{"id":94739,"date":"2020-09-20T19:42:27","date_gmt":"2020-09-20T17:42:27","guid":{"rendered":"https:\/\/prohoster.info\/blog\/administrirovanie\/prakticheskij-primer-podklyucheniya-hranilishha-na-baze-ceph-v-klaster-kubernetes"},"modified":"2021-01-02T13:05:08","modified_gmt":"2021-01-02T11:05:08","slug":"prakticheskij-primer-podklyucheniya-hranilishha-na-baze-ceph-v-klaster-kubernetes","status":"publish","type":"post","link":"https:\/\/prohoster.info\/pl\/blog\/administrirovanie\/prakticheskij-primer-podklyucheniya-hranilishha-na-baze-ceph-v-klaster-kubernetes","title":{"rendered":"Praktyczny przyk\u0142ad po\u0142\u0105czenia pami\u0119ci masowej opartej na Ceph w klastrze Kubernetes","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Container Storage Interface (CSI) \u2013 to zunifikowany interfejs wsp\u00f3\u0142pracy Kubernetes z systemami pami\u0119ci masowej. Kr\u00f3tko o nim ju\u017c <noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/southbridge\/blog\/519130\/\">opowiadali\u015bmy<\/a><\/noindex>, a dzi\u015b dok\u0142adniej przyjrzymy si\u0119 powi\u0105zaniu CSI z Ceph: poka\u017cemy, jak <noindex><a rel=\"nofollow\" href=\"http:\/\/to.slurm.io\/WkM2Eg\">pod\u0142\u0105czy\u0107 pami\u0119\u0107 Ceph<\/a><\/noindex> do klastra Kubernetes.<br \/>\nW artykule znajduje si\u0119 kilka rzeczywistych, cho\u0107 nieco uproszczonych dla \u0142atwiejszego przyswajania przyk\u0142ad\u00f3w. Instalacja i konfiguracja klastr\u00f3w Ceph i Kubernetes nie s\u0105 omawiane.<\/p>\n<p>Ciekawi ci\u0119, jak to dzia\u0142a?<\/p>\n<p><img decoding=\"async\" alt=\"Praktyczny przyk\u0142ad po\u0142\u0105czenia pami\u0119ci masowej opartej na Ceph w klastrze Kubernetes\" src=\"\/wp-content\/uploads\/2020\/09\/db0a1d1e4c38c693f591057a219c141c.jpg\" style=\"display:block;margin: 0 auto;\"><\/p>\n<p><noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<p>Zatem masz pod r\u0119k\u0105 klaster Kubernetes, na przyk\u0142ad <noindex><a rel=\"nofollow\" href=\"https:\/\/github.com\/kubernetes-sigs\/kubespray\">kubespray<\/a><\/noindex>. Obok dzia\u0142a klaster Ceph \u2014 mo\u017cna go r\u00f3wnie\u017c zainstalowa\u0107, na przyk\u0142ad przy u\u017cyciu tego <noindex><a rel=\"nofollow\" href=\"https:\/\/github.com\/ceph\/ceph-ansible\">zestawu playbook\u00f3w<\/a><\/noindex>. Mam nadziej\u0119, \u017ce nie trzeba wspomina\u0107, \u017ce dla produkcji mi\u0119dzy nimi musi by\u0107 sie\u0107 o przepustowo\u015bci co najmniej 10 Gb\/s.<\/p>\n<p>Je\u015bli to wszystko masz, jed\u017amy dalej!<\/p>\n<p>Najpierw wejd\u017amy na jeden z w\u0119z\u0142\u00f3w klastra Ceph i sprawd\u017amy, czy wszystko w porz\u0105dku:<\/p>\n<pre><code class=\"plaintext\">ceph health\nceph -s<\/code><\/pre>\n<p>Nast\u0119pnie tutaj utworzymy pul\u0119 dla dysk\u00f3w RBD:<\/p>\n<pre><code class=\"plaintext\">ceph osd pool create kube 32\nceph osd pool application enable kube rbd<\/code><\/pre>\n<p>Przechodzimy do klastra Kubernetes. Tam najpierw zainstalujemy sterownik Ceph CSI dla RBD. Instalacj\u0119 przeprowadzimy, jak nale\u017cy, przez Helm.<br \/>\nDodajemy repozytorium z chartem i otrzymujemy zestaw zmiennych chartu ceph-csi-rbd:<\/p>\n<pre><code class=\"plaintext\">helm repo add ceph-csi https:\/\/ceph.github.io\/csi-charts\nhelm inspect values ceph-csi\/ceph-csi-rbd &gt; cephrbd.yml<\/code><\/pre>\n<p>Teraz nale\u017cy wype\u0142ni\u0107 plik cephrbd.yml. W tym celu poznajmy identyfikator klastra i adresy IP monitor\u00f3w w Ceph:<\/p>\n<pre><code class=\"plaintext\">ceph fsid  # w ten spos\u00f3b poznamy clusterID\nceph mon dump  # a w ten spos\u00f3b zobaczymy adresy IP monitor\u00f3w<\/code><\/pre>\n<p>Otrzymane warto\u015bci wprowadzamy do pliku cephrbd.yml. Przy okazji w\u0142\u0105czamy tworzenie polityk PSP (Pod Security Policies). Opcje w sekcjach <strong>nodeplugin<\/strong> i <strong>provisioner<\/strong> s\u0105 ju\u017c w pliku, mo\u017cna je poprawi\u0107 w spos\u00f3b pokazany poni\u017cej:<\/p>\n<pre><code class=\"plaintext\">csiConfig:\n  - clusterID: \"bcd0d202-fba8-4352-b25d-75c89258d5ab\"\n    monitors:\n      - \"v2:172.18.8.5:3300\/0,v1:172.18.8.5:6789\/0\"\n      - \"v2:172.18.8.6:3300\/0,v1:172.18.8.6:6789\/0\"\n      - \"v2:172.18.8.7:3300\/0,v1:172.18.8.7:6789\/0\"\n\nnodeplugin:\n  podSecurityPolicy:\n    enabled: true\n\nprovisioner:\n  podSecurityPolicy:\n    enabled: true<\/code><\/pre>\n<p>Nast\u0119pnie wszystko, co musimy zrobi\u0107, to zainstalowa\u0107 chart w klastrze Kubernetes.<\/p>\n<pre><code class=\"plaintext\">helm upgrade -i ceph-csi-rbd ceph-csi\/ceph-csi-rbd -f cephrbd.yml -n ceph-csi-rbd --create-namespace<\/code><\/pre>\n<p>\u015awietnie, sterownik RBD dzia\u0142a!<br \/>\nUtw\u00f3rzmy w Kubernetes now\u0105 klas\u0119 StorageClass. W tym celu zn\u00f3w musimy troch\u0119 popracowa\u0107 z Ceph.<\/p>\n<p>Tworzymy nowego u\u017cytkownika w Ceph i przyznajemy mu prawa do zapisu w puli <strong>kube<\/strong>:<\/p>\n<pre><code class=\"plaintext\">ceph auth get-or-create client.rbdkube mon 'profile rbd' osd 'profile rbd pool=kube'<\/code><\/pre>\n<p>A teraz sprawd\u017amy klucz dost\u0119pu tam samo:<\/p>\n<pre><code class=\"plaintext\">ceph auth get-key client.rbdkube<\/code><\/pre>\n<p>Polecenie zwr\u00f3ci co\u015b podobnego:<\/p>\n<pre><code class=\"plaintext\">AQCO9NJbhYipKRAAMqZsnqqS\/T8OYQX20xIa9A==<\/code><\/pre>\n<p>Zapiszemy t\u0119 warto\u015b\u0107 w Sekrecie w klastrze Kubernetes \u2014 tam, gdzie jest potrzebna <strong>userKey<\/strong>:<\/p>\n<pre><code class=\"plaintext\">---\napiVersion: v1\nkind: Secret\nmetadata:\n  name: csi-rbd-secret\n  namespace: ceph-csi-rbd\nstringData:\n  # Warto\u015bci kluczy odpowiadaj\u0105 nazwie u\u017cytkownika i jego kluczowi, jak podane w\n  # klastrze Ceph. ID u\u017cytkownika musi mie\u0107 dost\u0119p do puli,\n  # podanej w klasie storage\n  userID: rbdkube\n  userKey:<\/code><\/pre>\n<p>I tworzymy nasz sekret:<\/p>\n<pre><code class=\"plaintext\">kubectl apply -f secret.yaml<\/code><\/pre>\n<p>Nast\u0119pnie potrzebujemy mniej wi\u0119cej takiego manifestu StorageClass:<\/p>\n<pre><code class=\"plaintext\">---\napiVersion: storage.k8s.io\/v1\nkind: StorageClass\nmetadata:\n   name: csi-rbd-sc\nprovisioner: rbd.csi.ceph.com\nparameters:\n   clusterID: \n   pool: kube\n\n   imageFeatures: layering\n\n   # Te sekrety powinny zawiera\u0107 dane do autoryzacji\n   # w twojej puli.\n   csi.storage.k8s.io\/provisioner-secret-name: csi-rbd-secret\n   csi.storage.k8s.io\/provisioner-secret-namespace: ceph-csi-rbd\n   csi.storage.k8s.io\/controller-expand-secret-name: csi-rbd-secret\n   csi.storage.k8s.io\/controller-expand-secret-namespace: ceph-csi-rbd\n   csi.storage.k8s.io\/node-stage-secret-name: csi-rbd-secret\n   csi.storage.k8s.io\/node-stage-secret-namespace: ceph-csi-rbd\n\n   csi.storage.k8s.io\/fstype: ext4\n\nreclaimPolicy: Delete\nallowVolumeExpansion: true\nmountOptions:\n  - discard<\/code><\/pre>\n<p>Nale\u017cy wprowadzi\u0107 <strong>clusterID<\/strong>, kt\u00f3ry ju\u017c poznali\u015bmy za pomoc\u0105 polecenia <em>ceph fsid<\/em>, i zastosowa\u0107 ten manifest w klastrze Kubernetes:<\/p>\n<pre><code class=\"plaintext\">kubectl apply -f storageclass.yaml<\/code><\/pre>\n<p>Aby sprawdzi\u0107 wsp\u00f3\u0142prac\u0119 klastr\u00f3w, stw\u00f3rzmy taki PVC (Persistent Volume Claim):<\/p>\n<pre><code class=\"plaintext\">apiVersion: v1\nkind: PersistentVolumeClaim\nmetadata:\n  name: rbd-pvc\nspec:\n  accessModes:\n  - ReadWriteOnce\n  resources:\n    requests:\n      storage: 1Gi\n  storageClassName: csi-rbd-sc<\/code><\/pre>\n<p>Od razu sprawd\u017amy, jak Kubernetes utworzy\u0142 w Ceph \u017c\u0105dany wolumen:<\/p>\n<pre><code class=\"plaintext\">kubectl get pvc\nkubectl get pv<\/code><\/pre>\n<p>Wydaje si\u0119, \u017ce wszystko jest w porz\u0105dku! A jak to wygl\u0105da po stronie Ceph?<br \/>\nUzyskujemy list\u0119 wolumen\u00f3w w puli i przegl\u0105damy informacje o naszym wolumenie:<\/p>\n<pre><code class=\"plaintext\">rbd ls -p kube\nrbd -p kube info csi-vol-eb3d257d-8c6c-11ea-bff5-6235e7640653  # tu oczywi\u015bcie b\u0119dzie inny ID wolumenu, kt\u00f3ry podano w poprzednim poleceniu<\/code><\/pre>\n<p>Teraz sp\u00f3jrzmy, jak dzia\u0142a zmiana rozmiaru wolumenu RBD.<br \/>\nZmieni\u0107 rozmiar wolumenu w manife\u015bcie pvc.yaml na 2Gi i zastosowa\u0107 go:<\/p>\n<pre><code class=\"plaintext\">kubectl apply -f pvc.yaml<\/code><\/pre>\n<p>Poczekajmy, a\u017c zmiany wejd\u0105 w \u017cycie, i jeszcze raz sprawd\u017amy rozmiar wolumenu.<\/p>\n<pre><code class=\"plaintext\">rbd -p kube info csi-vol-eb3d257d-8c6c-11ea-bff5-6235e7640653\n\nkubectl get pv\nkubectl get pvc<\/code><\/pre>\n<p>Widzimy, \u017ce rozmiar PVC si\u0119 nie zmieni\u0142. Aby pozna\u0107 przyczyn\u0119, mo\u017cemy zapyta\u0107 Kubernetes o opis PVC w formacie YAML:<\/p>\n<pre><code class=\"plaintext\">kubectl get pvc rbd-pvc -o yaml<\/code><\/pre>\n<p>A oto problem:<\/p>\n<p><em>message: Waiting for user to (re-)start a pod to finish file system resize of volume on node. type: FileSystemResizePending<\/em><\/p>\n<p>To znaczy, \u017ce dysk si\u0119 zwi\u0119kszy\u0142, ale system plik\u00f3w na nim \u2014 nie.<br \/>\nAby zwi\u0119kszy\u0107 system plik\u00f3w, trzeba zamontowa\u0107 wolumen. Stworzony PVC\/PV obecnie w \u017caden spos\u00f3b nie jest u\u017cywany.<\/p>\n<p>Mo\u017cemy stworzy\u0107 testowy Pod, na przyk\u0142ad tak:<\/p>\n<pre><code class=\"plaintext\">---\napiVersion: v1\nkind: Pod\nmetadata:\n  name: csi-rbd-demo-pod\nspec:\n  containers:\n    - name: web-server\n      image: nginx:1.17.6\n      volumeMounts:\n        - name: mypvc\n          mountPath: \/data\n  volumes:\n    - name: mypvc\n      persistentVolumeClaim:\n        claimName: rbd-pvc\n        readOnly: false<\/code><\/pre>\n<p>A teraz przyjrzyjmy si\u0119 PVC:<\/p>\n<pre><code class=\"plaintext\">kubectl get pvc<\/code><\/pre>\n<p>Rozmiar si\u0119 zmieni\u0142, wszystko w porz\u0105dku.<\/p>\n<p>W pierwszej cz\u0119\u015bci pracowali\u015bmy z urz\u0105dzeniem blokowym RBD (nazwa pochodzi od Rados Block Device), jednak nie jest to rozwi\u0105zanie, je\u015bli potrzebujemy jednoczesnej pracy z tym dyskiem r\u00f3\u017cnych mikrous\u0142ug. Do pracy z plikami, a nie obrazem dysku, znacznie lepiej nadaje si\u0119 CephFS.<br \/>\nNa przyk\u0142adzie klastr\u00f3w Ceph i Kubernetes skonfigurujemy CSI oraz inne konieczne zasoby do pracy z CephFS.<\/p>\n<p>Uzyskamy warto\u015bci z potrzebnego nam nowego Helm-charta:<\/p>\n<pre><code class=\"plaintext\">helm inspect values ceph-csi\/ceph-csi-cephfs &gt; cephfs.yml<\/code><\/pre>\n<p>Ponownie musimy wype\u0142ni\u0107 plik cephfs.yml. Jak wcze\u015bniej, pomog\u0105 nam polecenia Ceph:<\/p>\n<pre><code class=\"plaintext\">ceph fsid\nceph mon dump<\/code><\/pre>\n<p>Wype\u0142niamy plik warto\u015bci w ten spos\u00f3b:<\/p>\n<pre><code class=\"plaintext\">csiConfig:\n  - clusterID: \"bcd0d202-fba8-4352-b25d-75c89258d5ab\"\n    monitors:\n      - \"172.18.8.5:6789\"\n      - \"172.18.8.6:6789\"\n      - \"172.18.8.7:6789\"\n\nnodeplugin:\n  httpMetrics:\n    enabled: true\n    containerPort: 8091\n  podSecurityPolicy:\n    enabled: true\n\nprovisioner:\n  replicaCount: 1\n  podSecurityPolicy:\n    enabled: true<\/code><\/pre>\n<p>Zauwa\u017c, \u017ce adresy monitor\u00f3w s\u0105 podawane w prostym formacie address:port. Aby zamontowa\u0107 cephfs na w\u0119\u017ale, te adresy s\u0105 przekazywane do modu\u0142u j\u0105dra, kt\u00f3ry jeszcze nie obs\u0142uguje protoko\u0142u monitor\u00f3w v2.<br \/>\nPort dla httpMetrics (tutaj Prometheus b\u0119dzie zbiera\u0107 metryki) zmieniamy, aby nie kolidowa\u0142 z nginx-proxy, kt\u00f3ry jest instalowany przez Kubespray. Mo\u017cliwe, \u017ce nie b\u0119dziesz tego potrzebowa\u0107.<\/p>\n<p>Instalujemy Helm-chart w klastrze Kubernetes:<\/p>\n<pre><code class=\"plaintext\">helm upgrade -i ceph-csi-cephfs ceph-csi\/ceph-csi-cephfs -f cephfs.yml -n ceph-csi-cephfs --create-namespace<\/code><\/pre>\n<p>Przechodzimy do magazynu danych Ceph, aby utworzy\u0107 tam oddzielnego u\u017cytkownika. W dokumentacji wskazano, \u017ce prowizjoner CephFS potrzebuje uprawnie\u0144 administratora klastra. Jednak stworzymy oddzielnego u\u017cytkownika <em>fs<\/em> z ograniczonymi prawami:<\/p>\n<pre><code class=\"plaintext\">ceph auth get-or-create client.fs mon 'allow r' mgr 'allow rw' mds 'allow rws' osd 'allow rw pool=cephfs_data, allow rw pool=cephfs_metadata'<\/code><\/pre>\n<p>I od razu sprawdzimy jego klucz dost\u0119pu, przyda nam si\u0119 p\u00f3\u017aniej:<\/p>\n<pre><code class=\"plaintext\">ceph auth get-key client.fs<\/code><\/pre>\n<p>Utworzymy oddzielne Secret i StorageClass.<br \/>\nNic nowego, ju\u017c to widzieli\u015bmy na przyk\u0142adzie RBD:<\/p>\n<pre><code class=\"plaintext\">---\napiVersion: v1\nkind: Secret\nmetadata:\n  name: csi-cephfs-secret\n  namespace: ceph-csi-cephfs\nstringData:\n  # Wymagane do dynamicznie tworzonych wolumen\u00f3w\n  adminID: fs\n  adminKey:<\/code><\/pre>\n<p>Zastosowujemy manifest:<\/p>\n<pre><code class=\"plaintext\">kubectl apply -f secret.yaml<\/code><\/pre>\n<p>A teraz \u2013 oddzielny StorageClass:<\/p>\n<pre><code class=\"plaintext\">---\napiVersion: storage.k8s.io\/v1\nkind: StorageClass\nmetadata:\n  name: csi-cephfs-sc\nprovisioner: cephfs.csi.ceph.com\nparameters:\n  clusterID: \n\n  # Nazwa systemu plik\u00f3w CephFS, na kt\u00f3rym zostanie utworzony wolumin\n  fsName: cephfs\n\n  # (opcjonalnie) Pula Ceph, w kt\u00f3rej b\u0119d\u0105 przechowywane dane woluminu\n  # pool: cephfs_data\n\n  # (opcjonalnie) Opcje montowania dla Ceph-fuse, oddzielone przecinkami\n  # na przyk\u0142ad:\n  # fuseMountOptions: debug\n\n  # (opcjonalnie) Opcje montowania CephFS dla j\u0105dra, oddzielone przecinkami\n  # Zobacz man mount.ceph, aby uzyska\u0107 list\u0119 tych opcji. Na przyk\u0142ad:\n  # kernelMountOptions: readdir_max_bytes=1048576,norbytes\n\n  # Sekrety musz\u0105 zawiera\u0107 dost\u0119p dla administratora i\/lub u\u017cytkownika Ceph.\n  csi.storage.k8s.io\/provisioner-secret-name: csi-cephfs-secret\n  csi.storage.k8s.io\/provisioner-secret-namespace: ceph-csi-cephfs\n  csi.storage.k8s.io\/controller-expand-secret-name: csi-cephfs-secret\n  csi.storage.k8s.io\/controller-expand-secret-namespace: ceph-csi-cephfs\n  csi.storage.k8s.io\/node-stage-secret-name: csi-cephfs-secret\n  csi.storage.k8s.io\/node-stage-secret-namespace: ceph-csi-cephfs\n\n  # (opcjonalnie) Sterownik mo\u017ce u\u017cywa\u0107 albo ceph-fuse (fuse), \n  # albo ceph kernelclient (kernel).\n  # Je\u015bli nie okre\u015blono, u\u017cywane b\u0119dzie domy\u015blne montowanie wolumin\u00f3w,\n  # kt\u00f3re okre\u015bla wyszukiwanie ceph-fuse i mount.ceph\n  # mounter: kernel\nreclaimPolicy: Delete\nallowVolumeExpansion: true\nmountOptions:\n  - debug<\/code><\/pre>\n<p>Wype\u0142nimy to tutaj <strong>clusterID<\/strong> i zastosujemy w Kubernetes:<\/p>\n<pre><code class=\"plaintext\">kubectl apply -f storageclass.yaml<\/code><\/pre>\n<h2 id=\"proverka\">Weryfikacja<\/h2>\n<p>Aby sprawdzi\u0107, jak w poprzednim przyk\u0142adzie, stworzymy PVC:<\/p>\n<pre><code class=\"plaintext\">---\napiVersion: v1\nkind: PersistentVolumeClaim\nmetadata:\n  name: csi-cephfs-pvc\nspec:\n  accessModes:\n    - ReadWriteMany\n  resources:\n    requests:\n      storage: 5Gi\n  storageClassName: csi-cephfs-sc<\/code><\/pre>\n<p>I sprawdzimy obecno\u015b\u0107 PVC\/PV:<\/p>\n<pre><code class=\"plaintext\">kubectl get pvc\nkubectl get pv<\/code><\/pre>\n<p>Je\u015bli chcesz zobaczy\u0107 pliki i katalogi w CephFS, mo\u017cesz zamontowa\u0107 ten system plik\u00f3w gdzie\u015b. Na przyk\u0142ad jak pokazano poni\u017cej.<\/p>\n<p>Wejd\u017a na jeden z w\u0119z\u0142\u00f3w klastra Ceph i wykonaj nast\u0119puj\u0105ce czynno\u015bci:<\/p>\n<pre><code class=\"plaintext\"># \u0422\u043e\u0447\u043a\u0430 \u043c\u043e\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f\nmkdir -p \/mnt\/cephfs\n\n# \u0421\u043e\u0437\u0434\u0430\u0451\u043c \u0444\u0430\u0439\u043b \u0441 \u043a\u043b\u044e\u0447\u043e\u043c \u0430\u0434\u043c\u0438\u043d\u0438\u0441\u0442\u0440\u0430\u0442\u043e\u0440\u0430\nceph auth get-key client.admin &gt;\/etc\/ceph\/secret.key\n\n# \u0414\u043e\u0431\u0430\u0432\u043b\u044f\u0435\u043c \u0437\u0430\u043f\u0438\u0441\u044c \u0432 \/etc\/fstab\n# !! \u0418\u0437\u043c\u0435\u043d\u044f\u0435\u043c ip \u0430\u0434\u0440\u0435\u0441 \u043d\u0430 \u0430\u0434\u0440\u0435\u0441 \u043d\u0430\u0448\u0435\u0433\u043e \u0443\u0437\u043b\u0430\necho \"172.18.8.6:6789:\/ \/mnt\/cephfs ceph name=admin,secretfile=\/etc\/ceph\/secret.key,noatime,_netdev    0       2\" &gt;&gt; \/etc\/fstab\n\nmount \/mnt\/cephfs<\/code><\/pre>\n<p>Oczywi\u015bcie, takie montowanie FS na w\u0119\u017ale Ceph jest odpowiednie tylko do cel\u00f3w edukacyjnych, jakimi si\u0119 teraz zajmujemy w naszych <noindex><a rel=\"nofollow\" href=\"http:\/\/slurm.io\">kursach Slurm<\/a><\/noindex>. Nie s\u0105dz\u0119, \u017ceby kto\u015b to robi\u0142 w produkcji, du\u017ce ryzyko przypadkowego nadpisania wa\u017cnych plik\u00f3w.<\/p>\n<p>Na koniec sprawd\u017amy, jak wygl\u0105da sytuacja w przypadku CephFS ze zmian\u0105 rozmiar\u00f3w wolumin\u00f3w. Wracamy do Kubernetes i edytujemy nasz manifest dla PVC \u2014 zwi\u0119kszamy rozmiar, na przyk\u0142ad do 7Gi.<\/p>\n<p>Zastosujemy edytowany plik:<\/p>\n<pre><code class=\"plaintext\">kubectl apply -f pvc.yaml<\/code><\/pre>\n<p>Zobaczymy, jak zmieni\u0142a si\u0119 kwota w zamontowanym katalogu:<\/p>\n<pre><code class=\"plaintext\">getfattr -n ceph.quota.max_bytes<\/code><\/pre>\n<p>Aby u\u017cy\u0107 tej komendy, mo\u017cesz potrzebowa\u0107 zainstalowa\u0107 w systemie pakiet <strong>attr<\/strong>.<\/p>\n<h2 id=\"glaza-boyatsya-a-ruki-delayut\">Oczy strach, r\u0119ce dzia\u0142aj\u0105<\/h2>\n<p>Na pierwszy rzut oka wszystkie te zakl\u0119cia i d\u0142ugie manifesty YAML wydaj\u0105 si\u0119 skomplikowane, ale w praktyce studenci Slurma radz\u0105 sobie z nimi do\u015b\u0107 szybko.<br \/>\nW tym artykule nie zanurzyli\u015bmy si\u0119 w szczeg\u00f3\u0142y \u2014 na to jest oficjalna dokumentacja. Je\u015bli interesuj\u0105 Ci\u0119 szczeg\u00f3\u0142y konfiguracji przechowywania Ceph w po\u0142\u0105czeniu z klastrem Kubernetes, pomog\u0105 te linki:<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/kubernetes.io\/docs\/concepts\/storage\/volumes\/\">Og\u00f3lne zasady dzia\u0142ania Kubernetes z wolumenami<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/ceph.readthedocs.io\/en\/latest\/rbd\/\">Dokumentacja RBD<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/docs.ceph.com\/docs\/master\/rbd\/rbd-kubernetes\/\">Integracja RBD i Kubernetes z perspektywy Ceph<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/github.com\/ceph\/ceph-csi\/blob\/master\/docs\/deploy-rbd.md\">Integracja RBD i Kubernetes z perspektywy CSI<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/ceph.readthedocs.io\/en\/latest\/cephfs\/\">Og\u00f3lna dokumentacja CephFS<\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/github.com\/ceph\/ceph-csi\/blob\/master\/docs\/deploy-cephfs.md\">Integracja CephFS i Kubernetes z perspektywy CSI<\/a><\/noindex><\/p>\n<p>Na kursie Slurma <noindex><a rel=\"nofollow\" href=\"http:\/\/to.slurm.io\/6p9lng\">Kubernetes Podstawy<\/a><\/noindex> mo\u017cesz p\u00f3j\u015b\u0107 jeszcze krok dalej i uruchomi\u0107 w Kubernetes aplikacj\u0119, kt\u00f3ra b\u0119dzie wykorzystywa\u0107 CephFS jako magazyn dla plik\u00f3w. Poprzez \u017c\u0105dania GET\/POST b\u0119dziesz m\u00f3g\u0142 przesy\u0142a\u0107 pliki i je odbiera\u0107 z Ceph.<\/p>\n<p>A je\u015bli bardziej interesuje Ci\u0119 przechowywanie danych, zapisz si\u0119 na <noindex><a rel=\"nofollow\" href=\"http:\/\/to.slurm.io\/WkM2Eg\">nowy kurs dotycz\u0105cy Ceph<\/a><\/noindex>. Podczas trwaj\u0105cych test\u00f3w beta kurs mo\u017cna zdoby\u0107 ze zni\u017ck\u0105 i wp\u0142yn\u0105\u0107 na jego zawarto\u015b\u0107.<\/p>\n<p><em>Autor artyku\u0142u: Aleksander Szwalow, in\u017cynier praktykuj\u0105cy <noindex><a rel=\"nofollow\" href=\"http:\/\/to.slurm.io\/ophLww\">Southbridge<\/a><\/noindex>, Certified Kubernetes Administrator, autor i tw\u00f3rca kurs\u00f3w Slurma.<\/em><\/p>\n<p>\u0179r\u00f3d\u0142o: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/southbridge\/blog\/519642\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>Container Storage Interface (CSI) \u2014 \u044d\u0442\u043e \u0443\u043d\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f Kubernetes \u0438 \u0441\u0438\u0441\u0442\u0435\u043c \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u0434\u0430\u043d\u043d\u044b\u0445. \u0412\u043a\u0440\u0430\u0442\u0446\u0435 \u043e \u043d\u0451\u043c \u043c\u044b \u0443\u0436\u0435 \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u044b\u0432\u0430\u043b\u0438, \u0430 \u0441\u0435\u0433\u043e\u0434\u043d\u044f \u043f\u043e\u0434\u0440\u043e\u0431\u043d\u0435\u0435 \u0440\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0438\u043c \u0441\u0432\u044f\u0437\u043a\u0443 CSI \u0438 Ceph: \u043f\u043e\u043a\u0430\u0436\u0435\u043c, \u043a\u0430\u043a \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0438\u0442\u044c \u0445\u0440\u0430\u043d\u0438\u043b\u0438\u0449\u0435 Ceph \u043a \u043a\u043b\u0430\u0441\u0442\u0435\u0440\u0443 Kubernetes. \u0412 \u0441\u0442\u0430\u0442\u044c\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u044b \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0435, \u0445\u043e\u0442\u044f \u0438 \u043d\u0435\u043c\u043d\u043e\u0433\u043e \u0443\u043f\u0440\u043e\u0449\u0451\u043d\u043d\u044b\u0435 \u0434\u043b\u044f \u0443\u0434\u043e\u0431\u0441\u0442\u0432\u0430 \u0432\u043e\u0441\u043f\u0440\u0438\u044f\u0442\u0438\u044f \u043f\u0440\u0438\u043c\u0435\u0440\u044b. \u0423\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0443 \u0438 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0443 \u043a\u043b\u0430\u0441\u0442\u0435\u0440\u043e\u0432 Ceph \u0438 Kubernetes [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":94740,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-94739","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Container Storage Interface (CSI) \u2014 \u044d\u0442\u043e \u0443\u043d\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f Kubernetes \u0438 \u0441\u0438\u0441\u0442\u0435\u043c \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u0434\u0430\u043d\u043d\u044b\u0445.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/pl\/blog\/administrirovanie\/prakticheskij-primer-podklyucheniya-hranilishha-na-baze-ceph-v-klaster-kubernetes\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"pl_PL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u041f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0440\u0438\u043c\u0435\u0440 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0445\u0440\u0430\u043d\u0438\u043b\u0438\u0449\u0430 \u043d\u0430 \u0431\u0430\u0437\u0435 Ceph \u0432 \u043a\u043b\u0430\u0441\u0442\u0435\u0440 Kubernetes | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"Container Storage Interface (CSI) \u2014 \u044d\u0442\u043e \u0443\u043d\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f Kubernetes \u0438 \u0441\u0438\u0441\u0442\u0435\u043c \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u0434\u0430\u043d\u043d\u044b\u0445.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/pl\/blog\/administrirovanie\/prakticheskij-primer-podklyucheniya-hranilishha-na-baze-ceph-v-klaster-kubernetes\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-09-20T17:42:27+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2021-01-02T11:05:08+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Praktyczny przyk\u0142ad pod\u0142\u0105czenia przechowywania opartego na Ceph w klastrze Kubernetes | ProHoster","description":"Container Storage Interface (CSI) to ujednolicony interfejs komunikacji mi\u0119dzy Kubernetes a systemami przechowywania danych.","canonical_url":"https:\/\/prohoster.info\/pl\/blog\/administrirovanie\/prakticheskij-primer-podklyucheniya-hranilishha-na-baze-ceph-v-klaster-kubernetes","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"pl_PL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u041f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0440\u0438\u043c\u0435\u0440 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0445\u0440\u0430\u043d\u0438\u043b\u0438\u0449\u0430 \u043d\u0430 \u0431\u0430\u0437\u0435 Ceph \u0432 \u043a\u043b\u0430\u0441\u0442\u0435\u0440 Kubernetes | ProHoster","og:description":"Container Storage Interface (CSI) \u2014 \u044d\u0442\u043e \u0443\u043d\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f Kubernetes \u0438 \u0441\u0438\u0441\u0442\u0435\u043c \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u0434\u0430\u043d\u043d\u044b\u0445.","og:url":"https:\/\/prohoster.info\/pl\/blog\/administrirovanie\/prakticheskij-primer-podklyucheniya-hranilishha-na-baze-ceph-v-klaster-kubernetes","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-09-20T17:42:27+00:00","article:modified_time":"2021-01-02T11:05:08+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"94739","title":null,"description":"","keywords":"","keyphrases":null,"primary_term":null,"canonical_url":"","og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 11:19:21","updated":"2022-09-30 10:03:10","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/posts\/94739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/comments?post=94739"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/posts\/94739\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/media\/94740"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/media?parent=94739"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/categories?post=94739"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/pl\/wp-json\/wp\/v2\/tags?post=94739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}