{"id":30017,"date":"2019-10-31T21:33:15","date_gmt":"2019-10-31T18:33:15","guid":{"rendered":"https:\/\/prohoster.info\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-4-nastrojka-marshrutizatsii\/"},"modified":"2019-10-31T21:33:15","modified_gmt":"2019-10-31T18:33:15","slug":"vmware-nsx-dlya-samyh-malenkih-chast-4-nastrojka-marshrutizatsii","status":"publish","type":"post","link":"https:\/\/prohoster.info\/nl\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-4-nastrojka-marshrutizatsii","title":{"rendered":"VMware NSX voor de kleinsten. Deel 4. Routering configureren","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/971191806c6f8527adf5a5311ba73ed0.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/dataline\/blog\/432980\/\">Deel \u00e9\u00e9n. Inleiding<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/dataline\/blog\/441026\/\">Deel twee. Instellen van Firewall- en NAT-regels<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/dataline\/blog\/441882\/\">Deel drie. DHCP-configuratie<\/a><\/noindex><\/p>\n<p>NSX Edge ondersteunt statische en dynamische (OSPF, BGP) routering.<\/p>\n<blockquote><p><noindex><a rel=\"nofollow\" href=\"#Intro\">Initi\u00eble configuratie<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"#Static\">Statische routering<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"#OSPF\">OSPF<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"#BGP\">BGP<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"#Redistr\">Route Redistribution<\/a><\/noindex>\n<\/p><\/blockquote>\n<p><noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nOm routering in te stellen, ga naar de sectie <b>Beheer<\/b> en klik op het virtuele datacenter. Kies in het horizontale menu het tabblad <b>Edge Gateways<\/b>. Klik met de rechtermuisknop op het gewenste netwerk en kies de optie <b>Edge Gateway Services<\/b>. <br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/b73c554f4f5b9ea3024bb890a520a1c2.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nGa naar het menu Routering.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/76a5202920f5457a9085be386f042fda.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<noindex><a rel=\"nofollow\" name=\"Intro\"><\/a><\/noindex><\/p>\n<h3>Initi\u00eble configuratie (Routering Configuratie)<\/h3>\n<p>\nIn dit tabblad kunt u:<br \/>\n \u2014 de ECMP-optie inschakelen, waarmee tot 8 gelijke routes in de RIB kunnen worden ingesteld.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/85cddecd4777268b927b75afadf06654.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n \u2014 de default route wijzigen of uitschakelen.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/82b96952b79dc3b6d5a538878d4eb4ec.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n \u2014 de Router-ID selecteren. Als Router-ID kan het IP-adres van de externe interface worden gekozen. Zonder een Router-ID kan het OSPF- of BGP-proces niet worden gestart.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/7408588a7e4d1dcb0df1c62030b7164b.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nOf uw eigen toevoegen door op + te klikken.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/4f6e46cda6d1f36e5c08638222b9f739.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/cb3db6fe9e0b37f41672aba22245463c.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nConfiguratie opslaan.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/333d260d9340e7958a19bad306e74ebe.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nKlaar.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/4be439727326b0b515052fcd1c02d70b.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<noindex><a rel=\"nofollow\" name=\"Static\"><\/a><\/noindex><\/p>\n<h3>Instellen van statische routering<\/h3>\n<p>\nGa naar het tabblad Statische routering en klik op +.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/317d7a92e8201777278b20c912b5f29a.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nOm een statische route toe te voegen, vul de volgende verplichte velden in:<br \/>\n \u2014 Netwerk \u2013 doelnetwerk;<br \/>\n \u2014 Volgende Hop \u2013 IP-adressen van de host\/router waar het verkeer naar het doelnetwerk doorheen zal gaan;<br \/>\n \u2014 Interface \u2013 de interface achter welke de benodigde Volgende Hop zich bevindt. <br \/>\nKlik op Bewaren.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/173464a63b8647f1ae3c76ec1111e595.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nConfiguratie opslaan.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/06fd6df16ce76e5d89c956a775ebd3e7.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nKlaar.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/2b062aca1a54f2265eb69c03ef8bceaa.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<noindex><a rel=\"nofollow\" name=\"OSPF\"><\/a><\/noindex><\/p>\n<h3>Instellen van OSPF<\/h3>\n<p>\nGa naar het tabblad OSPF. We schakelen het OSPF-proces in. <br \/>\nIndien nodig, schakelen we Graceful restart uit, wat standaard is ingeschakeld. Graceful restart is een protocol dat het mogelijk maakt om verkeer door te sturen tijdens het convergentieproces van het control plane.<br \/>\nHier kunt u ook de optie voor het aankondigen van de standaardroute inschakelen, als deze aanwezig is in de RIB \u2014 optie default originate. <br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/b246b84743f01da9ed8376656193aa75.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nVoeg vervolgens een Gebied toe. Standaard is Gebied 0 toegevoegd. NSX Edge ondersteunt 3 typen Gebieden: <br \/>\n \u2014 Backbone-gebied (gebied 0+Normaal);<br \/>\n \u2014 Standaardgebied (Normaal);<br \/>\n \u2014 Not-so-stubby gebied (NSSA).<\/p>\n<p>Klik op + in het veld Gebiedsdefinitie om een nieuw Gebied toe te voegen.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/26574d9ec1580054b342a18becf9e144.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nGeef in het venster dat verschijnt de volgende verplichte velden op:<br \/>\n \u2014 Gebied ID;<br \/>\n \u2014 Gebiedstype.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/24dc9dbec1a4ed440fad33083b8dbd6e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIndien nodig, stel de authenticatie in. NSX Edge ondersteunt twee typen authenticatie: clear text (wachtwoord) en MD5.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/5730fafeef741cafcad6a9328c6fcb63.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nKlik op Bewaren.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/b4760d461ec2d27f4ca01a65c5629f40.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nConfiguratie opslaan.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/877310e77bcedaf6086f86e14819d71c.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nVoeg nu de interfaces toe waarop de OSPF-buurtschap vastgelegd zal worden. Klik daarvoor op + in het veld Interface Mapping.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/54ae3fbbbcb2e113e53b163f57d61a86.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nGeef in het venster dat verschijnt de volgende parameters op:<br \/>\n \u2014 Interface \u2013 de interface die zal worden gebruikt in het OSPF-proces;<br \/>\n \u2014 Gebied ID;<br \/>\n \u2014 Hello\/Dead interval \u2013 de protocollTimers;<br \/>\n \u2014 Prioriteit \u2013 de prioriteit die nodig is om DR\/BDR te kiezen;<br \/>\n \u2014 Kosten \u2013 een metriek die nodig is om de beste route te berekenen. Klik op Keep.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/3d2ca2a51950788434c07f3fdce58760.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/8fddf01464e0cda6647c3e2c3d64e5ad.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nLaten we onze router NSSA Area toevoegen. <br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/29230d1b25ac2aa0044f178c1a5162c9.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/f0b8a413fae822a2917fcdd6c5cee956.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nConfiguratie opslaan.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/bcb62eb346fb9c7491a3030fd825fcb2.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nOp de screenshot hieronder zien we:<br \/>\n1. ingestelde sessies;<br \/>\n2. ingestelde routes in RIB.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/efdbbf0caa8964873d2822dc94b7864b.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<noindex><a rel=\"nofollow\" name=\"BGP\"><\/a><\/noindex><\/p>\n<h3>BGP-configuratie<\/h3>\n<p>\nGa naar het tabblad BGP.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/0900982aa4ecf9461c3b23a7c17529d6.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nWe schakelen het BGP-proces in.<br \/>\nAls nodig, schakelen we Graceful Restart uit, dat standaard is ingeschakeld. Hier kan ook de optie Default Originate geactiveerd worden, zelfs als deze niet in RIB staat.<br \/>\nGeef AS van onze NSX Edge op. Ondersteuning voor 4-byte AS is alleen beschikbaar vanaf NSX versie 6.3.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/9b05df1ae9b6cd1b8fd5f82f1d05618c.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nOm peer Neighbors toe te voegen, klik op +.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/40c264bc8e67cbc9cd66e4a3ce099c81.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nGeef in het venster dat verschijnt de volgende parameters op:<br \/>\n \u2014 IP-adres \u2013 het BGP-paar adres;<br \/>\n \u2014 Remote AS \u2013 het AS-nummer van het BGP-paar;<br \/>\n \u2014 Gewicht \u2013 een metriek waarmee je de uitgaande traffic kunt beheren;<br \/>\n \u2014 Keep Alive\/Hold Down Tijd \u2013 protocoltimers.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/cce40bd51fe3091707733027d228dc1b.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nVervolgens configureren we BGP-filters. Voor eBGP-sessies worden standaard alle geadverteerde en geaccepteerde prefixen op deze router gefilterd, behalve de default route. Deze wordt geadverteerd met de optie default originate.<br \/>\nKlik op + om een BGP-filter toe te voegen. <br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/15a64f120eb5430a7ec9c8e45d75e15f.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nWe configureren de filter voor de uitgaande update.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/3972181e0c5e0c37af17739028f86083.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nWe configureren de filter voor de inkomende update.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/ff8021287fd647d0ea1f53f63a003142.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nKlik op Keep om de configuratie te voltooien.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/6f78c28c35e0f0974d1bbd76235dcc59.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nSla de configuratie op.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/6ebe1b4f95633801903e8d9a613bac83.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nKlaar.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/b89dfa150a756080f36c08247925cd8c.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nOp de screenshot hieronder zien we: <br \/>\n1. de ingestelde sessie.<br \/>\n2. ontvangen prefixen (4 prefixen \/24) van het BGP-paar.<br \/>\n3. de advertentie van de default route. Prefix 172.20.0.0\/24 wordt niet geadverteerd, omdat deze niet aan BGP is toegevoegd.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/03242f905bbb2afe83f1fc7395c9427d.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<noindex><a rel=\"nofollow\" name=\"Redistr\"><\/a><\/noindex><\/p>\n<h3>Configuratie Route Redistribution<\/h3>\n<p>\nGa naar het tabblad Route Redistribution.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/b4b04a1b177e457a113ee3749818c22b.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nWe schakelen de import van routes voor het protocol (BGP of OSPF) in.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/e28c9f0243b34d323dafa13aecc6c291.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nOm een IP-prefix toe te voegen, klik op +.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/c80bbc6643292ce14a10695fb92f4127.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nGeef de naam van de IP-prefix en de prefix zelf op.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/88e1128b376fd3a5ac7d1c4460524d81.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/c322875f22b611e3547f26b3af175a3e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nLaten we de Route Distribution Table configureren. Klik op +.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/ff3180ba3ba3fb4cbc86021f1376a0a5.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n \u2014 Prefix naam \u2013 kies de prefix die we in het bijbehorende protocol willen importeren. <br \/>\n \u2014 Learner Protocol \u2013 het protocol waarin we de prefix willen importeren;<br \/>\n \u2014 Toestaan leren \u2013 het protocol waaruit we de prefix exporteren;<br \/>\n \u2014 Actie \u2013 de handeling die op deze prefix zal worden toegepast.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/29eca54f33dff59c6c6aea7f2872826b.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nConfiguratie opslaan.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/81b29ae4f258af3a54ae870f051237b9.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nKlaar.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/17d6c6e764efd21e1d5ca2078242a147.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nOp de screenshot hieronder is te zien dat de overeenkomstige advertentie in BGP is verschenen.<br \/>\n<img decoding=\"async\" alt=\"VMware NSX voor de kleinsten. Deel 4. Routering configureren\" src=\"\/wp-content\/uploads\/2019\/03\/a9d718827027c67a130461c4c16fe38e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nDit is alles over routering met de NSX Edge. Vraag gerust als iets nog onduidelijk is. Volgende keer gaan we aan de slag met de load balancer.<br \/>\n<br \/>Bron: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/dataline\/blog\/444644\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0427\u0430\u0441\u0442\u044c \u043f\u0435\u0440\u0432\u0430\u044f. \u0412\u0432\u043e\u0434\u043d\u0430\u044f \u0427\u0430\u0441\u0442\u044c \u0432\u0442\u043e\u0440\u0430\u044f. \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u043f\u0440\u0430\u0432\u0438\u043b Firewall \u0438 NAT \u0427\u0430\u0441\u0442\u044c \u0442\u0440\u0435\u0442\u044c\u044f. \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 DHCP NSX Edge \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u0441\u0442\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0438 \u0434\u0438\u043d\u0430\u043c\u0438\u0447\u0435\u0441\u043a\u0443\u044e (ospf, bgp) \u043c\u0430\u0440\u0448\u0440\u0443\u0442\u0438\u0437\u0430\u0446\u0438\u044e. \u041f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u0430\u044f \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0421\u0442\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043c\u0430\u0440\u0448\u0440\u0443\u0442\u0438\u0437\u0430\u0446\u0438\u044f OSPF BGP Route Redistribution \u0427\u0442\u043e\u0431\u044b \u043d\u0430\u0441\u0442\u0440\u043e\u0438\u0442\u044c \u043c\u0430\u0440\u0448\u0440\u0443\u0442\u0438\u0437\u0430\u0446\u0438\u044e, \u0432 vCloud Director \u043f\u0435\u0440\u0435\u0439\u0434\u0438\u0442\u0435 \u0432 \u0440\u0430\u0437\u0434\u0435\u043b Administration \u0438 \u043a\u043b\u0438\u043a\u043d\u0438\u0442\u0435 \u043d\u0430 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u0434\u0430\u0442\u0430-\u0446\u0435\u043d\u0442\u0440. \u0412 \u0433\u043e\u0440\u0438\u0437\u043e\u043d\u0442\u0430\u043b\u044c\u043d\u043e\u043c \u043c\u0435\u043d\u044e \u0432\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u0432\u043a\u043b\u0430\u0434\u043a\u0443 Edge Gateways. \u041f\u0440\u0430\u0432\u043e\u0439 \u043a\u043d\u043e\u043f\u043a\u043e\u0439 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[],"tags":[],"class_list":["post-30017","post","type-post","status-publish","format-standard","hentry"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.3 - aioseo.com -->\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/nl\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-4-nastrojka-marshrutizatsii\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"nl_NL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47VMware NSX \u0434\u043b\u044f \u0441\u0430\u043c\u044b\u0445 \u043c\u0430\u043b\u0435\u043d\u044c\u043a\u0438\u0445. \u0427\u0430\u0441\u0442\u044c 4. \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u043c\u0430\u0440\u0448\u0440\u0443\u0442\u0438\u0437\u0430\u0446\u0438\u0438 | ProHoster\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/nl\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-4-nastrojka-marshrutizatsii\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T18:33:15+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T18:33:15+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47VMware NSX voor de kleintjes. Deel 4. Configuratie van routering | ProHoster","description":"","canonical_url":"https:\/\/prohoster.info\/nl\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-4-nastrojka-marshrutizatsii","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"nl_NL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47VMware NSX \u0434\u043b\u044f \u0441\u0430\u043c\u044b\u0445 \u043c\u0430\u043b\u0435\u043d\u044c\u043a\u0438\u0445. \u0427\u0430\u0441\u0442\u044c 4. \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u043c\u0430\u0440\u0448\u0440\u0443\u0442\u0438\u0437\u0430\u0446\u0438\u0438 | ProHoster","og:url":"https:\/\/prohoster.info\/nl\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-4-nastrojka-marshrutizatsii","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T18:33:15+00:00","article:modified_time":"2019-10-31T18:33:15+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"30017","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"Article","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-20 23:26:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 03:44:38","updated":"2026-01-20 23:26:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/nl\/wp-json\/wp\/v2\/posts\/30017","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/nl\/wp-json\/wp\/v2\/comments?post=30017"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/nl\/wp-json\/wp\/v2\/posts\/30017\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/nl\/wp-json\/wp\/v2\/media?parent=30017"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/nl\/wp-json\/wp\/v2\/categories?post=30017"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/nl\/wp-json\/wp\/v2\/tags?post=30017"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}