{"id":38294,"date":"2019-10-31T22:22:48","date_gmt":"2019-10-31T19:22:48","guid":{"rendered":"https:\/\/prohoster.info\/blog\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\/"},"modified":"2019-10-31T22:22:48","modified_gmt":"2019-10-31T19:22:48","slug":"anboksing-stoechnogo-servera-cisco-ucs-c240-m5","status":"publish","type":"post","link":"https:\/\/prohoster.info\/sv\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","title":{"rendered":"Unboxing av rackservern Cisco UCS C240 M5","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p>Idag har vi en ny rackserver, Cisco UCS C240 av femte generationen, p\u00e5 bordet. <\/p>\n<p>Vad g\u00f6r just denna server fr\u00e5n Cisco intressant f\u00f6r unboxing, med tanke p\u00e5 att vi har att g\u00f6ra med dess femte generation? <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing av rackservern Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/419d39ba895739a71b337f03445a9c32.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nF\u00f6r det f\u00f6rsta st\u00f6der Cisco-servrar nu den senaste generationen av Intel Scalable-processorer av andra generationen. F\u00f6r det andra kan man nu installera Optane Memory-moduler f\u00f6r att anv\u00e4nda flera NVMe-enheter. <br \/>\n<noindex><a rel=\"nofollow\" name=\"habracut\"><\/a><\/noindex><br \/>\nDet v\u00e4cks rimliga fr\u00e5gor: kan inte servrar fr\u00e5n andra tillverkare g\u00f6ra detta? Vad \u00e4r egentligen s\u00e5 speciellt, eftersom det bara \u00e4r en x86-server? Vi g\u00e5r igenom allt steg f\u00f6r steg. <\/p>\n<p>F\u00f6rutom att fungera som en frist\u00e5ende server kan Cisco C240 M5 bli en del av Cisco UCS-arkitekturen. H\u00e4r pratar vi om anslutning till FI och fullst\u00e4ndig hantering av servrar med UCS Manager, inklusive Auto Deploy. <\/p>\n<p>S\u00e5 h\u00e4r har vi en \"j\u00e4rn\"-server fr\u00e5n Cisco, dess femte generation, med \u00f6ver 10 \u00e5r p\u00e5 marknaden. <br \/>\nNu g\u00e5r vi tillbaka till grunderna och p\u00e5minner oss om vilka komponenter en server best\u00e5r av, och vad som g\u00f6r Cisco C240 M5 inte bara modern, utan verkligen banbrytande. <\/p>\n<p>L\u00e5t oss titta p\u00e5 vad som ing\u00e5r i leveransen. <\/p>\n<p><b>Inneh\u00e5ll i l\u00e5dan<\/b>: servern, KVM-dongel, dokumentation, skiva, 2 str\u00f6mkablar, installationskit. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing av rackservern Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/4e6b39ebc4a78f8b37b29ea2d76da14e.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nVi tar av locket. Trycker, skiftar och klart. Inga skruvmejslar eller f\u00f6rsvunna skruvar. <br \/>\nDet f\u00f6rsta som f\u00e5ngar \u00f6gat \u00e4r de gr\u00f6na etiketterna. Alla element som st\u00f6der hot-swap har dem. Till exempel kan fl\u00e4ktarna enkelt bytas utan att st\u00e4nga av str\u00f6mmen till hela servern. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing av rackservern Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/cb2fcaf627f96dd947421f65e80c2638.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nVi ser ocks\u00e5 massiv kylning under vilka de nya Intel Scal 2 Gen-processorerna d\u00f6ljer sig. Observera att detta ger upp till 56 k\u00e4rnor p\u00e5 en 2U-server utan n\u00e5gra problem med kylning. Dessutom st\u00f6ds mer minne, upp till 1TB per processor. Den st\u00f6dda minnesfrekvensen har ocks\u00e5 \u00f6kat till 2933 MHz. <\/p>\n<p>Bredvid CPU:n ser vi 24 platser f\u00f6r RAM-minne \u2014 man kan anv\u00e4nda moduler upp till 128 GB eller Intel Optane-minne upp till 512 GB per slot.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing av rackservern Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/147f87e31e346dbb0f360c92dccde512.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIntel Optane \u00f6ppnar upp f\u00f6r otroliga hastigheter. Till exempel kan det anv\u00e4ndas som en super snabb lokal SSD.<\/p>\n<p>Nu b\u00f6rjar allt fler f\u00f6rfr\u00e5gningar fr\u00e5n kunder med orden: \"Jag vill ha fler enheter, fler NVMe-enheter i ett system.\" <\/p>\n<p>P\u00e5 framsidan ser vi 8 platser f\u00f6r 2,5-tums lagringsenheter. Det finns ocks\u00e5 en variant av plattformen med standard 24 platser tillg\u00e4nglig f\u00f6r best\u00e4llning framifr\u00e5n.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing av rackservern Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/ddeca4947e941f1dadfe2a691b8729d8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nBeroende p\u00e5 modifiering kan upp till 8 NMVe-diskar i U.2-formfaktor installeras i de f\u00f6rsta slotarna. <\/p>\n<p>Plattformen C240 \u00e4r generellt mycket popul\u00e4r bland kunder som arbetar med stora m\u00e4ngder data. Deras huvudbeg\u00e4ran \u00e4r m\u00f6jligheten att ha lagringsenheter f\u00f6r lokal inladdning och helst hot pluggable.<\/p>\n<p>Svaret p\u00e5 denna beg\u00e4ran blev Cisco-l\u00f6sningen i C240 M5 som l\u00e4gger till tv\u00e5 platser f\u00f6r diskar med st\u00f6d f\u00f6r varm byte bak p\u00e5 servern.<\/p>\n<p>De \u00e4r placerade till h\u00f6ger om expansionsslotarna och str\u00f6mf\u00f6rs\u00f6rjningsmodulerna. Lagringsenheterna kan vara av alla slag: SAS, SATA, SSD, NVMe.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing av rackservern Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/33ef5ba06667b6e130ce724bd27cf857.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nIntill ser vi 1600W str\u00f6mf\u00f6rs\u00f6rjningsmoduler. De \u00e4r ocks\u00e5 Hot Pluggable och har gr\u00f6na etiketter.<\/p>\n<p><img decoding=\"async\" alt=\"Unboxing av rackservern Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/46ab4548bc3d84d497f772f7c8eaa633.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nF\u00f6r att arbeta med disksystemet kan en RAID-kontroller fr\u00e5n LSI med 2 GB cache installeras i en dedikerad slot eller ett HBA-kort f\u00f6r direkt bypass.<\/p>\n<p>Till exempel anv\u00e4nds ett s\u00e5dant angreppss\u00e4tt vid uppbyggnaden av den hyperkonvergerade l\u00f6sningen Cisco HyperFlex.<\/p>\n<p>Det finns en annan typ av kunder som inte alls beh\u00f6ver diskar. De vill inte installera en hel RAID-kontroller f\u00f6r hypervisorn, men de gillar 2U-chassit f\u00f6r sin bekv\u00e4mlighet vid underh\u00e5ll.<br \/>\nF\u00f6r dem har Cisco ocks\u00e5 en l\u00f6sning.<\/p>\n<p>Jag presenterar FlexFlash-modulen:<br \/>\nTv\u00e5 SD-kort med kapacitet upp till 128 GB, med st\u00f6d f\u00f6r spegling, f\u00f6r installation av hypervisorn, till exempel VMware ESXi. Det \u00e4r just denna variant vi p\u00e5 ITGLOBAL.COM anv\u00e4nder f\u00f6r att bygga v\u00e5ra egna plattformar \u00f6ver hela v\u00e4rlden. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing av rackservern Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/d265c93e1e60428c69132b3cddb3a790.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nF\u00f6r de kunder som beh\u00f6ver mer utrymme f\u00f6r att ladda operativsystem, finns det en modulversion med tv\u00e5 'SATA'-SSD-diskar i M.2-format, med kapacitet p\u00e5 240 eller 960 GB vardera. Som standard \u00e4r det programvaru-RAID. <\/p>\n<p>F\u00f6r 240 GB lagringsenheter finns det en m\u00f6jlighet att anv\u00e4nda Cisco Boot optimized M.2 RAID-kontroller \u2014 en separat h\u00e5rdvaru-RAID-kontroller f\u00f6r dessa tv\u00e5 SSD-lagringsenheter.<\/p>\n<p>Allt detta st\u00f6ds av alla operativsystem: b\u00e5de VMware och Windows samt olika Linux OS.<br \/>\nAntalet PCI-slotar \u00e4r 6, vilket \u00e4r typiskt f\u00f6r en 2U-plattform. <\/p>\n<p><img decoding=\"async\" alt=\"Unboxing av rackservern Cisco UCS C240 M5\" src=\"\/wp-content\/uploads\/2019\/09\/67f57214e9f99cbad0add05865ed83f8.png\" style=\"display:block;margin: 0 auto;\" \/><br \/>\n<br \/>\nDet finns gott om utrymme inuti. I servrarna \u00e4r det enkelt att installera tv\u00e5 fullstora grafiska acceleratorer fr\u00e5n NVidia, exempelvis TESLA M10 f\u00f6r implementationsprojekt <a class=\"wpil_keyword_link\" href=\"https:\/\/prohoster.info\/sv\/vps\/abuzoustojchivye-vps\/\"   title=\"virtuella skrivbord\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"1009\">virtuella skrivbord<\/a> eller den senaste V100-versionen p\u00e5 32GB f\u00f6r artificiell intelligensuppgifter. Den kommer vi att anv\u00e4nda i n\u00e4sta unboxing.<\/p>\n<p>Ang\u00e5ende portar ser det ut s\u00e5 h\u00e4r: <\/p>\n<ul>\n<li>Konsolport;<\/li>\n<li>Gigabit dedikerad hanteringsport;<\/li>\n<li>Tv\u00e5 usb 3.0-portar;<\/li>\n<li>Integrerat 2-portars Intel x550 10Gb BASE-T n\u00e4tverkskort;<\/li>\n<li>Valfri mLOM-kort, Cisco Vic 1387 tv\u00e5portarsadapter p\u00e5 40 GB.<\/li>\n<\/ul>\n<p>\nI mLOM-slot kan endast installeras Cisco VIC-kort, som \u00e4r effektiva f\u00f6r b\u00e5de LAN och SAN trafik. N\u00e4r servern anv\u00e4nds i en Cisco UCS-fabrik m\u00f6jligg\u00f6r detta en enhetlig anslutning till LAN- och SAN-n\u00e4tverk utan behov av en separat fc-adapter. <\/p>\n<p>L\u00e5t oss installera Nvidia V100-grafikprocessorn. Ta bort den andra risern, ta bort skyddet, s\u00e4tt in kortet i PCI-slot, st\u00e4ng plasten och sedan skyddet. Anslut extra str\u00f6m. F\u00f6rst till kortet, sedan till risern. S\u00e4tt tillbaka risern. \u00d6verlag g\u00e5r det snabbt och enkelt utan skruvmejslar och hammar.<\/p>\n<p>I ett av de kommande materialen kommer vi att visa dess initiala installation. <\/p>\n<p>Vi \u00e4r ocks\u00e5 redo att svara p\u00e5 alla fr\u00e5gor <noindex><a rel=\"nofollow\" href=\"https:\/\/itglobal.com\/ru-ru\/solutions\/tech-partners\/cisco\/servers-unified-computing-system-ucs\/\">h\u00e4r<\/a><\/noindex> eller i kommentarerna.<br \/>\n<br \/>K\u00e4lla: <a content=\"nofollow\" rel=\"nofollow\" href=\"https:\/\/habr.com\/ru\/company\/itglobalcom\/blog\/467981\/\">habr.com<\/a><\/p>","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435? \u0412\u043e-\u043f\u0435\u0440\u0432\u044b\u0445, \u0441\u0435\u0440\u0432\u0435\u0440\u044b Cisco \u0442\u0435\u043f\u0435\u0440\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u0432 Intel Scalable \u0432\u0442\u043e\u0440\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0412\u043e-\u0432\u0442\u043e\u0440\u044b\u0445, \u0442\u0435\u043f\u0435\u0440\u044c \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043c\u043e\u0434\u0443\u043b\u0438 Optane Memory \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u0430 NVMe-\u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439. [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":1,"featured_media":28746,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[688],"tags":[],"class_list":["post-38294","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-administrirovanie"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Yuri Gagarin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/prohoster.info\/sv\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"sv_SE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster\" \/>\n\t\t<meta property=\"og:description\" content=\"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/prohoster.info\/sv\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2019-10-31T19:22:48+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/prohoster\" \/>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\ud83e\udd47Unboxing av rackservern Cisco UCS C240 M5 | ProHoster","description":"Idag har vi en ny rackserver, Cisco UCS C240, i femte generationen p\u00e5 v\u00e5rt bord. Vad g\u00f6r just denna Cisco-server intressant f\u00f6r unboxing, med tanke p\u00e5 att vi nu ser dess femte generation?","canonical_url":"https:\/\/prohoster.info\/sv\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":null,"og:locale":"sv_SE","og:site_name":"ProHoster | \u041a\u0443\u043f\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0445\u043e\u0441\u0442\u0438\u043d\u0433 \u0434\u043b\u044f \u0441\u0430\u0439\u0442\u043e\u0432 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 DDoS, VPS VDS \u0441\u0435\u0440\u0432\u0435\u0440\u044b","og:type":"article","og:title":"\ud83e\udd47\u0410\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433 \u0441\u0442\u043e\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0435\u0440\u0430 Cisco UCS C240 M5 | ProHoster","og:description":"\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0443 \u043d\u0430\u0441 \u043d\u0430 \u0441\u0442\u043e\u043b\u0435 \u043d\u043e\u0432\u044b\u0439 \u0440\u044d\u043a\u043e\u0432\u044b\u0439 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco UCS C240 \u043f\u044f\u0442\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u044f. \u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u043c \u0434\u043b\u044f \u0430\u043d\u0431\u043e\u043a\u0441\u0438\u043d\u0433\u0430 \u0438\u043c\u0435\u043d\u043d\u043e \u044d\u0442\u043e\u0442 \u0441\u0435\u0440\u0432\u0435\u0440 Cisco, \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u043c\u0438 \u0443\u0436\u0435 \u0435\u0433\u043e \u043f\u044f\u0442\u043e\u0435 \u043f\u043e\u043a\u043e\u043b\u0435\u043d\u0438\u0435?","og:url":"https:\/\/prohoster.info\/sv\/blog\/administrirovanie\/anboksing-stoechnogo-servera-cisco-ucs-c240-m5","og:image":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:secure_url":"https:\/\/prohoster.info\/wp-content\/uploads\/2021\/11\/logo-350.jpg","og:image:width":350,"og:image:height":350,"article:published_time":"2019-10-31T19:22:48+00:00","article:modified_time":"2019-10-31T19:22:48+00:00","article:publisher":"https:\/\/www.facebook.com\/prohoster","article:author":"https:\/\/www.facebook.com\/prohoster"},"aioseo_meta_data":{"post_id":"38294","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-02-09 13:06:19","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"ai":null,"created":"2021-03-01 01:12:21","updated":"2026-02-09 13:06:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/posts\/38294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/comments?post=38294"}],"version-history":[{"count":1,"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/posts\/38294\/revisions"}],"predecessor-version":[{"id":158206,"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/posts\/38294\/revisions\/158206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/media\/28746"}],"wp:attachment":[{"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/media?parent=38294"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/categories?post=38294"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prohoster.info\/sv\/wp-json\/wp\/v2\/tags?post=38294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}