{"id":56401,"date":"2020-02-12T00:00:00","date_gmt":"2020-02-11T21:00:00","guid":{"rendered":"https:\/\/prohoster.info\/blog\/blog_prohoster\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit"},"modified":"2020-02-18T14:04:41","modified_gmt":"2020-02-18T11:04:41","slug":"besperebojniki-apc-smart-ups-i-kak-ih-gotovit","status":"publish","type":"post","link":"https:\/\/prohoster.info\/ro\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","title":{"rendered":"UPS-uri APC Smart, \u0219i cum s\u0103 le preg\u0103ti\u021bi","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Dintre toat\u0103 diversitatea UPS-urilor, cele mai comune \u00een serverele de nivel de baz\u0103 sunt Smart UPS de la APC (acum \u2013 Schneider Electric). Fiabilitatea excelent\u0103 \u0219i pre\u021bul sc\u0103zut pe pia\u021ba secundar\u0103 \u00eei determin\u0103 pe administratorii de sistem s\u0103 foloseasc\u0103 aceste UPS-uri \u00een rack-uri, \u00eencerc\u00e2nd s\u0103 extrag\u0103 maximum de profit din echipamente vechi de 10-15 ani prin simpla \u00eenlocuire a bateriilor. Din p\u0103cate, aceasta nu ofer\u0103 \u00eentotdeauna rezultatele a\u0219teptate. Vom \u00eencerca s\u0103 \u00een\u021belegem ce \u0219i cum ar trebui s\u0103 facem pentru ca UPS-ul dvs. s\u0103 func\u021bioneze \u201eca nou\u201d.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<h3>Alegerea bateriilor<\/h3>\n<p>\nToate articolele \u0219i subiectele de pe forumuri privind alegerea bateriilor pentru UPS, adesea amintesc de discu\u021biile despre alegerea uleiului de motor pentru ma\u0219ini\/motoare. Vom \u00eencerca s\u0103 nu ne l\u0103s\u0103m influen\u021ba\u021bi de acestea, ci s\u0103 \u00een\u021belegem principiile de baz\u0103 ale alegerii bateriilor prin exemplul produc\u0103torului CSB. <\/p>\n<p>Observ\u0103m c\u0103 au multe linii diferite de baterii: GP, GPL, HR, HRL, UPS, TPL. <\/p>\n<p>\u00cencepem s\u0103 citim: GP, GPL \u2014 baterii de utilizare universal\u0103 <b>pentru curen\u021bi mici \u0219i medii de desc\u0103rcare.<\/b>Recomandate pentru utilizare \u00een sisteme de securitate \u0219i incendiu \u0219i UPS-uri. Nu ne sunt potrivite. De\u0219i acestea sunt cele mai frecvent cump\u0103rate, f\u0103r\u0103 a studia caracteristicile lor. <\/p>\n<p><img decoding=\"async\" alt=\"UPS-uri APC Smart, \u0219i cum s\u0103 le preg\u0103ti\u021bi\" src=\"\/wp-content\/uploads\/2020\/02\/8daafaf7943d755075773d981e84d94c.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nSeria HR \u2014 baterii cu capacitate energetic\u0103 mare \u0219i care permit desc\u0103rc\u0103ri ad\u00e2nci (p\u00e2n\u0103 la 11% capacitate rezidual\u0103), fiind deosebit de utile \u00een cazul necesit\u0103\u021bii unor curen\u021bi mari de desc\u0103rcare. Diferen\u021ba dintre bateriile \u201eH\u201d const\u0103 \u00eentr-o structur\u0103 special\u0103 a grilei, care permite cre\u0219terea puterii de ie\u0219ire cu 20%. Acestea se potrivesc cel mai bine pentru utilizarea \u00een unit\u0103\u021bi energetice puternice \u0219i UPS-uri.<\/p>\n<p>Litera \u201eL\u201d din serie indic\u0103 faptul c\u0103 acestea sunt baterii cu o durat\u0103 de via\u021b\u0103 extins\u0103 (Long Life) \u00een modul de exploatare de rezerv\u0103 de p\u00e2n\u0103 la 10 ani.<\/p>\n<p>\u0218i seria UPS \u2014 este o baterie special conceput\u0103 pentru utilizarea la curen\u021bi mari cu timp scurt de desc\u0103rcare.<\/p>\n<p>Pentru mine, am ales mult timp \u00eentre UPS \u0219i HRL, dar am decis s\u0103 aleg HRL. Din p\u0103cate, pentru a spune cum se vor comporta \u00een condi\u021bii de func\u021bionare pe termen lung, va trebui s\u0103 a\u0219tept\u0103m aproximativ cinci ani, iar necropostarea nu este apreciat\u0103. A\u0219adar, voi considera aceasta alegerea mea personal\u0103 \u0219i nu \u00eencerc s\u0103 o impun. Dar trebuie s\u0103 \u00een\u021belege\u021bi c\u0103 este necesar s\u0103 alege\u021bi baterii cu curent mare, deoarece acestea trebuie s\u0103 poat\u0103 entrega toat\u0103 capacitatea acumulat\u0103 \u00een decurs de 20-30 de minute. <\/p>\n<h3>Alegerea asambl\u0103rii bateriilor<\/h3>\n<p>\nAv\u00e2nd \u00een vedere c\u0103 \u00een asamblare se utilizeaz\u0103 mai multe acumulatori, este extrem de important ca ace\u0219tia s\u0103 aib\u0103 caracteristici identice. Un acumulator de calitate inferioar\u0103 va duce la o func\u021bionare complet diferit\u0103 a \u00eentregii asambl\u0103ri dec\u00e2t cea a\u0219teptat\u0103.<\/p>\n<p>Acum 5 ani, am descoperit compania din Rostov \u201eBastion\u201d, care produce teste de capacitate pentru acumulatori sub marca comercial\u0103 \u201eScat\u201d. Nu pot afirma c\u0103 m\u0103sur\u0103torile capacit\u0103\u021bii sunt ideale, dar pentru evaluarea nivelului: ideal-vie-\u00eenc\u0103 func\u021bional\u0103-mort, acest tester este mai mult dec\u00e2t suficient. <\/p>\n<p><img decoding=\"async\" alt=\"UPS-uri APC Smart, \u0219i cum s\u0103 le preg\u0103ti\u021bi\" src=\"\/wp-content\/uploads\/2020\/02\/7390b5c6865ebe74998c6d6494c4e548.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nPractic, capacitatea poate fi m\u0103surat\u0103 printr-o simpl\u0103 \u00eenc\u0103rcare-descarcare utiliz\u00e2nd un cronometru, o lamp\u0103 auto de 21W (care ofer\u0103 o sarcin\u0103 de aproximativ 1A) \u0219i un tester, dar aceasta este o metod\u0103 lung\u0103 \u0219i adesea plictisitoare.<\/p>\n<p>Ei bine, \u00een caz extrem \u2013 \u00eencerc\u0103m s\u0103 instal\u0103m acumulatori proaspe\u021bi din aceea\u0219i serie \u0219i sper\u0103m c\u0103 ave\u021bi noroc. <\/p>\n<h3>Electrica este \u0219tiin\u021ba contactelor.<\/h3>\n<p>\nUn contact defect \u00eentr-o asamblare format\u0103 din 4 acumulatori va anula toate eforturile depuse, a\u0219a c\u0103 descompunem asamblarea cu mare aten\u021bie. De obicei, \u00een UPS-uri se folosesc conectori pentru acumulatori cu cleme, care printr-o simpl\u0103 tragere pot fi deteriora\u021bi u\u0219or. A\u0219adar, lu\u0103m o \u0219urubelni\u021b\u0103 mic\u0103, o introducem \u00een conector precum \u00een fotografie \u0219i o scoatem cu grij\u0103, f\u0103r\u0103 a depune eforturi considerabile. A\u0219a cum a sugerat colegul \u00een comentarii \u2013 trebuie s\u0103 tragem de carcas\u0103 din plastic, nu de fir. Conectorul se deta\u0219eaz\u0103 cu un clic u\u0219or.<\/p>\n<p><img decoding=\"async\" alt=\"UPS-uri APC Smart, \u0219i cum s\u0103 le preg\u0103ti\u021bi\" src=\"\/wp-content\/uploads\/2020\/02\/07d704acf5b9c5a92b2ddf6e05f89f2a.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nEi bine, \u00een ceea ce prive\u0219te conectarea corect\u0103 a firelor, cred c\u0103 este de prisos s\u0103 scriu. Dac\u0103 a\u021bi intrat \u00een UPS, atunci cu siguran\u021b\u0103 \u0219ti\u021bi principiul conect\u0103rii \u00een serie a acumulatorilor. Iar pentru ceilal\u021bi: o bucat\u0103 de h\u00e2rtie \u0219i un creion sau un smartphone cu camer\u0103. La finalizarea asambl\u0103rii, pentru siguran\u021b\u0103, m\u0103sur\u0103m voltajul asambl\u0103rii cu un tester \u0219i compar\u0103m cu cel care ar trebui s\u0103 fie, \u00een func\u021bie de num\u0103rul de acumulatori.<\/p>\n<h3>\u201eAm f\u0103cut totul a\u0219a cum era scris, dar nu a ajutat\u201d<\/h3>\n<p>\n\u0218i acum \u00eencepe partea cea mai interesant\u0103. UPS-ul, \u00een timpul func\u021bion\u0103rii sale, efectueaz\u0103 periodic (de obicei o dat\u0103 la 7 sau 14 zile, \u00een func\u021bie de setare) o calibrare scurt\u0103 a bateriei. Acesta comut\u0103 \u00een modul de func\u021bionare de la baterie \u0219i m\u0103soar\u0103 tensiunea imediat \u0219i dup\u0103 o scurt\u0103 perioad\u0103. Rezultatul este un anumit coeficient corectiv \u201evitalitate a bateriei\u201d, pe care \u00eel stocheaz\u0103 \u00een registru. Pe m\u0103sur\u0103 ce bateria se degradeaz\u0103 treptat, starea acestui registru scade treptat. Pe baza acestuia, UPS-ul calculeaz\u0103 timpul r\u0103mas de func\u021bionare de la baterie. \u0218i \u00eentr-un moment dat, realiz\u00e2nd c\u0103 situa\u021bia nu este bun\u0103, UPS-ul aprinde indicatorul care solicit\u0103 \u00eenlocuirea bateriei. Dar, atunci c\u00e2nd facem \u00eenlocuirea, UPS-ul nu \u0219tie despre asta! Starea registrului \u201evitalitate a bateriei\u201d r\u0103m\u00e2ne aceea\u0219i. Trebuie s\u0103 o corect\u0103m.<\/p>\n<p>Exist\u0103 dou\u0103 c\u0103i. Prima cale, simpl\u0103 \u0219i rapid\u0103 \u2013 este necesar\u0103 efectuarea unei calibra\u021bii complete a UPS-ului. Pentru aceasta, trebuie s\u0103-l \u00eencarci cu peste 35% \u0219i s\u0103 lansezi calibrarea, de exemplu, din programul PowerChute. Aceasta func\u021bioneaz\u0103 aproximativ \u00een jum\u0103tate din cazuri. De ce nu \u00eentotdeauna \u2013 este un mister. A\u0219adar, vom opta pentru calea mai lung\u0103, dar mai sigur\u0103.<\/p>\n<p>Ne vor trebui: un computer cu port COM, un cablu original (de exemplu, 940-0024C), programul UpsDiag 2.0 (pentru siguran\u021ba UPS-ului dvs., colegul recomand\u0103 s\u0103 folosi\u021bi mai bine apcfix \u00een modul gratuit. Nu pot s\u0103 spun nimic despre aceasta, \u00een afar\u0103 de faptul c\u0103 nu recomand categoric s\u0103 ap\u0103sa\u021bi altceva \u00een UpsDiag \u00een afar\u0103 de modificarea registrului 0. <i>\u00een special butonul de corectare automat\u0103 a erorii bateriei.<\/i>) \u0219i <noindex><a rel=\"nofollow\" href=\"http:\/\/www.apcupsd.com\/manual\/manual.html#configuring-your-eeprom\">tabelul valorilor de calibrare.<\/a><\/noindex>. Ne intereseaz\u0103 valoarea registrului 0. \u00cen tabel este indicat\u0103 valoarea pentru bateriile ideale, sferice, \u00een vid. Orice baterie real\u0103 va oferi, dup\u0103 calibrare, o valoare mai mic\u0103, dar nu cu mult.<\/p>\n<p><img decoding=\"async\" alt=\"UPS-uri APC Smart, \u0219i cum s\u0103 le preg\u0103ti\u021bi\" src=\"\/wp-content\/uploads\/2020\/02\/93542115e332bece7803efac1c88a284.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nDe exemplu, voi lua un UPS real SUA1500RMI2U. La momentul \u00eenlocuirii bateriei, UpsDiag ar\u0103ta valoarea registrului 0 \u2013 42. Adic\u0103 bateria era moart\u0103. Valoarea de calibrare din tabel este A1. <\/p>\n<p>\u00cencepem s\u0103 corect\u0103m. \u00cen primul r\u00e2nd, <b>decupl\u0103m placa de re\u021bea din UPS.<\/b>. Prezen\u021ba pl\u0103cii de re\u021bea nu v\u0103 va permite s\u0103 corecta\u021bi registrul. De ce \u2013 este o \u00eentrebare pentru inginerii APC. Din fericire, o po\u021bi scoate \u00een timpul func\u021bion\u0103rii, f\u0103r\u0103 a opri UPS-ul. <\/p>\n<p>Conect\u0103m cablul, lans\u0103m UpsDiag, mergem la tab-ul \u201eCalibrare\u201d \u0219i verific\u0103m starea registrului 0. Not\u0103m pe o foaie, facem clic dreapta pe el \u2013 Modificare. \u00cel ridic\u0103m la valoarea din tabelul de valori de calibrare \u2013 A1. Dac\u0103 \u00een tabel nu se afl\u0103 UPS-ul vostru, \u00een principiu, putem s\u0103-l ridic\u0103m la FF. Nu este nimic \u00eengrijor\u0103tor \u00een urma acestui lucru, \u00een afar\u0103 de UPS-ul care va ar\u0103ta c\u0103 este preg\u0103tit s\u0103 suporte sarcina p\u00e2n\u0103 la a doua venire. <\/p>\n<p>Apoi, trebuie s\u0103 a\u0219tept\u0103m \u00eenc\u0103rcarea bateriei de la 0% la 100%, s\u0103 \u00eenc\u0103rc\u0103m UPS-ul la 35% sau pu\u021bin mai mult \u0219i s\u0103 lans\u0103m calibrarea. La finalizarea calibr\u0103rii, din nou ne uit\u0103m la valoarea din registrul 0 \u0219i o compar\u0103m cu cea notat\u0103 pe foaie. \u00cen SUA1500RMI2U men\u021bionat mai sus, cu baterii noi HRL1234W, valoarea a ajuns la \u2013 98, care, \u00een principiu, nu este foarte departe de valoarea de calibrare A1.<\/p>\n<p>Dup\u0103 toate acestea, l\u0103s\u0103m din nou s\u0103 se \u00eencarce p\u00e2n\u0103 la 100%, deconect\u0103m cablul COM, b\u0103g\u0103m \u00eenapoi placa de re\u021bea \u0219i dorim UPS-ului o via\u021b\u0103 lung\u0103 \u0219i fericit\u0103 \u00een folosul serverului nostru.<\/p>\n<p>Apropo, pl\u0103cile de re\u021bea de tip AP9619 pe pia\u021ba secundar\u0103 au sc\u0103zut de asemenea la pre\u021buri indecente. Dar cum s\u0103 le prepari (resetarea parolei, actualizarea firmware-ului, configurarea) \u2013 este un subiect pentru un articol separatat.<br \/>\n<br \/>Sursa: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/487802\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric). \u0412\u0435\u043b\u0438\u043a\u043e\u043b\u0435\u043f\u043d\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0438\u0437\u043a\u0430\u044f \u0446\u0435\u043d\u0430 \u043d\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u043c \u0440\u044b\u043d\u043a\u0435, \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u044e\u0442 \u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u0441\u0438\u0441\u0430\u0434\u043c\u0438\u043d\u044b, \u043e\u0441\u043e\u0431\u043e \u043d\u0435 \u0437\u0430\u0434\u0443\u043c\u044b\u0432\u0430\u044f\u0441\u044c, \u0443\u0442\u044b\u043a\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u043e\u0439\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u043c\u0438 \u0418\u0411\u041f \u0438 \u043f\u044b\u0442\u0430\u044e\u0442\u0441\u044f \u0432\u044b\u0442\u044f\u043d\u0443\u0442\u044c \u0441 \u0436\u0435\u043b\u0435\u0437\u043e\u043a 10-15 \u043b\u0435\u0442\u043d\u0435\u0439 \u0434\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0443\u043c \u043f\u0440\u043e\u0444\u0438\u0442\u0430 \u0431\u0430\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u043e\u0439 \u0430\u043a\u043a\u0443\u043c\u0443\u043b\u044f\u0442\u043e\u0440\u043e\u0432. \u041a \u0441\u043e\u0436\u0430\u043b\u0435\u043d\u0438\u044e \u043d\u0435 \u0432\u0441\u0435\u0433\u0434\u0430 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-56401","post","type-post","status-publish","format-standard","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/ro\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"ro_RO\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/ro\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-02-11T21:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-02-18T11:04:41+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47UPS-uri APC Smart UPS \u0219i cum s\u0103 le preg\u0103tim | ProHoster","description":"Printre diversitatea de UPS-uri, cele mai r\u0103sp\u00e2ndite \u00een serverele de nivel de \u00eenceput sunt Smart UPS de la APC (acum \u2013 Schneider Electric).","canonical_url":"https:\/\/prohoster.info\/ro\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"ro_RO","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster","og:description":"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).","og:url":"https:\/\/prohoster.info\/ro\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-02-11T21:00:00+00:00","article:modified_time":"2020-02-18T11:04:41+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"56401","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 19:25:39","updated":"2022-09-29 13:07:34","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/ro\/wp-json\/wp\/v2\/posts\/56401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/ro\/wp-json\/wp\/v2\/comments?post=56401"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/ro\/wp-json\/wp\/v2\/posts\/56401\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/ro\/wp-json\/wp\/v2\/media?parent=56401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/ro\/wp-json\/wp\/v2\/categories?post=56401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/ro\/wp-json\/wp\/v2\/tags?post=56401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}