{"id":93332,"date":"2020-09-05T19:42:54","date_gmt":"2020-09-05T17:42:54","guid":{"rendered":"https:\/\/prohoster.info\/blog\/administrirovanie\/kak-my-postroili-sistemu-rezervnogo-energosnabzheniya-v-czod-tushino-inzheneriya-i-finansy"},"modified":"2020-09-05T19:42:54","modified_gmt":"2020-09-05T17:42:54","slug":"kak-my-postroili-sistemu-rezervnogo-energosnabzheniya-v-czod-tushino-inzheneriya-i-finansy","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/kak-my-postroili-sistemu-rezervnogo-energosnabzheniya-v-czod-tushino-inzheneriya-i-finansy","title":{"rendered":"Si e nd\u00ebrtuam sistemin e furnizimit me energji rezerv\u00eb n\u00eb Qendr\u00ebn e Dh\u00ebnash \"Tushino\": inxhinieria dhe financat","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><img decoding=\"async\" alt=\"Si e nd\u00ebrtuam sistemin e furnizimit me energji rezerv\u00eb n\u00eb Qendr\u00ebn e Dh\u00ebnash &quot;Tushino&quot;: inxhinieria dhe financat\" src=\"\/wp-content\/uploads\/2020\/09\/6d0ab1393d18a7f1109796156770fbce.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nQendra e t\u00eb Dh\u00ebnave \u201cTushino\u201d \u00ebsht\u00eb nj\u00eb qend\u00ebr t\u00eb dh\u00ebnash komerciale me gjysm\u00eb megavat p\u00ebr t\u00eb gjith\u00eb dhe p\u00ebr \u00e7do gj\u00eb. Klienti mund t\u00eb mos vet\u00ebm t\u00eb marr\u00eb me qira pajisjet e instaluara tashm\u00eb, por gjithashtu t\u00eb vendos\u00eb pajisjet e tij, duke p\u00ebrfshir\u00eb pajisje jo standarde si server\u00ebt n\u00eb kasetat e zakonshme p\u00ebr kompjuter\u00eb desktop, fermat e minierave ose sistemet e inteligjenc\u00ebs artificiale. Th\u00ebn\u00eb ndryshe, k\u00ebtu trajtohen nj\u00eb varg detyrash t\u00eb ndryshme, q\u00eb jan\u00eb m\u00eb t\u00eb k\u00ebrkuarat p\u00ebr biznesin vendas n\u00eb nivele t\u00eb ndryshme. Kjo \u00ebsht\u00eb arsyeja pse ai ka interes. N\u00eb k\u00ebt\u00eb postim nuk do t\u00eb gjeni zgjidhje teknike ekskluzive dhe fluturim t\u00eb mendjes inxhinierike. B\u00ebhet fjal\u00eb p\u00ebr problemet dhe zgjidhjet standarde. Pra, p\u00ebr at\u00eb q\u00eb 90% e specialist\u00ebve shpenzojn\u00eb 90% t\u00eb koh\u00ebs s\u00eb pun\u00ebs.<br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><\/p>\n<h3>Tier \u2014 sa m\u00eb shum\u00eb, aq m\u00eb mir\u00eb?<\/h3>\n<p>\nQ\u00ebndrueshm\u00ebria e Qendr\u00ebs s\u00eb t\u00eb Dh\u00ebnave \u201cTushino\u201d p\u00ebrputhet me nivelin Tier II. N\u00eb esenc\u00eb, kjo do t\u00eb thot\u00eb se qendra e t\u00eb dh\u00ebnave \u00ebsht\u00eb vendosur n\u00eb nj\u00eb ambient normal t\u00eb p\u00ebrgatitur, p\u00ebrdoren burime rezerv\u00eb energjie dhe ka burime sistemike t\u00eb tep\u00ebrta. <\/p>\n<p>Megjithat\u00eb, p\u00ebrkund\u00ebr nj\u00eb keqkuptimi t\u00eb zakonsh\u00ebm, nivelet Tier nuk karakterizojn\u00eb aspak \u201cm\u00eb t\u00eb mir\u00ebn\u201d e Qendr\u00ebs s\u00eb t\u00eb Dh\u00ebnave, por shkall\u00ebn e p\u00ebrputhjes s\u00eb saj me detyrat aktuale t\u00eb biznesit. Dhe midis tyre ka shum\u00eb q\u00eb, p\u00ebr shkak t\u00eb nivelit t\u00eb lart\u00eb t\u00eb q\u00ebndrueshm\u00ebris\u00eb, nuk \u00ebsht\u00eb thelb\u00ebsore ose nuk \u00ebsht\u00eb aq e r\u00ebnd\u00ebsishme sa p\u00ebr t\u00eb paguar shtes\u00eb 20-25 mij\u00eb rubla n\u00eb vit, q\u00eb n\u00eb kushte krize mund t\u00eb jet\u00eb shum\u00eb e dhimbshme p\u00ebr klientin.<\/p>\n<p>Nga erdhi ky shum\u00ebs? Ai p\u00ebrfaq\u00ebson sakt\u00ebsisht diferenc\u00ebn midis \u00e7mimeve p\u00ebr ruajtjen e informacionit n\u00eb <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/sq\/kompaniya\/data-centers\/\"   title=\"\u0434\u0430\u0442\u0430-\u0446\u0435\u043d\u0442\u0440\u0430\u0445\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"4670\">\u0434\u0430\u0442\u0430-\u0446\u0435\u043d\u0442\u0440\u0430\u0445<\/a> t\u00eb nivelit Tier II dhe Tier III p\u00ebr nj\u00eb server. Sa m\u00eb shum\u00eb t\u00eb dh\u00ebna, aq m\u00eb e dukshme \u00ebsht\u00eb potenciali i kursimit.<\/p>\n<p>Cilat jan\u00eb detyrat n\u00eb fjal\u00eb? P.sh., ruajtja e kopjeve rezerv\u00eb ose miniera e cryptocurrency. N\u00eb k\u00ebto raste, nj\u00eb <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/sq\/server\/dts-los-angeles\/\"   title=\"\u0441\u0435\u0440\u0432\u0435\u0440\u0430\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"3654\">\u0441\u0435\u0440\u0432\u0435\u0440\u0430<\/a>, e lejuar nga Tier II, do t\u00eb kushtoj\u00eb m\u00eb lir\u00eb se Tier III.<\/p>\n<p>Praktika tregon se n\u00eb shumic\u00ebn e rasteve, kursimi \u00ebsht\u00eb m\u00eb i r\u00ebnd\u00ebsish\u00ebm se q\u00ebndrueshm\u00ebria e shtuar. N\u00eb Mosk\u00eb, funksionojn\u00eb vet\u00ebm pes\u00eb Qendra t\u00eb t\u00eb Dh\u00ebnave t\u00eb certifikuara sipas Tier III. Dhe nuk ka asnj\u00eb q\u00eb \u00ebsht\u00eb plot\u00ebsisht e certifikuar sipas Tier IV. <\/p>\n<h3>Si \u00ebsht\u00eb e organizuar sistemi i furnizimit me energji t\u00eb Qendr\u00ebs s\u00eb t\u00eb Dh\u00ebnave \u201cTushino\u201d?<\/h3>\n<p>\nK\u00ebrkesat p\u00ebr sistemin e furnizimit me energji t\u00eb Qendr\u00ebs s\u00eb t\u00eb Dh\u00ebnave \"Tushino\" i p\u00ebrmbushin kushtet e nivelit Tier II. Kjo p\u00ebrfshin rezervimin e linjave t\u00eb energjis\u00eb sipas skem\u00ebs N+1, rezervimin e burimeve t\u00eb energjis\u00eb pa nd\u00ebrprerje sipas skem\u00ebs N+1 dhe rezervimin e gjenerator\u00ebve diesel sipas skem\u00ebs N. N+1 n\u00ebnkupton nj\u00eb skem\u00eb me nj\u00eb element rezerv\u00eb, i cili mbetet jo i angazhuar derisa n\u00eb sistem t\u00eb ndodh\u00eb nj\u00eb defekt n\u00eb nj\u00eb nga element\u00ebt kryesor\u00eb, nd\u00ebrsa N n\u00ebnkupton nj\u00eb skem\u00eb pa rezervim, ku nj\u00eb defekt n\u00eb funksionimin e \u00e7do elementi \u00e7on n\u00eb pezullimin e t\u00eb gjith\u00eb sistemit.<\/p>\n<p>Shum\u00eb probleme t\u00eb lidhura me furnizimin me energji zgjidhen p\u00ebrmes zgjedhjes s\u00eb duhur t\u00eb vendit p\u00ebr Qendr\u00ebn e t\u00eb Dh\u00ebnave. Qendra e t\u00eb Dh\u00ebnave \"Tushino\" \u00ebsht\u00eb e vendosur n\u00eb territorin e nj\u00eb fabrik\u00eb, ku tashm\u00eb arrijn\u00eb dy linja 110 kV nga centrale t\u00eb ndryshme t\u00eb qytetit. N\u00eb pajisjet e fabrik\u00ebs, tensioni i lart\u00eb shnd\u00ebrrohet n\u00eb t\u00eb mes\u00ebm, dhe n\u00eb hyrjen e Qendr\u00ebs s\u00eb t\u00eb Dh\u00ebnave vijn\u00eb dy linja t\u00eb pavarura 10 kV. <\/p>\n<p>Stacioni transformues brenda nd\u00ebrtes\u00ebs s\u00eb Qendr\u00ebs s\u00eb t\u00eb Dh\u00ebnave shnd\u00ebrron tensionin e mes\u00ebm n\u00eb tensionin konsumer 240-400 V. T\u00eb gjitha linjat shkojn\u00eb paralelisht, k\u00ebshtu q\u00eb pajisjet e Qendr\u00ebs s\u00eb t\u00eb Dh\u00ebnave marrin energji nga dy burime t\u00eb jashtme t\u00eb pavarura.<\/p>\n<p>Tensioni i ul\u00ebt nga stacionet transformuese \u00ebsht\u00eb i lidhur me automatik\u00ebt e hyrjes p\u00ebr rezerv\u00eb, t\u00eb cil\u00ebt sigurojn\u00eb kalimin midis rrjeteve t\u00eb qytetit. P\u00ebr t\u00eb k\u00ebt\u00eb operacion, motor\u00ebt e vendosur n\u00eb AVR k\u00ebrkojn\u00eb 1.2 sekonda. Gjat\u00eb gjith\u00eb k\u00ebtij koh\u00eb, ngarkesa bie mbi burimet e energjis\u00eb pa nd\u00ebrprerje.<\/p>\n<p>Nj\u00eb AVR i ve\u00e7ant\u00eb \u00ebsht\u00eb p\u00ebrgjegj\u00ebs p\u00ebr aktivizimin automatik t\u00eb gjeneratorit diesel n\u00eb rast se energjia p\u00ebrfundohet n\u00eb t\u00eb dy linjat. Nisja e gjeneratorit diesel \u00ebsht\u00eb nj\u00eb proces jo i shpejt\u00eb dhe k\u00ebrkon rreth 40 sekonda, gjat\u00eb t\u00eb cilave furnizimi me energji d\u00ebshtuar plot\u00ebsisht bie mbi baterit\u00eb e UPS. <\/p>\n<p>Me nj\u00eb mbushje t\u00eb plot\u00eb, gjeneratori me naft\u00eb siguron funksionimin e qendr\u00ebs s\u00eb t\u00eb dh\u00ebnave p\u00ebr 8 or\u00eb. Duke marr\u00eb parasysh k\u00ebt\u00eb, qendra e t\u00eb dh\u00ebnave ka lidhur dy kontrata me furnizues t\u00eb pavarur t\u00eb naft\u00ebs, t\u00eb cil\u00ebt kan\u00eb premtuar t\u00eb sjellin nj\u00eb sasi t\u00eb re karburanti brenda 4 or\u00ebve pas thirrjes. Probabiliteti q\u00eb t\u00eb dy t\u00eb ken\u00eb ndonj\u00eb rrethan\u00eb t\u00eb papritur n\u00eb t\u00eb nj\u00ebjt\u00ebn koh\u00eb \u00ebsht\u00eb jasht\u00ebzakonisht i ul\u00ebt. Prandaj, autonomi mund t\u00eb vazhdoj\u00eb sa her\u00eb q\u00eb ekipet e riparimit kan\u00eb nevoj\u00eb p\u00ebr t\u00eb rinovuar energjin\u00eb, s\u00eb paku nga nj\u00ebra nga rrjetet urbane.<\/p>\n<p>Si\u00e7 \u00ebsht\u00eb leht\u00eb e dukshme, nuk ka asnj\u00eb inxhinieri t\u00eb ve\u00e7ant\u00eb k\u00ebtu. Kjo \u00ebsht\u00eb pjes\u00ebrisht p\u00ebr shkak se n\u00eb nd\u00ebrtimin e infrastruktur\u00ebs inxhinierike jan\u00eb p\u00ebrdorur module t\u00eb gatshme, prodhuesit e t\u00eb cil\u00ebve orientohen n\u00eb nj\u00eb \u2018p\u00ebrdorues t\u00eb mes\u00ebm\u2019.<\/p>\n<p>Sigurisht, \u00e7do specialist i IT-s\u00eb do t\u00eb thot\u00eb se mesataria \u00ebsht\u00eb \u2018asnj\u00eb peshk, as mish\u2019 dhe do t\u00eb propozoj\u00eb zhvillimin e nj\u00eb grupe unik komponentesh p\u00ebr nj\u00eb sistem t\u00eb ve\u00e7ant\u00eb. Megjithat\u00eb, ata q\u00eb duan t\u00eb paguajn\u00eb p\u00ebr k\u00ebt\u00eb k\u00ebnaq\u00ebsi nuk po rreshtohen p\u00ebr k\u00ebt\u00eb. Prandaj, duhet t\u00eb jemi realist\u00eb. N\u00eb praktik\u00eb, gjith\u00e7ka do t\u00eb jet\u00eb k\u00ebshtu: blerja e pajisjeve t\u00eb gatshme dhe montimi i nj\u00eb sistemi q\u00eb do t\u00eb zgjidh\u00eb probleme aktuale p\u00ebr biznesin. Ata q\u00eb nuk pajtohen me k\u00ebt\u00eb qasje do t\u00eb kthehen shpejt n\u00eb realitet nga CFO i kompanis\u00eb.<\/p>\n<h3>Panel\u00ebt shp\u00ebrndar\u00ebs<\/h3>\n<p>\nAktualisht, n\u00ebnt\u00eb panel\u00ebt shp\u00ebrndar\u00ebs sigurojn\u00eb funksionimin e pajisjeve hyr\u00ebse-shp\u00ebrndar\u00ebse dhe kat\u00ebr RSh p\u00ebrdoren p\u00ebr lidhjen direkte t\u00eb ngarkes\u00ebs. Nuk ka pasur ndonj\u00eb kufizim t\u00eb serioz p\u00ebr vendin, megjithat\u00eb ai kurr\u00eb nuk \u00ebsht\u00eb shum\u00eb, prandaj ka pasur nj\u00eb moment t\u00eb interesant inxhinierik.<\/p>\n<p>Si\u00e7 \u00ebsht\u00eb leht\u00eb e dukshme, numri i panel\u00ebve 'hyr\u00ebs' dhe 'ngarkues' nuk p\u00ebrputhet - t\u00eb dyt\u00ebt jan\u00eb pothuajse dy her\u00eb m\u00eb t\u00eb pak\u00ebt. Kjo \u00ebsht\u00eb b\u00ebr\u00eb e mundur sepse projektuesit e infrastruktur\u00ebs s\u00eb qendr\u00ebs s\u00eb t\u00eb dh\u00ebnave vendos\u00ebn t\u00eb p\u00ebrdorin panel\u00eb m\u00eb t\u00eb m\u00ebdhenj p\u00ebr t\u00eb lejuar tri ose m\u00eb shum\u00eb linja hyr\u00ebse. P\u00ebr \u00e7do automatik hyr\u00ebs ka rreth 36 linja dal\u00ebse, t\u00eb mbrojtura nga automatik\u00eb t\u00eb ve\u00e7ant\u00eb. <\/p>\n<p>Prandaj, ndonj\u00ebher\u00eb p\u00ebrdorimi i modeleve m\u00eb t\u00eb m\u00ebdha ndihmon p\u00ebr t\u00eb kursyer hap\u00ebsir\u00ebn e kufizuar. Thjesht sepse do t\u00eb nevojiten m\u00eb pak panel\u00eb t\u00eb m\u00ebdhenj. <\/p>\n<h3>Burimet e energjis\u00eb s\u00eb pand\u00ebrprer\u00eb<\/h3>\n<p>\nSi burim i energjis\u00eb s\u00eb pand\u00ebrprer\u00eb n\u00eb Qendr\u00ebn e T\u00eb Dh\u00ebnave \"Tushino\" p\u00ebrdoret Eaton 93PM me kapacitet 120 kV\u00b7A, punon n\u00eb modalitetin e konvertimit t\u00eb dyfisht\u00eb. <\/p>\n<p><img decoding=\"async\" alt=\"Si e nd\u00ebrtuam sistemin e furnizimit me energji rezerv\u00eb n\u00eb Qendr\u00ebn e Dh\u00ebnash &quot;Tushino&quot;: inxhinieria dhe financat\" src=\"\/wp-content\/uploads\/2020\/09\/ead096b3ebc47fd8fa9cb58aa2d49f59.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<i>UPS Eaton 93PM prodhohen n\u00eb versione t\u00eb ndryshme. Foto: Eaton <\/i><\/p>\n<p>Arsyet kryesore p\u00ebrzgjedhjes s\u00eb k\u00ebtij aparati jan\u00eb karakteristikat e tij t\u00eb m\u00ebposhtme. <\/p>\n<p>S\u00eb pari, efikasiteti i k\u00ebtij UPS n\u00eb modalitetin e konvertimit t\u00eb dyfisht\u00eb arrin 97%, nd\u00ebrsa n\u00eb modalitetin e ruajtjes s\u00eb energjis\u00eb \u2014 99%. Pajisja z\u00eb m\u00eb pak se 1,5 m\u00b2 dhe nuk merr hap\u00ebsir\u00eb n\u00eb dhom\u00ebn e serverit p\u00ebr pajisjet kryesore. Si rezultat, kostoja e ul\u00ebt operative dhe kursimi i d\u00ebshiruar p\u00ebr biznesin arrihen. <\/p>\n<p>S\u00eb dyti, fal\u00eb sistemit t\u00eb integruar t\u00eb termoregulimit, UPS Eaton 93PM mund t\u00eb vendoset kudo. Edhe ngjitur me murin. Edhe n\u00ebse kjo nuk \u00ebsht\u00eb e nevojshme menj\u00ebher\u00eb, ajo mund t\u00eb k\u00ebrkohet m\u00eb von\u00eb. P\u00ebr shembull, p\u00ebr t\u00eb liruar pak hap\u00ebsir\u00eb t\u00eb nevojshme p\u00ebr nj\u00eb kabinet shtes\u00eb. <\/p>\n<p>S\u00eb treti, thjesht\u00ebsia e p\u00ebrdorimit. P\u00ebrfshir\u00eb softuerin Intelligent Power, i p\u00ebrdorur p\u00ebr monitorimin dhe menaxhimin. Metodat q\u00eb kthehen p\u00ebrmes SNMP lejojn\u00eb kontrollin e konsumit dhe ndonj\u00eb defekt global, \u00e7ka jep mund\u00ebsin\u00eb t\u00eb reagosh shpejt ndaj situatave emergjente. <\/p>\n<p>S\u00eb kat\u00ebrti, modulariteti dhe shkall\u00ebzueshm\u00ebria. Kjo, ndoshta, \u00ebsht\u00eb cil\u00ebsia m\u00eb e r\u00ebnd\u00ebsishme, p\u00ebr t\u00eb cil\u00ebn n\u00eb sistemin e rezervimit t\u00eb Qendr\u00ebs s\u00eb T\u00eb Dh\u00ebnave \"Tushino\" p\u00ebrdoret vet\u00ebm nj\u00eb UPS modular. Ai p\u00ebrmban dy module funksionale dhe nj\u00eb rezerv\u00eb. K\u00ebshtu sigurohet skema N+1, e nevojshme p\u00ebr nivelin Tier II.<\/p>\n<p>Kjo \u00ebsht\u00eb ndjesh\u00ebm m\u00eb e leht\u00eb dhe m\u00eb e besueshme se konfigurimi me tri UPS. Prandaj, zgjedhja e nj\u00eb pajisjeje, n\u00eb t\u00eb cil\u00ebn parashikohet fillimisht mund\u00ebsia e funksionimit paralel \u2014 \u00ebsht\u00eb nj\u00eb vendim mjaft i logjiksh\u00ebm. <\/p>\n<p>Por pse projektuesit nuk zgjodh\u00ebn DRUPS n\u00eb vend t\u00eb UPS-ve t\u00eb ve\u00e7anta dhe gjeneratorit t\u00eb dizel? Arsyet kryesore k\u00ebtu jan\u00eb gjithashtu t\u00eb vendosura jo n\u00eb inxhinieri, por n\u00eb financa.<\/p>\n<p>Struktura modulare \u00ebsht\u00eb parimisht e dizajnuar p\u00ebr p\u00ebrmir\u00ebsim - me rritjen e ngarkes\u00ebs, n\u00eb infrastruktur\u00ebn inxhinierike shtohen burime dhe gjenerator\u00eb. Old k\u00ebshtu q\u00eb si punonin, ashtu vazhdojn\u00eb t\u00eb punojn\u00eb. Situata me DRIBP \u00ebsht\u00eb krejt ndryshe: blerja e nj\u00eb pajisjeje t\u00eb till\u00eb duhet t\u00eb b\u00ebhet me nj\u00eb rezerv\u00eb t\u00eb madhe t\u00eb fuqis\u00eb. P\u00ebr m\u00eb tep\u00ebr, \"kombajn\u00ebt e vegj\u00ebl\" jan\u00eb t\u00eb pak\u00ebt dhe shtrenjtohen shum\u00eb - t\u00eb paparashikueshme m\u00eb shum\u00eb se gjenerator\u00ebt diesel dhe UPS t\u00eb ve\u00e7ant\u00eb. Gjithashtu, DRIBP jan\u00eb shum\u00eb t\u00eb ndjesh\u00ebm p\u00ebr transport dhe instalim. Kjo, nga ana tjet\u00ebr, ndikon n\u00eb koston e t\u00ebr\u00eb sistemit. <\/p>\n<p>Konfigurimi ekzistues zgjidh problemet e tij mjaft me sukses. UPS Eaton 93PM mund t\u00eb mb\u00ebshtes\u00eb pun\u00ebn e pajisjeve kryesore t\u00eb data qendr\u00ebs gjat\u00eb 15 minutave, q\u00eb do t\u00eb thot\u00eb, me nj\u00eb rezerv\u00eb m\u00eb shum\u00eb se 15-fish. <\/p>\n<p>Edhe nj\u00eb her\u00eb, sinusoida e past\u00ebr q\u00eb UPS e ofron n\u00eb modin online e \u00e7liron pronarin e data qendr\u00ebs nga nevoja p\u00ebr t\u00eb bler\u00eb stabilizator\u00eb t\u00eb ve\u00e7ant\u00eb. Dhe k\u00ebtu del ekonomia. <\/p>\n<p>Pavar\u00ebsisht thjesht\u00ebsis\u00eb s\u00eb deklaruar t\u00eb UPS Eaton 93PM - pajisja \u00ebsht\u00eb mjaft e komplikuar. Prandaj, mir\u00ebmbajtja e saj teknike n\u00eb data qendr\u00ebn \"Tushino\" b\u00ebhet nga nj\u00eb kompani e jashtme, e cila ka n\u00eb kuad\u00ebr specialist\u00eb t\u00eb kualifikuar mir\u00eb. T\u00eb mbash nj\u00eb punonj\u00ebs t\u00eb trajnuar n\u00eb kuad\u00ebr p\u00ebr k\u00ebt\u00eb q\u00ebllim \u00ebsht\u00eb nj\u00eb k\u00ebnaq\u00ebsi e shtrenjt\u00eb. <\/p>\n<h3>Rezultatet dhe Perspektivat<\/h3>\n<p>\nK\u00ebshtu u nd\u00ebrtua data qendra q\u00eb mund\u00ebson ofrimin e sh\u00ebrbimeve cil\u00ebsore p\u00ebr konsumator\u00ebt, detyrat e t\u00eb cil\u00ebve nuk k\u00ebrkojn\u00eb nj\u00eb nivel t\u00eb lart\u00eb rezervimi dhe nuk parashikojn\u00eb shpenzime t\u00eb m\u00ebdha ekonomike. Nj\u00eb sh\u00ebrbim i till\u00eb gjithmon\u00eb do t\u00eb jet\u00eb i k\u00ebrkuar.<\/p>\n<p>Me nd\u00ebrtimin tashm\u00eb t\u00eb planifikuar t\u00eb faz\u00ebs s\u00eb dyt\u00eb, p\u00ebr krijimin e sistemit t\u00eb furnizimit me energji rezerv\u00eb do t\u00eb p\u00ebrdoret UPS Eaton i bler\u00eb tashm\u00eb. Fal\u00eb struktur\u00ebs modulare, modernizimi i tij do t\u00eb reduktohet n\u00eb blerjen e nj\u00eb moduli shtes\u00eb, q\u00eb \u00ebsht\u00eb m\u00eb e leht\u00eb dhe m\u00eb e lir\u00eb se z\u00ebvend\u00ebsimi i plot\u00eb i pajisjes. Nj\u00eb qasje t\u00eb till\u00eb do ta miratojn\u00eb si inxhinieri ashtu edhe financieri.<br \/>\n<br \/>Burimi: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/eaton\/blog\/517660\/\">habr.com<\/a> <\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0426\u041e\u0414 \u00ab\u0422\u0443\u0448\u0438\u043d\u043e\u00bb \u2014 \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u043e\u0437\u043d\u0438\u0447\u043d\u044b\u0439 \u043f\u043e\u043b\u0443\u043c\u0435\u0433\u0430\u0432\u0430\u0442\u0442\u043d\u044b\u0439 \u0434\u0430\u0442\u0430-\u0446\u0435\u043d\u0442\u0440 \u0434\u043b\u044f \u0432\u0441\u0435\u0445 \u0438 \u0434\u043b\u044f \u0432\u0441\u0435\u0433\u043e. \u041a\u043b\u0438\u0435\u043d\u0442 \u043c\u043e\u0436\u0435\u0442 \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u0430\u0440\u0435\u043d\u0434\u043e\u0432\u0430\u0442\u044c \u0443\u0436\u0435 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u043d\u043e \u0438 \u0440\u0430\u0437\u043c\u0435\u0441\u0442\u0438\u0442\u044c \u0442\u0430\u043c \u0441\u043e\u0431\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0435, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u043d\u0435\u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0442\u0438\u043f\u0430 \u0441\u0435\u0440\u0432\u0435\u0440\u043e\u0432 \u0432 \u043e\u0431\u044b\u0447\u043d\u044b\u0445 \u043a\u043e\u0440\u043f\u0443\u0441\u0430\u0445 \u0434\u043b\u044f \u043d\u0430\u0441\u0442\u043e\u043b\u044c\u043d\u044b\u0445 \u041f\u041a, \u043c\u0430\u0439\u043d\u0438\u043d\u0433-\u0444\u0435\u0440\u043c \u0438\u043b\u0438 \u0441\u0438\u0441\u0442\u0435\u043c \u0438\u0441\u043a\u0443\u0441\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0433\u043e \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0430. \u041f\u0440\u043e\u0449\u0435 \u0433\u043e\u0432\u043e\u0440\u044f, \u044d\u0442\u043e \u0441\u0430\u043c\u044b\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0435 \u043f\u043e\u043f\u0443\u043b\u044f\u0440\u043d\u044b\u0435 \u0437\u0430\u0434\u0430\u0447\u0438, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0432\u043e\u0441\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043e\u0442\u0435\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u043c \u0431\u0438\u0437\u043d\u0435\u0441\u043e\u043c \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u043e\u0439 \u0441\u0442\u0435\u043f\u0435\u043d\u0438 \u0432\u0435\u043b\u0438\u0447\u0438\u043d\u044b. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":93333,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-93332","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0426\u041e\u0414.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/kak-my-postroili-sistemu-rezervnogo-energosnabzheniya-v-czod-tushino-inzheneriya-i-finansy\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"sq_AL\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u041a\u0430\u043a \u043c\u044b \u043f\u043e\u0441\u0442\u0440\u043e\u0438\u043b\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u0440\u0435\u0437\u0435\u0440\u0432\u043d\u043e\u0433\u043e \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u044f \u0432 \u0426\u041e\u0414 \u00ab\u0422\u0443\u0448\u0438\u043d\u043e\u00bb: \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u0438\u044f \u0438 \u0444\u0438\u043d\u0430\u043d\u0441\u044b | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0426\u041e\u0414.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/kak-my-postroili-sistemu-rezervnogo-energosnabzheniya-v-czod-tushino-inzheneriya-i-finansy\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-09-05T17:42:54+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2020-09-05T17:42:54+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Si nd\u00ebrtuam sistemin e furnizimit me energji rezerv\u00eb n\u00eb data qendr\u00ebn \"Tushino\": inxhinieria dhe financat | ProHoster","description":"Data Qendra.","canonical_url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/kak-my-postroili-sistemu-rezervnogo-energosnabzheniya-v-czod-tushino-inzheneriya-i-finansy","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sq_AL","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u041a\u0430\u043a \u043c\u044b \u043f\u043e\u0441\u0442\u0440\u043e\u0438\u043b\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u0440\u0435\u0437\u0435\u0440\u0432\u043d\u043e\u0433\u043e \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u044f \u0432 \u0426\u041e\u0414 \u00ab\u0422\u0443\u0448\u0438\u043d\u043e\u00bb: \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u0438\u044f \u0438 \u0444\u0438\u043d\u0430\u043d\u0441\u044b | ProHoster","og:description":"\u0426\u041e\u0414.","og:url":"https:\/\/prohoster.info\/sq\/blog\/administrirovanie\/kak-my-postroili-sistemu-rezervnogo-energosnabzheniya-v-czod-tushino-inzheneriya-i-finansy","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2020-09-05T17:42:54+00:00","article:modified_time":"2020-09-05T17:42:54+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"93332","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-02-28 11:49:44","updated":"2026-02-22 15:29:37","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/93332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/comments?post=93332"}],"version-history":[{"count":2,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/93332\/revisions"}],"predecessor-version":[{"id":164548,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/posts\/93332\/revisions\/164548"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media\/93333"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/media?parent=93332"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/categories?post=93332"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sq\/wp-json\/wp\/v2\/tags?post=93332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}