{"id":31230,"date":"2019-10-31T21:40:10","date_gmt":"2019-10-31T18:40:10","guid":{"rendered":"https:\/\/prohoster.info\/blog\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere\/"},"modified":"2019-10-31T21:40:10","modified_gmt":"2019-10-31T18:40:10","slug":"rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere","title":{"rendered":"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>N\u00eb kuad\u00ebr t\u00eb k\u00ebtij artikulli, do t\u00eb doja t\u00eb flisja p\u00ebr karakteristikat e pun\u00ebs s\u00eb grupeve All Flash AccelStor me nj\u00eb nga platformat m\u00eb t\u00eb njohura t\u00eb virtualizimit \u2013 VMware vSphere. N\u00eb ve\u00e7anti, do t\u00eb theksoj parametrat q\u00eb do t\u00eb ndihmojn\u00eb p\u00ebr t\u00eb arritur maksimumin nga p\u00ebrdorimi i nj\u00eb mjeti t\u00eb till\u00eb t\u00eb fuqish\u00ebm si All Flash. <\/p>\n<p><\/p>\n<p><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/177f44f7e1c5f30c8c072af86b4f9999.jpg\" style=\"display:block;margin: 0 auto;\" \/><noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<p>Grupet All Flash AccelStor NeoSapphire\u2122 p\u00ebrb\u00ebhen nga <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/professional-models\">nj\u00eb<\/a><\/noindex> ose <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/modeli-vysokoj-dostupnosti-ha\">dy<\/a><\/noindex> nj\u00ebsit\u00eb me baz\u00eb SSD me nj\u00eb qasje thelb\u00ebsisht t\u00eb ndryshme n\u00eb realizimin e konceptit t\u00eb ruajtjes s\u00eb t\u00eb dh\u00ebnave dhe organizimin e aksesit n\u00eb to duke p\u00ebrdorur teknologjin\u00eb e vet\u00eb <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/flexiremap-technology\">FlexiRemap\u00ae<\/a><\/noindex> n\u00eb vend t\u00eb algorithmeve shum\u00eb t\u00eb njohura t\u00eb RAID. Grupet ofrojn\u00eb qasje n\u00eb bllok p\u00ebr hostet p\u00ebrmes bordeve Fibre Channel ose iSCSI. P\u00ebr t\u00eb drejtat e drejt\u00ebsis\u00eb, duhet t'i kushtohet v\u00ebmendje se modelet me nd\u00ebrfaqen iSCSI gjithashtu kan\u00eb qasje n\u00eb skedar\u00eb si nj\u00eb bonus t\u00eb k\u00ebndsh\u00ebm. Por n\u00eb kuad\u00ebr t\u00eb k\u00ebtij artikulli ne do t\u00eb fokusojm\u00eb n\u00eb p\u00ebrdorimin e protokolleve t\u00eb bllokut si m\u00eb t\u00eb prodhuara p\u00ebr All Flash.<\/p>\n<p><\/p>\n<p>Procesi i instalimit dhe konfigurimit t\u00eb ndihm\u00ebs s\u00eb p\u00ebrbashk\u00ebt p\u00ebr grumbullin AccelStor dhe sistemin e virtualizimit VMware vSphere mund t\u00eb ndahet n\u00eb disa faza:<\/p>\n<p><\/p>\n<ul>\n<li>Realizimi i topologjis\u00eb s\u00eb lidhjes dhe konfigurimi i rrjetit SAN;<\/li>\n<li>Konfigurimi i grumbullit All Flash;<\/li>\n<li>Konfigurimi i hosteve ESXi;<\/li>\n<li>Konfigurimi i makinave virtuale.<\/li>\n<\/ul>\n<p><\/p>\n<p>Si pajisje p\u00ebr shembuj ishin p\u00ebrdorur grumbuj AccelStor NeoSapphire\u2122 me nd\u00ebrfaqe Fibre Channel dhe me nd\u00ebrfaqe iSCSI. Si sistem baz\u00eb \u2013 VMware vSphere 6.7U1.<\/p>\n<p><\/p>\n<p>Para se t\u00eb kryhet instalimi i sistemeve t\u00eb p\u00ebrshkruara n\u00eb k\u00ebt\u00eb artikull, rekomandohet fort t\u00eb njiheni me dokumentacionin nga VMware n\u00eb lidhje me \u00e7\u00ebshtjet e performanc\u00ebs (<noindex><a rel=\"nofollow\" href=\"https:\/\/www.vmware.com\/content\/dam\/digitalmarketing\/vmware\/en\/pdf\/techpaper\/performance\/vsphere-esxi-vcenter-server-67-performance-best-practices.pdf\">Performance Best Practices for VMware vSphere 6.7<\/a><\/noindex> ) dhe konfigurimet iSCSI (<noindex>Best Practices For Running VMware vSphere On iSCSI<\/noindex>)<\/p>\n<p><\/p>\n<h3><i><b>Topologjia e lidhjes dhe konfigurimi i rrjetit SAN<\/b><\/i><\/h3>\n<p><\/p>\n<p>Komponent\u00ebt kryesor\u00eb t\u00eb rrjetit SAN jan\u00eb adaptator\u00ebt HBA n\u00eb hostet ESXi, switch-\u00ebt SAN dhe ndodhat e grumbullit. Topologjia tipike e till\u00eb do t\u00eb dukej k\u00ebshtu:<\/p>\n<p><\/p>\n<p><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/0fa8f428d3120b551747e21d43d9095d.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>Termi Switch p\u00ebrfshin si nj\u00eb komutator fizik t\u00eb ve\u00e7ant\u00eb apo nj\u00eb grup komutator\u00ebsh (Fabric), ashtu edhe nj\u00eb pajisje q\u00eb ndahet mes sh\u00ebrbimeve t\u00eb ndryshme (VSAN p\u00ebr Fibre Channel dhe VLAN p\u00ebr iSCSI). P\u00ebrdorimi i dy komutator\u00ebve\/ Fabric t\u00eb pavarur do t\u00eb eliminoj\u00eb nj\u00eb pik\u00eb t\u00eb mundshme d\u00ebshtimi.<\/p>\n<p><\/p>\n<p>Megjith\u00ebse nd\u00ebrlidhja direkte e hosteve me array-in mb\u00ebshtetet, ajo \u00ebsht\u00eb ekstremisht e pap\u00ebrshtatshme. Performanca e arrays All Flash \u00ebsht\u00eb mjaft e lart\u00eb. Dhe p\u00ebr maksimumin e shpejt\u00ebsis\u00eb nevojitet angazhimi i t\u00eb gjitha porteve t\u00eb array-it. Prandaj, pranija e t\u00eb pakt\u00ebn nj\u00eb komutatori midis hosteve dhe NeoSapphire\u2122 \u00ebsht\u00eb e nevojshme.<\/p>\n<p><\/p>\n<p>Prania e dy porteve n\u00eb HBA-n\u00eb e hostit gjithashtu \u00ebsht\u00eb nj\u00eb k\u00ebrkes\u00eb e domosdoshme p\u00ebr arritjen e performanc\u00ebs maksimale dhe p\u00ebr t\u00eb siguruar q\u00ebndrueshm\u00ebrin\u00eb ndaj d\u00ebshtimeve.<\/p>\n<p><\/p>\n<p>N\u00eb rastin e p\u00ebrdorimit t\u00eb nd\u00ebrfaqes Fibre Channel, nevojitet konfigurimi i zonimit p\u00ebr t\u00eb eliminuar mund\u00ebsit\u00eb e kolizionit midis iniciator\u00ebve dhe targeteve. Zonat ndahen n\u00eb p\u00ebrputhje me parimin \"nj\u00eb port iniciatori \u2013 nj\u00eb ose disa porte t\u00eb array-it\".<\/p>\n<p><\/p>\n<p>N\u00eb rastin e p\u00ebrdorimit t\u00eb lidhjes p\u00ebrmes iSCSI me nj\u00eb switch t\u00eb ndar\u00eb nga sh\u00ebrbime t\u00eb tjera, \u00ebsht\u00eb thelb\u00ebsore t\u00eb izolohet trafiku i iSCSI brenda nj\u00eb VLAN t\u00eb ve\u00e7ant\u00eb. Gjithashtu, rekomandohet fuqish\u00ebm aktivizimi i mb\u00ebshtetjes p\u00ebr Jumbo Frames (MTU = 9000) p\u00ebr t\u00eb rritur dimensionet e pakot n\u00eb rrjet dhe, k\u00ebshtu, p\u00ebr t\u00eb reduktuar sasin\u00eb e informacionit administrativ gjat\u00eb transferimit. Megjithat\u00eb, \u00ebsht\u00eb e r\u00ebnd\u00ebsishme t\u00eb mbahet mend se p\u00ebr funksionimin e duhur, parametri MTU duhet t\u00eb ndryshohet n\u00eb t\u00eb gjitha komponent\u00ebt e rrjetit n\u00eb zinxhirin \"inisiator-switch-target\".<\/p>\n<p><\/p>\n<h3><i><b>Konfigurimi i grumbullit All Flash<\/b><\/i><\/h3>\n<p><\/p>\n<p>Grumbulli \u00ebsht\u00eb i dor\u00ebzuar klient\u00ebve me grupe tashm\u00eb t\u00eb formuara <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/flexiremap-technology\">FlexiRemap\u00ae<\/a><\/noindex>. Prandaj, nuk ka nevoj\u00eb t\u00eb nd\u00ebrmerrni veprime p\u00ebr t\u00eb bashkuar drives n\u00eb nj\u00eb struktur\u00eb t\u00eb vetme. Mjafton t\u00eb krijoni volume t\u00eb nevojsh\u00ebm p\u00ebr madh\u00ebsin\u00eb dhe n\u00eb numrin e nevojsh\u00ebm.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/zn\/x9\/nc\/znx9ncuyd2rgm8-jfvwf620zaqg.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/d09f9847203773280bc605be1c8fbc67.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/wx\/8l\/ua\/wx8lualewtdkixfwg0petpxbsre.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/ddcdaeb16263f79536db68f9c6ae2cff.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>P\u00ebr leht\u00ebsi, ekziston funksionaliteti p\u00ebr krijimin e pakove t\u00eb disa volumesh me nj\u00eb v\u00ebllim t\u00eb caktuar. N\u00eb parazgjedhje krijohen volumet \"t\u00eb holl\u00eb\", pasi kjo lejon nj\u00eb shp\u00ebrndarje m\u00eb eficiente t\u00eb hap\u00ebsir\u00ebs s\u00eb ruajtjes s\u00eb disponueshme (duke p\u00ebrfshir\u00eb mb\u00ebshtetje p\u00ebr Reclamation t\u00eb Hap\u00ebsir\u00ebs). Nga k\u00ebndv\u00ebshtrimi i performanc\u00ebs, ndryshimi midis volumesh \"t\u00eb holl\u00eb\" dhe \"t\u00eb trash\u00eb\" nuk e tejkalon 1%. Megjithat\u00eb, n\u00ebse k\u00ebrkoni t\u00eb nxirrni maksimumin nga grila, gjithmon\u00eb mund ta konvertoni \u00e7do volum \"t\u00eb holl\u00eb\" n\u00eb \"t\u00eb trash\u00eb\". Por duhet t\u00eb mbani mend se kjo operacion \u00ebsht\u00eb e pakthyeshme.<\/p>\n<p><\/p>\n<p>Pastaj mbetet t\u00eb \"publikoni\" volumet e krijuara dhe t\u00eb caktoni t\u00eb drejtat e qasjes nga ana e hosteve p\u00ebrmes ACL (adresat IP p\u00ebr iSCSI dhe WWPN p\u00ebr FC) dhe ndarjes fizike sipas porteve t\u00eb gril\u00ebs. P\u00ebr modelet iSCSI, kjo b\u00ebhet p\u00ebrmes krijimit t\u00eb Target.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/mw\/8y\/cg\/mw8ycgqngghoyuelortgysofswi.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/942d7ec437ad802ef828afa91bcde1f8.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/py\/xe\/28\/pyxe28gnrsxh_cx4ltjleogwsmw.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/f92d329b691d7b17380974253c8572ce.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>P\u00ebr modelet FC, publikimi ndodh p\u00ebrmes krijimit t\u00eb LUN p\u00ebr \u00e7do port t\u00eb gril\u00ebs.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/qh\/u3\/bx\/qhu3bxhm-kqinygguz298izbw7e.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/554aef268d6b18069edd3531b2429db5.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/oh\/al\/ey\/ohaleyllpb-0bmot9kawc4-ssyg.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/a770a4d3e6090c5bfaab3dad5487ee5a.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>P\u00ebr t\u00eb p\u00ebrshpejtuar procesin e konfigurimit, host-\u00ebt mund t\u00eb grupohen. Madje, n\u00ebse n\u00eb host p\u00ebrdoret nj\u00eb FC HBA me disa porte (\u00e7ka ndodh m\u00eb s\u00eb shumti n\u00eb praktik\u00eb), sistemi e identifikon automatikisht q\u00eb portet e k\u00ebsaj HBA i p\u00ebrkasin nj\u00eb host-i t\u00eb vet\u00ebm p\u00ebrmes WWPN, t\u00eb cilat ndryshojn\u00eb me nj\u00ebsi. Po ashtu, p\u00ebr t\u00eb dyja nd\u00ebrfaqet mb\u00ebshtetet krijimi n\u00eb paket\u00eb i Target\/LUN.<\/p>\n<p><\/p>\n<p>Nj\u00eb v\u00ebrejtje e r\u00ebnd\u00ebsishme n\u00eb rastin e p\u00ebrdorimit t\u00eb nd\u00ebrfaqes iSCSI \u00ebsht\u00eb krijimi i disa target-eve p\u00ebr volumet menj\u00ebher\u00eb p\u00ebr t\u00eb rritur performanc\u00ebn, pasi radhitja n\u00eb target nuk mund t\u00eb ndryshohet dhe p\u00ebrfundimisht do t\u00eb jet\u00eb pika e ngusht\u00eb.<\/p>\n<p><\/p>\n<p><b><i><\/p>\n<h3>Konfigurimi i host-\u00ebve ESXi<\/h3>\n<p><\/i><\/b><\/p>\n<p><\/p>\n<p>Nga ana e host-\u00ebve ESXi, konfigurimi baz\u00eb kryhet sipas nj\u00eb skenari t\u00eb pritsh\u00ebm. Rendi i veprimeve p\u00ebr lidhjen iSCSI:<\/p>\n<p><\/p>\n<ol>\n<li>Shto Adapterin Software iSCSI (nuk k\u00ebrkohet, n\u00ebse ai tashm\u00eb \u00ebsht\u00eb shtuar, ose n\u00eb rastin e p\u00ebrdorimit t\u00eb Adapterit Hardware iSCSI);<\/li>\n<li>Krijimi i vSwitch-it, p\u00ebrmes t\u00eb cilit do t\u00eb kaloj\u00eb trafiku i iSCSI, dhe shtimi i uplink-vetor\u00ebve fizik\u00eb dhe VMkernel;<\/li>\n<li>Shtimi n\u00eb Dynamic Discovery i adresave t\u00eb array-t;<\/li>\n<li>Krijimi i Datastore<\/li>\n<\/ol>\n<p><\/p>\n<p><b>Disa v\u00ebrejtje t\u00eb r\u00ebnd\u00ebsishme:<\/b><\/p>\n<p><\/p>\n<blockquote>\n<ul>\n<li>N\u00eb p\u00ebrgjith\u00ebsi, sigurisht q\u00eb mund t\u00eb p\u00ebrdorni edhe vSwitch-in e ekzistuesh\u00ebm, por n\u00eb rastin e nj\u00eb vSwitch-i t\u00eb ve\u00e7ant\u00eb, menaxhimi i cil\u00ebsimeve t\u00eb hostit do t\u00eb jet\u00eb shum\u00eb m\u00eb i leht\u00eb.<\/li>\n<li>Duhet t\u00eb ndahen trafiku i Menaxhimit dhe iSCSI n\u00eb lidhje fizike dhe\/ose VLAN t\u00eb ve\u00e7anta p\u00ebr t\u00eb shmangur probleme me performanc\u00ebn.<\/li>\n<li>IP adresat e VMkernel dhe t\u00eb portave p\u00ebrkat\u00ebs t\u00eb All Flash array duhet t\u00eb jen\u00eb n\u00eb t\u00eb nj\u00ebjt\u00ebn n\u00ebndet\u00eb, p\u00ebrs\u00ebri p\u00ebr shkak t\u00eb \u00e7\u00ebshtjeve t\u00eb performanc\u00ebs.<\/li>\n<li>P\u00ebr t\u00eb siguruar disponueshm\u00ebrin\u00eb sipas rregullave t\u00eb VMware, vSwitch duhet t\u00eb ket\u00eb t\u00eb pakt\u00ebn dy uplink fizik\u00eb.<\/li>\n<li>N\u00ebse p\u00ebrdoren Jumbo Frames, \u00ebsht\u00eb e nevojshme t\u00eb ndryshoni MTU-n\u00eb si n\u00eb vSwitch, ashtu edhe n\u00eb VMkernel.<\/li>\n<li>Nuk do t\u00eb ishte e tep\u00ebrt t\u00eb kujtojm\u00eb se sipas rekomandimeve t\u00eb VMware p\u00ebr adaptator\u00ebt fizik\u00eb q\u00eb do t\u00eb p\u00ebrdoren p\u00ebr trafikun e iSCSI, duhet patjet\u00ebr t\u00eb b\u00ebhet konfigurimi i Teaming and Failover. N\u00eb ve\u00e7anti, secili VMkernel duhet t\u00eb funksionoj\u00eb vet\u00ebm p\u00ebrmes nj\u00eb uplink, uplink-u i dyt\u00eb duhet t\u00eb kaloj\u00eb n\u00eb m\u00ebnyr\u00ebn unused. P\u00ebr disponueshm\u00ebrin\u00eb \u00ebsht\u00eb e nevojshme t\u00eb shtoni dy VMkernel, secili prej t\u00eb cil\u00ebve do t\u00eb funksionoj\u00eb p\u00ebrmes uplink-ut t\u00eb vet.<\/li>\n<\/ul>\n<p>\n<\/p><\/blockquote>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/_h\/jb\/va\/_hjbvatnuhjwts4duy2epgb7bbi.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/b769fa87aa8552ed6dd775f9f9dcb1b5.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>VMkernel Adapter (vmk#)<br \/>\nPhysical Network Adapter (vmnic#)<\/p>\n<p>vmk1 (Storage01)<br \/>\nActive Adapters<br \/>\nvmnic2<br \/>\nUnused Adapters<br \/>\nvmnic3<\/p>\n<p>vmk2 (Storage02)<br \/>\nActive Adapters<br \/>\nvmnic3<br \/>\nUnused Adapters<br \/>\nvmnic2<\/p>\n<p>P\u00ebr t'u lidhur p\u00ebrmes Fibre Channel nuk nevojiten veprime paraprake. Mund t\u00eb krijoni menj\u00ebher\u00eb Datastore.<\/p>\n<p><\/p>\n<p>Pas krijimit t\u00eb Datastore-it, \u00ebsht\u00eb e nevojshme t\u00eb siguroheni q\u00eb po p\u00ebrdoret politika Round Robin p\u00ebr shtigjet n\u00eb Target\/LUN si m\u00eb e efektshme.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/zh\/zr\/t1\/zhzrt15baoc1qlp0w6ds-mys3hu.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/621474aa13123cd44518b263f222e6b5.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>Sipas parazgjedhjeve, VMware parashikon p\u00ebrdorimin e k\u00ebsaj politike sipas skem\u00ebs: 1000 k\u00ebrkesa p\u00ebrmes shtigjeve t\u00eb par\u00eb, 1000 k\u00ebrkesa t\u00eb tjera p\u00ebrmes t\u00eb dytit dhe k\u00ebshtu me radh\u00eb. Kjo nd\u00ebrveprim mes hostit dhe nj\u00eb grumbulli me dy kontrollues do t\u00eb jet\u00eb i pabalancuar. Prandaj, rekomandojm\u00eb t\u00eb vendosni parametrin Round Robin policy = 1 p\u00ebrmes Esxcli\/PowerCLI.<\/p>\n<p>\n<b class=\"spoiler_title\">Parametrat<\/b><\/p>\n<p>P\u00ebr Esxcli:<\/p>\n<p><\/p>\n<ul>\n<li>Shfaqni LUN-t\u00eb e disponueshme<\/li>\n<\/ul>\n<p><\/p>\n<p><b>esxcli storage nmp device list<\/b><\/p>\n<p><\/p>\n<ul>\n<li>Kopjoni Emrin e Dispositivit<\/li>\n<li>Ndryshoni Politiken Round Robin<\/li>\n<\/ul>\n<p><\/p>\n<p><b>esxcli storage nmp psp roundrobin deviceconfig set &#8212;type=iops &#8212;iops=1 &#8212;device=\u00abDevice_ID\u00bb<\/b><\/p>\n<p><\/p>\n<p>Shumica e aplikacioneve moderne \u00ebsht\u00eb projektuar p\u00ebr t\u00eb shk\u00ebmbyer paketa t\u00eb t\u00eb dh\u00ebnave me madh\u00ebsi t\u00eb madhe me q\u00ebllim optimizimin e p\u00ebrdorimit t\u00eb bandwidth-it dhe reduktimin e ngarkes\u00ebs n\u00eb procesorin qendror. Prandaj, ESXi p\u00ebr default transferon k\u00ebrkesat e hyrjes\/daljes n\u00eb pajisjen e ruajtjes n\u00eb pjes\u00eb deri n\u00eb 32767KB. Megjithat\u00eb, p\u00ebr disa skenar\u00eb, shk\u00ebmbimi i paketimeve m\u00eb t\u00eb vogla do t\u00eb jet\u00eb m\u00eb efikas. N\u00eb lidhje me arrays AccelStor, k\u00ebto jan\u00eb skenar\u00ebt e till\u00eb:<\/p>\n<p><\/p>\n<ul>\n<li>Makin\u00ebn virtuale e p\u00ebrdor UEFI n\u00eb vend t\u00eb BIOS-it Legacy<\/li>\n<li>P\u00ebrdoret vSphere Replication<\/li>\n<\/ul>\n<p><\/p>\n<p>P\u00ebr k\u00ebto skenar\u00eb, rekomandohet t\u00eb ndryshoni vler\u00ebn e parametrin Disk.DiskMaxIOSize n\u00eb 4096.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/1g\/et\/3g\/1get3g8odkem1onrpkwjdilbnsi.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/f7072bb572580d9bd6077afab8c272ba.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>P\u00ebr lidhjet iSCSI, rekomandohet t\u00eb ndryshoni parametrin Login Timeout n\u00eb 30 (p\u00ebr default 5) p\u00ebr t\u00eb rritur stabilitetin e lidhjes dhe t\u00eb \u00e7aktivizoni vones\u00ebn e konfirmimeve t\u00eb paketimeve t\u00eb d\u00ebrguara DelayedAck. T\u00eb dy opsionet jan\u00eb n\u00eb vSphere Client: Host \u2192 Configure \u2192 Storage \u2192 Storage Adapters \u2192 Advanced Options p\u00ebr adaptorin iSCSI.<\/p>\n<p><\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/1y\/5_\/c8\/1y5_c80zsijgqtngo-9vt2zbbo8.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/e9700594d0074b5439dbb397c081dd48.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/habrastorage.org\/webt\/bh\/yi\/tv\/bhyitvuujofnioaunwhzypx3fe0.png\"><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/c2dd6f3aaa6c0648763f66a94af2c251.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p><\/p>\n<p>Nj\u00eb \u00e7\u00ebshtje e r\u00ebnd\u00ebsishme \u00ebsht\u00eb numri i volumeve t\u00eb p\u00ebrdorur p\u00ebr datastore. E qart\u00eb q\u00eb p\u00ebr thjesht\u00ebsi menaxhimi, ka nj\u00eb d\u00ebshir\u00eb p\u00ebr t\u00eb krijuar nj\u00eb volum t\u00eb madh p\u00ebr t\u00eb gjith\u00eb kapacitetin e array-t. Megjithat\u00eb, prania e disa volumeve dhe, p\u00ebr pasoj\u00eb, e datastore-ve ka nj\u00eb ndikim pozitiv n\u00eb performanc\u00ebn e p\u00ebrgjithshme (m\u00eb shum\u00eb rreth radh\u00ebve m\u00eb posht\u00eb n\u00eb tekst). Prandaj, rekomandojm\u00eb krijimin e t\u00eb pakt\u00ebn dy volumeve.<\/p>\n<p><\/p>\n<p>Disa koh\u00eb m\u00eb par\u00eb, VMware k\u00ebshillonte kufizimin e numrit t\u00eb makinave virtuale n\u00eb nj\u00eb datastore, s\u00ebrish me q\u00ebllim p\u00ebr t\u00eb arritur performanc\u00ebn m\u00eb t\u00eb lart\u00eb t\u00eb mundshme. Megjithat\u00eb, tani, sidomos me p\u00ebrhapjen e VDI, kjo \u00e7\u00ebshtje nuk \u00ebsht\u00eb kaq problematike. Por kjo nuk e heq rregullin e vjet\u00ebr \u2014 shp\u00ebrndarjen e makinave virtuale q\u00eb k\u00ebrkojn\u00eb input-output t\u00eb intensifikuar n\u00eb datastore t\u00eb ndryshme. P\u00ebr t\u00eb p\u00ebrcaktuar numrin optimal t\u00eb makinave virtuale n\u00eb nj\u00eb volum, nuk ka mjet m\u00eb t\u00eb mir\u00eb se <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/zaprosit-demo\">testimin e ngarkes\u00ebs s\u00eb arrays All Flash AccelStor <\/a><\/noindex>n\u00eb kuad\u00ebr t\u00eb infrastruktur\u00ebs tuaj.<\/p>\n<p><\/p>\n<h3><i><b>Konfigurimi i makinave virtuale<\/b><\/i><\/h3>\n<p><\/p>\n<p>Nuk ka k\u00ebrkesa t\u00eb ve\u00e7anta p\u00ebr konfigurimin e makinave virtuale, p\u00ebr sa koh\u00eb ato jan\u00eb krejt normale:<\/p>\n<p><\/p>\n<ul>\n<li>P\u00ebrdorni versionin maksimal t\u00eb mundsh\u00ebm t\u00eb VM (kompatibiliteti)<\/li>\n<li>Keni kujdes n\u00eb caktimin e madh\u00ebsis\u00eb s\u00eb RAM-it kur vendosni virtual machines ngusht, p\u00ebr shembull, n\u00eb VDI, (sepse m\u00eb default krijohet nj\u00eb sked\u00eb k\u00ebmbimi t\u00eb ngjashme me madh\u00ebsin\u00eb e RAM-it, duke shpenzuar hap\u00ebsir\u00ebn e dobishme dhe duke ndikuar n\u00eb performanc\u00ebn p\u00ebrfundimtare)<\/li>\n<li>P\u00ebrdorni versionet m\u00eb t\u00eb fuqishme p\u00ebr IO t\u00eb adaptator\u00ebve: rrjetin e tipit VMXNET 3 dhe SCSI t\u00eb tipit PVSCSI<\/li>\n<li>P\u00ebrdorni tipin e diskut Thick Provision Eager Zeroed p\u00ebr performanc\u00ebn maksimale dhe Thin Provisioning p\u00ebr shfryt\u00ebzimin m\u00eb efikas t\u00eb hap\u00ebsir\u00ebs s\u00eb ruajtjes<\/li>\n<li>Sa m\u00eb shum\u00eb t\u00eb jet\u00eb e mundur, kufizoni pun\u00ebn e makinave q\u00eb nuk jan\u00eb t\u00eb kritikuara p\u00ebr input\/output me ndihm\u00ebn e Virtual Disk Limit<\/li>\n<li>Sigurisht, instaloni VMware Tools <\/li>\n<\/ul>\n<p><\/p>\n<h3><i><b>V\u00ebrejtje p\u00ebr radh\u00ebt<\/b><\/i><\/h3>\n<p><\/p>\n<p>Radh\u00eb (ose I\/Os t\u00eb jashtme) \u00ebsht\u00eb numri i k\u00ebrkesave t\u00eb hyrjes\/daljes (komandave SCSI) q\u00eb presin p\u00ebrpunim n\u00eb \u00e7do moment t\u00eb caktuar p\u00ebr nj\u00eb pajisje\/aplikacion t\u00eb caktuar. N\u00eb rast t\u00eb mbingarkes\u00ebs s\u00eb radh\u00ebs, jepet gabimi QFULL, i cili p\u00ebrfundimisht shpreh rritjen e parametrave t\u00eb latenc\u00ebs. Kur p\u00ebrdoren sisteme ruajtjeje me disqe (spindle), teorikisht, sa m\u00eb e lart\u00eb t\u00eb jet\u00eb radh\u00eb, aq m\u00eb e lart\u00eb \u00ebsht\u00eb rezultati i tyre. Megjithat\u00eb, nuk duhet tepruar, pasi \u00ebsht\u00eb e leht\u00eb t\u00eb p\u00ebrballesh me QFULL. N\u00eb rastin e sistemeve All Flash, nga nj\u00ebr\u00ebn an\u00eb, gjith\u00e7ka \u00ebsht\u00eb pak m\u00eb e thjesht\u00eb: pasi grumbulli ka vonesa shum\u00eb m\u00eb t\u00eb ul\u00ebta dhe p\u00ebr k\u00ebt\u00eb arsye shpesh nuk \u00ebsht\u00eb e nevojshme t\u00eb rregullohet ve\u00e7mas madh\u00ebsia e radh\u00ebve. Nga ana tjet\u00ebr, n\u00eb disa skenar\u00eb p\u00ebrdorimi (nj\u00eb devijim i fort\u00eb n\u00eb k\u00ebrkesat p\u00ebr IO p\u00ebr makina virtuale t\u00eb ve\u00e7anta, teste p\u00ebr performanc\u00ebn maksimale, etj.) \u00ebsht\u00eb e nevojshme, n\u00ebse jo t\u00eb ndryshosh parametrat e radh\u00ebs, t\u00eb pakt\u00ebn t\u00eb kuptosh \u00e7far\u00eb parametrash mund t\u00eb arrihet dhe, m\u00eb e r\u00ebnd\u00ebsishmja, me \u00e7far\u00eb m\u00ebnyrash.<\/p>\n<p><\/p>\n<p>N\u00eb grumbullin e plot\u00eb All Flash AccelStor nuk ka asnj\u00eb limit n\u00eb lidhje me volumin ose portet e hyrjes\/daljes. N\u00ebse \u00ebsht\u00eb e nevojshme, edhe nj\u00eb volum i vet\u00ebm mund t\u00eb marr\u00eb t\u00eb gjith\u00eb burimet e grumbullit. E vetmja kufizim n\u00eb radh\u00ebt \u00ebsht\u00eb p\u00ebr targetet iSCSI. Pik\u00ebrisht p\u00ebr k\u00ebt\u00eb arsye, ishin p\u00ebrmendur nevoja p\u00ebr t\u00eb krijuar disa (idealisht deri n\u00eb 8 cop\u00eb) targete p\u00ebr \u00e7do volum p\u00ebr t\u00eb tejkaluar k\u00ebt\u00eb limit. Po ashtu, le t\u00eb rip\u00ebrs\u00ebrisim q\u00eb grumbujt AccelStor jan\u00eb zgjidhje shum\u00eb t\u00eb performanc\u00ebs s\u00eb lart\u00eb. Prandaj, duhet t\u00eb angazhohen t\u00eb gjith\u00eb portet interfaci t\u00eb sistemit p\u00ebr t\u00eb arritur shpejt\u00ebsin\u00eb maksimale.<\/p>\n<p><\/p>\n<p>Nga ana e hostit ESXi, situata \u00ebsht\u00eb krejt ndryshe. Vet\u00eb hosti p\u00ebrdor praktikat e qasjes s\u00eb barabart\u00eb n\u00eb burime p\u00ebr t\u00eb gjith\u00eb pjes\u00ebmarr\u00ebsit. Prandaj, ekzistojn\u00eb radh\u00eb t\u00eb ndara IO p\u00ebr sistemin operativ t\u00eb mysafir\u00ebve dhe HBA. Radh\u00ebt p\u00ebr sistemin operativ t\u00eb mysafir\u00ebve kombinohen nga radh\u00ebt p\u00ebr adaptorin virtual SCSI dhe diskun virtual:<\/p>\n<p><\/p>\n<p><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/e6033427e6f554490c9a6460574b7f6e.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>Radh\u00ebt p\u00ebr HBA varen nga tipi\/p\u00ebrfaq\u00ebsuesi i caktuar:<\/p>\n<p><\/p>\n<p><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/a0b078e63bdf8f306a25bfecd1310cb0.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p>Performanca p\u00ebrfundimtare e makin\u00ebs virtuale do t\u00eb p\u00ebrcaktohet nga vlera m\u00eb e vog\u00ebl e kufirit t\u00eb radh\u00ebs (Queue Depth limit) mes komponenteve t\u00eb hostit. <\/p>\n<p><\/p>\n<p>Fal\u00eb k\u00ebtyre vlerave, mund t\u00eb vler\u00ebsojm\u00eb treguesit e performanc\u00ebs q\u00eb mund t\u00eb arrijm\u00eb n\u00eb konfigurime t\u00eb ndryshme. P\u00ebr shembull, ne duam t\u00eb dim\u00eb performanc\u00ebn teorike t\u00eb makineris\u00eb virtuale (pa lidhje me unitin) me latenc\u00eb 0.5ms. At\u00ebher\u00eb IOPS e saj = (1,000\/latenc\u00eb) * I\/O t\u00eb jashtme (Limiti i Gjat\u00ebsis\u00eb s\u00eb Radh\u00ebs)<\/p>\n<p>\n<b class=\"spoiler_title\">Shembuj<\/b><\/p>\n<p><b>Shembulli 1<\/b><\/p>\n<p><\/p>\n<ul>\n<li>Adaptori HBA FC Emulex<\/li>\n<li>Nj\u00eb VM n\u00eb datastore<\/li>\n<li>Adaptori VMware Paravirtual SCSI<\/li>\n<\/ul>\n<p><\/p>\n<p>K\u00ebtu, Limiti i Gjat\u00ebsis\u00eb s\u00eb Radh\u00ebs caktohet nga Emulex HBA. Prandaj, IOPS = (1000\/0.5)*32 = 64K<\/p>\n<p><\/p>\n<p><b>Shembulli 2<\/b><\/p>\n<p><\/p>\n<ul>\n<li>Adaptori VMware iSCSI Software<\/li>\n<li>Nj\u00eb VM n\u00eb datastore<\/li>\n<li>Adaptori VMware Paravirtual SCSI<\/li>\n<\/ul>\n<p><\/p>\n<p>K\u00ebtu, Limiti i Gjat\u00ebsis\u00eb s\u00eb Radh\u00ebs caktohet nga Paravirtual SCSI Adapter. Prandaj, IOPS = (1000\/0.5)*64 = 128K<\/p>\n<p><\/p>\n<p>Modelet kryesore t\u00eb grupeve All Flash AccelStor (p.sh., <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/product\/neosapphire-p710\">P710<\/a><\/noindex>) jan\u00eb n\u00eb gjendje t\u00eb ofrojn\u00eb performanc\u00eb 700K IOPS n\u00eb shkruarje me blok 4K. Me k\u00ebt\u00eb madh\u00ebsi bloku, \u00ebsht\u00eb e qart\u00eb se nj\u00eb makin\u00eb virtuale nuk mund ta ngarkoj\u00eb nj\u00eb grup t\u00eb till\u00eb. K\u00ebt\u00eb do ta k\u00ebrkoj\u00eb 11 (p\u00ebr shembull 1) ose 6 (p\u00ebr shembull 2) makina virtuale.<\/p>\n<p><\/p>\n<p>Si p\u00ebrfundim, me konfigurimin e duhur t\u00eb t\u00eb gjitha komponenteve t\u00eb p\u00ebrmendura t\u00eb qendr\u00ebs virtuale t\u00eb t\u00eb dh\u00ebnave, mund t\u00eb arrijm\u00eb rezultate t\u00eb mrekullueshme n\u00eb aspektin e performanc\u00ebs.<\/p>\n<p><\/p>\n<p><img decoding=\"async\" alt=\"Rekomandimet p\u00ebr konfigurimin e AFA AccelStor gjat\u00eb p\u00ebrdorimit me VMware vSphere\" src=\"\/wp-content\/uploads\/2019\/04\/eee93cccf16539410695c6f79d94deda.jpg\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<p><i>4K Rast\u00ebsor, 70% Lexo\/30% Shkruaj<\/i><\/p>\n<p><\/p>\n<p>N\u00eb t\u00eb v\u00ebrtet\u00eb, bota reale \u00ebsht\u00eb shum\u00eb m\u00eb e komplikuar p\u00ebr t'u p\u00ebrshkruar me nj\u00eb formul\u00eb t\u00eb thjesht\u00eb. N\u00eb nj\u00eb host gjithmon\u00eb ndodhen shum\u00eb makineri virtuale me konfiguracione dhe k\u00ebrkesa t\u00eb ndryshme p\u00ebr IO. Po ashtu, procesori i hostit merret me p\u00ebrpunimin e hyrjes\/daljes, fuqia e t\u00eb cilit nuk \u00ebsht\u00eb e pafundme. K\u00ebshtu, p\u00ebr t\u00eb shpalosur potencialin e plot\u00eb t\u00eb <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/product\/neosapphire-p710\">modelit P710<\/a><\/noindex> n\u00eb realitet do t\u00eb nevojiten t\u00eb pakt\u00ebn tre hoste. P\u00ebr m\u00eb tep\u00ebr, aplikacionet q\u00eb funksionojn\u00eb brenda makinave virtuale b\u00ebjn\u00eb ndryshime t\u00eb veta. Prandaj, p\u00ebr nj\u00eb dimensionim t\u00eb sakt\u00eb, ne rekomandojm\u00eb <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/page\/zaprosit-demo\">t\u00eb p\u00ebrdorni verifikimin n\u00eb terren t\u00eb modeleve testuese<\/a><\/noindex> t\u00eb gjith\u00eb Flash array <noindex><a rel=\"nofollow\" href=\"http:\/\/accelstor.ru\/\">AccelStor<\/a><\/noindex> brenda infrastruktur\u00ebs s\u00eb klientit p\u00ebr detyrat aktuale reale.<\/p>\n<p>Burimi: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/accelstor\/blog\/447390\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0412 \u0440\u0430\u043c\u043a\u0430\u0445 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0445\u043e\u0442\u0435\u043b\u043e\u0441\u044c \u0431\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u0442\u044c \u043e\u0431 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044f\u0445 \u0440\u0430\u0431\u043e\u0442\u044b All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u043e\u0432 AccelStor \u0441 \u043e\u0434\u043d\u043e\u0439 \u0438\u0437 \u043f\u043e\u043f\u0443\u043b\u044f\u0440\u043d\u0435\u0439\u0448\u0438\u0445 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u2013 VMware vSphere. \u0412 \u0447\u0430\u0441\u0442\u043d\u043e\u0441\u0442\u0438, \u0430\u043a\u0446\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043d\u0430 \u0442\u0435\u0445 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u0430\u0445, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u044d\u0444\u0444\u0435\u043a\u0442 \u043e\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0442\u0430\u043a\u043e\u0433\u043e \u043c\u043e\u0449\u043d\u043e\u0433\u043e \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u0430, \u043a\u0430\u043a All Flash. All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u044b AccelStor NeoSapphire\u2122 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0442 \u0441\u043e\u0431\u043e\u0439 \u043e\u0434\u043d\u043e \u0438\u043b\u0438 \u0434\u0432\u0443\u0445 \u043d\u043e\u0434\u043e\u0432\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":23196,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-31230","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.0.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0412 \u0440\u0430\u043c\u043a\u0430\u0445 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0445\u043e\u0442\u0435\u043b\u043e\u0441\u044c \u0431\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u0442\u044c \u043e\u0431 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044f\u0445 \u0440\u0430\u0431\u043e\u0442\u044b All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u043e\u0432 AccelStor \u0441 \u043e\u0434\u043d\u043e\u0439 \u0438\u0437 \u043f\u043e\u043f\u0443\u043b\u044f\u0440\u043d\u0435\u0439\u0448\u0438\u0445 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u2013 VMware vSphere. \u0412 \u0447\u0430\u0441\u0442\u043d\u043e\u0441\u0442\u0438, \u0430\u043a\u0446\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043d\u0430 \u0442\u0435\u0445 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u0430\u0445, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u044d\u0444\u0444\u0435\u043a\u0442 \u043e\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0442\u0430\u043a\u043e\u0433\u043e \u043c\u043e\u0449\u043d\u043e\u0433\u043e \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u0430, \u043a\u0430\u043a All Flash. All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u044b AccelStor NeoSapphire\u2122 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0442 \u0441\u043e\u0431\u043e\u0439 \u043e\u0434\u043d\u043e \u0438\u043b\u0438 \u0434\u0432\u0443\u0445 \u043d\u043e\u0434\u043e\u0432\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.0.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"sq_AL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0438 \u043f\u043e \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0435 AFA AccelStor \u043f\u0440\u0438 \u0440\u0430\u0431\u043e\u0442\u0435 \u0441 VMware vSphere | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0412 \u0440\u0430\u043c\u043a\u0430\u0445 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0445\u043e\u0442\u0435\u043b\u043e\u0441\u044c \u0431\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u0442\u044c \u043e\u0431 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044f\u0445 \u0440\u0430\u0431\u043e\u0442\u044b All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u043e\u0432 AccelStor \u0441 \u043e\u0434\u043d\u043e\u0439 \u0438\u0437 \u043f\u043e\u043f\u0443\u043b\u044f\u0440\u043d\u0435\u0439\u0448\u0438\u0445 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u2013 VMware vSphere. \u0412 \u0447\u0430\u0441\u0442\u043d\u043e\u0441\u0442\u0438, \u0430\u043a\u0446\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043d\u0430 \u0442\u0435\u0445 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u0430\u0445, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u044d\u0444\u0444\u0435\u043a\u0442 \u043e\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0442\u0430\u043a\u043e\u0433\u043e \u043c\u043e\u0449\u043d\u043e\u0433\u043e \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u0430, \u043a\u0430\u043a All Flash. All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u044b AccelStor NeoSapphire\u2122 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0442 \u0441\u043e\u0431\u043e\u0439 \u043e\u0434\u043d\u043e \u0438\u043b\u0438 \u0434\u0432\u0443\u0445 \u043d\u043e\u0434\u043e\u0432\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T18:40:10+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T18:40:10+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47K\u00ebshilla p\u00ebr konfigurimin e AFA AccelStor p\u00ebr pun\u00ebn me VMware vSphere | ProHoster","description":"N\u00eb k\u00ebt\u00eb artikull, do t\u00eb diskutojm\u00eb karakteristikat e funksionimit t\u00eb grupeve All Flash AccelStor me nj\u00eb nga platform\u00ebn m\u00eb t\u00eb njohura t\u00eb virtualizimit \u2013 VMware vSphere. N\u00eb ve\u00e7anti, do t\u00eb theksojm\u00eb ato parameter\u00eb q\u00eb do t\u00eb ndihmojn\u00eb n\u00eb maksimizimin e efektit t\u00eb p\u00ebrdorimit t\u00eb nj\u00eb mjeti kaq t\u00eb fuqish\u00ebm si\u00e7 \u00ebsht\u00eb All Flash. Grupe t\u00eb gjall\u00eb All Flash AccelStor NeoSapphire\u2122 jan\u00eb pajisje me nj\u00eb ose dy nodo.","canonical_url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sq_AL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0438 \u043f\u043e \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0435 AFA AccelStor \u043f\u0440\u0438 \u0440\u0430\u0431\u043e\u0442\u0435 \u0441 VMware vSphere | ProHoster","og:description":"\u0412 \u0440\u0430\u043c\u043a\u0430\u0445 \u0434\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0438 \u0445\u043e\u0442\u0435\u043b\u043e\u0441\u044c \u0431\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u0442\u044c \u043e\u0431 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044f\u0445 \u0440\u0430\u0431\u043e\u0442\u044b All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u043e\u0432 AccelStor \u0441 \u043e\u0434\u043d\u043e\u0439 \u0438\u0437 \u043f\u043e\u043f\u0443\u043b\u044f\u0440\u043d\u0435\u0439\u0448\u0438\u0445 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u2013 VMware vSphere. \u0412 \u0447\u0430\u0441\u0442\u043d\u043e\u0441\u0442\u0438, \u0430\u043a\u0446\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043d\u0430 \u0442\u0435\u0445 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u0430\u0445, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u044d\u0444\u0444\u0435\u043a\u0442 \u043e\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0442\u0430\u043a\u043e\u0433\u043e \u043c\u043e\u0449\u043d\u043e\u0433\u043e \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u0430, \u043a\u0430\u043a All Flash. All Flash \u043c\u0430\u0441\u0441\u0438\u0432\u044b AccelStor NeoSapphire\u2122 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0442 \u0441\u043e\u0431\u043e\u0439 \u043e\u0434\u043d\u043e \u0438\u043b\u0438 \u0434\u0432\u0443\u0445 \u043d\u043e\u0434\u043e\u0432\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430","og:url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/rekomendatsii-po-nastrojke-afa-accelstor-pri-rabote-s-vmware-vsphere","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T18:40:10+00:00","article:modified_time":"2019-10-31T18:40:10+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"31230","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-21 05:09:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 03:20:31","updated":"2026-01-21 05:09:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/31230","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/comments?post=31230"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/31230\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media\/23196"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media?parent=31230"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/categories?post=31230"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/tags?post=31230"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}