{"id":56401,"date":"2020-02-12T00:00:00","date_gmt":"2020-02-11T21:00:00","guid":{"rendered":"https:\/\/prohoster.info\/blog\/blog_prohoster\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit"},"modified":"2020-02-18T14:04:41","modified_gmt":"2020-02-18T11:04:41","slug":"besperebojniki-apc-smart-ups-i-kak-ih-gotovit","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sk\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","title":{"rendered":"Nepretr\u017eit\u00e9 nap\u00e1jacie zdroje APC Smart UPS a ako ich pripravi\u0165","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Medzi v\u0161etk\u00fdmi typmi UPS s\u00fa najroz\u0161\u00edrenej\u0161ie v serveroch ni\u017e\u0161ej \u00farovne Smart UPS od firmy APC (teraz \u2013 Schneider Electric). Vynikaj\u00faca spo\u013eahlivos\u0165 a n\u00edzka cena na sekund\u00e1rnom trhu ved\u00fa k tomu, \u017ee administr\u00e1tori, bez v\u00e4\u010d\u0161\u00edch \u00favah, zap\u013a\u0148aj\u00fa skrine t\u00fdmito UPS a sna\u017eia sa vy\u0165a\u017ei\u0165 z hardv\u00e9ru star\u00e9ho 10-15 rokov maxim\u00e1lny zisk jednoduchou v\u00fdmenou bat\u00e9ri\u00ed. \u017dia\u013e, nie v\u017edy to prin\u00e1\u0161a o\u010dak\u00e1van\u00fd v\u00fdsledok. Pok\u00fasime sa zisti\u0165, \u010do a ako treba robi\u0165, aby v\u00e1\u0161 UPS fungoval \u201eako nov\u00fd\u201c.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<h3>V\u00fdber bat\u00e9ri\u00ed<\/h3>\n<p>\nV\u0161etky \u010dl\u00e1nky a t\u00e9my na f\u00f3rach o v\u00fdbere bat\u00e9ri\u00ed pre UPS \u010dastej\u0161ie pripom\u00ednaj\u00fa t\u00e9my o v\u00fdbere motorov\u00e9ho oleja pre aut\u00e1\/motorky. Pok\u00fasime sa neupodobni\u0165 im, ale porozumie\u0165 z\u00e1kladn\u00fdm z\u00e1sad\u00e1m v\u00fdberu bat\u00e9ri\u00ed na pr\u00edklade v\u00fdrobcu CSB. <\/p>\n<p>Vid\u00edme u nich mno\u017estvo r\u00f4znych l\u00edni\u00ed bat\u00e9ri\u00ed: GP, GPL, HR, HRL, UPS, TPL. <\/p>\n<p>Za\u010d\u00edn\u00e1me \u010d\u00edta\u0165: GP, GPL \u2014 bat\u00e9rie univerz\u00e1lneho pou\u017eitia <b>pre mal\u00e9 a stredn\u00e9 pr\u00fady vyb\u00edjania<\/b>. Odpor\u00fa\u010daj\u00fa sa na pou\u017eitie v bezpe\u010dnostn\u00fdch a protipo\u017eiarnych syst\u00e9moch a UPS. N\u00e1m sa nehodia. Aj ke\u010f ich pr\u00e1ve naj\u010dastej\u0161ie kupuj\u00fa, ani sa neun\u00favaj\u00fa presk\u00fama\u0165 ich vlastnosti. <\/p>\n<p><img decoding=\"async\" alt=\"Nepretr\u017eit\u00e9 nap\u00e1jacie zdroje APC Smart UPS a ako ich pripravi\u0165\" src=\"\/wp-content\/uploads\/2020\/02\/8daafaf7943d755075773d981e84d94c.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nS\u00e9ria HR \u2014 bat\u00e9rie s vy\u0161\u0161ou energetickou kapacitou a umo\u017e\u0148uj\u00face hlbok\u00e9 vyb\u00edjanie (a\u017e do 11% zvy\u0161kov\u00e9ho nabitia), s\u00fa obzvl\u00e1\u0161\u0165 u\u017eito\u010dn\u00e9 pri potrebe vysok\u00fdch pr\u00fadov vyb\u00edjania. Rozl\u00ed\u0161enie bat\u00e9ri\u00ed \u201eH\u201c je \u0161peci\u00e1lna kon\u0161trukcia mrie\u017eky, ktor\u00e1 zvy\u0161uje v\u00fdstupn\u00fd v\u00fdkon o 20%. Tieto bat\u00e9rie s\u00fa najlep\u0161ie vhodn\u00e9 na pou\u017eitie vo v\u00fdkonn\u00fdch energetick\u00fdch zariadeniach a UPS.<\/p>\n<p>P\u00edsmeno \u201eL\u201c v s\u00e9rii indikuje, \u017ee ide o bat\u00e9rie so zv\u00fd\u0161enou \u017eivotnos\u0165ou (Long Life) pri prev\u00e1dzke a\u017e do 10 rokov v bat\u00e9riovom re\u017eime.<\/p>\n<p>A s\u00e9ria UPS \u2014 to s\u00fa \u0161peci\u00e1lne navrhnut\u00e9 bat\u00e9rie na prev\u00e1dzku pri vysok\u00fdch pr\u00fadoch s kr\u00e1tkym \u010dasom vyb\u00edjania.<\/p>\n<p>Dlho som si vyberal medzi UPS a HRL, ale rozhodol som sa pre HRL. \u017dia\u013e, poveda\u0165, ako sa bud\u00fa spr\u00e1va\u0165 pri dlhodobej pr\u00e1ci, m\u00f4\u017eem a\u017e o 5 rokov, a postova\u0165 na f\u00f3rach o tom sa zd\u00e1 by\u0165 nevhodn\u00e9. Preto budeme pova\u017eova\u0165, \u017ee toto je m\u00f4j osobn\u00fd v\u00fdber a n\u00fati\u0165 v\u00e1s k nemu nepl\u00e1nujem. Ale mus\u00edte ch\u00e1pa\u0165, \u017ee je potrebn\u00e9 vybra\u0165 vysokopr\u00fadov\u00e9 bat\u00e9rie, preto\u017ee musia by\u0165 schopn\u00e9 odovzda\u0165 v\u0161etku akumulovan\u00fa kapacitu po\u010das 20-30 min\u00fat. <\/p>\n<h3>V\u00fdber zostavy bat\u00e9ri\u00ed<\/h3>\n<p>\nKe\u010f\u017ee sa v zostave pou\u017e\u00edva nieko\u013eko bat\u00e9ri\u00ed, je ve\u013emi \u017eelate\u013en\u00e9, aby mali rovnak\u00e9 parametre. Preto\u017ee jedna nekvalitn\u00e1 bat\u00e9ria sp\u00f4sob\u00ed, \u017ee cel\u00e1 zostava nebude fungova\u0165 tak, ako sa o\u010dak\u00e1va.<\/p>\n<p>Pred asi 5 rokmi som objavil ro\u0161kov\u00fa spolo\u010dnos\u0165 \u201eBastion\u201c, ktor\u00e1 vyr\u00e1ba testery kapacity bat\u00e9ri\u00ed pod obchodnou zna\u010dkou \u201eSkat\u201c. Nem\u00f4\u017eem tvrdi\u0165, \u017ee merania kapacity s\u00fa \u00faplne presn\u00e9, ale na hodnotenie \u00farovne: ide\u00e1lne \u2013 \u017eiv\u00e9 \u2013 e\u0161te posl\u00fa\u017ei \u2013 m\u0155tve, tento tester je viac ne\u017e dos\u0165. <\/p>\n<p><img decoding=\"async\" alt=\"Nepretr\u017eit\u00e9 nap\u00e1jacie zdroje APC Smart UPS a ako ich pripravi\u0165\" src=\"\/wp-content\/uploads\/2020\/02\/7390b5c6865ebe74998c6d6494c4e548.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nV podstate je mo\u017en\u00e9 mera\u0165 kapacitu jednoduch\u00fdm nab\u00edjan\u00edm a vyb\u00edjan\u00edm s pou\u017eit\u00edm hod\u00edn, automobilovej \u017eiarovky na 21 W (poskytuje z\u00e1\u0165a\u017e okolo 1 A) a testeru, ale je to zd\u013ahav\u00e9 a v\u00e4\u010d\u0161inou lenivos\u0165.<\/p>\n<p>V najhor\u0161om pr\u00edpade sa sna\u017e\u00edme pou\u017e\u00edva\u0165 nov\u00e9 bat\u00e9rie z jednej s\u00e9rie a d\u00fafa\u0165, \u017ee budeme ma\u0165 \u0161\u0165astie. <\/p>\n<h3>Elektrina je veda o kontaktoch.<\/h3>\n<p>\nJedno zl\u00e9 spojenie v zostave zo 4 bat\u00e9ri\u00ed vyru\u0161\u00ed v\u0161etky va\u0161e snahy, preto treba zostavu rozobera\u0165 ve\u013emi opatrne. Zvy\u010dajne sa v UPS pou\u017e\u00edvaj\u00fa konektory pre bat\u00e9rie so z\u00e1mkami, ktor\u00e9 jednoduch\u00fdm vytiahnut\u00edm m\u00f4\u017eu by\u0165 rovnako jednoducho zni\u010den\u00e9. Preto zoberme mal\u00fd ploch\u00fd skrutkova\u010d, vlo\u017eme ho do konektora ako na fotke a opatrne ho odstr\u00e1nime, bez zvl\u00e1\u0161tnych n\u00e1mahy. Ako nazna\u010dil kolega v koment\u00e1ri - treba proste \u0165aha\u0165 za plastov\u00fd kryt, a nie za k\u00e1bel. Konektor sa odober\u00e1 s \u013eahk\u00fdm cvaknut\u00edm.<\/p>\n<p><img decoding=\"async\" alt=\"Nepretr\u017eit\u00e9 nap\u00e1jacie zdroje APC Smart UPS a ako ich pripravi\u0165\" src=\"\/wp-content\/uploads\/2020\/02\/07d704acf5b9c5a92b2ddf6e05f89f2a.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nPokia\u013e ide o spr\u00e1vne spojenie k\u00e1blov, mysl\u00edm, \u017ee je zbyto\u010dn\u00e9 o tom p\u00edsa\u0165. Ak ste sa dostali dnu do UPS, ur\u010dite pozn\u00e1te princ\u00edp s\u00e9riov\u00e9ho zapojenia bat\u00e9ri\u00ed. A pre ostatn\u00fdch: papierik a pero alebo smartf\u00f3n s kamerou. Po skon\u010den\u00ed zostavy, pre istotu, zmerajte testerom nap\u00e4tie v zostave a porovnajte ho s t\u00fdm, ktor\u00e9 by malo by\u0165, na z\u00e1klade po\u010dtu bat\u00e9ri\u00ed.<\/p>\n<h3>\u201eUrobil som v\u0161etko, ako je nap\u00edsan\u00e9, ale nepomohlo to\u201c<\/h3>\n<p>\nAle teraz za\u010d\u00edna to najzauj\u00edmavej\u0161ie. UPS po\u010das svojej pr\u00e1ce periodicky (obe\u017ene raz za 7 alebo 14 dn\u00ed, v z\u00e1vislosti od nastavenia) vykon\u00e1va kr\u00e1tku kalibr\u00e1ciu bat\u00e9rie. Prepne sa do re\u017eimu prev\u00e1dzky z bat\u00e9rie a zmeria nap\u00e4tie okam\u017eite a po malom \u010dase. V\u00fdsledkom toho je ist\u00fd korek\u010dn\u00fd koeficient \u201e\u017eivotnosti bat\u00e9rie\u201c, ktor\u00fd si ulo\u017e\u00ed do registra. V procese postupn\u00e9ho umierania bat\u00e9rie sa stav tohto registra postupne zni\u017euje. Na jeho z\u00e1klade UPS po\u010d\u00edta zost\u00e1vaj\u00faci \u010das prev\u00e1dzky z bat\u00e9rie. A v jednom kr\u00e1snom momente, ke\u010f pochop\u00ed, \u017ee je to zl\u00e9, UPS rozsvieti indik\u00e1tor po\u017eiadavky na v\u00fdmenu bat\u00e9rie. Ale ke\u010f rob\u00edme v\u00fdmenu, UPS o tom nevie! Stav registra \u201e\u017eivotnosti bat\u00e9rie\u201c ost\u00e1va rovnak\u00fd. Mus\u00edme ho opravi\u0165.<\/p>\n<p>Existuj\u00fa dve cesty. Prv\u00e1, jednoduch\u00e1 a r\u00fdchla \u2013 je potrebn\u00e9 vykona\u0165 \u00fapln\u00fa kalibr\u00e1ciu UPS. Na to je potrebn\u00e9 za\u0165a\u017ei\u0165 ho viac ako 35 % a spusti\u0165 kalibr\u00e1ciu, napr\u00edklad z programu PowerChute. To zafunguje pribli\u017ene v polovici pr\u00edpadov. Pre\u010do nie v\u017edy \u2013 to je z\u00e1hada zahalen\u00e1 tajomstvom. Preto p\u00f4jdeme dlh\u0161ou, ale spo\u013eahlivej\u0161ou cestou.<\/p>\n<p>Budeme potrebova\u0165: po\u010d\u00edta\u010d s COM portom, origin\u00e1lny k\u00e1bel (napr\u00edklad 940-0024C), program UpsDiag 2.0 (pre bezpe\u010dnos\u0165 v\u00e1\u0161ho UPS kolega odpor\u00fa\u010da rad\u0161ej pou\u017ei\u0165 apcfix v bezplatnom re\u017eime). Ni\u010d nem\u00f4\u017eem poveda\u0165 k tomu okrem toho, \u017ee kategoricky neodpor\u00fa\u010dam v UpsDiag klikn\u00fa\u0165 na nie\u010do okrem \u00fapravy 0 registra, <i>najm\u00e4 na tla\u010didlo automatickej opravy chyby bat\u00e9rie<\/i>) a <noindex><a rel=\"nofollow\" href=\"http:\/\/www.apcupsd.com\/manual\/manual.html#configuring-your-eeprom\">tabu\u013eka kalibra\u010dn\u00fdch hodn\u00f4t<\/a><\/noindex>. Zauj\u00edma n\u00e1s hodnota registra 0. V tabu\u013eke je uveden\u00e1 hodnota pre ide\u00e1lne, gu\u013eov\u00e9 bat\u00e9rie vo v\u00e1kuu. Ak\u00e9ko\u013evek re\u00e1lne bat\u00e9rie daj\u00fa po kalibr\u00e1cii hodnotu ni\u017e\u0161iu, ale nie ve\u013emi.<\/p>\n<p><img decoding=\"async\" alt=\"Nepretr\u017eit\u00e9 nap\u00e1jacie zdroje APC Smart UPS a ako ich pripravi\u0165\" src=\"\/wp-content\/uploads\/2020\/02\/93542115e332bece7803efac1c88a284.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nNa pr\u00edklade vezmem re\u00e1lny UPS SUA1500RMI2U. V \u010dase v\u00fdmeny bat\u00e9rie, UpsDiag ukazoval hodnotu registra 0 \u2013 42. To znamen\u00e1, \u017ee bat\u00e9rie s\u00fa m\u0155tve. Kalibra\u010dn\u00e1 hodnota z tabu\u013eky \u2013 A1. <\/p>\n<p>Za\u010d\u00edname s opravou. Prv\u00fdm krokom <b>odpoj\u00edme sie\u0165ov\u00fa kartu z UPS<\/b>. Pr\u00edtomnos\u0165 sie\u0165ovej karty v\u00e1m neumo\u017en\u00ed opravi\u0165 register. Pre\u010do \u2013 ot\u00e1zka pre in\u017einierov APC. Na\u0161\u0165astie ju m\u00f4\u017eete vytiahnu\u0165 za behu, bez vypnutia UPS. <\/p>\n<p>Pripojte k\u00e1bel, spustite UpsDiag, cho\u010fte na kartu \u201eKalibr\u00e1cia\u201c a sledujte stav registru 0. Zap\u00ed\u0161te si ho, kliknite na\u0148 prav\u00fdm tla\u010didlom my\u0161i \u2013 Zmeni\u0165. Zv\u00fd\u0161te jeho hodnotu na \u00farove\u0148 uveden\u00fa v kalibra\u010dnej tabu\u013eke \u2013 A1. Ak v\u00e1\u0161 UPS nie je v tabu\u013eke, v podstate ho m\u00f4\u017eete nastavi\u0165 na FF. Ni\u010d zl\u00e9 sa od toho nestane, okrem prekvapen\u00e9ho UPS, ktor\u00fd uk\u00e1\u017ee, \u017ee je pripraven\u00fd zvl\u00e1da\u0165 z\u00e1\u0165a\u017e a\u017e do druh\u00e9ho pr\u00edchodu. <\/p>\n<p>Potom mus\u00edme po\u010dka\u0165, k\u00fdm sa akumul\u00e1tor nabi\u0165 na 100 %, za\u0165a\u017ei\u0165 UPS na 35 % alebo trochu viac a spusti\u0165 kalibr\u00e1ciu. Po skon\u010den\u00ed kalibr\u00e1cie sa op\u00e4\u0165 pozrieme na hodnotu v registri 0 a porovn\u00e1me ju so zap\u00edsanou hodnotou. V vy\u0161\u0161ie op\u00edsanom SUA1500RMI2U s nov\u00fdmi akumul\u00e1tormi HRL1234W sa hodnota stala \u2013 98, \u010do nie je ve\u013emi \u010faleko od kalibra\u010dn\u00e9ho A1.<\/p>\n<p>Po v\u0161etkom nech\u00e1me znova nab\u00edja\u0165 na 100 %, odpojte COM k\u00e1bel, znovu zapnite sie\u0165ov\u00fa kartu a prajeme UPS dlh\u00fd a \u0161\u0165astn\u00fd \u017eivot pre dobro na\u0161ej serverovej skrine.<\/p>\n<p>Mimochodom, sie\u0165ov\u00e9 karty, ako AP9619, na sekund\u00e1rnom trhu tie\u017e klesli na nepr\u00edjemne n\u00edzke ceny. Ale ako ich pripravi\u0165 (resetovanie hesla, aktualiz\u00e1cia firmv\u00e9ru, nastavenie) \u2013 to je t\u00e9ma na samostatn\u00fd \u010dl\u00e1nok.<br \/>\n<br \/>Zdroj: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/487802\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric). \u0412\u0435\u043b\u0438\u043a\u043e\u043b\u0435\u043f\u043d\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0438\u0437\u043a\u0430\u044f \u0446\u0435\u043d\u0430 \u043d\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u043c \u0440\u044b\u043d\u043a\u0435, \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u044e\u0442 \u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u0441\u0438\u0441\u0430\u0434\u043c\u0438\u043d\u044b, \u043e\u0441\u043e\u0431\u043e \u043d\u0435 \u0437\u0430\u0434\u0443\u043c\u044b\u0432\u0430\u044f\u0441\u044c, \u0443\u0442\u044b\u043a\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u043e\u0439\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u043c\u0438 \u0418\u0411\u041f \u0438 \u043f\u044b\u0442\u0430\u044e\u0442\u0441\u044f \u0432\u044b\u0442\u044f\u043d\u0443\u0442\u044c \u0441 \u0436\u0435\u043b\u0435\u0437\u043e\u043a 10-15 \u043b\u0435\u0442\u043d\u0435\u0439 \u0434\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0443\u043c \u043f\u0440\u043e\u0444\u0438\u0442\u0430 \u0431\u0430\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u043e\u0439 \u0430\u043a\u043a\u0443\u043c\u0443\u043b\u044f\u0442\u043e\u0440\u043e\u0432. \u041a \u0441\u043e\u0436\u0430\u043b\u0435\u043d\u0438\u044e \u043d\u0435 \u0432\u0441\u0435\u0433\u0434\u0430 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-56401","post","type-post","status-publish","format-standard","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sk\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"sk_SK\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sk\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-02-11T21:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-02-18T11:04:41+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Z\u00e1lo\u017en\u00e9 zdroje APC Smart UPS a ako ich pripravi\u0165 | ProHoster","description":"Medzi v\u0161etk\u00fdmi r\u00f4znymi UPS s\u00fa najbe\u017enej\u0161ie v serveroch na za\u010diatku \u00farovne Smart UPS od firmy APC (teraz \u2013 Schneider Electric).","canonical_url":"https:\/\/prohoster.info\/sk\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sk_SK","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster","og:description":"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).","og:url":"https:\/\/prohoster.info\/sk\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-02-11T21:00:00+00:00","article:modified_time":"2020-02-18T11:04:41+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"56401","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 19:25:39","updated":"2022-09-29 13:07:34","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sk\/wp-json\/wp\/v2\/posts\/56401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sk\/wp-json\/wp\/v2\/comments?post=56401"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/sk\/wp-json\/wp\/v2\/posts\/56401\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sk\/wp-json\/wp\/v2\/media?parent=56401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sk\/wp-json\/wp\/v2\/categories?post=56401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sk\/wp-json\/wp\/v2\/tags?post=56401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}