I-Ceph - kusukela "edolweni" kuya "ukukhiqiza"

Ukukhetha i-CEPH. Ingxenye 1

Sasinama-racks amahlanu, ama-optical switch ayishumi, i-BGP emisiwe, ama-SSD ambalwa kanye nenqwaba yamadiski e-SAS ayo yonke imibala nosayizi, kanye ne-proxmox kanye nesifiso sokubeka yonke idatha emile endaweni yethu yokugcina ye-S3. Hhayi ukuthi konke lokhu kuyadingeka ukuze wenze izinto ezibonakalayo, kepha uma usuqale ukusebenzisa i-opensource, landela umsebenzi wakho wokuzilibazisa kuze kube sekugcineni. Okuwukuphela kwento eyayingiphatha kabi kwakuyi-BGP. Akekho umuntu emhlabeni ongenakuzisiza, ongenandaba nokuziphatha okubi kunomzila wangaphakathi we-BGP. Futhi ngangazi ukuthi maduze nje sizocwila kukho.

I-Ceph - kusukela "edolweni" kuya "ukukhiqiza"

Umsebenzi wawumncane - kwakukhona i-CEPH, kodwa ayizange isebenze kahle kakhulu. Kwakudingekile ukwenza "okuhle".
Iqoqo engilitholile belihlukile, lishunwe ngokushesha futhi alishunwanga. Iqukethe amaqembu amabili ama-node ahlukene, negridi eyodwa evamile esebenza njengokubili iqoqo kanye nenethiwekhi yomphakathi. Ama-node agcwele izinhlobo ezine zamadiski - izinhlobo ezimbili ze-SSD, eziqoqwe emithethweni emibili ehlukene yokubeka, nezinhlobo ezimbili ze-HDD zobukhulu obuhlukene, eziqoqwe eqenjini lesithathu. Inkinga ngosayizi abahlukene yaxazululwa ngezisindo ezihlukene ze-OSD.

Ukusetha ngokwayo kuhlukaniswe izingxenye ezimbili - ukulungiswa kwesistimu yokusebenza и ukulungiswa kwe-CEPH ngokwayo kanye nezilungiselelo zayo.

Ithuthukisa i-OS

Network

Ukubambezeleka okuphezulu kuthinte kokubili ukurekhoda nokulinganisa. Lapho urekhoda - ngenxa yokuthi iklayenti ngeke lithole impendulo mayelana nokurekhoda okuyimpumelelo kuze kube i-replicas yedatha kwamanye amaqembu okubekwa iqinisekisa impumelelo. Njengoba imithetho yokusabalalisa izifaniso kumephu ye-CRUSH yayiyisifaniso esisodwa umsingathi ngamunye, inethiwekhi yayihlala isetshenziswa.

Ngakho-ke, into yokuqala enginqume ukuyenza kwakuwukushintsha kancane inethiwekhi yamanje, ngesikhathi esifanayo ngizama ukungiqinisekisa ukuthi ngithuthele kumanethiwekhi ahlukene.

Okokuqala, ngilungise izilungiselelo zamakhadi enethiwekhi. Ngiqale ngokusetha olayini:

kwenzenjani:

i-ethtool -l en1f1

root@ceph01:~# ethtool -l ens1f1
Channel parameters for ens1f1:
Pre-set maximums:
RX:     0
TX:     0
Other:      1
Combined:   63
Current hardware settings:
RX:     0
TX:     0
Other:      1
Combined:   1
root@ceph01:~# ethtool -g ens1f1
Ring parameters for ens1f1:
Pre-set maximums:
RX:     4096
RX Mini:    0
RX Jumbo:   0
TX:     4096
Current hardware settings:
RX:     256
RX Mini:    0
RX Jumbo:   0
TX:     256
root@ceph01:~# ethtool -l ens1f1
Channel parameters for ens1f1:
Pre-set maximums:
RX:     0
TX:     0
Other:      1
Combined:   63
Current hardware settings:
RX:     0
TX:     0
Other:      1
Combined:   1

Kungabonakala ukuthi amapharamitha amanje akude nama-maximus. Kunyusiwe:

root@ceph01:~#ethtool -G ens1f0 rx 4096
root@ceph01:~#ethtool -G ens1f0 tx 4096
root@ceph01:~#ethtool -L ens1f0 combined 63

Iqondiswa isihloko esihle kakhulu

https://blog.packagecloud.io/eng/2017/02/06/monitoring-tuning-linux-networking-stack-sending-data/

kwandisa ubude bomugqa wokuthumela txqueuelen kusuka ku-1000 kuye ku-10

root@ceph01:~#ip link set ens1f0  txqueuelen 10000

Hhayi-ke, kulandela imibhalo ye-ceph uqobo

https://ceph.com/geen-categorie/ceph-loves-jumbo-frames/

anda MTU kufika ku-9000.

root@ceph01:~#ip link set dev ens1f0  mtu 9000

Kwengezwe ku-/etc/network/interfaces ukuze konke okungenhla kulayishwe ekuqaleni

ikati / etc / network / interface

root@ceph01:~# cat /etc/network/interfaces
auto lo
iface lo inet loopback

auto ens1f0
iface ens1f0 inet manual
post-up /sbin/ethtool -G ens1f0 rx 4096
post-up /sbin/ethtool -G ens1f0 tx 4096
post-up /sbin/ethtool -L ens1f0 combined 63
post-up /sbin/ip link set ens1f0  txqueuelen 10000
mtu 9000

auto ens1f1
iface ens1f1 inet manual
post-up /sbin/ethtool -G ens1f1 rx 4096
post-up /sbin/ethtool -G ens1f1 tx 4096
post-up /sbin/ethtool -L ens1f1 combined 63
post-up /sbin/ip link set ens1f1  txqueuelen 10000
mtu 9000

Ngemuva kwalokho, ngokulandela isihloko esifanayo, ngaqala ukusonta ngokucabangela izibambo ze-4.15 kernel. Uma sicabanga ukuthi ama-node ane-RAM engu-128G, sigcine sinefayela lokucushwa le sysctl

cat /etc/sysctl.d/50-ceph.conf

net.core.rmem_max = 56623104  
#Максимальный размер буфера приема данных для всех соединений  54M
net.core.wmem_max = 56623104
#Максимальный размер буфера передачи данных для всех соединений 54M
net.core.rmem_default = 56623104
#Размер буфера приема данных по умолчанию для всех соединений. 54M
net.core.wmem_default = 56623104
#Размер буфера передачи данных по умолчанию для всех соединений 54M  
# на каждый сокет
net.ipv4.tcp_rmem = 4096 87380 56623104
#Векторная (минимум, по умолчанию, максимум) переменная в файле tcp_rmem
# содержит 3 целых числа, определяющих размер приемного буфера сокетов TCP.
# Минимум: каждый сокет TCP имеет право использовать эту память по 
# факту своего создания. Возможность использования такого буфера 
# гарантируется даже при достижении порога ограничения (moderate memory pressure).
# Размер минимального буфера по умолчанию составляет 8 Кбайт (8192).
#Значение по умолчанию: количество памяти, допустимое для буфера 
# передачи сокета TCP по умолчанию. Это значение применяется взамен
# параметра /proc/sys/net/core/rmem_default, используемого другими протоколами.
# Значение используемого по умолчанию буфера обычно (по умолчанию) 
# составляет 87830 байт. Это определяет размер окна 65535 с 
# заданным по умолчанию значением tcp_adv_win_scale и tcp_app_win = 0, 
# несколько меньший, нежели определяет принятое по умолчанию значение tcp_app_win.
# Максимум: максимальный размер буфера, который может быть автоматически
# выделен для приема сокету TCP. Это значение не отменяет максимума, 
# заданного в файле /proc/sys/net/core/rmem_max. При «статическом»
# выделении памяти с помощью SO_RCVBUF этот параметр не имеет значения.
net.ipv4.tcp_wmem = 4096 65536 56623104
net.core.somaxconn = 5000    
# Максимальное число открытых сокетов, ждущих соединения.
net.ipv4.tcp_timestamps=1
# Разрешает использование временных меток (timestamps), в соответствии с RFC 1323.
net.ipv4.tcp_sack=1
# Разрешить выборочные подтверждения протокола TCP
net.core.netdev_max_backlog=5000 (дефолт 1000)
# максимальное количество пакетов в очереди на обработку, если 
# интерфейс получает пакеты быстрее, чем ядро может их обработать.
net.ipv4.tcp_max_tw_buckets=262144
# Максимальное число сокетов, находящихся в состоянии TIME-WAIT одновременно.
# При превышении этого порога – «лишний» сокет разрушается и пишется
# сообщение в системный журнал.
net.ipv4.tcp_tw_reuse=1
#Разрешаем повторное использование TIME-WAIT сокетов в случаях,
# если протокол считает это безопасным.
net.core.optmem_max=4194304
#Увеличить максимальный общий буфер-космической ALLOCATABLE
#измеряется в единицах страниц (4096 байт)
net.ipv4.tcp_low_latency=1
#Разрешает стеку TCP/IP отдавать предпочтение низкому времени ожидания
# перед более высокой пропускной способностью.
net.ipv4.tcp_adv_win_scale=1
# Эта переменная влияет на вычисление объема памяти в буфере сокета,
# выделяемой под размер TCP-окна и под буфер приложения.
# Если величина tcp_adv_win_scale отрицательная, то для вычисления размера
# используется следующее выражение:
# Bytes- bytes2в степени -tcp_adv_win_scale
# Где bytes – это размер окна в байтах. Если величина tcp_adv_win_scale
# положительная, то для определения размера используется следующее выражение:
# Bytes- bytes2в степени tcp_adv_win_scale
# Переменная принимает целое значение. Значение по-умолчанию – 2, 
# т.е. под буфер приложения отводится ¼ часть объема, определяемого переменной
# tcp_rmem.
net.ipv4.tcp_slow_start_after_idle=0
# механизм перезапуска медленного старта, который сбрасывает значение окна 
# перегрузки, если соединение не использовалось заданный период времени.
# Лучше отключить SSR на сервере, чтобы улучшить производительность 
# долгоживущих соединений.
net.ipv4.tcp_no_metrics_save=1
#Не сохранять результаты измерений TCP соединения в кеше при его закрытии.
net.ipv4.tcp_syncookies=0
#Отключить механизм отправки syncookie
net.ipv4.tcp_ecn=0
#Explicit Congestion Notification (Явное Уведомление о Перегруженности) в 
# TCP-соединениях. Используется для уведомления о возникновении «затора» 
# на маршруте к заданному хосту или сети. Может использоваться для извещения
# хоста-отправителя о необходимости снизить скорость передачи пакетов через
# конкретный маршрутизатор или брандмауэр.
net.ipv4.conf.all.send_redirects=0
# выключает выдачу ICMP Redirect … другим хостам. Эта опция обязательно
# должна быть включена, если хост выступает в роли маршрутизатора любого рода.
# У нас нет маршрутизации.
net.ipv4.ip_forward=0
#Сопсно отключение форвардинга. Мы не шлюз, докер на машинах не поднят,
# нам это не нужно.
net.ipv4.icmp_echo_ignore_broadcasts=1
#Не отвечаем на ICMP ECHO запросы, переданные широковещательными пакетами
net.ipv4.tcp_fin_timeout=10
#определяет время сохранения сокета в состоянии FIN-WAIT-2 после его
# закрытия локальной стороной. Дефолт 60
net.core.netdev_budget=600 # (дефолт 300)
# Если выполнение программных прерываний не выполняются достаточно долго,
# то темп роста входящих данных может превысить возможность ядра 
# опустошить буфер. В результате буферы NIC переполнятся, и трафик будет потерян.
# Иногда, необходимо увеличить длительность работы SoftIRQs
# (программных прерываний) с CPU. За это отвечает netdev_budget. 
# Значение по умолчанию 300. Параметр заставит процесс SoftIRQ обработать
# 300 пакетов от NIC перед тем как отпустить CPU
net.ipv4.tcp_fastopen=3
# TFO TCP Fast Open
# если и клиент и сервер имеют поддержку TFO, о которой сообщают за счет
# специального флага в TCP пакете. В нашем случае является плацебо, просто
# выглядит красиво)

Сinethiwekhi ekhanyayo yabelwa ezindaweni ezihlukene zenethiwekhi ye-10Gbps ibe inethiwekhi eyisicaba ehlukile. Umshini ngamunye wawufakwe amakhadi enethiwekhi anezimbobo ezimbili i-mellanox 10/25 Gbps, ixhunywe kumaswishi amabili ahlukene we-10Gbps. Ukuhlanganisa kwenziwa kusetshenziswa i-OSPF, njengoba ukuhlangana ne-lacp ngesizathu esithile kubonise ukuphuma okuphelele kokufika ku-16 Gbps, kuyilapho i-ospf isebenzise ngempumelelo womabili amashumi emshinini ngamunye. Izinhlelo zesikhathi esizayo bekuwukusebenzisa i-ROCE kulawa ma-melanox ukunciphisa ukubambezeleka. Uyisetha kanjani le ngxenye yenethiwekhi:

  1. Njengoba imishini ngokwayo inamakheli e-IP angaphandle ku-BGP, sidinga isofthiwe - (ngokunembile, ngesikhathi sokubhala lesi sihloko frr=6.0-1 ) wayesevele emile.
  2. Sekukonke, imishini ibinokuxhumana kwenethiwekhi okubili, ngayinye inokuxhumana okubili - isamba samachweba ama-4. Ikhadi elilodwa lenethiwekhi lalibheka imboni enamachweba amabili futhi i-BGP yahlelwa kuyo, elesibili libheka amaswishi amabili ahlukene anamachweba amabili kanye ne-OSPF ebekwe kuyo.

Imininingwane eyengeziwe ekusetheni i-OSPF: Umsebenzi oyinhloko ukuhlanganisa izixhumanisi ezimbili futhi ube nokubekezelela amaphutha.
ukuxhumana kwenethiwekhi okubili kucushwe kube amanethiwekhi amabili alula ayisicaba - 10.10.10.0/24 kanye no-10.10.20.0/24

1: ens1f0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 9000 qdisc mq state UP group default qlen 1000
inet 10.10.10.2/24 brd 10.10.10.255 scope global ens1f0
2: ens1f1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 9000 qdisc mq state UP group default qlen 1000
inet 10.10.20.2/24 brd 10.10.20.255 scope global ens1f1

ezibonana ngazo izimoto.

IDISKI

Isinyathelo esilandelayo kwakuwukuthuthukisa amadiski. Nge-SSD ngishintshe isihleli saba noop, ye-HDD - Umkhawulo wokugcina. Ukukubeka ngembaba, i-NOOP isebenza ngomgomo othi “kuqala ukungena, kuphume kuqala,” ngesiNgisi kuzwakale njengokuthi “FIFO (First In, First Out).” Izicelo zifakwa kulayini njengoba zifika. I-DEADLINE igxile ekufundeni, futhi inqubo ekulayini ithola ukufinyelela okukhethekile kudiski ngesikhathi sokusebenza. Lokhu kulungele uhlelo lwethu - emva kwakho konke, inqubo eyodwa kuphela esebenza ngediski ngayinye - i-OSD daemon.
(Labo abafuna ukucwila kumhleli we-I/O bangafunda ngakho lapha:
http://www.admin-magazine.com/HPC/Articles/Linux-I-O-Schedulers

Labo abakhetha ukufunda ngesiRashiya: https://www.opennet.ru/base/sys/linux_shedulers.txt.html)

Ezincomweni zokushuna i-Linux, kuyanconywa futhi ukuthi ukhuphule i-nr_request

nr_izicelo
Inani le-nr_requests linquma inani lezicelo ze-I/O ezifakwa kubhafa ngaphambi kokuba umhleli we-I/O athumele / athole idatha kudivayisi ye-block, uma usebenzisa ikhadi le-RAID / Vimba idivayisi engakwazi ukuphatha umugqa omkhulu kunalokho i-I Isihleli /O sisethwe ukuze, ukuphakamisa inani le-nr_requests kungase kusize ukuthuthukisa kuyo yonke indawo futhi kunciphise umthwalo weseva lapho amanani amakhulu we-I/O evela kuseva. Uma usebenzisa Umnqamulajuqu noma i-CFQ njengomhleli, kuphakanyiswa ukuthi usethe inani le-nr_request libe izikhathi ezingu-2 inani lokujula komugqa.

KODWA! Izakhamizi ngokwazo, abathuthukisi be-CEPH, basiqinisekisa ukuthi uhlelo lwazo lwezinto eziza kuqala lusebenza kangcono

I-Ceph - kusukela "edolweni" kuya "ukukhiqiza"

I-WBTthrottle kanye/noma i-nr_requests

I-WBTthrottle kanye/noma i-nr_requests
Isitoreji sefayela sisebenzisa i-I/O evikelwe ekubhaleni; lokhu kuletha izinzuzo eziningi uma irekhodi lokugcina ifayela likumidiya esheshayo. Izicelo zeklayenti ziyaziswa ngokushesha ngemva kokubhalwa kwedatha kulogi, bese zidluliselwa kudiski yedatha ngokwayo ngokuhamba kwesikhathi kusetshenziswa ukusebenza okujwayelekile kwe-Linux. Lokhu kwenza kube nokwenzeka ukuthi ama-OSD e-spindle ahlinzeke nge-latency yokubhala efana nama-SSD uma ubhala ngokuqhuma okuncane. Lokhu kubhala okubambezelekile emuva futhi kuvumela i-kernel ngokwayo ukuthi ihlele kabusha izicelo ze-disk I/O, ngethemba lokuzihlanganisa ndawonye noma ukuvumela amakhanda ediski akhona ukuthi akhethe enye indlela elunge ngaphezulu kwamapuleti awo. Umphumela uwukuthi ungakwazi ukushutheka kancane i-I/O kudiski ngayinye kunalokho obekungenzeka nge-I/O eqondile noma ehambisanayo.

Kodwa-ke, inkinga ethile iphakama uma ivolumu yamarekhodi angenayo kuqoqo le-Ceph elinikeziwe lidlula wonke amakhono amadiski angaphansi. Kulesi simo, inani eliphelele lemisebenzi ye-I/O elindile ukubhalwa kudiski lingakhula ngokungalawuleki futhi liphumele emigqeni ye-I/O egcwalisa yonke idiski nolayini be-Ceph. Izicelo zokufunda zithinteka kakhulu ngenxa yokuthi zibambeka phakathi kwezicelo zokubhala, okungathatha imizuzwana embalwa ukudlulela kudiski eyinhloko.

Ukuze unqobe le nkinga, i-Ceph inomshini wokubhala emuva owakhelwe endaweni yokugcina ifayela ebizwa ngokuthi i-WBThrottle. Idizayinelwe ukukhawulela inani eliphelele le-I/O yokuvilapha engakwazi ukuklelisa futhi iqale inqubo yayo yokuguquguquka ngaphambi kwalokho obekungenzeka ngokwemvelo ngenxa yokunikwa amandla yi-kernel ngokwayo. Ngeshwa, ukuhlola kubonisa ukuthi amanani azenzakalelayo asengase anganciphisi ukuziphatha okukhona abe sezingeni elinganciphisa lo mthelela ekubambezelekeni kokufunda. Ukulungiswa kungashintsha lokhu kuziphatha futhi kunciphise bonke ubude bomugqa wokubhala futhi kwenze lokhu kuthinteke kungabi nzima kakhulu. Kukhona ukuhwebelana, nokho: ngokunciphisa inani eliphakeme lilonke lokufakiwe okuvunyelwe ukufakwa kulayini, unganciphisa ikhono le-kernel ngokwalo ukukhulisa ukusebenza kahle kwayo eku-odeni izicelo ezingenayo. Kuyafaneleka ukuthi ucabange kancane ngalokho okudingayo okwengeziwe ngecala lakho elithile lokusebenzisa, umthwalo wokusebenza kanye nokulungisa ukuze uvumelane nawo.

Ukuze ulawule ukujula komugqa onjalo wokubhala-backlog, ungakwazi ukunciphisa inani eliphakeme lilonke lemisebenzi esele ye-I/O usebenzisa izilungiselelo ze-WBThrottle, noma ungakwazi ukunciphisa inani eliphezulu lemisebenzi esele ezingeni lebhulokhi le-kernel yakho ngokwayo. Kokubili kungalawula ngempumelelo ukuziphatha okufanayo, futhi okuncamelayo kuzoba yisisekelo sokusebenzisa lesi silungiselelo.
Kufanele futhi kuqashelwe ukuthi uhlelo lokusebenza olubalulekile lwe-Ceph lusebenza kahle kakhulu emibuzweni emifushane ezingeni lediski. Ngokunciphisa ulayini ophelele kudiski enikeziwe, indawo eyinhloko yolayini ithuthela e-Ceph, lapho inokulawula okwengeziwe kokuthi umsebenzi we-I/O obaluleke kangakanani. Cabangela isibonelo esilandelayo:

echo 8 > /sys/block/sda/queue/nr_requests

http://onreader.mdl.ru/MasteringCeph/content/Ch09.html#030202

I-COMMON

Nokunye okungeziwe kwe-kernel tweaks ukwenza imoto yakho ithambe futhi ibe silky bese ucindezela ukusebenza kancane okwengeziwe ku-hardware.

cat /etc/sysctl.d/60-ceph2.conf

 kernel.pid_max = 4194303
#Дисков в каждой машине по 25, потому рассчитывали что процессов будет много
kernel.threads-max=2097152
# Тредов, естессно, тоже.
vm.max_map_count=524288
# Увеличили количество областей карты памяти процесса. 
# Как следует из документации по ядерным переменным 
# Области карты памяти используется как побочный эффект вызова
# malloc, напрямую с помощью mmap, mprotect и madvise, а также при загрузке
# общих библиотек.
fs.aio-max-nr=50000000
# Подтюним параметры input-output
# Ядро Linux предоставляет функцию асинхронного неблокирующего ввода-вывода (AIO),
# которая позволяет процессу инициировать несколько операций ввода-вывода
# одновременно, не дожидаясь завершения какой-либо из них. 
# Это помогает повысить производительность приложений, 
# которые могут перекрывать обработку и ввод-вывод.
# Параметр aio-max-nr определяет максимальное количество допустимых 
# одновременных запросов.
vm.min_free_kbytes=1048576
# минимальный размер свободной памяти который необходимо поддерживать.
# Выставлен 1Gb, чего вполне достаточно для работы операционной системы, 
# и позволяет избегать OOM Killer для процессов OSD. Хотя памяти и так
# как у дурака фантиков, но запас карман не тянет
vm.swappiness=10
# Говорим использовать своп если осталось свободным 10% памяти.
# На машинах 128G оперативы, и 10% это 12 Гигов. Более чем достаточно для работы.
# Штатный параметр в 60% заставлял тормозить систему, залезая в своп,
# когда есть еще куча свободной памяти
vm.vfs_cache_pressure=1000
# Увеличиваем со штатных 100. Заставляем ядро активнее выгружать
# неиспользуемые страницы памяти из кеша.
vm.zone_reclaim_mode=0
# Позволяет  устанавливать более или менее агрессивные подходы к
# восстановлению памяти, когда в зоне заканчивается память. 
# Если он установлен на ноль, то не происходит восстановление зоны.
# Для файловых серверов или рабочих нагрузок
# выгодно, если их данные кэшированы, zone_reclaim_mode
# оставить отключенным, поскольку эффект кэширования, 
# вероятно, будет более важным, чем местонахождение данных.
vm.dirty_ratio=20
# Процент оперативной памяти, который можно выделить под "грязные" страницы
# Вычисляли из примерного расчета: 
# В система 128 гигов памяти.
# Примерно по 20 дисков SSD, у которых в настройках CEPH указано 
# выделять под кэширование по 3G оперативы.
# Примерно по 40 дисков HDD, для которых этот параметр равен 1G
# 20% от 128 это 25.6 гигов. Итого, в случае максимальной утилизации памяти,
# для системы останется 2.4G памяти. Чего ей должно хватить чтоб выжить и дождаться
# стука копыт кавалерии - то есть пришествия DevOps который все починит.
vm.dirty_background_ratio=3
# процент системной памяти, который можно заполнить dirty pages до того,
# как фоновые процессы pdflush/flush/kdmflush запишут их на диск
fs.file-max=524288
# Ну и открытых файлов у нас,вероятно, будет сильно больше, чем указано по дефолту. 

Ukucwiliswa ku-CEPH

Izilungiselelo engingathanda ukuhlala kuzo ngokuningiliziwe:

ikati /etc/ceph/ceph.conf

osd:
journal_aio: true               # Три параметра, включающие 
journal_block_align: true       # прямой i/o
journal_dio: true               # на журнал
journal_max_write_bytes: 1073714824 # Немного растянем максимальный размер
# разово записываемой операции в журнал
journal_max_write_entries: 10000    # Ну и количество одновременных записей
journal_queue_max_bytes: 10485760000 
journal_queue_max_ops: 50000
rocksdb_separate_wal_dir: true      # Решили делать отдельный wal                                                                            
# Даже попытались выбить под это дело                                                                                                                                                                                     
# NVMe
bluestore_block_db_create: true     # Ну и под журнал отдельное устройство
bluestore_block_db_size: '5368709120 #5G'
bluestore_block_wal_create: true
bluestore_block_wal_size: '1073741824   #1G' 
bluestore_cache_size_hdd: '3221225472   # 3G' 
# большой объем оперативы позволяет 
# хранить достаточно большие объемы
bluestore_cache_size_ssd: '9663676416   # 9G' 
keyring: /var/lib/ceph/osd/ceph-$id/keyring
osd_client_message_size_cap: '1073741824 #1G'
osd_disk_thread_ioprio_class: idle
osd_disk_thread_ioprio_priority: 7
osd_disk_threads: 2 # количество тредов у демона на один диск
osd_failsafe_full_ratio: 0.95
osd_heartbeat_grace: 5
osd_heartbeat_interval: 3
osd_map_dedup: true
osd_max_backfills: 2 # количество одновременных операций заполнения на один ОСД.
osd_max_write_size: 256
osd_mon_heartbeat_interval: 5
osd_op_threads: 16
osd_op_num_threads_per_shard: 1
osd_op_num_threads_per_shard_hdd: 2
osd_op_num_threads_per_shard_ssd: 2
osd_pool_default_min_size: 1     # Особенности жадности. Очень быстро стало
osd_pool_default_size: 2         # нехватать места, потому как временное                                                                                                                                                      
# решение приняли уменьшение количество 
# реплик данных
osd_recovery_delay_start: 10.000000
osd_recovery_max_active: 2
osd_recovery_max_chunk: 1048576
osd_recovery_max_single_start: 3
osd_recovery_op_priority: 1
osd_recovery_priority: 1            # параметр регулируем по необходимости на ходу
osd_recovery_sleep: 2
osd_scrub_chunk_max: 4

Amanye amapharamitha ahlolelwe i-QA kunguqulo 12.2.12 awatholakali ku-ceph version 12.2.2, isibonelo osd_recovery_threads. Ngakho-ke, izinhlelo zazihlanganisa nokubuyekezwa kokukhiqizwa ku-12.2.12. Ukuzijwayeza kubonise ukuhambisana phakathi kwezinguqulo 12.2.2 kanye no-12.2.12 kuqoqo elilodwa, elivumela ukuthuthukiswa kokubuyekezwa.

Iqoqo lokuhlola

Ngokwemvelo, ukuze kuhlolwe kwakudingeka kube nenguqulo efanayo njengasempini, kodwa ngesikhathi ngiqala ukusebenza neqoqo, kwakutholakala entsha kuphela endaweni yokugcina. Uma usubhekile, ongakubona enguqulweni encane akukukhulu kakhulu (1393 imigqa ku-configs ngokumelene 1436 enguqulweni entsha), sinqume ukuqala ukuhlola entsha (ukubuyekeza noma kunjalo, kungani uhamba nodoti omdala)

Into kuphela esizame ukuyishiya ngemuva kwenguqulo endala iphakheji ceph-deploy njengoba ezinye zezinsiza (kanye nezinye zezisebenzi) zenziwe zafanelana ne-syntax yayo. Inguqulo entsha yayihluke kakhulu, kodwa ayizange ithinte ukusebenza kweqoqo ngokwalo, futhi ishiywe enguqulweni 1.5.39

Njengoba umyalo we-ceph-disk usho ngokucacile ukuthi wehlisiwe futhi usebenzise umyalo we-ceph-volume, bathandekayo, siqale ukudala ama-OSD ngalo myalo, ngaphandle kokuchitha isikhathi kulawo aphelelwe yisikhathi.

Uhlelo bekuwukwakha isibuko samadrayivu amabili e-SSD lapho sizobeka khona izingodo ze-OSD, zona, ezitholakala kuma-spindle SAS. Ngale ndlela singakwazi ukuzivikela ezinkingeni ngedatha uma idiski enelogi iwe.

Saqala ukwakha iqoqo ngokuvumelana nemibhalo

ikati /etc/ceph/ceph.conf

root@ceph01-qa:~# cat /etc/ceph/ceph.conf # положили заранее подготовленный конфиг
[client]
rbd_cache = true
rbd_cache_max_dirty = 50331648
rbd_cache_max_dirty_age = 2
rbd_cache_size = 67108864
rbd_cache_target_dirty = 33554432
rbd_cache_writethrough_until_flush = true
rbd_concurrent_management_ops = 10
rbd_default_format = 2
[global]
auth_client_required = cephx
auth_cluster_required = cephx
auth_service_required = cephx
cluster network = 10.10.10.0/24
debug_asok = 0/0
debug_auth = 0/0
debug_buffer = 0/0
debug_client = 0/0
debug_context = 0/0
debug_crush = 0/0
debug_filer = 0/0
debug_filestore = 0/0
debug_finisher = 0/0
debug_heartbeatmap = 0/0
debug_journal = 0/0
debug_journaler = 0/0
debug_lockdep = 0/0
debug_mon = 0/0
debug_monc = 0/0
debug_ms = 0/0
debug_objclass = 0/0
debug_objectcatcher = 0/0
debug_objecter = 0/0
debug_optracker = 0/0
debug_osd = 0/0
debug_paxos = 0/0
debug_perfcounter = 0/0
debug_rados = 0/0
debug_rbd = 0/0
debug_rgw = 0/0
debug_throttle = 0/0
debug_timer = 0/0
debug_tp = 0/0
fsid = d0000000d-4000-4b00-b00b-0123qwe123qwf9
mon_host = ceph01-q, ceph02-q, ceph03-q
mon_initial_members = ceph01-q, ceph02-q, ceph03-q
public network = 8.8.8.8/28 # адрес изменен, естественно ))
rgw_dns_name = s3-qa.mycompany.ru # и этот адрес измен
rgw_host = s3-qa.mycompany.ru # и этот тоже
[mon]
mon allow pool delete = true
mon_max_pg_per_osd = 300 # больше трехсот плейсмент групп
# на диск не решились
# хотя параметр, естественно, зависит от количества пулов,
# их размеров и количества OSD. Иметь мало но здоровых PG
# тоже не лучший выбор - страдает точность балансировки
mon_osd_backfillfull_ratio = 0.9
mon_osd_down_out_interval = 5
mon_osd_full_ratio = 0.95 # пока для SSD дисков местом для их
# журнала является тот-же девайс что и для ОСД
# решили что 5% от диска (который сам размером 1.2Tb)
#  должно вполне хватить, и коррелирует с параметром
# bluestore_block_db_size плюс вариативность на большие 
# плейсмент группы
mon_osd_nearfull_ratio = 0.9
mon_pg_warn_max_per_osd = 520
[osd]
bluestore_block_db_create = true
bluestore_block_db_size = 5368709120 #5G
bluestore_block_wal_create = true
bluestore_block_wal_size = 1073741824 #1G
bluestore_cache_size_hdd = 3221225472 # 3G
bluestore_cache_size_ssd = 9663676416 # 9G
journal_aio = true
journal_block_align = true
journal_dio = true
journal_max_write_bytes = 1073714824
journal_max_write_entries = 10000
journal_queue_max_bytes = 10485760000
journal_queue_max_ops = 50000
keyring = /var/lib/ceph/osd/ceph-$id/keyring
osd_client_message_size_cap = 1073741824 #1G
osd_disk_thread_ioprio_class = idle
osd_disk_thread_ioprio_priority = 7
osd_disk_threads = 2
osd_failsafe_full_ratio = 0.95
osd_heartbeat_grace = 5
osd_heartbeat_interval = 3
osd_map_dedup = true
osd_max_backfills = 4
osd_max_write_size = 256
osd_mon_heartbeat_interval = 5
osd_op_num_threads_per_shard = 1
osd_op_num_threads_per_shard_hdd = 2
osd_op_num_threads_per_shard_ssd = 2
osd_op_threads = 16
osd_pool_default_min_size = 1
osd_pool_default_size = 2
osd_recovery_delay_start = 10.0
osd_recovery_max_active = 1
osd_recovery_max_chunk = 1048576
osd_recovery_max_single_start = 3
osd_recovery_op_priority = 1
osd_recovery_priority = 1
osd_recovery_sleep = 2
osd_scrub_chunk_max = 4
osd_scrub_chunk_min = 2
osd_scrub_sleep = 0.1
rocksdb_separate_wal_dir = true

# создаем мониторы
root@ceph01-qa:~#ceph-deploy mon create ceph01-q
# генерируем ключи для аутентификации нод в кластере
root@ceph01-qa:~#ceph-deploy gatherkeys ceph01-q
# Это если поштучно. Если у нас несколько машин доступны - те, которые описаны в конфиге в секции 
# mon_initial_members = ceph01-q, ceph02-q, ceph03-q
# можно запустить эти две команды в виде одной
root@ceph01-qa:~#ceph-deploy mon create-initial
# Положим ключи в указанные в конфиге места
root@ceph01-qa:~#cat ceph.bootstrap-osd.keyring > /var/lib/ceph/bootstrap-osd/ceph.keyring 
root@ceph01-qa:~#cat ceph.bootstrap-mgr.keyring > /var/lib/ceph/bootstrap-mgr/ceph.keyring 
root@ceph01-qa:~#cat ceph.bootstrap-rgw.keyring > /var/lib/ceph/bootstrap-rgw/ceph.keyring
# создадим ключ для управления кластером
root@ceph01-qa:~#ceph-deploy admin ceph01-q
# и менеджер, плагинами управлять
root@ceph01-qa:~#ceph-deploy mgr create ceph01-q

Into yokuqala engifike ngayo lapho ngisebenza nale nguqulo ye-ceph-deploy enenguqulo ye-cluster engu-12.2.12 kwaba iphutha ngenkathi uzama ukudala i-OSD nge-db ekuhlaselweni kwesofthiwe -

root@ceph01-qa:~#ceph-volume lvm create --bluestore --data /dev/sde --block.db /dev/md0
blkid could not detect a PARTUUID for device: /dev/md1

Ngempela, i-blkid ayibonakali i-PARTUUID, ngakho-ke bekufanele ngenze ukwahlukanisa ngesandla:

root@ceph01-qa:~#parted /dev/md0 mklabel GPT 
# разделов будет много, 
# без GPT их создать не получится
# размер раздела мы указали в конфиге выше = bluestore_block_db_size: '5368709120 #5G'
# Дисков у меня 20 под OSD, руками создавать разделы лень
# потому сделал цикл
root@ceph01-qa:~#for i in {1..20}; do echo -e "nnnn+5Gnw" | fdisk /dev/md0; done

Konke kubonakala kulungile, sizama ukudala i-OSD futhi futhi sithole iphutha elilandelayo (okuyinto, ngendlela, engazange yenziwe kabusha empini)

lapho udala i-OSD yohlobo lwe-bluestore ngaphandle kokucacisa indlela eya ku-WAL, kodwa ucacise i-db

root@ceph01-qa:~#ceph-volume lvm create --bluestore --data /dev/sde --block.db /dev/md0
stderr: 2019-04-12 10:39:27.211242 7eff461b6e00 -1 bluestore(/var/lib/ceph/osd/ceph-0/) _read_fsid unparsable uuid
stderr: 2019-04-12 10:39:27.213185 7eff461b6e00 -1 bdev(0x55824c273680 /var/lib/ceph/osd/ceph-0//block.wal) open open got: (22) Invalid argument
stderr: 2019-04-12 10:39:27.213201 7eff461b6e00 -1 bluestore(/var/lib/ceph/osd/ceph-0/) _open_db add block device(/var/lib/ceph/osd/ceph-0//block.wal) returned: (22) Invalid argument
stderr: 2019-04-12 10:39:27.999039 7eff461b6e00 -1 bluestore(/var/lib/ceph/osd/ceph-0/) mkfs failed, (22) Invalid argument
stderr: 2019-04-12 10:39:27.999057 7eff461b6e00 -1 OSD::mkfs: ObjectStore::mkfs failed with error (22) Invalid argument
stderr: 2019-04-12 10:39:27.999141 7eff461b6e00 -1  ** ERROR: error creating empty object store in /var/lib/ceph/osd/ceph-0/: (22) Invalid argumen

Ngaphezu kwalokho, uma esibukweni esifanayo (noma kwenye indawo, ozikhethele) udala enye ukwahlukanisa kwe-WAL futhi ucacise lapho udala i-OSD, khona-ke konke kuzohamba kahle (ngaphandle kokuvela kwe-WAL ehlukile, ongase ungayiboni. bengifuna).

Kodwa, njengoba kwakusesezinhlelweni ezikude zokuthutha i-WAL iye ku-NVMe, lo mkhuba awuzange ubonakale ungaphezu kwamandla.

root@ceph01-qa:~#ceph-volume lvm create --bluestore --data /dev/sdf --block.wal  /dev/md0p2 --block.db /dev/md1p2

Kwakhiwe amamonitha, abaphathi kanye ne-OSD. Manje ngingathanda ukuwahlanganisa ngokuhlukile, ngoba ngihlela ukuba nezinhlobo ezahlukene zamadiski - amachibi asheshayo ku-SSD namachibi amakhulu, kodwa ahamba kancane kuma-pancake e-SAS.

Ake sicabange ukuthi amaseva anamadiski angama-20, eziyishumi zokuqala ziwuhlobo olulodwa, owesibili ngolunye.
Elokuqala, elizenzakalelayo, ikhadi libukeka kanje:

ceph osd isihlahla

impande@ceph01-q:~# ceph osd isihlahla
UHLOBO LWESISINZO LWESIKSI KA-ID IGAMA ISIMO SESIKHATHI SESILINGANE PRI-AFF
-1 14.54799 okuzenzakalelayo kwezimpande
-3 9.09200 umphathi ceph01-q
0 ssd 1.00000 osd.0 phezulu 1.00000 1.00000
1 ssd 1.00000 osd.1 phezulu 1.00000 1.00000
2 ssd 1.00000 osd.2 phezulu 1.00000 1.00000
3 ssd 1.00000 osd.3 phezulu 1.00000 1.00000
4 HDD 1.00000 osd.4 phezulu 1.00000 1.00000
5 HDD 0.27299 osd.5 phezulu 1.00000 1.00000
6 HDD 0.27299 osd.6 phezulu 1.00000 1.00000
7 HDD 0.27299 osd.7 phezulu 1.00000 1.00000
8 HDD 0.27299 osd.8 phezulu 1.00000 1.00000
9 HDD 0.27299 osd.9 phezulu 1.00000 1.00000
10 HDD 0.27299 osd.10 phezulu 1.00000 1.00000
11 HDD 0.27299 osd.11 phezulu 1.00000 1.00000
12 HDD 0.27299 osd.12 phezulu 1.00000 1.00000
13 HDD 0.27299 osd.13 phezulu 1.00000 1.00000
14 HDD 0.27299 osd.14 phezulu 1.00000 1.00000
15 HDD 0.27299 osd.15 phezulu 1.00000 1.00000
16 HDD 0.27299 osd.16 phezulu 1.00000 1.00000
17 HDD 0.27299 osd.17 phezulu 1.00000 1.00000
18 HDD 0.27299 osd.18 phezulu 1.00000 1.00000
19 HDD 0.27299 osd.19 phezulu 1.00000 1.00000
-5 5.45599 umphathi ceph02-q
20 ssd 0.27299 osd.20 phezulu 1.00000 1.00000
21 ssd 0.27299 osd.21 phezulu 1.00000 1.00000
22 ssd 0.27299 osd.22 phezulu 1.00000 1.00000
23 ssd 0.27299 osd.23 phezulu 1.00000 1.00000
24 HDD 0.27299 osd.24 phezulu 1.00000 1.00000
25 HDD 0.27299 osd.25 phezulu 1.00000 1.00000
26 HDD 0.27299 osd.26 phezulu 1.00000 1.00000
27 HDD 0.27299 osd.27 phezulu 1.00000 1.00000
28 HDD 0.27299 osd.28 phezulu 1.00000 1.00000
29 HDD 0.27299 osd.29 phezulu 1.00000 1.00000
30 HDD 0.27299 osd.30 phezulu 1.00000 1.00000
31 HDD 0.27299 osd.31 phezulu 1.00000 1.00000
32 HDD 0.27299 osd.32 phezulu 1.00000 1.00000
33 HDD 0.27299 osd.33 phezulu 1.00000 1.00000
34 HDD 0.27299 osd.34 phezulu 1.00000 1.00000
35 HDD 0.27299 osd.35 phezulu 1.00000 1.00000
36 HDD 0.27299 osd.36 phezulu 1.00000 1.00000
37 HDD 0.27299 osd.37 phezulu 1.00000 1.00000
38 HDD 0.27299 osd.38 phezulu 1.00000 1.00000
39 HDD 0.27299 osd.39 phezulu 1.00000 1.00000
-7 6.08690 umphathi ceph03-q
40 ssd 0.27299 osd.40 phezulu 1.00000 1.00000
41 ssd 0.27299 osd.41 phezulu 1.00000 1.00000
42 ssd 0.27299 osd.42 phezulu 1.00000 1.00000
43 ssd 0.27299 osd.43 phezulu 1.00000 1.00000
44 HDD 0.27299 osd.44 phezulu 1.00000 1.00000
45 HDD 0.27299 osd.45 phezulu 1.00000 1.00000
46 HDD 0.27299 osd.46 phezulu 1.00000 1.00000
47 HDD 0.27299 osd.47 phezulu 1.00000 1.00000
48 HDD 0.27299 osd.48 phezulu 1.00000 1.00000
49 HDD 0.27299 osd.49 phezulu 1.00000 1.00000
50 HDD 0.27299 osd.50 phezulu 1.00000 1.00000
51 HDD 0.27299 osd.51 phezulu 1.00000 1.00000
52 HDD 0.27299 osd.52 phezulu 1.00000 1.00000
53 HDD 0.27299 osd.53 phezulu 1.00000 1.00000
54 HDD 0.27299 osd.54 phezulu 1.00000 1.00000
55 HDD 0.27299 osd.55 phezulu 1.00000 1.00000
56 HDD 0.27299 osd.56 phezulu 1.00000 1.00000
57 HDD 0.27299 osd.57 phezulu 1.00000 1.00000
58 HDD 0.27299 osd.58 phezulu 1.00000 1.00000
59 HDD 0.89999 osd.59 phezulu 1.00000 1.00000

Ake sizakhele ama-racks namaseva ethu nge-blackjack nezinye izinto:

root@ceph01-q:~#ceph osd crush add-bucket rack01 root #создали новый root
root@ceph01-q:~#ceph osd crush add-bucket ceph01-q host #создали новый хост
root@ceph01-q:~#ceph osd crush move ceph01-q root=rack01 #переставили сервер в другую стойку
root@ceph01-q:~#osd crush add 28 1.0 host=ceph02-q # Добавили ОСД в сервер
# Если криво создали то можно удалить
root@ceph01-q:~# ceph osd crush remove osd.4
root@ceph01-q:~# ceph osd crush remove rack01

Izinkinga esihlangabezane nazo ukulwa iqoqo, lapho uzama ukwakha umsingathi omusha bese uyihambisa ku-rack ekhona - umyalo ceph osd crush move ceph01-host root=rack01 ama-monitor aqala ukuwa ngamunye ngamunye. Ukuhoxisa umyalo nge-CTRL+C elula kubuyisele iqoqo emhlabeni wabaphilayo.

Ukusesha kubonise le nkinga: https://tracker.ceph.com/issues/23386

Isixazululo kube ukulahla i-crushmap nokususa isigaba lapho rule replicated_ruleset

root@ceph01-prod:~#ceph osd getcrushmap -o crushmap.row #Дампим карту в сыром виде
root@ceph01-prod:~#crushtool -d crushmap.row -o crushmap.txt #переводим в читаемый
root@ceph01-prod:~#vim  crushmap.txt #редактируем, удаляя rule replicated_ruleset
root@ceph01-prod:~#crushtool -c crushmap.txt  -o new_crushmap.row #компилируем обратно
root@ceph01-prod:~#ceph osd setcrushmap -i  new_crushmap.row #загружаем в кластер

Akhtung: Lokhu kusebenza kungase kubangele ukulingana kweqembu lokubeka phakathi kwama-OSD. Kusibangele lokhu, kodwa kuncane kakhulu.

Futhi into exakayo esihlangabezane nayo kuqoqo lokuhlola ukuthi ngemva kokuqalisa kabusha iseva ye-OSD, bakhohlwe ukuthi bahanjiswe kumaseva amasha nama-racks, futhi babuyela kokuzenzakalelayo kwempande.
Ngenxa yalokho, ngemva kokuhlanganisa uhlelo lokugcina lapho sidale khona impande ehlukile yamadrayivu e-ssd kanye nesehlukile samadrayivu e-spindle, sithathe wonke ama-OSD sawenza ama-rack futhi samane sasusa impande ezenzakalelayo. Ngemva kokuqalisa kabusha, i-OSD yaqala ukuhlala endaweni.
Ngemva kokumba amadokhumenti kamuva, sithole ipharamitha enesibopho salokhu kuziphatha. Mayelana naye engxenyeni yesibili

Senza kanjani amaqembu ahlukene ngohlobo lwediski.

Okokuqala, sidale izimpande ezimbili - ze-ssd kanye ne-hdd

root@ceph01-q:~#ceph osd crush add-bucket ssd-root root
root@ceph01-q:~#ceph osd crush add-bucket hdd-root root

Njengoba amaseva atholakala ngokoqobo kuma-rack ahlukene, ukuze kube lula sidale ama-rack anamaseva kuwo

# Стойки:
root@ceph01-q:~#ceph osd crush add-bucket ssd-rack01 rack
root@ceph01-q:~#ceph osd crush add-bucket ssd-rack02 rack
root@ceph01-q:~#ceph osd crush add-bucket ssd-rack03 rack
root@ceph01-q:~#ceph osd crush add-bucket hdd-rack01 rack
root@ceph01-q:~#ceph osd crush add-bucket hdd-rack01 rack
root@ceph01-q:~#ceph osd crush add-bucket hdd-rack01 rack
# Сервера
root@ceph01-q:~#ceph osd crush add-bucket ssd-ceph01-q host
root@ceph01-q:~#ceph osd crush add-bucket ssd-ceph02-q host
root@ceph01-q:~#ceph osd crush add-bucket ssd-ceph03-q host
root@ceph01-q:~#ceph osd crush add-bucket hdd-ceph01-q host
root@ceph01-q:~#ceph osd crush add-bucket hdd-ceph02-q host
root@ceph01-q:~#ceph osd crush add-bucket hdd-ceph02-q host

futhi basakaza amadiski ngokwezinhlobo zawo kumaseva ahlukene

root@ceph01-q:~# Диски с 0 по 3 это SSD, находятся в ceph01-q, ставим их в сервер 
root@ceph01-q:~#  ssd-ceph01-q
root@ceph01-q:~#ceph osd crush add 0 1 host=ssd-ceph01-q
root@ceph01-q:~#ceph osd crush add 1 1 host=ssd-ceph01-q
root@ceph01-q:~#ceph osd crush add 2 1 host=ssd-ceph01-q
root@ceph01-q:~#ceph osd crush add 3 1 host=ssd-ceph01-q
root-ceph01-q:~# аналогично с другими серверами

Ngemva sisabalalise amadiski phakathi kwemizila ye-ssd-root kanye ne-hdd-root, sishiye okuzenzakalelayo kwempande kungenalutho, ukuze sikwazi ukuyisusa.

root-ceph01-q:~#ceph osd crush remove default

Okulandelayo, sidinga ukudala imithetho yokusabalalisa esizoyibophezela kumachibi adalwayo - emithethweni sizobonisa ukuthi yiziphi izimpande ezingabeka idatha yethu ye-pool kanye nezinga lokuhlukile kwe-replica - isibonelo, ama-replicas kufanele abe kumaseva ahlukene, noma kuma-racks ahlukene (ungakwazi ngisho nezimpande ezahlukene, uma sinokusatshalaliswa okunjalo)

Ngaphambi kokukhetha uhlobo, kungcono ukufunda imibhalo:
http://docs.ceph.com/docs/jewel/rados/operations/crush-map/#crushmaprules

root-ceph01-q:~#ceph osd crush rule create-simple rule-ssd ssd-root host firstn
root-ceph01-q:~#ceph osd crush rule create-simple rule-hdd hdd-root host firstn
root-ceph01-q:~# Мы указали два правила, в которых данные реплицируются 
root-ceph01-q:~# между хостами - то есть реплика должна лежать на другом хосте,
root-ceph01-q:~# даже если они в одной стойке
root-ceph01-q:~# В продакшене, если есть возможность, лучше распределить хосты
root-ceph01-q:~# по стойкам и указать распределять реплики по стойкам:
root-ceph01-q:~# ##ceph osd crush rule create-simple rule-ssd ssd-root rack firstn

Hhayi-ke, sakha amachibi lapho sifuna ukugcina khona izithombe zediski ze-virtualization yethu esikhathini esizayo - PROXMOX:

    root-ceph01-q:~# #ceph osd pool create {NAME} {pg_num}  {pgp_num}
root-ceph01-q:~# ceph osd pool create ssd_pool 1024 1024 
root-ceph01-q:~# ceph osd pool create hdd_pool 1024 1024

Futhi sitshela lawa machibi ukuthi yimiphi imithetho yokubeka okufanele isetshenziswe

 root-ceph01-q:~#ceph osd crush rule ls # смотрим список правил
root-ceph01-q:~#ceph osd crush rule dump rule-ssd | grep rule_id #выбираем ID нужного
root-ceph01-q:~#ceph osd pool set ssd_pool crush_rule 2

Ukukhethwa kwenani lamaqembu okubekwa kufanele kuxhunyanwe nombono osuvele ukhona weqoqo lakho - cishe ukuthi mangaki ama-OSD azoba lapho, inani ledatha (njengephesenti levolumu ephelele) elizoba sechibini, yini inani ledatha.

Sekukonke, kuhle ukuthi ungabi namaqembu okubeka angaphezu kuka-300 kudiski, futhi kuzoba lula ukulinganisa namaqembu amancane okubeka - okungukuthi, uma i-pool yakho yonke ithatha i-10 Tb futhi ine-10 PG kuyo - bese ibhalansisa. ngokujikijela izitini ze-terabyte (pg) kuzoba yinkinga - uthele isihlabathi ngezinhlamvu zesihlabathi ezincane zibe amabhakede kalula futhi ngokulinganayo).

Kodwa kufanele sikhumbule ukuthi uma likhulu inani lama-PG, kulapho izinsiza ezengeziwe zisetshenziswa ekubaleni indawo yazo - inkumbulo ne-CPU ziqala ukusetshenziswa.

Ukuqonda okungalungile kungase nginike umshini wokubala, ehlinzekwe abathuthukisi bemibhalo ye-CEPH.

Uhlu lwezinto:

https://blog.packagecloud.io/eng/2017/02/06/monitoring-tuning-linux-networking-stack-sending-data
http://www.admin-magazine.com/HPC/Articles/Linux-I-O-Schedulers
http://onreader.mdl.ru/MasteringCeph/content/Ch09.html#030202
https://tracker.ceph.com/issues/23386
https://ceph.com/pgcalc/

Source: www.habr.com