Ceph - ukusuka "edolweni" ukuya "kwimveliso"

Ukukhetha CEPH. Icandelo loku-1

Sasinama-racks amahlanu, i-optical switches ezilishumi, i-BGP elungisiweyo, isibini se-SSD kunye neqela leediski ze-SAS zayo yonke imibala kunye nobukhulu, kunye ne-proxmox kunye nomnqweno wokubeka yonke idatha engatshintshiyo kwisitoreji sethu se-S3. Ayikuko ukuba yonke le nto iyafuneka kwi-virtualization, kodwa nje ukuba uqale ukusebenzisa i-opensource, landela into oyithandayo kude kube sekupheleni. Eyonanto ibindikhathaza yiBGP. Akukho mntu ehlabathini ongenakuzinceda, ongakhathaliyo noziphethe kakubi ngaphezu kwendlela ye-BGP yangaphakathi. Kwaye bendisazi ukuba kungekudala sizakuntywila kuyo.

Ceph - ukusuka "edolweni" ukuya "kwimveliso"

Umsebenzi wawungabalulekanga - kwakukho i-CEPH, kodwa ayizange isebenze kakuhle. Kwakuyimfuneko ukwenza "okulungileyo".
Iqela endilifumeneyo lalilixakeke kakhulu, licudiswe ngokukhawuleza kwaye alilungiswanga. Yayibandakanya amaqela amabini eendawo ezahlukeneyo, kunye negridi enye eqhelekileyo esebenza njengeqela kunye nenethiwekhi yoluntu. Iingqungquthela zazaliswa ngeentlobo ezine zeediski - iintlobo ezimbini ze-SSD, eziqokelelwe kwimigaqo emibini yokubeka eyahlukileyo, kunye neentlobo ezimbini ze-HDD zobukhulu obuhlukeneyo, eziqokelelwe kwiqela lesithathu. Ingxaki enobungakanani obahlukeneyo yasonjululwa bubunzima obahlukeneyo beOSD.

Ukuseta ngokwalo kwahlulwe yangamacandelo amabini - ukulungiswa kwenkqubo yokusebenza и ukulungiswa kweCEPH ngokwayo kunye nezicwangciso zayo.

Ukuphucula i-OS

womnatha

Ukubambezeleka okuphezulu kuchaphazele zombini ukurekhoda kunye nokulinganisa. Xa urekhoda - kuba umxhasi akayi kufumana impendulo malunga nokurekhoda okuyimpumelelo de i-replicas yedatha kwamanye amaqela okubeka iqinisekisa impumelelo. Ukusukela ukuba imigaqo yokusasaza iikopi kwimephu ye-CRUSH yayiyi-replica enye kumamkeli ngamnye, inethiwekhi yayisoloko isetyenziswa.

Ke ngoko, into yokuqala endigqibe kwelokuba ndiyenze kukutsala kancinci inethiwekhi yangoku, ngelixa kwangaxeshanye ndizama ukundiqinisekisa ukuba ndiye kuthungelwano olwahlukileyo.

Ukuqala, nditshintshe useto lwamakhadi enethiwekhi. Ndiqale ngokuseta imigca:

kweneke ntoni:

i-ethtool -l ens1f1

root@ceph01:~# ethtool -l ens1f1
Channel parameters for ens1f1:
Pre-set maximums:
RX:     0
TX:     0
Other:      1
Combined:   63
Current hardware settings:
RX:     0
TX:     0
Other:      1
Combined:   1
root@ceph01:~# ethtool -g ens1f1
Ring parameters for ens1f1:
Pre-set maximums:
RX:     4096
RX Mini:    0
RX Jumbo:   0
TX:     4096
Current hardware settings:
RX:     256
RX Mini:    0
RX Jumbo:   0
TX:     256
root@ceph01:~# ethtool -l ens1f1
Channel parameters for ens1f1:
Pre-set maximums:
RX:     0
TX:     0
Other:      1
Combined:   63
Current hardware settings:
RX:     0
TX:     0
Other:      1
Combined:   1

Inokubonwa ukuba iiparameters zangoku zikude kwi-maximus. Yandisiwe:

root@ceph01:~#ethtool -G ens1f0 rx 4096
root@ceph01:~#ethtool -G ens1f0 tx 4096
root@ceph01:~#ethtool -L ens1f0 combined 63

Ikhokelwa linqaku eligqwesileyo

https://blog.packagecloud.io/eng/2017/02/06/monitoring-tuning-linux-networking-stack-sending-data/

kwandisa ubude bomgca wokuthumela txqueuelen ukusuka kwi-1000 ukuya kwi-10

root@ceph01:~#ip link set ens1f0  txqueuelen 10000

Ewe, kulandela uxwebhu lwe-ceph ngokwayo

https://ceph.com/geen-categorie/ceph-loves-jumbo-frames/

anda UMNTU ukuya kwi-9000.

root@ceph01:~#ip link set dev ens1f0  mtu 9000

Yongezwe kwi /etc/network/interfaces ukuze zonke ezi zingentla zilayishwe ekuqaleni

ikati / njl / inethiwekhi / ujongano

root@ceph01:~# cat /etc/network/interfaces
auto lo
iface lo inet loopback

auto ens1f0
iface ens1f0 inet manual
post-up /sbin/ethtool -G ens1f0 rx 4096
post-up /sbin/ethtool -G ens1f0 tx 4096
post-up /sbin/ethtool -L ens1f0 combined 63
post-up /sbin/ip link set ens1f0  txqueuelen 10000
mtu 9000

auto ens1f1
iface ens1f1 inet manual
post-up /sbin/ethtool -G ens1f1 rx 4096
post-up /sbin/ethtool -G ens1f1 tx 4096
post-up /sbin/ethtool -L ens1f1 combined 63
post-up /sbin/ip link set ens1f1  txqueuelen 10000
mtu 9000

Emva koko, ngokulandela inqaku elifanayo, ndaqala ukucinga ngokujija izibambo ze-4.15 kernel. Ukuqwalasela ukuba ii-nodes zine-RAM ye-128G, siphelile ngefayile yoqwalaselo sysctl

ikati /etc/sysctl.d/50-ceph.conf

net.core.rmem_max = 56623104  
#Максимальный размер буфера приема данных для всех соединений  54M

net.core.wmem_max = 56623104
#Максимальный размер буфера передачи данных для всех соединений 54M

net.core.rmem_default = 56623104
#Размер буфера приема данных по умолчанию для всех соединений. 54M

net.core.wmem_default = 56623104
#Размер буфера передачи данных по умолчанию для всех соединений 54M  
# на каждый сокет

net.ipv4.tcp_rmem = 4096 87380 56623104
#Векторная (минимум, по умолчанию, максимум) переменная в файле tcp_rmem
# содержит 3 целых числа, определяющих размер приемного буфера сокетов TCP.
# Минимум: каждый сокет TCP имеет право использовать эту память по 
# факту своего создания. Возможность использования такого буфера 
# гарантируется даже при достижении порога ограничения (moderate memory pressure).
# Размер минимального буфера по умолчанию составляет 8 Кбайт (8192).
#Значение по умолчанию: количество памяти, допустимое для буфера 
# передачи сокета TCP по умолчанию. Это значение применяется взамен
# параметра /proc/sys/net/core/rmem_default, используемого другими протоколами.
# Значение используемого по умолчанию буфера обычно (по умолчанию) 
# составляет 87830 байт. Это определяет размер окна 65535 с 
# заданным по умолчанию значением tcp_adv_win_scale и tcp_app_win = 0, 
# несколько меньший, нежели определяет принятое по умолчанию значение tcp_app_win.
# Максимум: максимальный размер буфера, который может быть автоматически
# выделен для приема сокету TCP. Это значение не отменяет максимума, 
# заданного в файле /proc/sys/net/core/rmem_max. При «статическом»
# выделении памяти с помощью SO_RCVBUF этот параметр не имеет значения.

net.ipv4.tcp_wmem = 4096 65536 56623104
net.core.somaxconn = 5000    
# Максимальное число открытых сокетов, ждущих соединения.

net.ipv4.tcp_timestamps=1
# Разрешает использование временных меток (timestamps), в соответствии с RFC 1323.

net.ipv4.tcp_sack=1
# Разрешить выборочные подтверждения протокола TCP

net.core.netdev_max_backlog=5000 (дефолт 1000)
# максимальное количество пакетов в очереди на обработку, если 
# интерфейс получает пакеты быстрее, чем ядро может их обработать.

net.ipv4.tcp_max_tw_buckets=262144
# Максимальное число сокетов, находящихся в состоянии TIME-WAIT одновременно.
# При превышении этого порога – «лишний» сокет разрушается и пишется
# сообщение в системный журнал.

net.ipv4.tcp_tw_reuse=1
#Разрешаем повторное использование TIME-WAIT сокетов в случаях,
# если протокол считает это безопасным.

net.core.optmem_max=4194304
#Увеличить максимальный общий буфер-космической ALLOCATABLE
#измеряется в единицах страниц (4096 байт)

net.ipv4.tcp_low_latency=1
#Разрешает стеку TCP/IP отдавать предпочтение низкому времени ожидания
# перед более высокой пропускной способностью.

net.ipv4.tcp_adv_win_scale=1
# Эта переменная влияет на вычисление объема памяти в буфере сокета,
# выделяемой под размер TCP-окна и под буфер приложения.
# Если величина tcp_adv_win_scale отрицательная, то для вычисления размера
# используется следующее выражение:
# Bytes- bytes2в степени -tcp_adv_win_scale
# Где bytes – это размер окна в байтах. Если величина tcp_adv_win_scale
# положительная, то для определения размера используется следующее выражение:
# Bytes- bytes2в степени tcp_adv_win_scale
# Переменная принимает целое значение. Значение по-умолчанию – 2, 
# т.е. под буфер приложения отводится ¼ часть объема, определяемого переменной
# tcp_rmem.

net.ipv4.tcp_slow_start_after_idle=0
# механизм перезапуска медленного старта, который сбрасывает значение окна 
# перегрузки, если соединение не использовалось заданный период времени.
# Лучше отключить SSR на сервере, чтобы улучшить производительность 
# долгоживущих соединений.

net.ipv4.tcp_no_metrics_save=1
#Не сохранять результаты измерений TCP соединения в кеше при его закрытии.

net.ipv4.tcp_syncookies=0
#Отключить механизм отправки syncookie

net.ipv4.tcp_ecn=0
#Explicit Congestion Notification (Явное Уведомление о Перегруженности) в 
# TCP-соединениях. Используется для уведомления о возникновении «затора» 
# на маршруте к заданному хосту или сети. Может использоваться для извещения
# хоста-отправителя о необходимости снизить скорость передачи пакетов через
# конкретный маршрутизатор или брандмауэр.

net.ipv4.conf.all.send_redirects=0
# выключает выдачу ICMP Redirect … другим хостам. Эта опция обязательно
# должна быть включена, если хост выступает в роли маршрутизатора любого рода.
# У нас нет маршрутизации.

net.ipv4.ip_forward=0
#Сопсно отключение форвардинга. Мы не шлюз, докер на машинах не поднят,
# нам это не нужно.

net.ipv4.icmp_echo_ignore_broadcasts=1
#Не отвечаем на ICMP ECHO запросы, переданные широковещательными пакетами

net.ipv4.tcp_fin_timeout=10
#определяет время сохранения сокета в состоянии FIN-WAIT-2 после его
# закрытия локальной стороной. Дефолт 60

net.core.netdev_budget=600 # (дефолт 300)
# Если выполнение программных прерываний не выполняются достаточно долго,
# то темп роста входящих данных может превысить возможность ядра 
# опустошить буфер. В результате буферы NIC переполнятся, и трафик будет потерян.
# Иногда, необходимо увеличить длительность работы SoftIRQs
# (программных прерываний) с CPU. За это отвечает netdev_budget. 
# Значение по умолчанию 300. Параметр заставит процесс SoftIRQ обработать
# 300 пакетов от NIC перед тем как отпустить CPU

net.ipv4.tcp_fastopen=3
# TFO TCP Fast Open
# если и клиент и сервер имеют поддержку TFO, о которой сообщают за счет
# специального флага в TCP пакете. В нашем случае является плацебо, просто
# выглядит красиво)

Сluster network yabelwa kwiindawo ezahlukeneyo zenethiwekhi ye-10Gbps kwinethiwekhi eyahlukileyo. Umatshini ngamnye wawuxhotyiswe ngamakhadi womnatha anezibuko ezimbini i-mellanox I-10/25 Gbps, ifakwe kwizitshixo ezimbini ezahlukeneyo ze-10Gbps. Udibaniso lwenziwa kusetyenziswa i-OSPF, ekubeni ukudibanisa kunye ne-lacp ngesizathu esithile kubonise ukugqithisa okupheleleyo kwe-16 Gbps, ngelixa i-ospf isebenzise ngempumelelo zombini amashumi kumatshini ngamnye. Izicwangciso zexesha elizayo yayikukusebenzisa i-ROCE kwezi melanoxes ukunciphisa i-latency. Iseta njani le ndawo yothungelwano:

  1. Ekubeni oomatshini ngokwabo bangaphandle iidilesi IP kwi BGP, sifuna software - (ngokuchanekileyo, ngexesha lokubhalwa kweli nqaku frr=6.0-1 ) wayesele emile.
  2. Lilonke, oomatshini babenonxibelelwano lwenethiwekhi ezimbini, nganye ineendlela ezimbini zokujongana - iyonke yamachweba ama-4. Ikhadi elinye lomnatha lijonge kumzi-mveliso kunye namazibuko amabini kwaye i-BGP iqwalaselwe kuyo, eyesibini yajonga iiswitshi ezimbini ezahlukeneyo kunye namazibuko amabini kunye ne-OSPF ebekwe kuyo.

Iinkcukacha ezithe kratya ngokuseta i-OSPF: Owona msebenzi uphambili kukuhlanganisa amakhonkco amabini kwaye ube nokunyamezelana iimpazamo.
ujongano lwenethiwekhi ezimbini ziqwalaselwe zibe ziinethiwekhi ezimbini ezilula caba - 10.10.10.0/24 kunye 10.10.20.0/24

1: ens1f0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 9000 qdisc mq state UP group default qlen 1000
    inet 10.10.10.2/24 brd 10.10.10.255 scope global ens1f0

2: ens1f1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 9000 qdisc mq state UP group default qlen 1000
    inet 10.10.20.2/24 brd 10.10.20.255 scope global ens1f1

apho iimoto zibonana ngazo.

IDISKI

Inyathelo elilandelayo ibikukwandisa iidiski. Kwi-SSD nditshintshe umcwangcisi ukuba hayi, yeHDD - umhla wokugqibela. Ukuyibeka ngokucacileyo, i-NOOP isebenza kumgaqo "wokuqala ukungena, kuqala," othi ngesiNgesi uvakala ngathi "FIFO (First In, First Out)." Izicelo zibekwe emgceni xa zifika. I-DEADLINE ijolise ekufundeni ngakumbi, kunye nenkqubo esemgceni ifumana ufikelelo olukhethekileyo kwidiski ngexesha lomsebenzi. Oku kugqibelele kwinkqubo yethu - emva kwayo yonke loo nto, inkqubo enye kuphela isebenza ngediski nganye - i-OSD daemon.
(Abo bafuna ukuntywila kwi-I/O scheduler banokufunda ngayo apha:
http://www.admin-magazine.com/HPC/Articles/Linux-I-O-Schedulers

Abo bakhetha ukufunda ngesiRashiya: https://www.opennet.ru/base/sys/linux_shedulers.txt.html)

Kwizindululo zokulungisa iLinux, kuyacetyiswa ukuba unyuse i-nr_request

nr_izicelo
Ixabiso le-nr_requests limisela inani lezicelo ze-I / O ezifumana i-buffer phambi kokuba umcwangcisi we-I / O athumele / afumane idatha kwisixhobo sebhlokhi, ukuba usebenzisa ikhadi le-RAID / Icebo leBlock elinokusingatha umgca omkhulu kunoko I /O umcwangcisi usetelwe ku, ukuphakamisa ixabiso le-nr_requests kunokunceda ukuphucula yonke indawo kunye nokunciphisa umthwalo womncedisi xa izixa ezikhulu ze-I/O zenzeka kumncedisi. Ukuba usebenzisa uMhla wokugqibela okanye iCFQ njengomcwangcisi, kuyacetyiswa ukuba ucwangcise ixabiso le-nr_request ukuya kumaxesha ama-2 exabiso lobunzulu bomgca.

KODWA! Abemi ngokwabo, abaphuhlisi be-CEPH, bayasiqinisekisa ukuba inkqubo yabo yezinto eziphambili zisebenza ngcono

Ceph - ukusuka "edolweni" ukuya "kwimveliso"

I-WBTthrottle kunye/okanye i-nr_requests

I-WBTthrottle kunye/okanye i-nr_requests
Ugcino lweefayile lusebenzisa imisebenzi ye-I/O efakwe i-buffered yokubhala; oku kunika iingenelo ezininzi ukuba ijenali yokugcina iifayile ikwimidiya ekhawulezayo. Izicelo zabathengi ziyaziswa kwangoko emva kokuba idatha ibhaliwe kwijenali, ize ithunyelwe kwidiski yedatha kamva kusetyenziswa umsebenzi oqhelekileyo. LinuxOku kwenza kube nokwenzeka ukuba ii-OSD spindle drives zibonelele ngokubhala okufana nee-SSD xa zibhala kwiipakethi ezincinci. Oku kubhala okulibazisekileyo kukwavumela i-kernel ngokwayo ukuba ihlengahlengise izicelo ze-I/O kwidiski, inethemba lokuba ziya kuzidibanisa kunye okanye zivumele iintloko zediski ukuba zikhethe indlela efanelekileyo kwiiplati zazo. Isiphumo sokugqibela kukuba ungacinezela kancinci imisebenzi ye-I/O kwidiski nganye kunokuba kunokwenzeka ngemisebenzi ye-I/O ethe ngqo okanye ehambelanayo.

Nangona kunjalo, ingxaki ethile ivela ukuba umthamo weerekhodi ezingenayo kwiqela le-Ceph elinikeziweyo lidlula zonke izakhono zeediski eziphantsi. Kule meko, inani elipheleleyo lemisebenzi ye-I / O elindele ukubhalwa kwidiski inokukhula ngokungalawulekiyo kwaye ibangele umgca we-I / O ugcwalise yonke idiski kunye ne-Ceph queues. Izicelo zokufunda zichaphazeleka ngakumbi kuba zixinga phakathi kwezicelo zokubhala, ezinokuthatha imizuzwana emininzi ukugungxula kwidiski engundoqo.

Ukoyisa le ngxaki, uCeph unendlela yokubhala umva eyakhiwe kwindawo yokugcina ifayile ebizwa ngokuba yiWBThrottle. Yenzelwe ukunciphisa inani elipheleleyo lokubhala i-I/O enokufola kwaye iqale inkqubo yayo yokugungxula kwangethuba kunokuba bekuya kwenzeka ngokwendalo ngenxa yokwenziwa isebenze yikernel ngokwayo. Ngelishwa, uvavanyo lubonisa ukuba amaxabiso angagqibekanga asenokunciphisa indlela yokuziphatha ekhoyo ukuya kwinqanaba elinokunciphisa le mpembelelo ekufundeni ukubambezeleka. Ulungelelwaniso lungayitshintsha le ndlela yokuziphatha kwaye lunciphise ubude bomgca wokubhala kwaye yenze le mpembelelo ibe mbi kakhulu. Kukho ukurhweba, nangona kunjalo: ngokunciphisa inani eliphezulu elipheleleyo lamangeno avunyelwe ukuba afakwe emgceni, unokunciphisa amandla e-kernel ngokwawo ukwandisa ukusebenza kwayo ekulandeleni izicelo ezingenayo. Kuyafaneleka ukuba ucinge kancinci malunga nento oyifunayo ngakumbi kwimeko yakho yokusetyenziswa, umthwalo womsebenzi kunye nohlengahlengiso ukuze ulungele bona.

Ukulawula ubunzulu boluhlu olunjalo lokubhala-backlog, unganciphisa inani eliphezulu elipheleleyo lemisebenzi ye-I/O ebalaseleyo usebenzisa i-WBThrottle useto, okanye unokunciphisa ixabiso eliphezulu lemisebenzi ebalaseleyo kwinqanaba lebhloko yekernel yakho ngokwayo. Bobabini banokulawula ngokufanelekileyo ukuziphatha okufanayo, kwaye ukhetho lwakho luya kuba sisiseko sokuphumeza olu cwangciso.
Kufuneka kwakhona kuqatshelwe ukuba inkqubo ye-Ceph ephambili isebenza kakuhle kwimibuzo emifutshane kwinqanaba lediski. Ngokucutha umgca opheleleyo kwidiski enikiweyo, indawo ephambili yomgca ifudukela eCeph, apho inolawulo olungaphezulu malunga nokuba yintoni ephambili umsebenzi we-I/O. Qwalasela lo mzekelo ulandelayo:

echo 8 > /sys/block/sda/queue/nr_requests

http://onreader.mdl.ru/MasteringCeph/content/Ch09.html#030202

I-COMMON

Kwaye ezinye ii-tweaks ezimbalwa ze-kernel ukwenza imoto yakho ithambe kwaye ibe silky kwaye icudise ukusebenza kancinci kwi-hardware.

ikati /etc/sysctl.d/60-ceph2.conf

 kernel.pid_max = 4194303
#Дисков в каждой машине по 25, потому рассчитывали что процессов будет много
kernel.threads-max=2097152
# Тредов, естессно, тоже.
vm.max_map_count=524288
# Увеличили количество областей карты памяти процесса. 
# Как следует из документации по ядерным переменным 
# Области карты памяти используется как побочный эффект вызова
# malloc, напрямую с помощью mmap, mprotect и madvise, а также при загрузке
# общих библиотек.
fs.aio-max-nr=50000000
# Подтюним параметры input-output
# Ядро Linux предоставляет функцию асинхронного неблокирующего ввода-вывода (AIO),
# которая позволяет процессу инициировать несколько операций ввода-вывода
# одновременно, не дожидаясь завершения какой-либо из них. 
# Это помогает повысить производительность приложений, 
# которые могут перекрывать обработку и ввод-вывод.
# Параметр aio-max-nr определяет максимальное количество допустимых 
# одновременных запросов.
vm.min_free_kbytes=1048576
# минимальный размер свободной памяти который необходимо поддерживать.
# Выставлен 1Gb, чего вполне достаточно для работы операционной системы, 
# и позволяет избегать OOM Killer для процессов OSD. Хотя памяти и так
# как у дурака фантиков, но запас карман не тянет
vm.swappiness=10
# Говорим использовать своп если осталось свободным 10% памяти.
# На машинах 128G оперативы, и 10% это 12 Гигов. Более чем достаточно для работы.
# Штатный параметр в 60% заставлял тормозить систему, залезая в своп,
# когда есть еще куча свободной памяти
vm.vfs_cache_pressure=1000
# Увеличиваем со штатных 100. Заставляем ядро активнее выгружать
# неиспользуемые страницы памяти из кеша.
vm.zone_reclaim_mode=0
# Позволяет  устанавливать более или менее агрессивные подходы к
# восстановлению памяти, когда в зоне заканчивается память. 
# Если он установлен на ноль, то не происходит восстановление зоны.
# Для файловых серверов или рабочих нагрузок
# выгодно, если их данные кэшированы, zone_reclaim_mode
# оставить отключенным, поскольку эффект кэширования, 
# вероятно, будет более важным, чем местонахождение данных.
vm.dirty_ratio=20
# Процент оперативной памяти, который можно выделить под "грязные" страницы
# Вычисляли из примерного расчета: 
# В система 128 гигов памяти.
# Примерно по 20 дисков SSD, у которых в настройках CEPH указано 
# выделять под кэширование по 3G оперативы.
# Примерно по 40 дисков HDD, для которых этот параметр равен 1G
# 20% от 128 это 25.6 гигов. Итого, в случае максимальной утилизации памяти,
# для системы останется 2.4G памяти. Чего ей должно хватить чтоб выжить и дождаться
# стука копыт кавалерии - то есть пришествия DevOps который все починит.
vm.dirty_background_ratio=3
# процент системной памяти, который можно заполнить dirty pages до того,
# как фоновые процессы pdflush/flush/kdmflush запишут их на диск
fs.file-max=524288
# Ну и открытых файлов у нас,вероятно, будет сильно больше, чем указано по дефолту. 

Ukuntywiliselwa kwi-CEPH

Iisetingi endifuna ukuhlala kuzo ngokweenkcukacha ezithe vetshe:

ikati /etc/ceph/ceph.conf

osd:
    journal_aio: true               # Три параметра, включающие 
    journal_block_align: true       # прямой i/o
    journal_dio: true               # на журнал
    journal_max_write_bytes: 1073714824 # Немного растянем максимальный размер
                                        # разово записываемой операции в журнал
    journal_max_write_entries: 10000    # Ну и количество одновременных записей
    journal_queue_max_bytes: 10485760000 
    journal_queue_max_ops: 50000
    rocksdb_separate_wal_dir: true      # Решили делать отдельный wal                                                                            
                                        # Даже попытались выбить под это дело                                                                                                                                                                                     
                                        # NVMe
    bluestore_block_db_create: true     # Ну и под журнал отдельное устройство
    bluestore_block_db_size: '5368709120 #5G'
    bluestore_block_wal_create: true
    bluestore_block_wal_size: '1073741824   #1G' 
    bluestore_cache_size_hdd: '3221225472   # 3G' 
                                            # большой объем оперативы позволяет 
                                            # хранить достаточно большие объемы
    bluestore_cache_size_ssd: '9663676416   # 9G' 

    keyring: /var/lib/ceph/osd/ceph-$id/keyring
    osd_client_message_size_cap: '1073741824 #1G'
    osd_disk_thread_ioprio_class: idle
    osd_disk_thread_ioprio_priority: 7
    osd_disk_threads: 2 # количество тредов у демона на один диск
    osd_failsafe_full_ratio: 0.95
    osd_heartbeat_grace: 5
    osd_heartbeat_interval: 3
    osd_map_dedup: true
    osd_max_backfills: 2 # количество одновременных операций заполнения на один ОСД.
    osd_max_write_size: 256
    osd_mon_heartbeat_interval: 5
    osd_op_threads: 16
    osd_op_num_threads_per_shard: 1
    osd_op_num_threads_per_shard_hdd: 2
    osd_op_num_threads_per_shard_ssd: 2
    osd_pool_default_min_size: 1     # Особенности жадности. Очень быстро стало
    osd_pool_default_size: 2         # нехватать места, потому как временное                                                                                                                                                      
                                     # решение приняли уменьшение количество 
                                     # реплик данных
    osd_recovery_delay_start: 10.000000
    osd_recovery_max_active: 2
    osd_recovery_max_chunk: 1048576
    osd_recovery_max_single_start: 3
    osd_recovery_op_priority: 1
    osd_recovery_priority: 1            # параметр регулируем по необходимости на ходу
    osd_recovery_sleep: 2
    osd_scrub_chunk_max: 4

Ezinye zeeparamitha ezivavanyelwe i-QA kwinguqulo 12.2.12 azikho kwi-ceph version 12.2.2, umzekelo. osd_recovery_threads. Ngoko ke, izicwangciso zibandakanya ukuhlaziywa kwimveliso kwi-12.2.12. Ukuziqhelanisa kubonise ukuhambelana phakathi kweenguqulelo ze-12.2.2 kunye ne-12.2.12 kwiqela elinye, elivumela ukuhlaziywa.

Iqela lovavanyo

Ngokwemvelo, ukuvavanya kwakuyimfuneko ukuba kubekho inguqu efanayo njengasedabini, kodwa ngexesha ndaqalisa ukusebenza kunye neqela, kuphela entsha yayifumaneka kwindawo yokugcina. Xa ujongile, into onokuyibona kwinguqulelo encinci ayinkulu kakhulu (1393 imigca kuqwalaselo 1436 kuguqulelo olutsha), sigqibe kwelokuba siqale ukuvavanya entsha (ukuhlaziya kunjalo, kutheni uhamba nenkunkuma endala)

Ekuphela kwento esazama ukuyishiya ngasemva inguqulelo endala yiphakheji ceph-deploy kuba ezinye zezinto eziluncedo (kunye nabanye babasebenzi) zilungelelaniswe ngokwesintaksi yayo. Inguqulelo entsha yayahluke kakhulu, kodwa ayizange ichaphazele ukusebenza kweqela ngokwalo, kwaye yayishiywe kwinguqulelo 1.5.39

Ekubeni umyalelo we-ceph-disk uthi ngokucacileyo ukuba iyancipha kwaye isebenzise umyalelo we-ceph-volume, zintanda, siqale ukudala ii-OSD ngalo myalelo, ngaphandle kokuchitha ixesha kwizinto eziphelelwe lixesha.

Isicwangciso yayikukudala isibuko se-SSD ezimbini zokuqhuba apho siya kubeka khona iilogi ze-OSD, ezithi, zona, zibekwe kwi-spindle SASs. Ngale ndlela sinokuzikhusela kwiingxaki ngedatha ukuba idiski enelogi iyawa.

Saqala ukwenza i-cluster ngokuhambelana namaxwebhu

ikati /etc/ceph/ceph.conf

root@ceph01-qa:~# cat /etc/ceph/ceph.conf # положили заранее подготовленный конфиг
[client]
rbd_cache = true
rbd_cache_max_dirty = 50331648
rbd_cache_max_dirty_age = 2
rbd_cache_size = 67108864
rbd_cache_target_dirty = 33554432
rbd_cache_writethrough_until_flush = true
rbd_concurrent_management_ops = 10
rbd_default_format = 2
[global]
auth_client_required = cephx
auth_cluster_required = cephx
auth_service_required = cephx
cluster network = 10.10.10.0/24
debug_asok = 0/0
debug_auth = 0/0
debug_buffer = 0/0
debug_client = 0/0
debug_context = 0/0
debug_crush = 0/0
debug_filer = 0/0
debug_filestore = 0/0
debug_finisher = 0/0
debug_heartbeatmap = 0/0
debug_journal = 0/0
debug_journaler = 0/0
debug_lockdep = 0/0
debug_mon = 0/0
debug_monc = 0/0
debug_ms = 0/0
debug_objclass = 0/0
debug_objectcatcher = 0/0
debug_objecter = 0/0
debug_optracker = 0/0
debug_osd = 0/0
debug_paxos = 0/0
debug_perfcounter = 0/0
debug_rados = 0/0
debug_rbd = 0/0
debug_rgw = 0/0
debug_throttle = 0/0
debug_timer = 0/0
debug_tp = 0/0
fsid = d0000000d-4000-4b00-b00b-0123qwe123qwf9
mon_host = ceph01-q, ceph02-q, ceph03-q
mon_initial_members = ceph01-q, ceph02-q, ceph03-q
public network = 8.8.8.8/28 # адрес изменен, естественно ))
rgw_dns_name = s3-qa.mycompany.ru # и этот адрес измен
rgw_host = s3-qa.mycompany.ru # и этот тоже
[mon]
mon allow pool delete = true
mon_max_pg_per_osd = 300 # больше трехсот плейсмент групп
                          # на диск не решились
                     # хотя параметр, естественно, зависит от количества пулов,
                     # их размеров и количества OSD. Иметь мало но здоровых PG
                        # тоже не лучший выбор - страдает точность балансировки
mon_osd_backfillfull_ratio = 0.9
mon_osd_down_out_interval = 5
mon_osd_full_ratio = 0.95 # пока для SSD дисков местом для их
                          # журнала является тот-же девайс что и для ОСД
                          # решили что 5% от диска (который сам размером 1.2Tb)
                          #  должно вполне хватить, и коррелирует с параметром
                          # bluestore_block_db_size плюс вариативность на большие 
                          # плейсмент группы
mon_osd_nearfull_ratio = 0.9
mon_pg_warn_max_per_osd = 520
[osd]
bluestore_block_db_create = true
bluestore_block_db_size = 5368709120 #5G
bluestore_block_wal_create = true
bluestore_block_wal_size = 1073741824 #1G
bluestore_cache_size_hdd = 3221225472 # 3G
bluestore_cache_size_ssd = 9663676416 # 9G
journal_aio = true
journal_block_align = true
journal_dio = true
journal_max_write_bytes = 1073714824
journal_max_write_entries = 10000
journal_queue_max_bytes = 10485760000
journal_queue_max_ops = 50000
keyring = /var/lib/ceph/osd/ceph-$id/keyring
osd_client_message_size_cap = 1073741824 #1G
osd_disk_thread_ioprio_class = idle
osd_disk_thread_ioprio_priority = 7
osd_disk_threads = 2
osd_failsafe_full_ratio = 0.95
osd_heartbeat_grace = 5
osd_heartbeat_interval = 3
osd_map_dedup = true
osd_max_backfills = 4
osd_max_write_size = 256
osd_mon_heartbeat_interval = 5
osd_op_num_threads_per_shard = 1
osd_op_num_threads_per_shard_hdd = 2
osd_op_num_threads_per_shard_ssd = 2
osd_op_threads = 16
osd_pool_default_min_size = 1
osd_pool_default_size = 2
osd_recovery_delay_start = 10.0
osd_recovery_max_active = 1
osd_recovery_max_chunk = 1048576
osd_recovery_max_single_start = 3
osd_recovery_op_priority = 1
osd_recovery_priority = 1
osd_recovery_sleep = 2
osd_scrub_chunk_max = 4
osd_scrub_chunk_min = 2
osd_scrub_sleep = 0.1
rocksdb_separate_wal_dir = true

# создаем мониторы
root@ceph01-qa:~#ceph-deploy mon create ceph01-q
# генерируем ключи для аутентификации нод в кластере
root@ceph01-qa:~#ceph-deploy gatherkeys ceph01-q
# Это если поштучно. Если у нас несколько машин доступны - те, которые описаны в конфиге в секции 
# mon_initial_members = ceph01-q, ceph02-q, ceph03-q
# можно запустить эти две команды в виде одной
root@ceph01-qa:~#ceph-deploy mon create-initial
# Положим ключи в указанные в конфиге места
root@ceph01-qa:~#cat ceph.bootstrap-osd.keyring > /var/lib/ceph/bootstrap-osd/ceph.keyring 
root@ceph01-qa:~#cat ceph.bootstrap-mgr.keyring > /var/lib/ceph/bootstrap-mgr/ceph.keyring 
root@ceph01-qa:~#cat ceph.bootstrap-rgw.keyring > /var/lib/ceph/bootstrap-rgw/ceph.keyring
# создадим ключ для управления кластером
root@ceph01-qa:~#ceph-deploy admin ceph01-q
# и менеджер, плагинами управлять
root@ceph01-qa:~#ceph-deploy mgr create ceph01-q

Into yokuqala endiye ndakhubeka kuyo xa ndisebenza ngolu hlobo lwe-ceph-deploy kunye nenguqulo ye-cluster 12.2.12 yayiyimpazamo xa uzama ukwenza i-OSD nge-db kuhlaselo lwesoftware -

root@ceph01-qa:~#ceph-volume lvm create --bluestore --data /dev/sde --block.db /dev/md0
blkid could not detect a PARTUUID for device: /dev/md1

Ewe, i-blkid ayibonakali ngathi yi-PARTUUID, ke kuye kwafuneka ndenze izahlulo ngesandla:

root@ceph01-qa:~#parted /dev/md0 mklabel GPT 
# разделов будет много, 
# без GPT их создать не получится
# размер раздела мы указали в конфиге выше = bluestore_block_db_size: '5368709120 #5G'
# Дисков у меня 20 под OSD, руками создавать разделы лень
# потому сделал цикл
root@ceph01-qa:~#for i in {1..20}; do echo -e "nnnn+5Gnw" | fdisk /dev/md0; done

Yonke into ibonakala ilungile, sizama ukwenza i-OSD kwakhona kwaye sifumane impazamo elandelayo (leyo, ngendlela, ayizange iveliswe edabini)

xa usenza i-OSD yohlobo lwebluestore ngaphandle kokuchaza indlela eya kwi-WAL, kodwa ichaza i-db

root@ceph01-qa:~#ceph-volume lvm create --bluestore --data /dev/sde --block.db /dev/md0
 stderr: 2019-04-12 10:39:27.211242 7eff461b6e00 -1 bluestore(/var/lib/ceph/osd/ceph-0/) _read_fsid unparsable uuid
 stderr: 2019-04-12 10:39:27.213185 7eff461b6e00 -1 bdev(0x55824c273680 /var/lib/ceph/osd/ceph-0//block.wal) open open got: (22) Invalid argument
 stderr: 2019-04-12 10:39:27.213201 7eff461b6e00 -1 bluestore(/var/lib/ceph/osd/ceph-0/) _open_db add block device(/var/lib/ceph/osd/ceph-0//block.wal) returned: (22) Invalid argument
 stderr: 2019-04-12 10:39:27.999039 7eff461b6e00 -1 bluestore(/var/lib/ceph/osd/ceph-0/) mkfs failed, (22) Invalid argument
 stderr: 2019-04-12 10:39:27.999057 7eff461b6e00 -1 OSD::mkfs: ObjectStore::mkfs failed with error (22) Invalid argument
 stderr: 2019-04-12 10:39:27.999141 7eff461b6e00 -1  ** ERROR: error creating empty object store in /var/lib/ceph/osd/ceph-0/: (22) Invalid argumen

Ngaphezu koko, ukuba kwisibuko esifanayo (okanye kwenye indawo, oyikhethileyo) udala esinye isahlulelo se-WAL kwaye uyichaze xa udala i-OSD, ngoko yonke into iya kuhamba kakuhle (ngaphandle kokubonakala kwe-WAL eyahlukileyo, onokuthi ungayiboni. bendifuna).

Kodwa, ekubeni yayisekwizicwangciso ezikude zokususa i-WAL iye kwi-NVMe, lo mkhuba awuzange ujike ube yinto engafanelekanga.

root@ceph01-qa:~#ceph-volume lvm create --bluestore --data /dev/sdf --block.wal  /dev/md0p2 --block.db /dev/md1p2

Kwenziwa iimonitha, abaphathi kunye neOSD. Ngoku ndingathanda ukuhlanganisa ngokwahlukileyo, kuba ndiceba ukuba neentlobo ezahlukeneyo zeediski - amachibi akhawulezayo kwi-SSD kunye namachibi amakhulu, kodwa acothayo kwi-pancakes ye-SAS.

Makhe sicinge ukuba abancedisi banamadiski angama-20, ishumi lokuqala luhlobo olunye, okwesibini lunye.
Elokuqala, elihlala lihleli, ikhadi lijongeka ngolu hlobo:

ceph osd umthi

ingcambu@ceph01-q:~# ceph osd umthi
UDIDI LWE-ID Ubunzima UHLOBO IGAMA STATUS REWEIGHT PRI-AFF
-1 14.54799 ingcambu yokusilela
-3 9.09200 umamkeli ceph01-q
0 ssd 1.00000 osd.0 phezulu 1.00000 1.00000
1 ssd 1.00000 osd.1 phezulu 1.00000 1.00000
2 ssd 1.00000 osd.2 phezulu 1.00000 1.00000
3 ssd 1.00000 osd.3 phezulu 1.00000 1.00000
4 hdd 1.00000 osd.4 ukuya 1.00000 1.00000
5 hdd 0.27299 osd.5 ukuya 1.00000 1.00000
6 hdd 0.27299 osd.6 ukuya 1.00000 1.00000
7 hdd 0.27299 osd.7 ukuya 1.00000 1.00000
8 hdd 0.27299 osd.8 ukuya 1.00000 1.00000
9 hdd 0.27299 osd.9 ukuya 1.00000 1.00000
10 hdd 0.27299 osd.10 ukuya 1.00000 1.00000
11 hdd 0.27299 osd.11 ukuya 1.00000 1.00000
12 hdd 0.27299 osd.12 ukuya 1.00000 1.00000
13 hdd 0.27299 osd.13 ukuya 1.00000 1.00000
14 hdd 0.27299 osd.14 ukuya 1.00000 1.00000
15 hdd 0.27299 osd.15 ukuya 1.00000 1.00000
16 hdd 0.27299 osd.16 ukuya 1.00000 1.00000
17 hdd 0.27299 osd.17 ukuya 1.00000 1.00000
18 hdd 0.27299 osd.18 ukuya 1.00000 1.00000
19 hdd 0.27299 osd.19 ukuya 1.00000 1.00000
-5 5.45599 umamkeli ceph02-q
20 ssd 0.27299 osd.20 phezulu 1.00000 1.00000
21 ssd 0.27299 osd.21 phezulu 1.00000 1.00000
22 ssd 0.27299 osd.22 phezulu 1.00000 1.00000
23 ssd 0.27299 osd.23 phezulu 1.00000 1.00000
24 hdd 0.27299 osd.24 ukuya 1.00000 1.00000
25 hdd 0.27299 osd.25 ukuya 1.00000 1.00000
26 hdd 0.27299 osd.26 ukuya 1.00000 1.00000
27 hdd 0.27299 osd.27 ukuya 1.00000 1.00000
28 hdd 0.27299 osd.28 ukuya 1.00000 1.00000
29 hdd 0.27299 osd.29 ukuya 1.00000 1.00000
30 hdd 0.27299 osd.30 ukuya 1.00000 1.00000
31 hdd 0.27299 osd.31 ukuya 1.00000 1.00000
32 hdd 0.27299 osd.32 ukuya 1.00000 1.00000
33 hdd 0.27299 osd.33 ukuya 1.00000 1.00000
34 hdd 0.27299 osd.34 ukuya 1.00000 1.00000
35 hdd 0.27299 osd.35 ukuya 1.00000 1.00000
36 hdd 0.27299 osd.36 ukuya 1.00000 1.00000
37 hdd 0.27299 osd.37 ukuya 1.00000 1.00000
38 hdd 0.27299 osd.38 ukuya 1.00000 1.00000
39 hdd 0.27299 osd.39 ukuya 1.00000 1.00000
-7 6.08690 umamkeli ceph03-q
40 ssd 0.27299 osd.40 phezulu 1.00000 1.00000
41 ssd 0.27299 osd.41 phezulu 1.00000 1.00000
42 ssd 0.27299 osd.42 phezulu 1.00000 1.00000
43 ssd 0.27299 osd.43 phezulu 1.00000 1.00000
44 hdd 0.27299 osd.44 ukuya 1.00000 1.00000
45 hdd 0.27299 osd.45 ukuya 1.00000 1.00000
46 hdd 0.27299 osd.46 ukuya 1.00000 1.00000
47 hdd 0.27299 osd.47 ukuya 1.00000 1.00000
48 hdd 0.27299 osd.48 ukuya 1.00000 1.00000
49 hdd 0.27299 osd.49 ukuya 1.00000 1.00000
50 hdd 0.27299 osd.50 ukuya 1.00000 1.00000
51 hdd 0.27299 osd.51 ukuya 1.00000 1.00000
52 hdd 0.27299 osd.52 ukuya 1.00000 1.00000
53 hdd 0.27299 osd.53 ukuya 1.00000 1.00000
54 hdd 0.27299 osd.54 ukuya 1.00000 1.00000
55 hdd 0.27299 osd.55 ukuya 1.00000 1.00000
56 hdd 0.27299 osd.56 ukuya 1.00000 1.00000
57 hdd 0.27299 osd.57 ukuya 1.00000 1.00000
58 hdd 0.27299 osd.58 ukuya 1.00000 1.00000
59 hdd 0.89999 osd.59 ukuya 1.00000 1.00000

Masenze ezethu iiracks kunye neeseva ezine-blackjack kunye nezinye izinto:

root@ceph01-q:~#ceph osd crush add-bucket rack01 root #создали новый root
root@ceph01-q:~#ceph osd crush add-bucket ceph01-q host #создали новый хост
root@ceph01-q:~#ceph osd crush move ceph01-q root=rack01 #переставили сервер в другую стойку
root@ceph01-q:~#osd crush add 28 1.0 host=ceph02-q # Добавили ОСД в сервер

# Если криво создали то можно удалить
root@ceph01-q:~# ceph osd crush remove osd.4
root@ceph01-q:~# ceph osd crush remove rack01

Iingxaki esidibene nazo ukulwa iqela, xa uzama ukwenza umamkeli omtsha kwaye uyihambise kwindawo ekhoyo yokubeka - umyalelo ceph osd tyumza shukumisa ceph01-host root=rack01 zaqina, kwaye iimonitha zaqala ukuwa nganye nganye. Ukulahlwa komyalelo nge-CTRL+C elula kubuyisele iqela kwilizwe labaphilayo.

Ukhangelo lubonise le ngxaki: https://tracker.ceph.com/issues/23386

Isisombululo siye saba kukulahla i-crushmap kunye nokususa icandelo apho lawula ukuphindaphindwa_umgaqo

root@ceph01-prod:~#ceph osd getcrushmap -o crushmap.row #Дампим карту в сыром виде
root@ceph01-prod:~#crushtool -d crushmap.row -o crushmap.txt #переводим в читаемый
root@ceph01-prod:~#vim  crushmap.txt #редактируем, удаляя rule replicated_ruleset
root@ceph01-prod:~#crushtool -c crushmap.txt  -o new_crushmap.row #компилируем обратно
root@ceph01-prod:~#ceph osd setcrushmap -i  new_crushmap.row #загружаем в кластер

Akhtung: Lo msebenzi unokubangela ulungelelwaniso lweqela lokubeka phakathi kwe-OSD. Ibangele oku kuthi, kodwa kuncinci kakhulu.

Kwaye into engaqhelekanga esiye sadibana nayo kwiqela lovavanyo kukuba emva kokuqalisa kwakhona iseva ye-OSD, balibale ukuba baye bafuduselwa kwiiseva ezintsha kunye neeracks, kwaye babuyela kwingcambu engagqibekanga.
Ngenxa yoko, siqokelele iskimu sokugqibela apho senze khona ingcambu eyahlukileyo ye-ssd drives kunye neyohlukileyo ye-spindle drives, sithathe zonke ii-OSD kwiiracks kwaye sacima ingcambu engagqibekanga. Emva kokuqalisa kwakhona, i-OSD yaqala ukuhlala kwindawo.
Emva kokumba amaxwebhu kamva, sifumene iparameter enoxanduva lokuziphatha. Malunga naye kwinxalenye yesibini

Siwenza njani amaqela ahlukeneyo ngohlobo lwediski.

Ukuqala, senze iingcambu ezimbini - ze-ssd kunye ne-hdd

root@ceph01-q:~#ceph osd crush add-bucket ssd-root root
root@ceph01-q:~#ceph osd crush add-bucket hdd-root root

Kuba iiseva zibekwe ngokwasemzimbeni kwiiracks ezahlukeneyo, ukuze kube lula senze iiracks ezinamaseva kuzo

# Стойки:
root@ceph01-q:~#ceph osd crush add-bucket ssd-rack01 rack
root@ceph01-q:~#ceph osd crush add-bucket ssd-rack02 rack
root@ceph01-q:~#ceph osd crush add-bucket ssd-rack03 rack

root@ceph01-q:~#ceph osd crush add-bucket hdd-rack01 rack
root@ceph01-q:~#ceph osd crush add-bucket hdd-rack01 rack
root@ceph01-q:~#ceph osd crush add-bucket hdd-rack01 rack

# Сервера
root@ceph01-q:~#ceph osd crush add-bucket ssd-ceph01-q host
root@ceph01-q:~#ceph osd crush add-bucket ssd-ceph02-q host
root@ceph01-q:~#ceph osd crush add-bucket ssd-ceph03-q host

root@ceph01-q:~#ceph osd crush add-bucket hdd-ceph01-q host
root@ceph01-q:~#ceph osd crush add-bucket hdd-ceph02-q host
root@ceph01-q:~#ceph osd crush add-bucket hdd-ceph02-q host

kwaye basasaze iidiski ngokweentlobo zazo kwiiseva ezahlukeneyo

root@ceph01-q:~# Диски с 0 по 3 это SSD, находятся в ceph01-q, ставим их в сервер 
root@ceph01-q:~#  ssd-ceph01-q
root@ceph01-q:~#ceph osd crush add 0 1 host=ssd-ceph01-q
root@ceph01-q:~#ceph osd crush add 1 1 host=ssd-ceph01-q
root@ceph01-q:~#ceph osd crush add 2 1 host=ssd-ceph01-q
root@ceph01-q:~#ceph osd crush add 3 1 host=ssd-ceph01-q
root-ceph01-q:~# аналогично с другими серверами

Emva kokuba sasasaza iidiski phakathi kwe-ssd-root kunye neendlela ze-hdd-root, sishiye ingcambu-okungagqibekanga kuyo, ukuze siyicime.

root-ceph01-q:~#ceph osd crush remove default

Emva koko, kufuneka senze imithetho yokusabalalisa esiya kubophezela kumachibi adalwe - kwimigaqo esiya kubonisa ukuba zeziphi iingcambu ezinokubeka idatha yethu ye-pool kunye nenqanaba lokungafani kwe-replica - umzekelo, iikopi kufuneka zibe kumaseva ahlukeneyo, okanye kwiiracks ezahlukeneyo (ungakwiingcambu ezahlukeneyo, ukuba sinosasazo olunjalo)

Ngaphambi kokukhetha uhlobo, kungcono ukufunda amaxwebhu:
http://docs.ceph.com/docs/jewel/rados/operations/crush-map/#crushmaprules

root-ceph01-q:~#ceph osd crush rule create-simple rule-ssd ssd-root host firstn
root-ceph01-q:~#ceph osd crush rule create-simple rule-hdd hdd-root host firstn
root-ceph01-q:~# Мы указали два правила, в которых данные реплицируются 
root-ceph01-q:~# между хостами - то есть реплика должна лежать на другом хосте,
root-ceph01-q:~# даже если они в одной стойке
root-ceph01-q:~# В продакшене, если есть возможность, лучше распределить хосты
root-ceph01-q:~# по стойкам и указать распределять реплики по стойкам:
root-ceph01-q:~# ##ceph osd crush rule create-simple rule-ssd ssd-root rack firstn

Ewe, sakha amachibi apho sifuna ukugcina imifanekiso yedisk ye-virtualization yethu kwixesha elizayo-PROXMOX:

    root-ceph01-q:~# #ceph osd pool create {NAME} {pg_num}  {pgp_num}
    root-ceph01-q:~# ceph osd pool create ssd_pool 1024 1024 
    root-ceph01-q:~# ceph osd pool create hdd_pool 1024 1024

Kwaye siyawaxelela la machibi ukuba yeyiphi imigaqo yokubekwa emayisetyenziswe

 root-ceph01-q:~#ceph osd crush rule ls # смотрим список правил
    root-ceph01-q:~#ceph osd crush rule dump rule-ssd | grep rule_id #выбираем ID нужного
    root-ceph01-q:~#ceph osd pool set ssd_pool crush_rule 2

Ukukhethwa kwenani lamaqela okubekwa kufuneka kujongwe ngombono osele ukho weqela lakho - malunga nokuba zingaphi ii-OSD eziya kubakho, yimalini yedatha (njengepesenti yomthamo opheleleyo) eya kuba equleni, yintoni na. isixa sisonke sedatha.

Lilonke, kuyacetyiswa ukuba ungabi namaqela angaphezu kwama-300 okubekwa kwidiski, kwaye kuya kuba lula ukulungelelanisa kunye namaqela amancinci okubeka - oko kukuthi, ukuba i-pool yakho yonke ithatha i-10 Tb kwaye ine-10 PG kuyo - ngoko ukulinganisa ngokugibisela izitena terabyte (pg) iya kuba yingxaki - ugalele isanti kunye nenani elincinci iinkozo zesanti kwiibhakethi lula kwaye ngakumbi ngokulinganayo).

Kodwa kufuneka sikhumbule ukuba inani elikhulu le-PGs, kokukhona kuchithwa izixhobo ezininzi ekubaleni indawo yazo-inkumbulo kunye ne-CPU ziqala ukusetyenziswa.

Ukuqonda okurhabaxa kunokuba ndinike isixhobo sokubala, enikwe ngabaphuhlisi bemibhalo ye-CEPH.

Uluhlu lwezixhobo:

https://blog.packagecloud.io/eng/2017/02/06/monitoring-tuning-linux-networking-stack-sending-data
http://www.admin-magazine.com/HPC/Articles/Linux-I-O-Schedulers
http://onreader.mdl.ru/MasteringCeph/content/Ch09.html#030202
https://tracker.ceph.com/issues/23386
https://ceph.com/pgcalc/

umthombo: www.habr.com