{"id":87278,"date":"2020-07-06T13:44:46","date_gmt":"2020-07-06T11:44:46","guid":{"rendered":"https:\/\/prohoster.info\/blog\/administrirovanie\/sistemy-izolyaczii-vozdushnyh-koridorov-czod-chast-2-holodnye-i-goryachie-koridory-kakoj-izoliruem"},"modified":"2020-07-06T13:44:46","modified_gmt":"2020-07-06T11:44:46","slug":"sistemy-izolyaczii-vozdushnyh-koridorov-czod-chast-2-holodnye-i-goryachie-koridory-kakoj-izoliruem","status":"publish","type":"post","link":"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/sistemy-izolyaczii-vozdushnyh-koridorov-czod-chast-2-holodnye-i-goryachie-koridory-kakoj-izoliruem","title":{"rendered":"Sistemas de isolamento de corredores de ar de data centers. Parte 2. Corredores frios e quentes. Qual isolar?","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Existem duas op\u00e7\u00f5es para a instala\u00e7\u00e3o de um sistema de conten\u00e7\u00e3o em um data center em funcionamento (sobre a instala\u00e7\u00e3o de sistemas de conten\u00e7\u00e3o em data centers em constru\u00e7\u00e3o, falarei na pr\u00f3xima parte). No primeiro caso, isolamos o corredor frio, e no segundo, o corredor quente. Cada uma das op\u00e7\u00f5es tem suas caracter\u00edsticas, vantagens e desvantagens. <\/p>\n<p><\/p>\n<h4>Isolamento do corredor frio<\/h4>\n<p><\/p>\n<p>Princ\u00edpio de funcionamento: para fornecer o fluxo de ar frio no corredor, s\u00e3o utilizados pain\u00e9is perfurados, instalados em frente \u00e0 porta frontal do rack. O ar quente \u00e9 'expelido' para o espa\u00e7o geral do ambiente.<\/p>\n<p>\n<img decoding=\"async\" alt=\"Sistemas de isolamento de corredores de ar de data centers. Parte 2. Corredores frios e quentes. Qual isolar?\" src=\"\/wp-content\/uploads\/2020\/07\/f6bd1710e7c0329ad399bf28c2577e9f.jpg\" style=\"display:block;margin: 0 auto;\" \/><noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<p>Instala\u00e7\u00e3o de racks: para isolar o corredor frio, os condicionadores de ar para racks s\u00e3o posicionados ao longo do per\u00edmetro do ambiente e sopram o fluxo de ar frio sob o falso piso. Os racks s\u00e3o instalados em fileira, de frente um para o outro. <\/p>\n<p><\/p>\n<p>Acesso direto aos sistemas de cabos transpac\u00edficos. Ping m\u00ednimo para a China, Jap\u00e3o, Austr\u00e1lia e costa oeste dos EUA.<\/p>\n<p><\/p>\n<ul>\n<li>custo relativamente baixo, <\/li>\n<li>facilidade de escalabilidade: o condicionador de ar para racks pode ser instalado em qualquer lugar livre ao longo do per\u00edmetro do data center.<\/li>\n<\/ul>\n<p><\/p>\n<p>Pontos negativos: <\/p>\n<p><\/p>\n<ul>\n<li>dificuldade de escalabilidade: em v\u00e1rios corredores, podem surgir problemas com a uniformidade do fornecimento de ar para diferentes filas, <\/li>\n<li>no caso de equipamentos de alta carga, \u00e9 dif\u00edcil aumentar a entrega local do fluxo de ar frio, pois \u00e9 necess\u00e1rio instalar placas perfuradas adicionais no falso piso,<\/li>\n<li>condi\u00e7\u00f5es de trabalho n\u00e3o muito confort\u00e1veis para o pessoal, uma vez que todo o ambiente est\u00e1 na zona quente.<\/li>\n<\/ul>\n<p><\/p>\n<p>Caracter\u00edsticas construtivas: <\/p>\n<p><\/p>\n<ul>\n<li>\u00e9 necess\u00e1rio um espa\u00e7o adicional em altura para a instala\u00e7\u00e3o do falso piso e um espa\u00e7o adicional para a instala\u00e7\u00e3o de uma rampa na entrada,<\/li>\n<li>j\u00e1 que o cont\u00eainer \u00e9 isolado ao longo do per\u00edmetro interno do corredor, \u00e9 necess\u00e1ria a isola\u00e7\u00e3o da frente do rack e um plug de soquete sob o rack na frente. <\/li>\n<\/ul>\n<p><\/p>\n<p>Para quem \u00e9 adequado: pequenas salas de servidores ou data centers com baixa carga (at\u00e9 5 kW por rack). <\/p>\n<p><\/p>\n<h4>Corredor quente<\/h4>\n<p><\/p>\n<p>Princ\u00edpio de funcionamento: no caso do isolamento do corredor quente, s\u00e3o utilizados condicionadores de ar interleaved, que sopram o fluxo de ar frio para o espa\u00e7o geral do ambiente. <\/p>\n<p>\n<img decoding=\"async\" alt=\"Sistemas de isolamento de corredores de ar de data centers. Parte 2. Corredores frios e quentes. Qual isolar?\" src=\"\/wp-content\/uploads\/2020\/07\/b38da4a5ff981f13521bfc3aa419717e.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>Instala\u00e7\u00e3o de racks: os arm\u00e1rios s\u00e3o instalados em filas, com as costas voltadas um para o outro. Nesse caso, os condicionadores de ar s\u00e3o instalados em uma \u00fanica linha com os arm\u00e1rios para minimizar o comprimento do fluxo de ar, aumentando assim a efici\u00eancia do sistema de refrigera\u00e7\u00e3o. O ar quente \u00e9 expelido para um recipiente fechado e depois retorna para o condicionador. <\/p>\n<p><\/p>\n<p>Acesso direto aos sistemas de cabos transpac\u00edficos. Ping m\u00ednimo para a China, Jap\u00e3o, Austr\u00e1lia e costa oeste dos EUA.<\/p>\n<p><\/p>\n<ul>\n<li>uma solu\u00e7\u00e3o confi\u00e1vel e eficiente que pode ser utilizada com racks de alta carga, bem como em ambientes com teto baixo, pois sua instala\u00e7\u00e3o n\u00e3o requer piso falso nem plenum superior.<\/li>\n<li>escalabilidade f\u00e1cil, pois cada corredor \u00e9 independente. <\/li>\n<li>conforto para a equipe no ambiente.<\/li>\n<\/ul>\n<p><\/p>\n<p>Pontos negativos: <\/p>\n<p><\/p>\n<ul>\n<li>pre\u00e7o: nesta op\u00e7\u00e3o, s\u00e3o necess\u00e1rios mais condicionadores de ar, sendo que cada recipiente requer seu pr\u00f3prio condicionador de ar de reserva. <\/li>\n<li>os condicionadores de ar inter-racks ocupam espa\u00e7o que poderia ser utilizado para arm\u00e1rios de servidores. <\/li>\n<li>dificuldades de escalabilidade: a adi\u00e7\u00e3o de condicionadores de ar s\u00f3 \u00e9 poss\u00edvel se pontos de conex\u00e3o adicionais forem previstos com anteced\u00eancia.<\/li>\n<\/ul>\n<p><\/p>\n<p>Caracter\u00edsticas construtivas: <\/p>\n<p><\/p>\n<ul>\n<li>o ambiente n\u00e3o requer reserva adicional de altura. <\/li>\n<li>o pr\u00f3prio recipiente \u00e9 isolado ao longo do per\u00edmetro externo do corredor.<\/li>\n<li>nos arm\u00e1rios, \u00e9 necess\u00e1rio isolar a frente e usar um rodap\u00e9, bem como isolar todas as tampas dos arm\u00e1rios.<\/li>\n<li>para os arm\u00e1rios de extremidade do corredor, \u00e9 necess\u00e1ria a isolamento das laterais do arm\u00e1rio e do rodap\u00e9 ao longo do per\u00edmetro externo. <\/li>\n<\/ul>\n<p>\n<img decoding=\"async\" alt=\"Sistemas de isolamento de corredores de ar de data centers. Parte 2. Corredores frios e quentes. Qual isolar?\" src=\"\/wp-content\/uploads\/2020\/07\/20e3b9b156b05f090fec6fe5e5bca397.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>Para quem \u00e9 adequado: salas de servidores pequenas e m\u00e9dias com alta carga (at\u00e9 10 kW por rack). <\/p>\n<p><\/p>\n<h4>Caso particular: sistemas de conten\u00e7\u00e3o de arm\u00e1rios com circuito de refrigera\u00e7\u00e3o fechado. <\/h4>\n<p><\/p>\n<p>Princ\u00edpio de funcionamento: os condicionadores de ar s\u00e3o instalados pr\u00f3ximos aos arm\u00e1rios ou dentro deles, formando zonas fechadas de calor e frio. A troca de ar ocorre dentro do arm\u00e1rio (ou de um pequeno grupo de arm\u00e1rios). <\/p>\n<p><\/p>\n<p>Acesso direto aos sistemas de cabos transpac\u00edficos. Ping m\u00ednimo para a China, Jap\u00e3o, Austr\u00e1lia e costa oeste dos EUA.<\/p>\n<p><\/p>\n<ul>\n<li>solu\u00e7\u00e3o de alto desempenho, aplic\u00e1vel a racks sobrecarregados ou em ambientes n\u00e3o projetados para equipamentos de TI (o recipiente tamb\u00e9m exerce a fun\u00e7\u00e3o de prote\u00e7\u00e3o para o equipamento de TI). <\/li>\n<li>pode ser usado em ambientes com teto baixo. <\/li>\n<\/ul>\n<p><\/p>\n<p>Pontos negativos:<\/p>\n<p><\/p>\n<ul>\n<li>alto custo da solu\u00e7\u00e3o impede a coloca\u00e7\u00e3o em massa de arm\u00e1rios.<\/li>\n<li>capacidade de escalabilidade limitada: para garantir a redund\u00e2ncia para cada conjunto, \u00e9 necess\u00e1rio um ar-condicionado separado. <\/li>\n<li>complexidade do sistema de combate a inc\u00eandios: cada arm\u00e1rio fechado se torna um compartimento separado, necessitando de seu pr\u00f3prio conjunto de sensores de monitoramento e de um sistema local para combate a inc\u00eandios.<\/li>\n<\/ul>\n<p><\/p>\n<p>Caracter\u00edsticas construtivas: <\/p>\n<p><\/p>\n<ul>\n<li>o ambiente n\u00e3o requer reserva adicional de altura. <\/li>\n<li>a estrutura do arm\u00e1rio prev\u00ea um contorno completamente fechado, incluindo a possibilidade de prote\u00e7\u00e3o por IP. <\/li>\n<\/ul>\n<p><\/p>\n<p>Para quem \u00e9 adequado: para aqueles que precisam acomodar complexos de computa\u00e7\u00e3o de alta carga (at\u00e9 20 kW por rack).<\/p>\n<p>Fonte: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/509448\/\">habr.com<\/a> <\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442 \u0434\u0432\u0430 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u0430 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u0438\u0437\u0430\u0446\u0438\u0438 \u0432 \u0443\u0436\u0435 \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0435\u043c \u043c\u0430\u0448\u0437\u0430\u043b\u0435 (\u043f\u0440\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0443 \u0441\u0438\u0441\u0442\u0435\u043c \u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u0441\u0442\u0440\u043e\u044f\u0449\u0438\u0445\u0441\u044f \u043c\u0430\u0448\u0437\u0430\u043b\u0430\u0445 \u0440\u0430\u0441\u0441\u043a\u0430\u0436\u0443 \u0432 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u0439 \u0447\u0430\u0441\u0442\u0438). \u0412 \u043f\u0435\u0440\u0432\u043e\u043c \u0441\u043b\u0443\u0447\u0430\u0435 \u0438\u0437\u043e\u043b\u0438\u0440\u0443\u0435\u043c \u0445\u043e\u043b\u043e\u0434\u043d\u044b\u0439, \u0430 \u0432\u043e \u0432\u0442\u043e\u0440\u043e\u043c \u2013 \u0433\u043e\u0440\u044f\u0447\u0438\u0439 \u043a\u043e\u0440\u0438\u0434\u043e\u0440. \u041a\u0430\u0436\u0434\u044b\u0439 \u0438\u0437 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u043e\u0432 \u0438\u043c\u0435\u0435\u0442 \u0441\u0432\u043e\u0438 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u0438, \u043f\u043b\u044e\u0441\u044b \u0438 \u043c\u0438\u043d\u0443\u0441\u044b. \u0418\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0445\u043e\u043b\u043e\u0434\u043d\u043e\u0433\u043e \u043a\u043e\u0440\u0438\u0434\u043e\u0440\u0430 \u041f\u0440\u0438\u043d\u0446\u0438\u043f \u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f: \u0434\u043b\u044f \u043f\u043e\u0434\u0430\u0447\u0438 \u0445\u043e\u043b\u043e\u0434\u043d\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430 \u0432\u043e\u0437\u0434\u0443\u0445\u0430 \u0432 \u043a\u043e\u0440\u0438\u0434\u043e\u0440 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u043f\u0435\u0440\u0444\u043e\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":87279,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-87278","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.3 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442 \u0434\u0432\u0430 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u0430 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u0438\u0437\u0430\u0446\u0438\u0438 \u0432 \u0443\u0436\u0435 \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0435\u043c \u043c\u0430\u0448\u0437\u0430\u043b\u0435 (\u043f\u0440\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0443 \u0441\u0438\u0441\u0442\u0435\u043c \u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u0441\u0442\u0440\u043e\u044f\u0449\u0438\u0445\u0441\u044f \u043c\u0430\u0448\u0437\u0430\u043b\u0430\u0445 \u0440\u0430\u0441\u0441\u043a\u0430\u0436\u0443 \u0432 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u0439 \u0447\u0430\u0441\u0442\u0438).\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/sistemy-izolyaczii-vozdushnyh-koridorov-czod-chast-2-holodnye-i-goryachie-koridory-kakoj-izoliruem\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"pt_PT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0445 \u043a\u043e\u0440\u0438\u0434\u043e\u0440\u043e\u0432 \u0426\u041e\u0414. \u0427\u0430\u0441\u0442\u044c 2. \u0425\u043e\u043b\u043e\u0434\u043d\u044b\u0435 \u0438 \u0433\u043e\u0440\u044f\u0447\u0438\u0435 \u043a\u043e\u0440\u0438\u0434\u043e\u0440\u044b. \u041a\u0430\u043a\u043e\u0439 \u0438\u0437\u043e\u043b\u0438\u0440\u0443\u0435\u043c? | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442 \u0434\u0432\u0430 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u0430 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u0438\u0437\u0430\u0446\u0438\u0438 \u0432 \u0443\u0436\u0435 \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0435\u043c \u043c\u0430\u0448\u0437\u0430\u043b\u0435 (\u043f\u0440\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0443 \u0441\u0438\u0441\u0442\u0435\u043c \u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u0441\u0442\u0440\u043e\u044f\u0449\u0438\u0445\u0441\u044f \u043c\u0430\u0448\u0437\u0430\u043b\u0430\u0445 \u0440\u0430\u0441\u0441\u043a\u0430\u0436\u0443 \u0432 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u0439 \u0447\u0430\u0441\u0442\u0438).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/sistemy-izolyaczii-vozdushnyh-koridorov-czod-chast-2-holodnye-i-goryachie-koridory-kakoj-izoliruem\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-07-06T11:44:46+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-07-06T11:44:46+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Sistemas de isolamento de corredores de ar em Data Centers. Parte 2. Corredores frios e quentes. Qual isolar? | ProHoster","description":"Existem duas op\u00e7\u00f5es de instala\u00e7\u00e3o do sistema de conten\u00e7\u00e3o em uma sala de m\u00e1quinas j\u00e1 em opera\u00e7\u00e3o (a instala\u00e7\u00e3o de sistemas de isolamento em salas de m\u00e1quinas em constru\u00e7\u00e3o ser\u00e1 abordada na pr\u00f3xima parte).","canonical_url":"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/sistemy-izolyaczii-vozdushnyh-koridorov-czod-chast-2-holodnye-i-goryachie-koridory-kakoj-izoliruem","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"pt_PT","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0445 \u043a\u043e\u0440\u0438\u0434\u043e\u0440\u043e\u0432 \u0426\u041e\u0414. \u0427\u0430\u0441\u0442\u044c 2. \u0425\u043e\u043b\u043e\u0434\u043d\u044b\u0435 \u0438 \u0433\u043e\u0440\u044f\u0447\u0438\u0435 \u043a\u043e\u0440\u0438\u0434\u043e\u0440\u044b. \u041a\u0430\u043a\u043e\u0439 \u0438\u0437\u043e\u043b\u0438\u0440\u0443\u0435\u043c? | ProHoster","og:description":"\u0421\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442 \u0434\u0432\u0430 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u0430 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043a\u043e\u043d\u0442\u0435\u0439\u043d\u0435\u0440\u0438\u0437\u0430\u0446\u0438\u0438 \u0432 \u0443\u0436\u0435 \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0435\u043c \u043c\u0430\u0448\u0437\u0430\u043b\u0435 (\u043f\u0440\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0443 \u0441\u0438\u0441\u0442\u0435\u043c \u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u0441\u0442\u0440\u043e\u044f\u0449\u0438\u0445\u0441\u044f \u043c\u0430\u0448\u0437\u0430\u043b\u0430\u0445 \u0440\u0430\u0441\u0441\u043a\u0430\u0436\u0443 \u0432 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u0439 \u0447\u0430\u0441\u0442\u0438).","og:url":"https:\/\/prohoster.info\/pt\/blog\/administrirovanie\/sistemy-izolyaczii-vozdushnyh-koridorov-czod-chast-2-holodnye-i-goryachie-koridory-kakoj-izoliruem","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-07-06T11:44:46+00:00","article:modified_time":"2020-07-06T11:44:46+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"87278","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 13:55:30","updated":"2022-09-29 11:38:42","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/posts\/87278","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/comments?post=87278"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/posts\/87278\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/media\/87279"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/media?parent=87278"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/categories?post=87278"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/pt\/wp-json\/wp\/v2\/tags?post=87278"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}