{"id":31230,"date":"2019-10-31T21:40:10","date_gmt":"2019-10-31T18:40:10","guid":{"rendered":"https:\/\/prohoster.info\/blog\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere\/"},"modified":"2019-10-31T21:40:10","modified_gmt":"2019-10-31T18:40:10","slug":"rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere","title":{"rendered":"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>N\u00eb k\u00ebt\u00eb artikull, do t\u00eb flasim p\u00ebr karakteristikat e pun\u00ebs s\u00eb grupeve All Flash AccelStor me nj\u00eb nga platformat m\u00eb t\u00eb njohura t\u00eb virtualizimit \u2013 VMware vSphere. N\u00eb ve\u00e7anti, do t\u00eb theksojm\u00eb parametrat q\u00eb do t\u00eb ndihmojn\u00eb n\u00eb maksimizimin e efektit nga p\u00ebrdorimi i nj\u00eb instrumenti t\u00eb till\u00eb t\u00eb fuqish\u00ebm si All Flash. <\/p>\n<p><\/p>\n<p><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/177f44f7e1c5f30c8c072af86b4f9999.jpg\" style=\"display:block;margin: 0 auto;\" \/><noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<p>Grupet All Flash AccelStor NeoSapphire\u2122 p\u00ebrb\u00ebjn\u00eb <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/professional-models\">nj\u00eb<\/a><\/noindex> ose <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/modeli-vysokoj-dostupnosti-ha\">dy<\/a><\/noindex> nj\u00ebsi n\u00eb baz\u00eb t\u00eb disqeve SSD me nj\u00eb qasje krejt\u00ebsisht t\u00eb ndryshme n\u00eb realizimin e konceptit t\u00eb ruajtjes s\u00eb t\u00eb dh\u00ebnave dhe organizimin e aksesit n\u00eb t\u00eb duke p\u00ebrdorur teknologjin\u00eb e tyre t\u00eb ve\u00e7ant\u00eb <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/flexiremap-technology\">FlexiRemap\u00ae<\/a><\/noindex> n\u00eb vend t\u00eb algoritmeve shum\u00eb t\u00eb njohura RAID. Grupet ofrojn\u00eb akses bllok p\u00ebr hostet p\u00ebrmes nd\u00ebrfaqeve Fibre Channel ose iSCSI. Drejt\u00ebsisht, mund t\u00eb theksohet se modelet me nd\u00ebrfaqe iSCSI gjithashtu kan\u00eb akses n\u00eb skedar\u00eb si nj\u00eb bonus t\u00eb k\u00ebndsh\u00ebm. Por n\u00eb k\u00ebt\u00eb artikull do t\u00eb fokusohemi n\u00eb p\u00ebrdorimin e protokolleve bllok si m\u00eb t\u00eb prodhueshm\u00ebt p\u00ebr All Flash.<\/p>\n<p><\/p>\n<p>I gjith\u00eb procesi i shp\u00ebrndarjes dhe konfigurimit t\u00eb m\u00ebtejsh\u00ebm t\u00eb bashk\u00ebpunimit midis grupit AccelStor dhe sistemit t\u00eb virtualizimit VMware vSphere mund t\u00eb ndahet n\u00eb disa etapa:<\/p>\n<p><\/p>\n<ul>\n<li>Realizimi i topologjis\u00eb s\u00eb lidhjes dhe konfigurimi i rrjetit SAN;<\/li>\n<li>Konfigurimi i grupit All Flash;<\/li>\n<li>Konfigurimi i hosteve ESXi;<\/li>\n<li>Konfigurimi i makinave t\u00eb virtualizuara.<\/li>\n<\/ul>\n<p><\/p>\n<p>Si pajisje p\u00ebr shembuj u p\u00ebrdor\u00ebn grupet AccelStor NeoSapphire\u2122 me nd\u00ebrfaqe Fibre Channel dhe me nd\u00ebrfaqe iSCSI. Si software baz\u00eb \u2013 VMware vSphere 6.7U1.<\/p>\n<p><\/p>\n<p>Para shp\u00ebrndarjes s\u00eb sistemeve t\u00eb p\u00ebrshkruara n\u00eb artikull, rekomandohet n\u00eb m\u00ebnyr\u00eb t\u00eb theksuar q\u00eb t\u00eb shqyrtohet dokumentacioni nga VMware n\u00eb lidhje me \u00e7\u00ebshtjet e performanc\u00ebs (<noindex><a rel=\"nofollow\" href=\"https:\/\/www.vmware.com\/content\/dam\/digitalmarketing\/vmware\/en\/pdf\/techpaper\/performance\/vsphere-esxi-vcenter-server-67-performance-best-practices.pdf\">Praktikat m\u00eb t\u00eb mira t\u00eb performanc\u00ebs p\u00ebr VMware vSphere 6.7<\/a><\/noindex> ) dhe konfigurimet iSCSI (<noindex>Praktikat m\u00eb t\u00eb mira p\u00ebr funksionimin e VMware vSphere n\u00eb iSCSI<\/noindex>)<\/p>\n<p><\/p>\n<h3><i><b>Topologjia e lidhjes dhe konfigurimi i rrjetit SAN<\/b><\/i><\/h3>\n<p><\/p>\n<p>Komponent\u00ebt kryesor\u00eb t\u00eb rrjetit SAN jan\u00eb adaptuesit HBA n\u00eb hostet ESXi, switch-at SAN dhe nj\u00ebsit\u00eb e grupit. Nj\u00eb topologji tipike e till\u00eb e rrjetit do t\u00eb dukej k\u00ebshtu:<\/p>\n<p><\/p>\n<p><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/0fa8f428d3120b551747e21d43d9095d.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>Me termin Switch kuptohet si nj\u00eb switch fizik i ve\u00e7ant\u00eb ose nj\u00eb grup switch-esh (Fabric), po ashtu edhe nj\u00eb pajisje e ndar\u00eb midis sh\u00ebrbimeve t\u00eb ndryshme (VSAN n\u00eb rastin e Fibre Channel dhe VLAN n\u00eb rastin e iSCSI). P\u00ebrdorimi i dy switch-ave t\u00eb pavarur\/Fabric do t\u00eb lejoj\u00eb p\u00ebrjashtimin e mund\u00ebsis\u00eb s\u00eb ndonj\u00eb pik\u00eb d\u00ebshtimi.<\/p>\n<p><\/p>\n<p>Koneksioni direkt i hosteve me grupin, edhe pse mb\u00ebshtetet, nuk rekomandohet n\u00eb asnj\u00eb m\u00ebnyr\u00eb. Performanca e grupeve All Flash \u00ebsht\u00eb mjaft e lart\u00eb. Dhe p\u00ebr maksimalizimin e shpejt\u00ebsis\u00eb, duhet t\u00eb aktivizohen t\u00eb gjitha portet e grupit. Prandaj, prania e t\u00eb pakt\u00ebn nj\u00eb switch-i midis hosteve dhe NeoSapphire\u2122 \u00ebsht\u00eb e domosdoshme.<\/p>\n<p><\/p>\n<p>Prania e dy porteve n\u00eb HBA-n\u00eb e hostit \u00ebsht\u00eb gjithashtu nj\u00eb k\u00ebrkes\u00eb e domosdoshme p\u00ebr arritjen e performanc\u00ebs maksimale dhe sigurimin e q\u00ebndrueshm\u00ebris\u00eb.<\/p>\n<p><\/p>\n<p>N\u00eb rastin e p\u00ebrdorimit t\u00eb nd\u00ebrfaqes Fibre Channel, k\u00ebrkohet konfigurimi i zonave p\u00ebr t\u00eb p\u00ebrjashtuar mund\u00ebsit\u00eb e kolizionit midis iniciator\u00ebve dhe targeteve. Zonat nd\u00ebrtohen sipas parimit 'nj\u00eb port iniciatori \u2013 nj\u00eb ose disa porte t\u00eb grupit'.<\/p>\n<p><\/p>\n<p>N\u00ebse p\u00ebrdoret lidhja p\u00ebrmes iSCSI n\u00eb rast t\u00eb p\u00ebrdorimit t\u00eb nj\u00eb switch-i t\u00eb ndar\u00eb me sh\u00ebrbime t\u00eb tjera, \u00ebsht\u00eb e domosdoshme t\u00eb izolohet trafiku i iSCSI brenda nj\u00eb VLAN-i t\u00eb ve\u00e7ant\u00eb. Gjithashtu, rekomandohet jasht\u00ebzakonisht aktivizimi i mb\u00ebshtetjes p\u00ebr Jumbo Frames (MTU = 9000) p\u00ebr t\u00eb rritur dimensionet e paketimeve n\u00eb rrjet dhe, k\u00ebshtu, p\u00ebr t\u00eb reduktuar sasin\u00eb e informacionit ndihm\u00ebs gjat\u00eb transferimit. Sidoqoft\u00eb, \u00ebsht\u00eb e r\u00ebnd\u00ebsishme t\u00eb kujtohet q\u00eb p\u00ebr funksionimin e duhur nevojitet t\u00eb ndryshohet parametri MTU n\u00eb t\u00eb gjith\u00eb komponent\u00ebt e rrjetit n\u00eb zinxhirin 'nisiator-switch-target'.<\/p>\n<p><\/p>\n<h3><i><b>Konfigurimi i grupit All Flash<\/b><\/i><\/h3>\n<p><\/p>\n<p>Grupi i dor\u00ebzohet klient\u00ebve me grupe tashm\u00eb t\u00eb formuara. <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/flexiremap-technology\">FlexiRemap\u00ae<\/a><\/noindex>. Prandaj, nuk nevojiten veprime p\u00ebr bashkimin e disqeve n\u00eb nj\u00eb struktur\u00eb t\u00eb vetme. Mjafton t\u00eb krijoni volume sipas madh\u00ebsis\u00eb s\u00eb k\u00ebrkuar dhe n\u00eb numrin e nevojsh\u00ebm.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/zn\/x9\/nc\/znx9ncuyd2rgm8-jfvwf620zaqg.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/d09f9847203773280bc605be1c8fbc67.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/wx\/8l\/ua\/wx8lualewtdkixfwg0petpxbsre.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/ddcdaeb16263f79536db68f9c6ae2cff.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>P\u00ebr leht\u00ebsim, \u00ebsht\u00eb e pranishme funksionaliteti i krijimit t\u00eb paketave p\u00ebr disa volume t\u00eb p\u00ebrcaktuar. Si rregull, krijohen volume 't\u00eb holl\u00eb', pasi kjo lejon nj\u00eb shpenzim m\u00eb t\u00eb arsyesh\u00ebm t\u00eb hap\u00ebsir\u00ebs s\u00eb disponueshme t\u00eb ruajtjes (duke p\u00ebrfshir\u00eb mb\u00ebshtetje p\u00ebr Space Reclamation). Nga perspektiva e performanc\u00ebs, diferenca midis volumeve 't\u00eb holl\u00eb' dhe 't\u00eb trash\u00eb' nuk e kalon 1%. Sidoqoft\u00eb, n\u00ebse \u00ebsht\u00eb e nevojshme t\u00eb 'nxirreni t\u00eb gjitha l\u00ebngjet' nga grupi, gjithmon\u00eb mund t\u00eb konvertoni \u00e7do volum 't\u00eb holl\u00eb' n\u00eb 't\u00eb trash\u00eb'. Por duhet t\u00eb kujtohet se nj\u00eb operacion i till\u00eb \u00ebsht\u00eb i pakthyesh\u00ebm.<\/p>\n<p><\/p>\n<p>M\u00eb pas mbetet \"t\u00eb publikoni\" volumin e krijuar dhe t\u00eb p\u00ebrcaktoni t\u00eb drejtat e aksesit n\u00eb to nga ana e hosteve p\u00ebrmes ACL (adresat IP p\u00ebr iSCSI dhe WWPN p\u00ebr FC) dhe ndarjes fizike p\u00ebrmes porteve t\u00eb arrays. P\u00ebr modelet iSCSI, kjo b\u00ebhet p\u00ebrmes krijimit t\u00eb Target.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/mw\/8y\/cg\/mw8ycgqngghoyuelortgysofswi.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/942d7ec437ad802ef828afa91bcde1f8.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/py\/xe\/28\/pyxe28gnrsxh_cx4ltjleogwsmw.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/f92d329b691d7b17380974253c8572ce.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>P\u00ebr modelet FC, publikimi realizohet p\u00ebrmes krijimit t\u00eb LUN p\u00ebr \u00e7do port t\u00eb arrays.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/qh\/u3\/bx\/qhu3bxhm-kqinygguz298izbw7e.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/554aef268d6b18069edd3531b2429db5.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/oh\/al\/ey\/ohaleyllpb-0bmot9kawc4-ssyg.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/a770a4d3e6090c5bfaab3dad5487ee5a.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>P\u00ebr t\u00eb p\u00ebrshpejtuar procesin e konfigurimit, hostet mund t\u00eb grupohen. N\u00eb fakt, n\u00ebse n\u00eb host p\u00ebrdoret nj\u00eb FC HBA me shum\u00eb porte (\u00e7ka ndodh shpesh n\u00eb praktik\u00eb), sistemi e njeh automatikisht se portet e k\u00ebtij HBA i takojn\u00eb nj\u00eb host unik p\u00ebr shkak t\u00eb WWPN-s\u00eb q\u00eb ndryshon me nj\u00ebsi. Po ashtu, p\u00ebr t\u00eb dyja nd\u00ebrfaqet mb\u00ebshtetet krijimi me grupe t\u00eb Target\/LUN.<\/p>\n<p><\/p>\n<p>Nj\u00eb v\u00ebrejtje e r\u00ebnd\u00ebsishme n\u00eb rastin e p\u00ebrdorimit t\u00eb nd\u00ebrfaqes iSCSI \u00ebsht\u00eb krijimi i disa targeteve p\u00ebr volumin p\u00ebr t\u00eb rritur performanc\u00ebn, pasi radhitja n\u00eb target nuk mund t\u00eb ndryshohet dhe do t\u00eb jet\u00eb n\u00eb t\u00eb v\u00ebrtet\u00eb nj\u00eb ngushtic\u00eb.<\/p>\n<p><\/p>\n<p><b><i><\/p>\n<h3>Konfigurimi i hosteve ESXi<\/h3>\n<p><\/i><\/b><\/p>\n<p><\/p>\n<p>Nga ana e hosteve ESXi, konfigurimi baz\u00eb kryhet sipas nj\u00eb skenari t\u00eb pritsh\u00ebm. Rendi i veprimeve p\u00ebr lidhjen iSCSI:<\/p>\n<p><\/p>\n<ol>\n<li>Shtoni Adapterin Software iSCSI (nuk k\u00ebrkohet, n\u00ebse \u00ebsht\u00eb shtuar m\u00eb par\u00eb ose n\u00eb rastin e p\u00ebrdorimit t\u00eb Adapterit Hardware iSCSI);<\/li>\n<li>Krijimi i vSwitch, p\u00ebrmes t\u00eb cilit do kaloj\u00eb trafiku i iSCSI, dhe shtimi n\u00eb t\u00eb i lidh\u00ebsit fizik\u00eb dhe VMkernal;<\/li>\n<li>Shtimi i adresave t\u00eb arrays n\u00eb Dynamic Discovery;<\/li>\n<li>Krijimi i Datastore<\/li>\n<\/ol>\n<p><\/p>\n<p><b>Disa v\u00ebrejtje t\u00eb r\u00ebnd\u00ebsishme:<\/b><\/p>\n<p><\/p>\n<blockquote>\n<ul>\n<li>N\u00eb p\u00ebrgjith\u00ebsi, natyrisht, mund t\u00eb p\u00ebrdoret edhe vSwitch ekzistues, por n\u00eb rastin e nj\u00eb vSwitch t\u00eb ve\u00e7ant\u00eb, menaxhimi i konfigurimeve t\u00eb hostit do t\u00eb jet\u00eb shum\u00eb m\u00eb i leht\u00eb.<\/li>\n<li>\u00cbsht\u00eb e nevojshme t\u00eb ndahen trafiku i Menaxhmentit dhe ai i iSCSI n\u00eb lidhje fizike t\u00eb ve\u00e7anta dhe\/ose VLAN p\u00ebr t\u00eb shmangur probleme me performanc\u00ebn.<\/li>\n<li>Adresat IP t\u00eb VMkernal dhe porteve p\u00ebrkat\u00ebse t\u00eb Arrays All Flash duhet t\u00eb jen\u00eb brenda t\u00eb nj\u00ebjt\u00ebs n\u00ebndeg\u00eb, p\u00ebrs\u00ebri p\u00ebr shkak t\u00eb \u00e7\u00ebshtjeve t\u00eb performanc\u00ebs.<\/li>\n<li>P\u00ebr t\u00eb siguruar disponueshm\u00ebri sipas rregullave t\u00eb VMware, vSwitch duhet t\u00eb ket\u00eb t\u00eb pakt\u00ebn dy lidh\u00ebs fizik\u00eb.<\/li>\n<li>N\u00ebse p\u00ebrdoren Jumbo Frames, \u00ebsht\u00eb e nevojshme t\u00eb ndryshohet MTU n\u00eb t\u00eb dyja vSwitch dhe VMkernal.<\/li>\n<li>Nuk \u00ebsht\u00eb e tep\u00ebrt t\u00eb kujtojm\u00eb se sipas rekomandimeve t\u00eb VMware p\u00ebr adapter\u00ebt fizik\u00eb, t\u00eb cil\u00ebt do t\u00eb p\u00ebrdoren p\u00ebr p\u00ebrcjelljen e trafikut iSCSI, \u00ebsht\u00eb thelb\u00ebsore t\u00eb konfigurohet Teaming and Failover. N\u00eb ve\u00e7anti, \u00e7do VMkernel duhet t\u00eb funksionoj\u00eb vet\u00ebm p\u00ebrmes nj\u00eb uplink, nd\u00ebrsa uplink-i i dyt\u00eb duhet t\u00eb kaloj\u00eb n\u00eb modalitetin unused. P\u00ebr q\u00ebllime q\u00ebndrueshm\u00ebrie, \u00ebsht\u00eb e nevojshme t\u00eb shtohet dy VMkernel, \u00e7do nj\u00ebri prej t\u00eb cil\u00ebve do t\u00eb funksionoj\u00eb p\u00ebrmes uplink-it t\u00eb tij.<\/li>\n<\/ul>\n<p>\n<\/p><\/blockquote>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/_h\/jb\/va\/_hjbvatnuhjwts4duy2epgb7bbi.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/b769fa87aa8552ed6dd775f9f9dcb1b5.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>VMkernel Adapter (vmk#)<br \/>\nPhysical Network Adapter (vmnic#)<\/p>\n<p>vmk1 (Storage01)<br \/>\nAdapter\u00ebt Aktiv\u00eb<br \/>\nvmnic2<br \/>\nAdapter\u00ebt e Pashfryt\u00ebzuar<br \/>\nvmnic3<\/p>\n<p>vmk2 (Storage02)<br \/>\nAdapter\u00ebt Aktiv\u00eb<br \/>\nvmnic3<br \/>\nAdapter\u00ebt e Pashfryt\u00ebzuar<br \/>\nvmnic2<\/p>\n<p>P\u00ebr lidhje p\u00ebrmes Fibre Channel, nuk k\u00ebrkohen veprime paraprake. Mund t\u00eb filloni menj\u00ebher\u00eb krijimin e Datastore.<\/p>\n<p><\/p>\n<p>Pas krijimit t\u00eb Datastore, sigurohuni q\u00eb politika Round Robin po p\u00ebrdoret p\u00ebr rrug\u00ebt drejt Target\/LUN si m\u00eb e performante.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/zh\/zr\/t1\/zhzrt15baoc1qlp0w6ds-mys3hu.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/621474aa13123cd44518b263f222e6b5.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>Blerja e konfigurimeve t\u00eb VMware parashikon p\u00ebrdorimin e k\u00ebsaj politike sipas skem\u00ebs: 1000 k\u00ebrkesa p\u00ebrmes rrug\u00ebs s\u00eb par\u00eb, 1000 k\u00ebrkesa t\u00eb tjera p\u00ebrmes rrug\u00ebs s\u00eb dyt\u00eb etj. Kjo nd\u00ebrveprim midis hostit dhe nj\u00eb matrice me dy kontroler\u00eb do t\u00eb jet\u00eb e pap\u00ebrshtatshme. Prandaj, sugjerojm\u00eb t\u00eb vendosni parametrin Round Robin policy = 1 p\u00ebrmes Esxcli\/PowerCLI.<\/p>\n<p>\n<b class=\"spoiler_title\">Parametrat<\/b><\/p>\n<p>P\u00ebr Esxcli:<\/p>\n<p><\/p>\n<ul>\n<li>Shfaq LUN-at e disponuesh\u00ebm<\/li>\n<\/ul>\n<p><\/p>\n<p><b>esxcli storage nmp device list<\/b><\/p>\n<p><\/p>\n<ul>\n<li>Kopjoni Emrin e Pajisjes<\/li>\n<li>Ndryshoni Politiken e Round Robin<\/li>\n<\/ul>\n<p><\/p>\n<p><b>esxcli storage nmp psp roundrobin deviceconfig set --type=iops --iops=1 --device=\"Device_ID\"<\/b><\/p>\n<p><\/p>\n<p>Shumica e aplikacioneve moderne jan\u00eb projektuar p\u00ebr shk\u00ebmbimin e paketave t\u00eb dh\u00ebnash me madh\u00ebsi t\u00eb madhe p\u00ebr t\u00eb maksimizuar shfryt\u00ebzimin e bandwidth dhe p\u00ebr t\u00eb reduktuar ngarkes\u00ebn mbi procesorin qendror. Prandaj, ESXi normalisht d\u00ebrgon k\u00ebrkesat e hyrjes\/daljes n\u00eb pajisjen e ruajtjes n\u00eb copa deri n\u00eb 32767KB. Megjithat\u00eb, p\u00ebr disa skenar\u00eb, shk\u00ebmbimi i m\u00eb shum\u00eb copave do t\u00eb ishte m\u00eb efikas. N\u00eb lidhje me matricoj AccelStor, k\u00ebto jan\u00eb skenar\u00ebt:<\/p>\n<p><\/p>\n<ul>\n<li>Makin\u00eb virtuale p\u00ebrdor UEFI n\u00eb vend t\u00eb Legacy BIOS<\/li>\n<li>P\u00ebrdor vSphere Replication<\/li>\n<\/ul>\n<p><\/p>\n<p>P\u00ebr k\u00ebto skenar\u00eb rekomandohet t\u00eb ndryshohet vlera e parametrin Disk.DiskMaxIOSize n\u00eb 4096.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/1g\/et\/3g\/1get3g8odkem1onrpkwjdilbnsi.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/f7072bb572580d9bd6077afab8c272ba.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>P\u00ebr lidhjet iSCSI, rekomandohet t\u00eb ndryshohet vlera e parametrin Login Timeout n\u00eb 30 (n\u00eb m\u00ebnyr\u00eb t\u00eb paracaktuar 5) p\u00ebr t\u00eb rritur stabilitetin e lidhjes dhe t\u00eb \u00e7aktivizohet vonesa e konfirmimeve t\u00eb paketave t\u00eb p\u00ebrcjella, DelayedAck. T\u00eb dy opsionet ndodhen n\u00eb vSphere Client: Host \u2192 Configure \u2192 Storage \u2192 Storage Adapters \u2192 Advanced Options p\u00ebr adapterin iSCSI.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/1y\/5_\/c8\/1y5_c80zsijgqtngo-9vt2zbbo8.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/e9700594d0074b5439dbb397c081dd48.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/bh\/yi\/tv\/bhyitvuujofnioaunwhzypx3fe0.png\"><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/c2dd6f3aaa6c0648763f66a94af2c251.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>Nj\u00eb aspekt mjaft delikat \u00ebsht\u00eb numri i volumeneve t\u00eb p\u00ebrdorura p\u00ebr datastore. \u00cbsht\u00eb e qart\u00eb se p\u00ebr thjesht\u00ebsin\u00eb e menaxhimit, ndjenja e krijimit t\u00eb nj\u00eb volumi t\u00eb madh p\u00ebr t\u00eb gjith\u00eb kapacitetin e array-t lind. Sidoqoft\u00eb, prania e disa volumeve dhe, p\u00ebr rrjedhoj\u00eb, e datastore-ve ndikon pozitivisht n\u00eb performanc\u00ebn totale (p\u00ebr m\u00eb shum\u00eb rreth radh\u00ebve m\u00eb posht\u00eb n\u00eb tekst). Prandaj, rekomandojm\u00eb krijimin e t\u00eb pakt\u00ebn dy volumesh.<\/p>\n<p><\/p>\n<p>S\u00eb fundmi, VMware k\u00ebshillonte q\u00eb numri i makinave virtuale n\u00eb nj\u00eb datastore t\u00eb kufizohej p\u00ebrs\u00ebri p\u00ebr t\u00eb arritur performanc\u00ebn m\u00eb t\u00eb lart\u00eb t\u00eb mundshme. Megjithat\u00eb tani, ve\u00e7an\u00ebrisht me p\u00ebrhapjen e VDI, kjo problematik\u00eb nuk \u00ebsht\u00eb m\u00eb aq e theksuar. Por kjo nuk e heq rregullin e vjet\u00ebr \u2014 shp\u00ebrndarjen e makinave virtuale q\u00eb k\u00ebrkojn\u00eb IO t\u00eb intensifikuar n\u00eb datastore t\u00eb ndryshme. P\u00ebr t\u00eb p\u00ebrcaktuar numrin optimal t\u00eb virtual\u00ebve n\u00eb nj\u00eb volum, nuk ka asgj\u00eb m\u00eb t\u00eb mir\u00eb se t\u00eb kryeni <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/zaprosit-demo\">testime ngarkese t\u00eb array-t All Flash AccelStor <\/a><\/noindex>brenda infrastruktur\u00ebs suaj.<\/p>\n<p><\/p>\n<h3><i><b>Konfigurimi i makinave virtuale<\/b><\/i><\/h3>\n<p><\/p>\n<p>Gjat\u00eb konfigurimit t\u00eb makinave virtuale, nuk ka k\u00ebrkesa t\u00eb ve\u00e7anta, p\u00ebrve\u00e7 se ato jan\u00eb krejt normale:<\/p>\n<p><\/p>\n<ul>\n<li>P\u00ebrdorimi i versionit maksimal t\u00eb mundsh\u00ebm t\u00eb VM (kompatibiliteti)<\/li>\n<li>T\u00eb jeni t\u00eb kujdessh\u00ebm n\u00eb p\u00ebrcaktimin e madh\u00ebsis\u00eb s\u00eb RAM-it n\u00eb vendosjen e dendur t\u00eb makinave virtuale, p\u00ebr shembull, n\u00eb VDI (pasi, n\u00eb m\u00ebnyr\u00eb t\u00eb paracaktuar, nj\u00eb skedari ndihm\u00ebs me madh\u00ebsi t\u00eb barabart\u00eb me RAM-in krijohet gjat\u00eb fillimit, i cili shpenzon kapacitetin e dobish\u00ebm dhe ndikon n\u00eb performanc\u00ebn p\u00ebrfundimtare)<\/li>\n<li>P\u00ebrdorni versionet m\u00eb t\u00eb fuqishme p\u00ebr sa i p\u00ebrket IO t\u00eb adapter\u00ebve: t\u00eb rrjetit si VMXNET 3 dhe SCSI si PVSCSI<\/li>\n<li>P\u00ebrdorni llojin e diskut Thick Provision Eager Zeroed p\u00ebr performanc\u00eb maksimale dhe Thin Provisioning p\u00ebr p\u00ebrdorimin m\u00eb efikas t\u00eb hap\u00ebsir\u00ebs s\u00eb ruajtjes<\/li>\n<li>Sa m\u00eb shum\u00eb t\u00eb jet\u00eb e mundur, kufizoni pun\u00ebn e makinave jo kritike p\u00ebr IO me ndihm\u00ebn e Virtual Disk Limit<\/li>\n<li>Sigurohuni t\u00eb instaloni VMware Tools <\/li>\n<\/ul>\n<p><\/p>\n<h3><i><b>V\u00ebrejtje mbi radh\u00ebt<\/b><\/i><\/h3>\n<p><\/p>\n<p>Rradha (ose Outstanding I\/Os) \u00ebsht\u00eb numri i k\u00ebrkesave p\u00ebr hyrje\/dalje (komandave SCSI), t\u00eb cilat presin p\u00ebr p\u00ebrpunim n\u00eb \u00e7do moment t\u00eb caktuar nga nj\u00eb pajisje\/aplikacion i caktuar. N\u00eb rast t\u00eb mbingarkes\u00ebs s\u00eb radh\u00ebs, jepet gabimi QFULL, i cili p\u00ebrfundimisht shprehet n\u00eb rritjen e parametrit latency. Kur p\u00ebrdoren sistemet e ruajtjes me disk (me spin), teorikisht sa m\u00eb e lart\u00eb t\u00eb jet\u00eb radha, aq m\u00eb e lart\u00eb \u00ebsht\u00eb performanca e tyre. Megjithat\u00eb, nuk duhet keqp\u00ebrdorur, pasi \u00ebsht\u00eb e leht\u00eb t\u00eb has\u00ebsh n\u00eb QFULL. N\u00eb rastin e sistemeve All Flash, nga nj\u00ebra an\u00eb, gjith\u00e7ka \u00ebsht\u00eb pak m\u00eb e thjesht\u00eb: pasi grupi ka vonesa shum\u00eb m\u00eb t\u00eb ulta dhe, p\u00ebr k\u00ebt\u00eb arsye, zakonisht nuk k\u00ebrkohet t\u00eb rregullohet ve\u00e7mas madh\u00ebsia e radh\u00ebs. Por nga ana tjet\u00ebr, n\u00eb disa skenar\u00eb p\u00ebrdorimi (nj\u00eb devijim i fort\u00eb n\u00eb k\u00ebrkesat p\u00ebr IO p\u00ebr mahnit\u00eb specifike virtuale, teste p\u00ebr performanc\u00ebn maksimale etj.) k\u00ebrkohet, n\u00ebse jo t\u00eb ndryshohet parametrat e radh\u00ebs, t\u00eb kuptohet se \u00e7far\u00eb treguesish mund t\u00eb arrihen dhe, m\u00eb e r\u00ebnd\u00ebsishmja, se cilat jan\u00eb m\u00ebnyrat.<\/p>\n<p><\/p>\n<p>N\u00eb vet\u00eb grupin All Flash AccelStor, nuk ka asnj\u00eb kufizim n\u00eb lidhje me volumet ose portet e hyrjes\/daljes. N\u00eb rast se \u00ebsht\u00eb e nevojshme, madje nj\u00eb volumi i vet\u00ebm mund t\u00eb marr\u00eb t\u00eb gjith\u00eb burimet e grupit. Kufizimi i vet\u00ebm p\u00ebr radh\u00ebt \u00ebsht\u00eb te targetet iSCSI. Pik\u00ebrisht p\u00ebr k\u00ebt\u00eb arsye u theksua m\u00eb lart nevoja p\u00ebr t\u00eb krijuar disa (n\u00eb m\u00ebnyr\u00eb ideale deri n\u00eb 8) targete p\u00ebr \u00e7do volum p\u00ebr t\u00eb tejkaluar k\u00ebt\u00eb kufizim. Po ashtu t\u00eb kujtojm\u00eb se grupet AccelStor jan\u00eb zgjidhje shum\u00eb performuese. Prandaj, duhet t\u00eb p\u00ebrdoren t\u00eb gjitha portet nd\u00ebrfaq\u00ebsore t\u00eb sistemit p\u00ebr t\u00eb arritur shpejt\u00ebsin\u00eb maksimale.<\/p>\n<p><\/p>\n<p>Nga ana e host-it ESXi, situata \u00ebsht\u00eb krejt\u00ebsisht ndryshe. I gjith\u00eb hosti praktikisht p\u00ebrdor qasje t\u00eb barabart\u00eb n\u00eb burime p\u00ebr t\u00eb gjith\u00eb pjes\u00ebmarr\u00ebsit. Prandaj, ekzistojn\u00eb radh\u00eb t\u00eb ve\u00e7anta IO p\u00ebr sistemin operativ mik dhe HBA. Radh\u00ebt p\u00ebr sistemin operativ mik kombinohen nga radh\u00ebt p\u00ebr adaptorin virtual SCSI dhe diskun virtual:<\/p>\n<p><\/p>\n<p><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/e6033427e6f554490c9a6460574b7f6e.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>Radha p\u00ebr HBA varet nga lloji\/sistemi konkret:<\/p>\n<p><\/p>\n<p><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/a0b078e63bdf8f306a25bfecd1310cb0.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>Performanca p\u00ebrfundimtare e makin\u00ebs virtuale do t\u00eb p\u00ebrcaktohet nga vlera m\u00eb e vog\u00ebl e treguesit t\u00eb radh\u00ebs (Queue Depth limit) midis komponent\u00ebve t\u00eb host-it. <\/p>\n<p><\/p>\n<p>Me k\u00ebto vlera, mund t\u00eb vler\u00ebsojm\u00eb treguesit e performanc\u00ebs q\u00eb mund t\u00eb arrijm\u00eb n\u00eb nj\u00eb konfigurim t\u00eb caktuar. P\u00ebr shembull, d\u00ebshirojm\u00eb t\u00eb dim\u00eb performanc\u00ebn teorike t\u00eb nj\u00eb maine virtuale (pa u lidhur me blokun) me latency 0.5ms. At\u00ebher\u00eb IOPS e saj = (1,000\/latency) * Outstanding I\/Os (Limiti i Thell\u00ebsis\u00eb s\u00eb Radh\u00ebs)<\/p>\n<p>\n<b class=\"spoiler_title\">Shembuj<\/b><\/p>\n<p><b>Shembulli 1<\/b><\/p>\n<p><\/p>\n<ul>\n<li>FC Emulex HBA Adapter<\/li>\n<li>Nj\u00eb VM n\u00eb datastore<\/li>\n<li>VMware Paravirtual SCSI Adapter<\/li>\n<\/ul>\n<p><\/p>\n<p>K\u00ebtu, Limiti i Thell\u00ebsis\u00eb s\u00eb Radh\u00ebs p\u00ebrcaktohet nga Emulex HBA. Prandaj IOPS = (1000\/0.5)*32 = 64K<\/p>\n<p><\/p>\n<p><b>Shembulli 2<\/b><\/p>\n<p><\/p>\n<ul>\n<li>VMware iSCSI Software Adapter<\/li>\n<li>Nj\u00eb VM n\u00eb datastore<\/li>\n<li>VMware Paravirtual SCSI Adapter<\/li>\n<\/ul>\n<p><\/p>\n<p>K\u00ebtu, Limiti i Thell\u00ebsis\u00eb s\u00eb Radh\u00ebs p\u00ebrcaktohet nga Paravirtual SCSI Adapter. Prandaj IOPS = (1000\/0.5)*64 = 128K<\/p>\n<p><\/p>\n<p>Modelet kryesore t\u00eb All Flash arrays AccelStor (p.sh., <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/product\/neosapphire-p710\">P710<\/a><\/noindex>) jan\u00eb n\u00eb gjendje t\u00eb ofrojn\u00eb performanc\u00eb 700K IOPS n\u00eb shkrim me bllok 4K. Me k\u00ebt\u00eb madh\u00ebsi blloku, \u00ebsht\u00eb e qart\u00eb se nj\u00eb maine virtuale nuk mund t\u00eb ngarkoj\u00eb nj\u00eb array t\u00eb till\u00eb. Kjo k\u00ebrkon 11 (p\u00ebr shembull 1) ose 6 (p\u00ebr shembull 2) makina virtuale.<\/p>\n<p><\/p>\n<p>Si rezultat, me konfigurimin e duhur t\u00eb t\u00eb gjitha komponent\u00ebve t\u00eb p\u00ebrshkruar t\u00eb qendr\u00ebs virtuale, mund t\u00eb arrijm\u00eb rezultate shum\u00eb impresive n\u00eb aspektin e performanc\u00ebs.<\/p>\n<p><\/p>\n<p><img decoding=\"async\" alt=\"Rekomandime p\u00ebr konfigurimin e AFA AccelStor n\u00eb pun\u00eb me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/eee93cccf16539410695c6f79d94deda.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p><i>4K Random, 70% Lexo\/30% Shkruaj<\/i><\/p>\n<p><\/p>\n<p>N\u00eb t\u00eb v\u00ebrtet\u00eb, bota reale \u00ebsht\u00eb shum\u00eb m\u00eb e komplikuar p\u00ebr ta p\u00ebrshkruar me nj\u00eb formul\u00eb t\u00eb thjesht\u00eb. N\u00eb nj\u00eb host gjithmon\u00eb ndodhen shum\u00eb makina virtuale me konfigurime dhe k\u00ebrkesa t\u00eb ndryshme p\u00ebr IO. Po ashtu, p\u00ebrpunimi i hyrjeve\/daljeve menaxhohet nga procesori i hostit, fuqia e t\u00eb cilit nuk \u00ebsht\u00eb e pafundme. k\u00ebshtu q\u00eb, p\u00ebr t\u00eb zbuluar potencialin e plot\u00eb t\u00eb <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/product\/neosapphire-p710\">modelit P710<\/a><\/noindex> n\u00eb realitet do t\u00eb nevojiten t\u00eb pakt\u00ebn tre hoste. P\u00ebr m\u00eb tep\u00ebr, aplikacionet q\u00eb funksionojn\u00eb brenda makinave virtuale sjellin ndihma t\u00eb tyre. Prandaj, p\u00ebr nj\u00eb sizing t\u00eb sakt\u00eb, ne sugjerojm\u00eb <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/zaprosit-demo\">t\u00eb p\u00ebrdorni verifikimin p\u00ebr t\u00eb testuar modelet<\/a><\/noindex> All Flash arrays <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/\">AccelStor<\/a><\/noindex> brenda infrastruktur\u00ebs s\u00eb klientit n\u00eb detyrat reale t\u00eb tanishme.<\/p>\n<p>Burimi: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/accelstor\/blog\/447390\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0412 \u0440\u0430\u043c\u043a\u0430\u0445 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0445\u043e\u0442\u0435\u043b\u043e\u0441\u044c \u0431\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u0442\u044c \u043e\u0431 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044f\u0445 \u0440\u0430\u0431\u043e\u0442\u044b All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u043e\u0432 AccelStor \u0441 \u043e\u0434\u043d\u043e\u0439 \u0438\u0437 \u043f\u043e\u043f\u0443\u043b\u044f\u0440\u043d\u0435\u0439\u0448\u0438\u0445 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u2013 VMware vSphere. \u0412 \u0447\u0430\u0441\u0442\u043d\u043e\u0441\u0442\u0438, \u0430\u043a\u0446\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043d\u0430 \u0442\u0435\u0445 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u0430\u0445, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u044d\u0444\u0444\u0435\u043a\u0442 \u043e\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0442\u0430\u043a\u043e\u0433\u043e \u043c\u043e\u0449\u043d\u043e\u0433\u043e \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u0430, \u043a\u0430\u043a All Flash. All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u044b AccelStor NeoSapphire\u2122 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0442 \u0441\u043e\u0431\u043e\u0439 \u043e\u0434\u043d\u043e \u0438\u043b\u0438 \u0434\u0432\u0443\u0445 \u043d\u043e\u0434\u043e\u0432\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":23196,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-31230","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0412 \u0440\u0430\u043c\u043a\u0430\u0445 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0445\u043e\u0442\u0435\u043b\u043e\u0441\u044c \u0431\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u0442\u044c \u043e\u0431 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044f\u0445 \u0440\u0430\u0431\u043e\u0442\u044b All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u043e\u0432 AccelStor \u0441 \u043e\u0434\u043d\u043e\u0439 \u0438\u0437 \u043f\u043e\u043f\u0443\u043b\u044f\u0440\u043d\u0435\u0439\u0448\u0438\u0445 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u2013 VMware vSphere.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2\" \/>\n\t\t<meta property=\"og:locale\" content=\"sq_AL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0438 \u043f\u043e \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0435 AFA AccelStor \u043f\u0440\u0438 \u0440\u0430\u0431\u043e\u0442\u0435 \u0441 VMware vSphere | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0412 \u0440\u0430\u043c\u043a\u0430\u0445 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0445\u043e\u0442\u0435\u043b\u043e\u0441\u044c \u0431\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u0442\u044c \u043e\u0431 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044f\u0445 \u0440\u0430\u0431\u043e\u0442\u044b All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u043e\u0432 AccelStor \u0441 \u043e\u0434\u043d\u043e\u0439 \u0438\u0437 \u043f\u043e\u043f\u0443\u043b\u044f\u0440\u043d\u0435\u0439\u0448\u0438\u0445 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u2013 VMware vSphere.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T18:40:10+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T18:40:10+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Rrekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb pun\u00ebs me VMware vSphere | ProHoster","description":"N\u00eb kuad\u00ebr t\u00eb k\u00ebtij artikulli, do t\u00eb doja t\u00eb flisja p\u00ebr karakteristikat e funksionimit t\u00eb All Flash arrays AccelStor me nj\u00eb nga platformat m\u00eb t\u00eb popullarizuara t\u00eb virtualizimit \u2013 VMware vSphere.","canonical_url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sq_AL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0438 \u043f\u043e \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0435 AFA AccelStor \u043f\u0440\u0438 \u0440\u0430\u0431\u043e\u0442\u0435 \u0441 VMware vSphere | ProHoster","og:description":"\u0412 \u0440\u0430\u043c\u043a\u0430\u0445 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0445\u043e\u0442\u0435\u043b\u043e\u0441\u044c \u0431\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u0442\u044c \u043e\u0431 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044f\u0445 \u0440\u0430\u0431\u043e\u0442\u044b All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u043e\u0432 AccelStor \u0441 \u043e\u0434\u043d\u043e\u0439 \u0438\u0437 \u043f\u043e\u043f\u0443\u043b\u044f\u0440\u043d\u0435\u0439\u0448\u0438\u0445 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u2013 VMware vSphere.","og:url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T18:40:10+00:00","article:modified_time":"2019-10-31T18:40:10+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"31230","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-21 05:09:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 03:20:31","updated":"2026-01-21 05:09:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/31230","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/comments?post=31230"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/31230\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media\/23196"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media?parent=31230"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/categories?post=31230"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/tags?post=31230"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}