื“ื‘ืจ. ืžื”ื ื“ืกื™ื ืžื’ื™ื‘ื™ื ืžื™ื™ื“ื™ืช ื•ื™ื›ื•ืœื™ื ืœืคืชื•ืจ ืœื ืจืง ื‘ืขื™ื•ืช ื˜ื™ืคื•ืกื™ื•ืช, ืืœื ื’ื ืžืงืจื™ ืงืฆื” ืžื•ืจื›ื‘ื™ื. ืœืคืขืžื™ื ืื ื™ ืคื•ื ื” ืืœื™ื”ื ื‘ืฉืืœื•ืช: "ื”ืื ืืคืฉืจ ืœืขืฉื•ืช ืืช ื–ื”, ืœื“ืคื•ืง ืืช ื–ื”?" ืื• "ื”ื’ื“ืจืชื™ ืžืฉื”ื• ื›ืืŸ, ื•ื”ื•ื ืœื ืจื•ืฆื” ืœืขื‘ื•ื“. ืขึถื–ืจึธื”!" - ื”ื ื™ืžืฆืื• ืฉื ื‘ืกื‘ืœื ื•ืช ืืช ื”ืžื“ืจื™ืš ื”ื“ืจื•ืฉ ื•ื™ืฆื‘ื™ืขื• ืขืœ ื”ืคืขื•ืœื•ืช ื”ื ื›ื•ื ื•ืช; ื”ื ืœื ื™ืขื ื•: "ืื ื—ื ื• ืคื•ืชืจื™ื ืจืง ื‘ืขื™ื•ืช ื—ื•ืžืจื”."

ืชื–ื›ื•ืจ

ืžืงื•ืจ: www.habr.com

ื”ื•ืกืคืช ืชื’ื•ื‘ื”