{"id":34884,"date":"2019-10-31T22:01:01","date_gmt":"2019-10-31T19:01:01","guid":{"rendered":"https:\/\/prohoster.info\/blog\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\/"},"modified":"2019-10-31T22:01:01","modified_gmt":"2019-10-31T19:01:01","slug":"upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","status":"publish","type":"post","link":"https:\/\/prohoster.info\/pl\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","title":{"rendered":"Rozbudowa systemu dyskowego starego serwera z szyn\u0105 PCIe 1.0 \u2014 2.0","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Rozbudowa systemu dyskowego starego serwera z szyn\u0105 PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/68025340a72b1acac62371764f328712.jpg\" style=\"display:block;margin: 0 auto;\" \/><b class=\"spoiler_title\">Dlaczego tematem tego artyku\u0142u jest modernizacja systemu dysk\u00f3w<\/b>Jasne jest, \u017ce na pocz\u0105tku nale\u017cy zwykle:<\/p>\n<ol>\n<li>Zwi\u0119kszy\u0107 pami\u0119\u0107 RAM. To tak oczywisty krok, \u017ce nawet nie uzna\u0142em za konieczne pisanie o tym w g\u0142\u00f3wnym artykule<\/li>\n<li>Zainstalowa\u0107 dodatkowy procesor(y) lub wymieni\u0107 obie jednostki na maksymalnie wydajne wersje obs\u0142ugiwane przez gniazda serwera.<\/li>\n<\/ol>\n<p>\nDla starych serwer\u00f3w pami\u0119\u0107 i procesory mo\u017cna zazwyczaj znale\u017a\u0107 w bardzo atrakcyjnych cenach.<\/p>\n<p>W pewnym momencie ka\u017cdy w\u0142a\u015bciciel w\u0142asnego serwera staje przed pytaniem \u2014 modernizacja czy nowy serwer.<\/p>\n<p>Poniewa\u017c cena nowego serwera mo\u017ce wynosi\u0107 miliony rubli, wiele os\u00f3b decyduje si\u0119 na modernizacj\u0119.<\/p>\n<p>Aby udana modernizacja by\u0142a mo\u017cliwa, bardzo wa\u017cne jest stosowanie kompromis\u00f3w, by za niewielk\u0105 op\u0142at\u0105 (w por\u00f3wnaniu do ceny nowego serwera) uzyska\u0107 znacz\u0105cy wzrost wydajno\u015bci.<\/p>\n<p>W artykule przedstawiono list\u0119 serwerowych SSD PCI-E 2.0 x8, kt\u00f3re obecnie mocno potania\u0142y, wskazano kontrolery RAID z obs\u0142ug\u0105 SSD caching oraz przetestowano SATA III SSD na interfejsie SATA II.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nNajbardziej oczywistym sposobem modernizacji systemu dyskowego jest przej\u015bcie z HDD na SSD. Dotyczy to zar\u00f3wno laptop\u00f3w, jak i serwer\u00f3w. W przypadku serwer\u00f3w r\u00f3\u017cnica polega g\u0142\u00f3wnie na tym, \u017ce SSD mo\u017cna \u0142atwo zorganizowa\u0107 w RAID.<\/p>\n<p>Jednak s\u0105 pewne subtelno\u015bci zwi\u0105zane z tym, \u017ce porty SATA III w starym serwerze mog\u0105 by\u0107 nieobecne, a wtedy trzeba b\u0119dzie wymieni\u0107 lub zainstalowa\u0107 odpowiedni kontroler.<\/p>\n<p>Oczywi\u015bcie istniej\u0105 tak\u017ce rozwi\u0105zania po\u015brednie.<\/p>\n<h2>Caching na SSD.<\/h2>\n<p>\nOg\u00f3lnie rzecz bior\u0105c, ten spos\u00f3b dobrze nadaje si\u0119 do baz danych, 1C, ka\u017cdego dost\u0119pu losowego. Rzeczywi\u015bcie przyspiesza pr\u0119dko\u015b\u0107. Dla ogromnych plik\u00f3w, monitoringu wideo, ten spos\u00f3b jest bezu\u017cyteczny.<\/p>\n<h3>Kontrolery RAID LSI (IBM, DELL, CISCO, Fujitsu)<\/h3>\n<p>\nOd serii 92xx LSI ma technologi\u0119 CacheCade 2.0, kt\u00f3ra pozwala na wykorzystanie niemal dowolnych SSD SATA jako cache dla tablicy RAID. Zar\u00f3wno do odczytu, jak i zapisu. A nawet na stworzenie lustra z pami\u0119ci cache SSD.<\/p>\n<p>Z kontrolerami markowymi sprawa jest bardziej skomplikowana. Dotyczy to szczeg\u00f3lnie IBM. Klucze i SSD dla CacheCade trzeba b\u0119dzie kupi\u0107 od IBM za ogromne pieni\u0105dze, wi\u0119c \u0142atwiej jest wymieni\u0107 kontroler na LSI i kupi\u0107 taniej klucz sprz\u0119towy. Klucze programowe s\u0105 znacznie dro\u017csze od sprz\u0119towych.<\/p>\n<h3>Kontrolery RAID Adaptec<\/h3>\n<p>\nKontrolery Adaptec maj\u0105 technologi\u0119 MaxCache, kt\u00f3ra r\u00f3wnie\u017c umo\u017cliwia wykorzystanie SSD jako pami\u0119ci podr\u0119cznej. Interesuj\u0105 nas wersje kontroler\u00f3w, kt\u00f3re ko\u0144cz\u0105 si\u0119 na liter\u0119 Q.<\/p>\n<p>Kontrolery Q mog\u0105 korzysta\u0107 z niemal ka\u017cdego SSD, a nie tylko z tych dostarczanych przez Adaptec.<\/p>\n<ul>\n<li>Od serii 5xxx wszystkie kontrolery maj\u0105 wsparcie dla hybrydowego RAID. Istot\u0105 tej technologii jest to, \u017ce odczyt zawsze odbywa si\u0119 z SSD, gdy jest lustrzany obraz jednego z dysk\u00f3w, na kt\u00f3rym znajduje si\u0119 SSD.<\/li>\n<li>5xxxQ, na przyk\u0142ad 5805ZQ. Te kontrolery wspieraj\u0105 MaxCache 1.0. Tylko pami\u0119\u0107 podr\u0119czna do odczytu.<\/li>\n<li>6xxQ, na przyk\u0142ad 6805Q. MaxCache 2.0. Pami\u0119\u0107 podr\u0119czna do odczytu i zapisu.<\/li>\n<li>7xxQ, na przyk\u0142ad 7805Q. MaxCache 3.0. Pami\u0119\u0107 podr\u0119czna do odczytu i zapisu.<\/li>\n<li>8xxQ praktycznie nie ma sensu u\u017cywa\u0107 do aktualizacji ze wzgl\u0119du na wysokie ceny.<\/li>\n<\/ul>\n<p>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/pc-administrator\/blog\/319214\/\">Artyku\u0142 o pami\u0119ci podr\u0119cznej na SSD na Habrze (kontrolery i systemy operacyjne).<\/a><\/noindex><\/p>\n<h3>Programowe technologie pami\u0119ci podr\u0119cznej na SSD<\/h3>\n<p>\nNie b\u0119d\u0119 omawia\u0107 tych technologii. Praktycznie w ka\u017cdym systemie operacyjnym s\u0105 one teraz wspierane. Zapami\u0119ta\u0142em, \u017ce przy u\u017cyciu btrfs, automatycznie przekierowuje zapytania odczytu do urz\u0105dzenia z najkr\u00f3tsz\u0105 kolejk\u0105 \u2014 SSD.<\/p>\n<h2>SATA III SSD na interfejsie SATA II<\/h2>\n<p>\nPoniewa\u017c nie zawsze jest mo\u017cliwo\u015b\u0107 i pieni\u0105dze na nowy kontroler, pojawia si\u0119 pytanie, jak dobrze SATA III SSD dzia\u0142aj\u0105 na przestarza\u0142ym interfejsie SATA II.<\/p>\n<p>Przeprowadzimy ma\u0142y test. Naszym obiektem testowym b\u0119dzie SATA III SSD Intel S3710 o pojemno\u015bci 400GB.<\/p>\n<p>Odczyt losowy, IOPS<br \/>\n\u015arednia latencja odczytu, ms<br \/>\nZapis losowy, IOPS<br \/>\n\u015arednia latencja zapisu, ms<br \/>\nOdczyt liniowy, MB\/s<br \/>\nZapis liniowy, MB\/s<\/p>\n<p>SATA II<br \/>\n21241<br \/>\n2<br \/>\n13580<br \/>\n4<br \/>\n282<br \/>\n235<\/p>\n<p>SATA III<br \/>\n68073<br \/>\n0.468<br \/>\n61392<br \/>\n0.52<br \/>\n514<br \/>\n462<\/p>\n<p>\n<b class=\"spoiler_title\">Polecenia u\u017cywane do testowania wydajno\u015bci<\/b><\/p>\n<pre><code class=\"bash\">fio --name LinRead --eta-newline=5s --filename=\/dev\/sda --rw=read --size=500m --io_size=10g --blocksize=1024k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=1 --runtime=60 --group_reporting \n\nfio --name LinWrite --eta-newline=5s --filename=\/dev\/sda --rw=write --size=500m --io_size=10g --blocksize=1024k --ioengine=libaio --fsync=10000 --iodepth=32 --direct=1 --numjobs=1 --runtime=60 --group_reporting\n\nfio --name RandRead --eta-newline=5s --filename=\/dev\/sda --rw=randread --size=500m --io_size=10g --blocksize=4k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=4 --runtime=60 --group_reporting\n\nfio --name RandWrite --eta-newline=5s --filename=\/dev\/sda --rw=randwrite --size=500m --io_size=10g --blocksize=4k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=4 --runtime=60 --group_reporting\n<\/code><\/pre>\n<p>Jak wida\u0107, r\u00f3\u017cnice w liniowej pr\u0119dko\u015bci, IOPS oraz latencjach s\u0105 do\u015b\u0107 znaczne, dlatego ma sens korzysta\u0107 tylko z interfejsu SATA III, a je\u015bli go nie ma, zainstalowa\u0107 kontroler.<\/p>\n<p>Dla sprawiedliwo\u015bci musz\u0119 powiedzie\u0107, \u017ce w innych eksperymentach <noindex><a rel=\"nofollow\" href=\"http:\/\/www.thg.ru\/storage\/ustanovka_ssd_v_sistemu_s_sata_3_gbits_test\/ustanovka_ssd_v_sistemu_s_sata_3_gbits_test-01.html\">innym eksperymentom<\/a><\/noindex> R\u00f3\u017cnica w szybko\u015bci losowego odczytu i zapisu by\u0142a nieznaczna. Mo\u017cliwe, \u017ce taka du\u017ca r\u00f3\u017cnica w IOPS mi\u0119dzy SATA II a SATA III wynika\u0142a z tego, \u017ce mia\u0142em jaki\u015b wyj\u0105tkowo nieudany kontroler SATA II lub sterownik z jakimi\u015b b\u0142\u0119dami.<\/p>\n<p>Jednak fakt jest taki, \u017ce nale\u017cy sprawdzi\u0107 pr\u0119dko\u015b\u0107 SATA II \u2014 mo\u017ce macie podobny wolny kontroler. W takim przypadku przej\u015bcie na kontroler SATA III jest konieczne.<\/p>\n<h2>SSD PCIe na magistrali PCI-e 2.0 lub 1.0<\/h2>\n<p>\nJak wiadomo, najszybsze SSD to PCI-e NVMe, kt\u00f3re nie s\u0105 ograniczone protoko\u0142ami SAS ani SATA.<\/p>\n<p>Jednak przy instalacji nowoczesnych SSD PCI-e nale\u017cy uwzgl\u0119dni\u0107 fakt, \u017ce wi\u0119kszo\u015b\u0107 z nich korzysta tylko z 4 linii PCI-e, zazwyczaj PCI-e 3.0 lub 3.1.<\/p>\n<p>A teraz sp\u00f3jrzmy na tabel\u0119 pr\u0119dko\u015bci magistrali PCI-e.<\/p>\n<p>Przepustowo\u015b\u0107 PCI Express, GB\/s<\/p>\n<p>Rok <br \/>\n wydania<\/p>\n<p>Wersja<br \/>\nPCI Express<\/p>\n<p>Kodowanie<\/p>\n<p>Szybko\u015b\u0107<br \/>\ntransmisje<\/p>\n<p>Przepustowo\u015b\u0107 na x linii<\/p>\n<p>\u00d74<br \/>\n\u00d78<br \/>\n\u00d716<\/p>\n<p>2002<br \/>\n1.0<br \/>\n8b\/10b<\/p>\n<p>0.50 GB\/s<br \/>\n1.0 GB\/s<br \/>\n2.0 GB\/s<br \/>\n4.0 GB\/s<\/p>\n<p>2007<br \/>\n2.0<br \/>\n8b\/10b<\/p>\n<p>1.0 GB\/s<br \/>\n2.0 GB\/s<br \/>\n4.0 GB\/s<br \/>\n8.0 GB\/s<\/p>\n<p>2010<br \/>\n3.0<br \/>\n128b\/130b<\/p>\n<p>1.97 GB\/s<br \/>\n3.94 GB\/s<br \/>\n7.88 GB\/s<br \/>\n15.8 GB\/s<\/p>\n<p>Przy instalacji SSD PCI 3.0 x4 w magistrali PCI-e 2.0 b\u0119dzie on dzia\u0142a\u0142 na takim samym poziomie, ale z znacznie mniejsz\u0105 pr\u0119dko\u015bci\u0105. Jest problem, \u017ce liniowe pr\u0119dko\u015bci nowoczesnych SSD PCI-e przekraczaj\u0105 przepustowo\u015b\u0107 magistrali PCI-e 2.0, a tym bardziej PCI-e 1.0.<\/p>\n<h3>M.2 SSD i przej\u015bci\u00f3wka PCI-e<\/h3>\n<p>S\u0105 niez\u0142e opcje modernizacji, gdy kupujemy za 10 dolar\u00f3w przej\u015bci\u00f3wk\u0119 i instalujemy M.2 SSD w serwerze, ale znowu, dla dobrych SSD b\u0119d\u0105 ograniczenia pr\u0119dko\u015bci (szczeg\u00f3lnie na PCI-e 1.0), a M.2 SSD nie zawsze s\u0105 gotowe do obci\u0105\u017ce\u0144 serwerowych: maj\u0105 du\u017c\u0105 odporno\u015b\u0107 na zu\u017cycie, ochron\u0119 przed zasilaniem i stabilno\u015b\u0107 parametr\u00f3w pr\u0119dko\u015bci z powodu zape\u0142nienia SLC cache w ta\u0144szych modelach.<\/p>\n<p>Wi\u0119c ta metoda mo\u017ce by\u0107 odpowiednia tylko dla serwera z magistral\u0105 PCI-e 2.0 i zaj\u0119tego mniej krytycznym zadaniem.<\/p>\n<h3>PCI-E 2.0 x8 SSD<\/h3>\n<p>\nNajbardziej ekonomiczn\u0105 modernizacj\u0105 jest u\u017cycie SSD PCI-E 2.0 x8 dla serwer\u00f3w z magistral\u0105 PCI-e 1.0 (przepustowo\u015b\u0107 do 2 GB\/s) oraz PCI-e 2.0 (do 4 GB\/s).<\/p>\n<p>Takie SSD do serwer\u00f3w mo\u017cna obecnie kupi\u0107 ca\u0142kiem tanio zar\u00f3wno na r\u00f3\u017cnych platformach zakupowych, jak i na aukcjach internetowych, w tym w Rosji.<\/p>\n<p>Sporz\u0105dzi\u0142em tabel\u0119 takich przestarza\u0142ych SSD, kt\u00f3re doskonale przyspiesz\u0105 tw\u00f3j stary serwer. Na ko\u0144cu tabeli doda\u0142em kilka SSD z interfejsem PCI-E 3.0 x8. Mo\u017ce uda ci si\u0119 je zdoby\u0107 w rozs\u0105dnej cenie.<\/p>\n<p>Nazwa<br \/>\nTB<br \/>\nPBW<br \/>\nPCI-E<br \/>\n4k odczyt iops, K<br \/>\n4k zapis iops, K<br \/>\nodczyt, MB\/s<br \/>\nzapis, MB\/s<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusionio_iodrive2_duo_mlc_application_accelerator_review\">Fusion-io ioDrive II DUO MLC<\/a><\/noindex><br \/>\n2.4<br \/>\n32.5<br \/>\n2.0 x8<br \/>\n480<br \/>\n490<br \/>\n3000<br \/>\n2500<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SANDISK FUSION IOMEMORY SX350-1300<\/a><\/noindex><br \/>\n1.3<br \/>\n4<br \/>\n2.0 x8<br \/>\n225<br \/>\n345<br \/>\n2800<br \/>\n1300<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_px600_review\">SANDISK FUSION IOMEMORY PX600-1300<\/a><\/noindex><br \/>\n1.3<br \/>\n16<br \/>\n2.0 x8<br \/>\n235<br \/>\n375<br \/>\n2700<br \/>\n1700<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SANDISK FUSION IOMEMORY SX350-1600<\/a><\/noindex><br \/>\n1.6<br \/>\n5.5<br \/>\n2.0 x8<br \/>\n270<br \/>\n375<br \/>\n2800<br \/>\n1700<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_sx300_review\">SanDisk Fusion ioMemory SX300-3200<\/a><\/noindex><br \/>\n3.2<br \/>\n11<br \/>\n2.0 x8<br \/>\n345<br \/>\n385<br \/>\n2700<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SanDisk Fusion ioMemory SX350-3200<\/a><\/noindex><br \/>\n3.2<br \/>\n11<br \/>\n2.0 x8<br \/>\n345<br \/>\n385<br \/>\n2800<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_px600_review\">SANDISK FUSION IOMEMORY PX600<\/a><\/noindex><br \/>\n2.6<br \/>\n32<br \/>\n2.0 x8<br \/>\n350<br \/>\n385<br \/>\n2700<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/support.huawei.com\/enterprise\/en\/doc\/EDOC1000052593?section=j005\">Huawei ES3000 V2<\/a><\/noindex><br \/>\n1,6<br \/>\n8,76<br \/>\n2.0 x8<br \/>\n395<br \/>\n270<br \/>\n1550<br \/>\n1100<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/support.huawei.com\/enterprise\/en\/doc\/EDOC1000052593?section=j005\">Huawei ES3000 V2<\/a><\/noindex><br \/>\n3,2<br \/>\n17,52<br \/>\n2.0 x8<br \/>\n770<br \/>\n230<br \/>\n3100<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.emc.com\/collateral\/data-sheet\/h11411-xtremsf-ds.pdf\">EMC XtremSF<\/a><\/noindex><br \/>\n2,2<br \/>\n\u00a0<br \/>\n2.0 x8<br \/>\n340<br \/>\n110<br \/>\n2700<br \/>\n1000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/virident_flashmax_ii_mlc_application_accelerator_review_22tb\">HGST Virident FlashMAX II<\/a><\/noindex><br \/>\n2,2<br \/>\n33<br \/>\n2.0 x8<br \/>\n350<br \/>\n103<br \/>\n2700<br \/>\n1000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/documents.westerndigital.com\/\/content\/dam\/doc-library\/en_us\/assets\/public\/western-digital\/product\/hgst\/general-docs\/data-sheet-flashmax-pcie.pdf\">HGST Virident SSD FlashMAX II<\/a><\/noindex><br \/>\n4,8<br \/>\n10.1<br \/>\n2.0 x8<br \/>\n269<br \/>\n51<br \/>\n2600<br \/>\n900<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/documents.westerndigital.com\/\/content\/dam\/doc-library\/en_us\/assets\/public\/western-digital\/product\/hgst\/general-docs\/data-sheet-flashmax-pcie.pdf\">HGST Virident FlashMAX III<\/a><\/noindex><br \/>\n2,2<br \/>\n7.1<br \/>\n2.0 x8<br \/>\n531<br \/>\n59<br \/>\n2700<br \/>\n1400<\/p>\n<p>Dell Micron P420M<br \/>\n1.4<br \/>\n9.2<br \/>\n2.0 x8<br \/>\n750<br \/>\n95<br \/>\n3300<br \/>\n630<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/micron_p420m_enterprise_pcie_ssd_review\">Micron P420M<\/a><\/noindex><br \/>\n1.4<br \/>\n9.2<br \/>\n2.0 x8<br \/>\n750<br \/>\n95<br \/>\n3300<br \/>\n630<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.anandtech.com\/show\/10890\/hgst-ultrastar-sn200-accelerator-768-tb-capacity-61-gbs-read-speed-12m-iops\">HGST SN260<\/a><\/noindex><br \/>\n1.6<br \/>\n25.10<br \/>\n3.0 x8<br \/>\n1200<br \/>\n200<br \/>\n6170<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.anandtech.com\/show\/10890\/hgst-ultrastar-sn200-accelerator-768-tb-capacity-61-gbs-read-speed-12m-iops\">HGST SN260<\/a><\/noindex><br \/>\n3,2<br \/>\n17,52<br \/>\n3.0 x8<br \/>\n1200<br \/>\n200<br \/>\n6170<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/ark.intel.com\/content\/www\/ru\/ru\/ark\/products\/88731\/intel-ssd-dc-p3608-series-1-6tb-1-2-height-pcie-3-0-x8-20nm-mlc.html\">Intel P3608<\/a><\/noindex><br \/>\n3,2<br \/>\n17,5<br \/>\n3.0 x8<br \/>\n850<br \/>\n80<br \/>\n4500<br \/>\n2600<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.kingston.com\/datasheets\/DCP1000_us.pdf\">Kingston DCP1000<\/a><\/noindex><br \/>\n3,2<br \/>\n2,78<br \/>\n3.0 x8<br \/>\n1000<br \/>\n180<br \/>\n6800<br \/>\n6000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/docs.oracle.com\/cd\/E65386_01\/html\/E65387\/gokdw.html#scrolltoc\">Oracle F320<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n750<br \/>\n120<br \/>\n5500<br \/>\n1800<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/global.semi.static\/PM1725_NVMe_PCIe_SSD_Samsung_2016-1.pdf\">Samsung PM1725<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n1000<br \/>\n120<br \/>\n6000<br \/>\n2000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/ssd\/enterprise-ssd\/MZPLL3T2HMLS\/\">Samsung PM1725a<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n1000<br \/>\n180<br \/>\n6200<br \/>\n2600<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/ssd\/enterprise-ssd\/MZPLL3T2HAJQ\/\">Samsung PM1725b<\/a><\/noindex><br \/>\n3.2<br \/>\n18<br \/>\n3.0 x8<br \/>\n980<br \/>\n180<br \/>\n6200<br \/>\n2600<\/p>\n<p>\n<img decoding=\"async\" alt=\"Rozbudowa systemu dyskowego starego serwera z szyn\u0105 PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/369c72c6f028b915a199e85fc3de3819.jpg\" style=\"display:block;margin: 0 auto;\" \/>W przypadku tych SSD szczeg\u00f3lnie wyr\u00f3\u017cniaj\u0105 si\u0119 Fusion ioMemory. Dyrektorem naukowym <noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/Fusion-io\">Fusion<\/a><\/noindex> zosta\u0142a <noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/%D0%92%D0%BE%D0%B7%D0%BD%D1%8F%D0%BA,_%D0%A1%D1%82%D0%B8%D0%B2\">Steve Wozniak<\/a><\/noindex>. Nast\u0119pnie firma ta zosta\u0142a zakupiona przez SanDisk za 1,2 miliarda dolar\u00f3w. W swoim czasie kosztowa\u0142y od 50 000 dolar\u00f3w za sztuk\u0119. Obecnie mo\u017cna je kupi\u0107 za kilka setek dolar\u00f3w w nowym stanie za dysk o pojemno\u015bci od 1 TB i wi\u0119cej.<\/p>\n<p>Je\u015bli przyjrze\u0107 si\u0119 tabeli, wida\u0107, \u017ce maj\u0105 do\u015b\u0107 wysok\u0105 liczb\u0119 IOPS zapisu prawie r\u00f3wn\u0105 liczbie IOPS odczytu. Bior\u0105c pod uwag\u0119 ich aktualn\u0105 cen\u0119, moim zdaniem warto zwr\u00f3ci\u0107 uwag\u0119 na te SSD. <\/p>\n<p>Prawda, maj\u0105 kilka szczeg\u00f3lnych cech:<\/p>\n<ol>\n<li>Nie mog\u0105 by\u0107 dyskami rozruchowymi<\/li>\n<li>Wymagaj\u0105 sterownika do u\u017cycia. Sterowniki s\u0105 praktycznie dost\u0119pne do wszystkiego, ale dla najnowszych wersji Linux trzeba je b\u0119dzie skompilowa\u0107.<\/li>\n<li>Optymalny rozmiar sektora wynosi 4096 bajt\u00f3w. (512 r\u00f3wnie\u017c jest obs\u0142ugiwany)<\/li>\n<li>Sterownik w najgorszym scenariuszu mo\u017ce zu\u017cywa\u0107 do\u015b\u0107 du\u017co RAM (przy rozmiarze sektora 512 bajt\u00f3w)<\/li>\n<li>Wydajno\u015b\u0107 zale\u017cy od szybko\u015bci procesora, dlatego lepiej wy\u0142\u0105czy\u0107 technologie oszcz\u0119dzania energii. To jest zar\u00f3wno plus, jak i minus, poniewa\u017c przy pot\u0119\u017cnym procesorze urz\u0105dzenie mo\u017ce dzia\u0142a\u0107 nawet szybciej, ni\u017c wskazuj\u0105 specyfikacje.<\/li>\n<li>Wymaga dobrego ch\u0142odzenia. Dla serwer\u00f3w nie powinno to by\u0107 problemem.<\/li>\n<li>Nie jest zalecane dla ESXi, poniewa\u017c ESXi preferuje dyski z sektorem 512N, a to mo\u017ce prowadzi\u0107 do du\u017cego zu\u017cycia pami\u0119ci przez sterownik.<\/li>\n<li>Markowe wersje tych SSD zazwyczaj nie s\u0105 wspierane przez dostawc\u00f3w do poziomu ostatniego sterownika od SanDisk (marzec 2019)<\/li>\n<\/ol>\n<p>\nPrzeprowadzi\u0142em testy Fusion ioMemory w por\u00f3wnaniu z do\u015b\u0107 nowoczesnym serwerowym SSD Intel P3700 PCI-E 3.0 x8 (ostatni kosztuje oko\u0142o cztery razy wi\u0119cej ni\u017c Fusion o podobnej pojemno\u015bci). Przy okazji, mo\u017cna zobaczy\u0107, jak bardzo ograniczona jest pr\u0119dko\u015b\u0107 z powodu magistrali x4.<\/p>\n<p>Fusion PX600 1.3TB PCI-E 2.0 x8<br \/>\nIntel P3700 1.6TB PCI-E 3.0 x4<\/p>\n<p><img decoding=\"async\" alt=\"Rozbudowa systemu dyskowego starego serwera z szyn\u0105 PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/7157ec6e43cac87fc0cdf5dd2887cfac.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<img decoding=\"async\" alt=\"Rozbudowa systemu dyskowego starego serwera z szyn\u0105 PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/f5db5f37b300332bd787d5b2fe57b67e.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>\nTak, liniowa pr\u0119dko\u015b\u0107 odczytu jest zdecydowanie ograniczona w przypadku Intel P3700. Z specyfikacji powinna wynosi\u0107 2800 MB\/s, a mamy 1469 MB\/s. Cho\u0107 og\u00f3lnie mo\u017cna powiedzie\u0107, \u017ce przy magistrali PCIe 2.0 mo\u017cna u\u017cywa\u0107 serwerowych SSD PCI-E 3.0 x4, je\u015bli uda si\u0119 je zdoby\u0107 w rozs\u0105dnej cenie.<\/p>\n<h3>Wnioski<\/h3>\n<p>\nDyskow\u0105 subsyst\u00eam\u0119 starego serwera z magistral\u0105 PCI-E 1.0 lub 2.0 mo\u017cna poprawi\u0107 dzi\u0119ki zastosowaniu SSD, kt\u00f3re potrafi\u0105 wykorzysta\u0107 8 linii PCI-E, co zapewnia przepustowo\u015b\u0107 do 4 GB\/s (PCI-E 2.0) lub 2 GB\/s (PCI-E 1.0). Najbardziej op\u0142acalne jest to zrobi\u0107, korzystaj\u0105c z moralnie przestarza\u0142ych SSD PCI-E 2.0.<\/p>\n<p>S\u0105 r\u00f3wnie\u017c proste do wdro\u017cenia kompromisowe rozwi\u0105zania zwi\u0105zane z zakupem klucza CacheCade dla kontroler\u00f3w LSI lub wymiany kontrolera Adaptec na wersj\u0119 Q.<\/p>\n<p>I zupe\u0142nie banalny spos\u00f3b \u2014 to zakup (raid) kontrolera SATA III, aby SSD dzia\u0142a\u0142y z pe\u0142n\u0105 pr\u0119dko\u015bci\u0105 i mog\u0142y obs\u0142u\u017cy\u0107 wszystko, co wymaga szybko\u015bci.<br \/>\n<br \/>\u0179r\u00f3d\u0142o: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/454222\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u041f\u043e\u0447\u0435\u043c\u0443 \u0442\u0435\u043c\u043e\u0439 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0432\u044b\u0431\u0440\u0430\u043d \u0430\u043f\u0433\u0440\u0435\u0439\u0434 \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b\u041f\u043e\u043d\u044f\u0442\u043d\u043e, \u0447\u0442\u043e \u0432 \u043f\u0435\u0440\u0432\u0443\u044e \u043e\u0447\u0435\u0440\u0435\u0434\u044c \u043d\u0443\u0436\u043d\u043e, \u043a\u0430\u043a \u043f\u0440\u0430\u0432\u0438\u043b\u043e: \u0423\u0432\u0435\u043b\u0438\u0447\u0438\u0442\u044c \u043e\u043f\u0435\u0440\u0430\u0442\u0438\u0432\u043d\u0443\u044e \u043f\u0430\u043c\u044f\u0442\u044c. \u042d\u0442\u043e \u043d\u0430\u0441\u0442\u043e\u043b\u044c\u043a\u043e \u043e\u0447\u0435\u0432\u0438\u0434\u043d\u044b\u0439 \u0445\u043e\u0434, \u0447\u0442\u043e \u044f \u0434\u0430\u0436\u0435 \u043d\u0435 \u0441\u0447\u0451\u043b \u043d\u0443\u0436\u043d\u044b\u043c \u043f\u0438\u0441\u0430\u0442\u044c \u043e\u0431 \u044d\u0442\u043e\u043c \u0432 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0435 \u041f\u043e\u0441\u0442\u0430\u0432\u0438\u0442\u044c \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440(\u044b) \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u043e\u0431\u0430 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u0430 \u043d\u0430 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0432\u0435\u0440\u0441\u0438\u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u044b\u0435 \u0441\u043e\u043a\u0435\u0442\u0430\u043c\u0438 \u0441\u0435\u0440\u0432\u0435\u0440\u0430. \u0414\u043b\u044f \u0441\u0442\u0430\u0440\u044b\u0445 \u0441\u0435\u0440\u0432\u0435\u0440\u043e\u0432, \u0447\u0442\u043e \u043f\u0430\u043c\u044f\u0442\u044c, \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u044b, \u043a\u0430\u043a [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":26262,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-34884","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/pl\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"pl_PL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47Upgrade \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0442\u0430\u0440\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 \u0441 \u0448\u0438\u043d\u043e\u0439 PCIe 1.0 \u2014 2.0 | ProHoster\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/pl\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:01:01+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:01:01+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Upgrade dyskowej subsyst\u00eam\u0119 starego serwera z magistral\u0105 PCIe 1.0 \u2014 2.0 | ProHoster","description":"","canonical_url":"https:\/\/prohoster.info\/pl\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"pl_PL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47Upgrade \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0442\u0430\u0440\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 \u0441 \u0448\u0438\u043d\u043e\u0439 PCIe 1.0 \u2014 2.0 | ProHoster","og:url":"https:\/\/prohoster.info\/pl\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:01:01+00:00","article:modified_time":"2019-10-31T19:01:01+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"34884","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-21 20:58:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 02:13:27","updated":"2026-01-21 20:58:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/posts\/34884","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/comments?post=34884"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/posts\/34884\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/media\/26262"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/media?parent=34884"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/categories?post=34884"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/tags?post=34884"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}