ä»æ¥ã¯ VDI ã«ã€ããŠå°ãã話ããããšæããŸãã ç¹ã«ã倧äŒæ¥ã®çµå¶é£ã«ãšã£ãŠæãšããŠé倧ãªéžæåé¡ãåŒãèµ·ãããã®ã«ã€ããŠã¯ãèªåã§ããŒã«ã« ãœãªã¥ãŒã·ã§ã³ãçµç¹ãããããããªã㯠ã¯ã©ãŠãå ã®ãµãŒãã¹ã«å å ¥ããããã©ã¡ãã®ãªãã·ã§ã³ãåªå ããããšããããšã«ã€ããŠã§ãã åŸæ¥å¡æ°ãæ°çŸã§ã¯ãªãæ°åã®å Žåããã¹ãŠãå€§å¹ ãªè¿œå ã³ã¹ããšå€§å¹ ãªç¯çŽã®äž¡æ¹ã«ã€ãªããå¯èœæ§ããããããæé©ãªãœãªã¥ãŒã·ã§ã³ãéžæããããšãç¹ã«éèŠã§ãã
æ®å¿µãªãããæ®éçãªçãã¯æ±ºããŠãããŸãããåäŒæ¥ã¯åãªãã·ã§ã³ãèªç€Ÿã§ãè©Šããã詳现ã«èšç®ããå¿
èŠããããŸãã ãã ãã圹ç«ã€å¯èœæ§ããããšããŠãEvaluator Group ããã®èå³æ·±ãåæãå
±æããŸãã å瀟ã®å°é家ã¯ã20 幎以äžã«ããããæ
å ±ç®¡çãããŒã¿ã®ã¹ãã¬ãŒãžãšä¿è·ãã€ã³ãã©ã¹ãã©ã¯ã㣠IT ãœãªã¥ãŒã·ã§ã³ãææ°ã®ããŒã¿ã»ã³ã¿ãŒã®åéã§ç 究ãè¡ã£ãŠããŸããã æè¿çºè¡šããã調æ»ã§ã¯ã以äžã«åºã¥ããŠãªã³ãã¬ãã¹ VDI ãœãªã¥ãŒã·ã§ã³ã®ã³ã¹ããæ¯èŒããŸããã
ããæç¹ã§ã¯ãã¯ã©ãŠããåŸæ¥ã® IT ã€ã³ãã©ã¹ãã©ã¯ãã£ã®å¿
ç¶çãªåŸç¶ãšãªããšèããããŠããŸããã GmailãDropboxããã®ä»å€ãã®ã¯ã©ãŠã ãµãŒãã¹ãäžè¬çã«ãªããŸããã äŒæ¥ããããªã㯠ã¯ã©ãŠããç©æ¥µçã«å©çšãå§ããã«ã€ããã¯ã©ãŠãèªäœã®æŠå¿µãé²åããŸããã ãã¯ã©ãŠãã®ã¿ãã§ã¯ãªãããã€ããªããã¯ã©ãŠãããç»å Žãããã®ã¢ãã«ãå©çšããäŒæ¥ãå¢ããŠããŸãã äžè¬ã«ãäŒæ¥ã¯ç¹å®ã®ããŒã¿ããã³ã¢ããªã±ãŒã·ã§ã³ ã»ããã«ã¯ãããªã㯠ã¯ã©ãŠããé©ããŠããããã®ä»ã®ããŒã¿ããã³ã¢ããªã±ãŒã·ã§ã³ ã»ããã«ã¯ãªã³ãã¬ãã¹ ã€ã³ãã©ã¹ãã©ã¯ãã£ã®æ¹ãé©ããŠãããšèããŠããŸãã
ãããªã㯠ã¯ã©ãŠãã®å šäœçãªé åãšããããªã㯠ã¯ã©ãŠããç¹å®ã®çµç¹ã«é©ããŠãããã©ããã¯ãããã€ãã®èŠå ã«ãã£ãŠæ±ºãŸããŸãã ãããã«ã¯ãIT 人æã®ç¢ºä¿ãšãã®å°éç¥èã®ã¬ãã«ãäžè¬çãªç®¡çã¬ãã«ãããŒã¿ä¿è·ãã»ãã¥ãªãã£ã«é¢ããæžå¿µãè³é調éã«é¢ããäŒç€Ÿã®å¥œã¿ (åºå®è²»ãšå€åè²»ã«ã€ããŠè©±ããŠããŸã)ããããŠãã¡ããã³ã¹ããå«ãŸããŸããæ¢è£œã®ãœãªã¥ãŒã·ã§ã³ã®ã Evaluator Group ã®å°é家ã«ãã£ãŠå®æœãããå¥ã®èª¿æ» (ãäŒæ¥åããã€ããªãã ã¯ã©ãŠã ã¹ãã¬ãŒãžã) ã«ãããšãåçè ãéžæããäž»ãªèŠçŽ ã¯ã»ãã¥ãªãã£ãšã³ã¹ãã§ããã
ããŒã¿ã»ã³ã¿ãŒã§å®è¡ãããŠããä»ã®ã¢ããªã±ãŒã·ã§ã³ãšåæ§ã«ãVDI ã¯ããŸããŸãªãããªã㯠ã¯ã©ãŠã ãããã€ããŒãããµãŒãã¹ãšããŠå©çšã§ããŸãã VDI ã«ãããªã㯠ã¯ã©ãŠããéžæããäŒæ¥ã«ãšã£ãŠãäŸ¡æ Œã¯éèŠãªæ±ºå®èŠçŽ ã§ãã ãã®èª¿æ»ã§ã¯ããªã³ãã¬ãã¹ VDI ãœãªã¥ãŒã·ã§ã³ã®ç·ææã³ã¹ã (TCO) ãšãããªã㯠ã¯ã©ãŠã VDI ãœãªã¥ãŒã·ã§ã³ã®ç·ææã³ã¹ã (TCO) ãæ¯èŒããŸãã å ·äœçã«ã¯ããããã®ãœãªã¥ãŒã·ã§ã³ã«ã¯ãAmazon Cloud äžã® VMware Horizoâân ããã³ WorkSpaces ãåãã Dell EMC VxBlock 1000 ãå«ãŸããŸãã
TCO ã¢ãã«
ç·ææã³ã¹ãã¯ãIT æ©åšã®è³Œå ¥ãè©äŸ¡ããéã«äžè¬çã«äœ¿çšãããæŠå¿µã§ãã TCO ã§ã¯ãååŸã³ã¹ãã ãã§ãªããéžæããæ©åšã®å°å ¥ãšéçšã®ã³ã¹ããèæ ®ãããŸãã Dell EMC VxBlock 1000 ãªã©ã®çµ±åã€ã³ãã©ã¹ãã©ã¯ãã£ã¯ãåŸæ¥ã®ç°å¢ãç°¡çŽ åããèšèšãååŸãç¶ç¶çãªã¡ã³ããã³ã¹ã®ã³ã¹ããåæžããŸãã ããã«ãVMware Horizoâân ã¯ãä»æ¥ã®ãšã³ã¿ãŒãã©ã€ãº IT ã§åºãæ®åããŠãã VMware 補åãšã³ã·ã¹ãã ã®ä»ã®éšåãšç·å¯ã«çµ±åããããšã§ãéçšé¢ãç°¡çŽ åããŸãã
ãã®ãœãªã¥ãŒã·ã§ã³ã§ã¯ãDell EMC VxBlock 1000 ã® XNUMX ã€ã®ç°ãªããŠãŒã¶ãŒ ãããã¡ã€ã«ãèæ ®ããŸãã XNUMX ã€ç®ã®ãã¬ããž ã¯ãŒã«ãŒã¯ãåºæ¬çã«ãã³ã³ãã¥ãŒãã£ã³ã° ãªãœãŒã¹ã®èŠä»¶ãå¢ããããšãªããéåžžã®ãªãã£ã¹äœæ¥ã·ããªãªåãã«èšèšãããŠããŸãã XNUMX çªç®ã® Power Worker ã¯ãããéäžçãªã³ã³ãã¥ãŒãã£ã³ã°ãå¿ èŠãšããã¯ãŒã«ãŒã«é©ããŠããŸãã AWS WorkSpaces ã§ã¯ãããããæšæºãã³ãã«ãšããã©ãŒãã³ã¹ ãã³ãã«ã«ãããããããã³ã°ã§ããŸãã
ãŠãŒã¶ãŒãããã¡ã€ã«ã® VDI æ§æ
å°å ã®ã€ã³ãã©
Dell EMC VxBlock Converged System ã«ã¯ãDell EMC ã¹ãã¬ãŒãžãCISCO UCS ãµãŒããŒããã³ãããã¯ãŒãã³ã° ãœãªã¥ãŒã·ã§ã³ãVMware Horizoâân VDI ãœãããŠã§ã¢ ãã©ãããã©ãŒã ãå«ãŸããŠããŸãã ããŒã«ã« ã€ã³ãã©ã¹ãã©ã¯ãã£ã®å ŽåãVMware Horizoâân ãœãããŠã§ã¢ ã¹ã¿ãã¯ã¯æšæºã® x86 ãµãŒããŒã«ãããã€ããããŠãŒã¶ãŒæ°ã«å¿ããŠæ¡åŒµãããŸãã ãœãããŠã§ã¢ãšãŠãŒã¶ãŒ ã¢ã«ãŠã³ãã®ã¹ãã¬ãŒãžå®¹éã¯ããã¡ã€ã㌠ãã£ãã« SAN çµç±ã§æ¥ç¶ããããã©ãã·ã¥ ã¡ã¢ãª ã¢ã¬ã€ã«ãã£ãŠæäŸãããŸãã ã€ã³ãã©ã¹ãã©ã¯ãã£ã¯ãã·ã¹ãã 管çãç£èŠãèªååãæ åœããæšæº VxBlock ã³ã³ããŒãã³ãã§ãã Dell EMC AMP ã䜿çšããŠç®¡çãããŸããã
説æããã€ã³ãã©ã¹ãã©ã¯ãã£ã®ã¢ãŒããã¯ãã£ã以äžã®å³ã«ç€ºããŸãã ãã®ãœãªã¥ãŒã·ã§ã³ã¯ããšããš 2500 ã®ä»®æ³ãã¹ã¯ãããç°å¢åãã«èšèšãããŠãããåãèšèšå ã«æ°ããã³ã³ããŒãã³ããè¿œå ããããšã§æ倧 50 ã®ãã¹ã¯ããããŸã§æ¡åŒµã§ããŸãã ãã®èª¿æ»ã¯ã000 å°ã®ä»®æ³ãã¹ã¯ããããå«ãã€ã³ãã©ã¹ãã©ã¯ãã£ã«åºã¥ããŠããŸãã
Dell EMC VxBlock 1000 ã®ã¢ãŒããã¯ãã£èšèš
ãªã³ãã¬ãã¹ VDI ã€ã³ãã©ã¹ãã©ã¯ã㣠ã³ã³ããŒãã³ã
- Cisco UCS C240 M5 (2U) â 6138 ã€ã® Intel Xeon Gold 2 768 GHzãCisco Network AssistantãPower Worker ãããã¡ã€ã«çšã® 576 GB ã®ã¡ã¢ãªãããã³ Knowledge Worker ãããã¡ã€ã«çšã® XNUMX GB ã®ã¡ã¢ãªã SAN çµç±ã§æ¥ç¶ãããå€éšãã©ãã·ã¥ ã¢ã¬ã€ã¯ããŠãŒã¶ãŒ ããŒã¿ã®ã¹ãã¬ãŒãžãšããŠæ©èœããŸããã
- Cisco UCS C220 M5 SX (1U) â 4114 ã€ã® Intel Xeon Silver 2,2 192 GHzãCNAãããã³ XNUMX GB ã®ã¡ã¢ãªã ãããã®ãµãŒããŒã¯ãDell EMC Advanced Manager ãã©ãããã©ãŒã ããµããŒãããDell EMC Unity ã¹ã±ãŒã«ã¢ãŠã ã·ã¹ãã ã«ãã£ãŠæäŸãããã¹ãã¬ãŒãžãå ±æããŸãã
- Cisco Nexus 2232PP (1U) â 32 ããŒããFCoE 10 Gbit/s ãåããã¹ã€ããã å€æ°ã®ãµãŒããŒãååšããç°å¢ã«ååãªã¬ãã«ã®ã¢ã¯ã»ã¹ãæäŸããŸãã
- Cisco Nexus 9300 (1U) â 36 ããŒããåããã¹ã€ããã§ããšã³ã ãŠãŒã¶ã® IP ãããã¯ãŒã¯ãžã®æ¥ç¶ãæäŸããŸãã
- Cisco Nexus 6454 (1U) â ã³ã³ãã¥ãŒãã£ã³ã° ãµãŒããŒãIP ãããã¯ãŒã¯ãããã³ãã¡ã€ã㌠ãã£ãã« ãããã¯ãŒã¯ã«çµ±åãããã¯ãŒã¯æ¥ç¶ãæäŸãããµãŒããŒã
- Cisco 31108EC (1U) ã¯ãAMP ãµãŒããšã¹ãã¬ãŒãžãããã³ä»ã®ã³ã³ããŒãžã ã€ã³ãã©ã¹ãã©ã¯ãã£éã®æ¥ç¶ãæäŸãã 48 ããŒã 10/100 Gb ã€ãŒãµããã ã¹ã€ããã§ãã
- Cisco MDS 9396S (2U) ã¯ãXtremIO X48 ã¢ã¬ã€ã« SAN æ¥ç¶ãæäŸãã 2 ããŒãã®ãã¡ã€ã ãã£ãã« ã¹ã€ããã§ãã
- Dell EMC XtremIO X2 (5U) â 18 ã€ã®ã¢ã¯ãã£ã ã³ã³ãããŒã©ãŒãåãããã©ãã·ã¥ ã¡ã¢ãª ã¢ã¬ã€ã§ã4 x XNUMX TB SSD ã§æ§æãããŸãã ã«ã¹ã¿ã ãã¹ã¯ããããš VDI ãœãããŠã§ã¢ãæå¹ã«ããŸãã
- Dell EMC Unity 300 (2U) ã¯ã400/600 GB SSD ãš 10K HDD ãåãããã€ããªãã ããŒã¿ ã¹ãã¬ãŒãž ã¢ã¬ã€ã§ãã AMP ãã¡ããªãã¯ç®¡çãœãããŠã§ã¢ããµããŒãããæ©èœãæäŸããŸãã
- VMware Horizoâân ã¯ãäŒæ¥ç°å¢ã§ä»®æ³ãã¹ã¯ãããã管çããããã®ä»®æ³åãœãããŠã§ã¢ ãã©ãããã©ãŒã ã§ãã vSphere ãã€ããŒãã€ã¶ãŒã¯ãVMware Horizoâân ã®äžéšãšããŠã©ã€ã»ã³ã¹ãããŠããŸãã
TCO ãèŠç©ããããã«ããã®èª¿æ»ã§ã¯å©æ¯ãªãã®åçŽãª XNUMX 幎éã®æžäŸ¡ååŽã䜿çšããŸããã ãã®ãããªæ©åšã®è³Œå ¥ã®å®çŸå¯èœæ§ãè©äŸ¡ãããçµç¹ã¯ããªãŒã¹ã³ã¹ããå éšãœãŒã¹ããã®è³æ¬ãç°¡åã«èšç®ã«è¿œå ã§ãããšèããããŸãã
ä¿å®ã³ã¹ã㯠2000U ãããæé¡ 42 ãã«ãšèŠç©ããããŠãããããã«ã¯é»æºãå·åŽãã©ã㯠ã¹ããŒã¹ã®ã³ã¹ããå«ãŸããŸãã åãµãŒããŒã®ç®¡çã«ã¯ 0,2 é±éããã 150 æéããããšæšå®ãããŸããã åã¹ãã¬ãŒãž ã·ã¹ãã ã®æŽæ°ãšã¡ã³ããã³ã¹ã«ã¯ãé±ã« 000 æéããããŸãã 管çè ã®æéåœããã®æ絊ã¯ã次ã®åŒã䜿çšããŠèšç®ãããŸãããããã«è² è·ã® IT 管çè ã®å¹Žéæ絊 (2000 ãã«) / 幎é XNUMX åŽåæéãã
ç·ææã³ã¹ãã®èšç®
ã·ã¹ãã ã¯ããªãå€ãã®ç°ãªãã³ã³ããŒãã³ãã§æ§æãããŠãããšããäºå®ã«ãããããããå®éã®ã³ã¹ãèšç®ã¯éåžžã«ç°¡åã§ããããšãããããŸãã äŸãšããŠããã¬ããž ã¯ãŒã«ãŒ ãããã¡ã€ã«ã® 5000 ãŠãŒã¶ãŒåãã«èšèšãããç°å¢ãåãäžããŸããã åãæ¹æ³ã䜿çšããŠã以äžã«ç€ºãã°ã©ãã®æ¯èŒå€ãååŸããŸããã ãããã®ãœãããŠã§ã¢ãããŒããŠã§ã¢ããã³ãµããŒãã®ã³ã¹ãã¯ãæšæºå²åŒãå«ããããŒããŠã§ã¢ããã³ç®¡çã³ã¹ããšãšãã« 3 幎éã®æææéã«ããã£ãŠåèšãããŸããã
5000 人ã®ãã¬ããž ã¯ãŒã«ãŒã® VDI ã€ã³ãã©ã¹ãã©ã¯ãã£ã®ã³ã¹ã:
- ãµãŒã㌠(ã³ã³ãã¥ãŒãã£ã³ã°ããã³ç®¡ç) â 1 ãã«
- ããŒã¿ã¹ãã¬ãŒãž (VDI ã·ã¹ãã ããŠãŒã¶ãŒããŒã¿ã管çã·ã¹ãã ) â 315 ãã«
- ãããã¯ãŒã¯ (LAN ããã³ SAN ã¹ã€ããããã®ä»ã®æ©åš) â 253 ãã«
- ãœãããŠã§ã¢ (VDI ãã©ãããã©ãŒã ã管çãããŒããŠã§ã¢ã«ãªã³ã¯ãããã©ã€ã»ã³ã¹) â 2 ãã«
- ãµããŒã (ãœãããŠã§ã¢ãšãââãŒããŠã§ã¢ã®ã¡ã³ããã³ã¹ãšæŽæ°) â 224 ãã«
- ãµãŒãã¹ (ããŒããŠã§ã¢ããã³ãœãããŠã§ã¢ã®å°å ¥) â 78 ãã«
- 3 幎éã®ã¡ã³ããã³ã¹è²»çš: $226
- 3 幎éã®ç®¡çè²»: 161 ãã«
- åèš: 5ãã«
ä»®æ³ãã¹ã¯ãããã®ç·ã³ã¹ããåŸæ¥å¡ 5000 人ã§å²ã£ãŠãã 36 ãæã§å²ããšãäŸ¡æ Œã¯æ¬¡ã®ããã«ãªããŸãã $28,52 ãã¬ããž ã¯ãŒã«ãŒ ãããã¡ã€ã« ãŠãŒã¶ãŒããšã«æãããã
ãããªãã¯ã¯ã©ãŠãã€ã³ãã©ã¹ãã©ã¯ãã£
Amazon WorkSpaces ã¯ããã¹ãŠã AWS ã¯ã©ãŠãå ã§å®è¡ããããµãŒãã¹ãšããŠã® VDI ã§ãã Windows ãã¹ã¯ããããš Linux ãã¹ã¯ãããã®äž¡æ¹ãæäŸãããæããšãŸãã¯æéããšã«è«æ±ã§ããŸãã 調æ»æç¹ã§ã¯ã5 vCPU ãš 1 GB RAM ãã 2 vCPU ãš 8 GB RAM ãšã¹ãã¬ãŒãžãŸã§ãããŸããŸãªã·ã¹ãã æ§æ㧠32 ã€ã®åºæ¬ããã±ãŒãžãæäŸãããŠããŸããã ãã® TCO æ¯èŒã®åºç€ãšã㊠XNUMX ã€ã® Linux ãã¹ã¯ãããæ§æãéžæãããŸããã ãã®äŸ¡æ Œã¯ãWindows ã©ã€ã»ã³ã¹ã® Bring Your Own ã³ã³ã»ããã«ãé©çšãããŸãã å®éãå€ãã®äŒæ¥ã¯ãã§ã«ãã€ã¯ããœãããšå€§èŠæš¡ãªé·æãšã³ã¿ãŒãã©ã€ãº ã©ã€ã»ã³ã¹å¥çŽ (ELA - ãšã³ã¿ãŒãã©ã€ãº ã©ã€ã»ã³ã¹å¥çŽ) ãçµãã§ããŸãã
- æšæºããã±ãŒãž: ãã¬ããž ã¯ãŒã«ãŒ ã·ããªãªã®å Žåã2vCPUããã¹ã¯ãããã« 4 GB RAMãã«ãŒã ããªã¥ãŒã ã« 80 GBããŠãŒã¶ãŒ ããªã¥ãŒã ã« 10 GB - æé¡ 30,83 ãã«ã
- ããã©ãŒãã³ã¹ ããã±ãŒãž: 2vCPUã7,5 GB ãã¹ã¯ããã RAMã80 GB ã«ãŒã ããªã¥ãŒã ãPower Worker çšã® 10 GB ãŠãŒã¶ãŒ ããªã¥ãŒã - æé¡ 53,91 ãã«ã
ã©ã¡ãã®ããã±ãŒãžã«ããã«ãŒã (ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ããã³é¢é£ãã¡ã€ã«çšã« 80 GB) ããªã¥ãŒã ãšãŠãŒã¶ãŒ (åŸæ¥å¡ããŒã¿çšã« 10 GB) ããªã¥ãŒã ãå«ãŸããŠããŸãã åæ¢ãçºçããªããšä»®å®ãããšãAmazon ã¯å¶éãè¶ ããã®ã¬ãã€ãããšã«æéãè«æ±ããããšã«æ³šæããŠãã ããã ããã«ã衚瀺ãããŠããäŸ¡æ Œã«ã¯ãAWS ããã€ã³ã¿ãŒãããçµç±ã§ããŒã¿ã転éããã³ã¹ããããã³ãŠãŒã¶ãŒã®ã€ã³ã¿ãŒãããã³ã¹ãã¯å«ãŸããŠããŸããã èšç®ãç°¡åã«ããããã«ããã®ç 究ã®èšç®ã¢ãã«ã§ã¯ãåä¿¡ããŒã¿ãšéä¿¡ããŒã¿ã®éä¿¡ã«ã³ã¹ããããããªãããšãåæãšããŠããŸãã
äžèšã®æéãã©ã³ã«ã¯ã·ã¹ãã ãã¬ãŒãã³ã°ã¯å«ãŸããŠããŸããããAWS ããžãã¹ãµããŒãã¯å«ãŸããŠããŸãã äžèšã®ãŠãŒã¶ãŒãããã®ã³ã¹ãã¯åºå®ã§ããããã®ãããªãµããŒãã®ã³ã¹ãã¯ã7 ãŠãŒã¶ãŒã®ããŒã«ã®å Žåã¯ãŠãŒã¶ãŒãããçŽ 2500% ããã3 ãŠãŒã¶ãŒã®ããŒã«ã®å Žåã¯ãŠãŒã¶ãŒãããçŽ 50% ãŸã§å€åããŸãã ããã¯èšç®æã«èæ ®ãããŸãã
ããã¯æå¹æéã®ãªããªã³ããã³ãæéã¢ãã«ã§ããããšãä»ãå ããŠãããŸãã é éãè¶ ããŠåæããããªãã·ã§ã³ã¯ãªããéåžžã¯æéãé·ããªãã«ã€ããŠã³ã¹ããåæžãããé·æãµãã¹ã¯ãªãã·ã§ã³ããããŸããã ããã«ãèšç®ã容æã«ããããã«ããã® TCO ã¢ãã«ã§ã¯ãçæã®å²åŒããã®ä»ã®ããã¢ãŒã·ã§ã³ç¹å žã¯èæ ®ãããŠããŸããã ãã ãããã®æ¯èŒã®æ çµã¿å ã§ã¯ããããã®åœ±é¿ã¯ãããã«ããŠãéèŠã§ã¯ãããŸããã§ããã
çµæ
ãã¬ããžã¯ãŒã«ãŒã®ãããã£ãŒã«
以äžã®ã°ã©ãã¯ããŠãŒã¶ãŒ ããŒã«ã 1000 人ãè¶ ããªãå ŽåãVDI çšã®ãªã³ãã¬ãã¹ã® Dell EMC VxBlock 2500 ãœãªã¥ãŒã·ã§ã³ã®éå§ã³ã¹ãããAWS WorkSpaces ã¯ã©ãŠã ãœãªã¥ãŒã·ã§ã³ãšã»ãŒåãéé¡ã«ãªãããšã瀺ããŠããŸãã ããããä»®æ³ãã¹ã¯ãããã®æ°ãå¢å ããã«ã€ããŠããã¹ãŠãå€ããã€ã€ãããŸãã ãŠãŒã¶ãŒã 5000 人ã®äŒæ¥ã®å ŽåãVxBlock ã¯ãã§ã«çŽ 7% å®ããªãã20 ã®ä»®æ³ãã¹ã¯ããããå±éããå¿ èŠãããäŒæ¥ã®å ŽåãVxBlock 㯠AWS ã¯ã©ãŠããšæ¯èŒã㊠000% 以äžç¯çŽã§ããŸãã
ãã¬ããž ã¯ãŒã«ãŒ ãããã¡ã€ã«çšã® VxBlock ãš AWS WorkSpaces ã«åºã¥ã VDI ãœãªã¥ãŒã·ã§ã³ã®ã³ã¹ãæ¯èŒãä»®æ³ãã¹ã¯ããããããã®æé¡æé
ãã¯ãŒã¯ãŒã«ãŒã®ãããã£ãŒã«
次ã®ã°ã©ãã¯ãVxBlock ããŒã¹ã®ãªã³ãã¬ãã¹ VDI ã® Power Worker ãããã¡ã€ã«ã® TCO ãš AWS WorkSpaces ã®ããã©ãŒãã³ã¹ ããã±ãŒãžãæ¯èŒããŠããŸãã ããã§ã¯ããã¬ããž ã¯ãŒã«ãŒ ãããã¡ã€ã«ãšã¯ç°ãªããããŒããŠã§ã¢ã«ãéããããããšã«æ³šæããŠãã ãããVxBlock ã§ã¯ 4 ã€ã® vCPU ãš 8 GB ã®ã¡ã¢ãªããããAWS ã§ã¯ 2 ã€ã® vCPU ãš 7,5 GB ã®ã¡ã¢ãªã§ãã ããã§ãVxBlock ãœãªã¥ãŒã·ã§ã³ã¯ 2500 ãŠãŒã¶ãŒã®ããŒã«å ã§ãèããåçæ§ãé«ãããšãå€æããå šäœçãªç¯çŽç㯠30 ïœ 45% ã«éããŸãã
Power Worker ãããã¡ã€ã«çšã® VxBlock ãš AWS WorkSpaces ã«åºã¥ã VDI ãœãªã¥ãŒã·ã§ã³ã®ã³ã¹ãæ¯èŒãä»®æ³ãã¹ã¯ããããããã®æé¡æé
3幎åŸã®èŠéã
ãŠãŒã¶ãŒãããã®å¹³åã³ã¹ãã«å ããŠãäŒæ¥ã«ãšã£ãŠã¯ãéžæããã€ã³ãã©ã¹ãã©ã¯ã㣠ãœãªã¥ãŒã·ã§ã³ã«ããç¯çŽé¡ãè€æ°å¹Žã«ããã£ãŠè©äŸ¡ããããšãéèŠã§ãã æåŸã®ã°ã©ãã¯ã36 ãæã«ãããç·ææã³ã¹ãã®éããã©ã®ããã«ããŠç®èŠãŸãã环ç©çãªçµæžçå©çãçã¿åºããã瀺ããŠããŸãã 10 å°ã®ä»®æ³ãã¹ã¯ãããã® Power Worker ã·ããªãªã§ã¯ãAWS ãœãªã¥ãŒã·ã§ã³ã¯ VxBlock ãœãªã¥ãŒã·ã§ã³ãããçŽ 000 äžãã«é«äŸ¡ã§ãã ãã¬ããž ã¯ãŒã«ãŒã®ã·ããªãªã§ã¯ãåãæéãåããŠãŒã¶ãŒæ°ã§ã环èšã®ç¯çŽé¡ã¯ 8,5 äžãã«ã«éããŸãã
10 人㮠Power Worker ãŠãŒã¶ãŒåãã«ããªã³ãã¬ãã¹ã® VxBlock ãš AWS WorkSpaces ãããªã㯠ã¯ã©ãŠãäžã§ 000 å°ã®ä»®æ³ãã¹ã¯ããããç¶æããããã®ç·ã³ã¹ã
ãªã³ãã¬ãã¹ VDI ãœãªã¥ãŒã·ã§ã³ã®ã³ã¹ããäœãã®ã¯ãªãã§ãã?
äžã®ã°ã©ãã®ãªã³ãã¬ãã¹ VDI ãœãªã¥ãŒã·ã§ã³ã«ããã³ã¹ãåæžã¯ãèŠæš¡ã®çµæžãšãªãœãŒã¹ã®æ倧åãšãã XNUMX ã€ã®åºæ¬ååãåæ ããŠããŸãã ä»ã®ã€ã³ãã©ã¹ãã©ã¯ãã£ã®è³Œå ¥ãšåæ§ããã®ãšã³ã¿ãŒãã©ã€ãº ã³ã³ãã¥ãŒãã£ã³ã°ç°å¢ã«ãã·ã¹ãã ãæ§ç¯ããããã®åæè²»çšãããããŸãã åæã³ã¹ããæ¡å€§ããŠããå€ãã®ãŠãŒã¶ãŒã«åæ£ãããšãè¿œå ã³ã¹ããäžãããŸãã ãŸããVDI ã¯ãCPU ã³ã¢ã®å²ãåœãŠã管çããããšã«ããããªãœãŒã¹ã®äœ¿çšçãæé©åããŸãã ããŒã¿ãèšç®ããããã¯ãŒã¯ã®æœè±¡åã«ããããããã®ã·ã¹ãã ã¯ç©çãªãœãŒã¹ãç¹å®ã®æ¯çã§ããªãŒããŒãµãã¹ã¯ã©ã€ããã§ããããããŠãŒã¶ãŒã®ã³ã¹ããåæžãããŸãã ãããªã㯠ã¯ã©ãŠãã®ãããªå€§èŠæš¡ç°å¢ã§ã¯ãåæ§ã®ã³ã¹ãåæžååãå€ãæ¡çšãããŠããŸããããã®åæžåããŠãŒã¶ãŒã«éå ãããããšã¯ãããŸããã
5幎ã®åšè·æéã¯ã©ãã§ããããïŒ
å®éãå€ãã®çµç¹ã¯ IT ã·ã¹ãã ã 3 幎以äžç¶æããŠããããã®æéã 4 ïœ 5 幎ã«éããããšããããããŸãã Dell EMC VxBlock 1000 ã·ã¹ãã ã¯ããŸã£ããæ°ããã·ã¹ãã ã«çªç¶ç§»è¡ããããšãªããåã ã®ã³ã³ããŒãã³ããã¢ããã°ã¬ãŒãããããæ¢åã®ã³ã³ããŒãã³ããã¢ããã°ã¬ãŒããããã§ããã¢ãŒããã¯ãã£ã念é ã«çœ®ããŠæ§ç¯ãããŠããŸãã
ãã®ã¢ãã«ã®åºå®è²»ãšå€åè²»ã 5 幎éã§è¡šããšãçŽ 37% æžå°ããŸã (ããã« 1000 幎éã®ç®¡çãšãµããŒããé€ã)ã ãã®çµæã5000 人ã®ãã¬ããž ã¯ãŒã«ãŒåãã® Dell EMC VxBlock 28,52 ã«åºã¥ãããŒã«ã« VDI ãœãªã¥ãŒã·ã§ã³ã®è²»çšã¯ã17,98 ãã«ã§ã¯ãªãããŠãŒã¶ãŒããã 5000 ãã«ã«ãªããŸãã 34,38 人㮠Power Worker ã®å ŽåããŠãŒã¶ãŒãããã®ã³ã¹ã㯠21,66 ãã«ãã 5 ãã«ã«äžãããŸãã åæã«ãAWS WorkSpaces ã¯ã©ãŠã ãœãªã¥ãŒã·ã§ã³ã®äŸ¡æ Œã¯åºå®ã®ãããXNUMX 幎éã®ã³ã¹ãã¯å€ãããŸããã
ãŠãŒã¶ãŒãšã¯ã¹ããªãšã³ã¹ãšãªã¹ã¯
VDI ã¯ããã¹ãŠã®åŸæ¥å¡ã«åœ±é¿ãäžããäŒç€Ÿã®æé«ã¬ãã«ãžã®ã¢ã¯ã»ã¹ãæäŸããããã·ã§ã³ã¯ãªãã£ã«ã«ãªã¢ããªã±ãŒã·ã§ã³ã§ãã åŸæ¥å¡èªèº«ã®ãã¹ã¯ãããã VDI (ã¯ã©ãŠãã§ããªã³ãã¬ãã¹ã§ã) ã«çœ®ãæããå ŽåããŠãŒã¶ãŒ ãšã¯ã¹ããªãšã³ã¹ã¯åãã§ããå¿ èŠããããããæœåšçãªãªã¹ã¯ãè©äŸ¡ããããšãéèŠã§ãã VDI ã·ã¹ãã ãé©åãªå Žæã«ç¶æãããšãã€ã³ãã©ã¹ãã©ã¯ãã£ã®å¶åŸ¡ã匷åããããã®ãããªãªã¹ã¯ã軜æžã§ããå¯èœæ§ããããŸãã
ã¯ã©ãŠã ãã¹ã¯ããã ãµãŒãã¹ããããªã㯠ã€ã³ã¿ãŒãããã®æ¥ç¶ãšåž¯åå¹ ã«äŸåãããšãç°å¢ã«æ°ããªãªã¹ã¯ãè¿œå ãããå¯èœæ§ããããŸãã ããã«ãåŸæ¥å¡ã¯ USB ã¹ãã¬ãŒãžããã€ã¹ãåšèŸºæ©åšã䜿çšããããšããããããŸããããã®å€ã㯠AWS WorkSpaces ã§ãµããŒããããŠããŸããã
ãããªã㯠ã¯ã©ãŠããé©ããŠããã®ã¯ã©ã®ãããªç¶æ³ã§ãã?
AWS WorkSpaces ã®æéã¯ããŠãŒã¶ãŒããšããŸãã¯æåäœã§èšå®ãããŸãã ããã¯ãçæéã§ã¢ããªã±ãŒã·ã§ã³ãèµ·åããå Žåããéçºã«ãããŠãã¹ãŠãæçæéã§å®è£ ããå¿ èŠãããå Žåã«äŸ¿å©ã§ãã ããã«ããã®ãªãã·ã§ã³ã¯ãIT ã«é¢ããæ·±ãå°éç¥èãè³æ¬æ¯åºãè¡ãæ欲ãèœåãæããªãäŒæ¥ã«ãšã£ãŠã¯é åçã§ããå¯èœæ§ããããŸãã ãŸãããããªã㯠ã¯ã©ãŠãã® VDI ã¯ãäžå°äŒæ¥ãçæçãªã¢ããªã±ãŒã·ã§ã³ã倧äŒæ¥ã®ãã¹ã¯ãããä»®æ³åãªã©ã®ã³ã¢ IT ãµãŒãã¹ã«é¢é£ããã¿ã¹ã¯ã«ã¯é©ããŠããŸããããã®ãªãã·ã§ã³ã¯ãã¯ãå®å šã«ã¯é©ããŠããªãå¯èœæ§ããããŸãã
ãŸãšããšçµè«
VDI ã¯ããŠãŒã¶ãŒã®ã³ã³ãã¥ãŒãã£ã³ã° ã¢ããªã±ãŒã·ã§ã³ãšã€ã³ãã©ã¹ãã©ã¯ãã£ããã¹ã¯ãããããããŒã¿ ã»ã³ã¿ãŒã«ç§»åãããã¯ãããžãŒã§ãã ããæå³ã§ã¯ããã¹ã¯ããã管çãšãªãœãŒã¹ãå°çšãµãŒããŒãšå ±æã¹ãã¬ãŒãžã«çµ±åããããšã§ãã¯ã©ãŠãã®å©ç¹ã®äžéšãæäŸããŸãã ããã«ããã管çã³ã¹ããåæžããããªãœãŒã¹ã®äœ¿çšãæé©åãããã³ã¹ããåæžãããŸãã å®éãã»ãšãã©ã® VDI ãããžã§ã¯ã㯠(å°ãªããšãéšåçã«ã¯) äŒæ¥ã®ã³ã¹ãåæžã®å¿ èŠæ§ã«ãã£ãŠæšé²ãããŠããŸãã
ã§ã¯ããããªã㯠ã¯ã©ãŠã㧠VDI ãå®è¡ããå Žåã¯ã©ãã§ãããã? ããã«ããããªã³ãã¬ãã¹ VDI ãããã³ã¹ããåæžã§ããŸãã? å°èŠæš¡ãªçµç¹ãçæéã®å°å ¥ã®å Žåã¯ããããããã®ãšããã§ãã ããããæ°åãŸãã¯æ°äžã®ãã¹ã¯ãããããµããŒããããçµç¹ã«ãšã£ãŠãçãã¯ãããŒãã§ãã 倧èŠæš¡ãªäŒæ¥ã® VDI ãããžã§ã¯ãã®å Žåãã¯ã©ãŠãã¯ããªãé«äŸ¡ã§ããããšãããããŸãã
ãã® TCO 調æ»ã§ãEvaluator Group ã¯ãDell EMC VxBlock 1000 ãš VMware Horizoâân ãå®è¡ãããªã³ãã¬ãã¹ VDI ãœãªã¥ãŒã·ã§ã³ã®ã³ã¹ãããAWS WorkSpaces ã䜿çšããã¯ã©ãŠã VDI ã®ã³ã¹ããšæ¯èŒããŸããã ãã®çµæã5000 人ãŸã㯠10 人以äžã®ãã¬ããž ã¯ãŒã«ãŒãããç°å¢ã§ã¯ãã¹ã±ãŒã«ã¡ãªããã«ãã£ãŠãã¹ã¯ããããããã®ãªã³ãã¬ãã¹ VDI ã®ã³ã¹ãã 000% 以äžåæžãããäžæ¹ãã¯ã©ãŠã VDI ã®ã³ã¹ãã¯ãŠãŒã¶ãŒæ°ãå¢å ããŠãå®è³ªçã«å€ãããªãããšãããããŸããã Power Workers ã®å Žåãã³ã¹ãã®å·®ã¯ããã«å€§ãããVxBlock ããŒã¹ã®ãœãªã¥ãŒã·ã§ã³ã¯ AWS ããã 20 ïœ 30% ã³ã¹ãå¹çãé«ãã£ãã§ãã
Dell EMC VxBlock 1000 ãœãªã¥ãŒã·ã§ã³ã¯ãã³ã¹ãã®éããè¶ ããŠãIT 管çè ã«ããåªãããŠãŒã¶ãŒ ãšã¯ã¹ããªãšã³ã¹ãšããé«åºŠãªå¶åŸ¡ãæäŸããŸãã ç¹ã«ãããŒã«ã« ãããã¯ãŒã¯çšã® VDI ãœãªã¥ãŒã·ã§ã³ã¯ãã»ãã¥ãªãã£ãããã©ãŒãã³ã¹ãããŒã¿è»¢éã«é¢é£ããå€ãã®æœåšçãªãªã¹ã¯ãåé¿ããŸãã
ç 究ã®èè
â
ããã ãã§ãã æåŸãŸã§èªãã§ããã ãããããšãããããŸããïŒ ã·ã¹ãã ã«ã€ããŠè©³ããèŠã
åºæïŒ habr.com