{"id":30008,"date":"2019-10-31T21:33:10","date_gmt":"2019-10-31T18:33:10","guid":{"rendered":"https:\/\/prohoster.info\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat\/"},"modified":"2019-10-31T21:33:10","modified_gmt":"2019-10-31T18:33:10","slug":"vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sl\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat","title":{"rendered":"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/7832ecf74ccec07328f8e99b01ccb81f.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/dataline\/blog\/432980\/\">\u010cas\u0165 prv\u00e1<\/a><\/noindex><br \/>\nPo kraj\u0161em odmoru se vra\u010damo k NSX. Danes bom pokazal, kako nastaviti NAT in po\u017earni zid.<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nV zavihku <b>Administracija<\/b> pojdi v svoj virtualni podatkovni center \u2013 <b>Obla\u010dni viri \u2013 Virtualni podatkovni centri<\/b>. <\/p>\n<p>Izberite zavihek <b>Edge Gateways<\/b> in na potrebni NSX Edge kliknite z desno mi\u0161kino tipko. V prikazanem meniju izberite mo\u017enost <b>Edge Gateway Services<\/b>. Nadzorna plo\u0161\u010da NSX Edge se bo odprla v novem zavihku.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/53dd4a66d2ad186361068541c5c9ccbd.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h3>Nastavitev pravil po\u017earnega zida<\/h3>\n<p>\nPrivzeto je v rubriki <b>default rule for ingress traffic<\/b> izbrana mo\u017enost Dovoli, to pomeni, da bo po\u017earni zid blokiral ves promet.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/7afeb9fd3395deb50eb821c449e8097d.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n <br \/>\nDa dodate novo pravilo, pritisnite +. Pojavila se bo nova vrstica z naslovom <b>Novo pravilo<\/b>. Uredite njena polja v skladu z va\u0161imi zahtevami.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/81ff3b24755037f2ff59929302dab506.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nV polju <b>Ime<\/b> dolo\u010dite naslov pravila, na primer Internet.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/20ca48498e5828adc55f9e320b174c86.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nV polju <b>Vir<\/b> vnesite potrebne naslove vira. S funkcijo IP lahko dolo\u010dite posamezen IP naslov, razpon IP naslovov ali CIDR.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/ff41fd0ba2fd3efb9cce4de006daacc8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/fbf8c474a153b1c2ab04bb0a768bddf4.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n <br \/>\nS funkcijo + lahko dolo\u010dite druge objekte:<\/p>\n<ul>\n<li>Vrata usmerjevalnika. Vse notranje mre\u017ee (Internal), vse zunanje mre\u017ee (External) ali Kdorkoli.\n<\/li>\n<li>Virtualne naprave. Priklju\u010dimo pravila na dolo\u010deno virtualno napravo.\n<\/li>\n<li>OrgVdcNetworks. Mre\u017ee na ravni organizacije.\n<\/li>\n<li>Nabori IP. Vnaprej ustvarjena uporabni\u0161ka skupina IP naslovov (ustvari se v objektu grupiranja).\n<\/li>\n<\/ul>\n<p>\n<img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/a1857b7397da44595c9ad5a9333b7656.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/30150e004add4a2d8c3acf08aff69b24.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nV polju <b>Destination<\/b> dolo\u010dite naslov prejemnika. Tu so enake mo\u017enosti kot na polju Vir.<br \/>\nV polju <b>Storitev<\/b> lahko izberete ali ro\u010dno dolo\u010dite vrata prejemnika (Destination Port), potreben protokol (Protocol), vrata po\u0161iljatelja (Source Port). Pritisnite Shrani.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/32bec78ca59ec8abbc944f0544e52365.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/e007ccf49b922f14445919c5ff949451.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nV polju <b>Action<\/b> izberite potrebno dejanje: dovolite pretok prometa, ki ustreza temu pravilu, ali prepovejte.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/ed6453a0e250a4cf817b67855d3094c0.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nUporabimo vneseno konfiguracijo, tako da izberemo to\u010dko <b>Shrani spremembe<\/b>.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/942a0a31c1329237af9bc16f76eab6fb.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<b>Primeri pravil<\/b><\/p>\n<p><i>Pravilo 1 za po\u017earni zid (Internet)<\/i> dovoli dostop do interneta po vseh protokolih stre\u017eniku z IP 192.168.1.10. <\/p>\n<p><i>Pravilo 2 za po\u017earni zid (Spletni stre\u017enik)<\/i> dovoli dostop iz interneta po (TCP protokol, vrata 80) preko va\u0161e zunanje naslovne oznake. V tem primeru \u2013 185.148.83.16:80.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/c0ed5a3d5b4f0972fc4326e4cd3a102b.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h1>Nastavitev NAT<\/h1>\n<p>\n<b>NAT (prevedba omre\u017enih naslovov)<\/b> je proces, ki pretvarja zasebne (sive) IP naslove v zunanje (bele) in obratno. S tem procesom virtualna naprava pridobi dostop do interneta. Za nastavitev tega mehanizma je potrebno nastaviti pravila SNAT in DNAT.<br \/>\nPomembno! NAT deluje samo, \u010de je po\u017earni zid vklopljen in so nastavljena ustrezna dovoljenja.<\/p>\n<p><b>Ustvarjanje pravila SNAT.<\/b> SNAT (prevedba omre\u017enih naslovov izvora) je mehanizem, katerega bistvo je, da zamenja izvorni naslov med po\u0161iljanjem paketa. <\/p>\n<p>Najprej je treba vedeti, kateri zunanji IP naslov ali razpon IP naslovov je na voljo. Zato pojdite na razdelek <b>Administracija<\/b> dvojito kliknite na virtualni podatkovni center. V odpretem meniju nastavitev pojdite na zavihek <b>Edge Gateway<\/b>in izberite \u017eeljeni NSX Edge, nato nanj kliknite z desno mi\u0161kino tipko. Izberite mo\u017enost <b>Properties<\/b>.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/fe916f4d7a78f559e4ba7982e1be6855.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nV odpretem oknu na zavihku <b>Sub-Allocate IP Pools<\/b> lahko si ogledate zunanji IP-naslov ali obseg IP-naslovov. Zapi\u0161ite ga ali si ga zapomnite.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/e52dbc90f57d0b273a9e547c9ac1f854.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nNato kliknite na NSX Edge z desno mi\u0161kino tipko. V odpretem meniju izberite mo\u017enost <b>Edge Gateway Services<\/b>. Tako smo spet v <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/sl\/control-panel\/\"   title=\"administracijski plo\u0161\u010di\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"537\">administracijski plo\u0161\u010di<\/a> NSX Edge.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/50fc0194a0a3ca03e2238f8a31017921.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nV odpretem oknu odprite zavihek NAT in kliknite na Add SNAT. <\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/371287db97e6a6dac1f688d2b78af20a.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nV novem oknu vnesite: <\/p>\n<ul>\n<li>v polje Applied on \u2013 zunanjo omre\u017eje (ne omre\u017eje na ravni organizacije!); <\/li>\n<li>Original Source IP\/range \u2013 notranji obseg naslovov, na primer, 192.168.1.0\/24;<\/li>\n<li>Translated Source IP\/range \u2013 zunanji naslov, preko katerega bo omogo\u010den dostop do interneta in ki ste ga videli na zavihku Sub-Allocate IP Pools.<\/li>\n<\/ul>\n<p>\nPritisnite Obdr\u017ei. <\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/aed08ee1621feeed3979889e9d962237.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\n<b>Ustvarjanje pravila DNAT.<\/b> DNAT je mehanizem, ki spreminja naslov cilja paketa in tudi vrata cilja. Uporablja se za preusmeritev prihajajo\u010dih paketov z zunanjega naslova\/vrata na privatni IP-naslov\/vrata znotraj zasebnega omre\u017eja. <\/p>\n<p>Izberite zavihek NAT in kliknite na Add DNAT.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/fb66ecd7a49b0d280ded36ba0e214c8d.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nV odpretem oknu vnesite:<\/p>\n<p> \u2014 v polje Applied on \u2013 zunanjo omre\u017eje (ne omre\u017eje na ravni organizacije!);<br \/>\n \u2014 Original IP\/range \u2013 zunanji naslov (naslov iz zavihka Sub-Allocate IP Pools);<br \/>\n \u2014 Protocol \u2013 protokol; <br \/>\n \u2014 Original Port \u2013 vrata za zunanji naslov; <br \/>\n \u2014 Translated IP\/range \u2013 notranji IP-naslov, na primer, 192.168.1.10<br \/>\n \u2014 Translated Port \u2013 vrata za notranji naslov, na katerega bo preusmerjeno vrata zunanjega naslova. <\/p>\n<p>Pritisnite Obdr\u017ei.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/da428038cf8f6821dc092adaa33d891a.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nUporabimo vneseno konfiguracijo, tako da izberemo to\u010dko <b>Shrani spremembe<\/b>.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/e88de8bd19d4caa2a03a84b8294fa57e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nPripravljeno.<\/p>\n<p><img decoding=\"async\" alt=\"VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT\" src=\"\/wp-content\/uploads\/2019\/03\/050d5c167d66c5d3e5ee83378bf486f4.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nNato sledi navodilo o DHCP, vklju\u010dno z nastavitvijo DHCP Bindings in Relay.<br \/>\n<br \/>Izvor: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/dataline\/blog\/441026\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0427\u0430\u0441\u0442\u044c \u043f\u0435\u0440\u0432\u0430\u044f \u041f\u043e\u0441\u043b\u0435 \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u0430 \u0432\u043e\u0437\u0432\u0440\u0430\u0449\u0430\u0435\u043c\u0441\u044f \u043a NSX. \u0421\u0435\u0433\u043e\u0434\u043d\u044f \u043f\u043e\u043a\u0430\u0436\u0443, \u043a\u0430\u043a \u043d\u0430\u0441\u0442\u0440\u043e\u0438\u0442\u044c NAT \u0438 Firewall. \u0412\u043e \u0432\u043a\u043b\u0430\u0434\u043a\u0435 Administration \u043f\u0435\u0440\u0435\u0439\u0434\u0438\u0442\u0435 \u0432 \u0432\u0430\u0448 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u0434\u0430\u0442\u0430-\u0446\u0435\u043d\u0442\u0440 \u2013 Cloud Resources \u2013 Virtual Datacenters. \u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u0432\u043a\u043b\u0430\u0434\u043a\u0443 Edge Gateways \u0438 \u043a\u043b\u0438\u043a\u043d\u0438\u0442\u0435 \u043d\u0430 \u043d\u0443\u0436\u043d\u044b\u0439 NSX Edge \u043f\u0440\u0430\u0432\u043e\u0439 \u043a\u043d\u043e\u043f\u043a\u043e\u0439 \u043c\u044b\u0448\u0438. \u0412 \u043f\u043e\u044f\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u043c\u0435\u043d\u044e \u0432\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043e\u043f\u0446\u0438\u044e Edge Gateway Services. \u041f\u0430\u043d\u0435\u043b\u044c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f NSX Edge \u043e\u0442\u043a\u0440\u043e\u0435\u0442\u0441\u044f [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[10],"tags":[],"class_list":["post-30008","post","type-post","status-publish","format-standard","hentry","category-blog"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sl\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"sl_SI\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47VMware NSX \u0434\u043b\u044f \u0441\u0430\u043c\u044b\u0445 \u043c\u0430\u043b\u0435\u043d\u044c\u043a\u0438\u0445. \u0427\u0430\u0441\u0442\u044c 2. \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 Firewall \u0438 NAT | ProHoster\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sl\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T18:33:10+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T18:33:10+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47VMware NSX za najmanj\u0161e. Del 2. Nastavitev po\u017earnega zidu in NAT | ProHoster","description":"","canonical_url":"https:\/\/prohoster.info\/sl\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sl_SI","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47VMware NSX \u0434\u043b\u044f \u0441\u0430\u043c\u044b\u0445 \u043c\u0430\u043b\u0435\u043d\u044c\u043a\u0438\u0445. \u0427\u0430\u0441\u0442\u044c 2. \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 Firewall \u0438 NAT | ProHoster","og:url":"https:\/\/prohoster.info\/sl\/blog\/vmware-nsx-dlya-samyh-malenkih-chast-2-nastrojka-firewall-i-nat","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T18:33:10+00:00","article:modified_time":"2019-10-31T18:33:10+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"30008","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"Article","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-02-08 19:52:40","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 03:44:39","updated":"2026-02-08 19:52:40","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/posts\/30008","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/comments?post=30008"}],"version-history":[{"count":1,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/posts\/30008\/revisions"}],"predecessor-version":[{"id":157727,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/posts\/30008\/revisions\/157727"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/media?parent=30008"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/categories?post=30008"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/tags?post=30008"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}