{"id":56401,"date":"2020-02-12T00:00:00","date_gmt":"2020-02-11T21:00:00","guid":{"rendered":"https:\/\/prohoster.info\/blog\/blog_prohoster\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit"},"modified":"2020-02-18T14:04:41","modified_gmt":"2020-02-18T11:04:41","slug":"besperebojniki-apc-smart-ups-i-kak-ih-gotovit","status":"publish","type":"post","link":"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","title":{"rendered":"No-breaks APC Smart UPS e como prepar\u00e1-los","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Entre a variedade de UPS, os Smart UPS da APC (atualmente \u2013 Schneider Electric) s\u00e3o os mais comuns em servidores de n\u00edvel inicial. A excelente confiabilidade e o baixo pre\u00e7o no mercado secund\u00e1rio fazem com que os administradores de sistema, sem pensar muito, encham os racks com esses UPS e tentem extrair ao m\u00e1ximo o lucro com equipamentos de 10 a 15 anos, apenas substituindo as baterias. Infelizmente, isso nem sempre traz o resultado esperado. Vamos analisar o que e como deve ser feito para que seu UPS funcione \"como novo\".<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<h3>Escolha de baterias<\/h3>\n<p>\nTodos os artigos e t\u00f3picos em f\u00f3runs sobre a escolha de baterias para UPS quase sempre lembram discuss\u00f5es sobre o tipo de \u00f3leo para motores de autom\u00f3veis\/motocicletas. Vamos tentar n\u00e3o nos assemelhar a eles, mas entender os princ\u00edpios b\u00e1sicos para a escolha de baterias, usando o fabricante CSB como exemplo. <\/p>\n<p>Vemos uma variedade de linhas de baterias: GP, GPL, HR, HRL, UPS, TPL. <\/p>\n<p>Come\u00e7amos a ler: GP, GPL \u2014 baterias de uso geral <b>para pequenos e m\u00e9dios n\u00edveis de descarga.<\/b>. Recomendados para uso em sistemas de seguran\u00e7a e combate a inc\u00eandios e UPS. N\u00e3o nos servem. Embora sejam os mais comprados, frequentemente sem que as suas caracter\u00edsticas sejam estudadas. <\/p>\n<p><img decoding=\"async\" alt=\"No-breaks APC Smart UPS e como prepar\u00e1-los\" src=\"\/wp-content\/uploads\/2020\/02\/8daafaf7943d755075773d981e84d94c.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nA s\u00e9rie HR \u2014 baterias de maior capacidade e que permitem descarga profunda (at\u00e9 11% de capacidade residual), especialmente \u00fateis quando grandes correntes de descarga s\u00e3o necess\u00e1rias. A diferen\u00e7a das baterias \"H\" \u00e9 uma grade especial que aumenta a pot\u00eancia de sa\u00edda em 20%. Elas se adaptam melhor a aplica\u00e7\u00f5es em instala\u00e7\u00f5es de energia potentes e UPS.<\/p>\n<p>A letra \"L\" na s\u00e9rie indica que estas s\u00e3o baterias de vida \u00fatil prolongada (Long Life), em modo de opera\u00e7\u00e3o em buffer, com at\u00e9 10 anos de dura\u00e7\u00e3o.<\/p>\n<p>E a s\u00e9rie UPS \u2014 \u00e9 uma bateria especialmente projetada para opera\u00e7\u00e3o em altas correntes com tempos de descarga curtos.<\/p>\n<p>Eu demorei para escolher entre UPS e HRL, mas decidi pegar a HRL. Infelizmente, dizer como elas se comportar\u00e3o em longo prazo s\u00f3 ser\u00e1 poss\u00edvel em 5 anos, e necropostagens n\u00e3o s\u00e3o bem vistas. Portanto, vou considerar isso minha escolha pessoal e n\u00e3o pretendo imp\u00f4-la. Mas voc\u00ea deve entender que \u00e9 necess\u00e1rio escolher baterias de alta corrente, pois elas devem ser capazes de liberar toda a capacidade acumulada em 20-30 minutos. <\/p>\n<h3>Selecionando o conjunto de baterias<\/h3>\n<p>\nConsiderando que na montagem s\u00e3o utilizadas v\u00e1rias baterias, \u00e9 altamente recomend\u00e1vel que elas possuam caracter\u00edsticas id\u00eanticas. Um \u00fanico acumulador de qualidade ruim far\u00e1 com que toda a montagem funcione de maneira diferente do esperado.<\/p>\n<p>H\u00e1 cerca de 5 anos, descobri a empresa de Rostov \"Bastion\", que fabrica testadores de capacidade de bateria sob a marca \"Skat\". N\u00e3o afirmo que a precis\u00e3o das medi\u00e7\u00f5es de capacidade \u00e9 perfeita, mas para avaliar o n\u00edvel: ideal-vivo-ainda serve-cad\u00e1ver, este testador \u00e9 mais do que suficiente. <\/p>\n<p><img decoding=\"async\" alt=\"No-breaks APC Smart UPS e como prepar\u00e1-los\" src=\"\/wp-content\/uploads\/2020\/02\/7390b5c6865ebe74998c6d6494c4e548.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nEm princ\u00edpio, \u00e9 poss\u00edvel medir a capacidade de forma banal, descarregando e carregando com o uso de um cron\u00f4metro, uma l\u00e2mpada automotiva de 21W (que oferece uma carga de cerca de 1A) e um testador, mas isso \u00e9 demorado e muitas vezes d\u00e1 pregui\u00e7a.<\/p>\n<p>Em \u00faltimo caso, tentamos apenas usar baterias novas da mesma remessa e torcer para que voc\u00ea tenha sorte. <\/p>\n<h3>Eletricidade \u00e9 a ci\u00eancia dos contatos.<\/h3>\n<p>\nUm mau contato em uma montagem de 4 baterias anular\u00e1 todos os seus esfor\u00e7os, portanto desmontamos a montagem com extremo cuidado. Normalmente, em UPSs, s\u00e3o utilizados conectores para baterias com fechos, que podem facilmente ser danificados apenas puxando-os. Portanto, pegamos uma pequena chave de fenda, inserimos no conector como na foto e a removemos com cuidado, sem fazer for\u00e7a excessiva. Como sugeriu um colega nos coment\u00e1rios \u2014 basta puxar pela capa pl\u00e1stica, e n\u00e3o pelo fio. O conector se solta com um leve estalo.<\/p>\n<p><img decoding=\"async\" alt=\"No-breaks APC Smart UPS e como prepar\u00e1-los\" src=\"\/wp-content\/uploads\/2020\/02\/07d704acf5b9c5a92b2ddf6e05f89f2a.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nBem, quanto \u00e0 conex\u00e3o correta dos fios, acho que n\u00e3o \u00e9 necess\u00e1rio explicar demais. Se voc\u00ea abriu o UPS, certamente j\u00e1 conhece o princ\u00edpio de conex\u00e3o em s\u00e9rie das baterias. E para os demais: papel e caneta ou smartphone com c\u00e2mera. Ap\u00f3s a montagem, por precau\u00e7\u00e3o, medimos a voltagem da montagem com um testador e comparamos com o que deveria ser, com base na quantidade de baterias.<\/p>\n<h3>\"Eu fiz tudo conforme escrito, mas n\u00e3o ajudou\"<\/h3>\n<p>\nAgora come\u00e7a a parte mais interessante. O UPS, durante seu funcionamento, periodicamente (geralmente a cada 7 ou 14 dias, dependendo da configura\u00e7\u00e3o) realiza uma breve calibra\u00e7\u00e3o da bateria. Ele muda para o modo de opera\u00e7\u00e3o a partir da bateria e mede a tens\u00e3o imediatamente e ap\u00f3s um curto per\u00edodo. O resultado disso \u00e9 um certo coeficiente de corre\u00e7\u00e3o de \"vida da bateria\", que ele registra. \u00c0 medida que a bateria vai se deteriorando, o estado desse registro diminui gradualmente. Com base nele, o UPS calcula o tempo restante de opera\u00e7\u00e3o a partir da bateria. E ent\u00e3o, em um belo dia, percebendo que a situa\u00e7\u00e3o \u00e9 cr\u00edtica, o UPS acende o indicador pedindo a substitui\u00e7\u00e3o da bateria. Mas, quando fazemos a substitui\u00e7\u00e3o, o UPS n\u00e3o sabe disso! O estado do registro \"vida da bateria\" permanece o mesmo. Precisamos corrigi-lo.<\/p>\n<p>Existem duas op\u00e7\u00f5es aqui. A primeira, simples e r\u00e1pida \u2013 \u00e9 necess\u00e1rio realizar uma calibra\u00e7\u00e3o completa do UPS. Para isso, precisa-se carreg\u00e1-lo com mais de 35% e iniciar a calibra\u00e7\u00e3o, por exemplo, a partir do programa PowerChute. Isso funciona em cerca de metade dos casos. Por que n\u00e3o funciona sempre \u2013 \u00e9 um mist\u00e9rio. Portanto, vamos pelo caminho mais longo, mas mais confi\u00e1vel.<\/p>\n<p>Precisamos de: um computador com porta COM, um cabo original (por exemplo, 940-0024\u0421), o programa UpsDiag 2.0 (para a seguran\u00e7a do seu UPS, um colega recomenda usar melhor o apcfix no modo gratuito. N\u00e3o posso dizer muito sobre isso, al\u00e9m de que recomendo categoricamente n\u00e3o clicar em nada al\u00e9m da corre\u00e7\u00e3o do registro 0 no UpsDiag. <i>especialmente o bot\u00e3o de corre\u00e7\u00e3o autom\u00e1tica de erros da bateria<\/i>) e <noindex><a rel=\"nofollow\" href=\"http:\/\/www.apcupsd.com\/manual\/manual.html#configuring-your-eeprom\">tabela de valores de calibra\u00e7\u00e3o<\/a><\/noindex>. Estamos interessados no valor do registro 0. Na tabela, o valor \u00e9 indicado para baterias ideais, esf\u00e9ricas e no v\u00e1cuo. Quaisquer baterias reais dar\u00e3o ap\u00f3s a calibra\u00e7\u00e3o um valor menor, mas n\u00e3o muito.<\/p>\n<p><img decoding=\"async\" alt=\"No-breaks APC Smart UPS e como prepar\u00e1-los\" src=\"\/wp-content\/uploads\/2020\/02\/93542115e332bece7803efac1c88a284.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nPor exemplo, vamos pegar um UPS real SUA1500RMI2U. No momento da substitui\u00e7\u00e3o da bateria, o UpsDiag mostrava o valor do registro 0 \u2013 42. Ou seja, as baterias est\u00e3o mortas. O valor de calibra\u00e7\u00e3o da tabela \u00e9 A1. <\/p>\n<p>Vamos come\u00e7ar a corrigir. Primeiro de tudo <b>desconectamos a placa de rede do UPS<\/b>. A presen\u00e7a da placa de rede n\u00e3o permitir\u00e1 que voc\u00ea corrija o registro. Por que \u2013 \u00e9 uma quest\u00e3o para os engenheiros da APC. Felizmente, voc\u00ea pode remov\u00ea-la com o UPS ligado. <\/p>\n<p>Conectamos o cabo, iniciamos o UpsDiag, vamos para a aba \"Calibra\u00e7\u00e3o\" e verificamos o estado do registro 0. Anotamos em um papel, clicamos com o bot\u00e3o direito sobre ele \u2013 Alterar. Levantamos seu valor at\u00e9 o valor da tabela de calibra\u00e7\u00f5es \u2013 A1. Se na tabela n\u00e3o houver seu UPS, em princ\u00edpio, \u00e9 poss\u00edvel elevar at\u00e9 FF. Isso n\u00e3o causa problemas, exceto para um UPS surpreso, que mostrar\u00e1 que est\u00e1 pronto para suportar a carga at\u00e9 a segunda vinda. <\/p>\n<p>Em seguida, precisamos esperar a carga da bateria at\u00e9 100%, sobrecarregar o UPS at\u00e9 35% ou um pouco mais e iniciar a calibra\u00e7\u00e3o. Ap\u00f3s a calibra\u00e7\u00e3o, olhamos novamente o valor no registro 0 e comparamos com o anotado no papel. No SUA1500RMI2U mencionado acima, com novas baterias HRL1234W, o valor tornou-se \u2013 98, que, na verdade, n\u00e3o est\u00e1 muito longe do valor de calibra\u00e7\u00e3o A1.<\/p>\n<p>Depois de tudo, deixamos carregar novamente at\u00e9 100%, retiramos o cabo COM, conectamos de volta a placa de rede e desejamos ao UPS uma longa e feliz vida em prol do nosso rack de servidores.<\/p>\n<p>A prop\u00f3sito, as placas de rede, como a AP9619, tamb\u00e9m ca\u00edram de pre\u00e7o no mercado de segunda m\u00e3o at\u00e9 valores inaceit\u00e1veis. Mas como prepar\u00e1-las (reset de senha, atualiza\u00e7\u00e3o de firmware, configura\u00e7\u00e3o) \u2013 isso \u00e9 assunto para um artigo separado.<br \/>\n<br \/>Fonte: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/487802\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric). \u0412\u0435\u043b\u0438\u043a\u043e\u043b\u0435\u043f\u043d\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0438\u0437\u043a\u0430\u044f \u0446\u0435\u043d\u0430 \u043d\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u043c \u0440\u044b\u043d\u043a\u0435, \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u044e\u0442 \u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u0441\u0438\u0441\u0430\u0434\u043c\u0438\u043d\u044b, \u043e\u0441\u043e\u0431\u043e \u043d\u0435 \u0437\u0430\u0434\u0443\u043c\u044b\u0432\u0430\u044f\u0441\u044c, \u0443\u0442\u044b\u043a\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u043e\u0439\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u043c\u0438 \u0418\u0411\u041f \u0438 \u043f\u044b\u0442\u0430\u044e\u0442\u0441\u044f \u0432\u044b\u0442\u044f\u043d\u0443\u0442\u044c \u0441 \u0436\u0435\u043b\u0435\u0437\u043e\u043a 10-15 \u043b\u0435\u0442\u043d\u0435\u0439 \u0434\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0443\u043c \u043f\u0440\u043e\u0444\u0438\u0442\u0430 \u0431\u0430\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u043e\u0439 \u0430\u043a\u043a\u0443\u043c\u0443\u043b\u044f\u0442\u043e\u0440\u043e\u0432. \u041a \u0441\u043e\u0436\u0430\u043b\u0435\u043d\u0438\u044e \u043d\u0435 \u0432\u0441\u0435\u0433\u0434\u0430 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-56401","post","type-post","status-publish","format-standard","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.3 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"pt_PT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-02-11T21:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-02-18T11:04:41+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47UPS APC Smart, e como prepar\u00e1-los | ProHoster","description":"Dentre a vasta gama de UPS, os mais comuns em servidores de n\u00edvel inicial s\u00e3o os Smart UPS da APC (atualmente \u2013 Schneider Electric).","canonical_url":"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"pt_PT","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster","og:description":"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).","og:url":"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-02-11T21:00:00+00:00","article:modified_time":"2020-02-18T11:04:41+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"56401","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 19:25:39","updated":"2022-09-29 13:07:34","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/posts\/56401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/comments?post=56401"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/posts\/56401\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/media?parent=56401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/categories?post=56401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/tags?post=56401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}