å°å ¥
ããã«ã¡ã¯ãåéïŒ [Extreme Networks](https://tssolution.ru/katalog/extreme) ã®ãããªãã³ããŒã®è£œåã«ç¹åãã Habré ã«é¢ããèšäºãããŸããªãããšã«æ°ã¥ããŠé©ããŸããã ãã®åé¡ãä¿®æ£ããExtreme 補åã©ã€ã³ããã詳ãã玹ä»ããããã«ãããã€ãã®èšäºãããªãçãã·ãªãŒãºãæžãäºå®ã§ããšã³ã¿ãŒãã©ã€ãºåãã¹ã€ããããå§ããããšæããŸãã
ãã®ã·ãªãŒãºã«ã¯æ¬¡ã®èšäºãå«ãŸããŸãã
- Extreme Enterprise ã¹ã€ããã®ã¬ãã¥ãŒ
- Extreme ã¹ã€ããã§ã®ãšã³ã¿ãŒãã©ã€ãº ãããã¯ãŒã¯èšèš
- ãšã¯ã¹ããªãŒã ã¹ã€ããèšå®ã®æ§æ
- Extreme ã¹ã€ãããšä»ã®ãã³ããŒã®æ©åšãšã®æ¯èŒã確èªãã
- Extreme ã¹ã€ããã®ä¿èšŒããã¯ãã«ã« ãµããŒããããã³ãµãŒãã¹å¥çŽ
ãã®ãã³ããŒã«èå³ããããã¹ãŠã®äººã
ããããŠåã«ãããã®ã¹ã€ããã®éžæãæ§æã«çŽé¢ããŠãããããã¯ãŒã¯ ãšã³ãžãã¢ããããã¯ãŒã¯ç®¡çè
ã«ããã®ã·ãªãŒãºã®èšäºããèªã¿ããã ãããšããå§ãããŸãã
ç§ãã¡ã«ã€ããŠ
ãŸãã¯ãåœç€Ÿã®æŠèŠãšãã®æãç«ã¡ã«ã€ããŠã玹ä»ãããŠããã ããŸãã
ãšã¯ã¹ããªãŒã ãããã¯ãŒã¯ ã¯ãé«åºŠãªã€ãŒãµãããæè¡ãœãªã¥ãŒã·ã§ã³ãæšé²ããã€ãŒãµãããæšæºãéçºããããã« 1996 幎ã«èšç«ãããéä¿¡äŒç€Ÿã§ãã ãããã¯ãŒã¯ ã¹ã±ãŒãªã³ã°ããµãŒãã¹å質ãé«éãªã«ããªã®åéã«ãããã€ãŒãµãããæšæºã®å€ãã¯ãExtreme Networks ã®å
¬éç¹èš±ã§ãã æ¬ç€Ÿã¯ç±³åœãµã³ã㌠(ã«ãªãã©ã«ãã¢å·) ã«ãããŸãã çŸæç¹ã§ã¯ãExtreme Networks ã¯ã€ãŒãµãããã®éçºã«ç¹åããå
¬éäŒç€Ÿã§ãã
2015幎1300ææç¹ã®åŸæ¥å¡æ°ã¯XNUMXåã
Extreme Networks ã¯ããŠãŒã¶ãŒãšããã€ã¹ã®çµ¶ãéãªã移åãããã³ããŒã¿ã»ã³ã¿ãŒå å€ã®ã¯ã©ãŠããžã®ä»®æ³ãã·ã³ã®ç§»è¡ã䌎ãä»æ¥ã®ã¢ãã€ã«äžçã®éèŠãæºããæç·ããã³ç¡ç·ãããã¯ãŒãã³ã° ãœãªã¥ãŒã·ã§ã³ãæäŸããŸãã ExtremeXOS ã䜿çšãããšãåäžã®ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã䜿çšããŠãéä¿¡äºæ¥è ãšããŒã¿ ã»ã³ã¿ãŒ ãããã¯ãŒã¯ãããã³ããŒã«ã«/ãã£ã³ãã¹ ãããã¯ãŒã¯ã®äž¡æ¹ã®ããã®é«åºŠãªãœãªã¥ãŒã·ã§ã³ãäœæã§ããŸãã
CIS ã®äŒæ¥ããŒãããŒ
- ãã·ã¢ã§ã¯ãExtreme Networks ã«ã¯ RRCãMarvelãOCS ã® 100 ã€ã®æ£èŠè²©å£²ä»£çåºããããããã« XNUMX ãè¶ ããããŒãããŒãããããã®æ°ã¯åžžã«å¢å ããŠããŸãã
- ãã©ã«ãŒã·ã§ã¯ãExtreme Networks ã«ã¯ SolidexãMUKãAbris ã® XNUMX ã€ã®æ£èŠä»£çåºããããŸãã Solidex 瀟ã¯èªå®ãã¬ãŒãã³ã° ããŒãããŒã®å°äœãæã£ãŠããŸãã
- ãŠã¯ã©ã€ãã«ã¯ããInformatsiyne Merezhivoããšããå ¬åŒä»£çåºã XNUMX ã€ãããŸãã
- äžå€®ã¢ãžã¢è«žåœããã³ãžã§ãŒãžã¢ãã¢ã«ã¡ãã¢ãã¢ãŒã«ãã€ãžã£ã³ã§ã¯ãRRC ããã³ Abris ãæ£èŠä»£çåºã§ãã
ããŠãäŒè°ã¯çµãããŸããã次ã«ããã®ãã³ããŒããšã³ã¿ãŒãã©ã€ãº ãããã¯ãŒã¯çšã«ã©ã®ãããªã¹ã€ãããæäŸã§ããããèŠãŠã¿ãŸãããã
ãããŠåœŒã¯ç§ãã¡ã«æ¬¡ã®ãããªããšãææ¡ããŠãããã§ãããã
äžã®å³ã¯ãã¹ã€ãããå¶åŸ¡ãããªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã®çš®é¡ãšãããŒãã§ãµããŒããããŠãããã¯ãããžãŒã«å¿ããã¹ã€ãã ã¢ãã«ã瀺ããŠããŸã (å·ŠåŽã®åçŽç¢å°)ã
- 1ã®ã¬ãããã€ãŒãµããã
- 10ã®ã¬ãããã€ãŒãµããã
- 40ã®ã¬ãããã€ãŒãµããã
- 100ã®ã¬ãããã€ãŒãµããã
V400 ã·ãªãŒãºããå§ããŠãExtreme ã¹ã€ããã詳ããèŠãŠã¿ãŸãããã
V400ã·ãªãŒãºã¹ã€ãã
ãããã¯ãä»®æ³ããŒãæ¡åŒµãã¯ãããžãŒ (IEE 802.1BR ä»æ§ã«åºã¥ã) ã䜿çšããã¹ã€ããã§ãã ã¹ã€ããèªäœã¯ãä»®æ³ããŒã ãšã¯ã¹ãã³ããŒãšåŒã°ããŸãã
ãã®ãã¯ãããžãŒã®æ¬è³ªã¯ããã¹ãŠã®å¶åŸ¡ããã³ããŒã¿ãã¬ãŒã³ã®æ©èœãã¹ã€ããèªäœããã¢ã°ãªã²ãŒã·ã§ã³ ã¹ã€ãã (ã³ã³ãããŒã©ãŒ ããªããž/CB) ã«è»¢éãããããšã§ãã
ã³ã³ãããŒã© ããªããž ã¹ã€ãããšããŠäœ¿çšã§ããã®ã¯ã次ã®ã¢ãã«ã®ã¹ã€ããã®ã¿ã§ãã
- x590
- x670-G2
- x620-G2
ãããã®ã¹ã€ãããæ¥ç¶ããããã®äžè¬çãªåè·¯ã説æããåã«ããã®ä»æ§ã«ã€ããŠèª¬æããŸãã
äžã®è¡šãããããããã«ãã¹ã€ããã«ã¯ GE ã¢ã¯ã»ã¹ ããŒãã®æ° (24 ãŸã㯠48) ã«å¿ããŠã2 ã€ãŸã㯠4 ã€ã® 10GE SFP+ ã¢ãããªã³ã¯ ããŒãããããŸãã
802.3af (ããŒããããæ倧 15 W) ããã³ 802.3at (ããŒããããæ倧 30 W) ãã¯ãããžãŒã䜿çšã㊠PoE ããã€ã¹ã«æ¥ç¶ããé»åãäŸçµŠããããã® PoE ããŒããåããã¹ã€ããããããŸãã
以äžã¯ãV4 ããã³ CB ã¹ã€ããã® 400 ã€ã®äžè¬çãªæ¥ç¶å³ã§ãã
ä»®æ³ããŒãæ¡åŒµãã¯ãããžãŒã®å©ç¹:
- ã¡ã³ããã³ã¹ã®å®¹æã - V400 ã¹ã€ããã® XNUMX ã€ãæ éããå Žåãããã亀æããã ãã§ååã§ãããæ°ããã¹ã€ãããèªåçã«æ€åºãããCB åäœçšã«èšå®ãããŸãã ããã«ãããåã¢ã¯ã»ã¹ ã¹ã€ãããèšå®ããå¿ èŠããªããªããŸãã
- æ§æå šäœã¯ CB äžã«ã®ã¿é 眮ãããV400 ã¹ã€ããã¯è¿œå ã® CB ããŒããšããŠã®ã¿è¡šç€ºãããããããããã®ã¹ã€ããã®ç®¡çãç°¡çŽ åãããŸãã
- V400 ãã³ã³ãããŒã© ããªããžãšçµã¿åãããŠäœ¿çšââãããšãV400 ã¹ã€ããã§ã³ã³ãããŒã© ããªããžã®ãã¹ãŠã®æ©èœãå©çšã§ããŸãã
ãã¯ãããžãŒã®å¶é - V48 ã¹ã€ããã®æ倧 400 åã®ããŒã ãšã¯ã¹ãã³ã㌠(2300 ã¢ã¯ã»ã¹ ããŒã) ããµããŒããããŸãã
X210 ããã³ X220 ã·ãªãŒãº ã¹ã€ãã
E200 ãã¡ããªã®ã¹ã€ããã¯ãåºå®æ°ã® 10/100/1000 BASE-T ããŒããåããL2/L3 ã¬ãã«ã§åäœãããšã³ã¿ãŒãã©ã€ãº ã¢ã¯ã»ã¹ ã¹ã€ãããšããŠäœ¿çšããããšãç®çãšããŠããŸãã ã¢ãã«ã«å¿ããŠãã¹ã€ããã«ã¯æ¬¡ã®æ©èœããããŸãã
- PoE/PoE+ ããŒã
- 2 ãŸã㯠4 åã® 10 GE SFP+ ããŒã (X220 ã·ãªãŒãº)
- ã¹ã¿ããã³ã°ã®ãµããŒã - ã¹ã¿ãã¯å ã§æ倧 4 ã€ã®ã¹ã€ãã (X220 ã·ãªãŒãº)
以äžã«ãX200 ã·ãªãŒãº ã¹ã€ããã®æ§æãšããã€ãã®æ©èœããŸãšããè¡šã瀺ããŸãã
è¡šãããããããã«ãE210 ããã³ E220 ã·ãªãŒãº ã¹ã€ããã¯ã¢ã¯ã»ã¹ ã¹ã€ãããšããŠäœ¿çšããããã«èšèšãããŠããŸãã 10 GE SFP+ ããŒãã®ååšã«ãããX220 ã·ãªãŒãº ã¹ã€ããã¯ã¹ã¿ãã¯åž¯åå¹
4 Gb ã§ã¹ã¿ãã¯ãããæ倧 40 ãŠãããã®ã¹ã¿ããã³ã°ããµããŒãã§ããŸãã
ã¹ã€ãã㯠EOS ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã«ãã£ãŠç®¡çãããŸãã
ERS ã·ãªãŒãº ã¹ã€ãã
ãã®ã·ãªãŒãºã®ã¹ã€ããã¯ãè¥ã E200 ã·ãªãŒãºã®ã¹ã€ãããšæ¯ã¹ãŠçç£æ§ãé«ããªããŸãã
ãŸã第äžã«ã泚ç®ãã¹ãç¹ã¯æ¬¡ã®ãšããã§ãã
- ãããã®ã¹ã€ããã«ã¯ãããé«åºŠãªã¹ã¿ããã³ã°æ©èœããããŸãã
- ã¹ã¿ãã¯å ã«æ倧 8 ã€ã®ã¹ã€ãã
- ã¢ãã«ã«å¿ããŠãSFP+ ããŒããšã¹ã¿ããã³ã°å°çšããŒãã®äž¡æ¹ã䜿çšã§ããŸã
- ERS ã·ãªãŒãº ã¹ã€ããã¯ãE200 ã·ãªãŒãºãšæ¯èŒããŠããã倧ã㪠PoE ããžã§ãããåããŠããŸã
- ERS ã·ãªãŒãº ã¹ã€ããã¯ãE3 ã·ãªãŒãºãšæ¯èŒããŠå¹ åºã L200 æ©èœãåããŠããŸã
ãžã¥ã㢠ã©ã€ã³ã§ãã ERS3600 ãã ERS ââã¹ã€ãã ãã¡ããªã®ãã詳现ãªã¬ãã¥ãŒãéå§ããããšããå§ãããŸãã
ERS3600ã·ãªãŒãº
ãã®ã·ãªãŒãºã®ã¹ã€ããã¯æ¬¡ã®æ§æã§æäŸãããŸãã
è¡šãããããããã«ãERS 3600 ã¹ã€ããã¯ã¢ã¯ã»ã¹ ã¹ã€ãããšããŠäœ¿çšã§ããã¹ã¿ãã¯å®¹éã倧ãããPoE ããžã§ããã倧ãããå¹
åºã L3 æ©èœãåããŠããŸãããã ãããã¡ãããå¶éãããã®ã¯ RIP v1/v2 ãã€ããã㯠ã«ãŒãã£ã³ã°ã®ã¿ã§ãããããã³ã«ãããã³ãã€ãèªã«é¢é£ããã€ã³ã¿ãŒãã§ã€ã¹ãšã«ãŒãã®æ°
äžã®å³ã¯ã50 ããŒã ERS3600 ã·ãªãŒãº ã¹ã€ããã®åé¢å³ãšèé¢å³ã瀺ããŠããŸãã
ERS4900ã·ãªãŒãº
ERS4900 ã·ãªãŒãº ã¹ã€ããã®æ§æãšæ©èœã次ã®è¡šã«ç°¡åã«èª¬æããŸãã
ã芧ã®ãšããããããã®ã¹ã€ãã㯠RIPv1/2 ã OSPF ãªã©ã®åçã«ãŒãã£ã³ã° ãããã³ã«ãå®è£
ããŠãããã²ãŒããŠã§ã€åé·ãããã³ã«ã§ãã VRRP ããããIPv6 ãããã³ã«ããµããŒãããŠããŸãã
ããã§éèŠãªæ³šæäºé ãè¿°ã¹ãªããã°ãªããŸããã* è¿œå ã® L2 ããã³ L3 æ©èœ (OSPFãVRRPãECMPãPIM-SMãPIMSSM/PIM-SSMãIPv6 ã«ãŒãã£ã³ã°) ã¯ãè¿œå ã®ã©ã€ã»ã³ã¹ã§ããã¢ããã³ã¹ã ãœãããŠã§ã¢ ã©ã€ã»ã³ã¹ãè³Œå ¥ããããšã§æå¹ã«ãªããŸãã
äžã®åçã¯ã26 ããŒã ERS4900 ã·ãªãŒãº ã¹ã€ããã®åé¢å³ãšèé¢å³ãããã³ããããã¹ã¿ãã¯ãããªãã·ã§ã³ã瀺ããŠããŸãã
åçãããããããã«ãERS4900 ã·ãªãŒãº ã¹ã€ããã«ã¯ã¹ã¿ããã³ã°çšã®å°çšããŒã (ã«ã¹ã±ãŒã ã¢ãã/ã«ã¹ã±ãŒã ããŠã³) ããããåé·é»æºãè£
åããããšãã§ããŸãã
ERS5900ã·ãªãŒãº
ERS ã·ãªãŒãºã®ææ°ãã€æäžçŽã®ã¢ãã«ã¯ãERS5900 ã¹ã€ããã§ãã
é¢çœãããïŒ
- ã·ãªãŒãºã®äžéšã®ã¹ã€ããã¯ãŠãããŒãµã« PoE ãåããŠãããå°çšããã€ã¹ãå°åã¹ã€ãã/ã«ãŒã¿ãŒã«é»åãäŸçµŠããããã«ããŒãããã 60 W ãåºåã§ããŸãã
- åèš 100 kW ã® PoE ããžã§ãããæ〠2,8 ããŒãã®ã¹ã€ããããããŸã
- 2.5GBASE-TïŒ802.3bzèŠæ ŒïŒããµããŒãããããŒããã
- MACsec æ©èœ (802.1AE æšæº) ã®ãµããŒã
ã·ãªãŒãº ã¹ã€ããã®æ§æãšæ©èœã¯ã次ã®è¡šã§æããã説æãããŠããŸãã
* 5928GTS-uPWR ããã³ 5928MTS-uPWR ã¹ã€ããã¯ããããã 60 ã㢠PoE ã€ãã·ã¢ãã (å¥åãŠãããŒãµã« PoE - uPoE) ããµããŒãããŠããŸããããã¯ãã¢ã¯ã»ã¹ ããŒãã§æ倧 XNUMX W ãæ¶è²»ããããã€ã¹ã«é»åãäŸçµŠããæ©èœã§ããåçš®ã®ãããªéä¿¡ã·ã¹ãã ãã¢ãã¿ãŒä»ãã® VDI ã·ã³ ã¯ã©ã€ã¢ã³ããPoE é»æºä»ãã®å°åã¹ã€ãããŸãã¯ã«ãŒã¿ãŒãããã«ã¯äžéšã® IoT ãã¯ãããžãŒ ã·ã¹ãã (ã€ã³ããªãžã§ã³ãç
§æå¶åŸ¡ã·ã¹ãã ãªã©) ãå«ãŸããŸãã
** 1440 ã€ã®é»æºè£
眮ãèšçœ®ãããšã2 W ã® PoE ããžã§ãããéæãããŸãã ã¹ã€ããã« 1 ã€ã®é»æºè£
眮ãåãä»ããå ŽåãPoE ããžã§ãã㯠1200 W ã«ãªããŸãã
*** é»æºè£
眮ã 2880 ã€èšçœ®ãããšã4 W ã® PoE ããžã§ãããéæãããŸãã ã¹ã€ããã« 1 ã€ã®é»æºè£
眮ãåãä»ããå ŽåãPoE ããžã§ãã㯠1200 W ã«ãªããŸãã ã¹ã€ããã« 2 ã€ã®é»æºè£
眮ãåãä»ããå ŽåãPoE ããžã§ãã㯠2580 W ã«ãªããŸãã
ERS2 ã·ãªãŒãºã®å Žåãšåæ§ã«ãè¿œå ã® L3 ããã³ L4900 æ©èœã¯ãã¹ã€ããã®é©åãªã©ã€ã»ã³ã¹ãè³Œå ¥ããŠã¢ã¯ãã£ãåããããšã§æäŸãããŸãã
以äžã®åçã¯ã100 ããŒã ERS5900 ã·ãªãŒãº ã¹ã€ããã®åé¢å³ãšèé¢å³ãããã³ 28 ããŒã ã¹ã€ãããš 52 ããŒã ã¹ã€ããã®ã¹ã¿ããã³ã° ãªãã·ã§ã³ã瀺ããŠããŸãã
**ãã¹ãŠã®ã·ãªãŒãº ã¹ã€ããã¯ãERS ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã«ãã£ãŠç®¡çãããŸãã**
ãæ°ã¥ãããšæããŸããããã®ã·ãªãŒãºã®èª¬æã®æåŸã«ãã©ã®ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã«ãã£ãŠå¶åŸ¡ãããŠãããã瀺ããŠããŸããããã«ã¯çç±ããããŸãã ãã§ã«å€ãã®äººãæšæž¬ããŠããããã«ãå®éã«ã¯ãç¹å®ã®ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã管çãããšããããšã¯ãåãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã®æ§æã³ãã³ããšèšå®ãããã¯ã®åå¥ã®ã»ãããæå³ããŸãã
äŸïŒ
Avaya ã¹ã€ããã®ãã¡ã³ãªããæ°ã¥ãããšæããŸãããERS ã·ãªãŒãº ã¹ã€ããã® L2 æ©èœã®èª¬æã« MLT/LACP ã°ã«ãŒããšããè¡ããããŸããããã¯ãã€ã³ã¿ãŒãã§ã€ã¹ãçµåããããã®ã°ã«ãŒãã®æ倧æ°ãç¹åŸŽã¥ããŸã (éä¿¡ãªã³ã¯ã®éçŽãšåé·æ§)ã ïŒã MLT ã®æå®ã¯ãAvaya Holding ã補é ããã¹ã€ããã®ãªã³ã¯ ã¢ã°ãªã²ãŒã·ã§ã³ã«åºæã§ããããªã³ã¯ ã¢ã°ãªã²ãŒã·ã§ã³ãæ§æãããšãã«ã³ãã³ãæ§æã§çŽæ¥äœ¿çšãããŸãã
åé¡ã¯ãExtremeNetworks ãéçºæŠç¥ã«åŸã£ãŠã2017 幎ãã 2018 幎ã«ãã㊠Avaya Holdings ãè²·åããããšã§ããAvaya Holdings ã¯åœæãç¬èªã®ã¹ã€ããã®è£œåã©ã€ã³ãæã£ãŠããŸããã ãããã£ãŠãERS ã·ãªãŒãºã¯æ¬è³ªçã« Avaya ã¹ã€ãã ã·ãªãŒãºã®ç¶ç¶ã§ãã
EXOSã·ãªãŒãºã¹ã€ãã
EXOS ã·ãªãŒãºã¯ãExtreme ã·ãªãŒãºã®ããã©ãã°ã·ããããšèããããŠããŸãã ãã®ã©ã€ã³ã®ã¹ã€ããã¯ãå€ãã®æšæºãããã³ã«ãšå€ãã®ãç¬èªã®ãExtreme ãããã³ã«ã®äž¡æ¹ã®æã匷åãªæ©èœãå®è£ ããŠããŸããããã«ã€ããŠã¯åŸã§èª¬æããŸãã
ãã®äžã«ã¯ããããã奜ã¿ã«åãããã¹ã€ããããããŸãã
- ãããããããã¯ãŒã¯ ã¬ãã« - ããŒã¿ã»ã³ã¿ãŒã®ã¢ã¯ã»ã¹ãã¢ã°ãªã²ãŒã·ã§ã³ãã³ã¢ãã¹ã€ããã«å¯Ÿå¿
- ä»»æã®ããŒã ã»ãã 10/100/1000 Base-TãSFPãSFP+ãQSFPãQSFP+
- PoE ãµããŒãã®æç¡ã«ããããã
- éèŠãªãããã¯ãŒã¯ ããŒãã®ãã©ãŒã«ã ãã¬ã©ã³ã¹ã確ä¿ããããã®ãããã€ãã®ã¿ã€ãã®ãã¹ã¿ããã³ã°ããšãã¯ã©ã¹ã¿ãªã³ã°ãã®ãµããŒã
ãã®ã·ãªãŒãºã®æãè¥ã補åã§ãã X440 ã®ã¬ãã¥ãŒãå§ããåã«ãEXOS ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã®ã©ã€ã»ã³ã¹ ããªã·ãŒã«ã€ããŠèª¬æããããšæããŸãã
EXOS ã©ã€ã»ã³ã¹ (ããŒãžã§ã³ 22.1 以é)
EXOS ã«ã¯ããšããž ã©ã€ã»ã³ã¹ãã¢ããã³ã¹ã ãšããž ã©ã€ã»ã³ã¹ãã³ã¢ ã©ã€ã»ã³ã¹ã® 3 ã€ã®äž»ãªã©ã€ã»ã³ã¹ããããŸãã
次ã®è¡šã¯ãEXOS ã·ãªãŒãº ã¹ã€ãã ã©ã€ã³ã«å¿ããã©ã€ã»ã³ã¹äœ¿çšãªãã·ã§ã³ã瀺ããŠããŸãã
- Standard ã¯ãã¹ã€ããã«æšæºã§ä»å±ãããªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã® EXOS ããŒãžã§ã³ã§ãã
- ã¢ããã°ã¬ãŒãã¯ãEXOS ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ãä»»æã®ã¬ãã«ã«æ¡åŒµããæ©èœã§ãã
åã¿ã€ãã®ã©ã€ã»ã³ã¹ã®æ©èœãšãã·ãªãŒãºã®ããŸããŸãªãã©ãããã©ãŒã ã§ã®ãµããŒãã以äžã®è¡šã«ç€ºããŸãã
ãšããžã©ã€ã»ã³ã¹
ExtremeXOS ãœãããŠã§ã¢ã®æ©èœ
ãµããŒããããŠãããã©ââãããã©ãŒã
EDP
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãšã¯ã¹ããªãŒã ãããã¯ãŒã¯ä»®æ³å (XNV)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ã¢ã€ãã³ãã£ãã£ç®¡ç
ãã¹ãŠã®ãã©ãããã©ãŒã ã
LLDP 802.1ab
ãã¹ãŠã®ãã©ãããã©ãŒã ã
LLDP-MED æ¡åŒµ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VLAN - ããŒãããŒã¹ã®ã¿ã°ä»ããã©ã³ã¯
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VLAN - MAC ããŒã¹
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VLAN - ãããã³ã«ããŒã¹
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VLAN - ãã©ã€ããŒã VLAN
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VLAN - VLAN å€æ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VMAN - Q-in-Q ãã³ããªã³ã° (IEEE 802.1ad VMAN ãã³ããªã³ã°æšæº)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VMAN - S ã¿ã°ã® 802.1p å€ã«åºã¥ãåºåãã¥ãŒã®éžæ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VMAN - C ã¿ã°ã® 802.1p å€ã«åºã¥ãåºåãã¥ãŒã®éžæ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VMAN - ã»ã«ã³ã㪠ã€ãŒãµã¿ã€ãã®ãµããŒã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VMAN ã«ã¹ã¿ã㌠ãšããž ããŒã (CEP - Selective Q-in-Q ãšãåŒã°ããŸã)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VMAN ã«ã¹ã¿ã㌠ãšããž ããŒã CVID Egress ãã£ã«ã¿ãªã³ã° / CVID å€æ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VMAN - CNP ããŒã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VMAN - CNP ããŒããäºéã¿ã°ã®ãµããŒã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
VMAN - CNP ããŒããåºåãã£ã«ã¿ãªã³ã°ãåããäºéã¿ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
L2 Ping / ãã¬ãŒã¹ã«ãŒã 802.1ag
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãžã£ã³ã ãã¬ãŒã (ãã¹ãŠã®é¢é£ã¢ã€ãã ãMTU ãã£ã¹ã¯ãIP ãã©ã°ãå«ã)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
QoS - åºåããŒãã®ã¬ãŒãã·ã§ãŒãã³ã°/å¶é
ãã¹ãŠã®ãã©ãããã©ãŒã ã
QoS - åºåãã¥ãŒã®ã¬ãŒãã·ã§ãŒãã³ã°/å¶é
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãªã³ã¯ ã¢ã°ãªã²ãŒã·ã§ã³ ã°ã«ãŒã (LAG)ãéç 802.3ad
ãã¹ãŠã®ãã©ãããã©ãŒã ã
LAG åç (802.3ad LACP) ãšããžããµãŒããŒã®ã¿!
ãã¹ãŠã®ãã©ãããã©ãŒã ã
LAG (802.3ad LACP) ã³ã¢ãã¹ã€ããé
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ããŒãã®ã«ãŒãããã¯ã®æ€åºãšã·ã£ããããŠã³ (ELRP CLI)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãœãããŠã§ã¢åé·ããŒã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
STP 802.1D
ãã¹ãŠã®ãã©ãããã©ãŒã ã
STP EMISTP + PVST+ äºæã¢ãŒã (ããŒãããšã« 1 ãã¡ã€ã³)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
STP EMISTPãPVST+ ãã« (ãã«ããã¡ã€ã³ ãµããŒã)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
STP 802.1
ãã¹ãŠã®ãã©ãããã©ãŒã ã
STP802.1w
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ERPS (äžèŽãããªã³ã° ããŒããåããæ倧 4 ã€ã®ãªã³ã°)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ESRP察å¿
ãã¹ãŠã®ãã©ãããã©ãŒã ã
EAPS ãšããž (äžèŽãããªã³ã° ããŒããæã€æ倧 4 ã€ã®ãã¡ã€ã³)
泚: Advanced Edge ã©ã€ã»ã³ã¹ã«ã¢ããã°ã¬ãŒããããšããã¡ã€ã³ã®æ°ãå¢ããããšãã§ããŸã (ãAdvanced Edge ã©ã€ã»ã³ã¹ããåç
§)ã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãªã³ã¯é害ã·ã°ããªã³ã°ïŒLFSïŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ELSM (ãšã¯ã¹ããªãŒã ãªã³ã¯ ã¹ããŒã¿ã¹ ã¢ãã¿ãªã³ã°)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ACLãå ¥åããŒãã«é©çšããã
- IPv4
- éç
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ACLãå ¥åããŒãã«é©çšããã
- IPv6
- ãã€ãããã¯
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ACLãåºåããŒãã«é©çšããã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ACLãã€ã³ã°ã¬ã¹ã¡ãŒã¿ãŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ACLãåºåã¡ãŒã¿ãŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ACL
- ã¬ã€ã€ 2 ãããã³ã« ãã³ããªã³ã°
- ãã€ãã«ãŠã³ã¿ãŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ã³ã³ããŒãžã§ã³ã¹ãšã³ããã€ã³ãïŒCEPïŒæ€åº
ãã¹ãŠã®ãã©ãããã©ãŒã ã
CPU DoS ä¿è·
ãã¹ãŠã®ãã©ãããã©ãŒã ã
CPUç£èŠ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãã€ã¬ã¯ã ã¢ã¿ãã - IEEE ããŒãžã§ã³ã® VEPA ã«åºã¥ããŠãããä»®æ³ã¹ã€ããå±€ãäžèŠã«ãªãããããã¯ãŒã¯ãç°¡çŽ åãããããã©ãŒãã³ã¹ãåäžããŸãã ãã€ã¬ã¯ã ã¢ã¿ããã䜿çšãããšãããŒã¿ ã»ã³ã¿ãŒã®èŠæš¡ã«å¿ããŠããããã¯ãŒã¯å±€ã XNUMX å±€ãŸã㯠XNUMX å±€ãã XNUMX å±€ãŸã㯠XNUMX å±€ã«æžããããšã§ãããŒã¿ ã»ã³ã¿ãŒãç°¡çŽ åã§ããŸãã
ãã¹ãŠã®ãã©ãããã©ãŒã
SNMPv3
ãã¹ãŠã®ãã©ãããã©ãŒã ã
SSH2ãµãŒããŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
SSH2ã¯ã©ã€ã¢ã³ã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
SCP/SFTPã¯ã©ã€ã¢ã³ã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
SCP/SFTPãµãŒããŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ã³ãã³ãèªèšŒããšã® RADIUS ããã³ TACACS+
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãããã¯ãŒã¯ãã°ã€ã³
- ãŠã§ãããŒã¹ã®æ¹æ³
- 802.1Xæ¹åŒ
- MACããŒã¹ã®æ¹æ³
- MAC/Web ããŒã¹ã®ã¡ãœããçšã®ããŒã«ã« ããŒã¿ããŒã¹
- Microsoft NAPãšã®çµ±å
- è€æ°ã®ãµããªã«ã³ã - åã VLAN
- Web ããŒã¹ã®ã¡ãœããã® HTTPS/SSL
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãããã¯ãŒã¯ ãã°ã€ã³ - è€æ°ã®ãµããªã«ã³ã - è€æ°ã® VLAN
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ä¿¡é Œã§ããOUI
ãã¹ãŠã®ãã©ãããã©ãŒã ã
MAC ã»ãã¥ãªãã£
- ããã¯ããŠã³
- ãªããã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IP ã»ãã¥ãªã㣠- DHCP ãªãã·ã§ã³ 82 - L2 ã¢ãŒã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IP ã»ãã¥ãªã㣠- DHCP ãªãã·ã§ã³ 82 - L2 ã¢ãŒã VLAN ID
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IP ã»ãã¥ãªã㣠- DHCP IP ããã¯ããŠã³
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IP ã»ãã¥ãªã㣠- ä¿¡é Œããã DHCP ãµãŒã㌠ããŒã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
éç IGMP ã¡ã³ããŒã·ãããIGMP ãã£ã«ã¿ãŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv4ãŠããã£ã¹ãL2ã¹ã€ããã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv4ãã«ããã£ã¹ãL2ã¹ã€ããã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv4 ãã€ã¬ã¯ããããŒããã£ã¹ã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv4
- é«éãã€ã¬ã¯ããããŒããã£ã¹ã
- ãããŒããã£ã¹ããç¡èŠãã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv6ãŠããã£ã¹ãL2ã¹ã€ããã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv6ãã«ããã£ã¹ãL2ã¹ã€ããã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv6 netTools - PingãtracerouteãBOOTP ãªã¬ãŒãDHCPãDNSãããã³ SNTPã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv4 netTools - PingãtracerouteãBOOTP ãªã¬ãŒãDHCPãDNSãNTPãããã³ SNTPã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IGMP v1/v2 ã¹ããŒãã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IGMP v3 ã¹ããŒãã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãã«ããã£ã¹ãVLANç»é²ïŒMVRïŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
éç MLD ã¡ã³ããŒã·ãããMLD ãã£ã«ã¿ãŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
MLD v1 ã¹ããŒãã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
MLD v2 ã¹ããŒãã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
sFlowã¢ã«ãŠã³ãã£ã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
CLI ã¹ã¯ãªãã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
WebããŒã¹ã®ããã€ã¹ç®¡ç
ãã¹ãŠã®ãã©ãããã©ãŒã ã
Web ããŒã¹ã®ç®¡ç - HTTPS/SSL ãµããŒã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
XML API (ããŒãããŒçµ±åçš)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
MIB - ãšã³ãã£ãã£ãã€ã³ãã³ããªçš
ãã¹ãŠã®ãã©ãããã©ãŒã ã
æ¥ç¶é害管ç (CFM)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãªã¢ãŒãã»ãã©ãŒãªã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
åºåãã©ãŒãªã³ã°
ãã¹ãŠã®ãã©ãããã©ãŒã ã
Y.1731æºæ ã®ãã¬ãŒã é
延ããã³é
延åæ£ã®æž¬å®
ãã¹ãŠã®ãã©ãããã©ãŒã ã
MVRP - VLAN ããããžç®¡ç
ãã¹ãŠã®ãã©ãããã©ãŒã ã
EFM OAM - åæ¹åãªã³ã¯é害管ç
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ã¯ãªã¢ãããŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ã·ã¹ãã ä»®æ³ã«ãŒã¿ãŒ (VR)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
DHCPv4:
- DHCPv4ãµãŒããŒ
- DHCv4 ã¯ã©ã€ã¢ã³ã
- DHCPv4ãªã¬ãŒ
- DHCPv4 ã¹ããŒã ãªã¬ãŒ
- DHCPv6ãªã¢ãŒãID
ãã¹ãŠã®ãã©ãããã©ãŒã ã
DHCPv6:
- DHCPv6ãªã¬ãŒ
- DHCPv6 ãã¬ãã£ãã¯ã¹å§ä»»ã¹ããŒãã³ã°
- DHCPv6 ã¯ã©ã€ã¢ã³ã
- DHCPv6 ã¹ããŒã ãªã¬ãŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãŠãŒã¶ãŒäœæã®ä»®æ³ã«ãŒã¿ãŒ (VR)
ä»®æ³ã«ãŒã¿ãŒããã³è»¢é (VRF)
Summit X450-G2ãX460-G2ãX670-G2ãX770ãããã³ ExtremeSwitching X870ãX690
VLAN ã¢ã°ãªã²ãŒã·ã§ã³
ãã¹ãŠã®ãã©ãããã©ãŒã ã
転éã®ããã®ãã«ããããå
ãã¹ãŠã®ãã©ãããã©ãŒã ã
UDP転é
ãã¹ãŠã®ãã©ãããã©ãŒã ã
UDP BootP ãªã¬ãŒè»¢é
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv4 ãŠããã£ã¹ã ã«ãŒãã£ã³ã° (éçã«ãŒããå«ã)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv4 ãã«ããã£ã¹ã ã«ãŒãã£ã³ã° (éçã«ãŒããå«ã)
泚: ãã®æ©èœã«ã¯ãEdge ããã³ Advanced Edge ã©ã€ã»ã³ã¹ã®å¶éããããŸãã ããŸããŸãª EXOS ããŒãžã§ã³ã®è©³çŽ°ã«ã€ããŠã¯ããŠãŒã¶ãŒ ã¬ã€ããåç
§ããŠãã ããã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv4 éè€ã¢ãã¬ã¹æ€åº (DAD)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv6 ãŠããã£ã¹ã ã«ãŒãã£ã³ã° (éçã«ãŒããå«ã)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv6 ã€ã³ã¿ãŒã¯ãŒãã³ã° - IPv6-to-IPv4 ããã³ IPv6-in-IPv4 ã§æ§æããããã³ãã«
X620 ãš X440-G2 ãé€ããã¹ãŠã®ãã©ãããã©ãŒã ã
CLI 管çã䜿çšããªã IPv6 éè€ã¢ãã¬ã¹æ€åº (DAD)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
CLI 管çã«ãã IPv6 éè€ã¢ãã¬ã¹æ€åº (DAD)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPã»ãã¥ãªãã£:
- DHCP ãªãã·ã§ã³ 82 - L3 ã¢ãŒã
- DHCP ãªãã·ã§ã³ 82 - L3 ã¢ãŒã VLAN ID
- ARPåŠç¿ãç¡å¹ã«ãã
- ç¡åã® ARP ä¿è·
- DHCP ã§ä¿è·ããã ARP / ARP æ€èšŒ
- éä¿¡å IPããã¯ããŠã³
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPã¢ãã¬ã¹ã®ã»ãã¥ãªãã£:
- DHCPã¹ããŒãã³ã°
- ä¿¡é Œã§ãã DHCP ãµãŒããŒ
- éä¿¡å IPããã¯ããŠã³
- ARPæ€èšŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPãããŒæ
å ±ãšã¯ã¹ããŒã(IPFIX)
ãµãããX460-G2ã
ãã«ãã¹ã€ãã ãªã³ã¯ ã¢ã°ãªã²ãŒã·ã§ã³ ã°ã«ãŒã (MLAG)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ONEããªã·ãŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv4 ã®ããªã·ãŒããŒã¹ ã«ãŒãã£ã³ã° (PBR)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
IPv6 ã®ããªã·ãŒããŒã¹ ã«ãŒãã£ã³ã° (PBR)
ãã¹ãŠã®ãã©ãããã©ãŒã ã
PIMã¹ããŒãã³ã°
泚: ãã®æ©èœã«ã¯ãEdge ããã³ Advanced Edge ã©ã€ã»ã³ã¹ã®å¶éããããŸãã ããŸããŸãª EXOS ããŒãžã§ã³ã®è©³çŽ°ã«ã€ããŠã¯ããŠãŒã¶ãŒ ã¬ã€ããåç
§ããŠãã ããã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãããã³ã«ããŒã¹ã®VLAN
ãã¹ãŠã®ãã©ãããã©ãŒã ã
RIP v1/v2
ãã¹ãŠã®ãã©ãããã©ãŒã ã
RIPäž
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ã«ãŒãã£ã³ã°ã¢ã¯ã»ã¹ããªã·ãŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ã«ãŒãããã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãŠãããŒãµã« ããŒã - VoIP èªåèšå®
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãŠãããŒãµã« ããŒã - åçãªãŠãŒã¶ãŒããŒã¹ã®ã»ãã¥ãªã㣠ããªã·ãŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ãŠãããŒãµã« ããŒã - æå»ããªã·ãŒ
ãã¹ãŠã®ãã©ãããã©ãŒã ã
SummitStack (ãã€ãã£ããŸãã¯å°çšããŒãã䜿çšããã¹ã€ãã ã¹ã¿ããã³ã°)
X460-G2-VIM-460SS ãªãã·ã§ã³ ã«ãŒããåãã Summit X2-G2ãããã³ X450-G2ã
SummitStack-V (ãã¥ã¢ã«ããŒãã¹ ããŒã¿ ããŒãã䜿çšããã¹ã€ãã ã¹ã¿ããã³ã°)
ãã¹ãŠã®ãã©ãããã©ãŒã ã ãŠãŒã¶ãŒ ã¬ã€ãã®ã代æ¿ã¹ã¿ããã³ã° ããŒãã®ãµããŒããã»ã¯ã·ã§ã³ã«ãªã¹ããããŠããç¹å®ã®ã¢ãã«ãåç
§ããŠãã ããã
åæ
ãµãããX460-G2ã
Pythonã¹ã¯ãªãã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ã¢ããã³ã¹ããšããžã©ã€ã»ã³ã¹
ExtremeXOS ãœãããŠã§ã¢ã®æ©èœ
ãµããŒããããŠãããã©ââãããã©ãŒã
EAPS Advanced Edge - è€æ°ã®ç©çãªã³ã°ãããã³ãå
±æããŒãããšãåŒã°ãããå
±éãªã³ã¯ãã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ERPS-more ãã¡ã€ã³ (äžèŽãããªã³ã° ããŒã㧠32 åã®ãªã³ã°ãèš±å¯) ããã³ãã«ããªã³ã°ã®ãµããŒã
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ESRP-ãã«
ãã¹ãŠã®ãã©ãããã©ãŒã ã
ESRP-ä»®æ³MAC
ãã¹ãŠã®ãã©ãããã©ãŒã ã
OSPFv2-Edge (ã¢ã¯ãã£ããªã€ã³ã¿ãŒãã§ã€ã¹ã¯æ倧 4 ã€ã«å¶é)
Advanced Edge ãŸã㯠Core ã©ã€ã»ã³ã¹ããµããŒããããã¹ãŠã®ãã©ãããã©ãŒã
OSPFv3-Edge (ã¢ã¯ãã£ããªã€ã³ã¿ãŒãã§ã€ã¹ã¯æ倧 4 ã€ã«å¶é)
Advanced Edge ãŸã㯠Core ã©ã€ã»ã³ã¹ããµããŒããããã¹ãŠã®ãã©ãããã©ãŒã
PIM-SM-Edge (ã¢ã¯ãã£ããªã€ã³ã¿ãŒãã§ã€ã¹ã¯æ倧 4 ã€ã«å¶é)
Advanced Edge ãŸã㯠Core ã©ã€ã»ã³ã¹ããµããŒããããã¹ãŠã®ãã©ãããã©ãŒã
VRRP
Advanced Edge ãŸã㯠Core ã©ã€ã»ã³ã¹ããµããŒããããã¹ãŠã®ãã©ãããã©ãŒã
VXLAN
Summit X770ãX670-G2ãããã³ ExtremeSwitching X870ãX690ã
OVSDB
Summit X770ãX670-G2ãããã³ ExtremeSwitching X870ãX690ã
PSã¿ã°
Summit X460-G2ãX670-G2ãX770ãããã³ ExtremeSwitching X870ãX690 ã·ãªãŒãº ã¹ã€ããã
ã³ã¢ã©ã€ã»ã³ã¹
ExtremeXOS ãœãããŠã§ã¢ã®æ©èœ
ãµããŒããããŠãããã©ââãããã©ãŒã
PIM DMããã«ã
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
PIM SMããã«ã
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
PIM SSMããã«ã
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
OSPFv2ããã«ãïŒã¢ã¯ãã£ããªã€ã³ã¿ãŒãã§ã€ã¹ã 4 ã€ã«éå®ãããªãïŒ
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
OSPFv3ããã«ãïŒã¢ã¯ãã£ããªã€ã³ã¿ãŒãã§ã€ã¹ã 4 ã€ã«éå®ãããªãïŒ
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
IPv4 ECMP ã® BGP4 ããã³ MBGP (BGP4+)
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
IPv4 ã® BGP4 ããã³ MBGP (BGP6+)
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
IPv4 ã® IS-IS
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
IPv6 ã® IS-IS
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
MSDP
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
ãšããŒãã£ã¹ã RP
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
GREãã³ããªã³ã°
ã³ã¢ã©ã€ã»ã³ã¹ãã©ãããã©ãŒã
MPLS æ©èœãã¢ã¯ãã£ãåããã«ã¯ãåå¥ã®æ©èœããã¯ããããŸããããã«ã€ããŠã¯åŸã§èª¬æããŸãã
X440-G2ã·ãªãŒãº
EXOS ã¹ã€ããã®ã¬ãã¥ãŒããã®ã·ãªãŒãºã®ã¹ã€ããããå§ããããšããå§ãããŸãããã®ã·ãªãŒãºã®ã¹ã€ããã¯ãExtremeNetworks ã«ãã£ãŠç©æ¥µçã«ãµããŒããããŠãããæé·ã«å¿ããŠæ¯æããã³ã³ã»ãããæ確ã«èª¬æããŠããŸãã
ãã®ã³ã³ã»ããã®äž»ãªèãæ¹ã¯ãæ©åšèªäœããã®éšåã亀æããããšãªããè³Œå ¥ããŠèšçœ®ããæ©åšã®çç£æ§ãšæ©èœãåŸã ã«åäžãããããšã§ãã
ããããããããããã«ã次ã®äŸã瀺ããŸãã
- æåã«ãé ç·ãŸãã¯å ã¢ã¯ã»ã¹ ããŒããåãã 24 ããŒããŸã㯠48 ããŒãã®ã¹ã€ãããå¿ èŠã§ãããšããŸãããã®ã¹ã€ããã§ã¯ãæåã¯ã¢ã¯ã»ã¹ ããŒãã® 50% (12 åãŸã㯠24 å) ãå æããããã©ã³ã¯ ããŒãã®åèšãã©ãã£ãã¯ãããããã®ã¹ã€ããã«å²ãåœãŠãããŸããæ¹å (éåžžãããã¯åäœäžã®ãã·ã³ã®ããŠã³ãªã³ã¯) ã¯æ倧 1 Gbit/s ã«ãªããŸãã
- æåã« X440-G2-24t-10GE4 ãŸã㯠X440-G2-48t-10GE4 ã¹ã€ãããéžæãããšããŸãããããã®ã¹ã€ããã«ã¯ã24 ãŸã㯠48 ã® 1000 BASE-T ã¢ã¯ã»ã¹ ããŒããš 4 ã€ã®ã®ã¬ããã ã€ãŒãµããã SFP/SFP+ ããŒããããã10 ã®ã¬ããã ã€ãŒãµããããŸã§æ¡åŒµã§ããŸãã
- ã¹ã€ãããæ§æããŠèšçœ®ããã³ã¢ãŸãã¯ã¢ã°ãªã²ãŒã·ã§ã³ (ãããã¯ãŒã¯ã®æ§é ã«å¿ããŠ) ã« 1 ã€ã®ãã©ã³ã¯ ããŒããå«ãããŠãŒã¶ãŒãã¹ã€ããã«æ¥ç¶ããŸããããã¹ãŠãæ©èœããããªããšç®¡çè ã¯æºè¶³ããŠããŸãã
- æéã®çµéãšãšãã«ããã£ã³ããŒã³ãšãããã¯ãŒã¯ãæ¡å€§ããŸã - æ°ãããŠãŒã¶ãŒããµãŒãã¹ãæ©åšãç»å ŽããŸã
- ãã®çµæãæ€èšäžã®ã¹ã€ãããå«ãããããã¯ãŒã¯ã®ããŸããŸãªã¬ãã«ã§ãã©ãã£ãã¯ãå¢å ããå¯èœæ§ããããŸãã ããã¯ããŸããŸãªçç±ã§çºçããå¯èœæ§ããããŸããæ°ããããã€ã¹ãã¹ã€ããã«æ¥ç¶ãããããŠãŒã¶ãŒãããŸããŸãªãµãŒãã¹ããã®ãã©ãã£ãã¯ããŸããŸãæ¶è²»ãå§ããããéåžžã¯äž¡æ¹ãåæã«çºçããŸãã
- æéãçµã€ãšãã¹ã€ããã®ãã©ã³ã¯ ããŒãã®è² è·ã 1 Gbps ã«éããŠããããšãããããŸãã
- ã¹ã€ãããšã¢ã°ãªã²ãŒã·ã§ã³ (ã³ã¢) ã®éã®éä¿¡ãªã³ã¯ãéçŽããããã«äœ¿çšã§ããã®ã¬ããã ã€ãŒãµããã ããŒããããã« 3 ã€ããã®ã§ãåé¡ã¯ãªããšæããŸããããšãã°ã次ã®ããã«ããŠããããã®éã«å¥ã®å ãªã³ã¯ãŸãã¯é ç·ãªã³ã¯ã確ç«ããã¢ã°ãªã²ãŒã·ã§ã³ãèšå®ããŸãããããã³ã«LACP
- æéãçµã€ãšãXNUMX ã€ä»¥äžã®ã¹ã€ãããèšçœ®ããå¿ èŠãçããŸãã
- ç¶æ³ã«ãã£ãŠã¯ãæ¢åã® X440 ã¹ã€ãããä»ããŠæ°ããã¹ã€ãããæå¹ã«ããå¿
èŠãçããå¯èœæ§ããããŸãã
- æå¹ã«ããã¢ã°ãªã²ãŒã·ã§ã³ãŸãã¯ã³ã¢ ããŒããäžè¶³ããŠããŸãããã®å Žåãè¿œå ã®ã¢ã°ãªã²ãŒã·ã§ã³ ã¹ã€ãããŸãã¯ã³ã¢ ã¬ãã«ã®ã¹ã€ãããè³Œå ¥ããå¿ èŠããããŸãã
- ã¹ã€ãããã¢ã°ãªã²ãŒã·ã§ã³ ããŒãããé¢ããŠããããå ãã¡ã€ããŒãªã©ã®æ¢åã®ã±ãŒãã« ã«ãŒãã®å®¹éãäžè¶³ããŠããå Žåã¯ãæ°ããéä¿¡åç·ã®å»ºèšãšå€§å¹ ãªè¿œå ã³ã¹ããå¿ èŠã«ãªããŸãã
- ææªã®ã·ããªãªã§ã¯ãXNUMX ã€ã®ãªãã·ã§ã³ãåæã«çºçããå¯èœæ§ããããŸã
- 管çè
ãšãšãã«ãããã¯ãŒã¯èšèšãšè¿œå ã³ã¹ããæ€èšããåŸãæ¢åã® X440 ã¹ã€ãããä»ããŠæ°ãã XXNUMX ã¹ã€ããããããã¯ãŒã¯ã«æ¥ç¶ããããšã«ããŸãã åé¡ãããŸãããããã«ã¯ããã€ãã®ãªãã·ã§ã³ããããŸãã
- ãªãã·ã§ã³ 1 - ã¹ã¿ããã³ã°:
- SummitStack-V ãã¯ãããžãŒã䜿çšããŠãæåã® X2 ã¹ã€ããã®æ®ãã® 2 ã€ã®ãã©ã³ã¯ ããŒããš 440 çªç®ã® X2 ã¹ã€ããã® 440 ã€ã®ãã©ã³ã¯ ããŒãã䜿çšããŠãXNUMX ã€ã®ã¹ã€ãããã¹ã¿ãã¯ã§ããŸãã
- è·é¢ã«å¿ããŠãæé·æ°åããã¡ãŒãã«ãŸã§ãçã DAC ã±ãŒãã«ãš SFP+ ãã©ã³ã·ãŒããŒã®äž¡æ¹ã䜿çšã§ããŸãã
- ãããã£ãŠãã¹ã€ããã®ã¹ã¿ããã³ã°ã¯ã2 ã€ã®ãã©ã³ã¯ ããŒãïŒé垞㯠4 ããŒã ã¢ãã«ã§ã¯ããŒã 27ã28ã24 ããŒã ã¢ãã«ã§ã¯ããŒã 49ã50ïŒããã¹ã¿ããã³ã°çšã«å²ãåœãŠããã 48 ã€ã®ããŒããä»ããŠè¡ãããŸãã åããŒãã®ã¹ã¿ããã³ã° ããŒãã®åž¯åå¹ ã¯ 20 Gb (äžæ¹åã« 10 Gbãããäžæ¹ã®æ¹åã« 10 Gb) ã«ãªããŸãã
- ãã®å Žåããã©ã³ã¯ ããŒãã 1 GE ãã 10 GE ã«æ¡åŒµããããã®ã©ã€ã»ã³ã¹ã¯å¿ èŠãããŸããã
- ãªãã·ã§ã³ 2 - ãã©ã³ã¯ ããŒãã䜿çšããããã«éçŽããå¯èœæ§ããããŸãã
- æåã® X1 ã®æ®ãã®ãã©ã³ã¯ ããŒã 2 ã€ãŸã㯠440 ã€ïŒéçŽã®å ŽåïŒãšãæ°ãã X1 ã®ãã©ã³ã¯ ããŒã 2 ã€ãŸã㯠440 ã€ã䜿çšããŠãXNUMX çªç®ã®ã¹ã€ãããæå¹ã«ã§ããŸãã
- ããã§ã¯ããã©ã³ã¯ ããŒãã 1 GE ãã 10 GE ã«æ¡åŒµããããã®ã©ã€ã»ã³ã¹ãå¿ èŠãããŸããã
- ãªãã·ã§ã³ 1 - ã¹ã¿ããã³ã°:
- èšç»ã©ãããæåã® X440 ã¹ã€ãããã XNUMX ã€ä»¥äžã®ã¹ã€ãããçŽåãŸãã¯ã¹ã¿ãŒæ¥ç¶ããŸããã
- æéãçµã¡ãæåã® X440 ã¹ã€ããã®ãã©ã³ã¯ ããŒãã®ãã©ãã£ãã¯ã 2 Gbps ã«éããããšã«æ°ä»ãã次ã®æäœãè¡ãå¿
èŠããããŸãã
- ã¢ã°ãªã²ãŒã·ã§ã³ãšæåã® X440 ã¹ã€ããã®éã«ãªã³ã¯ ã¢ã°ãªã²ãŒã·ã§ã³çšã®ããŒãã 440 ã€ä»¥äžå¿ èŠã«ãªããããäžã§èª¬æããæ°ãã XXNUMX ã¹ã€ãããèšçœ®ãããšããšåãåé¡ãã€ãŸãã¢ã°ãªã²ãŒã·ã§ã³æ©åšã®ããŒãã®äžè¶³ããŸãã¯ã±ãŒãã«é ç·ã€ã³ãã©ã¹ãã©ã¯ãã£ã®å®¹éã®äžè¶³ãçºçããå¯èœæ§ããããŸãã
- ãŸãã¯ãã¢ã°ãªã²ãŒã·ã§ã³æ©åšãšæåã® X10 ã¹ã€ããã®éã®ãã©ã³ã¯ 440 ã®ã¬ãããã€ãŒãµããã ããŒãã䜿çšããŸãã
- ãã®æç¹ã§ãé©åãªã©ã€ã»ã³ã¹ã䜿çšããŠãã©ã³ã¯ ããŒãã®åž¯åå¹
ã 440 ã®ã¬ããã ã€ãŒãµããããã 1 ã®ã¬ããã ã€ãŒãµãããã«æ¡åŒµã§ãã X10 ã¹ã€ããã®æ©èœã圹ã«ç«ã¡ãŸãã 決å®ãããªãã·ã§ã³ã«å¿ããŠã次ã®ããã«ãªããŸãã
- ãªãã·ã§ã³ 1 (ã¹ã¿ããã³ã°) ã®å Žå - ãã¥ã¢ã« 10GbE ã¢ããã°ã¬ãŒã ã©ã€ã»ã³ã¹ã䜿çšããŸãã æåã® X440 ã§ã©ã€ã»ã³ã¹ãã¢ã¯ãã£ãåãããšããã®ãã©ã³ã¯ ããŒãã®ãã¡ 2 ã€ã®ã¹ã«ãŒãããã 1 ã®ã¬ããã ã€ãŒãµããããã 10 ã®ã¬ããã ã€ãŒãµãããã«æ¡åŒµãããŸã (èŠããŠãããšãããæ®ãã® 2 ã€ã®ããŒãã¯ã¹ã¿ããã³ã°ã«äœ¿çšãããŸã)ã
- ãªãã·ã§ã³ 2 (ãã©ã³ã¯ ããŒã) ã®å Žå - æåã® X10 ãš 10 çªç®ã® X440 ã®éã®ãã©ã³ã¯ ããŒãã®è² è·ã«å¿ããŠããã¥ã¢ã« 440GbE ã¢ããã°ã¬ãŒã ã©ã€ã»ã³ã¹ãŸãã¯ã¯ã¢ãã XNUMXGbE ã¢ããã°ã¬ãŒã ã©ã€ã»ã³ã¹ã䜿çšããŸãã ããã«ã¯ããã€ãã®ãªãã·ã§ã³ãããå ŽåããããŸãã
- ãŸããæåã® X10 ã§ãã¥ã¢ã« 440GbE ã©ã€ã»ã³ã¹ãã¢ã¯ãã£ãåã§ããŸãã
- 次ã«ã440 ã€ä»¥äžã®ã¹ã€ãããçŽåã«æ¥ç¶ãããŠããããã« 10 çªç®ã® X440 ã®ãã©ãã£ãã¯ãå¢å ãããããæåã® X10 ã§å¥ã®ãã¥ã¢ã« 440GbE ã©ã€ã»ã³ã¹ãã¢ã¯ãã£ãåããXNUMX çªç®ã® XXNUMX ã¹ã€ããã§ãã¥ã¢ã« XNUMXGbE ã©ã€ã»ã³ã¹ãã¢ã¯ãã£ãã«ããŸãã
- ã¹ã€ããã®åå²ã«æ²¿ã£ãŠé 次ç¶ããŸã
- ããã«æéãçµã€ãšãçµç¹ã¯æ°Žå¹³æ¹å (ãããã¯ãŒã¯ ããŒãã®æ°ãå¢å ) ãšåçŽæ¹åã®äž¡æ¹ã§æé·ãç¶ãããããã¯ãŒã¯æ§é ã¯ããè€éã«ãªããç¹å®ã®ãããã³ã«ã®åäœãå¿ èŠãšããæ°ãããµãŒãã¹ãç»å ŽããŸãã
- çµç¹ã®ããŒãºã«å¿ããŠãã¹ã€ããã® L2 ãã L3 ã«ç§»è¡ããããšã決å®ããå ŽåããããŸãã ããªãã®æ±ºå®ã«åœ±é¿ãäžããå¯èœæ§ã®ããããŒãºã¯å€§ããç°ãªãå ŽåããããŸãã
- ãããã¯ãŒã¯ã»ãã¥ãªãã£èŠä»¶
- ãããã¯ãŒã¯ã®æé©å (OSPF ãªã©ã®åçã«ãŒãã£ã³ã° ãããã³ã«ã®å°å ¥ã䌎ããããŒããã£ã¹ã ãã¡ã€ã³ã®åæžãªã©)
- ç¹å®ã®ãããã³ã«ãå¿ èŠãšããæ°ãããµãŒãã¹ã®å®è£
- ãã®ä»ã®çç±
- åé¡ãªãã X440 ã¹ã€ããã¯ãæ©èœãæ¡åŒµããã©ã€ã»ã³ã¹ (ã¢ããã³ã¹ã ãœãããŠã§ã¢ ã©ã€ã»ã³ã¹) ãè¿œå è³Œå ¥ããŠã¢ã¯ãã£ããŒãã§ãããããåŒãç¶ãé¢é£ããŸãã
ããã§èª¬æããäŸãããããããã«ãX440 ã¹ã€ãã (ããã³ä»ã®ã»ãšãã©ã®ã¹ã€ãã ã·ãªãŒãº) ã¯ãæé·ã«å¿ããŠæ¯æããååã«æºæ ããŠããŸãã çµç¹ããããã¯ãŒã¯ã®æé·ã«å¿ããŠã¹ã€ããæ©èœãè¿œå ããã«ã¯æéãæ¯æããŸãã
ãã®ç¹ã«é¢ããŠãç§ã¯æè©ãé¢ããŠãã¹ã€ããã®èå¯ã«è¿ã¥ãããšãææ¡ããŸãã
以äžã®è¡šãèŠãã°ãããããã«ãX440 ã·ãªãŒãºã«ã¯å€ãã®æ§æãªãã·ã§ã³ãããããšã«æ³šæããŠãã ããã
* X440-G2 ã·ãªãŒãº ã¹ã€ããã¯ãSummitStack-V ãšä»ã®ã¹ã€ãã ã·ãªãŒãº (X450-G2ãX460-G2ãX670-G2ãX770) ãšã®ã¹ã¿ããã³ã°ããµããŒãããŸãã ã¹ã¿ããã³ã°ãæåãããäž»ãªæ¡ä»¶ã¯ãã¹ã¿ãã¯ã®ã¹ã€ããã§åãããŒãžã§ã³ã® EXOS ã䜿çšããããšã§ãã
** è¡šã®åºæ¬æ©èœã¯ãã·ãªãŒãº ã¹ã€ããã®æ©èœã®äžéšã®ã¿ã瀺ããŠããŸãã ãµããŒããããŠãããããã³ã«ãšæšæºã®ãã詳ãã説æã¯ããšããž ã©ã€ã»ã³ã¹ã®è¡šã«ãããŸãã
ãã®ã·ãªãŒãºã®ã¹ã€ããã«ã¯è¿œå å ¥åãã€ãŸãé»å§ã³ã³ããŒã¿ãä»ã㊠RPS é»æºãŸãã¯å€éšããããªãæ¥ç¶ããããã®åé·é»æºå ¥åãè£ åãããŠããŸãã
X440-G2 ã·ãªãŒãº ã¹ã€ããã§ã¯æ¬¡ã®ã©ã€ã»ã³ã¹ãå©çšå¯èœã§ãã
以äžã¯ãX440 ã·ãªãŒãº ã¹ã€ããã瀺ãããã€ãã®åçã§ãã
X450-G2ã·ãªãŒãº
ExtremeNetworks ã¯ãSummit X450-G2 ã·ãªãŒãºããã£ã³ãã¹åãã®å¹ççãªãšããž ã¹ã€ãããšããŠäœçœ®ä»ããŠããŸãã
X450-G2 ã¹ã€ãããš X440-G2 ã·ãªãŒãºã®äž»ãªéãã¯æ¬¡ã®ãšããã§ãã
- æ¡åŒµã©ã€ã»ã³ã¹ ã»ãã (å¯èœãªæ©èœ) - ãšããž ã©ã€ã»ã³ã¹ãã¢ããã³ã¹ã ãšããž ã©ã€ã»ã³ã¹ãã³ã¢ ã©ã€ã»ã³ã¹
- ã¹ã€ããã®èé¢ã«ããŒã«ããã¹ã¿ããã³ã°çšã®åå¥ã® QSFP ããŒãã®ååš
- PoE ãµããŒããåããã¢ãã«ã«è¿œå ã®é»æºãè£ åããæ©èœ
- æšæºãµããŒã
- 10GE SFP+ ããŒããåããã¹ã€ããã§ã¯ãããŒã垯åå¹ ã 1 GB ãã 10 GB ã«æ¡åŒµããããã«å¥åã®ã©ã€ã»ã³ã¹ãè¿œå è³Œå ¥ããå¿ èŠã¯ãããŸããã
*SummitStack-V84 ã¹ã¿ããã³ã°ã¯ X450-G2 ã·ãªãŒãºã§ã®ã¿ãµããŒããããŸãã
**X440-G2 ã·ãªãŒãº ã¹ã€ããã¯ãä»ã®ã¹ã€ãã ã·ãªãŒãº (X440-G2ãX460-G2ãX670-G2ãããã³ X770) ãšã® SummitStack-V ã®ã¹ã¿ããã³ã°ããµããŒãããŸãã ã¹ã¿ããã³ã°ãæåãããäž»ãªæ¡ä»¶ã¯ãã¹ã¿ãã¯ã®ã¹ã€ããã§åãããŒãžã§ã³ã® EXOS ã䜿çšããããšã§ãã
*** è¡šã®åºæ¬æ©èœã¯ãã·ãªãŒãº ã¹ã€ããã®æ©èœã®äžéšã®ã¿ã瀺ããŠããŸãã ãµããŒããããŠãããããã³ã«ãšæšæºã®ãã詳ãã説æã¯ããšããž ã©ã€ã»ã³ã¹ã®è¡šã«ãããŸãã
PoE ã®ãªããã®ã·ãªãŒãºã®ã¹ã€ããã«ã¯ãé»å§ã³ã³ããŒã¿ãä»ã㊠RPS é»æºãŸãã¯å€éšããããªãæ¥ç¶ããããã®åé·é»æºå ¥åãšããè¿œå ã®å ¥åãè£ åãããŠããŸãã
ãã®ã·ãªãŒãºã®ã¹ã€ããã¯ãã¡ã³ ã¢ãžã¥ãŒã«ãªãã§æäŸãããŸãã å¥é泚æããå¿ èŠããããŸãã
X450-G2 ã·ãªãŒãº ã¹ã€ããã§ã¯æ¬¡ã®ã©ã€ã»ã³ã¹ãå©çšå¯èœã§ãã
X450-G2 ã·ãªãŒãº ã¹ã€ããã®ã€ã¡ãŒãžã以äžã«ç€ºããŸãã
X460-G2ã·ãªãŒãº
X460-G2 ã·ãªãŒãº ã¹ã€ããã¯ãQSFP+ ããŒãã䜿çšã§ããæãè¥ãã·ãªãŒãºã®ã¹ã€ããã§ãã ãã®ã·ãªãŒãºã®ç¹åŸŽã¯æ¬¡ã®ãšããã§ãã
- ããŸããŸãªããŒãã®æè»ãªã»ãããåããå€æ°ã®ã¢ãã«ã®ååš
- è¿œå ã® VIM ã¢ãžã¥ãŒã«ãããŒã (SFP+ãQSFP+ãã¹ã¿ããã³ã° ããŒã) ã§äœ¿çšããããã®åå¥ã® VIM ã¹ãããã®ååš
- 2.5GBASE-T (802.3bz) èŠæ Œã®äžéšã®ã¢ãã«ã§ã®ãµããŒã
- MPLSã®ãµããŒã
- åæã€ãŒãµãããèŠæ ŒãšTM-CLKã¢ãžã¥ãŒã«ã®ãµããŒã
- ãã¹ãŠã®ã¹ã€ãã ã¢ãã«ã«è¿œå ã®é»æºãè£ åã§ããæ©èœ
ãã®ã·ãªãŒãºã®ã¹ã€ããã®ããŒããŠã§ã¢æ§æãªãã·ã§ã³ã¯ã次ã®è¡šãã確èªã§ããŸãã
* ãã®ã·ãªãŒãºã®ã¹ã€ããã«ã¯ãé»æºããã¡ã³ ã¢ãžã¥ãŒã«ãVIM ã¢ãžã¥ãŒã«ã¯ä»å±ããŸããã å¥é泚æããå¿
èŠããããŸãã
** X440ãX460ãX460-G2ãããã³ X480 ã·ãªãŒãºãšäºææ§ãããããã¹ãŠã®ã¹ã€ããã®ãœãããŠã§ã¢ ããŒãžã§ã³ãåãã§ããå¿
èŠããããŸã
*** X440ãX440-G2ãX450ãX450-G2ãX460ãX460-G2ãX480ãX670ãX670VãX670-G2ãããã³ X770 ã·ãªãŒãºãšäºææ§ãããããã¹ãŠã®ã¹ã€ããã®ãœãããŠã§ã¢ ããŒãžã§ã³ãåãã§ããå¿
èŠããããŸã
**** X460-G2ãX480ãX670VãX670-G2ãããã³ X770 ã·ãªãŒãºãšäºææ§ãããããã¹ãŠã®ã¹ã€ããã®ãœãããŠã§ã¢ ããŒãžã§ã³ãåãã§ããå¿
èŠããããŸã
ãã¡ã³ã¢ãžã¥ãŒã«ã¯ããã³ãããŒããã¯ãšããã¯ããŒããã³ãã®2çš®é¡ãçšæãããŠããããµãŒããŒã«ãŒã ã®ãããã¢ã€ã«ãšã³ãŒã«ãã¢ã€ã«ã®é 眮èŠä»¶ã«åãããŠå·åŽã¢ãã«ãéžæã§ããŸãã
ããŒãæ¡åŒµçšã® VIM ã¢ãžã¥ãŒã«ãš X460-G2 ã·ãªãŒãº ã¹ã€ããã§å©çšå¯èœãªã©ã€ã»ã³ã¹ã¯ã次ã®è¡šããéžæã§ããŸãã
ãã®ã·ãªãŒãºã®ã¬ãã¥ãŒã®æåŸã«ãã¹ã€ããã®ç»åãããã€ã玹ä»ããŸãã
X620-G2ã·ãªãŒãº
X620-G2 ã·ãªãŒãº ã¹ã€ããã¯ãåºå®ããŒã ã»ãããåããã³ã³ãã¯ã㪠10 GE ã¹ã€ããã§ãã Edge ã©ã€ã»ã³ã¹ãš Advanced Edge ã©ã€ã»ã³ã¹ã® 2 çš®é¡ã®ã©ã€ã»ã³ã¹ã§æ³šæã§ããŸãã
440x2 GE SFP+ ãã¥ã¢ã«ããŒãã¹ ããŒã¿/ã¹ã¿ããã³ã° ããŒãçµç±ã§ãSummitStack-V ãã¯ãããžãŒã䜿çšããã¹ã€ãã ã·ãªãŒãº (X450-G2ãX460-G2ãX670-G2ãX770-G2ãããã³ X10) ãšã®ã¹ã¿ããã³ã°ããµããŒãããŸãã
PoE+ ããŒããåããã¢ãã«ã¯ã60W 802.3bt 4 ã㢠PoE++ - ã¿ã€ã 3 PSE ããµããŒãããŸãã ãã¹ãŠã®ã¢ãã«ã¯ãè¿œå ã®é»æºè£ 眮ãåãä»ããæ©èœããµããŒãããŠããŸãã
以äžã®è¡šã¯ããã®ã·ãªãŒãºã§å¯èœãªããŒããŠã§ã¢æ§æã瀺ããŠããŸãã
ã¹ã€ãããšäžç·ã«æ³šæããã«ã¯ãããã€ãã®ã¿ã€ãã®ã©ã€ã»ã³ã¹ã䜿çšã§ããŸãã
åèãŸã§ã«ã¹ã€ããã®ç»åãããã€ãæ·»ä»ããŸãã
X670-G2ã·ãªãŒãº
X670-G2 ã·ãªãŒãº ã¹ã€ããã¯ãããŒãå¯åºŠãé«ãé«æ§èœ 1RU ã¢ã°ãªã²ãŒã·ã§ã³ãŸãã¯ã³ã¢ ã¹ã€ããã§ãããV400 ã¹ã€ããã®ã³ã³ãããŒã© ããªããžãšããŠãæ©èœããŸãã 48 åããã³ 72 åã®åºå® 10 GE SFP+ ããŒããš 4 åã® QSFP+ ããŒããåããã¹ã€ããã泚æã§ããŸãã
ãããã®ã¹ã€ããã«ã¯ãAdvanced Edge License (åæã©ã€ã»ã³ã¹ãšããŠ) ãš Core License ã® 2 çš®é¡ã®ã©ã€ã»ã³ã¹ãä»å±ããŠãããSummitStack-VãSummit-Stack-4ãSummitStack-80ãSummitStack-160 ã® 320 ã€ã®ç°ãªãã¹ã¿ããã³ã°æ¹æ³ããµããŒãããŠããŸãã
倧èŠæš¡ãªã€ã³ã¿ãŒããã ãããã€ããŒãéåžžã«å€§èŠæš¡ãªäŒæ¥ã«ãšã£ãŠãMPLS ãã£ãŒãã£ãŒ ããã¯ã¯èå³æ·±ããã®ã«ãªããŸããããã«ãããæ©èœãæ¡åŒµããã¹ã€ããã LSR ãŸã㯠LER ã³ã¢ ã«ãŒã¿ãŒãšããŠäœ¿çšããL2VPN (VPLS) ããµããŒããããã«ããµãŒãã¹ ãããã¯ãŒã¯ãæ§ç¯ããããšãã§ããŸãã /VPWS)ãBGP ããŒã¹ã® L3VPNS ãLDP ãããã³ã«ã«åºã¥ã LSPãRSVP-TEãéçããããžã§ãã³ã°ãVCCVãBFDãCFM ãªã©ã®ããŸããŸãªããŒã«ã
ã¹ã€ãã㯠2 ã€ã®æ§æã§æ³šæã§ããŸãã
*ã·ãªãŒãºãšã®ã¹ã¿ããã³ã°äºææ§ - X440ãX440-G2ãX450ãX450-G2ãX460ãX460-G2ãX480ãX670ãX670VãX770
ã¹ã€ããã¯ãã¡ã³ ã¢ãžã¥ãŒã«ãšé»æºãªãã§æäŸãããŸãããããã¯åå¥ã«æ³šæããå¿ èŠããããŸãã éžã¶éã®åºæ¬æ¡ä»¶ã¯ä»¥äžã®éãã§ãã
- ãã¡ã³ ã¢ãžã¥ãŒã«ã®å®å šãªã»ãã (5 å) ãåãä»ããå¿ èŠããããŸãã
- é»æºãšãã¡ã³ ã¢ãžã¥ãŒã«ã¯ãåãæ¹åã®ç©ºæ°ã®æµããç¶æã§ãããµã€ãºã«ããå¿ èŠããããŸãã
ãã®ã·ãªãŒãºã®ã¹ã€ãããšäžç·ã«æ¬¡ã®ã©ã€ã»ã³ã¹ã泚æã§ããŸãã
ãã®ã·ãªãŒãºã®ã¬ãã¥ãŒã®æåŸã«ãã¹ã€ããã® 2 ã€ã®ç»åã瀺ããŸãã
ã·ãªãŒãº X590
ã·ãªãŒãº ã¹ã€ããã«ã¯ 1GE/10GE/25GE/40GE/50GE/100GE ããŒããçµã¿èŸŒãŸããŠããã次ã®ããã«äœ¿çšã§ããããã«èšèšãããŠããŸãã
- ã³ã¢ãŸãã¯ã¢ã°ãªã²ãŒã·ã§ã³ ã¹ã€ãã
- V400 ã¢ã¯ã»ã¹ ã¹ã€ãããšçµã¿åãããã³ã³ãããŒã© ããªããž ã¹ã€ãã
- ããããªãã©ã㯠ããŒã¿ã»ã³ã¿ãŒ ã¹ã€ãã
ã¹ã€ãã㯠2 ã€ã®ã¿ã€ãã§æäŸãããŸã - SFP ããŒããš BASE-T ããŒããåãã2 ã€ã®é»æºãåããŠããŸãã
â»X690ãX870ã·ãªãŒãºãšäºææ§ããããŸãã
ã¹ã€ããã¯ãã¡ã³ ã¢ãžã¥ãŒã«ãšé»æºãªãã§æäŸãããŸãããããã¯åå¥ã«æ³šæããå¿ èŠããããŸãã éžå®ã®äž»ãªæ¡ä»¶ã¯ä»¥äžã®éãã§ãã
- ãã¡ã³ ã¢ãžã¥ãŒã«ã®å®å šãªã»ãã (4 å) ãåãä»ããå¿ èŠããããŸãã
- é»æºãšãã¡ã³ ã¢ãžã¥ãŒã«ã¯ãåãæ¹åã®ç©ºæ°ã®æµããç¶æã§ãããµã€ãºã«ããå¿ èŠããããŸãã
- AC é»æºãš DC é»æºãåæã«ã¹ã€ããã«åãä»ããããšã¯ã§ããŸãã
ãããã®ã¹ã€ããã§æ³šæã§ããã©ã€ã»ã³ã¹ã¯æ¬¡ã®ãšããã§ãã
ã¹ã€ããã®ã€ã¡ãŒãžã次ã®å³ã«ç€ºããŸãã
ã·ãªãŒãº X690
ã·ãªãŒãº ã¹ã€ããã«ã¯ãX1 ã·ãªãŒãºãšæ¯èŒããŠãããå€ãã® 10GE/25GE/40GE/50GE/100GE/590GE ããŒããå èµãããŠããã次ã®çšéã«ã䜿çšã§ããããã«èšèšãããŠããŸãã
- ã³ã¢ãŸãã¯ã¢ã°ãªã²ãŒã·ã§ã³ ã¹ã€ãã
- V400 ã¢ã¯ã»ã¹ ã¹ã€ãããšçµã¿åãããã³ã³ãããŒã© ããªããž ã¹ã€ãã
- ããããªãã©ã㯠ããŒã¿ã»ã³ã¿ãŒ ã¹ã€ãã
ã·ãªãŒãº ã¹ã€ããã«ã¯ãSFP ããŒããš BASE-T ããŒããããã³ 2 ã€ã®é»æºã®ãªãã·ã§ã³ãåãã 2 ã€ã®ã¿ã€ãããããŸãã
â»X590ãX870ã·ãªãŒãºãšäºææ§ããããŸãã
ã¹ã€ããã¯ãã¡ã³ ã¢ãžã¥ãŒã«ãšé»æºãªãã§æäŸãããŸãããããã¯åå¥ã«æ³šæããå¿
èŠããããŸãã éžå®ã®äž»ãªæ¡ä»¶ã¯ä»¥äžã®éãã§ãã
- ãã¡ã³ ã¢ãžã¥ãŒã«ã®å®å šãªã»ãããåãä»ããå¿ èŠããããŸã - 6 å
- é»æºãšãã¡ã³ ã¢ãžã¥ãŒã«ã¯ãåãæ¹åã®ç©ºæ°ã®æµããç¶æã§ãããµã€ãºã«ããå¿ èŠããããŸãã
- AC é»æºãš DC é»æºãåæã«ã¹ã€ããã«åãä»ããããšã¯ã§ããŸãã
ãããã®ã¹ã€ããã§æ³šæã§ããã©ã€ã»ã³ã¹ã¯æ¬¡ã®ãšããã§ãã
ã¹ã€ããã®ã€ã¡ãŒãžã次ã®å³ã«ç€ºããŸãã
ã·ãªãŒãº X870
X870 ãã¡ããªã¯é«å¯åºŠ 100Gb ã¹ã€ããã§ãé«æ§èœãšã³ã¿ãŒãã©ã€ãº ã³ã¢ ã¹ã€ããããã³ã¹ãã€ã³/ãªãŒã ããŒã¿ã»ã³ã¿ãŒ ã¹ã€ãããšããŠäœ¿çšã§ããŸãã
äœé
延ã¹ã€ããã³ã°ãšé«åºŠãªã³ã¢ããã³ MPLS ã©ã€ã»ã³ã¹æ©èœã«ãããé«æ§èœããŒã¿ã»ã³ã¿ãŒ ã¢ããªã±ãŒã·ã§ã³ã§ã®äœ¿çšã«æé©ã§ãã
x870-96x-8c-Base ã¹ã€ããã¯ããæé·ã«å¿ããŠæ¡åŒµãããã€ããªãã®ãŒãå®è£
ããŠããŸããããã¯ãã¢ããã°ã¬ãŒã ã©ã€ã»ã³ã¹ã䜿çšããŠããŒãã®ã¹ã«ãŒããããæ¡åŒµã§ããæ©èœã«ãããŸã (ã©ã€ã»ã³ã¹ã¯ãæ倧 6 ã€ã®ããŒãã®ã°ã«ãŒãã«é©çšãããŸã)ã 4ã©ã€ã»ã³ã¹ïŒã
ã¹ã€ãã㯠2 ã€ã®æ§æã§æäŸããã2 ã€ã®é»æºãè£ åãããŠããŸãã
â»X590ãX690ã·ãªãŒãºãšäºææ§ããããŸãã
ã¹ã€ããã¯ãã¡ã³ ã¢ãžã¥ãŒã«ãšé»æºãªãã§æäŸãããŸãããããã¯åå¥ã«æ³šæããå¿
èŠããããŸãã éžå®ã®äž»ãªæ¡ä»¶ã¯ä»¥äžã®éãã§ãã
- ãã¡ã³ ã¢ãžã¥ãŒã«ã®å®å šãªã»ãããåãä»ããå¿ èŠããããŸã - 6 å
- é»æºãšãã¡ã³ ã¢ãžã¥ãŒã«ã¯ãåãæ¹åã®ç©ºæ°ã®æµããç¶æã§ãããµã€ãºã«ããå¿ èŠããããŸãã
- AC é»æºãš DC é»æºãåæã«ã¹ã€ããã«åãä»ããããšã¯ã§ããŸãã
ãããã®ã¹ã€ãããšäžç·ã«è³Œå ¥ã§ããã©ã€ã»ã³ã¹ã¯æ¬¡ã®ãšããã§ãã
以äžã®å³ã«ç€ºãããã«ã2 ã€ã®ã¿ã€ãã®ã¹ã€ããã¯ãŸã£ããåãã«èŠããŸãã
ãŸãšã
çããããã®ã¬ãã¥ãŒèšäºããã®ã·ãªãŒãºã§çµäºããããšæããŸããããã¯ãå 容ã巚倧ãªã¬ãã«ã«ãŸã§èšããŸããŠããã®èªã¿ãšèªèãè€éã«ããªãããã«ããããã§ãã
ExtremeNetworks ã«ã¯ããã«å€ãã®çš®é¡ã®ã¹ã€ããããããšèšããããåŸãŸããã
- ããã㯠VSP (ä»®æ³ãµãŒãã¹ ãã©ãããã©ãŒã ) ã¢ãã«ã§ããããã®äžéšã¯ç°ãªãããŒãã®ã»ããã§æ§æã§ããã¢ãžã¥ã©ãŒ ã¹ã€ããã§ãã
- ãããã¯ãããŒã¿ã»ã³ã¿ãŒã§ã®åäœã«ç¹åãã VDX ããã³ SLX ã·ãªãŒãºã®ã¹ã€ããã§ãã
å°æ¥çã«ã¯ãäžèšã®ã¹ã€ãããšãã®æ©èœã«ã€ããŠèª¬æããããšæããŸãããããããããã¯å¥ã®èšäºã«ãªãã§ãããã
æåŸã«ããã XNUMX ã€éèŠãªããšã«ã€ããŠè§ŠããŠãããããšæããŸããèšäºã®ã©ãã«ã觊ããŠããŸããããExtreme ã¹ã€ããã¯ãæè¡çãŸãã¯æ³çèŠå¶ãªãã§ããµãŒãããŒã㣠ã¡ãŒã«ãŒã® SFP/SFP BASE-T/SFP+/QSFP/QSFP+ ããµããŒãããŠããŸãããµãŒãããŒãã£è£œã¢ãžã¥ãŒã«ã䜿çšããå¶é (Cisco ãªã©)ãããã - ãã©ã³ã·ãŒããŒãé«å質ã§ãããã¹ã€ããã«ãã£ãŠèªèãããå ŽåãåäœããŸãã
ãæž
èŽããããšãããããŸããããŸã次ã®èšäºã§ãäŒãããŸãããã ãããŠãããããèŠéããªãããã«ãæ°ããè³æã®åºçŸã远跡ã§ãããå
¬éãã以äžã«ç€ºããŸãã
-
-
-
-
åºæïŒ habr.com