{"id":53854,"date":"2019-12-12T00:00:00","date_gmt":"2019-12-11T21:00:00","guid":{"rendered":"https:\/\/prohoster.info\/blog\/blog_prohoster\/vvedenie-v-ssd-chast-2-interfejsnaya"},"modified":"2020-02-18T14:01:47","modified_gmt":"2020-02-18T11:01:47","slug":"vvedenie-v-ssd-chast-2-interfejsnaya","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/vvedenie-v-ssd-chast-2-interfejsnaya","title":{"rendered":"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/37fa13397c0b8ea7af2be17b51c7ed83.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nN\u00eb <noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/selectel\/blog\/475304\/\">pjes\u00ebn e kaluar<\/a><\/noindex> N\u00eb ciklin \"Hyrje n\u00eb SSD\", ne treguam p\u00ebr historian e shfaqjes s\u00eb disqeve. Pjesa e dyt\u00eb do t\u00eb flas\u00eb p\u00ebr nd\u00ebrfaqet e bashk\u00ebpunimit me ruajt\u00ebsit.<\/p>\n<p>Komunikimi midis procesorit dhe pajisjeve periferike ndodh sipas marr\u00ebveshjeve t\u00eb paracaktuara, t\u00eb quajtura nd\u00ebrfaqe. K\u00ebto marr\u00ebveshje rregullojn\u00eb nivelin fizik dhe programor t\u00eb bashk\u00ebpunimit.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<blockquote><p><b>Nd\u00ebrfaqja \u00ebsht\u00eb nj\u00eb grumbull mjetesh, metodash dhe rregullash p\u00ebr bashk\u00ebpunimin midis element\u00ebve t\u00eb sistemit.<\/b><\/p><\/blockquote>\n<p>\nRealizimi fizik i nd\u00ebrfaqes ndikon n\u00eb parametrat e m\u00ebposht\u00ebm:<\/p>\n<ul>\n<li>kapacitetin e kanaleve t\u00eb komunikimit;<\/li>\n<li>numrin maksimal t\u00eb pajisjeve t\u00eb lidhura nj\u00ebkoh\u00ebsisht;<\/li>\n<li>numrin e gabimeve q\u00eb ndodhin.<\/li>\n<\/ul>\n<p>\nNd\u00ebrfaqet e disqeve jan\u00eb t\u00eb nd\u00ebrtuara mbi <b>porte hyrje-dalje<\/b>, q\u00eb \u00ebsht\u00eb n\u00eb kund\u00ebrshtim me hyrjen-daljen p\u00ebrmes memories dhe nuk z\u00eb hap\u00ebsir\u00eb n\u00eb hap\u00ebsir\u00ebn adresore t\u00eb procesorit.<\/p>\n<h2>Portet paralel dhe seriale<\/h2>\n<p>\nSipas m\u00ebnyr\u00ebs s\u00eb shk\u00ebmbimit t\u00eb t\u00eb dh\u00ebnave, portet hyrje-dalje ndahen n\u00eb dy tipe:<\/p>\n<ul>\n<li>paralel;<\/li>\n<li>serial.<\/li>\n<\/ul>\n<p>\nSi e tregon emri, porta paralele d\u00ebrgon nj\u00eb fjal\u00eb makinerie q\u00eb p\u00ebrb\u00ebhet nga disa bit\u00eb nj\u00ebher\u00ebsh. Porta paralele \u00ebsht\u00eb m\u00ebnyra m\u00eb e thjesht\u00eb p\u00ebr t\u00eb shk\u00ebmbyer t\u00eb dh\u00ebna, pasi nuk k\u00ebrkon zgjidhje t\u00eb komplikuara p\u00ebr skem\u00ebn elektronike. N\u00eb rastin m\u00eb t\u00eb thjesht\u00eb, \u00e7do bit i fjal\u00ebs makinerie d\u00ebrgohet p\u00ebrmes linj\u00ebs s\u00eb tij sinjale, dhe p\u00ebr informacionin e kthyer p\u00ebrdoren dy linja sinjalizimi sh\u00ebrbimi. <b>T\u00eb dh\u00ebnat jan\u00eb gati<\/b> dhe <b>T\u00eb dh\u00ebnat jan\u00eb pranuar<\/b>.<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"http:\/\/www.cabledepot.com\/05DTSERPAR.html\"><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/7521e01508ceb9a7ab6c346fd55edb0e.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nPortat paralele, n\u00eb pamje t\u00eb par\u00eb, shkall\u00ebzohen shum\u00eb mir\u00eb: m\u00eb shum\u00eb linja sinjali - m\u00eb shum\u00eb bit\u00eb d\u00ebrgohen nj\u00ebher\u00ebsh dhe, p\u00ebr pasoj\u00eb, kapaciteti i transmetimit \u00ebsht\u00eb m\u00eb i lart\u00eb. Megjithat\u00eb, p\u00ebr shkak t\u00eb rritjes s\u00eb numrit t\u00eb linjave sinjalizuese, ndodhin nd\u00ebrveprime nd\u00ebrmjet tyre q\u00eb shkaktojn\u00eb deformim t\u00eb mesazheve t\u00eb d\u00ebrguara.<\/p>\n<p>Portet sekondare jan\u00eb t\u00eb kund\u00ebrt me ata paralel. D\u00ebrgimi i t\u00eb dh\u00ebnave ndodh nj\u00eb bit n\u00eb nj\u00eb koh\u00eb, gj\u00eb q\u00eb redukton numrin e p\u00ebrgjithsh\u00ebm t\u00eb linjave t\u00eb sinjalit, por e komplikon kontrolluesin e hyrjes dhe daljes. Kontrolluesi i transmetuesit merr nj\u00eb fjal\u00eb makine n\u00eb nj\u00eb koh\u00eb dhe duhet t\u00eb d\u00ebrgoj\u00eb nj\u00eb bit, nd\u00ebrsa kontrolluesi i marr\u00ebsit n\u00eb an\u00ebn tjet\u00ebr duhet t\u00eb pranoj\u00eb bit\u00ebt dhe t'i ruaj\u00eb n\u00eb t\u00eb nj\u00ebjt\u00ebn rend.<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"http:\/\/www.cabledepot.com\/05DTSERPAR.html\"><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/1a264c6efc7d854fbf4513aec347f954.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nNumri i vog\u00ebl i linjave t\u00eb sinjalit lejon t\u00eb rritet pa nd\u00ebrprerje frekuenca e d\u00ebrgimit t\u00eb mesazhit.<\/p>\n<h2>SCSI<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/922b430a5fda8ae5e46db82db9573719.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nSmall Computer Systems Interface (SCSI) u shfaq n\u00eb vitin 1978 dhe u zhvillua fillimisht p\u00ebr t\u00eb lidhur pajisje t\u00eb profilit t\u00eb ndrysh\u00ebm n\u00eb nj\u00eb sistem t\u00eb vet\u00ebm. Specifikimi SCSI-1 parashikonte lidhjen e deri n\u00eb 8 pajisjeve (p\u00ebrfshir\u00eb kontrolluesin), t\u00eb tilla si:<\/p>\n<ul>\n<li>skaner\u00eb;<\/li>\n<li>disqe kaset\u00eb (streamers);<\/li>\n<li>drive-opti;<\/li>\n<li>disk\u00eb dhe pajisje t\u00eb tjera.<\/li>\n<\/ul>\n<p><\/p>\n<blockquote><p><b>N\u00eb fillim, SCSI kishte emrin Shugart Associates System Interface (SASI), por komiteti standardizues nuk e miratoi emrin n\u00eb nder t\u00eb kompanis\u00eb dhe pas nj\u00eb dite brainstorming-u doli emri Small Computer Systems Interface (SCSI). \"Babai\" i SCSI, Larry Boucher, n\u00ebnkuptoi se shkronjat do t\u00eb shqiptoheshin si \"sexy\", por <noindex><a rel=\"nofollow\" href=\"http:\/\/www.endl.com\/ida.htm\">Dal Allan<\/a><\/noindex> e lexoi \"s\u0441uzzy\" (\"skazi\"). M\u00eb pas, shqipti \"skazi\" u ngjit fort me k\u00ebt\u00eb standard.<\/b><\/p><\/blockquote>\n<p>\nN\u00eb terminologjin\u00eb SCSI, pajisjet e lidhura ndahen n\u00eb dy tipe:<\/p>\n<ul>\n<li>inisiator\u00ebt;<\/li>\n<li>pajisjet q\u00ebllimore.<\/li>\n<\/ul>\n<p>\nInisiatori d\u00ebrgon nj\u00eb urdh\u00ebr te pajisja q\u00ebllim, e cila pastaj i kthen p\u00ebrgjigje inisiatorit. Inisiator\u00ebt dhe pajisjet q\u00ebllimore jan\u00eb t\u00eb lidhura n\u00eb nj\u00eb autobus t\u00eb p\u00ebrbashk\u00ebt SCSI, me nj\u00eb kapacitet kalimi prej 5 MB\/s sipas standardit SCSI-1.<\/p>\n<p>Topologjia e p\u00ebrdorur \"autobus i p\u00ebrbashk\u00ebt\" vendos nj\u00eb s\u00ebr\u00eb kufizimesh:<\/p>\n<ul>\n<li>n\u00eb fundet e autobusit k\u00ebrkohen pajisje speciale - terminator\u00eb;<\/li>\n<li>kapaciteti i autobusit ndahet nd\u00ebrmjet t\u00eb gjitha pajisjeve;<\/li>\n<li>numri maksimal i pajisjeve q\u00eb lidhen nj\u00ebkoh\u00ebsisht \u00ebsht\u00eb i kufizuar.<\/li>\n<\/ul>\n<p>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/www.cablesdirect.com\/store\/p\/2877.aspx\"><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/caecf6cf48e6f0c219080f93e1224206.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><\/p>\n<p>Pajisjet n\u00eb autobusin identifikohen me nj\u00eb num\u00ebr unik, t\u00eb quajtur <b>SCSI Target ID<\/b>. \u00c7do nj\u00ebsi SCSI n\u00eb sistem paraqitet me t\u00eb pakt\u00ebn nj\u00eb nj\u00ebsin\u00eb logjike, adresa e s\u00eb cil\u00ebs ndodh sipas nj\u00eb numri unik brenda pajisjes fizike <b>Numri i Nj\u00ebsis\u00eb Logjike<\/b> (LUN).<\/p>\n<p><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/f85b1a966dbb47dea78320e27c9cbaac.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nUrimet n\u00eb SCSI d\u00ebrgohen n\u00eb form\u00ebn e <b>blok\u00ebve t\u00eb p\u00ebrshkrimit t\u00eb urdhrave<\/b> (Command Descriptor Block, CDB), t\u00eb p\u00ebrb\u00ebr\u00eb nga kodi i operacionit dhe parametrat e urdhrit. Standardi p\u00ebrshkruan m\u00eb shum\u00eb se 200 komanda, t\u00eb ndara n\u00eb kat\u00ebr kategori:<\/p>\n<ul>\n<li><b>T\u00eb detyrueshme<\/b> \u2014 duhet t\u00eb mb\u00ebshteten nga pajisja;<\/li>\n<li><b>T\u00eb optional<\/b> \u2014 mund t\u00eb zbatohen;<\/li>\n<li><b>Specifik p\u00ebr prodhuesin<\/b> \u2014 p\u00ebrdoren nga nj\u00eb prodhues i caktuar;<\/li>\n<li><b>T\u00eb vjet\u00ebruara<\/b> \u2014 komanda t\u00eb vjetra.<\/li>\n<\/ul>\n<p>\nMes shum\u00eb komandave, vet\u00ebm tre prej tyre jan\u00eb t\u00eb detyrueshme p\u00ebr pajisjet:<\/p>\n<ul>\n<li><b>TEST UNIT READY<\/b> \u2014 kontrolli i gatishm\u00ebris\u00eb s\u00eb pajisjes;<\/li>\n<li><b>REQUEST SENSE<\/b> \u2014 k\u00ebrkon kodin e gabimit t\u00eb urdhrit t\u00eb m\u00ebparsh\u00ebm;<\/li>\n<li><b>INQUIRY<\/b> \u2014 k\u00ebrkesa p\u00ebr karakteristikat kryesore t\u00eb pajisjes.<\/li>\n<\/ul>\n<p>\nPasi t\u00eb marr\u00eb dhe t\u00eb p\u00ebrpunoj\u00eb urdhrin, pajisja e synuar i d\u00ebrgon iniciatorit nj\u00eb kod statusi, i cili p\u00ebrshkruan rezultatin e ekzekutimit.<\/p>\n<p>P\u00ebrmir\u00ebsimi i m\u00ebtejsh\u00ebm i SCSI (specifikimet SCSI-2 dhe Ultra SCSI) zgjeroi list\u00ebn e komandave t\u00eb p\u00ebrdorura dhe rriti numrin e pajisjeve t\u00eb lidhura deri n\u00eb 16, nd\u00ebrsa shpejt\u00ebsia e transferimit t\u00eb t\u00eb dh\u00ebnave p\u00ebrmes autobusit arriti deri n\u00eb 640 MB\/s. Duke qen\u00eb se SCSI \u00ebsht\u00eb nj\u00eb nd\u00ebrfaqe paralele, rritja e frekuenc\u00ebs s\u00eb transferimit t\u00eb t\u00eb dh\u00ebnave u shoq\u00ebrua me nj\u00eb zvog\u00eblim t\u00eb gjat\u00ebsi maksimale t\u00eb kabllit, duke sjell\u00eb k\u00ebshtu disa inconvenienca n\u00eb p\u00ebrdorim.<\/p>\n<p>Nga standardi Ultra-3 SCSI, u prezantua mb\u00ebshtetje p\u00ebr \"lidhen e nxeht\u00eb\" \u2014 lidhjen e pajisjeve n\u00eb funksionim.<\/p>\n<p>SSD i par\u00eb i njohur me nd\u00ebrfaqen SCSI mund t\u00eb merret si M-Systems FFD-350, i dal\u00eb n\u00eb treg n\u00eb vitin 1995. Disku kishte nj\u00eb \u00e7mim t\u00eb lart\u00eb dhe nuk kishte nj\u00eb p\u00ebrhapje t\u00eb gjer\u00eb.<\/p>\n<p>Aktualisht, SCSI-ja paralele nuk \u00ebsht\u00eb nj\u00eb nd\u00ebrfaqe e njohur p\u00ebr lidhjen e disk\u00ebve, por grupi i komandave ende p\u00ebrdoret aktivisht n\u00eb nd\u00ebrfaqet USB dhe SAS.<\/p>\n<h2>ATA \/ PATA<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/0f152c456d01911a4e64b565741cb8cd.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nInterfaci <b>ATA<\/b> (Advanced Technology Attachment), gjithashtu e njohur si <b>PATA<\/b> (Parallel ATA) u shpik nga kompania Western Digital n\u00eb vitin 1986. Emri marketingut t\u00eb standardit IDE (angl. Integrated Drive Electronics \u2014 \u00abelektronika e nd\u00ebrtuar n\u00eb drive\u00bb) theksoi nj\u00eb novacion t\u00eb r\u00ebnd\u00ebsish\u00ebm: kontrolluesi i drive-it ishte i nd\u00ebrtuar brenda drive-it dhe jo n\u00eb nj\u00eb kartel\u00eb t\u00eb ve\u00e7ant\u00eb zgjerimi.<\/p>\n<p>Vendimi p\u00ebr t\u00eb vendosur kontrolluesin brenda drive-it zgjidhte menj\u00ebher\u00eb disa probleme. S\u00eb pari, u zvog\u00eblua distanca nga nj\u00ebsia ruajt\u00ebse tek kontrolluesi, gj\u00eb q\u00eb ndihmoi n\u00eb p\u00ebrmir\u00ebsimin e karakteristikave t\u00eb nj\u00ebsis\u00eb ruajt\u00ebse. S\u00eb dyti, kontrolluesi i nd\u00ebrtuar ishte \u00abi p\u00ebrshtatur\u00bb vet\u00ebm p\u00ebr nj\u00eb tip t\u00eb caktuar drive-i dhe, p\u00ebr rrjedhoj\u00eb, ishte m\u00eb i lir\u00eb.<\/p>\n<p><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/de2944768a139aeccef20e1688ed7baf.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nATA, ashtu si SCSI, p\u00ebrdor nj\u00eb m\u00ebnyr\u00eb t\u00eb paralel p\u00ebr hyrje-dalje, q\u00eb reflektohet n\u00eb kabllot q\u00eb p\u00ebrdoren. P\u00ebr t\u00eb lidhur disqet me p\u00ebrdorimin e nd\u00ebrfaqes IDE k\u00ebrkohen kabllo me 40 fije, gjithashtu t\u00eb njohura si shlet\u00ebza. N\u00eb specifikimet m\u00eb t\u00eb vonshme p\u00ebrdoren shlet\u00ebzat me 80 fije: mbi gjysm\u00ebn e t\u00eb cilave jan\u00eb p\u00ebrjashtuar p\u00ebr t\u00eb ulur interferenc\u00ebn n\u00eb frekuencat e larta.<\/p>\n<p>N\u00eb shpejt\u00ebsin\u00eb ATA ka nga dy deri n\u00eb kat\u00ebr lidhje, nj\u00ebra prej t\u00eb cilave lidhet me pllak\u00ebn kryesore, nd\u00ebrsa t\u00eb tjerat lidhen me pajisjet ruajt\u00ebse. Kur lidhen dy pajisje me nj\u00eb shpejt\u00ebsi, nj\u00ebra prej tyre duhet t\u00eb konfigurohet si <b>Master<\/b>, dhe tjetra si <b>Slave<\/b>. Pajisja e tret\u00eb mund t\u00eb lidhet ekskluzivisht n\u00eb m\u00ebnyr\u00ebn \"lexim vet\u00ebm\".<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"http:\/\/www.informit.com\/articles\/article.aspx?p=2028834&amp;seqNum=3\"><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/91490f1a349198d18c6e4947fc53476d.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nPozita e jumpers p\u00ebrcakton rolin e pajisjes specifike. Termat Master dhe Slave n\u00eb lidhje me pajisjet nuk jan\u00eb krejt\u00ebsisht t\u00eb sakt\u00eb, pasi n\u00eb raport me kontrolluesin, t\u00eb gjitha pajisjet e lidhura jan\u00eb Slaves.<\/p>\n<p>Nj\u00eb novitet i ve\u00e7ant\u00eb n\u00eb ATA-3 \u00ebsht\u00eb shfaqja e <b>Self-Monitoring<\/b>, <b>Analysis and Reporting Technology (S.M.A.R.T.)<\/b>. Pes\u00eb kompani (IBM, Seagate, Quantum, Conner dhe Western Digital) bashkuan forcat dhe standardizuan teknologjin\u00eb e vler\u00ebsimit t\u00eb gjendjes s\u00eb disqeve ruajt\u00ebse.<\/p>\n<p>Mb\u00ebshtetje p\u00ebr disqet e ngurt\u00eb u shfaq me versionin e kat\u00ebrt t\u00eb standardit, i l\u00ebshuar n\u00eb vitin 1998. Ky version i standardit siguroi shpejt\u00ebsi t\u00eb transmetimit t\u00eb t\u00eb dh\u00ebnave deri n\u00eb 33.3 MB\/s.<\/p>\n<p>Standarti parashtron k\u00ebrkesa t\u00eb rrepta p\u00ebr shpejt\u00ebsit\u00eb ATA:<\/p>\n<ul>\n<li>shpejt\u00ebsia duhet t\u00eb jet\u00eb patjet\u00ebr e shesht\u00eb;<\/li>\n<li>gjat\u00ebsia maksimale e shpejt\u00ebsis\u00eb \u00ebsht\u00eb 18 in\u00e7 (45.7 centimetra).<\/li>\n<\/ul>\n<p>\nKablimi i shkurt\u00ebr dhe i gjer\u00eb ishte i pak\u00ebndsh\u00ebm dhe pengonte ftohjen. Rritja e shpejt\u00ebsis\u00eb s\u00eb transferimit me \u00e7do version t\u00eb ri t\u00eb standardit b\u00ebhej gjithnj\u00eb e m\u00eb e v\u00ebshtir\u00eb, dhe ATA-7 zgjidhi k\u00ebt\u00eb problem n\u00eb m\u00ebnyr\u00eb radikale: interfejsi paralel u z\u00ebvend\u00ebsua me nj\u00eb t\u00eb nj\u00ebansh\u00ebm. Pas k\u00ebsaj, ATA mori fjal\u00ebn Paralel dhe filloi t\u00eb quhej PATA, dhe versioni i shtat\u00eb i standardit mori nj\u00eb em\u00ebr tjet\u00ebr \u2014 Serial ATA. Num\u00ebrimi i versioneve SATA filloi nga nj\u00eb.<\/p>\n<h2>SATA<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/62bbd54846d285ac7545fd019935f4a4.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nStandardi Serial ATA (SATA) u prezantua m\u00eb 7 janar 2003 dhe zgjidhi problemet e parapriosit t\u00eb tij me k\u00ebto ndryshime:<\/p>\n<ul>\n<li>porti paralel u z\u00ebvend\u00ebsua me nj\u00eb t\u00eb nj\u00ebansh\u00ebm;<\/li>\n<li>kablimi i gjer\u00eb 80-fibror u z\u00ebvend\u00ebsua me nj\u00eb 7-fibror;<\/li>\n<li>topologjia 'n\u00eb autobusin e p\u00ebrbashk\u00ebt' u z\u00ebvend\u00ebsua me lidhjen 'pik\u00eb n\u00eb pik\u00eb'.<\/li>\n<\/ul>\n<p>\nMegjith\u00ebse standardi SATA 1.0 (SATA\/150, 150 MB\/s) ishte pak m\u00eb i shpejt\u00eb se ATA-6 (UltraDMA\/130, 130 MB\/s), kalimi n\u00eb m\u00ebnyr\u00ebn e t\u00eb dh\u00ebnave n\u00eb nj\u00ebanshm\u00ebri ishte 'p\u00ebrgatitja e terrenit' p\u00ebr rritjen e shpejt\u00ebsive.<\/p>\n<p>Gjasht\u00ebmb\u00ebdhjet\u00eb linja sinjalizimi p\u00ebr transferimin e t\u00eb dh\u00ebnave n\u00eb ATA u z\u00ebvend\u00ebsuan me dy lidhje t\u00eb ftuara: nj\u00eb p\u00ebr transfert\u00ebn dhe nj\u00eb p\u00ebr marrjen. Konektor\u00ebt SATA jan\u00eb projektuar p\u00ebr nj\u00eb q\u00ebndrueshm\u00ebri m\u00eb t\u00eb madhe ndaj rind\u00ebrtimeve t\u00eb shumta, dhe specifikimi SATA 1.0 e b\u00ebri t\u00eb mundur \"lidhen n\u00eb nxeht\u00eb\" (Hot Plug).<\/p>\n<blockquote><p><b>Disa pin\u00eb n\u00eb disk jan\u00eb m\u00eb t\u00eb shkurt\u00ebr se t\u00eb tjer\u00ebt. Kjo \u00ebsht\u00eb b\u00ebr\u00eb p\u00ebr t\u00eb mb\u00ebshtetur \"z\u00ebvend\u00ebsimin n\u00eb nxeht\u00eb\" (Hot Swap). Gjat\u00eb procesit t\u00eb z\u00ebvend\u00ebsimit, pajisja \" humbet\" dhe \"gjen\" linjat n\u00eb nj\u00eb rend t\u00eb paracaktuar.<\/b><\/p><\/blockquote>\n<p>\nPak m\u00eb shum\u00eb se nj\u00eb vit m\u00eb von\u00eb, n\u00eb prill 2004, doli versioni i dyt\u00eb i specifikimit SATA. P\u00ebrve\u00e7 p\u00ebrshpejtimit deri n\u00eb 3 Gbit\/s, n\u00eb SATA 2.0 u fut teknologjia <b>K\u00ebrkesa Natyrore e Komandave<\/b> (NCQ). Pajisjet q\u00eb mb\u00ebshtesin NCQ jan\u00eb n\u00eb gjendje t\u00eb organizojn\u00eb vet\u00eb rendin e ekzekutimit t\u00eb komandave t\u00eb pranuara p\u00ebr t\u00eb arritur performanc\u00ebn maksimale.<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/www.newegg.com\/red-rocstor-6-data-transfer-cable\/p\/0ZF-00S7-00004\"><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/5a10fbfb30d403d9700136018a0d94eb.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nT\u00eb tre vitet pasuese, Grupi i Pun\u00ebs SATA punoi p\u00ebr p\u00ebrmir\u00ebsimin e specifikimit ekzistues dhe n\u00eb versionin 2.6 u shfaq\u00ebn konektor\u00ebt e kompakti Slimline dhe micro SATA (uSATA). K\u00ebta konektor\u00eb jan\u00eb nj\u00eb kopje e zvog\u00ebluar e konektorit origjinal SATA dhe jan\u00eb projektuar p\u00ebr lexues optik\u00eb dhe disqe t\u00eb vegj\u00ebl n\u00eb laptop\u00eb.<\/p>\n<p>Megjithat\u00eb, kapaciteti i gjenerat\u00ebs s\u00eb dyt\u00eb SATA ishte i mjaftuesh\u00ebm p\u00ebr disqet e forta, por disqet SSD k\u00ebrkonin m\u00eb shum\u00eb. M\u00eb maj 2009 doli versioni i tret\u00eb i specifikimit SATA me kapacitetin e rritur n\u00eb 6 Gbit\/s.<\/p>\n<p><noindex><a rel=\"nofollow\" href=\"https:\/\/windowstips.ru\/chto-takoe-msata-ssd-i-chem-on-mozhet-byt-polezen-osobenno-esli-vy-ne-udovletvoreny-obshhej-skorostyu-vashego-noutbuka\"><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/0a72172e33304d39dc8fcebc24aaca71.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nV\u00ebmendje t\u00eb ve\u00e7ant\u00eb disqet SSD mor\u00ebn n\u00eb redaksin\u00eb SATA 3.1. U prezantua konektori Mini-SATA (mSATA), i destinuar p\u00ebr t\u00eb lidhur disqet SSD n\u00eb laptop\u00eb. Ndryshe nga Slimline dhe uSATA, konektori i ri ishte ngjash\u00ebm me PCIe Mini, megjithat\u00eb nuk ishte elektrikisht i nd\u00ebrlidhur me PCIe. P\u00ebrve\u00e7 konektorit t\u00eb ri, SATA 3.1 mund t\u00eb mburej me mund\u00ebsin\u00eb e p\u00ebrpunimit t\u00eb komandave TRIM n\u00eb radh\u00eb me komandat e leximit dhe shkruajtjes.<\/p>\n<blockquote><p><b>Komanda TRIM e informon disqin SSD p\u00ebr blloqet e t\u00eb dh\u00ebnave q\u00eb nuk kan\u00eb ngarkes\u00eb t\u00eb dobishme. Deri n\u00eb SATA 3.1, ekzekutimi i k\u00ebsaj komande \u00e7onte n\u00eb rivendosjen e caches dhe pezullimin e operacioneve t\u00eb hyrjes-daljes me ekzekutimin e m\u00ebvonsh\u00ebm t\u00eb komand\u00ebs TRIM. Ky qasje p\u00ebrkeq\u00ebsonte performanc\u00ebn e disqit gjat\u00eb operacioneve t\u00eb fshirjes.<\/b><\/p><\/blockquote>\n<p>\nSpecifikimi SATA nuk iu p\u00ebrshtat dot rritjes s\u00eb shpejt\u00ebsis\u00eb s\u00eb qasjes te disqet solid-state, duke \u00e7uar n\u00eb shfaqjen n\u00eb vitin 2013 t\u00eb nj\u00eb kompromisi t\u00eb quajtur SATA Express n\u00eb standartin SATA 3.2. N\u00eb vend q\u00eb t\u00eb dyfishohej s\u00ebrish kapaciteti i SATA, zhvilluesit shfryt\u00ebzuan autobusin e njohur PCIe, i cili ka nj\u00eb shpejt\u00ebsi mbi 6 Gbit\/s. Disk\u00ebt q\u00eb mb\u00ebshtesin SATA Express mor\u00ebn nj\u00eb format t\u00eb ri t\u00eb quajtur M.2.<\/p>\n<h2>SAS<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/b962c09d48c8aca6a19381d6d8866558.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nStandardi SCSI, i cili konkurron me ATA, gjithashtu nuk q\u00ebndroi m\u00ebnjan\u00eb dhe vet\u00ebm nj\u00eb vit pas shfaqjes s\u00eb Serial ATA, n\u00eb vitin 2004, u riformulua n\u00eb nj\u00eb nd\u00ebrfaqe seriale. Emri i ri p\u00ebr k\u00ebt\u00eb nd\u00ebrfaqe \u00ebsht\u00eb <b>Serial Attached SCSI<\/b> (SAS).<\/p>\n<p>Megjith\u00ebse SAS trash\u00ebgoi grupin e komandave SCSI, ndryshimet ishin t\u00eb m\u00ebdha:<\/p>\n<ul>\n<li>n\u00eb nj\u00eb nd\u00ebrfaqe seriale;<\/li>\n<li>kablloja 29-pik\u00ebshe me energji;<\/li>\n<li>lidhje \"pik\u00eb-pik\u00eb\"<\/li>\n<\/ul>\n<p>\nTerminologjia SCSI gjithashtu u trash\u00ebgua. Kontrolluesi quhet ende iniciator, nd\u00ebrsa disqet e lidhura quhen objektiva. T\u00eb gjith\u00eb objektivat dhe iniciatori formojn\u00eb nj\u00eb domen SAS. N\u00eb SAS, kapaciteti i lidhjes nuk varet nga numri i pajisjeve n\u00eb domen, sepse \u00e7do pajisje p\u00ebrdor kanalin e saj t\u00eb dedikuar.<\/p>\n<p>Numri maksimal i pajisjeve q\u00eb mund t\u00eb lidhen n\u00eb m\u00ebnyr\u00eb t\u00eb nj\u00ebkohshme n\u00eb domenin SAS sipas specifikimeve tejkalon 16 mij\u00eb, dhe n\u00eb vend t\u00eb ID SCSI p\u00ebr adresimin p\u00ebrdoret identifikuesi <b>Emri Bot\u00ebror<\/b> (WWN).<\/p>\n<blockquote><p><b>WWN \u00ebsht\u00eb nj\u00eb identifikues unik me nj\u00eb gjat\u00ebsi prej 16 byte, e ngjashme me adres\u00ebn MAC p\u00ebr pajisjet SAS.<\/b><\/p><\/blockquote>\n<p>\n<noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/Serial_Attached_SCSI\"><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/0659809e755f33639caaf83606dce40d.jpeg\" style=\"display:block;margin: 0 auto;\" \/><\/a><\/noindex><br \/>\nPavar\u00ebsisht ngjashm\u00ebris\u00eb s\u00eb porteve SAS dhe SATA, k\u00ebto standarde nuk jan\u00eb krejt\u00ebsisht t\u00eb p\u00ebrputhshme. Megjithat\u00eb, nj\u00eb disk SATA mund t\u00eb lidhet n\u00eb nj\u00eb konektor SAS, por jo e kund\u00ebrta. Kompatibiliteti midis disqeve SATA dhe domenit SAS sigurohet p\u00ebrmes protokollit SATA Tunneling Protocol (STP).<\/p>\n<p>Versioni i par\u00eb i standardit SAS-1 ka nj\u00eb kapacitet kalimi prej 3 Gbit\/s, nd\u00ebrsa versioni m\u00eb i fundit, SAS-4, e p\u00ebrmir\u00ebsoi k\u00ebt\u00eb tregues n\u00eb 7 her\u00eb: 22,5 Gbit\/s.<\/p>\n<h2>PCIe<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/05251167ad57703662c9be5df62ca85f.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nPeripheral Component Interconnect Express (PCI Express, PCIe) \u00ebsht\u00eb nj\u00eb nd\u00ebrfaqe seriale p\u00ebr transmetimin e t\u00eb dh\u00ebnave, e cila u shfaq n\u00eb vitin 2002. Zhvillimi u fillua nga kompania Intel dhe m\u00eb pas u kalua n\u00eb nj\u00eb organizat\u00eb speciale \u2014 PCI Special Interest Group.<\/p>\n<p>Ndarja seriale PCIe nuk ishte p\u00ebrjashtim dhe u b\u00eb vazhdim logjik i PCI-s\u00eb paralel, i cili \u00ebsht\u00eb e destinuar p\u00ebr lidhjen e kartave extension.<\/p>\n<p>PCI Express dallon shum\u00eb ndryshe nga SATA dhe SAS. Nd\u00ebrfaqja PCIe ka nj\u00eb num\u00ebr t\u00eb ndryshuesh\u00ebm linjash. Numri i linjave \u00ebsht\u00eb i barabart\u00eb me fuqit\u00eb e dyshes dhe varion nga 1 n\u00eb 16.<\/p>\n<p>Termi \u00ablinj\u00eb\u00bb n\u00eb PCIe nuk e p\u00ebrfaq\u00ebson nj\u00eb linj\u00eb specifike sinjalizimi, por nj\u00eb kanal t\u00eb ve\u00e7ant\u00eb komunikimi me dy fulle, q\u00eb p\u00ebrb\u00ebhet nga linjat e ardhshme:<\/p>\n<ul>\n<li>pranimi+ dhe pranimi-;<\/li>\n<li>transferimi+ dhe transferimi-;<\/li>\n<li>kat\u00ebr tela t\u00eb tok\u00ebs.<\/li>\n<\/ul>\n<p>\nNumri i linjave PCIe ndikon drejtp\u00ebrdrejt n\u00eb kapacitetin maksimal t\u00eb shkarkimit t\u00eb lidhjes. Standardi modern PCI Express 4.0 lejon arritjen deri n\u00eb 1.9 GB\/s p\u00ebr nj\u00eb linj\u00eb, dhe 31.5 GB\/s duke p\u00ebrdorur 16 linja.<\/p>\n<p><img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/e3c4ec567c596348ebba75ff1c88c933.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nAlegjimet e disk\u00ebve SSD po rriten shum\u00eb shpejt. Si SATA ashtu edhe SAS nuk arrijn\u00eb t\u00eb rrisin kapacitetin e tyre p\u00ebr t\u00eb \u00abndjekur\u00bb SSD, q\u00eb \u00e7oi n\u00eb shfaqjen e disqeve SSD me lidhje PCIe.<\/p>\n<blockquote><p><b>Megjith\u00ebse kartat PCIe Add-In fiksohen me nj\u00eb vid\u00eb, PCIe mb\u00ebshtet \u00abnd\u00ebrrimin n\u00eb flak\u00eb\u00bb. Pin\u00ebt e shkurt\u00ebr PRSNT (angl. present \u2014 e pranishme) lejojn\u00eb t\u00eb sigurohet q\u00eb karta \u00ebsht\u00eb instaluar plot\u00ebsisht n\u00eb slot.<\/b><\/p><\/blockquote>\n<p>\nDisqet SSD q\u00eb lidhen p\u00ebrmes PCIe rregullohen nga nj\u00eb standard t\u00eb ve\u00e7ant\u00eb <b>Specifikimi i Nd\u00ebrfaqes s\u00eb Kontrolluesit t\u00eb Memoris\u00eb Jo-T\u00eb Folur<\/b> dhe jan\u00eb realizuar n\u00eb nj\u00eb shum\u00ebllojshm\u00ebri formash, por p\u00ebr to do t\u00eb flasim n\u00eb pjes\u00ebn tjet\u00ebr.<\/p>\n<h2>Ruajt\u00ebsit e larg\u00ebt<\/h2>\n<p>\nMe krijimin e objekteve t\u00eb m\u00ebdha t\u00eb ruajtjes s\u00eb t\u00eb dh\u00ebnave erdhi nevoja p\u00ebr protokolle q\u00eb lejojn\u00eb lidhjen e ruajt\u00ebsve t\u00eb vendosur jasht\u00eb serverit. Zgjidhja e par\u00eb n\u00eb k\u00ebt\u00eb fush\u00eb ishte <b>Internet SCSI<\/b> (iSCSI), i zhvilluar nga kompanit\u00eb IBM dhe Cisco n\u00eb vitin 1998.<\/p>\n<p>Ideja e protokollit iSCSI \u00ebsht\u00eb e thjesht\u00eb: komandat SCSI 'mb\u00ebshtillen' n\u00eb paketa TCP\/IP dhe transmetohen n\u00eb rrjet. Pavar\u00ebsisht nga lidhja e larg\u00ebt, krijohet iluzioni p\u00ebr klient\u00ebt se ruajt\u00ebsi \u00ebsht\u00eb i lidhur lokal. Rrjeti i ruajtjes s\u00eb t\u00eb dh\u00ebnave (Storage Area Network, SAN), i bazuar n\u00eb iSCSI, mund t\u00eb nd\u00ebrtohet mbi infrastruktur\u00ebn ekzistuese t\u00eb rrjetit. P\u00ebrdorimi i iSCSI ul ndjesh\u00ebm shpenzimet p\u00ebr organizimin e SAN.<\/p>\n<p>iSCSI ka nj\u00eb variant 'premium' \u2014 <b>Fibre Channel Protocol<\/b> (FCP). SAN me p\u00ebrdorimin e FCP nd\u00ebrtohet mbi linja t\u00eb dedikuara fibra optike. Ky qasje k\u00ebrkon pajisje shtes\u00eb rrjetike optike, por ofron stabilitet dhe kapacitet t\u00eb lart\u00eb kalimi.<\/p>\n<blockquote><p><b>Ka \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u043e protokolesh p\u00ebr d\u00ebrgimin e komandave SCSI p\u00ebrmes rrjeteve kompjuterike. Megjithat\u00eb, ekziston vet\u00ebm nj\u00eb standard q\u00eb zgjidh problemin e kund\u00ebrt dhe lejon d\u00ebrgimin e paketave IP mbi shiritin SCSI \u2014 <noindex><a rel=\"nofollow\" href=\"https:\/\/www.rfc-editor.org\/rfc\/rfc2143.txt\">IP-over-SCSI<\/a><\/noindex>.<\/b><\/p><\/blockquote>\n<p>\nShumica e protokolleve p\u00ebr organizimin e SAN p\u00ebrdorin nj\u00eb p\u00ebrmbledhje komandash SCSI p\u00ebr t\u00eb menaxhuar disqet, por ka edhe p\u00ebrjashtime, si\u00e7 \u00ebsht\u00eb e thjesht\u00eb <b>ATA over Ethernet<\/b> (AoE). Protokolli AoE d\u00ebrgon komandat ATA n\u00eb paketat Ethernet, por n\u00eb sistem disqet shfaqen si SCSI.<\/p>\n<p>Me shfaqjen e disqeve NVM Express, protokollet iSCSI dhe FCP nuk p\u00ebrmbushin m\u00eb k\u00ebrkesat n\u00eb rritje t\u00eb disqeve SSD. Dy zgjidhje u shfaq\u00ebn:<\/p>\n<ul>\n<li>nxjerrja e shiritit PCI Express p\u00ebrtej serverit;<\/li>\n<li>krijimi i protokollit NVMe over Fabrics.<\/li>\n<\/ul>\n<p>\nNxjerrja e shiritit PCIe k\u00ebrkon krijimin e pajisjeve komplekse t\u00eb komutimit, por nuk sjell ndryshime n\u00eb protokoll.<\/p>\n<p>Protokolli NVMe over Fabrics \u00ebsht\u00eb b\u00ebr\u00eb nj\u00eb alternativ\u00eb e mir\u00eb p\u00ebr iSCSI dhe FCP. N\u00eb NVMe-oF p\u00ebrdoren linjat optike dhe grupi i komandave NVM Express.<\/p>\n<h2>DDR-T<\/h2>\n<p>\n<img decoding=\"async\" alt=\"Hyrja n\u00eb SSD. Pjesa 2. Interfejsi\" src=\"\/wp-content\/uploads\/2019\/12\/3fe9daef1cc011973e9cfc48e9ffe8d2.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nStandardet iSCSI dhe NVMe-oF zgjidhin problemin e lidhjes s\u00eb disqeve t\u00eb larg\u00ebt si lokale, nd\u00ebrsa kompania Intel ndoqi nj\u00eb rrug\u00eb tjet\u00ebr dhe e afroi maksimalisht diskun lokal me procesorin. Zgjedhja ra mbi slotet DIMM, n\u00eb t\u00eb cilat lidhet kujtesa e p\u00ebrkohshme. Kapaciteti maksimal i kanalit DDR4 \u00ebsht\u00eb 25 GB\/s, q\u00eb tejkalon ndjesh\u00ebm shpejt\u00ebsin\u00eb e busit PCIe. K\u00ebshtu lindi kujtesa stabil e Intel\u00ae Optane\u2122 DC Memory.<\/p>\n<p>P\u00ebr lidhjen e kujtes\u00ebs n\u00eb slotet DIMM, u shpik protokolli <b>DDR-T<\/b>, fizikisht dhe elektrikisht e p\u00ebrputhshme me DDR4, por k\u00ebrkon nj\u00eb kontrollues t\u00eb ve\u00e7ant\u00eb q\u00eb sheh ndryshimin midis modulit t\u00eb kujtes\u00ebs dhe kujtes\u00ebs s\u00eb ngurt\u00eb. Shpejt\u00ebsia e qasjes n\u00eb kujtes\u00ebn e ngurt\u00eb \u00ebsht\u00eb m\u00eb e ul\u00ebt se ajo e kujtes\u00ebs s\u00eb p\u00ebrkohshme, por m\u00eb e lart\u00eb se ajo e NVMe.<\/p>\n<p>Protokolli DDR-T \u00ebsht\u00eb n\u00eb dispozicion vet\u00ebm me procesor\u00ebt Intel\u00ae t\u00eb gjenerat\u00ebs Cascade Lake ose m\u00eb t\u00eb rinj.<\/p>\n<h2>P\u00ebrfundimi<\/h2>\n<p>\nG almost all interfaces have gone a long way in their development from a serial to a parallel data transmission method. The speeds of solid-state drives are growing rapidly; just yesterday, solid-state drives were a novelty, and today NVMe no longer causes any particular surprise.<\/p>\n<blockquote><p><b>N\u00eb laboratorin ton\u00eb <noindex><a rel=\"nofollow\" href=\"https:\/\/selectel.ru\/lab\/\">Selectel Lab<\/a><\/noindex> mund t\u00eb testi vet\u00eb SSD dhe disqet NVMe.<\/b><\/p><\/blockquote>\n<p class=\"for_users_only_msg\">Vet\u00ebm p\u00ebrdoruesit e regjistruar mund t\u00eb marrin pjes\u00eb n\u00eb anket\u00eb. <noindex><a rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/auth\/login\/\">Hyni<\/a><\/noindex>, ju lutemi.<\/p>\n<h2 class=\"default-block__polling-title\">A do t\u00eb z\u00ebvend\u00ebsojn\u00eb disqet NVMe disqet tradicionale SSD n\u00eb t\u00eb ardhmen e af\u00ebrt?<\/h2>\n<ul class=\"poll-result\">\n<li class=\"poll-result__item\">\n<p>                <strong class=\"poll-result__data-percent  poll-result__data-percent_winner\">55.5%<\/strong>Po100<\/p>\n<\/li>\n<li class=\"poll-result__item\">\n<p>                <strong class=\"poll-result__data-percent\">44.4%<\/strong>Jo80<\/p>\n<\/li>\n<\/ul>\n<p>    180 p\u00ebrdorues kan\u00eb votuar. 28 p\u00ebrdorues kan\u00eb abstenuar.<br \/>\n<br \/>Burimi: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/selectel\/blog\/478684\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0412 \u043f\u0440\u043e\u0448\u043b\u043e\u0439 \u0447\u0430\u0441\u0442\u0438 \u0446\u0438\u043a\u043b\u0430 \u00ab\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0432 SSD\u00bb \u043c\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u043b\u0438 \u043f\u0440\u043e \u0438\u0441\u0442\u043e\u0440\u0438\u044e \u043f\u043e\u044f\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0438\u0441\u043a\u043e\u0432. \u0412\u0442\u043e\u0440\u0430\u044f \u0447\u0430\u0441\u0442\u044c \u0440\u0430\u0441\u0441\u043a\u0430\u0436\u0435\u0442 \u043f\u0440\u043e \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u044b \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u0441 \u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u044f\u043c\u0438. \u041e\u0431\u0449\u0435\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u043c \u0438 \u043f\u0435\u0440\u0438\u0444\u0435\u0440\u0438\u0439\u043d\u044b\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0437\u0430\u0440\u0430\u043d\u0435\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u043c\u0438 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f\u043c\u0438, \u043d\u0430\u0437\u044b\u0432\u0430\u0435\u043c\u044b\u043c\u0438 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430\u043c\u0438. \u042d\u0442\u0438 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f \u0440\u0435\u0433\u043b\u0430\u043c\u0435\u043d\u0442\u0438\u0440\u0443\u044e\u0442 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f. \u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u2014 \u0441\u043e\u0432\u043e\u043a\u0443\u043f\u043d\u043e\u0441\u0442\u044c \u0441\u0440\u0435\u0434\u0441\u0442\u0432, \u043c\u0435\u0442\u043e\u0434\u043e\u0432 \u0438 \u043f\u0440\u0430\u0432\u0438\u043b \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u043c\u0435\u0436\u0434\u0443 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u0430\u043c\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-53854","post","type-post","status-publish","format-standard","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0412 \u043f\u0440\u043e\u0448\u043b\u043e\u0439 \u0447\u0430\u0441\u0442\u0438 \u0446\u0438\u043a\u043b\u0430 \u00ab\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0432 SSD\u00bb \u043c\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u043b\u0438 \u043f\u0440\u043e \u0438\u0441\u0442\u043e\u0440\u0438\u044e \u043f\u043e\u044f\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0438\u0441\u043a\u043e\u0432. \u0412\u0442\u043e\u0440\u0430\u044f \u0447\u0430\u0441\u0442\u044c \u0440\u0430\u0441\u0441\u043a\u0430\u0436\u0435\u0442 \u043f\u0440\u043e \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u044b \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u0441 \u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u044f\u043c\u0438. \u041e\u0431\u0449\u0435\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u043c \u0438 \u043f\u0435\u0440\u0438\u0444\u0435\u0440\u0438\u0439\u043d\u044b\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0437\u0430\u0440\u0430\u043d\u0435\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u043c\u0438 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f\u043c\u0438, \u043d\u0430\u0437\u044b\u0432\u0430\u0435\u043c\u044b\u043c\u0438 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430\u043c\u0438. \u042d\u0442\u0438 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f \u0440\u0435\u0433\u043b\u0430\u043c\u0435\u043d\u0442\u0438\u0440\u0443\u044e\u0442 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f. \u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u2014 \u0441\u043e\u0432\u043e\u043a\u0443\u043f\u043d\u043e\u0441\u0442\u044c \u0441\u0440\u0435\u0434\u0441\u0442\u0432, \u043c\u0435\u0442\u043e\u0434\u043e\u0432 \u0438 \u043f\u0440\u0430\u0432\u0438\u043b \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u043c\u0435\u0436\u0434\u0443 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u0430\u043c\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/vvedenie-v-ssd-chast-2-interfejsnaya\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"sq_AL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0432 SSD. \u0427\u0430\u0441\u0442\u044c 2. \u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u043d\u0430\u044f | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0412 \u043f\u0440\u043e\u0448\u043b\u043e\u0439 \u0447\u0430\u0441\u0442\u0438 \u0446\u0438\u043a\u043b\u0430 \u00ab\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0432 SSD\u00bb \u043c\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u043b\u0438 \u043f\u0440\u043e \u0438\u0441\u0442\u043e\u0440\u0438\u044e \u043f\u043e\u044f\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0438\u0441\u043a\u043e\u0432. \u0412\u0442\u043e\u0440\u0430\u044f \u0447\u0430\u0441\u0442\u044c \u0440\u0430\u0441\u0441\u043a\u0430\u0436\u0435\u0442 \u043f\u0440\u043e \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u044b \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u0441 \u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u044f\u043c\u0438. \u041e\u0431\u0449\u0435\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u043c \u0438 \u043f\u0435\u0440\u0438\u0444\u0435\u0440\u0438\u0439\u043d\u044b\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0437\u0430\u0440\u0430\u043d\u0435\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u043c\u0438 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f\u043c\u0438, \u043d\u0430\u0437\u044b\u0432\u0430\u0435\u043c\u044b\u043c\u0438 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430\u043c\u0438. \u042d\u0442\u0438 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f \u0440\u0435\u0433\u043b\u0430\u043c\u0435\u043d\u0442\u0438\u0440\u0443\u044e\u0442 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f. \u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u2014 \u0441\u043e\u0432\u043e\u043a\u0443\u043f\u043d\u043e\u0441\u0442\u044c \u0441\u0440\u0435\u0434\u0441\u0442\u0432, \u043c\u0435\u0442\u043e\u0434\u043e\u0432 \u0438 \u043f\u0440\u0430\u0432\u0438\u043b \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u043c\u0435\u0436\u0434\u0443 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u0430\u043c\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/vvedenie-v-ssd-chast-2-interfejsnaya\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-12-11T21:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-02-18T11:01:47+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Prezantimi n\u00eb SSD. Pjesa 2. Nd\u00ebrfaq\u00ebsimi | ProHoster","description":"N\u00eb pjes\u00ebn e kaluar t\u00eb ciklit \"Prezantimi n\u00eb SSD\", ne fol\u00ebm rreth historis\u00eb s\u00eb shfaqjes s\u00eb disqeve. Pjesa e dyt\u00eb do t\u00eb flas\u00eb p\u00ebr nd\u00ebrfaqet e bashk\u00ebpunimit me ruajt\u00ebsit. Komunikimi midis procesorit dhe pajisjeve periferike ndodh sipas marr\u00ebveshjeve t\u00eb parapara, t\u00eb quajtura nd\u00ebrfaqe. K\u00ebto marr\u00ebveshje rregullojn\u00eb nivelin fizik dhe programor t\u00eb bashk\u00ebpunimit. Nd\u00ebrfaqja \u00ebsht\u00eb nj\u00eb p\u00ebrmbledhje e mjeteve, metodave dhe rregullave t\u00eb bashk\u00ebpunimit midis elementeve t\u00eb sistemit.","canonical_url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/vvedenie-v-ssd-chast-2-interfejsnaya","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sq_AL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0432 SSD. \u0427\u0430\u0441\u0442\u044c 2. \u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u043d\u0430\u044f | ProHoster","og:description":"\u0412 \u043f\u0440\u043e\u0448\u043b\u043e\u0439 \u0447\u0430\u0441\u0442\u0438 \u0446\u0438\u043a\u043b\u0430 \u00ab\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0432 SSD\u00bb \u043c\u044b \u0440\u0430\u0441\u0441\u043a\u0430\u0437\u0430\u043b\u0438 \u043f\u0440\u043e \u0438\u0441\u0442\u043e\u0440\u0438\u044e \u043f\u043e\u044f\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0438\u0441\u043a\u043e\u0432. \u0412\u0442\u043e\u0440\u0430\u044f \u0447\u0430\u0441\u0442\u044c \u0440\u0430\u0441\u0441\u043a\u0430\u0436\u0435\u0442 \u043f\u0440\u043e \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u044b \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u0441 \u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u044f\u043c\u0438. \u041e\u0431\u0449\u0435\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u043c \u0438 \u043f\u0435\u0440\u0438\u0444\u0435\u0440\u0438\u0439\u043d\u044b\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0437\u0430\u0440\u0430\u043d\u0435\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u043c\u0438 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f\u043c\u0438, \u043d\u0430\u0437\u044b\u0432\u0430\u0435\u043c\u044b\u043c\u0438 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430\u043c\u0438. \u042d\u0442\u0438 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f \u0440\u0435\u0433\u043b\u0430\u043c\u0435\u043d\u0442\u0438\u0440\u0443\u044e\u0442 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f. \u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u2014 \u0441\u043e\u0432\u043e\u043a\u0443\u043f\u043d\u043e\u0441\u0442\u044c \u0441\u0440\u0435\u0434\u0441\u0442\u0432, \u043c\u0435\u0442\u043e\u0434\u043e\u0432 \u0438 \u043f\u0440\u0430\u0432\u0438\u043b \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u043c\u0435\u0436\u0434\u0443 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u0430\u043c\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.","og:url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/vvedenie-v-ssd-chast-2-interfejsnaya","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-12-11T21:00:00+00:00","article:modified_time":"2020-02-18T11:01:47+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"53854","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-01-24 09:02:22","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 13:12:42","updated":"2026-01-24 09:02:22"},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/53854","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/comments?post=53854"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/53854\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media?parent=53854"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/categories?post=53854"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/tags?post=53854"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}