{"id":56401,"date":"2020-02-12T00:00:00","date_gmt":"2020-02-11T21:00:00","guid":{"rendered":"https:\/\/prohoster.info\/blog\/blog_prohoster\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit"},"modified":"2020-02-18T14:04:41","modified_gmt":"2020-02-18T11:04:41","slug":"besperebojniki-apc-smart-ups-i-kak-ih-gotovit","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","title":{"rendered":"UPS APC Smart UPS, dhe si t'i p\u00ebrgatisim ato","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Mes bardh\u00eb t\u00eb pasur t\u00eb UPS-ve, m\u00eb t\u00eb zakonshmit n\u00eb server\u00ebt e nivelit fillestar jan\u00eb Smart UPS nga APC (tani \u2013 Schneider Electric). Besueshm\u00ebria e shk\u00eblqyer dhe \u00e7mimi i ul\u00ebt n\u00eb tregun e dyt\u00eb e ndihmojn\u00eb q\u00eb sistem administrator\u00ebt, pa menduar shum\u00eb, t\u00eb mbushin raftet me k\u00ebto UPS dhe t\u00eb p\u00ebrpiqen t\u00eb nxjerrin maksimumin nga pajisjet e 10-15 viteve m\u00eb par\u00eb duke z\u00ebvend\u00ebsuar thjesht baterit\u00eb. Fatkeq\u00ebsisht, kjo nuk jep gjithmon\u00eb rezultatet e pritura. Le t\u00eb p\u00ebrpiqemi t\u00eb kuptojm\u00eb - \u00e7far\u00eb dhe si duhen b\u00ebr\u00eb gj\u00ebrat q\u00eb UPS juaj t\u00eb funksionoj\u00eb \"si i ri\".<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<h3>Zgjedhja e baterive<\/h3>\n<p>\nT\u00eb gjitha artikujt dhe temat n\u00eb forumet rreth zgjedhjes s\u00eb baterive p\u00ebr UPS, shpesh p\u00ebrngjasojn\u00eb me temat p\u00ebr zgjedhjen e vajit motorik p\u00ebr automjete\/motora. Le t\u00eb p\u00ebrpiqemi t\u00eb mos ngjajm\u00eb si ata, por t\u00eb kuptojm\u00eb parimet kryesore t\u00eb zgjedhjes s\u00eb baterive n\u00eb shembullin e prodhuesit CSB. <\/p>\n<p>Shohim se ata kan\u00eb nj\u00eb shum\u00ebllojshm\u00ebri t\u00eb linjave t\u00eb baterive: GP, GPL, HR, HRL, UPS, TPL. <\/p>\n<p>Fillojm\u00eb t\u00eb lexojm\u00eb: GP, GPL - bateri univerzale <b>p\u00ebr shkarkime t\u00eb vogla dhe mesatare.<\/b>. Rekomandohen p\u00ebr p\u00ebrdorim n\u00eb sistemet e siguris\u00eb dhe t\u00eb zjarrit si dhe n\u00eb UPS. Ato nuk na p\u00ebrshtaten. Edhe pse, pik\u00ebrisht ato zakonisht blihen, pa u munduar t\u00eb studiojn\u00eb karakteristikat e tyre. <\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS, dhe si t&#039;i p\u00ebrgatisim ato\" src=\"\/wp-content\/uploads\/2020\/02\/8daafaf7943d755075773d981e84d94c.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nSeria HR - bateri me kapacitet t\u00eb rritur q\u00eb lejojn\u00eb shkarkim t\u00eb thell\u00eb (deri n\u00eb 11% kapacitet t\u00eb mbetur), ve\u00e7an\u00ebrisht t\u00eb dobishme kur nevojiten shkarkime t\u00eb m\u00ebdha. Diferencimi i baterive \"H\" - \u00ebsht\u00eb nj\u00eb konstrukt i ve\u00e7ant\u00eb i rrjet\u00ebs, q\u00eb lejon t\u00eb rritet fuqia e daljes me 20%. Ato jan\u00eb m\u00eb t\u00eb p\u00ebrshtatshme p\u00ebr p\u00ebrdorim n\u00eb centralet energjetike t\u00eb fuqishme dhe n\u00eb UPS.<\/p>\n<p>Shkronja \"L\" n\u00eb seri tregon se k\u00ebto jan\u00eb bateri me jet\u00eb t\u00eb zgjatur (Long Life) n\u00eb modin e funksionimit bufer deri n\u00eb 10 vjet.<\/p>\n<p>Dhe seria UPS - \u00ebsht\u00eb nj\u00eb bateri e projektuar ve\u00e7an\u00ebrisht p\u00ebr p\u00ebrdorim n\u00eb modin e shkarkimeve t\u00eb larta p\u00ebr nj\u00eb koh\u00eb t\u00eb shkurt\u00ebr.<\/p>\n<p>Un\u00eb zgjodha gjat\u00eb koh\u00eb nd\u00ebrmjet UPS dhe HRL, por vendosa t\u00eb marr HRL. Fatkeq\u00ebsisht \u2013 p\u00ebr t\u00eb th\u00ebn\u00eb se si do t\u00eb veprojn\u00eb ato n\u00eb pun\u00eb afatgjat\u00eb, do t\u00eb mund t\u00eb flas pas 5 vjet\u00ebsh, dhe ngjashm\u00ebria e necroposting duket se nuk \u00ebsht\u00eb shum\u00eb Mir\u00ebpritur. Prandaj do ta konsiderojm\u00eb k\u00ebt\u00eb si zgjedhjen time personale dhe nuk do ta imponoj at\u00eb. Por ju duhet t\u00eb kuptoni se \u00ebsht\u00eb e nevojshme t\u00eb zgjidhni bateri me shkarkime t\u00eb larta, pasi ato duhet t\u00eb jen\u00eb n\u00eb gjendje t\u00eb japin t\u00eb gjith\u00eb kapacitetin e akumuluar p\u00ebr 20-30 minuta. <\/p>\n<h3>P\u00ebrzgjedhja e grupeve t\u00eb baterive<\/h3>\n<p>\nDuke marr\u00eb parasysh se n\u00eb nd\u00ebrtim p\u00ebrdoren disa bateri, \u00ebsht\u00eb tep\u00ebr e d\u00ebshirueshme q\u00eb ato t\u00eb ken\u00eb karakteristika t\u00eb nj\u00ebjta. P\u00ebrndryshe, nj\u00eb bateri e dob\u00ebt do t\u00eb sjell\u00eb q\u00eb e gjith\u00eb nd\u00ebrtimi t\u00eb funksionoj\u00eb krejt ndryshe nga sa pritej.<\/p>\n<p>Para rreth 5 vjet\u00ebsh, zbulova kompanin\u00eb rostoviane \u00abBastion\u00bb q\u00eb prodhon testues p\u00ebr kapacitetin e baterive me mark\u00ebn tregtare \u00abSkat\u00bb. Nuk guxoj t\u00eb pretendoj p\u00ebr sakt\u00ebsin\u00eb perfekte t\u00eb matjeve t\u00eb kapacitetit, por p\u00ebr t\u00eb vler\u00ebsuar nivelin: ideal-jeton-ingjizuar-vdek\u00ebs, ky testues \u00ebsht\u00eb m\u00eb se i mjaftuesh\u00ebm. <\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS, dhe si t&#039;i p\u00ebrgatisim ato\" src=\"\/wp-content\/uploads\/2020\/02\/7390b5c6865ebe74998c6d6494c4e548.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nN\u00eb parim, mund t\u00eb matni kapacitetin me nj\u00eb karikim-shkarkim t\u00eb thjesht\u00eb duke p\u00ebrdorur or\u00ebn, nj\u00eb llamp\u00eb makine 21W (ajo jep ngarkes\u00eb rreth 1A) dhe nj\u00eb testues, por kjo \u00ebsht\u00eb koh\u00ebzgjat\u00ebse dhe shpeshher\u00eb \u00ebsht\u00eb m\u00eb e leht\u00eb t\u00eb mos e b\u00ebsh.<\/p>\n<p>N\u00eb rastin m\u00eb ekstrem \u2013 thjesht p\u00ebrpiqemi t\u00eb vendosim bateri t\u00eb fresk\u00ebta nga nj\u00eb grupe dhe shpresojm\u00eb q\u00eb t\u00eb keni fat. <\/p>\n<h3>Elektrokimi \u00ebsht\u00eb shkenca e kontakteve.<\/h3>\n<p>\nNj\u00eb kontakt i dob\u00ebt n\u00eb nj\u00eb nd\u00ebrtim prej 4 baterish do t\u00eb anuloj\u00eb t\u00eb gjitha p\u00ebrpjekjet tuaja, prandaj duhet t\u00eb p\u00ebrballim nd\u00ebrtimin me shum\u00eb kujdes. Zakonisht n\u00eb UPS p\u00ebrdoren lidh\u00ebs p\u00ebr bateri me kap\u00ebse, t\u00eb cilat me thjesht t\u00eb t\u00ebrhequra mund t\u00eb shkat\u00ebrrohen leht\u00ebsisht. Prandaj, merrni nj\u00eb screwdriver t\u00eb vog\u00ebl, futeni n\u00eb lidh\u00ebs si n\u00eb foto dhe heqeni at\u00eb me kujdes, pa b\u00ebr\u00eb shum\u00eb p\u00ebrpjekje. Si\u00e7 sugjeroi nj\u00eb koleg n\u00eb koment \u2013 thjesht t\u00ebrhiqni p\u00ebr mbules\u00ebn plastike, dhe jo p\u00ebr kabllin. Lidh\u00ebsi hiqet me nj\u00eb klik t\u00eb leht\u00eb.<\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS, dhe si t&#039;i p\u00ebrgatisim ato\" src=\"\/wp-content\/uploads\/2020\/02\/07d704acf5b9c5a92b2ddf6e05f89f2a.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nP\u00ebrsa i p\u00ebrket lidhjes s\u00eb duhur t\u00eb kabllove, mendoj se \u00ebsht\u00eb e tep\u00ebrt t\u00eb shkruaj. N\u00ebse keni futur duar brenda UPS, \u00ebsht\u00eb e qart\u00eb se e dini parimin e lidhjes s\u00eb baterive n\u00eb seri. Dhe p\u00ebr t\u00eb tjer\u00ebt: let\u00ebr-pen\u00eb ose smartphone me kamer\u00eb. Pas p\u00ebrfundimit t\u00eb nd\u00ebrtimit, p\u00ebr ndonj\u00eb rast matni tensionin n\u00eb konstruksion me testuesin dhe krahasojeni me at\u00eb q\u00eb duhet t\u00eb jet\u00eb, bazuar n\u00eb numrin e baterive.<\/p>\n<h3>\u00abE kam b\u00ebr\u00eb gjith\u00e7ka si\u00e7 \u00ebsht\u00eb shkruar, por nuk ndihmoi\u00bb<\/h3>\n<p>\nTani e tani fillon gj\u00ebja m\u00eb interesante. UPS, gjat\u00eb funksionimit t\u00eb tij, her\u00eb pas here (zakonisht \u00e7do 7 ose 14 dit\u00eb, n\u00eb var\u00ebsi t\u00eb konfigurimit) kryen nj\u00eb kalibrim t\u00eb shkurt\u00ebr t\u00eb BAT. Ai kalon n\u00eb m\u00ebnyr\u00ebn e funksionimit nga bateria dhe mat tensionin menj\u00ebher\u00eb dhe pas nj\u00eb kohe t\u00eb vog\u00ebl. Rezultati i k\u00ebsaj \u00ebsht\u00eb nj\u00eb koeficient korrigjues i \"gjall\u00ebris\u00eb s\u00eb BAT\", i cili regjistrohet n\u00eb memorien e tij. Gjat\u00eb vdekjes s\u00eb ngadalshme t\u00eb BAT, gjendja e k\u00ebtij regjistri zvog\u00eblohet gradualisht. Bazuar n\u00eb t\u00eb, UPS llogarit koh\u00ebn e mbetur t\u00eb funksionimit nga bateria. Dhe n\u00eb nj\u00eb moment t\u00eb bukur, duke e kuptuar se gjith\u00e7ka \u00ebsht\u00eb keq, UPS ndizet treguesi q\u00eb k\u00ebrkon z\u00ebvend\u00ebsimin e BAT. Por, kur ne b\u00ebjm\u00eb z\u00ebvend\u00ebsimin, UPS nuk e di k\u00ebt\u00eb! Gjendja e regjistrit t\u00eb \"gjall\u00ebris\u00eb s\u00eb BAT\" mbetet e nj\u00ebjt\u00eb. Ne duhet ta rregullojm\u00eb at\u00eb.<\/p>\n<p>Ka dy rrug\u00eb. Rruga e par\u00eb, e thjesht\u00eb dhe e shpejt\u00eb \u2013 nevojitet nj\u00eb kalibrim i plot\u00eb i UPS. P\u00ebr k\u00ebt\u00eb, duhet ta ngarkojm\u00eb me m\u00eb shum\u00eb se 35% dhe t\u00eb nisni kalibrimin, p\u00ebr shembull nga programi PowerChute. Kjo funksionon n\u00eb rreth gjysm\u00ebn e rasteve. Pse jo gjithmon\u00eb \u2013 \u00ebsht\u00eb nj\u00eb mister i mbuluar me err\u00ebsir\u00eb. Prandaj, do t\u00eb ndjekim rrug\u00ebn e gjat\u00eb, por m\u00eb t\u00eb besueshme.<\/p>\n<p>Na nevojiten: nj\u00eb kompjuter me port COM, nj\u00eb kabllo mark\u00eb (p.sh. 940-0024C), programi UpsDiag 2.0 (p\u00ebr sigurin\u00eb e UPS tuaj, kolegu rekomandon t\u00eb p\u00ebrdorni m\u00eb mir\u00eb apcfix n\u00eb m\u00ebnyr\u00eb falas. Nuk mund t\u00eb them asgj\u00eb p\u00ebr k\u00ebt\u00eb p\u00ebrve\u00e7 se kategorikisht nuk rekomandoj n\u00eb UpsDiag t\u00eb klikoni ndonj\u00eb gj\u00eb tjet\u00ebr p\u00ebrve\u00e7 rregullimit t\u00eb regjistrit 0. <i>sidomos butonin p\u00ebr korrigjimin automatik t\u00eb gabimeve t\u00eb baterive.<\/i>) dhe <noindex><a rel=\"nofollow\" href=\"http:\/\/www.apcupsd.com\/manual\/manual.html#configuring-your-eeprom\">tabela e vlerave t\u00eb kalibrimit<\/a><\/noindex>. Na intereson vlera e regjistrit 0. N\u00eb tabel\u00eb \u00ebsht\u00eb e sh\u00ebnuar vlera p\u00ebr BAT ideale, sferike n\u00eb vakuum. \u00c7do BAT real do t\u00eb jap\u00eb pas kalibrimit nj\u00eb vler\u00eb m\u00eb t\u00eb vog\u00ebl, por jo shum\u00eb m\u00eb pak.<\/p>\n<p><img decoding=\"async\" alt=\"UPS APC Smart UPS, dhe si t&#039;i p\u00ebrgatisim ato\" src=\"\/wp-content\/uploads\/2020\/02\/93542115e332bece7803efac1c88a284.jpeg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nP\u00ebr shembull, do t\u00eb marr nj\u00eb UPS real SUA1500RMI2U. N\u00eb momentin e z\u00ebvend\u00ebsimit t\u00eb BAT, UpsDiag tregonte vler\u00ebn e regjistrit 0 \u2013 42. Pra, BAT jan\u00eb t\u00eb vdekur. Vlera e kalibrimit nga tabela \u00ebsht\u00eb A1. <\/p>\n<p>Nisim t\u00eb rregullojm\u00eb. S\u00eb pari <b>heqim kart\u00ebn rrjet nga UPS<\/b>. Prania e kart\u00ebs rrjet nuk do t'ju lejoj\u00eb t\u00eb rregulloni regjistrin. Pse \u2013 \u00ebsht\u00eb nj\u00eb pyetje p\u00ebr inxhinier\u00ebt e APC. Fatmir\u00ebsisht, ajo mund t\u00eb hiqet n\u00eb m\u00ebnyr\u00eb t\u00eb nxeht\u00eb, pa ndezur UPS. <\/p>\n<p>K\u00ebtu lidhim kabllon, hapim UpsDiag, shkojm\u00eb n\u00eb seksionin \"Kalibrimi\" dhe shikojm\u00eb gjendjen e regjistrit 0. E shkruajm\u00eb n\u00eb let\u00ebr, klikojm\u00eb me t\u00eb djatht\u00ebn mbi t\u00eb \u2013 Ndrysho. E rrisim deri n\u00eb vler\u00ebn nga tabela e vlerave kalibrues \u2013 A1. N\u00ebse n\u00eb tabel\u00eb nuk ka UPS-in tuaj, n\u00eb thelb mund ta rrisim deri n\u00eb FF. Nuk ka asgj\u00eb t\u00eb keqe prej k\u00ebsaj, p\u00ebrve\u00e7 nj\u00eb UPS-i t\u00eb habitur q\u00eb do t\u00eb tregoj\u00eb se \u00ebsht\u00eb gati t\u00eb mbaj\u00eb ngarkes\u00ebn deri n\u00eb ringjalljen e dyt\u00eb. <\/p>\n<p>Pastaj, na duhet t\u00eb presim q\u00eb bateria t\u00eb ngarkohet deri n\u00eb 100%, t\u00eb ngarkojm\u00eb UPS-in deri n\u00eb 35% ose pak m\u00eb shum\u00eb dhe t\u00eb fillojm\u00eb kalibrimin. Pas p\u00ebrfundimit t\u00eb kalibrimit, s\u00ebrish shikojm\u00eb vler\u00ebn n\u00eb regjistrin 0 dhe e krahasojm\u00eb me at\u00eb t\u00eb shkruar n\u00eb let\u00ebr. N\u00eb SUA1500RMI2U t\u00eb p\u00ebrmendur m\u00eb par\u00eb me bateri t\u00eb reja HRL1234W, vlera u b\u00eb \u2013 98, q\u00eb n\u00eb thelb nuk \u00ebsht\u00eb shum\u00eb larg vler\u00ebs kalibrues A1.<\/p>\n<p>Pasi t\u00eb mbarojm\u00eb, e l\u00ebm\u00eb p\u00ebrs\u00ebri t\u00eb ngarkohet deri n\u00eb 100%, heqim kabllon COM, e kthejm\u00eb kart\u00ebn e rrjetit dhe i d\u00ebshirojm\u00eb UPS-it nj\u00eb jet\u00eb t\u00eb gjat\u00eb dhe t\u00eb lumtur p\u00ebr mir\u00eb t\u00eb raftit ton\u00eb server.<\/p>\n<p>Meqen\u00ebse kartat e rrjetit, si AP9619, n\u00eb tregun e dyt\u00eb gjithashtu kan\u00eb r\u00ebn\u00eb n\u00eb \u00e7mime t\u00eb pap\u00ebrfillshme. Por si t\u00eb p\u00ebrgatiten (\u00ebsht\u00eb ndihma p\u00ebr riparimin e fjal\u00ebkalimeve, p\u00ebrdit\u00ebsimin e firmware-it, konfigurimin) \u2013 kjo \u00ebsht\u00eb nj\u00eb tem\u00eb p\u00ebr nj\u00eb artikull t\u00eb ve\u00e7ant\u00eb.<br \/>\n<br \/>Burimi: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/487802\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric). \u0412\u0435\u043b\u0438\u043a\u043e\u043b\u0435\u043f\u043d\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0438\u0437\u043a\u0430\u044f \u0446\u0435\u043d\u0430 \u043d\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u043c \u0440\u044b\u043d\u043a\u0435, \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u044e\u0442 \u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u0441\u0438\u0441\u0430\u0434\u043c\u0438\u043d\u044b, \u043e\u0441\u043e\u0431\u043e \u043d\u0435 \u0437\u0430\u0434\u0443\u043c\u044b\u0432\u0430\u044f\u0441\u044c, \u0443\u0442\u044b\u043a\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u043e\u0439\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u043c\u0438 \u0418\u0411\u041f \u0438 \u043f\u044b\u0442\u0430\u044e\u0442\u0441\u044f \u0432\u044b\u0442\u044f\u043d\u0443\u0442\u044c \u0441 \u0436\u0435\u043b\u0435\u0437\u043e\u043a 10-15 \u043b\u0435\u0442\u043d\u0435\u0439 \u0434\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0443\u043c \u043f\u0440\u043e\u0444\u0438\u0442\u0430 \u0431\u0430\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u043e\u0439 \u0430\u043a\u043a\u0443\u043c\u0443\u043b\u044f\u0442\u043e\u0440\u043e\u0432. \u041a \u0441\u043e\u0436\u0430\u043b\u0435\u043d\u0438\u044e \u043d\u0435 \u0432\u0441\u0435\u0433\u0434\u0430 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-56401","post","type-post","status-publish","format-standard","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2\" \/>\n\t\t<meta property=\"og:locale\" content=\"sq_AL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-02-11T21:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-02-18T11:04:41+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47B\u00ebni p\u00ebrgatisni APC Smart UPS, dhe si t'i p\u00ebrgatisni | ProHoster","description":"N\u00eb mes t\u00eb gjith\u00eb larmis\u00eb s\u00eb UPS-ve, ato m\u00eb t\u00eb zakonshmet n\u00eb serverat e nivelit fillestar jan\u00eb Smart UPS t\u00eb kompanis\u00eb APC (tani \u2013 Schneider Electric).","canonical_url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sq_AL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0411\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0438\u043a\u0438 APC Smart UPS, \u0438 \u043a\u0430\u043a \u0438\u0445 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c | ProHoster","og:description":"\u0421\u0440\u0435\u0434\u0438 \u0432\u0441\u0435\u0433\u043e \u043c\u043d\u043e\u0433\u043e\u043e\u0431\u0440\u0430\u0437\u0438\u044f \u0418\u0411\u041f, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u0432 \u0441\u0435\u0440\u0432\u0435\u0440\u043d\u044b\u0445 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0441\u0447\u0438\u0442\u0430\u044e\u0442\u0441\u044f Smart UPS \u0444\u0438\u0440\u043c\u044b APC (\u043d\u044b\u043d\u0435 \u2013 Schneider Electric).","og:url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/besperebojniki-apc-smart-ups-i-kak-ih-gotovit","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-02-11T21:00:00+00:00","article:modified_time":"2020-02-18T11:04:41+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"56401","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 19:25:39","updated":"2022-09-29 13:07:34","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/56401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/comments?post=56401"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/56401\/revisions"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media?parent=56401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/categories?post=56401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/tags?post=56401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}