{"id":34884,"date":"2019-10-31T22:01:01","date_gmt":"2019-10-31T19:01:01","guid":{"rendered":"https:\/\/prohoster.info\/blog\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\/"},"modified":"2019-10-31T22:01:01","modified_gmt":"2019-10-31T19:01:01","slug":"upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","status":"publish","type":"post","link":"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","title":{"rendered":"Atualiza\u00e7\u00e3o do subsistema de disco de um servidor antigo com barramento PCIe 1.0 \u2014 2.0","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Atualiza\u00e7\u00e3o do subsistema de disco de um servidor antigo com barramento PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/68025340a72b1acac62371764f328712.jpg\" style=\"display:block;margin: 0 auto;\" \/><b class=\"spoiler_title\">Por que o tema deste artigo \u00e9 a atualiza\u00e7\u00e3o do subsistema de disco<\/b>\u00c9 claro que, em primeiro lugar, voc\u00ea geralmente precisa:<\/p>\n<ol>\n<li>Aumentar a mem\u00f3ria RAM. Essa \u00e9 uma medida t\u00e3o \u00f3bvia que eu nem considerei necess\u00e1rio escrever sobre isso no artigo principal.<\/li>\n<li>Instalar processadores adicionais ou substituir ambos os processadores por vers\u00f5es de alto desempenho que sejam suportadas pelos soquetes do servidor.<\/li>\n<\/ol>\n<p>\nPara servidores antigos, tanto a mem\u00f3ria quanto os processadores podem ser encontrados a pre\u00e7os muito baixos.<\/p>\n<p>Em determinado momento, todo propriet\u00e1rio de um servidor se depara com a quest\u00e3o \u2014 atualizar ou comprar um servidor novo.<\/p>\n<p>Uma vez que o pre\u00e7o de um servidor novo pode atingir milh\u00f5es de rublos, muitos optam pelo caminho da atualiza\u00e7\u00e3o.<\/p>\n<p>Para uma atualiza\u00e7\u00e3o bem-sucedida, \u00e9 muito importante utilizar compromissos, para que, por um custo insignificante (em rela\u00e7\u00e3o ao pre\u00e7o de um servidor novo), possamos obter um ganho significativo de desempenho.<\/p>\n<p>O artigo apresenta uma lista de SSDs servidores PCI-E 2.0 x8, que est\u00e3o muito mais baratos agora, mencionando controladores RAID que suportam cache SSD e testando SSD SATA III na interface SATA II.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nA maneira mais \u00f3bvia de atualizar o subsistema de disco \u00e9 a migra\u00e7\u00e3o de HDD para SSD. Isso \u00e9 v\u00e1lido tanto para laptops quanto para servidores. Nos servidores, a \u00fanica diferen\u00e7a \u00e9 que o SSD pode ser facilmente configurado em RAID.<\/p>\n<p>No entanto, h\u00e1 nuances relacionadas ao fato de que pode n\u00e3o haver portas SATA III em um servidor antigo, e nesse caso ser\u00e1 necess\u00e1rio substituir ou instalar um controlador correspondente.<\/p>\n<p>Claro que tamb\u00e9m existem m\u00e9todos intermedi\u00e1rios.<\/p>\n<h2>Cache em SSD.<\/h2>\n<p>\nDe maneira geral, esse m\u00e9todo \u00e9 bastante adequado para bancos de dados, 1C, ou qualquer acesso aleat\u00f3rio. A velocidade realmente aumenta. Para arquivos enormes e videovigil\u00e2ncia, esse m\u00e9todo \u00e9 in\u00fatil.<\/p>\n<h3>Controladores RAID LSI (IBM, DELL, CISCO, Fujitsu)<\/h3>\n<p>\nA partir da s\u00e9rie 92xx, a LSI possui a tecnologia CacheCade 2.0, que permite usar quase qualquer SSD SATA como cache para o array RAID. Tanto para leitura quanto para grava\u00e7\u00e3o. E at\u00e9 mesmo criar um espelho a partir de SSDs de cache.<\/p>\n<p>Com controladores com marca, as coisas s\u00e3o mais complicadas. Isso se aplica especialmente \u00e0 IBM. As chaves e SSDs para CacheCade ter\u00e3o que ser comprados da IBM por pre\u00e7os exorbitantes, ent\u00e3o \u00e9 mais simples trocar o controlador por um LSI e comprar uma chave de hardware a um pre\u00e7o mais acess\u00edvel. As chaves de software custam consideravelmente mais do que as de hardware.<\/p>\n<h3>Controladores RAID Adaptec<\/h3>\n<p>\nOs controladores Adaptec possuem a tecnologia MaxCache, que tamb\u00e9m permite usar SSDs como cache. Estamos interessados nas vers\u00f5es dos controladores que terminam com a letra Q.<\/p>\n<p>Controladores Q conseguem utilizar quase qualquer SSD, e n\u00e3o apenas os SSDs fornecidos pela Adaptec.<\/p>\n<ul>\n<li>A partir do 5xxx, todos os controladores t\u00eam suporte para RAID H\u00edbrido. A ess\u00eancia dessa tecnologia \u00e9 que a leitura sempre \u00e9 feita a partir do SSD, quando existe um espelho em um dos discos que cont\u00e9m o SSD.<\/li>\n<li>5xxxQ, por exemplo, 5805ZQ. Esses controladores suportam o MaxCache 1.0. Apenas cache de leitura.<\/li>\n<li>6xxQ, por exemplo, 6805Q. MaxCache 2.0. Cache de leitura e grava\u00e7\u00e3o.<\/li>\n<li>7xxQ, por exemplo, 7805Q. MaxCache 3.0. Cache de leitura e grava\u00e7\u00e3o.<\/li>\n<li>8xxQ quase n\u00e3o faz sentido usar para upgrade devido aos pre\u00e7os altos.<\/li>\n<\/ul>\n<p>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/pc-administrator\/blog\/319214\/\">Artigo sobre cache em SSD no Habr\u00e9 (controladores e SO).<\/a><\/noindex><\/p>\n<h3>Tecnologias de software para cache em SSD<\/h3>\n<p>\nN\u00e3o vou abordar essas tecnologias. Quase todos os sistemas operacionais atualmente as suportam. Eu me lembro que ao usar btrfs, ele automaticamente redireciona os pedidos de leitura para o dispositivo com a fila mais curta \u2014 SSD.<\/p>\n<h2>SSD SATA III em uma interface SATA II<\/h2>\n<p>\nComo nem sempre h\u00e1 possibilidade e dinheiro para um novo controlador, surge a quest\u00e3o de qu\u00e3o bem os SSDs SATA III funcionam na interface desatualizada SATA II.<\/p>\n<p>Vamos realizar um pequeno teste. O sujeito do teste ser\u00e1 um SSD SATA III Intel S3710 de 400GB.<\/p>\n<p>Leitura aleat\u00f3ria, iops<br \/>\nLat\u00eancia m\u00e9dia de leitura, mS<br \/>\nGrava\u00e7\u00e3o aleat\u00f3ria, iops<br \/>\nLat\u00eancia m\u00e9dia de grava\u00e7\u00e3o, mS<br \/>\nLeitura linear, MB\/s<br \/>\nGrava\u00e7\u00e3o linear, MB\/s<\/p>\n<p>SATA II<br \/>\n21241<br \/>\n2<br \/>\n13580<br \/>\n4<br \/>\n282<br \/>\n235<\/p>\n<p>SATA III<br \/>\n68073<br \/>\n0.468<br \/>\n61392<br \/>\n0.52<br \/>\n514<br \/>\n462<\/p>\n<p>\n<b class=\"spoiler_title\">Comandos usados para testar a velocidade<\/b><\/p>\n<pre><code class=\"bash\">fio --name LinRead --eta-newline=5s --filename=\/dev\/sda --rw=read --size=500m --io_size=10g --blocksize=1024k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=1 --runtime=60 --group_reporting \nfio --name LinWrite --eta-newline=5s --filename=\/dev\/sda --rw=write --size=500m --io_size=10g --blocksize=1024k --ioengine=libaio --fsync=10000 --iodepth=32 --direct=1 --numjobs=1 --runtime=60 --group_reporting\n\nfio --name RandRead --eta-newline=5s --filename=\/dev\/sda --rw=randread --size=500m --io_size=10g --blocksize=4k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=4 --runtime=60 --group_reporting\n\nfio --name RandWrite --eta-newline=5s --filename=\/dev\/sda --rw=randwrite --size=500m --io_size=10g --blocksize=4k --ioengine=libaio --iodepth=32 --direct=1 --numjobs=4 --runtime=60 --group_reporting\n<\/code><\/pre>\n<p>Como se pode ver, a diferen\u00e7a em termos de velocidade linear, IOPS e lat\u00eancias \u00e9 bastante significativa, portanto, faz sentido usar apenas a interface SATA III; caso contr\u00e1rio, \u00e9 necess\u00e1rio usar um controlador.<\/p>\n<p>Para ser justo, posso dizer que, em <noindex><a rel=\"nofollow\" href=\"http:\/\/www.thg.ru\/storage\/ustanovka_ssd_v_sistemu_s_sata_3_gbits_test\/ustanovka_ssd_v_sistemu_s_sata_3_gbits_test-01.html\">outros experimentos,<\/a><\/noindex> a diferen\u00e7a na velocidade de leitura e grava\u00e7\u00e3o aleat\u00f3ria foi insignificante. \u00c9 poss\u00edvel que a grande diferen\u00e7a em IOPS entre SATA II e SATA III tenha ocorrido porque eu tinha um controlador SATA II bastante problem\u00e1tico ou um driver com alguns bugs.<\/p>\n<p>No entanto, o fato \u00e9 que \u00e9 preciso verificar a velocidade do SATA II \u2014 talvez voc\u00ea tenha um controlador t\u00e3o lento quanto. Nesse caso, \u00e9 obrigat\u00f3ria a transi\u00e7\u00e3o para um controlador SATA III.<\/p>\n<h2>SSD PCIe na linha PCI-e 2.0 ou 1.0<\/h2>\n<p>\nComo sabemos, os SSDs mais r\u00e1pidos s\u00e3o os PCI-e NVMe, que n\u00e3o s\u00e3o limitados pelos protocolos SAS ou SATA.<\/p>\n<p>No entanto, ao instalar SSDs PCI-e modernos, \u00e9 necess\u00e1rio considerar que a maioria deles utiliza apenas 4 linhas PCI-e, geralmente PCI-e 3.0 ou 3.1.<\/p>\n<p>Agora vejamos a tabela de velocidades da linha PCI-e.<\/p>\n<p>Capacidade de transfer\u00eancia PCI Express, GB\/s<\/p>\n<p>Ano <br \/>\n de lan\u00e7amento<\/p>\n<p>Vers\u00e3o<br \/>\nPCI Express<\/p>\n<p>Codifica\u00e7\u00e3o<\/p>\n<p>Velocidade<br \/>\ntransfer\u00eancia<\/p>\n<p>Capacidade de transfer\u00eancia em x linhas<\/p>\n<p>\u00d74<br \/>\n\u00d78<br \/>\n\u00d716<\/p>\n<p>2002<br \/>\n1.0<br \/>\n8b\/10b<\/p>\n<p>0.50 GB\/s<br \/>\n1.0 GB\/s<br \/>\n2.0 GB\/s<br \/>\n4.0 GB\/s<\/p>\n<p>2007<br \/>\n2.0<br \/>\n8b\/10b<\/p>\n<p>1.0 GB\/s<br \/>\n2.0 GB\/s<br \/>\n4.0 GB\/s<br \/>\n8.0 GB\/s<\/p>\n<p>2010<br \/>\n3.0<br \/>\n128b\/130b<\/p>\n<p>1.97 GB\/s<br \/>\n3.94 GB\/s<br \/>\n7.88 GB\/s<br \/>\n15.8 GB\/s<\/p>\n<p>Ao instalar um SSD PCI 3.0 x4 na linha PCI-e 2.0, ele funcionar\u00e1 com o mesmo n\u00famero de linhas, mas a uma velocidade significativamente menor. O problema \u00e9 que as velocidades lineares dos SSDs PCI-e modernos superam a capacidade de transfer\u00eancia da linha PCI-e 2.0 e ainda mais da PCI-e 1.0.<\/p>\n<h3>SSD M.2 e adaptador PCI-e<\/h3>\n<p>Existem boas op\u00e7\u00f5es de upgrade, como comprar um adaptador por 10 d\u00f3lares e instalar um SSD M.2 no servidor, mas novamente para SSDs de boa qualidade haver\u00e1 uma redu\u00e7\u00e3o na velocidade (especialmente na PCI-e 1.0), e os SSDs M.2 nem sempre s\u00e3o projetados para cargas de servidor: com alta resist\u00eancia ao desgaste, prote\u00e7\u00e3o de energia e estabilidade nas caracter\u00edsticas de velocidade devido ao preenchimento do cache SLC em modelos mais baratos.<\/p>\n<p>Assim, esse m\u00e9todo pode ser adequado apenas para um servidor com linha PCI-e 2.0 e carregando trabalho n\u00e3o cr\u00edtico.<\/p>\n<h3>SSD PCI-E 2.0 x8<\/h3>\n<p>\nO upgrade mais economicamente vi\u00e1vel \u00e9 o uso de SSDs PCI-E 2.0 x8 para servidores com linha PCI-e 1.0 (capacidade de at\u00e9 2 GB\/s) e PCI-e 2.0 (at\u00e9 4 GB\/s).<\/p>\n<p>Atualmente, \u00e9 poss\u00edvel comprar SSDs desse tipo para servidor de forma bastante barata, tanto em diversos marketplaces quanto em leil\u00f5es online, incluindo na R\u00fassia.<\/p>\n<p>Eu compilei uma tabela de SSDs que est\u00e3o moralmente obsoletos, mas que podem dar um \u00f3timo impulso ao seu antigo servidor. No final da tabela, adicionei alguns SSDs com interface PCI-E 3.0 x8. Quem sabe voc\u00ea consegue encontr\u00e1-los a um pre\u00e7o razo\u00e1vel.<\/p>\n<p>Nome<br \/>\nTB<br \/>\nPBW<br \/>\nPCI-E<br \/>\n4k read iops, K<br \/>\n4k write iops, K<br \/>\nleitura, MB\/s<br \/>\nescrita, MB\/s<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusionio_iodrive2_duo_mlc_application_accelerator_review\">Fusion-io ioDrive II DUO MLC<\/a><\/noindex><br \/>\n2.4<br \/>\n32.5<br \/>\n2.0 x8<br \/>\n480<br \/>\n490<br \/>\n3000<br \/>\n2500<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SANDISK FUSION IOMEMORY SX350-1300<\/a><\/noindex><br \/>\n1.3<br \/>\n4<br \/>\n2.0 x8<br \/>\n225<br \/>\n345<br \/>\n2800<br \/>\n1300<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_px600_review\">SANDISK FUSION IOMEMORY PX600-1300<\/a><\/noindex><br \/>\n1.3<br \/>\n16<br \/>\n2.0 x8<br \/>\n235<br \/>\n375<br \/>\n2700<br \/>\n1700<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SANDISK FUSION IOMEMORY SX350-1600<\/a><\/noindex><br \/>\n1.6<br \/>\n5.5<br \/>\n2.0 x8<br \/>\n270<br \/>\n375<br \/>\n2800<br \/>\n1700<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_sx300_review\">SanDisk Fusion ioMemory SX300-3200<\/a><\/noindex><br \/>\n3.2<br \/>\n11<br \/>\n2.0 x8<br \/>\n345<br \/>\n385<br \/>\n2700<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.sandisk.com\/content\/dam\/sandisk-main\/en_us\/assets\/resources\/enterprise\/data-sheets\/fusion-iomemory-sx350-pcie-application-accelerators-datasheet.pdf\">SanDisk Fusion ioMemory SX350-3200<\/a><\/noindex><br \/>\n3.2<br \/>\n11<br \/>\n2.0 x8<br \/>\n345<br \/>\n385<br \/>\n2800<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/fusion_iomemory_px600_review\">SANDISK FUSION IOMEMORY PX600<\/a><\/noindex><br \/>\n2.6<br \/>\n32<br \/>\n2.0 x8<br \/>\n350<br \/>\n385<br \/>\n2700<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/support.huawei.com\/enterprise\/en\/doc\/EDOC1000052593?section=j005\">Huawei ES3000 V2<\/a><\/noindex><br \/>\n1,6<br \/>\n8,76<br \/>\n2.0 x8<br \/>\n395<br \/>\n270<br \/>\n1550<br \/>\n1100<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/support.huawei.com\/enterprise\/en\/doc\/EDOC1000052593?section=j005\">Huawei ES3000 V2<\/a><\/noindex><br \/>\n3,2<br \/>\n17,52<br \/>\n2.0 x8<br \/>\n770<br \/>\n230<br \/>\n3100<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.emc.com\/collateral\/data-sheet\/h11411-xtremsf-ds.pdf\">EMC XtremSF<\/a><\/noindex><br \/>\n2,2<br \/>\n\u00a0<br \/>\n2.0 x8<br \/>\n340<br \/>\n110<br \/>\n2700<br \/>\n1000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/virident_flashmax_ii_mlc_application_accelerator_review_22tb\">HGST Virident FlashMAX II<\/a><\/noindex><br \/>\n2,2<br \/>\n33<br \/>\n2.0 x8<br \/>\n350<br \/>\n103<br \/>\n2700<br \/>\n1000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/documents.westerndigital.com\/\/content\/dam\/doc-library\/en_us\/assets\/public\/western-digital\/product\/hgst\/general-docs\/data-sheet-flashmax-pcie.pdf\">HGST Virident SSD FlashMAX II<\/a><\/noindex><br \/>\n4,8<br \/>\n10.1<br \/>\n2.0 x8<br \/>\n269<br \/>\n51<br \/>\n2600<br \/>\n900<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/documents.westerndigital.com\/\/content\/dam\/doc-library\/en_us\/assets\/public\/western-digital\/product\/hgst\/general-docs\/data-sheet-flashmax-pcie.pdf\">HGST Virident FlashMAX III<\/a><\/noindex><br \/>\n2,2<br \/>\n7.1<br \/>\n2.0 x8<br \/>\n531<br \/>\n59<br \/>\n2700<br \/>\n1400<\/p>\n<p>Dell Micron P420M<br \/>\n1.4<br \/>\n9.2<br \/>\n2.0 x8<br \/>\n750<br \/>\n95<br \/>\n3300<br \/>\n630<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.storagereview.com\/micron_p420m_enterprise_pcie_ssd_review\">Micron P420M<\/a><\/noindex><br \/>\n1.4<br \/>\n9.2<br \/>\n2.0 x8<br \/>\n750<br \/>\n95<br \/>\n3300<br \/>\n630<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.anandtech.com\/show\/10890\/hgst-ultrastar-sn200-accelerator-768-tb-capacity-61-gbs-read-speed-12m-iops\">HGST SN260<\/a><\/noindex><br \/>\n1.6<br \/>\n25.10<br \/>\n3.0 x8<br \/>\n1200<br \/>\n200<br \/>\n6170<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.anandtech.com\/show\/10890\/hgst-ultrastar-sn200-accelerator-768-tb-capacity-61-gbs-read-speed-12m-iops\">HGST SN260<\/a><\/noindex><br \/>\n3,2<br \/>\n17,52<br \/>\n3.0 x8<br \/>\n1200<br \/>\n200<br \/>\n6170<br \/>\n2200<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/ark.intel.com\/content\/www\/ru\/ru\/ark\/products\/88731\/intel-ssd-dc-p3608-series-1-6tb-1-2-height-pcie-3-0-x8-20nm-mlc.html\">Intel P3608<\/a><\/noindex><br \/>\n3,2<br \/>\n17,5<br \/>\n3.0 x8<br \/>\n850<br \/>\n80<br \/>\n4500<br \/>\n2600<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.kingston.com\/datasheets\/DCP1000_us.pdf\">Kingston DCP1000<\/a><\/noindex><br \/>\n3,2<br \/>\n2,78<br \/>\n3.0 x8<br \/>\n1000<br \/>\n180<br \/>\n6800<br \/>\n6000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/docs.oracle.com\/cd\/E65386_01\/html\/E65387\/gokdw.html#scrolltoc\">Oracle F320<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n750<br \/>\n120<br \/>\n5500<br \/>\n1800<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/global.semi.static\/PM1725_NVMe_PCIe_SSD_Samsung_2016-1.pdf\">Samsung PM1725<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n1000<br \/>\n120<br \/>\n6000<br \/>\n2000<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/ssd\/enterprise-ssd\/MZPLL3T2HMLS\/\">Samsung PM1725a<\/a><\/noindex><br \/>\n3.2<br \/>\n29<br \/>\n3.0 x8<br \/>\n1000<br \/>\n180<br \/>\n6200<br \/>\n2600<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.samsung.com\/semiconductor\/ssd\/enterprise-ssd\/MZPLL3T2HAJQ\/\">Samsung PM1725b<\/a><\/noindex><br \/>\n3.2<br \/>\n18<br \/>\n3.0 x8<br \/>\n980<br \/>\n180<br \/>\n6200<br \/>\n2600<\/p>\n<p>\n<img decoding=\"async\" alt=\"Atualiza\u00e7\u00e3o do subsistema de disco de um servidor antigo com barramento PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/369c72c6f028b915a199e85fc3de3819.jpg\" style=\"display:block;margin: 0 auto;\" \/>Entre esses SSDs, os Fusion ioMemory se destacam. O diretor cient\u00edfico <noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/Fusion-io\">Fusion<\/a><\/noindex> era <noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/%D0%92%D0%BE%D0%B7%D0%BD%D1%8F%D0%BA,_%D0%A1%D1%82%D0%B8%D0%B2\">Steve Wozniak<\/a><\/noindex>. Depois, essa empresa foi comprada pela SanDisk por 1,2 bilh\u00f5es de d\u00f3lares. Na \u00e9poca, custavam a partir de $50.000 cada. Atualmente, podem ser adquiridos por algumas centenas de d\u00f3lares em estado novo, com capacidade a partir de 1TB e mais.<\/p>\n<p>Se voc\u00ea observar a tabela, ver\u00e1 que eles t\u00eam um n\u00famero bastante alto de IOPS de grava\u00e7\u00e3o, praticamente igual ao n\u00famero de IOPS de leitura. Considerando seu pre\u00e7o atual, na minha opini\u00e3o, vale a pena prestar aten\u00e7\u00e3o nesses SSDs. <\/p>\n<p>No entanto, eles t\u00eam algumas particularidades:<\/p>\n<ol>\n<li>Eles n\u00e3o podem ser inicializ\u00e1veis.<\/li>\n<li>Um driver \u00e9 necess\u00e1rio para utiliza\u00e7\u00e3o. Existem drivers praticamente para tudo, mas para as vers\u00f5es mais recentes do Linux, ser\u00e1 necess\u00e1rio compilar.<\/li>\n<li>O tamanho de setor ideal para eles \u00e9 de 4096 bytes. (512 tamb\u00e9m \u00e9 suportado)<\/li>\n<li>O driver, no pior cen\u00e1rio, pode consumir uma quantidade consider\u00e1vel de RAM (com tamanho de setor de 512 bytes).<\/li>\n<li>O desempenho depende da velocidade do processador, portanto, tecnologias de economia de energia devem ser desativadas. Isso \u00e9 tanto uma vantagem quanto uma desvantagem, j\u00e1 que com um processador potente, o dispositivo pode operar at\u00e9 mais r\u00e1pido do que especificado nas especifica\u00e7\u00f5es.<\/li>\n<li>Requer um bom resfriamento. Isso n\u00e3o deve ser um problema para servidores.<\/li>\n<li>N\u00e3o \u00e9 recomendado para ESXi, pois o ESXi prefere discos com setor 512N, o que pode levar a um grande consumo de mem\u00f3ria pelo driver.<\/li>\n<li>Vers\u00f5es de marca desses SSDs geralmente n\u00e3o s\u00e3o suportadas por fornecedores at\u00e9 o n\u00edvel do \u00faltimo driver da SanDisk (mar\u00e7o de 2019).<\/li>\n<\/ol>\n<p>\nEu realizei testes com o Fusion ioMemory em compara\u00e7\u00e3o com um SSD servidor Intel P3700 PCI-E 3.0 x8 bastante moderno (o \u00faltimo custa cerca de 4 vezes mais do que o Fusion de capacidade similar). Al\u00e9m disso, tamb\u00e9m \u00e9 poss\u00edvel ver o quanto a velocidade \u00e9 reduzida devido \u00e0 conex\u00e3o x4.<\/p>\n<p>Fusion PX600 1.3TB PCI-E 2.0 x8<br \/>\nIntel P3700 1.6TB PCI-E 3.0 x4<\/p>\n<p><img decoding=\"async\" alt=\"Atualiza\u00e7\u00e3o do subsistema de disco de um servidor antigo com barramento PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/7157ec6e43cac87fc0cdf5dd2887cfac.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<img decoding=\"async\" alt=\"Atualiza\u00e7\u00e3o do subsistema de disco de um servidor antigo com barramento PCIe 1.0 \u2014 2.0\" src=\"\/wp-content\/uploads\/2019\/06\/f5db5f37b300332bd787d5b2fe57b67e.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>\nSim, a velocidade linear de leitura do Intel P3700 \u00e9 claramente limitada. No documento especifica que deve ser 2800 MB\/s, mas estamos obtendo apenas 1469 MB\/s. No entanto, de forma geral, pode-se afirmar que, com um barramento PCI-e 2.0, \u00e9 poss\u00edvel utilizar SSDs PCI-E 3.0 x4, se consegui-los a um pre\u00e7o razo\u00e1vel.<\/p>\n<h3>Como resultado, obtemos um servi\u00e7o de \"monitoramento como servi\u00e7o\", automatizado na linha de produ\u00e7\u00e3o de integra\u00e7\u00e3o cont\u00ednua. O desenvolvedor ou testador precisa apenas definir a lista de m\u00e9tricas em um arquivo JSON, e tudo o mais acontece automaticamente. Obtemos um controle de qualidade transparente dos lan\u00e7amentos: todas as notifica\u00e7\u00f5es sobre desempenho, consumo de recursos ou regress\u00f5es arquitet\u00f4nicas.<\/h3>\n<p>\nO subsistema de disco do servidor antigo com barramento PCI-E 1.0 ou 2.0 pode ser melhorado utilizando SSDs que conseguem aproveitar 8 linhas PCI-E, entregando uma capacidade de at\u00e9 4GB\/s (PCI-E 2.0) ou 2GB\/s (PCI-E 1.0). A op\u00e7\u00e3o mais econ\u00f4mica \u00e9 usar SSDs PCI-E 2.0 que j\u00e1 est\u00e3o um pouco obsoletos.<\/p>\n<p>Alternativas de compromisso tamb\u00e9m s\u00e3o simples de implementar, como a compra da chave CacheCade para controladores LSI ou a troca do controlador Adaptec por uma vers\u00e3o Q.<\/p>\n<p>E uma maneira completamente simples \u00e9 comprar um controlador RAID SATA III para que os SSDs funcionem em plena velocidade, aproveitando todo o potencial deles.<br \/>\n<br \/>Fonte: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/454222\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u041f\u043e\u0447\u0435\u043c\u0443 \u0442\u0435\u043c\u043e\u0439 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0432\u044b\u0431\u0440\u0430\u043d \u0430\u043f\u0433\u0440\u0435\u0439\u0434 \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b\u041f\u043e\u043d\u044f\u0442\u043d\u043e, \u0447\u0442\u043e \u0432 \u043f\u0435\u0440\u0432\u0443\u044e \u043e\u0447\u0435\u0440\u0435\u0434\u044c \u043d\u0443\u0436\u043d\u043e, \u043a\u0430\u043a \u043f\u0440\u0430\u0432\u0438\u043b\u043e: \u0423\u0432\u0435\u043b\u0438\u0447\u0438\u0442\u044c \u043e\u043f\u0435\u0440\u0430\u0442\u0438\u0432\u043d\u0443\u044e \u043f\u0430\u043c\u044f\u0442\u044c. \u042d\u0442\u043e \u043d\u0430\u0441\u0442\u043e\u043b\u044c\u043a\u043e \u043e\u0447\u0435\u0432\u0438\u0434\u043d\u044b\u0439 \u0445\u043e\u0434, \u0447\u0442\u043e \u044f \u0434\u0430\u0436\u0435 \u043d\u0435 \u0441\u0447\u0451\u043b \u043d\u0443\u0436\u043d\u044b\u043c \u043f\u0438\u0441\u0430\u0442\u044c \u043e\u0431 \u044d\u0442\u043e\u043c \u0432 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0435 \u041f\u043e\u0441\u0442\u0430\u0432\u0438\u0442\u044c \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440(\u044b) \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u043e\u0431\u0430 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u0430 \u043d\u0430 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0432\u0435\u0440\u0441\u0438\u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u044b\u0435 \u0441\u043e\u043a\u0435\u0442\u0430\u043c\u0438 \u0441\u0435\u0440\u0432\u0435\u0440\u0430. \u0414\u043b\u044f \u0441\u0442\u0430\u0440\u044b\u0445 \u0441\u0435\u0440\u0432\u0435\u0440\u043e\u0432, \u0447\u0442\u043e \u043f\u0430\u043c\u044f\u0442\u044c, \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u044b, \u043a\u0430\u043a [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":26262,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-34884","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.3 - aioseo.com -->\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"pt_PT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47Upgrade \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0442\u0430\u0440\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 \u0441 \u0448\u0438\u043d\u043e\u0439 PCIe 1.0 \u2014 2.0 | ProHoster\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:01:01+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:01:01+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Upgrade do subsistema de disco do servidor antigo com barramento PCIe 1.0 \u2014 2.0 | ProHoster","description":"","canonical_url":"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"pt_PT","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47Upgrade \u0434\u0438\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043e\u0434\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0442\u0430\u0440\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 \u0441 \u0448\u0438\u043d\u043e\u0439 PCIe 1.0 \u2014 2.0 | ProHoster","og:url":"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/upgrade-diskovoj-podsistemy-starogo-servera-s-shinoj-pcie-1-0-2-0","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:01:01+00:00","article:modified_time":"2019-10-31T19:01:01+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"34884","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-21 20:58:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 02:13:27","updated":"2026-01-21 20:58:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/posts\/34884","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/comments?post=34884"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/posts\/34884\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/media\/26262"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/media?parent=34884"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/categories?post=34884"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/tags?post=34884"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}