{"id":79691,"date":"2020-04-29T19:42:18","date_gmt":"2020-04-29T17:42:18","guid":{"rendered":"https:\/\/prohoster.info\/blog\/administrirovanie\/pochemu-oceanstor-dorado-v6-samaya-bystraya-i-nadyozhnaya-shd"},"modified":"2020-04-29T19:42:18","modified_gmt":"2020-04-29T17:42:18","slug":"pochemu-oceanstor-dorado-v6-samaya-bystraya-i-nadyozhnaya-shd","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/pochemu-oceanstor-dorado-v6-samaya-bystraya-i-nadyozhnaya-shd","title":{"rendered":"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Ju lutem, mos nxitoni me konkludimet p\u00ebr shkak t\u00eb titullit! Ne kemi argumente t\u00eb forta n\u00eb mb\u00ebshtetje t\u00eb tij dhe i kemi paketuar sa mund\u00ebm m\u00eb kompak. Po ofrojm\u00eb p\u00ebr v\u00ebmendjen tuaj nj\u00eb postim mbi konceptin dhe parimet e funksionimit t\u00eb sistemit ton\u00eb t\u00eb ri t\u00eb ruajtjes s\u00eb t\u00eb dh\u00ebnave, lansimi i t\u00eb cilit ndodhi n\u00eb janar 2020.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/36c949c0c7099441a62597353bd084a6.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<p>Sip\u00ebr mendimit ton\u00eb, avantazhi kryesor konkurrues i familjeve t\u00eb sistemeve t\u00eb ruajtjes Dorado V6 e sigurojn\u00eb pik\u00ebrisht performanca dhe besueshm\u00ebria t\u00eb p\u00ebrmendura n\u00eb titull. Po, po, aq e thjesht\u00eb, por se p\u00ebrmes cilave zgjidhjeve dhe jo aq zgjidhjeve t\u00eb men\u00e7ura arrit\u00ebm k\u00ebt\u00eb \"thjesht\u00eb\", do t\u00eb flasim sot.<\/p>\n<p>P\u00ebr t\u00eb zbuluar m\u00eb mir\u00eb potencialin e sistemeve t\u00eb reja t\u00eb brezit, do t\u00eb flasim p\u00ebr p\u00ebrfaq\u00ebsuesit m\u00eb t\u00eb lart\u00eb t\u00eb gam\u00ebs s\u00eb modeleve (modelet 8000, 18000). N\u00ebse nuk \u00ebsht\u00eb e sh\u00ebnuar ndryshe, n\u00ebnkuptohen pik\u00ebrisht ato.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/d72f9e38b1c95ae248f4afa77fc15a8c.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Nj\u00eb fjal\u00eb p\u00ebr tregun<\/h2>\n<p>\nP\u00ebr t\u00eb kuptuar m\u00eb mir\u00eb vendin e zgjidhjeve Huawei n\u00eb treg, le t\u00eb referohemi n\u00eb nj\u00eb mas\u00eb t\u00eb provuar \u2014 \"<noindex><a rel=\"nofollow\" href=\"https:\/\/ru.wikipedia.org\/wiki\/Gartner#%D0%9C%D0%B0%D0%B3%D0%B8%D1%87%D0%B5%D1%81%D0%BA%D0%B8%D0%B9_%D0%BA%D0%B2%D0%B0%D0%B4%D1%80%D0%B0%D0%BD%D1%82\">katror\u00ebt magjik\u00eb<\/a><\/noindex>\" Gartner. Dy vjet m\u00eb par\u00eb, n\u00eb sektorin e sistemeve t\u00eb ruajtjes s\u00eb p\u00ebrgjithshme, kompania jon\u00eb hyri me siguri n\u00eb grupin e lider\u00ebve, duke u l\u00ebn\u00eb pas vet\u00ebm NetApp dhe Hewlett Packard Enterprise. Pozita e Huawei n\u00eb tregun e sistemeve t\u00eb ruajtjes SSD n\u00eb vitin 2018 ishte karakterizuar nga statusi \"pretendent\", megjithat\u00eb di\u00e7ka mungonte p\u00ebr t\u00eb arritur pozitat lider.<\/p>\n<p>N\u00eb vitin 2019 Gartner n\u00eb studimin e tij bashkoi t\u00eb dyja sektor\u00ebt e p\u00ebrmendur m\u00eb sip\u00ebr n\u00eb nj\u00eb \u2014 \"Ruajtja Kryesore\". Si rezultat, Huawei s\u00ebrish p\u00ebrfundoi n\u00eb katrorin e lider\u00ebve, pran\u00eb ofruesve si IBM, Hitachi Vantara dhe Infinidat.<\/p>\n<p>P\u00ebr plot\u00ebsin\u00eb e pamjes, le t\u00eb theksojm\u00eb se 80% e t\u00eb dh\u00ebnave p\u00ebr analiz\u00eb Gartner i mbledh n\u00eb tregun amerikan, q\u00eb \u00e7on n\u00eb nj\u00eb p\u00ebrqindje t\u00eb ndjeshme n\u00eb favor t\u00eb kompanive q\u00eb jan\u00eb mir\u00eb t\u00eb prezantuara pik\u00ebrisht n\u00eb SHBA. Nd\u00ebrkoh\u00eb, ofruesit q\u00eb orientohen drejt tregjeve evropiane dhe aziatike ndodhen n\u00eb nj\u00eb pozicion m\u00eb t\u00eb pafavorsh\u00ebm. Dhe edhe pse kjo, vitin e kaluar produktet e Huawei z\u00ebn\u00eb nj\u00eb vend t\u00eb denj\u00eb n\u00eb katrorin e sip\u00ebrm t\u00eb djatht\u00eb dhe, sipas vendimit t\u00eb Gartner, \"mund t\u00eb rekomandohet p\u00ebr p\u00ebrdorim\".<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/32e0d32a60b4e88cc7cdc8dafa1ed9d5.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>\u00c7far\u00eb \u00ebsht\u00eb e re n\u00eb Dorado V6<\/h2>\n<p>\nLinija e produkteve Dorado V6, n\u00eb ve\u00e7anti, paraqitet me sistemet e nivelit fillestar t\u00eb seris\u00eb 3000. Fillimisht t\u00eb pajisura me dy kontrollues, ato mund t\u00eb zgjaten horizontalisht deri n\u00eb 16 kontrollues, 1200 disqe dhe 192 GB cache. Gjithashtu, sistemi do t\u00eb pajiset me porte t\u00eb jashtme Fibre Channel (8 \/ 16 \/ 32 Gb\/s) dhe Ethernet (1 \/ 10 \/ 25 \/ 40 \/ 100 Gb\/s).<\/p>\n<p>Vlen t\u00eb theksohet se aktualisht po b\u00ebhet reduktimi i p\u00ebrdorimit t\u00eb protokolleve pa sukses tregtar, prandaj n\u00eb fillim ne vendos\u00ebm t'u heqim mb\u00ebshtetje p\u00ebr Fibre Channel over Ethernet (FCoE) dhe Infiniband (IB). Ato do t\u00eb shtohen n\u00eb versionet e ardhshme t\u00eb programit t\u00eb funksionimit. Mb\u00ebshtetje p\u00ebr NVMe over Fabric (NVMe-oF) \u00ebsht\u00eb e disponueshme \"nga kutia\" mbi Fibre Channel. N\u00eb versionin e ardhsh\u00ebm, i cili \u00ebsht\u00eb planifikuar p\u00ebr n\u00eb qershor, \u00ebsht\u00eb parashikuar mb\u00ebshtetja e modit NVMe over Ethernet. Nga pik\u00ebpamja jon\u00eb, grupi i lartp\u00ebrmendur do t\u00eb mbuloj\u00eb mjaft nevojat e shumic\u00ebs s\u00eb klient\u00ebve t\u00eb Huawei.<\/p>\n<p>Qasja n\u00eb skedar\u00eb n\u00eb versionin aktual t\u00eb programit t\u00eb funksionimit mungon dhe do t\u00eb shfaqet n\u00eb nj\u00eb nga p\u00ebrdit\u00ebsimet e ardhshme af\u00ebr fundit t\u00eb vitit. Zbatimi \u00ebsht\u00eb planifikuar n\u00eb nivelin natyror, nga vet\u00eb kontrolluesit me porta Ethernet, pa p\u00ebrdorimin e pajisjeve t\u00eb jashtme.<\/p>\n<p>Dallimi kryesor midis modelit Dorado V6 t\u00eb seris\u00eb 3000 dhe atyre m\u00eb t\u00eb vjetra \u00ebsht\u00eb se n\u00eb backend mb\u00ebshtet vet\u00ebm nj\u00eb protokoll \u2014 SAS 3.0. Si rezultat, dhe ruajt\u00ebsit mund t\u00eb p\u00ebrdoren vet\u00ebm me at\u00eb nd\u00ebrfaqe. Nga pik\u00ebpamja jon\u00eb, performanca q\u00eb sigurohet n\u00eb k\u00ebt\u00eb m\u00ebnyr\u00eb \u00ebsht\u00eb mjaft e mjaftueshme p\u00ebr nj\u00eb pajisje t\u00eb k\u00ebtij lloji.<\/p>\n<p>Sistemet Dorado t\u00eb serive V6 5000 dhe 6000 i p\u00ebrkasin zgjidhjeve t\u00eb mesme. Ato gjithashtu realizohen n\u00eb form\u00ebn 2U dhe jan\u00eb t\u00eb pajisura me dy kontrollues. Nga nj\u00ebra-tjetra, ato dallohen nga performanca, numri i procesor\u00ebve, numri maksimal i disqeve dhe kapaciteti i cache-it. Megjithat\u00eb, n\u00eb planin arkitektonik dhe inxhinieror, Dorado V6 5000 dhe 6000 jan\u00eb identik\u00eb dhe duken nj\u00ebsoj.<\/p>\n<p>Sistemet Dorado V6 t\u00eb serive 8000 dhe 18000 i p\u00ebrkasin klas\u00ebs hi-end. T\u00eb realizuara n\u00eb madh\u00ebsin\u00eb 4U, ato me defaut kan\u00eb nj\u00eb arkitektur\u00eb t\u00eb ndar\u00eb, n\u00eb t\u00eb cil\u00ebn kontrolluesit dhe ruajt\u00ebsit e dh\u00ebnash jan\u00eb t\u00eb ndara. N\u00eb konfigurimin minimal, ato gjithashtu mund t\u00eb pajisen me vet\u00ebm dy kontrollues, megjithat\u00eb, klient\u00ebt zakonisht k\u00ebrkojn\u00eb instalimin e kat\u00ebr ose m\u00eb shum\u00eb.<\/p>\n<p>Dorado V6 8000 shkruhet horizontalisht dhe mund t\u00eb p\u00ebrmasohet deri n\u00eb 16 kontroler\u00eb, nd\u00ebrsa Dorado V6 18000 deri n\u00eb 32. K\u00ebto sisteme jan\u00eb t\u00eb pajisura me procesor\u00eb t\u00eb ndrysh\u00ebm me numra dhe kapacitete t\u00eb ndryshme cache. Identiteti i zgjidhjeve inxhinierike mbetet i nj\u00ebjt\u00eb, ashtu si n\u00eb modelet e klas\u00ebs mid-end.<\/p>\n<p>Raftet 2U me disqe lidhen p\u00ebrmes RDMA me nj\u00eb bandwidth prej 100 Gbit\/s. Backend-i i serive m\u00eb t\u00eb larta Dorado V6 gjithashtu mb\u00ebshtet SAS 3.0, por m\u00eb tep\u00ebr p\u00ebr rastin n\u00ebse disqet SSD me k\u00ebt\u00eb nd\u00ebrfaqe do t\u00eb ulen drastikisht n\u00eb \u00e7mim. N\u00eb at\u00eb rast do t\u00eb ket\u00eb nj\u00eb justifikim ekonomik p\u00ebr p\u00ebrdorimin e tyre, pavar\u00ebsisht performanc\u00ebs m\u00eb t\u00eb ul\u00ebt. Megjithat\u00eb, momentalisht, ndryshimi n\u00eb \u00e7mim midis SSD-ve me nd\u00ebrfaqet SAS dhe NVMe \u00ebsht\u00eb aq i vog\u00ebl saq\u00eb ne nuk jemi t\u00eb gatsh\u00ebm t\u00eb rekomandojm\u00eb nj\u00eb zgjidhje t\u00eb till\u00eb.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/6006293a9dffae22770b02c616f0824e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Brenda kontrolluesit<\/h2>\n<p>\nKontrolluesit e Dorado V6 jan\u00eb realizuar n\u00eb baz\u00ebn ton\u00eb t\u00eb elementeve. Asnj\u00eb procesor nga Intel, asnj\u00eb ASIC nga Broadcom. K\u00ebshtu, t\u00eb gjitha p\u00ebrb\u00ebr\u00ebsit e mundsh\u00ebm t\u00eb pllak\u00ebs am\u00eb, po ashtu si vet\u00eb ajo, jan\u00eb plot\u00ebsisht jasht\u00eb ndikimeve t\u00eb rreziqeve q\u00eb lidhen me presionin e sanksioneve nga kompanit\u00eb amerikane. Ata q\u00eb e kan\u00eb par\u00eb ndonj\u00ebher\u00eb pajisjen ton\u00eb me syt\u00eb e tyre, me siguri kan\u00eb v\u00ebn\u00eb re shil\u00ebn me nj\u00eb vij\u00eb t\u00eb kuqe n\u00ebn logon. Ajo do t\u00eb thot\u00eb se produkti nuk ka p\u00ebrb\u00ebr\u00ebs amerikan\u00eb. Kjo \u00ebsht\u00eb politika zyrtare e Huawei - kalimi n\u00eb p\u00ebrb\u00ebr\u00ebs t\u00eb prodhuar vet\u00eb, ose n\u00eb \u00e7do rast, q\u00eb prodhohen n\u00eb vende q\u00eb nuk ndjekin politik\u00ebn e SHBA.<\/p>\n<p>K\u00ebtu \u00ebsht\u00eb \u00e7far\u00eb mund t\u00eb shihni n\u00eb pllak\u00ebn e kontrolluesit.<\/p>\n<ul>\n<li>Nj\u00eb nd\u00ebrfaqe rrjeti universale (\u00e7ipi Hisilicon 1822), e cila \u00ebsht\u00eb p\u00ebrgjegj\u00ebse p\u00ebr lidhjen me Fibre Channel ose Ethernet.<\/li>\n<li>BMC \u00e7ipi q\u00eb siguron aksesin e larg\u00ebt n\u00eb sistem, dmth. Hisilicon 1710, p\u00ebr menaxhim dhe monitorim t\u00eb plot\u00eb n\u00eb distanc\u00eb t\u00eb sistemit. T\u00eb ngjashme p\u00ebrdoren gjithashtu n\u00eb server\u00ebt tan\u00eb dhe zgjidhje t\u00eb tjera.<\/li>\n<li>Procesori qendror, i cili \u00ebsht\u00eb nj\u00eb \u00e7ip Kunpeng 920 i prodhuar nga Huawei, i nd\u00ebrtuar mbi arkitektur\u00ebn ARM. Ky \u00ebsht\u00eb i shfaqur n\u00eb diagramin e m\u00ebsip\u00ebrm, megjithat\u00eb, n\u00eb kontrollues t\u00eb tjer\u00eb mund t\u00eb instalohen modele t\u00eb ndryshme me numra dhe frekuenca t\u00eb ndryshme. Nga modeli n\u00eb model, ndryshon gjithashtu numri i procesor\u00ebve n\u00eb nj\u00eb kontrollues. P\u00ebr shembull, n\u00eb serit\u00eb m\u00eb t\u00eb larta Dorado V6, n\u00eb nj\u00eb pllak\u00eb ka kat\u00ebr.<\/li>\n<li>Kontrolluesi SSD (\u00e7ipi Hisilicon 1812e), i cili mb\u00ebshtet lidhjen si me disqet SAS ashtu edhe me ato NVMe. Shtojm\u00eb se, Huawei prodhon vet\u00eb SSD-t\u00eb, megjithat\u00eb nuk prodhon vet\u00eb qelizat NAND, duke preferuar t'i blej\u00eb ato nga kat\u00ebr prodhuesit m\u00eb t\u00eb m\u00ebdhenj n\u00eb bot\u00eb n\u00eb form\u00ebn e pllakatave t\u00eb silikonit t\u00eb pa shk\u00ebputura. Prerja, testimi dhe paketimi n\u00eb \u00e7ipa b\u00ebhet nga Huawei, pas s\u00eb cil\u00ebs i l\u00ebshon ato n\u00ebn mark\u00ebn e vet.<\/li>\n<li>\u00c7ipi i inteligjenc\u00ebs artificiale \u2014 Ascend 310. N\u00eb m\u00ebnyr\u00eb t\u00eb paracaktuar, ai nuk \u00ebsht\u00eb i pranish\u00ebm n\u00eb kontrollues dhe montohet p\u00ebrmes nj\u00eb karte t\u00eb ve\u00e7ant\u00eb, e cila z\u00eb nj\u00eb nga vendet e rezervuara p\u00ebr adaptuesit e rrjetit. \u00c7ipi p\u00ebrdoret p\u00ebr t\u00eb garantuar nj\u00eb sjellje inteligjente t\u00eb kujtes\u00ebs, p\u00ebr t\u00eb menaxhuar performanc\u00ebn ose proceset e deduplication dhe kompresionit. T\u00eb gjitha k\u00ebto detyra mund t\u00eb kryhen edhe nga procesori qendror, por \u00e7ipi i AI e b\u00ebn k\u00ebt\u00eb shum\u00eb m\u00eb efikas.<\/li>\n<\/ul>\n<p>\n<img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/5010fde2ee0cfa5ca45b21d5f590a4c6.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Ve\u00e7mas p\u00ebr procesor\u00ebt Kunpeng<\/h2>\n<p>\nProcesori Kunpeng p\u00ebrb\u00ebn nj\u00eb sistem n\u00eb nj\u00eb \u00e7ip (SoC), ku p\u00ebrve\u00e7 nj\u00ebsis\u00eb p\u00ebrpunuese, ka module hardueri q\u00eb p\u00ebrshpejtojn\u00eb procese t\u00eb ndryshme, si llogaritja e kontrolleve ose ekzekutimi i \"kodit t\u00eb fshirjes\" (erasure coding). N\u00eb t\u00eb \u00ebsht\u00eb implementuar mb\u00ebshtetje harduerike p\u00ebr SAS, Ethernet, DDR4 (nga gjasht\u00eb n\u00eb tet\u00eb kanale), etj. Kjo i lejon Huawei t\u00eb krijoj\u00eb kontrollues t\u00eb AXH, t\u00eb cil\u00ebt nuk i japin pas Intel-it n\u00eb performanc\u00eb. <\/p>\n<p>P\u00ebr m\u00eb tep\u00ebr, zgjidhjet e saj t\u00eb bazuara n\u00eb arkitektur\u00ebn ARM i japin Huawei mund\u00ebsin\u00eb t\u00eb krijoj\u00eb zgjidhje t\u00eb plota server\u00ebsh dhe t'i ofroj\u00eb ato klient\u00ebve t\u00eb saj si nj\u00eb alternativ\u00eb ndaj x86.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/0c13fba19cb159601be08bab954337cf.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Arkitektura e re Dorado V6\u2026<\/h2>\n<p>\nArkitektura e brendshme e AXH Dorado V6 t\u00eb seris\u00eb s\u00eb lart\u00eb \u00ebsht\u00eb e paraqitur nga kat\u00ebr sub-domen\u00eb kryesore (fabrika). <\/p>\n<p>Fabrika e par\u00eb \u00ebsht\u00eb frontend i p\u00ebrgjithsh\u00ebm (interfacet e rrjetit q\u00eb jan\u00eb p\u00ebrgjegj\u00ebs p\u00ebr lidhjen me fabrik\u00ebn SAN ose hostet). <\/p>\n<p>Fabrika e dyt\u00eb \u2014 nj\u00eb grup kontrolluesish, secili prej t\u00eb cil\u00ebve mund t\u00eb arrij\u00eb p\u00ebrmes protokollit RDMA si n\u00eb \u00e7do kart\u00eb rrjeti t\u00eb frontendit, ashtu edhe tek \"motor\u00ebt\" (engine), q\u00eb p\u00ebrb\u00ebn nj\u00eb kuti me kat\u00ebr kontrollues, si dhe blloqet e p\u00ebrbashk\u00ebta t\u00eb furnizimit me energji dhe ftohjes. Tani modelet Dorado V6 t\u00eb klas\u00ebs hi-end mund t\u00eb pajisen me dy \"motor\u00eb\" t\u00eb till\u00eb (p\u00ebrkat\u00ebsisht tet\u00eb kontrollues).<\/p>\n<p>Fabrika e tret\u00eb \u00ebsht\u00eb p\u00ebrgjegj\u00ebse p\u00ebr backend dhe p\u00ebrb\u00ebhet nga kartat rrjet\u00ebse RDMA 100G.<\/p>\n<p>M\u00eb n\u00eb fund, fabrika e kat\u00ebrt \"n\u00eb hardware\" paraqitet me rafte inteligjente t\u00eb nd\u00ebrlidhura me disqe.<\/p>\n<p>P\u00ebr struktura simetrike t\u00eb till\u00eb zbulon t\u00eb gjith\u00eb potencialin e teknologjis\u00eb NVMe dhe garanton performanc\u00eb t\u00eb lart\u00eb dhe besueshm\u00ebri. Procesi i hyrjes dhe daljes maksimalisht ndahen n\u00ebp\u00ebr procesor\u00eb dhe b\u00ebrtham\u00eb, duke siguruar lexime dhe shkruajta t\u00eb nj\u00ebkohshme n\u00eb shum\u00eb rrjedha.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/8317bee185aa0fb1802998dce0a69b70.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>\u2026dhe \u00e7far\u00eb na dha ajo<\/h2>\n<p>\nPerformanca maksimale e zgjidhjeve Dorado V6 \u00ebsht\u00eb rreth tri her\u00eb m\u00eb e lart\u00eb se treguesit e sistemeve t\u00eb brezit t\u00eb kaluar (t\u00eb nj\u00ebjt\u00ebs kategori) dhe mund t\u00eb arrij\u00eb deri n\u00eb 20 milion IOPS. <\/p>\n<p>Kjo \u00ebsht\u00eb p\u00ebr shkak se n\u00eb brezin e kaluar t\u00eb pajisjeve, mb\u00ebshtetje p\u00ebr NVMe ishte e pranishme vet\u00ebm n\u00eb rafte t\u00eb nd\u00ebrlidhura me disqe. Tani, ajo \u00ebsht\u00eb e pranishme n\u00eb t\u00eb gjitha fazat, nga hosti deri te SSD. Rrjeti i backend-it gjithashtu ka p\u00ebsuar ndryshime: SAS\/PCIe jan\u00eb z\u00ebvend\u00ebsuar nga RoCEv2 me kapacitet prej 100 Gbit\/s. <\/p>\n<p>Ka ndryshuar edhe vet\u00eb formati i SSD. N\u00ebse m\u00eb par\u00eb nj\u00eb rafte 2U kishte 25 disqe, tani ajo \u00ebsht\u00eb rritur n\u00eb 36 disqe me format fizik n\u00eb p\u00ebrmas\u00ebn palm-sized. P\u00ebr m\u00eb tep\u00ebr, rafte jan\u00eb \"inteligjentuar\". Tani n\u00eb \u00e7do rafte ka nj\u00eb sistem t\u00eb q\u00ebndruesh\u00ebm me dy kontroler\u00eb t\u00eb bazuar n\u00eb \u00e7ipet ARM, t\u00eb ngjashme me ato q\u00eb jan\u00eb instaluar n\u00eb kontroler\u00ebt qendror\u00eb. <\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/f109abaf3318ed2cc7831216562f0689.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nDerisa ata merren vet\u00ebm me reorganizimin e t\u00eb dh\u00ebnave, me daljen e versioneve t\u00eb reja t\u00eb programimit do t\u00eb shtohet kompresimi dhe kodimi i fshirjes, duke lejuar q\u00eb ngarkesa n\u00eb kontroler\u00ebt kryesor\u00eb t\u00eb ulet nga 15 n\u00eb 5%. Shk\u00ebmbimi i disa detyrave n\u00eb rafte gjithashtu \u00e7liron kapacitetin e rrjetit t\u00eb brendsh\u00ebm. Dhe gjith\u00eb kjo rrit ndjesh\u00ebm potencialin e shtrirjes s\u00eb sistemit.<\/p>\n<p>Kompresimi dhe deduplichimi n\u00eb SAN-in e brezit t\u00eb kaluar jan\u00eb kryer me blloqe me gjat\u00ebsi fikse. Tani \u00ebsht\u00eb shtuar nj\u00eb mod p\u00ebr t\u00eb punuar me blloqe me gjat\u00ebsi t\u00eb ndryshueshme, i cili p\u00ebr momentin duhet t\u00eb aktivizohet manualisht. Versionet e m\u00ebpasshme t\u00eb programimit ndoshta do t\u00eb ndryshojn\u00eb k\u00ebt\u00eb situat\u00eb.<\/p>\n<p>Po ashtu, shkurtimisht mbi toleranc\u00ebn ndaj d\u00ebshtimeve. Dorado V3 mbajti funksionalitetin n\u00ebse nj\u00eb kontroler nga dy e d\u00ebshton. Dorado V6 do t\u00eb siguroj\u00eb disponueshm\u00ebrin\u00eb e t\u00eb dh\u00ebnave edhe n\u00ebse d\u00ebshtojn\u00eb nj\u00ebra pas tjetr\u00ebs shtat\u00eb kontroler\u00eb nga tet\u00eb ose p\u00ebr nj\u00ebkoh\u00ebsisht kat\u00ebr nga nj\u00eb \"motor\".<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/7bc9a968883c56545ba33c2849723c37.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Besueshm\u00ebria nga k\u00ebndv\u00ebshtrimi ekonomik<\/h2>\n<p>\nS\u00eb fundmi, nd\u00ebr klient\u00ebt e Huawei u krye nj\u00eb anket\u00eb n\u00eb lidhje me at\u00eb se cilat elemente t\u00eb ve\u00e7anta t\u00eb infrastruktur\u00ebs IT kompania i konsideron t\u00eb pranueshme. N\u00eb mas\u00eb t\u00eb madhe, respondent\u00ebt e pranuan me tolerance nj\u00eb situat\u00eb hipotetike ku nj\u00eb aplikacion nuk p\u00ebrgjigjet p\u00ebr disa qindra sekonda. P\u00ebr sistemin operativ ose adaptoin e hostit, koha kritike e ndaljes rezultoi t\u00eb ishte disa dhjet\u00ebra sekonda (thell\u00ebsisht, koha e rinisjes). Dikush tregoi k\u00ebrkesa edhe m\u00eb t\u00eb larta p\u00ebr rrjetin: kapaciteti i tij i kalimit nuk duhet t\u00eb bie m\u00eb shum\u00eb se 10\u201320 sekonda. Si\u00e7 mund t\u00eb merret me mend, pjes\u00ebmarr\u00ebsit e anket\u00ebs e konsideruan si m\u00eb kritik d\u00ebshtimin e sistemeve t\u00eb ruajtjes. Nga k\u00ebndv\u00ebshtrimi i p\u00ebrfaq\u00ebsuesve t\u00eb biznesit, ndalimi i nj\u00eb sistemi ruajtjeje nuk duhet t\u00eb tejkaloj\u00eb\u2026 disa sekonda n\u00eb vit!<\/p>\n<p>Me fjal\u00eb t\u00eb tjera, n\u00ebse aplikacioni klient i bank\u00ebs nuk p\u00ebrgjigjet p\u00ebr 100 sekonda, kjo ndoshta nuk do t\u00eb sjell\u00eb pasojat katastrofike. Por, n\u00ebse po aq koh\u00eb nuk punon sistemi i ruajtjes, ndalimi i biznesit dhe humbjet financiare jan\u00eb t\u00eb mundshme.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/99bea99afab828e9341ce9227ca5434b.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<blockquote><p>N\u00eb diagramin e sip\u00ebrm jan\u00eb paraqitur shkall\u00ebt e kostos p\u00ebr or\u00ebn e pun\u00ebs p\u00ebr dhjet\u00eb bankat m\u00eb t\u00eb m\u00ebdha (t\u00eb dh\u00ebnat Forbes 2017). Pranojeni, n\u00ebse kompania juaj i afrohet p\u00ebrmasave t\u00eb bankave kineze, do t\u00eb jet\u00eb e leht\u00eb t\u00eb arsyetoni nevoj\u00ebn p\u00ebr t\u00eb bler\u00eb nj\u00eb sistem ruajtjeje p\u00ebr disa milion dollar\u00eb. E nj\u00ebjta gj\u00eb \u00ebsht\u00eb e v\u00ebrtet\u00eb e kund\u00ebrta: n\u00ebse biznesi nuk p\u00ebson humbje t\u00eb konsiderueshme gjat\u00eb ndalimit, at\u00ebher\u00eb sigurisht nuk do t\u00eb blej\u00eb nj\u00eb sistem ruajtjeje t\u00eb klas\u00ebs hi-end. N\u00eb \u00e7do rast, \u00ebsht\u00eb e r\u00ebnd\u00ebsishme t\u00eb keni nj\u00eb ide se sa do t\u00eb jet\u00eb vrima q\u00eb mund t\u00eb formohet n\u00eb portofolin tuaj, nd\u00ebrsa administratori i sistemit merret me nj\u00eb sistem ruajtjeje t\u00eb d\u00ebshtuar.<\/p><\/blockquote>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/42cbb0eec60df8471b2ed795d45e0aff.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Sekonda p\u00ebr kalimin emergjent<\/h2>\n<p>\nN\u00eb Zgjidhjen A q\u00eb ilustrohet m\u00eb lart, mund t\u00eb njihni sistemin ton\u00eb t\u00eb brezit t\u00eb kaluar Dorado V3. Kat\u00ebr kontrolluesit e saj punojn\u00eb t\u00eb \u00e7iftuar, dhe kopjet e caches ruhen vet\u00ebm n\u00eb dy kontrollues. Kontrolluesit brenda \u00e7iftit mund t\u00eb riparatojn\u00eb ngarkes\u00ebn. N\u00eb t\u00eb nj\u00ebjt\u00ebn koh\u00eb, si\u00e7 shihni, k\u00ebtu nuk ka \"fabrika\" p\u00ebr frontin dhe prapavij\u00ebn, k\u00ebshtu q\u00eb \u00e7do raft me memorie lidhet me nj\u00eb \u00e7ift t\u00eb caktuar kontrolluesish.<\/p>\n<p>N\u00eb diagramin e Zgjidhjes B \u00ebsht\u00eb paraqitur nj\u00eb zgjidhje aktuale n\u00eb treg nga nj\u00eb furnizues tjet\u00ebr (e kuptuat?). K\u00ebtu tashm\u00eb ka fabrika frontend dhe backend, nd\u00ebrsa ruajt\u00ebsit lidhen direkt me kat\u00ebr kontrollor\u00eb. Megjithat\u00eb, n\u00eb pun\u00ebn e algoritmeve t\u00eb brendshme t\u00eb sistemit ka nuanca q\u00eb nuk jan\u00eb t\u00eb dukshme n\u00eb shikim t\u00eb par\u00eb.<\/p>\n<p>N\u00eb t\u00eb djatht\u00eb \u00ebsht\u00eb paraqitur arkitektura jon\u00eb aktuale e SCSI Dorado V6 me t\u00eb gjitha element\u00ebt e saj t\u00eb brendsh\u00ebm. Le t\u00eb shqyrtojm\u00eb se si k\u00ebto sisteme e p\u00ebrballojn\u00eb nj\u00eb situat\u00eb tipike - d\u00ebshtimin e nj\u00eb kontrollori.<\/p>\n<p>N\u00eb sistemet klasike, t\u00eb cilat p\u00ebrfshijn\u00eb edhe Dorado V3, periudha q\u00eb k\u00ebrkohet p\u00ebr t\u00eb shp\u00ebrndar\u00eb ngarkes\u00ebn pas nj\u00eb d\u00ebshtimi arrin deri n\u00eb kat\u00ebr sekonda. Gjat\u00eb k\u00ebsaj kohe, hyrja-dalja ndalet plot\u00ebsisht. N\u00eb zgjidhjen Zgjidhja B nga koleg\u00ebt tan\u00eb, pavar\u00ebsisht nga arkitektura m\u00eb moderne, koha e q\u00ebndrimit pas nj\u00eb d\u00ebshtimi \u00ebsht\u00eb madje m\u00eb e gjat\u00eb - gjasht\u00eb sekonda.<\/p>\n<p>SCSI Dorado V6 e rikthen funksionimin e saj pas vet\u00ebm nj\u00eb sekonde pas d\u00ebshtimit. Ky rezultat arrihet fal\u00eb nj\u00eb ambienti t\u00eb brendsh\u00ebm homogjen RDMA, q\u00eb i lejon kontrollorit t\u00eb qaset n\u00eb memorien 'e huaj'. Nj\u00eb rrethan\u00eb tjet\u00ebr e r\u00ebnd\u00ebsishme \u00ebsht\u00eb pranija e fabrik\u00ebs frontend, q\u00eb b\u00ebn q\u00eb rruga p\u00ebr hostin t\u00eb mos ndryshoj\u00eb. Porta q\u00ebndron e nj\u00ebjt\u00eb, dhe ngarkesa thjesht d\u00ebrgohet n\u00eb kontrollor\u00ebt e sh\u00ebndetsh\u00ebm nga drejtuesit e multi-passt.<\/p>\n<p>D\u00ebshtimi i kontrollorit t\u00eb dyt\u00eb n\u00eb Dorado V6 menaxhohet p\u00ebr nj\u00eb sekond\u00eb sipas s\u00eb nj\u00ebjt\u00ebs skem\u00eb. P\u00ebr Dorado V3, kjo zgjat rreth gjasht\u00eb sekonda, nd\u00ebrsa p\u00ebr zgjidhjen e nj\u00eb furnizuesi tjet\u00ebr - n\u00ebnt\u00eb. P\u00ebr shum\u00eb DBMS, k\u00ebto intervale nuk mund t\u00eb konsiderohen t\u00eb pranueshme, pasi gjat\u00eb k\u00ebsaj kohe sistemi kalon n\u00eb modin standby dhe ndalon s\u00eb funksionuari. Kjo iu referohet s\u00eb pari DBMS-ve, q\u00eb p\u00ebrb\u00ebhen nga shum\u00eb pjes\u00eb.<\/p>\n<p>D\u00ebshtimi i kontrollorit t\u00eb tret\u00eb Solution A nuk mund t\u00eb p\u00ebrballohet. Thjesht p\u00ebr shkak se humbet aksesin n\u00eb nj\u00eb pjes\u00eb t\u00eb disk\u00ebve me t\u00eb dh\u00ebna. Nga ana tjet\u00ebr, Solution B n\u00eb nj\u00eb situat\u00eb t\u00eb till\u00eb rikthen funksionalitetin, p\u00ebr t\u00eb cilin nevojitet, si n\u00eb rastin e m\u00ebparsh\u00ebm, n\u00ebnt\u00eb sekonda.<\/p>\n<p>\u00c7far\u00eb ndodh me Dorado V6? Nj\u00eb sekond\u00eb.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/dd7e3652ce351c221dc87956ee9673e9.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>\u00c7far\u00eb mund t\u00eb b\u00ebhet brenda nj\u00eb sekonde?<\/h2>\n<p>\nGj\u00ebja kryesore \u00ebsht\u00eb q\u00eb nuk na nevojitet shum\u00eb. \u00cbsht\u00eb e r\u00ebnd\u00ebsishme t\u00eb theksojm\u00eb se n\u00eb Dorado V6 klasa hi-end fabrika e front-end-it \u00ebsht\u00eb e ndar\u00eb nga fabrika e kontroler\u00ebve. K\u00ebshtu, nuk ka porte t\u00eb ngurta q\u00eb i p\u00ebrkasin nj\u00eb kontrolluesi t\u00eb caktuar. Ri-strukturimi n\u00eb rast t\u00eb nj\u00eb d\u00ebshtimi nuk k\u00ebrkon k\u00ebrkimin e marr\u00ebveshjeve alternative ose ri-ini\u00e7ializimin e multi-passing. Sistemi vazhdon t\u00eb punoj\u00eb si\u00e7 ka punuar.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/11a653ee038856cf63937846863ae9b8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Resistenca ndaj shum\u00eb d\u00ebshtimeve<\/h2>\n<p>\nModelet m\u00eb t\u00eb avancuara t\u00eb Dorado V6, pa asnj\u00eb problem, p\u00ebrballojn\u00eb d\u00ebshtimin e p\u00ebrbashk\u00ebt t\u00eb dy kontroler\u00ebve t\u00eb \u00e7do lloji (!) nga \u00e7do \"motor\". Kjo ishte e mundur fal\u00eb faktit se tani zgjidhja ruan tri kopje t\u00eb caches. Prandaj, madje edhe n\u00eb rastin e nj\u00eb d\u00ebshtimi t\u00eb dyfisht\u00eb, gjithmon\u00eb do t\u00eb ket\u00eb nj\u00eb kopje t\u00eb pand\u00ebrprer\u00eb.<\/p>\n<p>D\u00ebshtimi sinkron i t\u00eb kat\u00ebr kontroler\u00ebve n\u00eb nj\u00eb nga \"motor\u00ebt\" gjithashtu nuk do t\u00eb shkaktoj\u00eb pasoja fatale, pasi t\u00eb tre kopjet e caches n\u00eb \u00e7do moment jan\u00eb t\u00eb shp\u00ebrndara midis \"motor\u00ebve\". Sistemi vet\u00eb monitoron p\u00ebrputhshm\u00ebrin\u00eb e k\u00ebsaj logjike pune.<\/p>\n<p>N\u00eb fund, nj\u00eb skenar krejt i papritur \u00ebsht\u00eb d\u00ebshtimi radhazi i shtat\u00eb kontroler\u00ebve nga tet\u00eb. Megjithat\u00eb, intervali minimal i lejuar p\u00ebr t\u00eb ruajtur funksionalitetin midis d\u00ebshtimeve t\u00eb ve\u00e7anta \u00ebsht\u00eb 15 minuta. Gjat\u00eb k\u00ebsaj kohe, sistemi ruajt\u00ebs do t\u00eb arrij\u00eb t\u00eb kryej\u00eb operacionet e nevojshme p\u00ebr migrimin e caches.<\/p>\n<p>Kontrolleri i mbetur do t\u00eb siguroj\u00eb operimin e ruajtjes s\u00eb t\u00eb dh\u00ebnave dhe do t\u00eb mbaj\u00eb caches p\u00ebr pes\u00eb dit\u00eb (vlera e paracaktuar, q\u00eb mund t\u00eb ndryshohet leht\u00ebsisht n\u00eb cil\u00ebsime). Pas k\u00ebsaj, caches do t\u00eb \u00e7aktivizohet, por funksionimi i sistemit do t\u00eb vazhdoj\u00eb.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/29bf3b2cd0feb5df5886a00c519c3c29.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>P\u00ebrdit\u00ebsime q\u00eb nuk shqet\u00ebsojn\u00eb<\/h2>\n<p>\nSistemi i ri operativ Dorado V6 lejon p\u00ebrdit\u00ebsimin e firmware t\u00eb sistemit ruajt\u00ebs pa rinisur kontroller\u00ebt.<\/p>\n<p>Sistemi operativ, ashtu si n\u00eb rastin e zgjidhjeve t\u00eb m\u00ebparshme, \u00ebsht\u00eb nd\u00ebrtuar n\u00eb baz\u00eb t\u00eb Linux, megjithat\u00eb shum\u00eb procese operacionale jan\u00eb transferuar nga b\u00ebrthama n\u00eb modin e p\u00ebrdoruesit. Shumica e funksioneve, p\u00ebr shembull ato q\u00eb lidhen me deduplication dhe kompresimin, tani jan\u00eb procese t\u00eb zakonshme q\u00eb funksionojn\u00eb si demon\u00eb n\u00eb sfond. Fal\u00eb k\u00ebsaj, p\u00ebr t\u00eb p\u00ebrdit\u00ebsuar modulet e ve\u00e7anta nuk \u00ebsht\u00eb e nevojshme t\u00eb nd\u00ebrroni t\u00eb gjith\u00eb sistemin operativ. P\u00ebr shembull, p\u00ebr t\u00eb shtuar mb\u00ebshtetje p\u00ebr nj\u00eb protokoll t\u00eb ri, do t\u00eb mjaftonte t\u00eb \u00e7aktivizohej moduli p\u00ebrkat\u00ebs dhe t\u00eb aktivizohej ai i ri.<\/p>\n<p>\u00cbsht\u00eb e qart\u00eb se \u00e7\u00ebshtjet e p\u00ebrdit\u00ebsimit t\u00eb sistemit vazhdojn\u00eb t\u00eb mbeten, sepse edhe n\u00eb b\u00ebrtham\u00eb mund t\u00eb ket\u00eb element\u00eb q\u00eb k\u00ebrkojn\u00eb p\u00ebrdit\u00ebsim. Por, sipas v\u00ebzhgimeve tona, ato p\u00ebrb\u00ebjn\u00eb m\u00eb pak se 6% t\u00eb numrit total. Kjo lejon t\u00eb rivendosen kontrollor\u00ebt dhjet\u00ebra her\u00eb m\u00eb rrall\u00eb se m\u00eb par\u00eb.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/4ac7ae484a2811c5550d85da0bfe13df.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Zgjidhjet e q\u00ebndrueshm\u00ebris\u00eb ndaj katastrofave dhe zgjidhjet me disponueshm\u00ebri t\u00eb lart\u00eb (HA\/DR)<\/h2>\n<p>\nDorado V6 \"nga kutia\" \u00ebsht\u00eb e gatshme p\u00ebr integrim n\u00eb zgjidhjet e shp\u00ebrndara gjeografikisht, klasteret e nivelit t\u00eb qytetit (metro) dhe qendrat e t\u00eb dh\u00ebnave \"tre her\u00eb\".<\/p>\n<p>Majtas n\u00eb ilustrimin m\u00eb sip\u00ebr \u2014 nj\u00eb metro-klaster q\u00eb \u00ebsht\u00eb i njohur p\u00ebr shumic\u00ebn. Dy SHD funksionojn\u00eb n\u00eb m\u00ebnyr\u00ebn aktive \/ aktive n\u00eb nj\u00eb distanc\u00eb deri n\u00eb 100 km nga nj\u00ebri-tjetri. Nj\u00eb infrastruktur\u00eb e till\u00eb me pranin\u00eb e nj\u00eb ose m\u00eb shum\u00eb server\u00ebve t\u00eb kuorumit mund t\u00eb mb\u00ebshtetet nga zgjidhje t\u00eb kompanive t\u00eb ndryshme, duke p\u00ebrfshir\u00eb sistemin ton\u00eb operativ n\u00eb re FusionSphere. Karakteristikat e kanalit midis sit\u00ebve b\u00ebhen t\u00eb r\u00ebnd\u00ebsishme n\u00eb k\u00ebto projekte, nd\u00ebrsa t\u00eb gjitha detyrat e tjera n\u00eb k\u00ebt\u00eb rast i merr mbi vete funksioni HyperMetro, i disponuesh\u00ebm, p\u00ebrs\u00ebri, \"nga kutia\". Mund t\u00eb b\u00ebhet integrim p\u00ebrmes Fibre Channel, si dhe p\u00ebrmes iSCSI n\u00eb rrjetet IP, n\u00ebse ka nevoj\u00eb t\u00eb till\u00eb. Nuk ka m\u00eb nevoj\u00eb p\u00ebr optik\u00eb \"t\u00eb err\u00ebt\" t\u00eb dedikuar, sepse sistemi \u00ebsht\u00eb n\u00eb gjendje t\u00eb lidhet p\u00ebrmes kanaleve ekzistuese.<\/p>\n<p>Kur nd\u00ebrtohen k\u00ebto sisteme, k\u00ebrkesa e vetme harduerike p\u00ebr SHD \u00ebsht\u00eb rezervimi i porteve p\u00ebr replikim. Mjafton t\u00eb blini nj\u00eb licenc\u00eb, t\u00eb nisni server\u00ebt e kuorumit \u2014 fizik ose virtual \u2014 dhe t\u00eb siguroheni p\u00ebr lidhje IP me kontrollor\u00ebt (10 Mbit\/s, 50 ms).<\/p>\n<p>Kjo arkitektur\u00eb leht\u00eb transferohet n\u00eb nj\u00eb sistem me tre QENDRA t\u00eb T\u00cb DHENAVE (shih pjes\u00ebn e djatht\u00eb t\u00eb ilustrimit). P\u00ebr shembull, kur dy QENDRA t\u00eb T\u00cb DHENAVE punojn\u00eb n\u00eb m\u00ebnyr\u00ebn e metro-klasterit, dhe nj\u00eb vendndodhje e tret\u00eb, e vendosur n\u00eb nj\u00eb distanc\u00eb m\u00eb t\u00eb madhe se 100 km, p\u00ebrdor replikimin asinkron.<\/p>\n<p>Sistemi teknologjikisht mb\u00ebshtet skenar\u00eb t\u00eb ndrysh\u00ebm biznesi, t\u00eb cilat do t\u00eb realizohen n\u00eb rast t\u00eb nj\u00eb eksesi masiv.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/52312571067502aa5aa1d34674dfa8de.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Mund\u00ebsia e mbijetes\u00ebs s\u00eb metro-klasterit n\u00eb rast t\u00eb disa d\u00ebshtimeve<\/h2>\n<p>\nN\u00eb ilustrimin m\u00eb sip\u00ebr dhe m\u00eb posht\u00eb gjithashtu shihet nj\u00eb metro-klaster klasik, q\u00eb p\u00ebrb\u00ebhet nga dy SHD dhe nj\u00eb server kuorum. Si\u00e7 e shihni, n\u00eb gjasht\u00eb nga n\u00ebnt\u00eb skenar\u00ebt e mundsh\u00ebm t\u00eb d\u00ebshtimeve t\u00eb shumta, infrastruktura jon\u00eb do t\u00eb ruaj\u00eb funksionalitetin.<\/p>\n<p>P\u00ebr shembull, n\u00eb skenarin e dyt\u00eb, n\u00eb rastin e d\u00ebshtimit t\u00eb serverit t\u00eb kuorumit dhe sinkronizimit midis platformave, sistemi mbetet funksional, pasi platforma e dyt\u00eb ndalon pun\u00ebn. Nj\u00eb sjellje e till\u00eb \u00ebsht\u00eb e inkorporuar n\u00eb algoritmet e nd\u00ebrtuara.<\/p>\n<p>Edhe pas tre d\u00ebshtimeve, qasja n\u00eb informacion mund t\u00eb ruhet, n\u00ebse intervali midis tyre \u00ebsht\u00eb t\u00eb pakt\u00ebn 15 sekonda.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/1b14cf534dfa60e0e771c2565ebf0d35.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Asesi zakonsh\u00ebm i n\u00ebntok\u00ebs<\/h2>\n<p>\nKujtojm\u00eb se Huawei prodhon jo vet\u00ebm SXD, por edhe nj\u00eb gam\u00eb t\u00eb plot\u00eb t\u00eb pajisjeve rrjet. \u00c7far\u00ebdo q\u00eb t\u00eb jet\u00eb ofruesi i SXD-s\u00eb q\u00eb zgjidhni, n\u00ebse midis platformave p\u00ebrdoret nj\u00eb rrjet WDM, n\u00eb 90% t\u00eb rasteve ai do t\u00eb nd\u00ebrtohet mbi zgjidhjet e kompanis\u00eb son\u00eb. Shpesh lind pyetja logjike: pse t\u00eb grumbullojm\u00eb nj\u00eb zvarrit\u00ebs sistemi, kur t\u00eb gjith\u00eb \u2018harduerin\u2019 q\u00eb \u00ebsht\u00eb plot\u00ebsisht i kompatibil \u00ebsht\u00eb n\u00eb dispozicion nga nj\u00eb ofrues?<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/7b327879c217f00fc1799df0aae6be9b.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>P\u00ebrsa i p\u00ebrket performanc\u00ebs<\/h2>\n<p>\nNdoshta nuk ka nevoj\u00eb t\u00eb bindim ask\u00ebnd m\u00eb se kalimi n\u00eb SXD All-Flash lejon t\u00eb reduktohen ndjesh\u00ebm shpenzimet p\u00ebr mir\u00ebmbajtjen e infrastruktur\u00ebs, pasi t\u00eb gjitha operacionet rutin\u00eb kryhen shum\u00eb m\u00eb shpejt. T\u00eb gjith\u00eb ofruesit e pajisjeve t\u00eb k\u00ebtij lloji e d\u00ebshmojn\u00eb k\u00ebt\u00eb. Megjithat\u00eb, shum\u00eb ofrues fillojn\u00eb t\u00eb manipullojn\u00eb kur flitet p\u00ebr r\u00ebnien e performanc\u00ebs kur aktivizohen moda t\u00eb ndryshme t\u00eb funksionimit t\u00eb SXD-s\u00eb.<\/p>\n<p>N\u00eb industrin\u00eb ton\u00eb, praktikisht \u00ebsht\u00eb e zakonshme t\u00eb jepen SXD p\u00ebr testim p\u00ebr nj\u00eb ose dy dit\u00eb. Ofruesi fillon nj\u00eb test 20-minut\u00ebsh n\u00eb nj\u00eb sistem t\u00eb zbraz\u00ebt, duke marr\u00eb tregues t\u00eb jasht\u00ebzakonsh\u00ebm t\u00eb performanc\u00ebs. Nd\u00ebrsa n\u00eb shfryt\u00ebzim t\u00eb v\u00ebrtet\u00eb, dalin shpejt \u2018kambanat e n\u00ebnshkrimit\u2019. Pas nj\u00eb dite, vlerat e bukura t\u00eb IOPS zvog\u00eblohen dyfih dhe trefish, dhe n\u00ebse SXD mbushet deri n\u00eb 80%, ato b\u00ebhen edhe m\u00eb t\u00eb ulta. Aktivizimi i RAID 5 n\u00eb vend t\u00eb RAID 10 humb edhe 10-15%, dhe n\u00eb modalitetin e metro-kllasterit performanca reduktohet gjithashtu p\u00ebr gjysm\u00eb.<\/p>\n<p>Gjith\u00e7ka q\u00eb u p\u00ebrmend m\u00eb par\u00eb, nuk ka t\u00eb b\u00ebj\u00eb me Dorado V6. Klient\u00ebt tan\u00eb kan\u00eb mund\u00ebsin\u00eb t\u00eb fillojn\u00eb nj\u00eb test t\u00eb performanc\u00ebs p\u00ebr fundjav\u00eb ose t\u00eb pakt\u00ebn p\u00ebr nj\u00eb nat\u00eb. At\u00ebher\u00eb dalin n\u00eb pah mbledhjet e mbeturinave dhe b\u00ebhet e qart\u00eb si aktivizimi i opsioneve t\u00eb ndryshme \u2014 si\u00e7 jan\u00eb snapshot-et dhe replikimi \u2014 ndikon n\u00eb vler\u00ebn e arritshme t\u00eb IOPS.<\/p>\n<p>N\u00eb Dorado V6, snapshot-et dhe RAID me paritet praktikisht nuk nd\u5f71\u54cdojn\u00eb performanc\u00ebn (3\u20135% n\u00eb vend t\u00eb 10-15%). Pro\u00e7esi i mbledhjes s\u00eb mbetjeve (mbushja e qelizave t\u00eb ruajtjes me zero), kompresimi, dhe deduplikimi n\u00eb SAN t\u00eb mbushur n\u00eb 80% gjithmon\u00eb do t\u00eb ndikojn\u00eb n\u00eb shpejt\u00ebsin\u00eb e p\u00ebrgjithshme t\u00eb p\u00ebrpunimit t\u00eb k\u00ebrkesave. Por Dorado V6 \u00ebsht\u00eb interesante sepse, \u00e7far\u00ebdo kombinimi t\u00eb funksioneve dhe mekanizmave mbrojt\u00ebs q\u00eb aktivizoni, performanca p\u00ebrfundimtare e SAN nuk do t\u00eb bjer\u00eb n\u00ebn 80% t\u00eb treguesit t\u00eb arritur pa ngarkes\u00eb.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/b4aebc1ed40e0ff68927984783d55234.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Balancimi i ngarkes\u00ebs<\/h2>\n<p>\nPerformanca e lart\u00eb e Dorado V6 arrihet p\u00ebrmes balansimit n\u00eb \u00e7do hap, konkretisht:<\/p>\n<ul>\n<li>multipassimit;<\/li>\n<li>p\u00ebrdorim t\u00eb disa lidhjeve nga nj\u00eb host;<\/li>\n<li>prania e nj\u00eb fabrike frontend;<\/li>\n<li>ndarjes s\u00eb pun\u00ebs s\u00eb kontrolluesve t\u00eb SAN;<\/li>\n<li>distribuimit t\u00eb ngarkes\u00ebs n\u00eb t\u00eb gjith\u00eb ruajt\u00ebsit n\u00eb nivelin RAID 2.0+.<\/li>\n<\/ul>\n<p>\nN\u00eb parim, kjo \u00ebsht\u00eb nj\u00eb praktik\u00eb e zakonshme. Sot, pak njer\u00ebz mbajn\u00eb t\u00eb gjitha t\u00eb dh\u00ebnat n\u00eb nj\u00eb LUN: t\u00eb gjith\u00eb p\u00ebrpiqen t\u00eb ken\u00eb, le t\u00eb thon\u00eb, tet\u00eb, ose dyzet, dhe ndoshta edhe m\u00eb shum\u00eb. Ky \u00ebsht\u00eb nj\u00eb qasje e qart\u00eb dhe e duhur, q\u00eb ne e p\u00ebrkrahim. Por n\u00ebse detyra juaj k\u00ebrkon vet\u00ebm nj\u00eb LUN, q\u00eb \u00ebsht\u00eb m\u00eb e leht\u00eb p\u00ebr t'u menaxhuar, zgjidhjet tona arkitekturore lejojn\u00eb t\u00eb arrijm\u00eb performanc\u00ebn 80% t\u00eb disponueshme kur p\u00ebrdoren disa LUN.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/f37737185e2058af5af30f79771ba6c8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Planifikimi dinamik i ngarkes\u00ebs s\u00eb procesor\u00ebve<\/h2>\n<p>\nDistribuimi i ngarkes\u00ebs n\u00eb procesor\u00eb kur p\u00ebrdoret nj\u00eb LUN \u00ebsht\u00eb realizuar si m\u00eb posht\u00eb: detyrat akoma n\u00eb nivelin e LUN ndahen n\u00eb 'shard' t\u00eb vogla, secila e caktuar n\u00eb m\u00ebnyr\u00eb t\u00eb fort\u00eb p\u00ebr kontrollues t\u00eb ve\u00e7ant\u00eb n\u00eb 'motor'. Kjo \u00ebsht\u00eb b\u00ebr\u00eb p\u00ebr t\u00eb siguruar q\u00eb sistemi t\u00eb mos humbas\u00eb performanc\u00ebn, nd\u00ebrsa 'k\u00ebrcen' me k\u00ebt\u00eb cop\u00eb t\u00eb dh\u00ebnash nd\u00ebrmjet kontrolluesve t\u00eb ndrysh\u00ebm. <\/p>\n<p>Nj\u00eb mekaniz\u00ebm tjet\u00ebr p\u00ebr ruajtjen e performanc\u00ebs s\u00eb lart\u00eb \u00ebsht\u00eb planifikimi dinamik, ku disa b\u00ebrthama t\u00eb procesor\u00ebve mund t\u00eb ndahen p\u00ebr grupe t\u00eb ndryshme detyrash. P\u00ebr shembull, n\u00ebse sistemi aktualisht \u00ebsht\u00eb n\u00eb pritje n\u00eb nivelin e deduplikimit dhe kompresimit, nj\u00eb pjes\u00eb e b\u00ebrthamave mund t\u00eb aktivizohet n\u00eb procesin e sh\u00ebrbimit t\u00eb hyrje-daljeve. Ose anasjelltas. T\u00eb gjitha k\u00ebto kryhen automatikisht dhe n\u00eb m\u00ebnyr\u00eb transparente p\u00ebr p\u00ebrdoruesin. <\/p>\n<p>T\u00eb dh\u00ebnat mbi ngarkes\u00ebn aktuale t\u00eb secilit nga b\u00ebrthamat Dorado V6 nuk shfaqen n\u00eb nd\u00ebrfaqen grafike, por p\u00ebrmes komand\u00ebs mund t\u00eb aksesoni sistemin operativ t\u00eb kontrolluesit dhe t\u00eb p\u00ebrdorni komand\u00ebn e zakonshme linux. <i>top<\/i>.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/5d6a8323e011f072c3208fdff6dc9bf3.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Mb\u00ebshtetje p\u00ebr NVMe dhe RoCE<\/h2>\n<p>\nSi\u00e7 \u00ebsht\u00eb p\u00ebrmendur tashm\u00eb, n\u00eb k\u00ebt\u00eb moment Dorado V6 mb\u00ebshtet plot\u00ebsisht NVMe mbi Fibre Channel \u00abnga kutia\u00bb dhe nuk k\u00ebrkon asnj\u00eb licenc\u00eb. N\u00eb mes t\u00eb vitit do t\u00eb shfaqet mb\u00ebshtetje p\u00ebr modalitetin NVMe mbi Ethernet. P\u00ebr ta p\u00ebrdorur at\u00eb n\u00eb m\u00ebnyr\u00eb efektive, do t\u00eb nevojitet mb\u00ebshtetje Ethernet me qasje t\u00eb drejtp\u00ebrdrejt\u00eb n\u00eb kujtes\u00eb (DMA) versioni v2.0 si nga vet\u00eb SCSI, ashtu edhe nga switch-et dhe adaptori t\u00eb rrjetit. P\u00ebr shembull, si\u00e7 jan\u00eb Mellanox ConnectX-4 ose ConnectX-5. Mund t\u00eb p\u00ebrdoren edhe kartat e rrjetit t\u00eb bazuara n\u00eb \u00e7ipet tona. Po ashtu, mb\u00ebshtetja RoCE duhet t\u00eb realizohet n\u00eb nivelin e sistemit operativ.<\/p>\n<blockquote><p>N\u00eb p\u00ebrgjith\u00ebsi, ne e konsiderojm\u00eb Dorado V6 si nj\u00eb sistem t\u00eb orientuar drejt NVMe. Pavar\u00ebsisht nga mb\u00ebshtetja ekzistuese p\u00ebr Fibre Channel dhe iSCSI, planifikohet kalimi n\u00eb Ethernet me shpejt\u00ebsi t\u00eb lart\u00eb me RDMA n\u00eb t\u00eb ardhmen.<\/p><\/blockquote>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/af643f09725ff4aa36fe4650dd9186b9.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<\/p>\n<h2>Nj\u00eb shkas marketingu<\/h2>\n<p>\nDuke pasur parasysh se sistemi Dorado V6 ka nj\u00eb q\u00ebndrueshm\u00ebri t\u00eb lart\u00eb ndaj gabimeve, shkall\u00ebzohet mir\u00eb horizontalisht, mb\u00ebshtet teknologji t\u00eb ndryshme migrimi etj., efekti ekonomik i blerjes s\u00eb tij shfaqet me fillimin e shfryt\u00ebzimit intensiv t\u00eb SCSI. Ne do t\u00eb p\u00ebrpiqemi t\u00eb vazhdojm\u00eb ta b\u00ebjm\u00eb zot\u00ebrimin e sistemit sa m\u00eb fitimprur\u00ebs, edhe n\u00ebse n\u00eb fillim kjo nuk vihet re.<\/p>\n<p>N\u00eb ve\u00e7anti, ne kemi formuar programin FLASH EVER, i lidhur me zgjatjen e ciklit t\u00eb jet\u00ebs s\u00eb SCSI dhe i destinuar p\u00ebr t\u00eb leht\u00ebsuar sa m\u00eb shum\u00eb klientin gjat\u00eb p\u00ebrmir\u00ebsimeve.<\/p>\n<p><img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/816da462a6ddefca4e40ecc3dc73cab5.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nKy program p\u00ebrfshin nj\u00eb s\u00ebr\u00eb masash:<\/p>\n<ul>\n<li>mund\u00ebsia e z\u00ebvend\u00ebsimit gradual t\u00eb kontrolluesve dhe raft\u00ebve me disqe me versionet e reja pa z\u00ebvend\u00ebsuar t\u00ebr\u00eb pajisjen (p\u00ebr sistemet Dorado V6 t\u00eb klas\u00ebs hi-end);<\/li>\n<li>mund\u00ebsia e ruajtjes federale (bashkimi i versioneve t\u00eb ndryshme t\u00eb Dorado si pjes\u00eb e nj\u00eb klasteri hibrid SCSI);<\/li>\n<li>virtualizimin inteligjent (mund\u00ebsia e p\u00ebrdorimit t\u00eb pajisjeve t\u00eb pal\u00ebve t\u00eb treta si pjes\u00eb e zgjidhjes Dorado).<\/li>\n<\/ul>\n<p>\n<img decoding=\"async\" alt=\"Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm i ruajtjes\" src=\"\/wp-content\/uploads\/2020\/04\/1071240678d16f4b941826eecabd67be.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nDuhet theksuar se situata e komplikuar n\u00eb bot\u00eb ka pasur nj\u00eb ndikim t\u00eb vog\u00ebl n\u00eb perspektivat tregtare t\u00eb sistemit t\u00eb ri. Megjith\u00ebse lan\u00e7imi zyrtar i Dorado V6 ishte vet\u00ebm n\u00eb janar, ne po shohim nj\u00eb k\u00ebrkes\u00eb t\u00eb konsiderueshme p\u00ebr t\u00eb n\u00eb Kin\u00eb, si dhe nj\u00eb interes t\u00eb madh nga partner\u00ebt rus\u00eb dhe nd\u00ebrkomb\u00ebtar\u00eb n\u00eb fush\u00ebn financiare dhe strukturat qeveritare.<\/p>\n<p>P\u00ebrve\u00e7 t\u00eb tjerash, lidhur me pandemin\u00eb, pavar\u00ebsisht se sa do t\u00eb zgjas\u00eb ajo, shfaqet nj\u00eb pyetje ve\u00e7an\u00ebrisht e mpreht\u00eb mbi sigurimin e punonj\u00ebsve t\u00eb distancuar me tavolina virtuale. N\u00eb k\u00ebt\u00eb proces, Dorado V6 do t\u00eb mund t\u00eb ofronte zgjidhje p\u00ebr shum\u00eb probleme. P\u00ebr k\u00ebt\u00eb, ne po b\u00ebjm\u00eb t\u00eb gjitha p\u00ebrpjekjet e nevojshme, p\u00ebrfshir\u00eb pothuajse arritjen e nj\u00eb marr\u00ebveshjeje p\u00ebr p\u00ebrfshirjen e sistemit t\u00eb ri n\u00eb list\u00ebn e pajtueshm\u00ebris\u00eb t\u00eb VMware.<\/p>\n<h2>***<\/h2>\n<p>\nP\u00ebr m\u00eb tep\u00ebr, mos harroni p\u00ebr webinar\u00ebt tan\u00eb t\u00eb shumt\u00eb, t\u00eb cil\u00ebt zhvillohen jo vet\u00ebm n\u00eb segmentin rusishtfol\u00ebs, por edhe n\u00eb nivel global. Lista e webinar\u00ebve p\u00ebr prillin \u00ebsht\u00eb e disponueshme n\u00eb <noindex><a rel=\"nofollow\" href=\"https:\/\/e.huawei.com\/ru\/special_topic\/event\/2020q1\/ru-webinar-schedule-2020\">linkun<\/a><\/noindex>.<br \/>\n<br \/>Burimi: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/huawei\/blog\/499502\/\">habr.com<\/a> <\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u041f\u043e\u0436\u0430\u043b\u0443\u0439\u0441\u0442\u0430, \u043d\u0435 \u0441\u043f\u0435\u0448\u0438\u0442\u0435 \u0441 \u0432\u044b\u0432\u043e\u0434\u0430\u043c\u0438 \u0438\u0437-\u0437\u0430 \u0437\u0430\u0433\u043e\u043b\u043e\u0432\u043a\u0430! \u0423 \u043d\u0430\u0441 \u0435\u0441\u0442\u044c \u0443\u0432\u0435\u0441\u0438\u0441\u0442\u044b\u0435 \u0430\u0440\u0433\u0443\u043c\u0435\u043d\u0442\u044b \u0432 \u0435\u0433\u043e \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435, \u0438 \u043c\u044b \u0443\u043f\u0430\u043a\u043e\u0432\u0430\u043b\u0438 \u0438\u0445, \u043d\u0430\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043c\u043e\u0433\u043b\u0438 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u043e. \u041f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u043c \u0432\u0430\u0448\u0435\u043c\u0443 \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u044e \u043f\u043e\u0441\u0442 \u043e \u043a\u043e\u043d\u0446\u0435\u043f\u0446\u0438\u0438 \u0438 \u043f\u0440\u0438\u043d\u0446\u0438\u043f\u0430\u0445 \u0440\u0430\u0431\u043e\u0442\u044b \u043d\u0430\u0448\u0435\u0439 \u043d\u043e\u0432\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u0434\u0430\u043d\u043d\u044b\u0445, \u0440\u0435\u043b\u0438\u0437 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0441\u043e\u0441\u0442\u043e\u044f\u043b\u0441\u044f \u0432 \u044f\u043d\u0432\u0430\u0440\u0435 2020 \u0433\u043e\u0434\u0430. \u041f\u043e \u043d\u0430\u0448\u0435\u043c\u0443 \u0443\u0431\u0435\u0436\u0434\u0435\u043d\u0438\u044e, \u0433\u043b\u0430\u0432\u043d\u043e\u0435 \u043a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442\u043d\u043e\u0435 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e \u0441\u0435\u043c\u0435\u0439\u0441\u0442\u0432\u0443 \u0421\u0425\u0414 Dorado V6 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0438\u043c\u0435\u043d\u043d\u043e [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":79692,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-79691","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u041f\u043e\u0436\u0430\u043b\u0443\u0439\u0441\u0442\u0430, \u043d\u0435 \u0441\u043f\u0435\u0448\u0438\u0442\u0435 \u0441 \u0432\u044b\u0432\u043e\u0434\u0430\u043c\u0438 \u0438\u0437-\u0437\u0430 \u0437\u0430\u0433\u043e\u043b\u043e\u0432\u043a\u0430! \u0423 \u043d\u0430\u0441 \u0435\u0441\u0442\u044c \u0443\u0432\u0435\u0441\u0438\u0441\u0442\u044b\u0435 \u0430\u0440\u0433\u0443\u043c\u0435\u043d\u0442\u044b \u0432 \u0435\u0433\u043e \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435, \u0438 \u043c\u044b \u0443\u043f\u0430\u043a\u043e\u0432\u0430\u043b\u0438 \u0438\u0445, \u043d\u0430\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043c\u043e\u0433\u043b\u0438 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u043e.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/pochemu-oceanstor-dorado-v6-samaya-bystraya-i-nadyozhnaya-shd\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2\" \/>\n\t\t<meta property=\"og:locale\" content=\"sq_AL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u041f\u043e\u0447\u0435\u043c\u0443 OceanStor Dorado V6 \u0441\u0430\u043c\u0430\u044f \u0431\u044b\u0441\u0442\u0440\u0430\u044f \u0438 \u043d\u0430\u0434\u0451\u0436\u043d\u0430\u044f \u0421\u0425\u0414 | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u041f\u043e\u0436\u0430\u043b\u0443\u0439\u0441\u0442\u0430, \u043d\u0435 \u0441\u043f\u0435\u0448\u0438\u0442\u0435 \u0441 \u0432\u044b\u0432\u043e\u0434\u0430\u043c\u0438 \u0438\u0437-\u0437\u0430 \u0437\u0430\u0433\u043e\u043b\u043e\u0432\u043a\u0430! \u0423 \u043d\u0430\u0441 \u0435\u0441\u0442\u044c \u0443\u0432\u0435\u0441\u0438\u0441\u0442\u044b\u0435 \u0430\u0440\u0433\u0443\u043c\u0435\u043d\u0442\u044b \u0432 \u0435\u0433\u043e \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435, \u0438 \u043c\u044b \u0443\u043f\u0430\u043a\u043e\u0432\u0430\u043b\u0438 \u0438\u0445, \u043d\u0430\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043c\u043e\u0433\u043b\u0438 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u043e.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/pochemu-oceanstor-dorado-v6-samaya-bystraya-i-nadyozhnaya-shd\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-04-29T17:42:18+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-04-29T17:42:18+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Pse OceanStor Dorado V6 \u00ebsht\u00eb sistemi i ruajtjes m\u00eb i shpejt\u00eb dhe m\u00eb i besuesh\u00ebm | ProHoster","description":"Ju lutemi, mos nxiteni n\u00eb p\u00ebrfundimet p\u00ebr shkak t\u00eb titullit! Ne kemi argumente t\u00eb forta p\u00ebr ta mb\u00ebshtetur at\u00eb, dhe i kemi paketuara aq kompakt sa kemi mundur.","canonical_url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/pochemu-oceanstor-dorado-v6-samaya-bystraya-i-nadyozhnaya-shd","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sq_AL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u041f\u043e\u0447\u0435\u043c\u0443 OceanStor Dorado V6 \u0441\u0430\u043c\u0430\u044f \u0431\u044b\u0441\u0442\u0440\u0430\u044f \u0438 \u043d\u0430\u0434\u0451\u0436\u043d\u0430\u044f \u0421\u0425\u0414 | ProHoster","og:description":"\u041f\u043e\u0436\u0430\u043b\u0443\u0439\u0441\u0442\u0430, \u043d\u0435 \u0441\u043f\u0435\u0448\u0438\u0442\u0435 \u0441 \u0432\u044b\u0432\u043e\u0434\u0430\u043c\u0438 \u0438\u0437-\u0437\u0430 \u0437\u0430\u0433\u043e\u043b\u043e\u0432\u043a\u0430! \u0423 \u043d\u0430\u0441 \u0435\u0441\u0442\u044c \u0443\u0432\u0435\u0441\u0438\u0441\u0442\u044b\u0435 \u0430\u0440\u0433\u0443\u043c\u0435\u043d\u0442\u044b \u0432 \u0435\u0433\u043e \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435, \u0438 \u043c\u044b \u0443\u043f\u0430\u043a\u043e\u0432\u0430\u043b\u0438 \u0438\u0445, \u043d\u0430\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043c\u043e\u0433\u043b\u0438 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u043e.","og:url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/pochemu-oceanstor-dorado-v6-samaya-bystraya-i-nadyozhnaya-shd","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-04-29T17:42:18+00:00","article:modified_time":"2020-04-29T17:42:18+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"79691","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 16:33:27","updated":"2022-10-02 20:00:56","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/79691","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/comments?post=79691"}],"version-history":[{"count":0,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/79691\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media\/79692"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media?parent=79691"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/categories?post=79691"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/tags?post=79691"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}