{"id":87313,"date":"2020-07-07T01:42:43","date_gmt":"2020-07-06T23:42:43","guid":{"rendered":"https:\/\/prohoster.info\/blog\/administrirovanie\/sobiraem-server-dlya-graficheskih-i-cad-cam-prilozhenij-dlya-udalennoj-raboty-po-rdp-na-baze-bu-cisco-ucs-c220-m3-v2"},"modified":"2020-07-07T01:42:43","modified_gmt":"2020-07-06T23:42:43","slug":"sobiraem-server-dlya-graficheskih-i-cad-cam-prilozhenij-dlya-udalennoj-raboty-po-rdp-na-baze-bu-cisco-ucs-c220-m3-v2","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sl\/blog\/administrirovanie\/sobiraem-server-dlya-graficheskih-i-cad-cam-prilozhenij-dlya-udalennoj-raboty-po-rdp-na-baze-bu-cisco-ucs-c220-m3-v2","title":{"rendered":"\u0421\u043e\u0431\u0438\u0440\u0430\u0435\u043c \u0441\u0435\u0440\u0432\u0435\u0440 \u0434\u043b\u044f \u0433\u0440\u0430\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 CAD\/CAM \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u043f\u043e RDP \u043d\u0430 \u0431\u0430\u0437\u0435 \u0431\u0443 CISCO UCS-C220 M3 v2","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"\u0421\u043e\u0431\u0438\u0440\u0430\u0435\u043c \u0441\u0435\u0440\u0432\u0435\u0440 \u0434\u043b\u044f \u0433\u0440\u0430\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 CAD\/CAM \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u043f\u043e RDP \u043d\u0430 \u0431\u0430\u0437\u0435 \u0431\u0443 CISCO UCS-C220 M3 v2\" src=\"\/wp-content\/uploads\/2020\/07\/6abcb22f85603d13d7e53600db9972a1.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nSkoraj vsaka podjetja danes nujno ima oddelek ali skupino, ki dela v CAD\/CAM <br \/>\nali te\u017ekih oblikovalskih programih. To skupino uporabnikov povezujejo resne zahteve glede strojne opreme: veliko pomnilnika \u2014 64 GB in ve\u010d, profesionalna grafi\u010dna kartica, hiter SSD in da je zanesljivo. Pogosto podjetja kupijo nekaterim uporabnikom iz teh oddelkov ve\u010d mo\u010dnih osebnih ra\u010dunalnikov (ali grafi\u010dnih delovnih postaj) in ostalim manj mo\u010dne, odvisno od potreb in tudi finan\u010dnih zmo\u017enosti podjetja. To je pogosto standardni pristop za re\u0161evanje takih nalog in deluje normalno. Vendar je bil med pandemijo in pri oddaljenem delu, pa tudi na splo\u0161no \u2014 tak pristop neoptimalen, zelo previsok in izjemno neprijeten za administracijo, upravljanje in druge vidike. Zakaj je tako in katera re\u0161itev bi idealno zadovoljila potrebe po grafi\u010dnih delovnih postajah v \u0161tevilnih podjetjih? Vabim vas pod kat, kjer je opisano, kako zbrati delovno in cenovno ugodno re\u0161itev, da zadovoljite ve\u010d potreb hkrati, ter kateri drobni poudarki jih je treba upo\u0161tevati za uspe\u0161no uvedbo te re\u0161itve.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nDecembra lani je eno podjetje odprlo novo pisarno za manj\u0161o KZ in naloga je bila organizirati celotno ra\u010dunalni\u0161ko infrastrukturo ob upo\u0161tevanju, da \u017ee imajo prenosnike za uporabnike in nekaj stre\u017enikov. Prenosniki so bili \u017ee nekaj let stari in so imeli ve\u010dinoma igralne konfiguracije z 8-16 GB RAM-a, ki se ve\u010dinoma niso obnesli ob obremenitvah CAD\/CAM aplikacij. Uporabniki morajo biti mobilni, saj pogosto potreboval delati ne iz pisarne. V pisarni se za vsak prenosnik dodatno kupi \u0161e monitor (tako delajo z grafiko). Pri tako postavljenih podatkih \u2014 edina optimalna, vendar zame tvegana re\u0161itev \u2014 vpeljati mo\u010dan terminalski stre\u017enik z zmogljivo profesionalno grafi\u010dno kartico in NVMe SSD diskom. <\/p>\n<h4>Prednosti grafi\u010dnega terminalskega stre\u017enika in dela preko RDP<\/h4>\n<p><\/p>\n<ul>\n<li>Na posameznih mo\u010dnej\u0161ih osebnih ra\u010dunalnikih ali grafi\u010dnih delovnih postajah ve\u010dino \u010dasa strojni viri niso izkori\u0161\u010deni niti za tretjino in stojijo brez dela, le kratek \u010das se uporabljajo v 35-100% svoje mo\u010di. Glavna u\u010dinkovitost zna\u0161a 5-20 odstotkov.<\/li>\n<li>A vendar je pogosto strojna oprema dale\u010d od najdra\u017ejega elementa, saj osnovne licence za grafi\u010dne ali CAD\/CAM programe pogosto stanejo od 5000 $, dodatne mo\u017enosti pa lahko dvignejo ceno na 10 000 $. Obi\u010dajno te programe v RDP seji za\u017eenemo brez te\u017eav, vendar je v\u010dasih potrebno dodati RDP opcijo ali poiskati na forumih, kaj vnesti v konfiguracijo ali register ter kako zagnati to programsko opremo v RDP seji. Pomembno je preveriti, ali na\u0161a programska oprema deluje preko RDP. <b>To je potrebno storiti na samem za\u010detku.<\/b> In to je preprosto: poskusimo se prijaviti preko RDP \u2013 \u010de se je program zagnal in delujejo vse osnovne funkcionalnosti, potem verjetno ne bo te\u017eav z licencami. \u010ce pa se prika\u017ee napaka, bomo pred realizacijo projekta s grafi\u010dnim terminalnim stre\u017enikom poiskali zadovoljivo re\u0161itev za nas.<\/li>\n<li>Prav tako je velika prednost podpora enake konfiguracije in specifi\u010dnih nastavitev, komponent in predlog, kar je pogosto te\u017eko uresni\u010dljivo za vse uporabnike PC-jev. Upravljanje, administracija in posodabljanje programske opreme je tudi \"brez zapletov\".<\/li>\n<\/ul>\n<p>\nNa splo\u0161no je veliko prednosti \u2013 poglejmo, kako se bo na\u0161e skoraj popolno re\u0161itev izkazalo v praksi.<\/p>\n<h3>Zbiramo stre\u017enik na podlagi rabljenih CISCO UCS-C220 M3 v2.<\/h3>\n<p>\nPrvotno je bilo na\u010drtovano, da kupimo novej\u0161i in zmogljivej\u0161i stre\u017enik s 256 GB DDR3 ECC pomnilnika in 10 GB ethernetom, vendar so rekli, da moramo malo prihraniti in se prilegati v prora\u010dun za terminalski stre\u017enik 1600 $. No, stranka ima vedno prav in prilagodimo se temu znesku:<\/p>\n<p>rabljeni CISCO UCS-C220 M3 v2 (2 X SIX CORE 2.10GHZ E5-2620 v2) 128GB DDR3 ECC \u2013 625 $<br \/>\n3.5&quot; 3TB sas 7200 \u0437 \u0421\u0428\u0410 \u0456\u0434 \u2014 2&#215;65$=130$<br \/>\nSSD M.2 2280 970 PRO, PCI-E 3.0 (x4) 512GB Samsung \u2013 200 $<br \/>\nGrafi\u010dna kartica QUADRO P2200 5120MB \u2013 470 $<br \/>\nAdapter Ewell PCI-E 3.0 to M.2 SSD (EW239) -10 $<br \/>\nSkupaj za stre\u017enik = 1435 $<\/p>\n<p>Sprva smo nameravali vzeti 1TB SSD in 10GB ethernet adapter \u2013 40 $, vendar se je izkazalo, da UPS za njune 2 stre\u017enika ni bilo, zato smo morali nekoliko pritisniti in kupiti UPS PowerWalker VI 2200 RLE -350 $.<\/p>\n<h3>Zakaj stre\u017enik in ne zmogljiv PC? Pojasnilo izbrane konfiguracije.<\/h3>\n<p>\nMnogi kratkovidni administratorji (\u017ee mnogokrat sem se sre\u010dal s tem) iz nekega razloga kupijo zmogljiv (pogosto igralni) PC, vanj namestijo 2-4 diske, ustvarijo RAID 1, ga ponosno imenujejo stre\u017enik in ga postavijo v kot pisarne. Seveda je celoten material \u2013 \"me\u0161anica\" dvomljive kakovosti. Zato bom podrobno razlo\u017eil, zakaj je bila pod tak prora\u010dun izbrana prav tak\u0161na konfiguracija.<\/p>\n<ol>\n<li>Zanesljivost!!! \u2014 vse stre\u017eni\u0161ke komponente so zasnovane in testirane za delovanje ve\u010d kot 5-10 let. Igralne mati\u010dne plo\u0161\u010de pa praviloma delujejo 3-5 let, pri \u010demer nekateri dosegajo celo stopnjo napake med garancijsko dobo, ki presega 5%. Na\u0161 stre\u017enik je od izjemno zanesljive blagovne znamke CISCO, tako da posebnih te\u017eav ni mogo\u010de predvideti in njihova verjetnost je dosti ni\u017eja kot pri stacionarnem PC-ju.<\/li>\n<li>Pomembni sestavni deli, kot je napajalnik, so podvojeni, in idealno bi bilo mo\u017eno napajati z dveh razli\u010dnih vodov - pri okvari enega napajalnika stre\u017enik nadaljuje z delovanjem.<\/li>\n<li>Pomnilnik ECC \u2014 malo kdo se danes spomni, da je bil pomnilnik ECC prvotno uveden za popravljanje ene bite napake, ki najpogosteje nastane zaradi vpliva kozmi\u010dnih \u017earkov, pri kapaciteti pomnilnika 128GB pa lahko napaka nastane ve\u010dkrat na leto. Pri stacionarnem PC-ju lahko opazimo zru\u0161itev programa, zmrzovanje itd., kar ni kriti\u010dno, vendar je cena napake na stre\u017eniku v\u010dasih zelo visoka (na primer napa\u010den vnos v BDP), v na\u0161em primeru pa je pri resni napaki potrebno ponovno zagnati in to lahko stane enodnevno delo ve\u010d oseb.<\/li>\n<li>Raz\u0161irljivost \u2014 pogosto se potreba podjetja po virih ve\u010dkrat pove\u010da v dveh letih in enostavno je dodati pomnilnik, trde diske, zamenjati procesorje (v na\u0161em primeru \u0161estjedrni E5-2620 na desetjedrni Xeon E5 2690 v2) \u2014 pri obi\u010dajnem PC-ju skoraj ni nobene raz\u0161irljivosti.<\/li>\n<li>Stre\u017eni\u0161ka oblika U1 \u2014 stre\u017eniki morajo stati v stre\u017enih prostorih! in v kompaktnih omarah, namesto da bi greli (do 1 kW toplote) in hrupili v kotu pisarne! Prav v novem uradu podjetja je bilo posebej namenjenega malo (3-6 enot) prostora v stre\u017eni\u0161ki sobi, enota za na\u0161 stre\u017enik pa je bila ravno dovolj.<\/li>\n<li>Oddaljeno: upravljanje in konzola \u2014 brez tega je normalno vzdr\u017eevanje stre\u017enika za oddaljeno! delo izjemno ote\u017eeno!<\/li>\n<li>128GB RAM \u2014 v T\u017d je bilo navedeno 8-10 uporabnikov, vendar bo v resnici le 5-6 so\u010dasnih sej \u2014 zato upo\u0161tevajo\u010d tipi\u010dno v tistem podjetju najve\u010djo porabo pomnilnika 2 uporabnika po 30-40GB = 70GB, in 4 uporabniki po 3-15GB = 36GB, + do 10GB za operacijski sistem, skupaj 116GB in 10% rezervirano (to vse v redkih primerih najve\u010dje uporabe. \u010ce pa bo primanjkovalo, bo kadar koli mo\u017eno dodati do 256GB. <\/li>\n<li>Grafi\u010dna kartica QUADRO P2200 5120MB \u2014 v povpre\u010dju na uporabnika v tem podjetju v <br \/>\n V oddaljeni seansi je bilo porabe grafi\u010dne pomnilnika od 0,3 GB do 1,5 GB, tako da 5 GB zadostuje. Izvorni podatki so bili pridobljeni z analogo, a manj zmogljivo re\u0161itev z i5\/64 GB\/Quadro P620 2 GB, ki je zadostovala za 3-4 uporabnike.<\/li>\n<li>SSD M.2 2280 970 PRO, PCI-E 3.0 (x4) 512GB Samsung \u2014 za so\u010dasno delovanje. <br \/>\n 8-10 uporabnikov, potrebna sta hitrost NVMe in zanesljivost SSD Samsung. Ta disk bo uporabljen za OS in aplikacije.<\/li>\n<li>2x3TB SAS \u2014 zdru\u017eimo v RAID 1, uporabljamo za obse\u017ene ali redko uporabljene lokalne podatke uporabnikov, pa tudi za varnostno kopiranje sistema in kriti\u010dnih lokalnih podatkov z diska NVMe.<\/li>\n<\/ol>\n<p>\nKonfiguracija je odobrena in kupljena, kmalu bo pri\u0161el trenutek resnice!<\/p>\n<h3>Sestava, nastavitev, namestitev in re\u0161evanje te\u017eav.<\/h3>\n<p>\n\u017de od za\u010detka nisem imel zaupanja, da je to 100% delujo\u010da re\u0161itev, saj sem lahko na kateremkoli koraku, od sestave do namestitve, zagona in pravilnega delovanja aplikacij obstal brez mo\u017enosti nadaljevanja, zato sem se dogovoril, da lahko stre\u017enik vrnem v dveh dneh, druge komponente pa lahko uporabim v alternativni re\u0161itvi. <\/p>\n<p>1 izmi\u0161ljena te\u017eava \u2014 grafi\u010dna kartica je profesionalna, polnoformatna! + nekaj mm, in kaj \u010de ne bo spravljena? 75 W \u2014 in kaj \u010de PCI re\u017ea ne bo zmogla? In kako narediti normalno hlajenje teh 75 W? A vendarle je \u0161la, zagnala se je, hlajenje je normalno (\u0161e posebej, \u010de se ventilatorji stre\u017enika nastavijo na vi\u0161je obrati). Ko sem jo name\u0161\u010dal, sem za zanesljivost 1 mm upognil nekaj (\u017ee ne pomnim \u010desa), in za bolj\u0161e hlajenje sem po kon\u010dnem nastavljanju odstranil folijo iz navodil z zgornje strani stre\u017enika, ki bi lahko poslab\u0161ala hlajenje skozi pokrov.<\/p>\n<p>2. preizku\u0161nja \u2014 NVMe disk preko adapterja morda ni bil prepoznan ali pa se sistem nanj ni namestil, in \u010de se je, se ni nalo\u017eil. Nenavadno je, da se je Windows namestil na NVMe disk, a se ni mogel zagnati, kar je logi\u010dno, saj BIOS (tudi posodobljen) za nalaganje NVMe ni hotel prepoznati. Nisem hotel uporabljati re\u0161itev, a ni bilo druge; tukaj je prisko\u010dil na pomo\u010d na\u0161 ljubljeni Habr in objava. <noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/472224\/\">o nalaganju z NVMe diska na legacy sistemih.<\/a><\/noindex> preneseno. <noindex><a rel=\"nofollow\" href=\"https:\/\/ua-opt.com\/BDU_v2.1.2020.027b.zip\">uporabni\u0161ko orodje Boot Disk Utility (BDUtility.exe).<\/a><\/noindex>, sem ustvaril USB z CloverBootManager po navodilih iz objave, nastavil USB v BIOS-u kot prvi za zagon in zdaj \u017ee nalagamo zaganjalnik z USB, Clover je uspe\u0161no prepoznal na\u0161 NVMe disk in \u010dez nekaj sekund se je samodejno zagnal! Lahko bi se igral z namestitvijo clover na na\u0161 RAID 3TB disk, a je bila \u017ee sobota zve\u010der in dela je bilo \u0161e za en dan, saj je do ponedeljka bilo treba ali vrniti stre\u017enik ali pustiti. Zagon USB sem pustil znotraj stre\u017enika, tam je bil prav toliko prostih USB-jev.<\/p>\n<p>3. skoraj neuspeh. Namestil sem Windows 2019 standard + RD storitve, namestil glavno aplikacijo, zaradi katere je bilo vse organizirano, in vse deluje odli\u010dno in dobesedno leti. <\/p>\n<p>Odli\u010dno! Peljem se domov in se pove\u017eem preko RDP, aplikacija se za\u017eene, vendar ob\u010dutim resno zastoje, gledam in v programu sporo\u010dilo \"vklju\u010den na\u010din soft\". Kaj?! I\u0161\u010dem novej\u0161e in super profesionalne gonilnike za grafi\u010dno kartico, jih namestim - rezultat ni\u010d, starej\u0161i gonilniki za P1000 tudi ne delujejo. In v tem \u010dasu notranji glas vse zafrkava \"a sem ti rekel \u2014 ne eksperimentiraj s sve\u017eimi \u2014 vzemi P1000\". A \u010das \u2014 je \u017ee zdavnaj no\u010d zunaj, s te\u017ekim srcem grem spat. Nedelja, vozim se v pisarno \u2014 v stre\u017enik vstavim Quadro P620 in tudi preko RDP ne deluje \u2014 MS, kaj se dogaja? I\u0161\u010dem po forumih \"2019 stre\u017enik in RDP\" \u2014 odgovor sem na\u0161el skoraj takoj. <\/p>\n<p>Izkazalo se je, da ker ve\u010dina ljudi zdaj uporablja monitorje z visoko lo\u010dljivostjo, ve\u010dina stre\u017enikov pa ne podpira teh lo\u010dljivosti preko vgrajenega grafi\u010dnega adapterja \u2014 je strojno pospe\u0161evanje privzeto onemogo\u010deno prek skupinskih politik. Citiram navodila za omogo\u010danje:<\/p>\n<ul>\n<li>Odprite orodje za urejanje skupinske politike iz nadzorne plo\u0161\u010de ali uporabite iskalno okno Windows (Windows tipka + R, nato vtipkajte gpedit.msc)<\/li>\n<li>Brskajte do: Lokalna ra\u010dunalni\u0161ka politikaKonfiguracija ra\u010dunalnikaAdministrativne predlogeWindows komponentiRemote Desktop ServicesRemote Desktop Session HostRemote Session Environment<\/li>\n<li>Nato omogo\u010dite \"Uporabi privzeti strojni grafi\u010dni adapter za vse seje storitev oddaljenega namizja\"<\/li>\n<\/ul>\n<p>\nPonovno se pokre\u0107emo \u2014 sve savr\u0161eno funkcioni\u0161e preko RDP-a. Menjamo grafi\u010dku kartu na P2200, ponovo radi! Sada kada smo sigurni da je re\u0161enje potpuno funkcionalno, dovedemo sve postavke servera do savr\u0161enstva, uvodimo ga u domenu, pode\u0161avamo pristup korisnicima i ostalo, stavljamo server u serveranu. Testiramo sa \u010ditavim timom nekoliko dana \u2014 sve radi savr\u0161eno, resursi servera su vi\u0161e nego dovoljni za sve zadatke, minimalni lag koji nastaje kao rezultat rada preko RDP-a nije primetan svim korisnicima. Odli\u010dno \u2014 zadatak je uspe\u0161no zavr\u0161en 100%.<\/p>\n<h3>Nekoliko stvari koje uti\u010du na uspeh implementacije grafi\u010dkog servera<\/h3>\n<p>\nPo\u0161to se u bilo kojoj fazi implementacije grafi\u010dkog servera u organizaciji mogu pojaviti podvodne prepreke koje mogu stvoriti situaciju sli\u010dnu onoj na slici sa pobeglim ribicama,<\/p>\n<p><img decoding=\"async\" alt=\"\u0421\u043e\u0431\u0438\u0440\u0430\u0435\u043c \u0441\u0435\u0440\u0432\u0435\u0440 \u0434\u043b\u044f \u0433\u0440\u0430\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 CAD\/CAM \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u043f\u043e RDP \u043d\u0430 \u0431\u0430\u0437\u0435 \u0431\u0443 CISCO UCS-C220 M3 v2\" src=\"\/wp-content\/uploads\/2020\/07\/4616a77434fe5c53e13b6c115653864b.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nu fazi planiranja potrebno je uraditi nekoliko jednostavnih koraka:<\/p>\n<ol>\n<li>Ciljna publika i zadaci \u2014 korisnici koji intenzivno rade sa grafikom i kojima je potrebno hardversko ubrzanje grafi\u010dke kartice. Uspeh na\u0161eg re\u0161enja se zasniva na tome da su potrebe korisnika grafi\u010dkih i CAD\/CAM programa ve\u0107 vi\u0161e od 10 godina zadovoljene s vi\u0161kova, a trenutno imamo rezervu snage koja prema\u0161uje potrebe vi\u0161e od 10 puta. Na primer, snaga GPU Quadro P2200 je vi\u0161e nego dovoljna za 10 korisnika, a \u010dak i kada nedostaje video memorije, grafi\u010dka karta koristi RAM, i za obi\u010dnog 3D developera takav mali pad brzine memorije prolazi neprime\u0107eno. Ali ako u zadacima korisnika postoje intenzivni ra\u010dunarsko te\u0161ki zadaci (rendering, prora\u010duni i sli\u010dno) koji \u010desto anga\u017euju 100% resursa \u2014 onda na\u0161e re\u0161enje nije pogodno, po\u0161to drugi korisnici u tim periodima ne mogu normalno raditi. Zato pa\u017eljivo analiziramo zadatke korisnika i trenutnu optere\u0107enost resursa (barem okvirno). Tako\u0111e obratimo pa\u017enju na koli\u010dinu prepisivanja na disk dnevno i ako je ona velika, prilagodimo servere ssd ili optane diskove za tu koli\u010dinu.<\/li>\n<li>Na osnovu broja korisnika biramo odgovaraju\u0107i server, grafi\u010dku kartu i diskove:\n<ul>\n<li>procesorji po formuli 1 jedro na uporabnika + 2,3 na OS, kljub temu vsak v enem trenutku ne uporablja enega ali najve\u010d dveh (pri redki obremenitvi modela) jeder; <\/li>\n<li>grafi\u010dna kartica - preverimo povpre\u010dno porabo video pomnilnika in GPU na uporabnika v seji RDP ter izberemo profesionalno! grafi\u010dno kartico; <\/li>\n<li>podobno ravnamo z RAM in diskom (zdaj lahko celo RAID nvme poceni izberemo).<\/li>\n<\/ul>\n<\/li>\n<li>Sk diligently preu\u010dujemo dokumentacijo za stre\u017enik (na sre\u010do imajo vsi blagovni stre\u017eniki popolno dokumentacijo) skladnost glede priklju\u010dkov, hitrosti, napajanja in podprtih tehnologij, kot tudi fizi\u010dne dimenzije in norme za odvajanje toplote dodatnih komponent.<\/li>\n<li>Preverimo normalno delovanje na\u0161ega programske opreme v ve\u010d sejah RDP, pa tudi odsotnost licen\u010dnih omejitev ter temeljito preverimo prisotnost potrebnih licenc. To vpra\u0161anje re\u0161ujemo pred prvimi koraki izvajanja implementacije. Kot je bilo omenjeno v komentarju cenjenega malefixa <br \/>\n&quot;\u2014 \u041b\u0438\u0446\u0435\u043d\u0437\u0438\u0438 \u043c\u043e\u0433\u0443\u0442 \u0431\u044b\u0442\u044c \u043f\u0440\u0438\u0432\u044f\u0437\u0430\u043d\u044b \u043a \u043a\u043e\u043b-\u0432\u0443 \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u0435\u0439 \u2014 \u0442\u043e\u0433\u0434\u0430 \u0432\u044b \u043d\u0430\u0440\u0443\u0448\u0430\u0435\u0442\u0435 \u043b\u0438\u0446\u0435\u043d\u0437\u0438\u044e.<br \/>\n\u2014 \u0421\u043e\u0444\u0442 \u043c\u043e\u0436\u0435\u0442 \u043d\u0435\u043a\u043e\u0440\u0440\u0435\u043a\u0442\u043d\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u043f\u0440\u0438 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u0438\u0445 \u0437\u0430\u043f\u0443\u0449\u0435\u043d\u043d\u044b\u0445 \u0438\u043d\u0441\u0442\u0430\u043d\u0441\u0430\u0445 \u2014 \u0441\u0442\u043e\u0438\u0442 \u0435\u043c\u0443 \u0445\u043e\u0442\u044c \u0432 \u043e\u0434\u043d\u043e\u043c \u043c\u0435\u0441\u0442\u0435 \u043f\u0438\u0441\u0430\u0442\u044c \u043c\u0443\u0441\u043e\u0440 \u0438\u043b\u0438 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u043d\u0435 \u0432 \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u0441\u043a\u0438\u0439 \u043f\u0440\u043e\u0444\u0438\u043b\u044c\/%temp%, \u0430 \u0432 \u0447\u0442\u043e-\u0442\u043e \u043e\u0431\u0449\u0435\u0435\u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0435 \u2014 \u0432\u0430\u043c \u043f\u043e\u0442\u043e\u043c \u0431\u0443\u0434\u0435\u0442 \u043e\u0447\u0435\u043d\u044c \u0432\u0435\u0441\u0435\u043b\u043e \u043e\u0442\u043b\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0443&quot;<\/li>\n<li>Premisli, kje bo name\u0161\u010den grafi\u010dni stre\u017enik, ne pozabi na UPS in prisotnost visoko hitrostnih ethernet priklju\u010dkov ter interneta (\u010de je potrebno), in skladnost s podnebnimi zahtevami stre\u017enika.<\/li>\n<li>\u010cas implementacije podalj\u0161amo najmanj na 2,5-3 tedne, saj lahko mnoge celo majhne potrebne komponente prihajajo do dveh tednov, poleg tega pa monta\u017ea in nastavitev traja ve\u010d dni \u2014 samo obi\u010dajno nalaganje stre\u017enika do OS lahko traja ve\u010d kot 5 minut. <\/li>\n<li>Opravimo pogovor z vodstvom in dobavitelji, da \u010de slu\u010dajno v nekem trenutku projekt ne gre ali ne gre tako, lahko izvedemo vra\u010dilo ali zamenjavo. <\/li>\n<li>Prav tako je bilo prijazno nakazano v <noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/509270\/#comment_21810968\">komentarju malefixa<\/a><\/noindex> <br \/>\npo vseh eksperimentih z nastavitvami \u2014 vse izbri\u0161emo in postavimo na novo. Tako:<br \/>\n\u2014 med eksperimentiranjem je treba dokumentirati vse kriti\u010dne nastavitve<br \/>\n\u2014 med instalacijo iz ni\u010d ponovno izvedete minimalne potrebne nastavitve (ki ste jih dokumentirali v prej\u0161njem koraku)\n<\/li>\n<li>Operacijski sistem (priporo\u010dljivo Windows Server 2019 \u2014 tam je kakovosten RDP) najprej namestimo v preskusnem na\u010dinu, nikakor ne v na\u010dinu evaluacije (to bo kasneje zahtevalo ponovno namestitev). \u0160ele po uspe\u0161nem zagonu se odlo\u010dimo o licencah in aktiviramo operacijski sistem. <\/li>\n<li>Pred uvedbo tudi izberemo iniciativno skupino za preverjanje delovanja in prihodnjim uporabnikom pojasnimo prednosti dela z grafi\u010dnim stre\u017enikom. \u010ce to storimo kasneje, pove\u010dujemo tveganje za prito\u017ebe, sabota\u017eo in neutemeljene negativne ocenitve.<\/li>\n<\/ol>\n<p>\nOb\u010dutek pri delu preko RDP se ne razlikuje od dela v lokalni seji. Pogosto celo pozabite, da delate nekje preko RDP \u2014 saj tudi video in ob\u010dasno videoklico v seji RDP delujeta brez opaznih zamud, ker ima ve\u010dina zdaj dostop do \u0161irokopasovnega interneta. Po hitrosti in funkcionalnosti RDP podjetje Microsoft \u0161e vedno prijetno presene\u010da, strojno pospe\u0161evanje 3D in ve\u010dmonitorni sistemi \u2014 vse, kar potrebujete za oddaljeno delo uporabnikov grafi\u010dnih, 3D in CAD\/CAM programov!<\/p>\n<p>Tako da v mnogih primerih namestitev grafi\u010dnega stre\u017enika glede na uvedeno re\u0161itev pomeni prednost in mobilnost pred 10 grafi\u010dnimi delovnimi postajami ali ra\u010dunalniki.<\/p>\n<p>P.S. \u041a\u0430\u043a \u043f\u0440\u043e\u0441\u0442\u043e \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0438\u0442\u044c\u0441\u044f \u0447\u0435\u0440\u0435\u0437 \u0438\u043d\u0442\u0435\u0440\u043d\u0435\u0442 \u043f\u043e RDP, \u0430 \u0442\u0430\u043a\u0436\u0435 \u043e\u043f\u0442\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0434\u043b\u044f RDP \u043a\u043b\u0438\u0435\u043d\u0442\u043e\u0432 \u2014 \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043f\u043e\u0434\u0441\u043c\u043e\u0442\u0440\u0435\u0442\u044c \u0432 \u0441\u0442\u0430\u0442\u044c\u0435 &quot;<noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/495596\/\">Delo na daljavo v pisarni. RDP, Port Knocking, Mikrotik: enostavno in varno.<\/a><\/noindex>\"<br \/>\n<br \/>Izvor: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/509270\/\">habr.com<\/a> <\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u041f\u043e\u0447\u0442\u0438 \u0443 \u043a\u0430\u0436\u0434\u043e\u0439 \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u0438 \u0441\u0435\u0439\u0447\u0430\u0441 \u043e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u0435\u0441\u0442\u044c \u043e\u0442\u0434\u0435\u043b \u0438\u043b\u0438 \u0433\u0440\u0443\u043f\u043f\u0430 \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0430\u044f \u0432 CAD\/CAM \u0438\u043b\u0438 \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u0434\u0438\u0437\u0430\u0439\u043d\u0435\u0440\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0430\u0445. \u042d\u0442\u0443 \u0433\u0440\u0443\u043f\u043f\u0443 \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u0435\u0439 \u043e\u0431\u044a\u0435\u0434\u0438\u043d\u044f\u0435\u0442 \u0441\u0435\u0440\u044c\u0451\u0437\u043d\u044b\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0436\u0435\u043b\u0435\u0437\u0443: \u043c\u043d\u043e\u0433\u043e \u043f\u0430\u043c\u044f\u0442\u0438 \u2014 64\u0413\u0411 \u0438 \u0431\u043e\u043b\u044c\u0448\u0435, \u043f\u0440\u043e\u0444\u0435\u0441\u0441\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u0432\u0438\u0434\u0435\u043e\u043a\u0430\u0440\u0442\u0430, \u0431\u044b\u0441\u0442\u0440\u044b\u0439 ssd, \u0438 \u0447\u0442\u043e\u0431\u044b \u0431\u044b\u043b\u043e \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0435. \u0417\u0430\u0447\u0430\u0441\u0442\u0443\u044e \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u0438 \u043f\u043e\u043a\u0443\u043f\u0430\u044e\u0442 \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u043c \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u044f\u043c \u0442\u0430\u043a\u0438\u0445 \u043e\u0442\u0434\u0435\u043b\u043e\u0432 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043c\u043e\u0449\u043d\u044b\u0445 \u041f\u041a (\u0438\u043b\u0438 \u0433\u0440\u0430\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0442\u0430\u043d\u0446\u0438\u0439) \u0438 \u043e\u0441\u0442\u0430\u043b\u044c\u043d\u044b\u043c \u043c\u0435\u043d\u0435\u0435 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":87314,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-87313","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sl\/blog\/administrirovanie\/sobiraem-server-dlya-graficheskih-i-cad-cam-prilozhenij-dlya-udalennoj-raboty-po-rdp-na-baze-bu-cisco-ucs-c220-m3-v2\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"sl_SI\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0421\u043e\u0431\u0438\u0440\u0430\u0435\u043c \u0441\u0435\u0440\u0432\u0435\u0440 \u0434\u043b\u044f \u0433\u0440\u0430\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 CAD\/CAM \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u043f\u043e RDP \u043d\u0430 \u0431\u0430\u0437\u0435 \u0431\u0443 CISCO UCS-C220 M3 v2 | ProHoster\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sl\/blog\/administrirovanie\/sobiraem-server-dlya-graficheskih-i-cad-cam-prilozhenij-dlya-udalennoj-raboty-po-rdp-na-baze-bu-cisco-ucs-c220-m3-v2\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-07-06T23:42:43+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-07-06T23:42:43+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Sestavljamo stre\u017enik za grafi\u010dne in CAD\/CAM aplikacije za oddaljeno delo preko RDP na osnovi rabljenega CISCO UCS-C220 M3 v2 | ProHoster","description":"","canonical_url":"https:\/\/prohoster.info\/sl\/blog\/administrirovanie\/sobiraem-server-dlya-graficheskih-i-cad-cam-prilozhenij-dlya-udalennoj-raboty-po-rdp-na-baze-bu-cisco-ucs-c220-m3-v2","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sl_SI","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0421\u043e\u0431\u0438\u0440\u0430\u0435\u043c \u0441\u0435\u0440\u0432\u0435\u0440 \u0434\u043b\u044f \u0433\u0440\u0430\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 CAD\/CAM \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u043f\u043e RDP \u043d\u0430 \u0431\u0430\u0437\u0435 \u0431\u0443 CISCO UCS-C220 M3 v2 | ProHoster","og:url":"https:\/\/prohoster.info\/sl\/blog\/administrirovanie\/sobiraem-server-dlya-graficheskih-i-cad-cam-prilozhenij-dlya-udalennoj-raboty-po-rdp-na-baze-bu-cisco-ucs-c220-m3-v2","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-07-06T23:42:43+00:00","article:modified_time":"2020-07-06T23:42:43+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"87313","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 13:54:15","updated":"2022-09-27 14:53:09","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/posts\/87313","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/comments?post=87313"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/posts\/87313\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/media\/87314"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/media?parent=87313"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/categories?post=87313"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sl\/wp-json\/wp\/v2\/tags?post=87313"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}