α’αααα’αΆαααααΌαααΆαα’ααααΎαα±ααααααΆαααααα½αα―αα’αααΈαααααΆαααααααΆαααΆααααα αααααΆαα ααΆαααααααααααα’ααα±αα ααααααα α»ααααααΆαααα ααααΆαααααΆαααΌα αα αααα»αααααααααααα·αααααααααα½α αααααΉαααααΌαααΆααα·ααΆααααΆαααΆααααα’α·ααα αααα»αα’αααααααααΈαα
αααααααααΆα
αααααα αααααααααβαα·αααααα (αααααααααααααΎαααΆααα·αααααα) α’αΆα ααααΌαααΆααααααααΆααΆα
- αααΆαααααααΆαααααα½αααααα’ααααα αααα»α "αααααααααΆαααΈααα" ααααΆαααααα½αααααα’ααααα αααα»αααα·ααααααα ααααΆα ααααααααααΆααααααΌαααΆαα’αααααααΆαααααΆααααΆαααααααααααααΆααα αα·αα§ααααααααααΆαα ααααααΆααααΆαα’ααΈαααΊαα·αααΆααααα’ααααααααααααΆα―αααΆαααααΈαα
- rack αα½αααΆαα½αα§αααααααααΆαααααα½αααααααΆαααααΆαααΈααΆαααα ααααααααααα·αααααααα·αααααΆαα - α’αααΈαααααα α ααΆα ααΆααααααΌααααα»αααααΆ αααα’αα»αααααΆααααααααΆαααααΆααααΈ III α¬ααΈ IV α αΎααααααΆααΆααΆαααααααααααααΆααααααα’αΆα αα»αα α·αααααΆα ααΆααααααΆαα αα·αααΆαα αΌαααααΎα’ααΈαααΊαα·αααααααααααΆαααΉαααα α»αα
- α§ααααααα½ααααααααα αααα»αααααααααααα·ααααααααααα·α III α¬ IV α
αααααΎαααααααααααΆαααα αα½αααΆαααααααΌαααααΎαααΎαααΊαα»αααααα αααα»αααααΈααΈαα½αα α αΎαααΆααααααΆα’αΆαααααααΎαααααΆααααΆααααα½αα ααα½αα
- α ααα»α’αααΈααΆαααΆαα ααααΆαααααΌαααΆαα αααααΆαα ααΆαααααααα IT ααααΆαααααα½α?
- ααΎαα ααααΆαα ααααΆαα’αααΈααΈα αααααΆαα ααΆααααααααααααααΆααα·ααααΆ (ααΆαααΏααΆαα ααΆαααααααΆα ααΆααααααααααααα);
- ααα·ααΆαααααΆααα·αα·αααααααΌααα αααα»αα αααααΆαα ααΆααααααααααααααΆααα·ααααΆ ααααΌα ααΆααΆαα αααΆαααΎααααααααΆααα - ααΎααα»α (αααααΆααααααΆα’ααααα·αα§αααααααααΆαααααα½αααααα’ααα) α¬ααααα·ααααα·ααΆα (α§αααααααΆααααααΆααααΌαααΆααα½α);
- αααααΆαααααααααα ααααΆααααα½αα―αα
ααΆα αααΎαα’αΆα ααααΌαααΆααααααα’αααΈαααααΆαααααα₯αααα·αααααααΆααααααα α α·ααααααααα ααααΆααααα»αααΆααααααΎα αα·αααααΎααααΆααα αααααΆαα ααΆαααααααα IT αααααααα½α ααα»ααααααααα ααααααΎαααΊααΎααααΈαααα αΆααααα»αααΆαα’αα»ααααααΈαααααααααΎαα αααααΆαα ααΆααααααααααα ααΎααααΈα±ααααΆααΆαααΆαα’ααααααα αα·αα’αΆα αααααααααΆαααααααα β ααΆααααααα ααΆαα αααΆαααΎααΆααα·ααααααα·ααΈααΆαα·ααααααα α¬αααααΆαααΆααΆααα’ααααααΆα
ααΌα αααααΆαα’αα»ααααααααααααααααα αΆα ααΆαα·αααΆαααααααααα»αααΆααααααααΎαααααααΉαααααα α αΆααααΆααααΈααΆα stingy α αααΆαααΈααα αα·αααΌααααΈααα αααΎααααα ααα»ααααααΆααααΈααααααα Hardware ααα’ααααΆααααααΆααΆαααααΆαααα»ααααα α αΎααα ααΈαααα αα α’αααΈαααααααΌααα·α αα·ααααααααα»ααααΆαα’αΆαααααααΎαααααααΆααααααα ααααΆα αα·α "ααΆααααααα" ααααΆααααααααααααααααΆα ααΎαααΈααα ααΆααα "αααααα" αα½αααααααΌαααΆαααααααα»ααααααα’ααααΆααα αααααααΆααΆααΆααααααΎααααα»αααΆααα·αα·αααααΎαααααααΉααα ααααΆααααΆαααααΌα ααΎααααΈαα»αα±ααααΆααααα αΆαααααααααααΆαα½αααΉαααΆαααΆαααα αα·αααΆαααααΎααΆαααααααΆαααααααΆ α αΆααααΆααααΈααΆαααααΎαααααΆαααααΌααα·αααααΉαααααΌα αα·α ααΆααααααα αααΎαα α½αα ααα»α’αΆα ααΆαα±ααααΆαααΆαα αααΆααααααααΆααααα αΆααααααΎαααααααα
ααΌα αααααα·ααααααααααΌααααααΆααααααααα
- ααΆααα ααααΆααα½ααααααΆααααααα α α·ααααααααΎααα·αααααααααΆαααααα½α αα·αααΆααααααααααΆααααααααα½ααα ααΆααα’ααΈαααΊαα·αα
- αααα»αα αα»αααΆααααααα α α·ααααα½α rack ααΎααααΈααΆααα§ααααααααααααα½ααα αααα»αααααααααααα·ααααααααααα’αααααΆαααΆααααααΆααααααααΆααααααααΆα Tier III α
- αααα»αα αα»αααΆααααααα α α·ααααα·ααααααα αααΎαααΎαααααααΉα α αΎαααΌα ααααααΆααα·αα§αααααααΆααααααααΆαα½αααΉαααΆαααΆααΆ αα·αααΆαααΆααααααααααα
αααααΈα§ααααα
- αααΆαααΈααα Dell PowerEdge R640 α ααα½αααΈαααΌα ααΆααααααα
- ααααΎαααΆα Intel Xeon Gold 5120 α ααα½αααΈα
- RAM ααα α α€ ααΈα
- ααΆα SAS ααΈααα αααα»α RAID1 αααααΆααααΆαααα‘αΎαααααααααααααα·ααααα·ααΆα
- ααΆααααααΆα 4-port 1G αααααααΆααααααΆαα½α
- ααΆααααααΆα 2-port 10G α ααα½αααΈα
- αα½αα ααα FC HBA 2G 16 α αααα
- αααααααααααα»α 2-controller Dell MD3820f, ααααΆααααΆαααα FC 16G αααααααΆαααα ααΆαα Dell hosts;
- αα»αααΆααααααα·αααΈααΈαααΈα - Cisco WS-C2960RX-48FPS-L ααα;
- αα»αααΆααααααα·αααΈααΈααΈα - Cisco WS-C3850-24T-E, ααα;
- Rack, UPS, PDU, console servers ααααΌαααΆαααααααααααααααααααα·ααααααα
ααΌα αααααΎαααΎα α§ααααααααααΆαααααΆααααΆαααααααα·αααααα’αααααΆααααΆαααααΎααΆαααααααΆαααααα αα·αααααα ααααα·αααΎαα ααααΆαα’αΆα ααααα½αααααααααΆαα½ααααα»αα αα»ααααααααααααααΆαααααααααααααααααΆαα ααΎα’ααΈαααΊαα·α α αΎαα αΆααααααΎαααα½αααΆαααααΆααα αααα αααα’αΆα αα·αα·ααααααα»αααΆααααααΈαααααΆααααααΆααααΆαααααα½ααααααααααααααααα αα·αααααΎαααααΆααα ααααα
ααΎα§αααααα’αααΈαααααααααΎαα’αΆα ααααααααααα·αααΎαα ααααΆααααααα α α·ααααααααΎαααααΎαααΆαααα ααααααα»αααααΌαααααααααΎαα
- ααΎαααΆααα»ααααα»ααααααα½ααα αααα»αα ααα½αα ααααα ααΎαα»αααΆαα 2960X αααααΆααααααΆααΎαα’αΆα αααααααααΆαααΈααααααααααΉααααααααααα
- αα·ααα»αααΆαα FC ααααααααΈαααΎααααΈααααΆαααααααααααααα»α αα·ααααΆαααΈααααααααααα αα½αααα
- αααΆαααΈααααααααΆαααααΆααα’αΆα ααααΌαααΆαααα‘αΎααααα - ααααααα’αααα αα αΆα αααα½αααααααααααααΎαααΆααααααΆαααΆαααααααΆααααΆα ααααΆαααα αααααΆα 10G αααααααΎα’αΆααΆααααααααααΆααααααΆαααααΆααα
- α’αααα’αΆα ααααααααααΎαααΆααααααααα αααααααααααα»ααα·ααααααααΆαα½αααΉαααααααααΆααααααααΌαααΆα - SAS, SATA α¬ SSD α’αΆαααααααΎααααα»ααααααΆαααααααα»αα
- αααααΆααααΈαααααααα»αααΆαα FC α’αααα’αΆα αα·ααααααααααααα»ααααααααα ααΎααααΈααααααααα αααΆαααΆααααα αααΎα α αΎαααααα·αααΎα’ααααα·ααααααΎαα ααααααΈα ααααΆααα·ααααα ααΆ α’αααα’αΆα αααα αααΆαα αααααα·αααααααααΆααααααααααααα»ααα·ααααααααΆαααα αααα»αααααααααααα·ααααααααΌα ααααΆ αα·ααααΆαααααααααααα·αααααα ( ααα»αααααααααΊααΎαααΈαα·ααΆαααΆαααα’ααααααα½α α αΎα);
- ααΆααααΆααα»αααΆααααααα·αααΈααΈααααα - Cisco 3850 αααα’αΆα ααααΌαααΆαααααΎααΆααααΌααααααΆααααα’ααα±αα ααααααα α»ααααααΆααααΆαααΆαααααΌαααααΏαααΏααααΆααααααΆαααΆααααα»αα αααααΉαααΆαααααααααααααΆααααΆαααα αααα’ααΆαα αααααΆαα αααααΆαα ααΆαααααααααααααααα»αααΈαα ααααΎαα 3850 ααααΆαα ααα 10G αααα’αΆα ααααΎααΆααα αααααααααα αααααα‘αΎαα§ααααααααααΆαααααα’ααααα ααααΏα 10G α
α αΆααααΆααααΈαααααααα·αααΆαααααααααΆαααααααΆααα·αααα·ααα ααΎαααΉααααα·ααααα»ααα·ααααΆααΆα ααΆαα·αααα αΆααααΆααααΈαααααΊααΆαα·ααΈααααα’αα½αααΎααααΈααΆαααααααααΆαα αααΆαααΎααΆααα·ααααΆαααΈαααααααααααααΆααααΆαα»α αααααΆαα ααΆααααααααααΈαα½αα (αααΆαααΈαααααα ααααα ααΌαααααΆααα·ααααααααα) ααααα·αααααα optimal ααααΌαααΆαααααΎαααα»αααααΈααΆαααααα»αααΆα α αΎαααααα·αααΆα’αααΈαααααΉαααΎαα‘αΎααα ααΎαααααΌαααααΆαα αΆααααααΎαααααααα
ααΎαααΈααα αα·αααα·αααΆαα’αααααααααααααΆα αααΎαααααααα’αΆα ααΆααααααααααααααΆααααΎαα ααΆαα’ααα±αα ααααααα α»α VM αααααΆααααΉαααΆααααΆααααααααααΆαααΈααααααααααΉα ααΆαααααΆααααααΌαααααΆαααααΆαααααΆααα ααααααααααααΉααααααΆααααΆαααααΆααααααα½ααα ααΆαα ααα αΆαααΆααααα»αααααα α¬αααααααααααααααα·αααΆαααααΆααα αααααααα
αααααΆαααααααααΉααααααΆααα·αααααα ααααΆα ααΆαααΆαααααααΆααααα»α VMware vSphere αααα’αΆα
ααααΆαααααααααα αΆαααααααα½αααΆ ααα»ααααα
αΆααααΆααααΈαααααα·ααΈααΆαα½αααΈ VMware ααααΌαααΆαααααααΆααααΆαααααΆααααααΆαααααα "ααα" ααααααΆ ααΎαααΉαααααΎααααΆαααααααα·ααΈα₯ααα·ααααααααααΆααααΆαααααααααααα·αααα·ααα·αααα·α -
αααααα·ααΈ α’αΌα α αΆαααΆα αααΎααααΈαααα αΌαααααΆααΌαααΆαα»α αααααΆαα ααΆααααααααααΆααα’ααα αΌααα αααα»ααααα½α ααΎααααΈα’αΆα ααααΎαααΆααααΆαααΆααααα½αααΆαα½ααααΆαααΈααα·αααα·ααααααΆαααααα·αααααα - ααΆαααααααΊααΆααΌαααααΆααα·αααααα αααααα·ααΈαααααΆα ααααΌααααΈ αααΆαααΈααα αα»αααααΆα αααΆαααΈααααααααΆαααααααΌααααααα ααα» αα·αααΆααα·ααΆαααα αα·ααααααααα ααααΆαααααααΎαααΆαα
ααΎααααΈααααααααα ααααΈααααΆαααα ααΎαα’αΆα αααααΉααααα αΆαα’αααααααΆαααααα αααααΉααααα αΆααααα»αααΆαα’αα»ααααααΆαααααααα’αααΈααααααΆαααααααΆαα αααααΆαα ααΆαααααααααααααααΉα αα·αααΌα αααααααΆααααΌααααααα ααααΆαα
αααααΈα’ααααα
- αααααααΈ α‘ αααα»ααααα αααΆαααααααΆα oVirt 4.3 cluster α
- αααααααΈ α‘ ααΆαααα‘αΎα αα·αααααααα ααΆαααααααα oVirt 4.3 cluster α
- αααααααΈ α‘ ααΆαααα‘αΎαα ααααα VyOS αααα αααααΌαααΆααααα αααα’ααα±αααα α»αα
- αααααααΈ α‘ ααΆαααα‘αΎα Cisco 3850 stack αααα αααΆααααααΌαααΆαα’ααΈαααΊαααα
αααααααΈ 1. ααΆααααα αααΎααααΈααΆαααααααΆα oVirt 4.3 cluster
ααΆααααα ααααΆαααΈαααΌαααααΆα
ααΆαααα‘αΎα αα·αααααααα ααΆαααααααα OS ααΊααΆααα αΆαααΆααααα½ααααα»αα ααΆαα’αααααααΆα αααΎαα’αααΈααααααα‘αΎα αα·αααααααα ααΆαααααααα OS α±ααααΆαααααΉαααααΌα ααΌα ααααααααΆαα ααα»α ααΆαααα»αααΆαααααΆααΆααααααα’αααΈααααΆα ααα»αα’αααΈααΏααααααα
ααΌα αααα ααΎαααΆααααΆαααΈα Dell PowerEdge R640 α ααα½αααΈααααααΎαααααΌαααα‘αΎαααααααααααααα·ααααα·ααΆα αα·αα’αα»ααααααΆααααααααα ααΎααααΈααααΎαα½αααΆααΆα’ααααααα½ααα·αα·αααααααααααααΆααααααΎαααΆααααΆαααΈααα·αααα·ααα αααα»αα ααααα oVirt 4.3 α
αααααΆαααΎαααΆαααααααααααΎααααΆαααααααα·ααΈ oVirt ααααα·αααΆαααααααααΆαα·ααααααααααα₯ααα·ααααα ααααααααααααα·ααααα·ααΆαααααΌαααΆαααααΎαααΎααααααΆααααΆαααααααΆααααΆαααΈα CentOS 7.7αααααΈααΆ OSes ααααααααα’αΆα ααααΌαααΆαααα‘αΎααα ααΎαααΆαααΈααααααΆαα oVirtα
- ααΆαααααΆαααΆαα·αααααα’ααααΎ RHEL αααα α
ααΆα
ααααΆαα oVirt ; - ααααααααααααα·ααααα·ααΆα Oracle Linux αααΌααααα
ααααΆα 2019
ααΆααααΌαααΆααααααααΆα α’αααΈααΆαααΆααααααΆαααΆααααα oVirt αα ααΎααΆα
αα»ααααααα‘αΎα OS ααΆααααΌαααΆαααααΆαα
- ααααααα ααΆααααααααα ααα»α αααααΆαααααααΆα iDRAC αα ααΎαααΆαααΈαααΆααααΈαα
- ααααΎαα αα α»ααααααααΆααααααα·ααΈαααααα BIOS αα·α iDRAC αα ααααα α»αααααααααα»α;
- ααααααα ααΆαααααααααααααααααααααααααααααΆαααΈααα αα·αααα αααα»αααααααααα·ααααα·ααΆαα
- ααααααα ααΆαααααααα RAID ααΈααΆαααΌαααααΆα (RAID1 ααααΌαααΆαααααΆα) ααΎααααΈααα‘αΎαααααααααααααα·ααααα·ααΆααα ααΎαααΆαααΈαααα
αααααΆααααααΎαααα‘αΎαααααααααααααα·ααααα·ααΆααα ααΎααΆααααααΆααααααΎααα»αααΆαααα iDRAC - ααααΎαααΆαααα‘αΎαααΊααααααΆ αα·αααΆαααααα·ααααα αααα»αααΆααα ααΆαα αΌαααααΎαα»αααΌααααΆαααΈααα ααΎααααΈα αΆααααααΎαααΆαααα‘αΎαααααααααααααα·ααααα·ααΆαααα’αΆα ααα½αααΆαααΆαααα iDRAC αααααΈααΆααααΆαα’αααΈααΆααΆααα’αααααΈααΆαααααΆαααααΌααΈααα ααααΆαα α»α αα·αααααα»ααααααααΆαααα αααΆαααΈααα αα·αααα‘αΎαααααααααααααα·ααααα·ααΆαααΈααααΆααααααααΊαααααα
αααααΆααααΈααα‘αΎα OS ααΎαα’αα»ααααααΆααααααααααΌαααααααΆα
systemctl enable network.service
systemctl start network.service
systemctl status network.service
systemctl stop NetworkManager
systemctl disable NetworkManager
systemctl status NetworkManager
yum install -y ntp
systemctl enable ntpd.service
systemctl start ntpd.service
cat /etc/sysconfig/selinux
SELINUX=disabled
SELINUXTYPE=targeted
cat /etc/security/limits.conf
* soft nofile 65536
* hard nofile 65536
cat /etc/sysctl.conf
vm.max_map_count = 262144
vm.swappiness = 1
ααΆαααα‘αΎααααααα·ααΈααΌαααααΆα
ααΎααααΈααααααα ααΆαααααααα OS ααααΌαα’αααααααΌαααααααα ααΆααααααααα ααα»α αααααΆαααααααΆαααΆαα½ααα ααΎαααΆαααΈααα ααΌα ααααα’αααα’αΆα α αΌαααααΎα’ααΈαααΊαα·αααΎααααΈααααΎαα αα α»ααααααααΆα OS αα·αααα‘αΎααααα αααααααα·ααΈα αΆαααΆα αα αααα’αΆα ααααΌαααΆαααααΎααΆαααααα»αα’αα‘α»ααααααααΎαααΆαααα‘αΎα OS αα·ααααααΆααααΈααΆα
yum -y install epel-release
yum update
yum -y install bind-utils yum-utils net-tools git htop iotop nmon pciutils sysfsutils sysstat mc nc rsync wget traceroute gzip unzip telnet
ααΆααααΆααααααααΆαααΎ αα·ααααα»ααααααα·ααΈααΊααΆαααα αΆααα αααΌαα α·αααααααΆαααααα½α α αΎααα»ααααααααΆααααααΆααΆαααααΆαααα»αααααα
αααααΆαααα αΆααααααααααααΎαααΉαααΎααα½ααΆα’ααααααα½ααα·αα·αααααααα ααΎαααΉαααΎαααααΎαααΆαααααααααααα·ααααα·ααΆααααααααΌαααΆαα
systemctl enable tuned
systemctl start tuned
systemctl status tuned
tuned-adm profile
tuned-adm profile virtual-host
α’αααα’αΆα
α’αΆαααααααα’αααΈααααααααααα·ααααα·ααΆααα
ααΈαααα "
αααααΆααααΈααα‘αΎαααααααααααααα·ααααα·ααΆααα½α ααΎααααααα ααααααααααΆαα - ααα‘αΎαα ααα»α αααααΆαααααααΆααα ααΎαααΆαααΈα αα·αααααααα»αααΆαα Cisco 2960X α
ααΆαααααααα ααΆαααααααα Cisco 2960X Switch Stack
ααααααααααααΎαααΉαααααΎααααΆααα ααα½α VLANs ααΆαααααα - α¬αααααααΆα ααΆα ααααα‘ααααΈααααΆαα αα·ααα αα ααΎααααΈααααααααααααααααααααΆααα ααΆα αααα
VLAN α€ - α’ααΈαααΊαα·α
VLAN α€ - ααΆαααααααααα (iDRAC, αααααααααααα»α, ααΆααααααααααααααΌα)
VLAN α€ - αααααΆαααα·ααααα VM
VLAN α€ - αααααΆααααααΆααααααΆ (αα
α’αααααα
ααΆαααΆααααα
)
VLAN α€ - αααααΆαααΆααααα VM
VLAN α€ - αααααΆαα’αααα’αα·αααααα VM
VLAN α€ - αααααΆααααα½ααα·αα·ααα
αα»ααααα αΆααααααΎαααΆαααΆα αααααΊααΆααααΆααααΆααα ααααα·α L2 αααααΎααα½ααααα αααα
αααααΆααα’αααααααααααααΆααααααΆαααΈα oVirt αα·ααααΆαααΈααα·αααα·αααΆαα½αααααΆ ααααΌα ααΆαααααΆααααΆαααααααααααααααααααααα»αααααααΎα α αΆαααΆα αααααΌαααααααα ααΆαααααααααα»αααΆαα Cisco 2960X αα½αα
αααΆαααΈα Dell ααΆαααΆααααααΆα 4-port αααααααΆααααααΆαα½α ααΌα ααααα αΎα αα½ααααααα αααΆαααααΆαααααααα½ααααα Cisco 2960X αααααααΎααΆαααααΆαααααααΆααααα’ααα±αα ααααααα α»α αααααααΎααΆαααΆααααΆαααα»αααα ααααααααΆαααΌαααααα αΌααα αααα»αα ααα»α αααααΆααα‘αΌααΈαα αα·ααα·ααΈααΆα LACP ( 802.3 ααΆαααααΆαααΆαα·ααααααα):
- α αααααΈαααααΌααα ααΎαααΆαααΈαααααΌαααΆαααααααα ααΆαααααααααααα»αααααααααΆαα αα·αααααΆαααα αα»αααΆαα 2960X - α ααα»α αααααΆααα‘αΌααΈαααααααΉαααααΌαααΆαααααααα ααΆαααααααα ααααΆα ααΆαα½αααΉαα’αΆααααααΆααααααΆααααΆαααααααααααααΆαααΈα ααΆααααα½ααα·αα·ααα ααΆαααααΆααααααααΆαα½ααααΆαααΈααααααααααα αααα»αα ααααα oVirt ααΆααααΉαααααΌαααΆαααααΎαααααΆααααΆαααααΎα αααΆααααα»αααααααααΆαααααααΆαααΈααα·αααα·αα
- α αααααΈαααΈααΈααα ααΎαααΆαααΈαααααααΌαααΆαααααααα ααΆαααααααααααα»αααααααααΆαα αα·αααααΆαααα 2960X - αα ααΎα ααα»α αααααΆααα‘αΌααΈααααααααααααΎ oVirt ααααΆαααΉαααααΌαααΆααααααΎαα‘αΎαααΆαααα’ααΆαα (αα αααα»α VLANs αααααααΌαααααΆ) ααααααΆαααΈααα·αααα·αααΉαααααΌαααΆαααααΆααα
- α ααααααααΆαααΆααααΈα, αα αααα»αα ααα»α αααααΆααα‘αΌααΈααααΌα ααααΆ, ααΉαααααα, i.e. α ααΆα αααααΎαα½αααΆα’αΆα ααααΌαααΆααααααΌααααα»ααααααααΆαααααΆαααα»ααααααα»αααααΆαα
- ααΆαααααααααααΆααα ααΎααααΆααα αααααααααΌαααααΌα ααααΆααΆαααααα»α ααΎααααααα’αΆααααααΆα IP α
ααΆαααα‘αΎαααααα»αααΆααααΌαααααΆα 2960X αα·αα αααααααααΆα
αα»αααΆααααααααΎαααααΌαααααΆααααΌαα
- rack ααΆααααα;
- ααααΆααααΆαααααααααα·αααααΈααααααααααααααααΌαααΆα α§ααΆα ααα CAB-STK-E-1M;
- ααααΆαααα ααΉαααΆαααααααααααααΆααα;
- ααΆαααααΆαααα ααααΆααΈαααΆαααΆαααααα’ααααααααααααααΆααααα ααααα»αααΌααααααΆααααΆαααααααα ααΆααααααααααααΌααααααα½αααα
ααΆαααααΆαα
αΆαααΆα
ααααααΆααααΆααααααΆααα
αααααΆααααΈαααα
ααααα αΆαααΆαααΎααΎαααααααα
ααΆαααααααααα»αααΆααα
α’ααααααααααΆααααααααΆααΈαα½αααα·αααΆαααααααααΌαααΆαααααααΆααα
αααα»ααααααααααααα’αααααααααα ααΎα
αΆαααΆα
α ααααααΆαααΆααα’ααα’αΆα
ααααΌαααΆαααααΎααααα―αααΆαααα
ααααα
ααααααΎαααΊααααααα
ααΆαααααααααα»αααΆααα±ααααΏαααΆααααα’αΆα
ααααΎαα
ααΆα α αΎαααααΆαααααΆαααΈα αα·αα
ααα»α
αααααΆαααααααααααααΆααααα»ααα
ααΆα
1) ααααΆαααα αα»αααΆαααα α αΌααα ααΆαααααααααααΆααα·αααα· αααααΆααααα αΌααα ααΆααααααααααααα ααΆαααααααα α αΎαααααΎααΆααααααααΌαααααΆαα
ααΆαααααααα ααΆααααααααααααΌαααΌαααααΆαα
enable
configure terminal
hostname 2960X
no service pad
service timestamps debug datetime msec
service timestamps log datetime localtime show-timezone msec
no service password-encryption
service sequence-numbers
switch 1 priority 15
switch 2 priority 14
stack-mac persistent timer 0
clock timezone MSK 3
vtp mode transparent
ip subnet-zero
vlan 17
name Management
vlan 32
name PROD
vlan 33
name Interconnect
vlan 34
name Test
vlan 35
name Dev
vlan 40
name Monitoring
spanning-tree mode rapid-pvst
spanning-tree etherchannel guard misconfig
spanning-tree portfast bpduguard default
spanning-tree extend system-id
spanning-tree vlan 1-40 root primary
spanning-tree loopguard default
vlan internal allocation policy ascending
port-channel load-balance src-dst-ip
errdisable recovery cause loopback
errdisable recovery cause bpduguard
errdisable recovery interval 60
line con 0
session-timeout 60
exec-timeout 60 0
logging synchronous
line vty 5 15
session-timeout 60
exec-timeout 60 0
logging synchronous
ip http server
ip http secure-server
no vstack
interface Vlan1
no ip address
shutdown
exit
ααΎααααααΆαα»αααΆαααααααααααααΎααΆααααααααΆ "wr mem" α αΎαα αΆααααααΎαααααα»αααΆααα‘αΎααα·ααααααααΎααΆααααααααΆ "αααα»αα‘αΎααα·αΒ» αα ααΎαα»αααΆαααα 1.
2) ααΎαααααααα ααΆααααααααα ααααααααΆααααα»αααΆαααα αααα»αααααα αΌαααααΎαα αααα»α VLAN 17 ααΎααααΈααααΆααα ααα»α αααααΆααααααααααααααααααααααααα»α αα·ααααΆαααΈααα iDRAC α
αααα αα ααααααααααααα
interface GigabitEthernet1/0/5
description iDRAC - host1
switchport access vlan 17
switchport mode access
spanning-tree portfast edge
interface GigabitEthernet1/0/6
description Storage1 - Cntr0/Eth0
switchport access vlan 17
switchport mode access
spanning-tree portfast edge
interface GigabitEthernet2/0/5
description iDRAC - host2
switchport access vlan 17
switchport mode access
spanning-tree portfast edge
interface GigabitEthernet2/0/6
description Storage1 β Cntr1/Eth0
switchport access vlan 17
switchport mode access
spanning-tree portfast edge
exit
3) αααααΆααααΈαααα»ααααα‘αΎααα·α ααΌααα·αα·αααααΎαααΆααΆααααΎαααΆαααααΉαααααΌαα
αα·αα·αααααΎααα»αααΆααααααααα
2960X#show switch stack-ring speed
Stack Ring Speed : 20G
Stack Ring Configuration: Full
Stack Ring Protocol : FlexStack
2960X#show switch stack-ports
Switch # Port 1 Port 2
-------- ------ ------
1 Ok Ok
2 Ok Ok
2960X#show switch neighbors
Switch # Port 1 Port 2
-------- ------ ------
1 2 2
2 1 1
2960X#show switch detail
Switch/Stack Mac Address : 0cd0.f8e4.Π₯Π₯Π₯Π₯
Mac persistency wait time: Indefinite
H/W Current
Switch# Role Mac Address Priority Version State
----------------------------------------------------------
*1 Master 0cd0.f8e4.Π₯Π₯Π₯Π₯ 15 4 Ready
2 Member 0029.c251.Π₯Π₯Π₯Π₯ 14 4 Ready
Stack Port Status Neighbors
Switch# Port 1 Port 2 Port 1 Port 2
--------------------------------------------------------
1 Ok Ok 2 2
2 Ok Ok 1 1
4) ααΆαααα‘αΎαααΆαα αΌαααααΎ SSH αα ααα 2960X
ααΎααααΈααααααααααααααΈα ααααΆαααΆαααα SSH ααΎαααΉαααααΎ IP 172.20.1.10 αααααΆαααααααα ααΆαααααααααααααΆαα SVI (ααααΌαα ααα»α αααααΆαααα·αααα·α) VLAN17.
αααααΈααΆααΆααααΌαααΆαααααΆαα±ααααααΎα ααααααα§αααα·αααΆααααΆαααα ααΎαα»αααΆαααααααΆααααααααααααααααααααααα αααααΆαααα αΆααα αααΌαα α·ααα αα·ααααααααΆαααααΆαααααα½αα
ααααααα ααΆααααααααααΆαα αΌαααααΎ SSH αα ααααααα»αααΆααα
ip default-gateway 172.20.1.2
interface vlan 17
ip address 172.20.1.10 255.255.255.0
hostname 2960X
ip domain-name hw.home-lab.ru
no ip domain-lookup
clock set 12:47:04 06 Dec 2019
crypto key generate rsa
ip ssh version 2
ip ssh time-out 90
line vty 0 4
session-timeout 60
exec-timeout 60 0
privilege level 15
logging synchronous
transport input ssh
line vty 5 15
session-timeout 60
exec-timeout 60 0
privilege level 15
logging synchronous
transport input ssh
aaa new-model
aaa authentication login default local
username cisco privilege 15 secret my_ssh_password
ααα‘αΎαααΆααααααααΆααααΎααααΈα αΌααα»αααΆααααααΆααα·αααα·α
enable secret *myenablepassword*
service password-encryption
ααΆαααα‘αΎα NTP:
ntp server 85.21.78.8 prefer
ntp server 89.221.207.113
ntp server 185.22.60.71
ntp server 192.36.143.130
ntp server 185.209.85.222
show ntp status
show ntp associations
show clock detail
5) ααααααα ααΆααααααααα ααα»α αααααΆαα Etherchannel α‘αΌααΈαα αα·αα αααααΆαααΆααααααααΆαααα αααΆαααΈαα ααΎααααΈααΆαααΆααααα½αααααΆαααααααα ααΆαααααααα VLAN αααααΆαααΆααα’ααααΉαααααΌαααΆαααΎααα ααΎα ααα»α αααααΆααα‘αΌααΈααααΆααα’αα ααα»ααααααΆααΌαα ααΆααααΌαααΆαααααΆαα±ααααααααα ααΆααααααααααα’αααΈαααααααΌαααΆαααα»αααααα
ααααααα ααΆααααααααα ααα»α αααααΆαα Etherchannelα
interface Port-channel1
description EtherChannel with Host1-management
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
spanning-tree portfast edge trunk
interface Port-channel2
description EtherChannel with Host2-management
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
spanning-tree portfast edge trunk
interface Port-channel3
description EtherChannel with Host1-VM
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
spanning-tree portfast edge trunk
interface Port-channel4
description EtherChannel with Host2-VM
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
spanning-tree portfast edge trunk
interface GigabitEthernet1/0/1
description Host1-management
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
channel-protocol lacp
channel-group 1 mode active
interface GigabitEthernet1/0/2
description Host2-management
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
channel-protocol lacp
channel-group 2 mode active
interface GigabitEthernet1/0/3
description Host1-VM
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
channel-protocol lacp
channel-group 3 mode active
interface GigabitEthernet1/0/4
description Host2-VM
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
channel-protocol lacp
channel-group 4 mode active
interface GigabitEthernet2/0/1
description Host1-management
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
channel-protocol lacp
channel-group 1 mode active
interface GigabitEthernet2/0/2
description Host2-management
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
channel-protocol lacp
channel-group 2 mode active
interface GigabitEthernet2/0/3
description Host1-VM
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
channel-protocol lacp
channel-group 3 mode active
interface GigabitEthernet2/0/4
description Host2-VM
switchport trunk allowed vlan 10,17,30-40
switchport mode trunk
channel-protocol lacp
channel-group 4 mode active
ααΆαααααααα ααΆααααααααααααΌαααα ααα»α αααααΆαααααααΆααααααΆαααααΆαααΈααα·αααα·ααα ααΎαααΆαααΈα αααΆαααΈα 1 ΠΈ αααΆαααΈα 2
ααΎααα·αα·αααααΎαααααααΆααααααΌαα»ααααα αΆαααΆα ααααααΆααααΆαααααΆααααΎααααΈααααΎαααΆααα αααα»ααααααααα ααα‘αΎααααΌαα»ααααααΆαααααααααααααααΆαα
modinfo bonding
modinfo 8021q
yum install bridge-utils
ααΆαααααααα ααΆααααααααα ααα»α αααααΆααα‘αΌααΈαα BOND1 αααααΆαααααΆαααΈααα·αααα·α αα·αα ααα»α αααααΆααααΌαααααααααααΆαα ααΎαααΆαααΈαα
cat /etc/sysconfig/network-scripts/ifcfg-bond1
#DESCRIPTION - management
DEVICE=bond1
NAME=bond1
TYPE=Bond
IPV6INIT=no
ONBOOT=yes
USERCTL=no
NM_CONTROLLED=no
BOOTPROTO=none
BONDING_OPTS='mode=4 lacp_rate=1 xmit_hash_policy=2'
cat /etc/sysconfig/network-scripts/ifcfg-em2
#DESCRIPTION - management
DEVICE=em2
TYPE=Ethernet
BOOTPROTO=none
ONBOOT=yes
MASTER=bond1
SLAVE=yes
USERCTL=no
NM_CONTROLLED=no
cat /etc/sysconfig/network-scripts/ifcfg-em3
#DESCRIPTION - management
DEVICE=em3
TYPE=Ethernet
BOOTPROTO=none
ONBOOT=yes
MASTER=bond1
SLAVE=yes
USERCTL=no
NM_CONTROLLED=no
αααααΆααααΈαααα ααααΆαααααααα ααΎααα α‘α¦Π₯ αα·ααααΆαααΈα ααΎαα αΆααααααΎααααααΆαα‘αΎααα·ααα ααΎαααΆαααΈα α αΎααα·αα·αααααΎααα»αααΆαααα ααα»α αααααΆααα‘αΌααΈααα
- αα ααΎααα αΆααααααα
systemctl restart network
cat /proc/net/bonding/bond1
Ethernet Channel Bonding Driver: v3.7.1 (April 27, 2011)
Bonding Mode: IEEE 802.3ad Dynamic link aggregation
Transmit Hash Policy: layer2+3 (2)
MII Status: up
MII Polling Interval (ms): 100
Up Delay (ms): 0
Down Delay (ms): 0
...
802.3ad info
LACP rate: fast
Min links: 0
Aggregator selection policy (ad_select): stable
System priority: 65535
...
Slave Interface: em2
MII Status: up
Speed: 1000 Mbps
Duplex: full
...
Slave Interface: em3
MII Status: up
Speed: 1000 Mbps
Duplex: full
- αα ααΎααααα»αααΆαα α‘α¦Π₯:
2960X#show lacp internal
Flags: S - Device is requesting Slow LACPDUs
F - Device is requesting Fast LACPDUs
A - Device is in Active mode P - Device is in Passive mode
Channel group 1
LACP port Admin Oper Port Port
Port Flags State Priority Key Key Number State
Gi1/0/1 SA bndl 32768 0x1 0x1 0x102 0x3D
Gi2/0/1 SA bndl 32768 0x1 0x1 0x202 0x3D
2960X#sh etherchannel summary
Flags: D - down P - bundled in port-channel
I - stand-alone s - suspended
H - Hot-standby (LACP only)
R - Layer3 S - Layer2
U - in use N - not in use, no aggregation
f - failed to allocate aggregator
M - not in use, minimum links not met
m - not in use, port not aggregated due to minimum links not met
u - unsuitable for bundling
w - waiting to be aggregated
d - default port
A - formed by Auto LAG
Number of channel-groups in use: 11
Number of aggregators: 11
Group Port-channel Protocol Ports
------+-------------+-----------+-----------------------------------------------
1 Po1(SU) LACP Gi1/0/1(P) Gi2/0/1(P)
ααΆαααααααα ααΆααααααααααααΌαααα ααα»α αααααΆαααααααΆααααααΆααααΆααααααααααααααΆαα ααααααα ααΎαααΆαααΈα αααΆαααΈα 1 ΠΈ αααΆαααΈα 2
ααΆαααααααα ααΆααααααααα ααα»α αααααΆααα‘αΌααΈαα BOND1 αααααΆααααΆαααααααααα αα·αα ααα»α αααααΆααααΌαααααααααααΆαα ααΎαααΆαααΈαα
cat /etc/sysconfig/network-scripts/ifcfg-bond0
#DESCRIPTION - management
DEVICE=bond0
NAME=bond0
TYPE=Bond
BONDING_MASTER=yes
IPV6INIT=no
ONBOOT=yes
USERCTL=no
NM_CONTROLLED=no
BOOTPROTO=none
BONDING_OPTS='mode=4 lacp_rate=1 xmit_hash_policy=2'
cat /etc/sysconfig/network-scripts/ifcfg-em0
#DESCRIPTION - management
DEVICE=em0
TYPE=Ethernet
BOOTPROTO=none
ONBOOT=yes
MASTER=bond0
SLAVE=yes
USERCTL=no
NM_CONTROLLED=no
cat /etc/sysconfig/network-scripts/ifcfg-em1
#DESCRIPTION - management
DEVICE=em1
TYPE=Ethernet
BOOTPROTO=none
ONBOOT=yes
MASTER=bond0
SLAVE=yes
USERCTL=no
NM_CONTROLLED=no
αααααΆααααΈαααα ααααΆαααααααα ααΎααα α‘α¦Π₯ αα·ααααΆαααΈα ααΎαα αΆααααααΎααααααΆαα‘αΎααα·ααα ααΎαααΆαααΈα α αΎααα·αα·αααααΎααα»αααΆαααα ααα»α αααααΆααα‘αΌααΈααα
systemctl restart network
cat /proc/net/bonding/bond1
2960X#show lacp internal
2960X#sh etherchannel summary
ααΎαααααααα ααΆααααααααα ααα»α αααααΆαααααααΆαααααααααααα ααΎαααΆαααΈαααΈαα½αααα αααα»α VLAN α€α αΎαα αααΆαα α ααα»α αααααΆααα‘αΌααΈαα BOND1α
ααααααα ααΆαααααααα VLAN17 αα ααΎ Host1α
cat /etc/sysconfig/network-scripts/ifcfg-bond1.17
DEVICE=bond1.17
NAME=bond1-vlan17
BOOTPROTO=none
ONBOOT=yes
USERCTL=no
NM_CONTROLLED=no
VLAN=yes
MTU=1500
IPV4_FAILURE_FATAL=yes
IPV6INIT=no
IPADDR=172.20.17.163
NETMASK=255.255.255.0
GATEWAY=172.20.17.2
DEFROUTE=yes
DNS1=172.20.17.8
DNS2=172.20.17.9
ZONE=public
ααααααα ααΆαααααααα VLAN17 αα ααΎ Host2α
cat /etc/sysconfig/network-scripts/ifcfg-bond1.17
DEVICE=bond1.17
NAME=bond1-vlan17
BOOTPROTO=none
ONBOOT=yes
USERCTL=no
NM_CONTROLLED=no
VLAN=yes
MTU=1500
IPV4_FAILURE_FATAL=yes
IPV6INIT=no
IPADDR=172.20.17.164
NETMASK=255.255.255.0
GATEWAY=172.20.17.2
DEFROUTE=yes
DNS1=172.20.17.8
DNS2=172.20.17.9
ZONE=public
ααΎαα αΆααααααΎααααααΆαα‘αΎααα·ααα ααΎαααΆαααΈα α αΎααα·αα·αααααΎαααΆαααΎαααΎααααααα½αααα ααααααααΆαα αα·ααα ααα
ααΆαααα ααααΆαααααααα ααΆααααααααααααααα»αααΆαα Cisco 2960X α αΎαααααα·αααΎα’αααΈαααααΌαααΆαααααΎααΆαααααΉαααααΌα αααα₯α‘αΌααααααΎαααΆαααΆααααααΆαααααααΆαααααΆαα»α αααααΆαα ααΆααααααααααΆααα’αααα ααααΆαα αα·ααα αααα ααααα·α L2 α
ααΆαααα‘αΎααααααααααααα»α Dell MD3820f
αα»ααααα αΆααααααΎαααΆαααΆαααΎααΆαααα‘αΎααααααααααααα»α ααΆααααΌαααααααΆαααα ααααααα»αααΆαααααΈααααΌαα½α α αΎα α‘α¦Π₯ αααααααααα ααα»α αααααΆαα ααααΌα ααΆαααΆαααΈα αααΆαααΈα 1 ΠΈ αααΆαααΈα 2 ααΆαααα FC α
ααααΆααααΆαααΌαα ααααααααααααααααααααα»ααα½αααααΌαααΆαααααΆαααα ααααααα»αααΆααααααΌαααΆααααααα±αααα αααα»αααααΌααα»αα
ααααΆααααΆααααααΆααααααΆαααααααααααααα»αααΆαααα FC αα αααΆαααΈααα½αααααΎααα ααΌα αααα
αααα»αα’αα‘α»ααααααααΆααααααΆαα α’αααααααΌααααααα’αΆααααααΆα WWPN αααααΆαααααΆαααΈα FC HBA αααααααΆαααα α ααα FC αα ααΎαααααααααααα»α - ααΆααΉαα αΆαααΆα ααααααΆααααΆαααα‘αΎαααΆαααααΆαααααΆαααΈααα LUNs αα ααΎαααααααααααα»ααα ααααααααα
αα
ααΎααααΆααΈαααΆαααΆαααααα’αααααααααααα ααΌαααΆααα αα·αααα‘αΎαα§αααααααααΎααααΆαααααααΆααααααααααααααααααααααα»α Dell MD3820f β PowerVault Modular Disk Storage Manager (MDSM).
ααΎαααααΆαααα
ααΆααΆααααα’αΆααααααΆα IP ααααΆαααΎαααααααΆ α αΎααααααΆαααααααααα’αΆααααααΆαααααααΎαααΈ VLAN17ααΎααααΈαααααααααα§ααααααααααΆααΆαααα TCP/IPα
αααααααααα»ααα·αααααα α¦:
ControllerA IP - 172.20.1.13, MASK - 255.255.255.0, Gateway - 172.20.1.2
ControllerB IP - 172.20.1.14, MASK - 255.255.255.0, Gateway - 172.20.1.2
αααααΆααααΈαααα
αα’αΆαααααααΆα ααΌαα
αΌααα
ααΆααα
ααα»α
αααααΆαααααααααααααΆααααα»α α αΎααααααααΆααααααααΆαα ααααααααααααΆ ααααΎαα
αα
α»ααααααααΆααααααα·ααΈαααααααααααΆααα§ααααααααααΆ αα·αααΆα ααααα·αααΎα
αΆαααΆα
αααα
ααααααααααααααΌαααΆαααααΎααααΌαααΆααα·αααααΆαα
αααα»α
αααααΆααβααΈβαααα ααβααΆαβαααααβααΆαβααΎ ααΎαβααΉαβααααΌαβααααΎβααβααα»ααααΆαβααα αΆαβααα»αααααα
- ααααααα ααΆααααααααααααααααΆααα ααα FC αααααααΆαααΈα - αααΆαααΈααααααΆααα ααα.
- αααααΎααααα»αααα αΆαααααα - αααα»αααα αΆαααααα α αΎααααααααααΆαααΈα Dell ααααααΎαααΆααααΈααα ααΆα
- αααααΎααααα»αααΆα αα·αααΆααα·αααα·α (α¬ LUNs) αα αααα»αααΆαααααΉαααααΌαααΆααααα αΆαααααααΆαααΈαα
- ααααααα ααΆααααααααααΆααααα αΆαααααΆααα·αααα·α (α¬ LUNs) αααααΆαααααΆαααΈαα
ααΆααααααααααΆαααΈαααααΈ αα·αααΆαααααΆααα§ααααααααααα
ααα FC αααααααΆαααΈααα
αα½αααΆααΊααααΎα‘αΎαααΆαααααααΊαα»α - ααΆαααΌααααααΈαααΆαααΈα -> ααααα -> ααα
αΆααααααβ¦
α’αΆααααααΆα WWPN αααααΆαααΈα FC HBA α’αΆα
ααααΌαααΆαααααΎαα§ααΆα ααααα
αααα»ααααΆαααΈααα iDRAC α
ααΆαααααα ααΎααα½αααααα½αααΆαα’αααΈαα½αααΌα αααα
ααΆααααααααααα»αααααΈαααααΆαααΈα αα·αααΆαα
ααααΆαααΈααα
ααΆααααΌαααΆαααααΎααΆαααααααΊαα»α - ααΆαααΌααααααΈαααΆαααΈα -> ααααα -> αααα»αααα
αΆααααααβ¦
αααααΆαααααΆαααΈα ααΌαααααΎαααΎααααααα OS β ααΈαα»α
(DM-MP).
αααααΆααααΈαααααΎααααα»ααααΆαααΈα ααΆααααααααΆαα ααααΆαααααααα»α αα·αα αααααααααΎααααα»αααΆα - αααα»αααΆαααΆαα½αααΉαααααααα’αΆαααααααΎαααααΌαααΆααααααΆααααΆαα’ααα±αααα α»αα§ααΆα ααα RAID10 α αΎααα αααα»αααΆ ααΆααα·αααα·αααααα ααααααααΌαααΆαα
α αΎαα
α»αααααα ααααΆααααΆαα
α»ααααααααΊααΆααααα αΆαααααΆααα·αααα·α (α¬ LUNs) αα
ααΆαααααΆαααΈαα
ααΎααααΈααααΎααΌα
αααααΆαααααααΊαα»α - ααΆαααΌααααααΈαααΆαααΈα -> αααααΈααααα
αααα -> ααααααβ¦ ααΎαααααΆααααΆααα·αααα·αααΆαα½ααααΆαααΈαααααααααααααα
αα½αααα
α’αααΈααααααααΆααα½αααααΎααα ααΌα ααΌαααα’αααααααααα
αααααΆαααααααααααΎααααα
ααααΆαααα‘αΎααααααααααααα»α α αΎαααααα·αααΎα’αααΈαααααΌαααΆαααααΎααΆαααααΉαααααΌα αααααα
αΆαααααααα½αααααΎα LUNs αααα αΆαααααα½αααααΆαααα FC HBA αααααα½αααα
ααααααααα±ααααααααααααααΎαα
αα
α»ααααααααΆαααααααΆαα’αααΈααΆααααααΆααααααΆααα
ls -la /sys/class/scsi_host/
echo "- - -" > /sys/class/scsi_host/host[0-9]/scan
αααααΎαααΆααΎα§αααααα’αααΈαααααααα’αΆα ααΎαααΎααα ααΎαααΆαααΈαααααααααΎαα
cat /proc/scsi/scsi
Attached devices:
Host: scsi0 Channel: 02 Id: 00 Lun: 00
Vendor: DELL Model: PERC H330 Mini Rev: 4.29
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi15 Channel: 00 Id: 00 Lun: 00
Vendor: DELL Model: MD38xxf Rev: 0825
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi15 Channel: 00 Id: 00 Lun: 01
Vendor: DELL Model: MD38xxf Rev: 0825
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi15 Channel: 00 Id: 00 Lun: 04
Vendor: DELL Model: MD38xxf Rev: 0825
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi15 Channel: 00 Id: 00 Lun: 11
Vendor: DELL Model: MD38xxf Rev: 0825
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi15 Channel: 00 Id: 00 Lun: 31
Vendor: DELL Model: Universal Xport Rev: 0825
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi18 Channel: 00 Id: 00 Lun: 00
Vendor: DELL Model: MD38xxf Rev: 0825
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi18 Channel: 00 Id: 00 Lun: 01
Vendor: DELL Model: MD38xxf Rev: 0825
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi18 Channel: 00 Id: 00 Lun: 04
Vendor: DELL Model: MD38xxf Rev: 0825
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi18 Channel: 00 Id: 00 Lun: 11
Vendor: DELL Model: MD38xxf Rev: 0825
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi18 Channel: 00 Id: 00 Lun: 31
Vendor: DELL Model: Universal Xport Rev: 0825
Type: Direct-Access ANSI SCSI revision: 05
lsscsi
[0:2:0:0] disk DELL PERC H330 Mini 4.29 /dev/sda
[15:0:0:0] disk DELL MD38xxf 0825 -
[15:0:0:1] disk DELL MD38xxf 0825 /dev/sdb
[15:0:0:4] disk DELL MD38xxf 0825 /dev/sdc
[15:0:0:11] disk DELL MD38xxf 0825 /dev/sdd
[15:0:0:31] disk DELL Universal Xport 0825 -
[18:0:0:0] disk DELL MD38xxf 0825 -
[18:0:0:1] disk DELL MD38xxf 0825 /dev/sdi
[18:0:0:4] disk DELL MD38xxf 0825 /dev/sdj
[18:0:0:11] disk DELL MD38xxf 0825 /dev/sdk
[18:0:0:31] disk DELL Universal Xport 0825 -
αα ααΎαααΆαααΈα α’αααααα’αΆα ααααααα ααΆαααααααααααααααααααα αα»αα αΎααααααΈααΆαα αααααα‘αΎα oVirt ααΆα’αΆα ααααΎααΆααααααα½αα―αααΆαααααα ααΆααΆααΆααααααΎααααα»αααΆααααα½ααα·αα·αααααααα·ααααα·ααΆαααααΉαααααΌααααα MP ααΆαα»αααααααα½αα―αα
ααΆαααα‘αΎα αα·αααΆαααααααα ααΆαααααααα DM Multipath
yum install device-mapper-multipath
mpathconf --enable --user_friendly_names y
cat /etc/multipath.conf | egrep -v "^s*(#|$)"
defaults {
user_friendly_names yes
find_multipaths yes
}
blacklist {
wwid 26353900f02796769
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
devnode "^hd[a-z]"
}
αααααααααΆαααα MP α±ααα αΆααααααΎααααααααααααααααα· α αΎαααΎαααααΎαααΆαααΆα
systemctl enable multipathd && systemctl restart multipathd
αααα»ααα·αα·αααααΎαααααααΆαα’αααΈαααΌαα»ααααααΆααααα»ααααααΆααααααα·ααααα·ααΆα MPα
lsmod | grep dm_multipath
dm_multipath 27792 6 dm_service_time
dm_mod 124407 139 dm_multipath,dm_log,dm_mirror
modinfo dm_multipath
filename: /lib/modules/3.10.0-957.12.2.el7.x86_64/kernel/drivers/md/dm-multipath.ko.xz
license: GPL
author: Sistina Software <[email protected]>
description: device-mapper multipath target
retpoline: Y
rhelversion: 7.6
srcversion: 985A03DCAF053D4910E53EE
depends: dm-mod
intree: Y
vermagic: 3.10.0-957.12.2.el7.x86_64 SMP mod_unload modversions
signer: CentOS Linux kernel signing key
sig_key: A3:2D:39:46:F2:D3:58:EA:52:30:1F:63:37:8A:37:A5:54:03:00:45
sig_hashalgo: sha256
ααΌααααα‘ααααΎαααααααΆαααααααα’αααΈααΆαααααααα ααΆαααααααααα α»ααααΌααααααΆαααααΆααα
mpathconf
multipath is enabled
find_multipaths is disabled
user_friendly_names is disabled
dm_multipath module is loaded
multipathd is running
αααααΆααααΈαααααα LUN ααααΈαα αααα»ααααααααααααα»α αα·ααααα αΆαααΆααααααΆαααΈα α’αααααααΌαααααα HBAs αααααααΆαααα αααΆαααΈααα ααΎααΆα
systemctl reload multipathd
multipath -v2
α αΎαα α»αααααα ααΎααα·αα·αααααΎαααΆααΎ LUN ααΆααα’ααααααΌαααΆααααα αΆααα ααΎαααααααααααα»ααααααΆαααααΆαααΈα α αΎαααΆααΎααΆαααααΌαααΈααααααΆαααα½αααααΆααα’ααααααΆα¬α’ααα
αα·αα·αααααΎαααααα·ααααα·ααΆα MPα
multipath -ll
3600a098000e4b4b3000003175cec1840 dm-2 DELL ,MD38xxf
size=2.0T features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 rdac' wp=rw
|-+- policy='service-time 0' prio=14 status=active
| `- 15:0:0:1 sdb 8:16 active ready running
`-+- policy='service-time 0' prio=9 status=enabled
`- 18:0:0:1 sdi 8:128 active ready running
3600a098000e4b48f000002ab5cec1921 dm-6 DELL ,MD38xxf
size=10T features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 rdac' wp=rw
|-+- policy='service-time 0' prio=14 status=active
| `- 18:0:0:11 sdk 8:160 active ready running
`-+- policy='service-time 0' prio=9 status=enabled
`- 15:0:0:11 sdd 8:48 active ready running
3600a098000e4b4b3000003c95d171065 dm-3 DELL ,MD38xxf
size=150G features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 rdac' wp=rw
|-+- policy='service-time 0' prio=14 status=active
| `- 15:0:0:4 sdc 8:32 active ready running
`-+- policy='service-time 0' prio=9 status=enabled
`- 18:0:0:4 sdj 8:144 active ready running
ααΌα αααα’αααα’αΆα ααΎα ααΆααα·αααα·αααΆααααΈαα ααΎαααααααααααα»ααα·ααααααα’αΆα ααΎαααΎααα ααΆαααααααααααΌαααΈαα ααΌα ααααααΆαααΆααααα αααΆααα’ααααααΌαααΆααααα αα αααααΆααααααΆα’αααα’αΆα αααααα αααααααααΆαα - ααΆαααα‘αΎα oVirt cluster αααααΉαααααΌαααΆααα·ααΆααααΆαα αααα»αα’ααααααααααΆααα
ααααα: www.habr.com