{"id":79649,"date":"2020-04-29T07:42:06","date_gmt":"2020-04-29T05:42:06","guid":{"rendered":"https:\/\/prohoster.info\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br"},"modified":"2020-04-29T07:42:06","modified_gmt":"2020-04-29T05:42:06","slug":"extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","title":{"rendered":"\u00abExtreme Extended Edge\u00bb, ose shk\u00ebmbimi n\u00eb baz\u00eb t\u00eb standardit IEEE 802.1BR","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Zgjidhja \u00abExtreme Extended Edge\u00bb (e njohur gjithashtu si Virtual Port Extender \u2013 VPEX) \u00ebsht\u00eb nj\u00eb teknologji e re, mb\u00ebshtetja e s\u00eb cil\u00ebs \u00ebsht\u00eb paraqitur p\u00ebr her\u00eb t\u00eb par\u00eb n\u00eb sistemin operativ EXOS, duke filluar nga versioni 22.5. Zgjidhja vet\u00eb bazohet n\u00eb standardin IEEE 802.1BR (Bridge Port Extension), dhe n\u00eb kuad\u00ebr t\u00eb versionit EXOS 22.5 \u00ebsht\u00eb shtuar mb\u00ebshtetje p\u00ebr linj\u00ebn e re harduerike ExtremeSwitching V400<\/p>\n<p><img decoding=\"async\" alt=\"\u00abExtreme Extended Edge\u00bb, ose shk\u00ebmbimi n\u00eb baz\u00eb t\u00eb standardit IEEE 802.1BR\" src=\"\/wp-content\/uploads\/2020\/04\/ea282e49e9957cdd295691a0d945a049.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\n\u00abVPEX Bridge\u00bb \u00ebsht\u00eb nj\u00eb kalues virtual i p\u00ebrb\u00ebr\u00eb nga komponente si \u2014 Controlling Bridge (CB) dhe Bridge Port Extender (BPE). P\u00ebr t\u00eb siguruar q\u00ebndrueshm\u00ebri, \u00ebsht\u00eb e mundur t\u00eb lidhen dy CB n\u00eb kuad\u00ebr t\u00eb nj\u00eb kaluesi virtual p\u00ebrmes teknologjis\u00eb MLAG. Dizajni i till\u00eb i kaluesit virtual i ngjan nj\u00eb kaluesi me shasi klasike ose nj\u00eb stak kaluesish. Dhe, n\u00ebse n\u00eb logjik\u00ebn e funksionimit t\u00eb \u00abControl Plane\u00bb kjo \u00ebsht\u00eb m\u00eb pak ose m\u00eb shum\u00eb e v\u00ebrtet\u00eb, funksionimi i \u00abData Plane\u00bb ndryshon mjaft radikalisht. Q\u00ebllimi i 802.1br \u00ebsht\u00eb lidhja e nj\u00eb porti t\u00eb larg\u00ebt me sh\u00ebrbimin lokal t\u00eb MAC (Media Access Control), nd\u00ebrsa ve\u00e7on trafikun e porteve t\u00eb larg\u00ebta.<\/p>\n<h4><b>Controlling Bridge<\/b><\/h4>\n<p><\/p>\n<ul>\n<li> Nj\u00eb dhe e vetmja pik\u00eb kontrolli<\/li>\n<li> T\u00eb gjitha konfigurimet b\u00ebhen lokalisht n\u00eb CB<\/li>\n<li> Mb\u00ebshtetja VPEX duhet t\u00eb aktivizohet, nevojitet rinisje p\u00ebr t\u00eb ndryshuar modin e pun\u00ebs<\/li>\n<li> CB gjithmon\u00eb \u00ebsht\u00eb sloti nr. 1<\/li>\n<li> N\u00eb k\u00ebt\u00eb versione, CB mb\u00ebshtet lidhjen e nj\u00ebkohshme deri n\u00eb 48 BPE<\/li>\n<li> Moda SV mb\u00ebshtetet n\u00eb disa platforma harduerike (momentalisht kjo \u00ebsht\u00eb X670G2 dhe X690, platforma t\u00eb tjera do t\u00eb shtohen n\u00eb p\u00ebrputhje me daljen e tyre)<\/li>\n<li> Licencat EXOS p\u00ebrdoren vet\u00ebm n\u00eb SV<\/li>\n<li> VPEX nuk k\u00ebrkon licenca t\u00eb dh\u00ebna shtes\u00eb<\/li>\n<li> Plot\u00ebsisht p\u00ebrgjegj\u00ebs p\u00ebr p\u00ebrpunimin e planar t\u00eb dh\u00ebnash dhe filtrimin e trafikut<\/li>\n<li> Ka nj\u00eb p\u00ebrfaq\u00ebsim virtual t\u00eb \u00e7do porte 'extended'<\/li>\n<\/ul>\n<p><\/p>\n<h4><b>Bridge Port Extender<\/b><\/h4>\n<p><\/p>\n<ul>\n<li> BPE pajisjet menaxhohen si slotet e \u00e7ashtit t\u00eb switch-it<\/li>\n<li> Slotet BPE kan\u00eb num\u00ebrim nga 100 deri n\u00eb 162<\/li>\n<\/ul>\n<p><\/p>\n<pre><code class=\"plaintext\">Slot-1 VPEX X690-48x-2q-4c.3 # show slot\nSlots    Type                 Configured           State       Ports  Flags\n-------------------------------------------------------------------------------\nSlot-1   X690-48x-2q-4c       X690-48x-2q-4c       Operational   72   M\nSlot-100 V400-48t-10GE4       V400-48t-10GE4       Operational   52   M\nSlot-101 V400-48t-10GE4       V400-48t-10GE4       Operational   52   M\nSlot-102 V400-48t-10GE4       V400-48t-10GE4       Operational   52   M\nSlot-103 V400-48t-10GE4       V400-48t-10GE4       Operational   52   M\n<\/code><\/pre>\n<p><\/p>\n<ul>\n<li> Nuk ka nevoj\u00eb p\u00ebr lidhje konsol\u00eb ose Out-of-Band IP t\u00eb lidhur me BPE<\/li>\n<li> E gjith\u00eb konfigurimi, monitorimi, zgjidhja e problemeve, diagnostikimi b\u00ebhet p\u00ebrmes nd\u00ebrfaqes CB<\/li>\n<\/ul>\n<p><\/p>\n<pre><code class=\"plaintext\">Slot-1 VPEX X670G2-48x-4q.8 # config vlan v100 add port 100:1,100:3\n*Slot-1 VPEX X670G2-48x-4q.9 # show port 100:1-3 statistics no-refresh\nPort   Link      Tx Pkt     Tx Byte     Rx Pkt     Rx Byte  Rx Pkt   Tx Pkt\n       State      Count       Count      Count       Count   Mcast    Mcast\n====== ===== ========== =========== ========== =========== ======= ========\n100:1  A     2126523437 &gt;9999999999          0           0       0    14383\n100:2  R              0           0          0           0       0        0\n100:3  A          21824     4759804 2126738453 &gt;9999999999       0    14383\n====== ===== ========== =========== ========== =========== ======= ========\n<\/code><\/pre>\n<p><\/p>\n<ul>\n<li> BPE nuk kryejn\u00eb bashk\u00ebngjitje lokale. Si rezultat, t\u00ebr\u00eb trafiku tunelohet deri n\u00eb CB dhe, n\u00ebse \u00ebsht\u00eb e nevojshme, t\u00eb b\u00ebhet p\u00ebrpara n\u00eb portin e fqinjit t\u00eb t\u00eb nj\u00ebjtit slot BPE, kthehet prapa. (BPE merr paket\u00ebn, shton titullin E-TAG dhe e d\u00ebrgon n\u00eb portin upstream)<\/li>\n<\/ul>\n<p>\nP\u00ebr t\u00eb punuar si BPE, \u00ebsht\u00eb prezantuar platforma e re harduerike ExtremeSwitching V400. Ajo p\u00ebrfshin zgjerues portash me 24\/48 porte 10\/100\/1000 Base-T me mb\u00ebshtetje PoE ose pa t\u00eb. N\u00eb modelet me 24 porta jan\u00eb dy porta 10G, nd\u00ebrsa n\u00eb ato me 48 porta kat\u00ebr porta 10G.<\/p>\n<p><img decoding=\"async\" alt=\"\u00abExtreme Extended Edge\u00bb, ose shk\u00ebmbimi n\u00eb baz\u00eb t\u00eb standardit IEEE 802.1BR\" src=\"\/wp-content\/uploads\/2020\/04\/9575a2617f71bd74de9cc71a538d8a65.png\" style=\"display:block;margin: 0 auto;\" \/><\/p>\n<h4><b>Ve\u00e7orit\u00eb e funksionimit<\/b><\/h4>\n<p>\nDizajni mb\u00ebshtet topologjit\u00eb me nj\u00eb ose dy SV dhe deri n\u00eb kat\u00ebr lidhje kaskad\u00eb VRE. Portat e kaskadave mund t\u00eb bashkohen n\u00eb LAG (deri n\u00eb 4 porta p\u00ebr modelin V400-48t\/p). Stacionet fundore mund t\u00eb lidhen me vende t\u00eb ndryshme BPE duke p\u00ebrdorur LAG.<\/p>\n<p><img decoding=\"async\" alt=\"\u00abExtreme Extended Edge\u00bb, ose shk\u00ebmbimi n\u00eb baz\u00eb t\u00eb standardit IEEE 802.1BR\" src=\"\/wp-content\/uploads\/2020\/04\/0fa7476e2c1edc2a1d26705f7db3d456.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\nDetektimi dhe funksionimi i BPE bazohet n\u00eb protokolle t\u00eb tilla si:<\/p>\n<ul>\n<li> LLDP \u2013 detektimi fillestar dhe p\u00ebrcaktimi i llojit dhe mund\u00ebsive t\u00eb pajisjes s\u00eb lidhur<\/li>\n<li> ECP \u2013 \u00abEdge Control Protocol\u00bb transport p\u00ebr PE-CSP<\/li>\n<li> PE-CSP \u2013 \u00abPort Extender Control and Status Protocol\u00bb konfigurimi i kontrollit BPE me Bridge Kontrollues<\/li>\n<li> LACP \u2013 instalimi i LAG nd\u00ebrmjet porteve \u00abcascade\u00bb  \u00abupstream\u00bb<\/li>\n<\/ul>\n<p>\nN\u00ebse p\u00ebrdoret nj\u00eb dizajn i q\u00ebndruesh\u00ebm me dy SV dhe MLAG, at\u00ebher\u00eb gjat\u00eb rindezjes s\u00eb nj\u00eb CB, BPE do t\u00eb vazhdoj\u00eb t\u00eb d\u00ebrgoj\u00eb trafik p\u00ebrmes Bridge Kontrollues t\u00eb mbetur. N\u00ebse rindezhet CB i vet\u00ebm, at\u00ebher\u00eb BPE do t\u00eb \u00e7aktivizoj\u00eb administrativisht portat e saj \u00abextended\u00bb. <br \/>\nP\u00ebr leht\u00ebsimin e konfigurimit t\u00eb topologjis\u00eb me 2 SB, \u00ebsht\u00eb shtuar mund\u00ebsia e konfigurimit t\u00eb porteve MLAG t\u00eb t\u00eb dyja pirave nga cilado nga SB-t\u00eb. Rejimi quhet \"mlag orchestration\", ku pirat sinkronizojn\u00eb nj\u00eb pjes\u00eb t\u00eb konfiguracionit q\u00eb lidhet me cil\u00ebsimet e porteve MLAG. Konfigurimi i ngjan konfigurimit t\u00eb \"virtual-router\"-ve personalizuar.<\/p>\n<pre><code class=\"plaintext\">Slot-1 VPEX X670G2-48x-4q.11 # filloni orkestrimin mlag \"bottom\"\n(orkestrimi bottom) Slot-1 VPEX X670G2-48x-4q.12 # dilni\nSlot-1 VPEX X670G2-48x-4q.13 #\n<\/code><\/pre>\n<p>\nFunksionaliteti \"Controlling Bridge\" \u00ebsht\u00eb i disponuesh\u00ebm pas instalimit t\u00eb modulit falas p\u00ebr EXOS, i cili ka zgjerimin .xmod. N\u00eb t\u00eb nj\u00ebjtin modul do t\u00eb gjenden imazhe p\u00ebr p\u00ebrdit\u00ebsimet p\u00ebr BPE. K\u00ebshtu, kur SB dhe BPE zbulojn\u00eb nj\u00ebri-tjetrin, CB kontrollon versionin e firmware-it t\u00eb instaluar n\u00eb BPE dhe, n\u00ebse \u00ebsht\u00eb e nevojshme, e p\u00ebrdit\u00ebson automatikisht.<\/p>\n<p>Ve\u00e7orit\u00eb e p\u00ebrmendura m\u00eb sip\u00ebr t\u00eb funksionimit lejojn\u00eb q\u00eb nd\u00ebrrimi i slotit t\u00eb BPE-s\u00eb t\u00eb b\u00ebhet sa m\u00eb thjesht\u00eb dhe shpejt n\u00eb rast nevoje. Meqen\u00ebse BPE slotet nuk ruajn\u00eb konfigurim dhe nuk jan\u00eb lidhur n\u00eb sistem n\u00eb asnj\u00eb m\u00ebnyr\u00eb, pas nd\u00ebrrimit t\u00eb pajisjes dhe ndezjes s\u00eb energjis\u00eb, BPE do t\u00eb zbulohet nga SB dhe do t\u00eb aplikohet konfigurimi ekzistues, po ashtu, n\u00ebse \u00ebsht\u00eb e nevojshme do t\u00eb p\u00ebrdit\u00ebsohet firmware-i.<\/p>\n<p>Ky ky\u00e7je \u00ebsht\u00eb e p\u00ebrshtatshme p\u00ebr rrjetet me drejtim t\u00eb dominuesh\u00ebm t\u00eb trafikut Veri\/Jug, t\u00eb tilla si rrjetet e kampuseve, rrjetet e bizneseve n\u00eb logjistik\u00eb, edukim, qendra biznesi dhe t\u00eb tjera. Edhe nj\u00eb her\u00eb, p\u00ebrmendim se avantazhet e rrjeteve t\u00eb nd\u00ebrtuara mbi zgjidhjen \"Extreme Extended Edge\" jan\u00eb:<\/p>\n<ul>\n<li> Reduktimi i niveleve t\u00eb arkitektur\u00ebs tradicionale t\u00eb rrjetit n\u00eb aspektin e konfigurimit dhe menaxhimit<\/li>\n<li> Thjesht\u00ebsia e shkall\u00ebzimit dhe implementimit<\/li>\n<li> Nuk \u00ebsht\u00eb e nevojshme t\u00eb keni lidhje t\u00eb dedikuara t\u00eb konsol\u00ebs ose OOV Mgmt p\u00ebr slotet BRE <\/li>\n<li> Reduktimi i licencimit (n\u00ebse \u00ebsht\u00eb e nevojshme, aplikohen vet\u00ebm n\u00eb SV)<\/li>\n<li> Nj\u00eb pik\u00eb e vetme konfigurimi, monitorimi dhe zgjidhjeje t\u00eb problemeve<\/li>\n<li> Paraqitja n\u00eb NMS si nj\u00eb switch i vet\u00ebm<\/li>\n<li> Nuk ka nevoj\u00eb p\u00ebr trajnim t\u00eb m\u00ebtejsh\u00ebm dhe zgjerimin e stafit<\/li>\n<\/ul>\n<p>Burimi: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/extremenetworks\/blog\/420369\/\">habr.com<\/a> <\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5. \u0421\u0430\u043c\u043e \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043e \u043d\u0430 \u0431\u0430\u0437\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR (Bridge Port Extension), \u0438 \u0432 \u0440\u0430\u043c\u043a\u0430\u0445 \u0440\u0435\u043b\u0438\u0437\u0430 EXOS 22.5 \u0431\u044b\u043b\u0430 \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d\u0430 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043d\u043e\u0432\u043e\u0439 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u044b\u0439 \u043b\u0438\u043d\u0435\u0439\u043a\u0438 ExtremeSwitching V400 \u00abVPEX Bridge\u00bb \u044d\u0442\u043e [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":79650,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-79649","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5. \u0421\u0430\u043c\u043e \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043e \u043d\u0430 \u0431\u0430\u0437\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR (Bridge Port Extension), \u0438 \u0432 \u0440\u0430\u043c\u043a\u0430\u0445 \u0440\u0435\u043b\u0438\u0437\u0430 EXOS 22.5 \u0431\u044b\u043b\u0430 \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d\u0430 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043d\u043e\u0432\u043e\u0439 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u044b\u0439 \u043b\u0438\u043d\u0435\u0439\u043a\u0438 ExtremeSwitching V400 \u00abVPEX Bridge\u00bb \u044d\u0442\u043e\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"sq_AL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u00abExtreme Extended Edge\u00bb, \u0438\u043b\u0438 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u044f \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5. \u0421\u0430\u043c\u043e \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043e \u043d\u0430 \u0431\u0430\u0437\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR (Bridge Port Extension), \u0438 \u0432 \u0440\u0430\u043c\u043a\u0430\u0445 \u0440\u0435\u043b\u0438\u0437\u0430 EXOS 22.5 \u0431\u044b\u043b\u0430 \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d\u0430 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043d\u043e\u0432\u043e\u0439 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u044b\u0439 \u043b\u0438\u043d\u0435\u0439\u043a\u0438 ExtremeSwitching V400 \u00abVPEX Bridge\u00bb \u044d\u0442\u043e\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-04-29T05:42:06+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-04-29T05:42:06+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47\u00abExtreme Extended Edge\u00bb, ose komutimi i bazuar n\u00eb standardin IEEE 802.1BR | ProHoster","description":"Zgjidhja \u00abExtreme Extended Edge\u00bb (e njohur edhe si Virtual Port Extender \u2013 VPEX) \u00ebsht\u00eb nj\u00eb teknologji e re, mb\u00ebshtetje e s\u00eb cil\u00ebs u prezantua p\u00ebr her\u00eb t\u00eb par\u00eb n\u00eb sistemin operativ EXOS, duke filluar nga l\u00ebshimi 22.5. Zgjidhja vet\u00eb bazohet n\u00eb standardin IEEE 802.1BR (Bridge Port Extension), dhe n\u00eb kuad\u00ebr t\u00eb l\u00ebshimit EXOS 22.5 u shtua mb\u00ebshtetje p\u00ebr linj\u00ebn e re t\u00eb hardware-it ExtremeSwitching V400 \u00abVPEX Bridge\u00bb.","canonical_url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sq_AL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u00abExtreme Extended Edge\u00bb, \u0438\u043b\u0438 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u044f \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR | ProHoster","og:description":"\u0420\u0435\u0448\u0435\u043d\u0438\u0435 \u00abExtreme Extended Edge\u00bb (\u0442\u0430\u043a\u0436\u0435 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u043e\u0435 \u043a\u0430\u043a Virtual Port Extender \u2013 VPEX) \u044d\u0442\u043e \u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u043f\u0435\u0440\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 EXOS, \u043d\u0430\u0447\u0438\u043d\u0430\u044f \u0441 \u0440\u0435\u043b\u0438\u0437\u0430 22.5. \u0421\u0430\u043c\u043e \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043e \u043d\u0430 \u0431\u0430\u0437\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEEE 802.1BR (Bridge Port Extension), \u0438 \u0432 \u0440\u0430\u043c\u043a\u0430\u0445 \u0440\u0435\u043b\u0438\u0437\u0430 EXOS 22.5 \u0431\u044b\u043b\u0430 \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d\u0430 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043d\u043e\u0432\u043e\u0439 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u044b\u0439 \u043b\u0438\u043d\u0435\u0439\u043a\u0438 ExtremeSwitching V400 \u00abVPEX Bridge\u00bb \u044d\u0442\u043e","og:url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/extreme-extended-edge-ili-kommutacziya-na-osnove-standarta-ieee-802-1br","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-04-29T05:42:06+00:00","article:modified_time":"2020-04-29T05:42:06+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"79649","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 16:34:38","updated":"2022-10-05 23:27:37"},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/79649","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/comments?post=79649"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/79649\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media\/79650"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media?parent=79649"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/categories?post=79649"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/tags?post=79649"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}