{"id":71069,"date":"2020-02-23T22:07:58","date_gmt":"2020-02-23T19:07:58","guid":{"rendered":"https:\/\/prohoster.info\/blog\/chetvertushka-ethernet-a-staraya-skorost-novye-vozmozhnosti"},"modified":"2020-03-03T16:14:34","modified_gmt":"2020-03-03T13:14:34","slug":"chetvertushka-ethernet-a-staraya-skorost-novye-vozmozhnosti","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/chetvertushka-ethernet-a-staraya-skorost-novye-vozmozhnosti","title":{"rendered":"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/d10d96c9523f873599b9e858dfb50ce7.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nM\u00eb 5 shkurt t\u00eb k\u00ebtij viti u miratua nj\u00eb standard i ri p\u00ebr Ethernet me 10 megabit. Po, e lexuat sakt\u00eb: dhjet\u00eb megabit n\u00eb sekond\u00eb.<\/p>\n<p>P\u00ebr \u00e7far\u00eb i nevojitet nj\u00eb shp\u00ebrndarje aq e \"vog\u00ebl\" n\u00eb shekullin 21? P\u00ebr t\u00eb z\u00ebvend\u00ebsuar at\u00eb gung\u00eb q\u00eb e fsheh emri i gjer\u00eb \"shina fushore\" \u2014 Profibus, Modbus, CC-Link, CAN, FlexRay, HART, etj. Ka shum\u00eb dhe ato nuk jan\u00eb t\u00eb p\u00ebrputhshme me nj\u00ebra-tjetr\u00ebn dhe jan\u00eb relativisht t\u00eb komplikuara p\u00ebr t'u konfiguruar. E d\u00ebshirojm\u00eb thjesht t\u00eb fusim nj\u00eb kabll\u00eb n\u00eb nd\u00ebrprer\u00ebs, dhe mbaron. Ashtu si me Ethernet-in e zakonsh\u00ebm.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nDhe s\u00eb shpejti kjo do t\u00eb b\u00ebhet e mundur! Njoftohuni me: \"802.3cg-2019 \u2014 Standardi IEEE p\u00ebr Ethernet \u2014 Ndryshimi 5: Specifikimet e Shtres\u00ebs Fizike dhe Parametrat e Menaxhimit p\u00ebr Operimin 10 Mb\/s dhe Shp\u00ebrndarjen e Energjis\u00eb p\u00ebrmes nj\u00eb \u00c7ifti t\u00eb Balancuar t\u00eb Dijet\u00ebve.\" <\/p>\n<p>\u00c7far\u00eb e b\u00ebn k\u00ebt\u00eb Ethernet t\u00eb ri kaq interesant? Para s\u00eb gjithash \u2013 ai punon me nj\u00eb \u00e7ift t\u00eb vet\u00ebm, dhe jo me kat\u00ebr. Prandaj, ai ka m\u00eb pak lidhje dhe kabuj m\u00eb t\u00eb holl\u00eb. Dhe mund t\u00eb p\u00ebrdorni \u00e7iftin e balancuar t\u00eb instaluar tashm\u00eb, q\u00eb \u00e7on n\u00eb sensor\u00ebt dhe mekanizmat e ekzekutimit.<\/p>\n<p>Mund t\u00eb kund\u00ebrshtoni se Ethernet punon deri n\u00eb 100 metra, nd\u00ebrsa sensor\u00ebt jan\u00eb t\u00eb vendosur shum\u00eb m\u00eb larg. E v\u00ebrtet\u00eb, m\u00eb par\u00eb kjo ka qen\u00eb nj\u00eb problem. Por 802.3cg punon n\u00eb distanc\u00eb deri n\u00eb 1 km! Vet\u00ebm me nj\u00eb \u00e7ift! Nuk \u00ebsht\u00eb keq? <\/p>\n<p>N\u00eb t\u00eb v\u00ebrtet\u00eb, \u00ebsht\u00eb edhe m\u00eb mir\u00eb: p\u00ebr k\u00ebt\u00eb \u00e7ift mund t\u00eb ofrohet edhe energjia elektrike. Le ta fillojm\u00eb me k\u00ebt\u00eb.<\/p>\n<h3>IEEE 802.3bu Energjia mbi Linjat e t\u00eb Dh\u00ebnave (PoDL)<\/h3>\n<p>\nMendoj se shum\u00eb prej jush kan\u00eb d\u00ebgjuar p\u00ebr PoE (Energjia mbi Ethernet) dhe e din\u00eb se p\u00ebr t\u00eb transferuar energji nevojiten 2 \u00e7ifte telash. Hyrja\/dalja e energjis\u00eb \u00ebsht\u00eb realizuar n\u00eb piketat qendrore t\u00eb transformator\u00ebve t\u00eb \u00e7do \u00e7ifti. Duke p\u00ebrdorur nj\u00eb \u00e7ift, kjo nuk \u00ebsht\u00eb e mundur. Prandaj, duhej b\u00ebr\u00eb ndryshe. Si sakt\u00ebsisht \u2013 \u00ebsht\u00eb e treguar n\u00eb figur\u00ebn m\u00eb posht\u00eb. P\u00ebr shembull, \u00ebsht\u00eb shtuar edhe PoE klasike.<\/p>\n<p><img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/bb89378da53efb0a9bbf0a9edf583155.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nK\u00ebtu:<br \/>\nPSE \u2013 pajisja q\u00eb furnizon energjin\u00eb (burimi i energjis\u00eb)<br \/>\nPD \u2013 pajisja e fu\u00e7is\u00eb (pajisja n\u00eb an\u00ebn e larg\u00ebt, e cila konsumon elektricitet)<\/p>\n<p>Fillimisht, 802.3bu kishte 10 klas\u00eb energjie:<\/p>\n<p><img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/5d089748498a37f5ae75cc0b8629dc42.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nT\u00eb tri gradi t\u00eb tensionit t\u00eb burimit jan\u00eb t\u00eb theksuara me ngjyr\u00eb: 12, 24 dhe 48V.<\/p>\n<p>T\u00eb dh\u00ebnat:<br \/>\nVpse \u2014 tensioni i burimit t\u00eb energjis\u00eb, V<br \/>\nVpd min \u2014 tensioni minimal n\u00eb PD, V<br \/>\nI max \u2014 rrjedha maksimale n\u00eb linj\u00eb, A<br \/>\nPpd max \u2014 fuqia maksimale e konsumuar nga PD, W<\/p>\n<p>Me shfaqjen e protokollit 802.3cg jan\u00eb shtuar edhe 6 klas\u00eb t\u00eb tjera:<\/p>\n<p><img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/cb2677254d132ad27c4daf06489795ea.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nSigurisht, me nj\u00eb diversitet t\u00eb till\u00eb, PSE dhe PD duhet t\u00eb pajtohen p\u00ebr klas\u00ebn e energjis\u00eb para se t\u00eb jepet tensioni i plot\u00eb. Kjo b\u00ebhet me ndihm\u00ebn e SCCP (Serial Communications Classification Protocol). Ky \u00ebsht\u00eb nj\u00eb protokoll me shpejt\u00ebsi t\u00eb ul\u00ebt (333 bit\/s), i bazuar n\u00eb 1-Wire. Ai funksionon vet\u00ebm kur n\u00eb linj\u00eb nuk \u00ebsht\u00eb aplikuar energjia kryesore (p\u00ebrfshir\u00eb n\u00eb modalitetin gjum\u00eb).<\/p>\n<p>N\u00eb diagramin e bllokut \u00ebsht\u00eb treguar si kryhet furnizimi me energji:<\/p>\n<ul>\n<li>jepet nj\u00eb rrym\u00eb 10mA dhe kontrollohet prania e stabilitronit n\u00eb 4V n\u00eb fund<\/li>\n<li>kryhet pajtimi i klas\u00ebs s\u00eb energjis\u00eb<\/li>\n<li>aplikohet energjia kryesore<\/li>\n<li>n\u00ebse konsumimi \u00ebsht\u00eb m\u00eb pak se 10mA \u2013 aktivizohet modaliteti gjum\u00eb (aplikimi i energjis\u00eb n\u00eb gatishm\u00ebri 3.3V)<\/li>\n<li>n\u00ebse konsumimi kalon 1mA \u2013 ndodhi dalja nga modaliteti gjum\u00eb<\/li>\n<\/ul>\n<p>\n<img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/ac282970ea69804211da01c9c6a384b8.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nPajtimi i klas\u00ebs s\u00eb energjis\u00eb nuk \u00ebsht\u00eb e nevojshme t\u00eb kryhet, n\u00ebse ai \u00ebsht\u00eb i njohur paraprakisht. Ky variant quhet Fast Startup Mode. P\u00ebrdoret, p\u00ebr shembull, n\u00eb automjete, pasi atje nuk ka nevoj\u00eb t\u00eb ndryshohet konfigurimi i pajisjeve t\u00eb lidhura.<\/p>\n<p>Iniciimin e kalimit n\u00eb modalitetin gjum\u00eb mund ta b\u00ebj\u00eb ose PSE, ose PD.<\/p>\n<p>Tani do t\u00eb kalojm\u00eb n\u00eb p\u00ebrshkrimin e transferimit t\u00eb t\u00eb dh\u00ebnave. Aty ka gjithashtu interes: n\u00eb standard jan\u00eb t\u00eb definuar dy m\u00ebnyra funksionimi \u2013 p\u00ebr distanca t\u00eb gjata dhe p\u00ebr distanca t\u00eb vogla. <\/p>\n<h3>10BASE-T1L<\/h3>\n<p>\nKy \u00ebsht\u00eb nj\u00eb variant p\u00ebr distanca t\u00eb m\u00ebdha (long reach). Karakteristikat kryesore jan\u00eb si m\u00eb posht\u00eb:<\/p>\n<ul>\n<li>distanca e veprimit \u2013 deri n\u00eb 1 km<\/li>\n<li>dijet 18AWG (0.8mm2)<\/li>\n<li>deri n\u00eb 10 ndezje nd\u00ebrmjet\u00ebse (dhe dy p\u00ebrfundimtare)<\/li>\n<li>modaliteti i funksionimit pik\u00eb-n\u00eb-pik\u00eb<\/li>\n<li>dupleks i plot\u00eb<\/li>\n<li>shpejt\u00ebsia simbolike 7.5Mbod<\/li>\n<li>modulimi PAM-3, kodimi 4B3T<\/li>\n<li>sinjali me amplitud\u00eb 1V (1Vpp) ose 2.4V<\/li>\n<li>mb\u00ebshtetje p\u00ebr Ethernet Eficient Energjik (\u201cquiet\/refresh\u201d EEE)<\/li>\n<\/ul>\n<p>\nEvidentisht, ky variant \u00ebsht\u00eb i destinuar p\u00ebr p\u00ebrdorim industrial, sisteme kontrolli akses, automatizimi i nd\u00ebrtesave, ashensor\u00ebve. P\u00ebr t\u00eb menaxhuar chillers, kondicionar\u00eb, ventilator\u00eb t\u00eb vendosur n\u00eb \u00e7ati. Ose q\u00eb ndodhen n\u00eb ambiente teknike, sisteme ngrohjeje dhe pompa. Pra, ka shum\u00eb aplikime p\u00ebrve\u00e7 industris\u00eb. Pa p\u00ebrmendur internetin e gj\u00ebrave (IoT).<\/p>\n<p>Vlen t\u00eb p\u00ebrmendet se 10BASE-T1 \u00ebsht\u00eb vet\u00ebm nj\u00eb nga standartet e Single Pair Ethernet (SPE). Ka edhe 100BASE-T1 (802.3bw) dhe 1000BASE-T1 (802.3bp). E v\u00ebrteta \u00ebsht\u00eb se k\u00ebto jan\u00eb zhvilluar p\u00ebr aplikime n\u00eb automjete, prandaj distanca aty \u00ebsht\u00eb vet\u00ebm 15 metra (UTP) ose 40 metra (STP). Megjithat\u00eb, n\u00eb planet jan\u00eb edhe 100BASE-T1L me distanc\u00eb m\u00eb t\u00eb gjat\u00eb. Pra, n\u00eb t\u00eb ardhmen do t\u00eb shtohet negociimi automatik i shpejt\u00ebsis\u00eb. <\/p>\n<p>Deri tani negocimi nuk p\u00ebrdoret \u2013 \u00ebsht\u00eb shpallur \u2018fillimi i shpejt\u00eb\u2019 i interfaces: m\u00eb pak se 100ms nga furnizimi me energji deri n\u00eb fillimin e shk\u00ebmbimit t\u00eb t\u00eb dh\u00ebnave.<\/p>\n<p>Nj\u00eb opsion tjet\u00ebr (jo i detyruesh\u00ebm) \u00ebsht\u00eb rritja e amplitud\u00ebs s\u00eb transmetimit nga 1 n\u00eb 2.4V p\u00ebr t\u00eb p\u00ebrmir\u00ebsuar raportin sinjal\/z\u00ebnoise, reduktimin e numrit t\u00eb gabimeve, dhe p\u00ebrballjen me nd\u00ebrhyrjet industriale.<\/p>\n<p>Natyrisht, EEE. Ky \u00ebsht\u00eb nj\u00eb m\u00ebnyr\u00eb p\u00ebr t\u00eb kursyer energjin\u00eb elektrike duke \u00e7aktivizuar transmetuesin, n\u00ebse aktualisht nuk ka t\u00eb dh\u00ebna p\u00ebr transmetim. N\u00eb diagram tregohet se si duket kjo:<br \/>\n<img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/888029d8582e22cb5c5bb39d5f485aa9.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nNuk ka t\u00eb dh\u00ebna \u2013 d\u00ebrgojm\u00eb nj\u00eb mesazh 'un\u00eb jam duke fjetur' dhe \u00e7aktivizohemi. Her\u00eb pas here zgjohemi dhe d\u00ebrgojm\u00eb nj\u00eb mesazh 'un\u00eb jam ende k\u00ebtu'. Kur shfaqen t\u00eb dh\u00ebna, pal\u00ebs tjet\u00ebr i jepet nj\u00eb paralajm\u00ebrim 'po zgjohem' dhe fillon transmetimi. Pra, vet\u00ebm marr\u00ebsit punojn\u00eb vazhdimisht.<\/p>\n<p>Tani po shohim se \u00e7far\u00eb kan\u00eb menduar p\u00ebr variantin e dyt\u00eb t\u00eb standardit.<\/p>\n<h3>10BASE-T1S<\/h3>\n<p>\nQ\u00eb nga letra e fundit, \u00ebsht\u00eb e qart\u00eb se ky \u00ebsht\u00eb nj\u00eb protokoll p\u00ebr distanca t\u00eb shkurtra (short reach). Por p\u00ebrse \u00ebsht\u00eb e nevojshme, n\u00ebse p\u00ebr distanca t\u00eb shkurtra dhe T1L funksionon? Le t\u00eb shohim karakteristikat:<\/p>\n<ul>\n<li>distanca e veprimit deri n\u00eb 15m n\u00eb modalitetin pik\u00eb-pik\u00eb<\/li>\n<li>dupleks ose poludupleks<\/li>\n<li>d\u00ebrrasat 24-26AWG (0.2-0.13mm\u00b2)<\/li>\n<li>shpejt\u00ebsia simbolike 12.5Mbaud<\/li>\n<li>DME, kodimi 4B5B<\/li>\n<li>sinjali me amplitud\u00eb 1V (1Vpp)<\/li>\n<li>deri n\u00eb 4 lidhje nd\u00ebrmjet\u00ebse (dhe dy p\u00ebrfundimtare)<\/li>\n<li>nuk ka mb\u00ebshtetje p\u00ebr EEE<\/li>\n<\/ul>\n<p>\nNuk duket asgj\u00eb e ve\u00e7ant\u00eb. At\u00ebher\u00eb p\u00ebrse \u00ebsht\u00eb e nevojshme? Ja p\u00ebr k\u00ebt\u00eb:<\/p>\n<ul>\n<li>distanca e veprimit deri n\u00eb 25m n\u00eb modalitetin multipoint (deri n\u00eb 8 nyje)<\/li>\n<\/ul>\n<p>\nDhe p\u00ebr k\u00ebt\u00eb:<\/p>\n<ul>\n<li>modaliteti i funksionimit me parandalimin e kolizionit PLCA RS (PHY-Level Collision Avoidance Reconciliation Sublayer)<\/li>\n<\/ul>\n<p>\nDhe kjo \u00ebsht\u00eb shum\u00eb m\u00eb interesante, apo jo? Sepse ndihmon ndjesh\u00ebm p\u00ebr t\u00eb zvog\u00ebluar numrin e kabllove n\u00eb armaturat e menaxhimit, makinat, robot\u00ebt, automjetet. Dhe tashm\u00eb ka oferta p\u00ebr ta p\u00ebrdorur si z\u00ebvend\u00ebsim p\u00ebr I2C n\u00eb <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/sq\/server\/dts-gdansk\/\"   title=\"server\u00eb\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"4502\">server\u00eb<\/a>, switch-e dhe elektronika t\u00eb tjera.<\/p>\n<p><img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/98614d57cc671efc36bee4d3251f8e60.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nPor\u00eb, m\u00ebnyra multipoint ka disa disavantazhe. Nj\u00ebra prej tyre \u00ebsht\u00eb ambienti i p\u00ebrbashk\u00ebt i transmetimit t\u00eb t\u00eb dh\u00ebnave. Sigurisht, p\u00ebrplasje t\u00eb tilla zgjidhen me an\u00eb t\u00eb CSMA\/CD. Por nuk dihet se \u00e7far\u00eb vonese do t\u00eb ket\u00eb. Dhe p\u00ebr disa aplikacione, kjo \u00ebsht\u00eb kritik. Prandaj, n\u00eb standardin e ri, m\u00ebnyra multipoint \u00ebsht\u00eb plot\u00ebsuar me nj\u00eb modalitet t\u00eb ve\u00e7ant\u00eb PLCA RS (shihni seksionin e ardhsh\u00ebm).<\/p>\n<p>Disavantazhi i dyt\u00eb \u00ebsht\u00eb se PoDL nuk funksionon n\u00eb modalitetin multipoint. Kjo do t\u00eb thot\u00eb se energjia duhet t\u00eb sigurohet p\u00ebrmes nj\u00eb kablli t\u00eb ve\u00e7ant\u00eb ose t\u00eb merret nga ndonj\u00eb vend tjet\u00ebr. <\/p>\n<p>Megjithat\u00eb, n\u00eb modalitetin pik\u00eb-pik\u00eb, PoDL funksionon edhe n\u00eb T1S.<\/p>\n<h3>PLCA RS<\/h3>\n<p>\nKjo modalitet funksionon si m\u00eb posht\u00eb:<\/p>\n<ul>\n<li>nj\u00ebsit\u00eb ndajn\u00eb identifikuesit, nj\u00ebsia me ID=0 b\u00ebhet koordinatori<\/li>\n<li>koordinatori l\u00ebshon n\u00eb rrjet sinjalin BEACON, q\u00eb n\u00ebnkupton fillimin e nj\u00eb cikli t\u00eb ri transmetimi dhe d\u00ebrgon paket\u00ebn e tij t\u00eb dh\u00ebnash<\/li>\n<li>pas d\u00ebrgimit t\u00eb paket\u00ebs s\u00eb t\u00eb dh\u00ebnave, radh\u00ebs p\u00ebr transmetim kalon te nj\u00ebsia tjet\u00ebr<\/li>\n<li>n\u00ebse brenda koh\u00ebs s\u00eb nevojshme p\u00ebr transmetimin e 20 bit\u00ebve nj\u00ebsia nuk ka filluar transmetimin, radh\u00ebs kalon te nj\u00ebsia tjet\u00ebr<\/li>\n<li>kur t\u00eb gjitha nj\u00ebsit\u00eb kan\u00eb d\u00ebrguar t\u00eb dh\u00ebnat (ose e kan\u00eb l\u00ebn\u00eb radh\u00ebn e tyre), koordinatori fillon nj\u00eb cik\u00ebl t\u00eb ri<\/li>\n<\/ul>\n<p>\nN\u00eb p\u00ebrgjith\u00ebsi, kjo ngjan me TDMA. Por me ve\u00e7orin\u00eb se nyja nuk p\u00ebrdor korniz\u00ebn e saj t\u00eb koh\u00ebs n\u00ebse nuk ka \u00e7far\u00eb t\u00eb transmetoj\u00eb. Dhe p\u00ebrmasa e korniz\u00ebs nuk \u00ebsht\u00eb e p\u00ebrcaktuar strikte, pasi varet nga p\u00ebrmasa e paket\u00ebs s\u00eb t\u00eb dh\u00ebnave q\u00eb transmetohet nga nyja. T\u00eb gjitha k\u00ebto funksionojn\u00eb mbi kornizat standarde Ethernet 802.3 (PLCA RS nuk \u00ebsht\u00eb i detyruesh\u00ebm, prandaj duhet t\u00eb ket\u00eb p\u00ebrputhshm\u00ebri).<\/p>\n<p>Rezultati i p\u00ebrdorimit t\u00eb PLCA \u00ebsht\u00eb m\u00eb posht\u00eb n\u00eb grafik\u00eb. Grafiku i par\u00eb \u2013 vonesa n\u00eb var\u00ebsi t\u00eb ngarkes\u00ebs, grafiku i dyt\u00eb \u2013 kapaciteti n\u00eb var\u00ebsi t\u00eb numrit t\u00eb nyjeve transmetuese. Ka shum\u00eb qart\u00ebsi se vonesa \u00ebsht\u00eb b\u00ebr\u00eb shum\u00eb m\u00eb e parashikueshme. Dhe n\u00eb rastin m\u00eb t\u00eb keq, ajo \u00ebsht\u00eb 2 rendi m\u00eb e ul\u00ebt se n\u00eb rastin m\u00eb t\u00eb keq CSMA\/CD:<\/p>\n<p><img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/62bd8e271e7d882095281b37f63d8426.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nDhe kapaciteti i kanalit n\u00eb rastin e PLCA \u00ebsht\u00eb m\u00eb i lart\u00eb, pasi nuk harxhohet n\u00eb zgjidhjen e kolizionit:<\/p>\n<p><img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/b66a9bb8836a6d8d9aa0b21d1136f186.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h3>Konektorizime<\/h3>\n<p>\nFillimisht u zgjodh\u00ebn nga 6 opsione konectimesh, t\u00eb propozuara nga kompani t\u00eb ndryshme. Si rezultat, u ndalua tek k\u00ebto dy opsione: <\/p>\n<p><img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/0edb52b01e5d082069a10d46a57cd540.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nP\u00ebr kushte t\u00eb zakonshme p\u00ebrdorimi u zgjodh konektori LC IEC 63171-1 i kompanis\u00eb CommScope. <\/p>\n<p><img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/a4b8c60e1ffbb0008973a0c5fe1d8dca.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nP\u00ebr kushte t\u00eb ashpra p\u00ebrdorimi \u2013 familja e konektor\u00ebve IEC 63171-6 (ish 61076-3-125) e kompanis\u00eb HARTING. K\u00ebta konektor\u00eb jan\u00eb t\u00eb dizajnuar p\u00ebr nivele mbrojtjeje nga IP20 deri n\u00eb IP67.<\/p>\n<p><img decoding=\"async\" alt=\"\u00c7et\u00ebrt\u00ebshja e Ethernet-it: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja\" src=\"\/wp-content\/uploads\/2020\/02\/88150dd0f844444ab76d6c3f394658f0.jpg\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nSigurisht, lidhjet dhe kabllot mund t\u00eb jen\u00eb si UTP ashtu edhe STP. <\/p>\n<h3>T\u00eb tjera<\/h3>\n<p>\nMund t\u00eb p\u00ebrdoren kabllo Ethernet t\u00eb zakonshme me kat\u00ebr \u00e7ifte, duke p\u00ebrdorur \u00e7do \u00e7ift p\u00ebr nj\u00eb kanal t\u00eb ve\u00e7ant\u00eb SPE. K\u00ebshtu, nuk \u00ebsht\u00eb e nevojshme t\u00eb t\u00ebrheq\u00ebsh kat\u00ebr kabllo t\u00eb ve\u00e7anta n\u00eb distanca t\u00eb m\u00ebdha. Ose t\u00eb p\u00ebrdoret nj\u00eb kabllo nj\u00eb\u00e7ip, dhe n\u00eb fundin e larg\u00ebt t\u00eb vendoset nj\u00eb switch p\u00ebr Ethernet nj\u00eb\u00e7ip. <\/p>\n<p>Gjithashtu, mund t\u00eb lidhet ky switch direkt n\u00eb rrjetin lokal t\u00eb nd\u00ebrmarrjes, n\u00ebse nj\u00eb rrjet fiber optik \u00ebsht\u00eb tashm\u00eb t\u00ebrhequr n\u00eb distanca t\u00eb m\u00ebdha. Ta lidh\u00ebsh atje me sensor\u00ebt, nd\u00ebrsa t\u00eb dh\u00ebnat nga ata t\u00eb shikohen k\u00ebtu. Drejt p\u00ebr rrjetin. Pa konvertor\u00eb interfejsesh dhe porta. <\/p>\n<p>Dhe nuk \u00ebsht\u00eb domosdoshm\u00ebrisht q\u00eb t\u00eb jen\u00eb vet\u00ebm sensor\u00eb. Mund t\u00eb jen\u00eb kamera, domofona ose llamba \"inteligjente\". Pjes\u00eb t\u00eb ndonj\u00eb ventili ose kontrollor\u00ebt n\u00eb hyrje.<\/p>\n<p>K\u00ebshtu q\u00eb hapen perspektiva interesante. Sigurisht, SPE nuk do t\u00eb z\u00ebvend\u00ebsoj\u00eb t\u00eb gjitha autobar\u00ebt e fush\u00ebs. Por nj\u00eb cop\u00eb e mir\u00eb do t\u00eb marr\u00eb. N\u00eb automjete, absolutisht.<\/p>\n<p><i>PS Nuk kam gjetur tekstin e standardit n\u00eb dispozita t\u00eb hapura. Informacioni i m\u00ebsip\u00ebrm \u00ebsht\u00eb p\u00ebrmbledhur nga shum\u00eb prezantime dhe materiale t\u00eb disponueshme n\u00eb internet. Pra, n\u00eb t\u00eb mund t\u00eb ket\u00eb pasakt\u00ebsi.<\/i><br \/>\n<br \/>Burimi: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/post\/489314\/\">habr.com<\/a> <\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>5 \u0444\u0435\u0432\u0440\u0430\u043b\u044f \u044d\u0442\u043e\u0433\u043e \u0433\u043e\u0434\u0430 \u0431\u044b\u043b \u0443\u0442\u0432\u0435\u0440\u0436\u0434\u0451\u043d \u043d\u043e\u0432\u044b\u0439 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u043d\u0430 10-\u043c\u0435\u0433\u0430\u0431\u0438\u0442\u043d\u044b\u0439 Ethernet. \u0414\u0430, \u0432\u044b \u0432\u0435\u0440\u043d\u043e \u043f\u0440\u043e\u0447\u0438\u0442\u0430\u043b\u0438: \u0434\u0435\u0441\u044f\u0442\u044c \u043c\u0435\u0433\u0430\u0431\u0438\u0442 \u0432 \u0441\u0435\u043a\u0443\u043d\u0434\u0443. \u0414\u043b\u044f \u0447\u0435\u0433\u043e \u0432 21-\u043c \u0432\u0435\u043a\u0435 \u043d\u0443\u0436\u043d\u0430 \u0442\u0430\u043a\u0430\u044f \u00ab\u043c\u0430\u043b\u0435\u043d\u044c\u043a\u0430\u044f\u00bb \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c? \u0414\u043b\u044f \u0437\u0430\u043c\u0435\u043d\u044b \u0442\u043e\u0433\u043e \u0437\u043e\u043e\u043f\u0430\u0440\u043a\u0430, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0441\u043a\u0440\u044b\u0432\u0430\u0435\u0442\u0441\u044f \u043f\u043e\u0434 \u0451\u043c\u043a\u0438\u043c \u043d\u0430\u0437\u0432\u0430\u043d\u0438\u0435\u043c \u00ab\u043f\u043e\u043b\u0435\u0432\u0430\u044f \u0448\u0438\u043d\u0430\u00bb \u2014 Profibus, Modbus, CC-Link, CAN, FlexRay, HART \u0438 \u0442.\u0434. \u0418\u0445 \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u043c\u043d\u043e\u0433\u043e, \u043e\u043d\u0438 \u043d\u0435\u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u044b \u043c\u0435\u0436\u0434\u0443 \u0441\u043e\u0431\u043e\u0439 [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":71070,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-71069","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"5 \u0444\u0435\u0432\u0440\u0430\u043b\u044f \u044d\u0442\u043e\u0433\u043e \u0433\u043e\u0434\u0430 \u0431\u044b\u043b \u0443\u0442\u0432\u0435\u0440\u0436\u0434\u0451\u043d \u043d\u043e\u0432\u044b\u0439 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u043d\u0430 10-\u043c\u0435\u0433\u0430\u0431\u0438\u0442\u043d\u044b\u0439 Ethernet. \u0414\u0430, \u0432\u044b \u0432\u0435\u0440\u043d\u043e \u043f\u0440\u043e\u0447\u0438\u0442\u0430\u043b\u0438: \u0434\u0435\u0441\u044f\u0442\u044c \u043c\u0435\u0433\u0430\u0431\u0438\u0442 \u0432 \u0441\u0435\u043a\u0443\u043d\u0434\u0443. \u0414\u043b\u044f \u0447\u0435\u0433\u043e \u0432 21-\u043c \u0432\u0435\u043a\u0435 \u043d\u0443\u0436\u043d\u0430 \u0442\u0430\u043a\u0430\u044f \u00ab\u043c\u0430\u043b\u0435\u043d\u044c\u043a\u0430\u044f\u00bb \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c? \u0414\u043b\u044f \u0437\u0430\u043c\u0435\u043d\u044b \u0442\u043e\u0433\u043e \u0437\u043e\u043e\u043f\u0430\u0440\u043a\u0430, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0441\u043a\u0440\u044b\u0432\u0430\u0435\u0442\u0441\u044f \u043f\u043e\u0434 \u0451\u043c\u043a\u0438\u043c \u043d\u0430\u0437\u0432\u0430\u043d\u0438\u0435\u043c \u00ab\u043f\u043e\u043b\u0435\u0432\u0430\u044f \u0448\u0438\u043d\u0430\u00bb \u2014 Profibus, Modbus, CC-Link, CAN, FlexRay, HART \u0438 \u0442.\u0434. \u0418\u0445 \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u043c\u043d\u043e\u0433\u043e, \u043e\u043d\u0438 \u043d\u0435\u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u044b \u043c\u0435\u0436\u0434\u0443 \u0441\u043e\u0431\u043e\u0439\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/chetvertushka-ethernet-a-staraya-skorost-novye-vozmozhnosti\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"sq_AL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0427\u0435\u0442\u0432\u0435\u0440\u0442\u0443\u0448\u043a\u0430 Ethernet-\u0430: \u0441\u0442\u0430\u0440\u0430\u044f \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c, \u043d\u043e\u0432\u044b\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"5 \u0444\u0435\u0432\u0440\u0430\u043b\u044f \u044d\u0442\u043e\u0433\u043e \u0433\u043e\u0434\u0430 \u0431\u044b\u043b \u0443\u0442\u0432\u0435\u0440\u0436\u0434\u0451\u043d \u043d\u043e\u0432\u044b\u0439 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u043d\u0430 10-\u043c\u0435\u0433\u0430\u0431\u0438\u0442\u043d\u044b\u0439 Ethernet. \u0414\u0430, \u0432\u044b \u0432\u0435\u0440\u043d\u043e \u043f\u0440\u043e\u0447\u0438\u0442\u0430\u043b\u0438: \u0434\u0435\u0441\u044f\u0442\u044c \u043c\u0435\u0433\u0430\u0431\u0438\u0442 \u0432 \u0441\u0435\u043a\u0443\u043d\u0434\u0443. \u0414\u043b\u044f \u0447\u0435\u0433\u043e \u0432 21-\u043c \u0432\u0435\u043a\u0435 \u043d\u0443\u0436\u043d\u0430 \u0442\u0430\u043a\u0430\u044f \u00ab\u043c\u0430\u043b\u0435\u043d\u044c\u043a\u0430\u044f\u00bb \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c? \u0414\u043b\u044f \u0437\u0430\u043c\u0435\u043d\u044b \u0442\u043e\u0433\u043e \u0437\u043e\u043e\u043f\u0430\u0440\u043a\u0430, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0441\u043a\u0440\u044b\u0432\u0430\u0435\u0442\u0441\u044f \u043f\u043e\u0434 \u0451\u043c\u043a\u0438\u043c \u043d\u0430\u0437\u0432\u0430\u043d\u0438\u0435\u043c \u00ab\u043f\u043e\u043b\u0435\u0432\u0430\u044f \u0448\u0438\u043d\u0430\u00bb \u2014 Profibus, Modbus, CC-Link, CAN, FlexRay, HART \u0438 \u0442.\u0434. \u0418\u0445 \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u043c\u043d\u043e\u0433\u043e, \u043e\u043d\u0438 \u043d\u0435\u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u044b \u043c\u0435\u0436\u0434\u0443 \u0441\u043e\u0431\u043e\u0439\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/chetvertushka-ethernet-a-staraya-skorost-novye-vozmozhnosti\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-02-23T19:07:58+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-03-03T13:14:34+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Kat\u00ebr\u00e7ip\u00ebsi Ethernet: shpejt\u00ebsi e vjet\u00ebr, mund\u00ebsi t\u00eb reja | ProHoster","description":"M\u00eb 5 shkurt t\u00eb k\u00ebtij viti u miratua nj\u00eb standard i ri p\u00ebr Ethernet me 10 megabit. Po, e keni lexuar sakt\u00ebsisht: dhjet\u00eb megabit p\u00ebr sekond\u00eb. P\u00ebr \u00e7far\u00eb i nevojitet nj\u00eb lloj \"shpejt\u00ebsie t\u00eb vog\u00ebl\" n\u00eb shekullin e 21-t\u00eb? P\u00ebr t\u00eb z\u00ebvend\u00ebsuar at\u00eb zoodin\u00eb q\u00eb fshihet pas titullit t\u00eb gjer\u00eb \"bari i fush\u00ebs\" \u2014 Profibus, Modbus, CC-Link, CAN, FlexRay, HART etj. Jan\u00eb shum\u00eb t\u00eb shumta, dhe nuk jan\u00eb t\u00eb p\u00ebrputhshme me nj\u00ebra-tjetr\u00ebn.","canonical_url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/chetvertushka-ethernet-a-staraya-skorost-novye-vozmozhnosti","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sq_AL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0427\u0435\u0442\u0432\u0435\u0440\u0442\u0443\u0448\u043a\u0430 Ethernet-\u0430: \u0441\u0442\u0430\u0440\u0430\u044f \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c, \u043d\u043e\u0432\u044b\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 | ProHoster","og:description":"5 \u0444\u0435\u0432\u0440\u0430\u043b\u044f \u044d\u0442\u043e\u0433\u043e \u0433\u043e\u0434\u0430 \u0431\u044b\u043b \u0443\u0442\u0432\u0435\u0440\u0436\u0434\u0451\u043d \u043d\u043e\u0432\u044b\u0439 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u043d\u0430 10-\u043c\u0435\u0433\u0430\u0431\u0438\u0442\u043d\u044b\u0439 Ethernet. \u0414\u0430, \u0432\u044b \u0432\u0435\u0440\u043d\u043e \u043f\u0440\u043e\u0447\u0438\u0442\u0430\u043b\u0438: \u0434\u0435\u0441\u044f\u0442\u044c \u043c\u0435\u0433\u0430\u0431\u0438\u0442 \u0432 \u0441\u0435\u043a\u0443\u043d\u0434\u0443. \u0414\u043b\u044f \u0447\u0435\u0433\u043e \u0432 21-\u043c \u0432\u0435\u043a\u0435 \u043d\u0443\u0436\u043d\u0430 \u0442\u0430\u043a\u0430\u044f \u00ab\u043c\u0430\u043b\u0435\u043d\u044c\u043a\u0430\u044f\u00bb \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c? \u0414\u043b\u044f \u0437\u0430\u043c\u0435\u043d\u044b \u0442\u043e\u0433\u043e \u0437\u043e\u043e\u043f\u0430\u0440\u043a\u0430, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0441\u043a\u0440\u044b\u0432\u0430\u0435\u0442\u0441\u044f \u043f\u043e\u0434 \u0451\u043c\u043a\u0438\u043c \u043d\u0430\u0437\u0432\u0430\u043d\u0438\u0435\u043c \u00ab\u043f\u043e\u043b\u0435\u0432\u0430\u044f \u0448\u0438\u043d\u0430\u00bb \u2014 Profibus, Modbus, CC-Link, CAN, FlexRay, HART \u0438 \u0442.\u0434. \u0418\u0445 \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u043c\u043d\u043e\u0433\u043e, \u043e\u043d\u0438 \u043d\u0435\u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u044b \u043c\u0435\u0436\u0434\u0443 \u0441\u043e\u0431\u043e\u0439","og:url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/chetvertushka-ethernet-a-staraya-skorost-novye-vozmozhnosti","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-02-23T19:07:58+00:00","article:modified_time":"2020-03-03T13:14:34+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"71069","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 19:09:23","updated":"2022-10-03 12:45:36"},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/71069","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/comments?post=71069"}],"version-history":[{"count":1,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/71069\/revisions"}],"predecessor-version":[{"id":164380,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/71069\/revisions\/164380"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media\/71070"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media?parent=71069"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/categories?post=71069"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/tags?post=71069"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}