{"id":38294,"date":"2019-10-31T22:22:48","date_gmt":"2019-10-31T19:22:48","guid":{"rendered":"https:\/\/prohoster.info\/blog\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\/"},"modified":"2019-10-31T22:22:48","modified_gmt":"2019-10-31T19:22:48","slug":"anboksing-stoechnogo-servera-cisco-ucs-c240-m5","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","title":{"rendered":"Anboksimi i serverit n\u00eb raft Cisco UCS C240 M5","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Sot \u00ebsht\u00eb nj\u00eb server rack i ri Cisco UCS C240 i gjenerat\u00ebs s\u00eb pest\u00eb. <\/p>\n<p>\u00c7far\u00eb e b\u00ebn k\u00ebt\u00eb server Cisco interesante p\u00ebr shqyrtim, duke marr\u00eb parasysh se po flasim p\u00ebr gjenerat\u00ebn e tij t\u00eb pest\u00eb? <\/p>\n<p><img decoding=\"async\" alt=\"Anboksimi i serverit n\u00eb raft Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/419d39ba895739a71b337f03445a9c32.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nS\u00eb pari, server\u00ebt Cisco tani mb\u00ebshtesin brezin e fundit t\u00eb procesor\u00ebve Intel Scalable t\u00eb gjenerat\u00ebs s\u00eb dyt\u00eb. S\u00eb dyti, tani \u00ebsht\u00eb e mundur t\u00eb instalohen modulat Optane Memory p\u00ebr t\u00eb p\u00ebrdorur shum\u00eb drive NVMe. <br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nShfaqen pyetje t\u00eb arsyeshme: a e b\u00ebjn\u00eb server\u00ebt e tjer\u00eb k\u00ebt\u00eb? \u00c7far\u00eb \u00ebsht\u00eb e ve\u00e7ant\u00eb, pasi \u00ebsht\u00eb thjesht nj\u00eb server x86? Le t\u00eb shpjegojm\u00eb gjith\u00e7ka n\u00eb radh\u00eb. <\/p>\n<p>P\u00ebrve\u00e7 detyrave t\u00eb nj\u00eb serveri t\u00eb ve\u00e7ant\u00eb, Cisco C240 M5 mund t\u00eb b\u00ebhet pjes\u00eb e arkitektur\u00ebs Cisco UCS. K\u00ebtu flasim p\u00ebr lidhjen me FI dhe menaxhimin e plot\u00eb t\u00eb server\u00ebve p\u00ebrmes UCS Manager, duke p\u00ebrfshir\u00eb Auto Deploy. <\/p>\n<p>Pra, para nesh \u00ebsht\u00eb nj\u00eb server \u201charduer\u201d Cisco, gjenerata e tij e pest\u00eb, m\u00eb shum\u00eb se 10 vjet n\u00eb treg. <br \/>\nTani do t\u00eb kthehemi n\u00eb baza, duke kujtuar se nga \u00e7far\u00eb komponent\u00ebsh ka nj\u00eb server, dhe \u00e7far\u00eb e b\u00ebn Cisco C240 M5 jo vet\u00ebm modern, por v\u00ebrtet t\u00eb avancuar. <\/p>\n<p>Le t\u00eb shohim se \u00e7far\u00eb p\u00ebrfshihet n\u00eb kutin\u00eb e d\u00ebrges\u00ebs. <\/p>\n<p><b>P\u00ebrmbajtja e kutis\u00eb<\/b>: server, KVM Dongle, dokumente, nj\u00eb disk, 2 kabllo energjie, paket\u00eb montimi. <\/p>\n<p><img decoding=\"async\" alt=\"Anboksimi i serverit n\u00eb raft Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/4e6b39ebc4a78f8b37b29ea2d76da14e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nE heqim kapakun. Shtypim, l\u00ebvizim dhe gjith\u00e7ka \u00ebsht\u00eb gati. Asnj\u00eb screwdriver dhe asnj\u00eb vid\u00eb q\u00eb humbet. <br \/>\nT\u00eb gjith\u00eb element\u00ebt q\u00eb mb\u00ebshtesin z\u00ebvend\u00ebsimin e nxeht\u00eb e kan\u00eb nj\u00eb etiket\u00eb t\u00eb gjelb\u00ebr. P.sh., \u00ebsht\u00eb leht\u00ebsisht e mundur t\u00eb z\u00ebvend\u00ebsohen ventilator\u00ebt pa ndezur gjith\u00eb serverin. <\/p>\n<p><img decoding=\"async\" alt=\"Anboksimi i serverit n\u00eb raft Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/cb2fcaf627f96dd947421f65e80c2638.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nPo ashtu shohim radiator\u00eb masiv\u00eb, n\u00ebn t\u00eb cil\u00ebt fshihen procesor\u00ebt e rinj Intel Scal 2 Gen. V\u00ebreni se kjo \u00ebsht\u00eb deri n\u00eb 56 b\u00ebrthama n\u00eb nj\u00eb server 2U pa asnj\u00eb problem p\u00ebr ftohjen. Plus, mb\u00ebshtetet m\u00eb shum\u00eb memorie, deri n\u00eb 1TB p\u00ebr procesor. Frekuenca e mb\u00ebshtetur e memories gjithashtu \u00ebsht\u00eb rritur deri n\u00eb 2933 MHz. <\/p>\n<p>Af\u00ebr CPU shohim 24 slot p\u00ebr memorien e operativ\u00ebs \u2014 mund t\u00eb p\u00ebrdoren modula deri n\u00eb 128 GB ose memorie Intel Optane deri n\u00eb 512 GB p\u00ebr slot.<\/p>\n<p><img decoding=\"async\" alt=\"Anboksimi i serverit n\u00eb raft Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/147f87e31e346dbb0f360c92dccde512.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIntel Optane na ofron shpejt\u00ebsi t\u00eb \u00e7mendura p\u00ebr p\u00ebrpunimin. P.sh., mund t\u00eb p\u00ebrdoret si nj\u00eb SSD lokal super t\u00eb shpejt\u00eb.<\/p>\n<p>Sot gjithnj\u00eb e m\u00eb shum\u00eb k\u00ebrkesa nga klient\u00ebt fillojn\u00eb me fjal\u00ebt: \u201cDua m\u00eb shum\u00eb disqe, m\u00eb shum\u00eb drive NVMe n\u00eb nj\u00eb sistem.\u201d <\/p>\n<p>N\u00eb an\u00ebn e p\u00ebrparme ne shohim 8 slot p\u00ebr disqe 2.5 in\u00e7. Po ashtu, \u00ebsht\u00eb n\u00eb dispozicion p\u00ebr porosi nj\u00eb variant i platform\u00ebs me 24 slot standarde nga paneli i p\u00ebrparm\u00eb.<\/p>\n<p><img decoding=\"async\" alt=\"Anboksimi i serverit n\u00eb raft Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/ddeca4947e941f1dadfe2a691b8729d8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nVar\u00ebsisht nga modifikimi, n\u00eb slotet e para mund t\u00eb instaloni deri n\u00eb 8 disqe NMVe n\u00eb formatin U.2. <\/p>\n<p>Platforma C240 \u00ebsht\u00eb shum\u00eb e popullarizuar nd\u00ebr klient\u00ebt q\u00eb punojn\u00eb me t\u00eb dh\u00ebna t\u00eb m\u00ebdha. K\u00ebrkesa e tyre kryesore \u00ebsht\u00eb mund\u00ebsia p\u00ebr t\u00eb pasur disqe p\u00ebr ngarkim lokal dhe preferohet q\u00eb t\u00eb jen\u00eb hot pluggable.<\/p>\n<p>P\u00ebrgjigjja ndaj k\u00ebsaj k\u00ebrkes\u00eb \u00ebsht\u00eb zgjidhja e Cisco-s n\u00eb C240 M5 p\u00ebr t\u00eb shtuar dy slot p\u00ebr disqe me mb\u00ebshtetje p\u00ebr nd\u00ebrrim t\u00eb nxeht\u00eb n\u00eb pjes\u00ebn e pasme t\u00eb serverit.<\/p>\n<p>Ato jan\u00eb vendosur m\u00eb t\u00eb djathtas nga slotet e zgjerimit deri tek blloqet e energjis\u00eb. Disqet mund t\u00eb jen\u00eb t\u00eb \u00e7do lloji: SAS, SATA, SSD, NVMe.<\/p>\n<p><img decoding=\"async\" alt=\"Anboksimi i serverit n\u00eb raft Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/33ef5ba06667b6e130ce724bd27cf857.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nPran\u00eb shohim blloqet e energjis\u00eb me 1600W. Ato gjithashtu jan\u00eb Hot Pluggable dhe kan\u00eb etiketat e gjelbra.<\/p>\n<p><img decoding=\"async\" alt=\"Anboksimi i serverit n\u00eb raft Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/46ab4548bc3d84d497f772f7c8eaa633.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nP\u00ebr t\u00eb punuar me sistemin e disqeve, n\u00eb slotin e dedikuar mund t\u00eb instaloni nj\u00eb kontrollues RAID nga LSI me 2 GB cache, ose nj\u00eb kart\u00eb HBA p\u00ebr kalim t\u00eb drejtp\u00ebrdrejt\u00eb.<\/p>\n<p>P\u00ebr shembull, nj\u00eb qasje e till\u00eb p\u00ebrdoret n\u00eb nd\u00ebrtimin e zgjidhjes hiper-konvergjente Cisco HyperFlex.<\/p>\n<p>Ka nj\u00eb tjet\u00ebr lloj klient\u00ebsh q\u00eb nuk kan\u00eb nevoj\u00eb p\u00ebr disqe fare. Ata nuk duan t\u00eb instalojn\u00eb nj\u00eb kontrollues RAID t\u00eb plot\u00eb p\u00ebr hipervizorin, por u p\u00eblqen kaseta 2U p\u00ebr leht\u00ebsin\u00eb n\u00eb sh\u00ebrbim.<br \/>\nP\u00ebr ta, Cisco gjithashtu ka nj\u00eb zgjidhje.<\/p>\n<p>Po prezantoj modulin FlexFlash:<br \/>\nDy karta SD, deri n\u00eb 128 GB, me mb\u00ebshtetje p\u00ebr pasqyrim, p\u00ebr instalimin e hipervizorit, p\u00ebr shembull, VMware ESXi. Ky variant ne n\u00eb ITGLOBAL.COM e p\u00ebrdorim p\u00ebr nd\u00ebrtimin e platformave tona n\u00eb t\u00eb gjith\u00eb bot\u00ebn. <\/p>\n<p><img decoding=\"async\" alt=\"Anboksimi i serverit n\u00eb raft Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/d265c93e1e60428c69132b3cddb3a790.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nP\u00ebr ata klient\u00eb q\u00eb k\u00ebrkojn\u00eb m\u00eb shum\u00eb hap\u00ebsir\u00eb p\u00ebr ngarkimin e OS, ka nj\u00eb variant moduli p\u00ebr dy disqe SSD 'SATA' n\u00eb formatin M.2, me kapacitet 240 ose 960 GB secili. N\u00eb m\u00ebnyr\u00eb t\u00eb paracaktuar, ky \u00ebsht\u00eb nj\u00eb RAID software. <\/p>\n<p>P\u00ebr disqet e 240 GB ekziston mund\u00ebsia e p\u00ebrdorimit t\u00eb Cisco Boot optimized M.2 Raid controller \u2013 nj\u00eb kontrollues RAID i ve\u00e7ant\u00eb p\u00ebr k\u00ebto dy disqe SSD.<\/p>\n<p>T\u00eb gjitha k\u00ebto mb\u00ebshteten nga t\u00eb gjitha OS: dhe VMware dhe Windows, dhe nga sistemet e ndryshme Linux.<br \/>\nNumri i slot-eve PCI \u00ebsht\u00eb 6, q\u00eb \u00ebsht\u00eb karakteristik\u00eb e platformave 2U. <\/p>\n<p><img decoding=\"async\" alt=\"Anboksimi i serverit n\u00eb raft Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/67f57214e9f99cbad0add05865ed83f8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nBrenda ka mjaft hap\u00ebsir\u00eb. N\u00eb server\u00eb leht\u00eb mund t\u00eb instaloni dy p\u00ebrforcues grafike t\u00eb plot\u00eb nga NVidia, p\u00ebr shembull, TESLA M10 n\u00eb projekte implementimi <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/sq\/vps\/abuzoustojchivye-vps\/\"   title=\"e skripteve virtuale\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"1009\">e skripteve virtuale<\/a> ose versionin e fundit V100 me 32GB p\u00ebr detyra t\u00eb intelligjenc\u00ebs artificiale. K\u00ebt\u00eb ne e p\u00ebrdorim n\u00eb unboxing-un e ardhsh\u00ebm.<\/p>\n<p>Me portat \u00ebsht\u00eb k\u00ebshtu: <\/p>\n<ul>\n<li>Porti konsol\u00ebs;<\/li>\n<li>Porti i dedikuar 1 gigabit p\u00ebr menaxhim;<\/li>\n<li>Dy porte usb 3.0;<\/li>\n<li>Kabllil e integruar dy-portash Intel x550 10Gb BASE-T;<\/li>\n<li>Karta mLOM opsionale, Cisco Vic 1387 dy-portadaptor 40 Gb.<\/li>\n<\/ul>\n<p>\nN\u00eb slotin mLOM mund t\u00eb instalohet vet\u00ebm kartat Cisco VIC, t\u00eb cilat jan\u00eb efikase si p\u00ebr transferimin e trafikut LAN ashtu edhe SAN. P\u00ebrdorimi i serverit si pjes\u00eb e fabrik\u00ebs Cisco UCS, ky qasje lejon organizimin e lidhjes me rrjetet LAN dhe SAN n\u00eb m\u00ebnyr\u00eb t\u00eb nj\u00ebjt\u00eb pa pasur nevoj\u00eb p\u00ebr p\u00ebrdorimin e nj\u00eb adaptori fc t\u00eb ve\u00e7ant\u00eb. <\/p>\n<p>Le t\u00eb instalojm\u00eb videokart\u00ebn Nvidia V100. Heqim riserin e dyt\u00eb, heqim mbulimin, fusim kart\u00ebn n\u00eb slotin PCI, mbyllim plastik\u00ebn dhe m\u00eb pas mbulimin. Lidhim energjin\u00eb shtes\u00eb. S\u00eb pari n\u00eb kart\u00eb, pastaj n\u00eb riser. Rivendosim riserin n\u00eb vend. N\u00eb p\u00ebrgjith\u00ebsi, gjith\u00e7ka ndodh pa p\u00ebrdorimin e drejtorive dhe \u00e7eki\u00e7\u00ebve. Shpejt dhe sakt\u00eb.<\/p>\n<p>N\u00eb nj\u00eb nga materialet e ardhshme do ta tregojm\u00eb instalimin e tij fillestar. <\/p>\n<p>Ne gjithashtu jemi t\u00eb gatsh\u00ebm t\u00eb p\u00ebrgjigjemi p\u00ebr t\u00eb gjitha pyetjet <noindex><a rel=\"nofollow\" href=\"https:\/\/itglobal.com\/ru-ru\/solutions\/tech-partners\/cisco\/servers-unified-computing-system-ucs\/\">k\u00ebtu<\/a><\/noindex> ose n\u00eb komentet.<br \/>\n<br \/>Burimi: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/itglobalcom\/blog\/467981\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435? \u0412\u043e-\u043f\u0435\u0440\u0432\u044b\u0445, \u0441\u0435\u0440\u0432\u0435\u0440\u044b Cisco \u0442\u0435\u043f\u0435\u0440\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u0432 Intel Scalable \u0432\u0442\u043e\u0440\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0412\u043e-\u0432\u0442\u043e\u0440\u044b\u0445, \u0442\u0435\u043f\u0435\u0440\u044c \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043c\u043e\u0434\u0443\u043b\u0438 Optane Memory \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u0430 NVMe-\u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":28746,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-38294","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"sq_AL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Unboxing i serverit rack Cisco UCS C240 M5 | ProHoster","description":"Sot kemi n\u00eb tavolin\u00eb serverin e ri rack Cisco UCS C240 t\u00eb gjenerat\u00ebs s\u00eb pest\u00eb. \u00c7far\u00eb e b\u00ebn t\u00eb interesant p\u00ebr unboxing ky server Cisco, duke marr\u00eb parasysh se kemi p\u00ebrpara gjenerat\u00ebn e tij t\u00eb pest\u00eb?","canonical_url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sq_AL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster","og:description":"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?","og:url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:22:48+00:00","article:modified_time":"2019-10-31T19:22:48+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"38294","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-02-09 13:06:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 01:12:21","updated":"2026-02-09 13:06:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/38294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/comments?post=38294"}],"version-history":[{"count":1,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/38294\/revisions"}],"predecessor-version":[{"id":158206,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/38294\/revisions\/158206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media\/28746"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media?parent=38294"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/categories?post=38294"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/tags?post=38294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}