Ukuqashwa kweseva okunikezelwe eCzech Republic kwamaphrojekthi ezinkampani
Thenga iseva ekude ePrague ngesiqinisekiso sesikhathi sokusebenza esingu-99.99%
Amaseva ashibhile eCzech Republic
Iseva enikezelwe ePrague - indawo ezinzile eYurophu Ephakathi
Isikhungo saseYurophu
Ukufinyelela okusheshayo ngokulinganayo ezimakethe zaseNtshonalanga, eMpumalanga naseNingizimu Yurophu.


Ukuzinza kwezombusazwe
I-Czech Republic iyindawo engathathi hlangothi futhi evikelekile yokusungulwa kwebhizinisi lesikhathi eside.
Ikhwalithi ngamanani aseCzech
Izinga lezikhungo zedatha zaseJalimane, kodwa ngamanani aguquguqukayo.


Ukubuka okuqondile
Ukufakwa ezindaweni zokushintshana kwedatha eziyinhloko zaseCzech naseYurophu.
Kungani ukhetha le nkampani? ProHoster

Ukufinyelela kwe-IPMI kokuphathwa kweseva

Ukusebenza kweseva kungakapheli amahora ama-2

Ukufaka i-OS yakho kanye nezithombe zakho ze-ISO

Amathuba okuxhuma amanethiwekhi e-IPv4/24 kanye ne-IPv6/48

Iphaneli yokulawula elula futhi esebenza ngezindlela eziningi
Qasha iseva ezinikezele e-Czech Republic
Ukuqashwa kweseva e-Czech Republic - Ifanelana kahle nezidingo zakho ze-IT, amaseva angakala futhi asebenza kahle ahlinzeka ngezixazululo ezinamandla zekhompiyutha ngentengo ethengekayo. Inethiwekhi yethu yesikhungo sedatha yakhelwe ukunikeza umsebenzisi ukubambezeleka okuncane kanye noxhumano olusheshayo lomhlaba wonke lweseva esingethwe esikhungweni sethu sedatha.
Thenga amaseva ashibhile eCzech Republic
Thola iseva efanele ezinikele evumelana nezidingo zakho

Idatha ye-LC PRG3
$65 ngenyanga
-
CPU I-Intel Xeon E3-12xx-v3-v6 (ama-cores angu-4/imicu engu-8, 3.6Ghz) -
IDISKI 2x500GB SSD -
RAM 32GB ECC -
PORT 100Mbps -
I-IPv4 1 -
I-IPv6 1 -
I-KVM I-IPMI+IP KVM
Ukuphromotha! Ukufakwa ngu-12$?

I-PRG1
$110 ngenyanga
-
CPU I-Intel Xeon E3-12xx-v3-v6 (ama-cores angu-4/imicu engu-8, 3.6Ghz) -
IDISKI 2x1TB SSD -
RAM 32GB ECC -
PORT 100Mbps -
I-IPv4 1 -
I-IPv6 1 -
I-KVM I-IPMI+IP KVM

I-PRG2
$122.5 ngenyanga
-
CPU I-Intel Xeon E-2xxx (ama-cores angu-6/imicu engu-12, 3.5+ GHz) -
IDISKI 2x500GB NVMe -
RAM 64GB ECC -
PORT 100Mbps -
I-IPv4 1 -
I-IPv6 1 -
I-KVM I-IPMI+IP KVM

I-PRG4
$320 ngenyanga
-
CPU I-Intel Xeon Scalable Gold (ama-core angu-20/imicu engu-40) -
IDISKI 2x2TB NVMe -
RAM 256GB ECC -
PORT 100Mbps -
I-IPv4 1 -
I-IPv6 1 -
I-KVM I-IPMI+IP KVM
Isikhungo Sedatha se-Master DC (ePrague, eCzech Republic) — incazelo yobuchwepheshe kanye namapharamitha
Indawo yendawo
Isikhungo sedatha Master DC etholakala e- Kodanska 46, 101 00 Prague 10, Czech Republic — enkabeni yengqalasizinda ye-IT yaseYurophu, enokufinyelela okuhle kwezokuthutha kanye nokuxhumana namanethiwekhi amakhulu esifundeni. Iyingxenye yesakhiwo sesimanje. I-4D-Center Prague, eyenzelwe amaphrojekthi ezinkampani kanye nemithwalo eminingi.
| isigaba | Ishidi le-data |
| Izinga lokuthembeka | Isigaba III, (I-SLA 99.99%) |
| Inani eliphelele lokukhipha | 450 Gbps + |
| Ubuchwepheshe obuluhlaza | Ukusebenzisa ukushisa okweqile ekufudumaleni amahhovisi |
| Питание | Ukucushwa komugqa wamandla we-2N |
| I-UPS | I-APC/Schneider Electric (N+1) |
| Amajeneretha | Izinjini zedizili ze-caterpillar |
| Ukuphola | Ukupholisa amanzi okungu-N+1 kanye nokupholisa kwamahhala |
| Ukucima umlilo | Uhlelo Lwegesi lwe-FM200 (Iphephile Kuma-elekthronikhi) |
| Izitifiketi | ISO 27001 (ukuphepha kolwazi), ISO 9001 |
| Ukuxhumana | Amaphuzu okushintshanisa i-NIX.CZ, i-Peering.cz |
| Ukuphepha | Amakhadi e-chip, i-biometrics, ukuqapha okungu-24/7 |
Imingcele evamile kanye nengqalasizinda
🔹 Indawo yesikhungo sedatha: more 850 m² wendawo esebenzayo, inganwetshwa ngokwezidingo.
🔹 Unyaka wokuvula: 2008, iminyaka eminingi yesipiliyoni ekuzinzeni kokusebenza.
🔹 Uhlobo: Isikhungo sedatha sesimanje sezentengiselwano esinezinsizakalo zokubeka indawo kanye nokusingatha.
🔹 Ukufinyelela: Ukufinyelela okungu-24/7 kwamakhasimende nabasebenzi bezobuchwepheshe.
🔹 Ukuxhaswa: Usekelo lobuchwepheshe olusebenza amahora angu-24 ngosuku, izinsuku ezingu-7 ngesonto kanye nosizo olusebenza kude.
🔹 Izinga lokufinyeleleka: ukuze 99.99% isikhathi sokuphumula.
Ukunikezwa kukagesi kanye nokungasebenzi kahle
Isikhungo sedatha se-Master DC sakhiwe nge izinga eliphezulu lokungasebenzi kahle kokunikezwa kwamandla, kubalulekile ekusebenzeni okuzinzile kwamaseva kanye nemishini yokubeka izinto endaweni:
✔ Amasekethe kagesi azimele amabili (iGatsha A no-B) - zombili ziphakelwa ngama-transformer ahlukene ane-voltage ephezulu (1,250 kVA A kanye no-B).
✔ I-UPS (ukunikezwa kwamandla okusekelayo):
- Igatsha A: I-Online N+1 UPS (4× 200 kVA)
- Igatsha B: I-UPS Esetshenziswa Ku-inthanethi (500 kVA)
✔ Amajeneretha kadizili: - Igatsha A – 2 × 700 kVA enokwabelana ngomthwalo
- Igatsha B — 1×1 650 kVA
✔ Umthamo kaphethiloli: izinsuku eziningana zokusebenza ngokuzimela, izivumelwano zokuhlinzekwa kukaphethiloli ngesikhathi sokungasebenzi isikhathi eside.
✔ Amayunithi wokusabalalisa amandla (i-PDU): Isekela amadivayisi anezivikelo ze-10A, 16A kanye ne-32A.
✔ Ukushintshela ngokuzenzakalelayo ku-backup ngemva kwemizuzwana engama-40.
✔ Isakhiwo sokubhukha: 2N+1, enikeza izinga eliphezulu lokubekezelela amaphutha okunikezwa kwamandla.
Uhlelo lokupholisa
I-Master DC iyasebenza uhlelo lokupholisa oluhlanganisiwe ngokubhukha N + 1, okuhlanganisa:
✔ Ukupholisa kwamahhala, okuvumela ukusetshenziswa komoya obandayo wangaphandle ukuze kuphole uma kungenzeka.
✔ Izitezi eziphakanyisiwe ukusatshalaliswa komoya okufanayo.
✔ Imizila ehlukene ebandayo neshisayo ukuze kujikelezwe umoya kahle.
✔ Amamojula okulawula isimo sezulu eStulz naseVertiv ngomjikelezo wokupholisa ophindaphindayo.
✔ Izinga lokushisa eligcinwe: ~22–25 °C ezindaweni ezibandayo (izindinganiso zezimboni).
✔ Umswakama ogciniwe: ~40–60%.
Lokhu kuqinisekisa ukusebenza okuzinzile kwemishini ngaphandle kokushisa ngokweqile ngisho nangaphansi komthwalo omkhulu.
Amandla erekhi kanye nokulungiswa kokubekwa
Izipesheli ze-Master DC izinketho eziguquguqukayo zokufaka i-rack:
✔ Amakhabethe e-Rittal TS IT afakwe erekhini afinyelela ku-47U (ubukhulu obujwayelekile 600×2200×1000 mm noma 800×2200×1200 mm).
✔ I-half rack (24U) и ikota yerakhi (10U) ukubekwa kwengxenye yesikhumba.
✔ Izakhiwo ezinezitezi eziningi kwezindawo zokubeka i-rack noma izindawo zokufaka ezenziwe ngokwezifiso.
✔ Izintambo zikagesi ze-UTP kanye ne-power cables ukufakwa okusheshayo.
✔ Amathuba okuxhuma amadivayisi nge amandla amabili A/B ngokutholakala okuphezulu.
✔ Amazinga ahlukahlukene obuningi bokubekwa ngokwezidingo zamakhasimende.
Ukuphepha ngokomzimba kanye nokuqapha
Ukuphepha nokulawula ukufinyelela kusetshenziswa ngezindinganiso eziphakeme:
✔ Ukulawula ukufinyelela okunamazinga amaningi (I-RFID, i-biometrics).
✔ ukuphepha ngokomzimba amahora angu-24 ngosuku, izinsuku eziyi-7 ngesonto kanye nabasebenzi bezobuchwepheshe endaweni.
✔ Uhlelo Lokuthola Ukungena (i-IDS) kanye nezinhlelo ze-alamu.
✔ Ukuqapha ividiyo ye-CCTV ngokugcinwa kwamarekhodi.
✔ Uhlelo lokucisha umlilo oluzenzakalelayo i-FM-200 ngegesi enobungani nemvelo.
✔ Izinhlelo zesimanje zokuthola umusi nokushisa.
Ingqalasizinda yenethiwekhi kanye nokuxhumana
I-Master DC inengqalasizinda yenethiwekhi enamandla:
✔ Ukuxhumeka kwe-N× 100 Gbps, isivinini sembobo esiguquguqukayo 1/10/25/40/100 Gbps.
✔ Ukuxhumana okuqondile: I-CeColo, i-THP kanye ne-MasterDC Brno yokuxhumana kwenethiwekhi okuqondile.
✔ Kungenzeka ukuxhumana nge-SFP, SFP+, QSFP nezinye izixhumi.
✔ Ukungasebenzi kahle kwenethiwekhi okuyingxenye yokushintsha okuzenzakalelayo uma kwenzeka ukwehluleka.
✔ Ukuhlanganiswa okulula nabahlinzeki bamafu namanethiwekhi angaphandle.
Amasevisi nokwesekwa
I-Master DC inikeza uhla oluphelele lwezinsizakalo zesikhungo sedatha:
✔ Indawo yokuhlala (ama-rack/amakhabethe/amakamelo/izixazululo ezenziwe ngokwezifiso)
✔ Ukusingathwa kweseva okuzinikele
✔ Izixazululo zefu ne-VPS
✔ Izinsizakalo zokuphathwa kwengqalasizinda yeseva ne-IT
✔ Izandla ezikude 24/7
✔ Amakamelo amaklayenti ngokufinyelela ku-inthanethi ukuze usebenze ngemishini
Le ngqalasizinda ifanelekela kokubili izinkampani ezintsha kanye namaphrojekthi ezinkampani, i-eCommerce, i-CDN, i-VPN kanye nezinhlelo ze-IT ezingandiswa.
Izinzuzo zokuba sePrague
✔ Indawo ephakathi eYurophu – ukubambezeleka okuphansi kanye nemizila yenethiwekhi emihle kakhulu.
✔ Ukufinyelela okusheshayo emigwaqweni emikhulu i-Arelion, i-RETN, i-O2, i-UPC kanye nemigwaqo emikhulu yamazwe ngamazwe i-IX.
✔ Ingqalasizinda yezokuthutha kanye nezokuthutha ethuthukisiwe.
✔ Ukufinyeleleka okuhle kakhulu emsebenzini wasendaweni kanye nokulungiswa kwemishini.
Thenga iseva ekude eCzech Republic
Thenga iseva ezinikezele e-Czech Republic - amaseva anendawo ekahle yendawo cishe isikhungo saseYurophu, okuheha ukunakwa kwezinkampani eziningi ezihilelekile ekuthuthukisweni kwezikhungo zedatha. Okwamanje ku I-Czech Republic Izikhungo ezinkulu zedatha zifakwe kusetshenziswa izingxenye nemishini yesimanjemanje. Ngamaseva anamandla, ama-racks ahlinzeka ngesivinini esiphezulu nezisombululo ezivikelekile kumakhasimende eseva azinikezele.
Izibuyekezo zenkampani ProHoster
Imibuzo evame ukubuzwa
| Iyini isikhungo sedatha se-Master DC ePrague? | ||||||||||
I-Master DC iyisikhungo sedatha yezentengiselwano sesimanje ePrague, eCzech Republic, esenzelwe ukuhlukaniswa kwezindawo, ukusingathwa kweseva okuzinikele, ukubalwa kwamafu, kanye nezixazululo ze-IT zebhizinisi. Lesi sikhungo siyingxenye yengqalasizinda ye-MasterDC futhi sigxile ekuthembekeni okuphezulu, ukuphepha, kanye nokukhula. | ||||||||||
| Isikhungo sedatha se-Master DC sitholakala kuphi? | ||||||||||
Isikhungo sedatha sitholakala ePrague, eCzech Republic, eKodanská 46, 101 00 Prague 10, eYurophu ephakathi. Le ndawo inikeza: | ||||||||||
| Lingakanani izinga lokuthembeka kwe-Master DC? | ||||||||||
Isikhungo sedatha senzelwe amazinga e-Tier III, afaka: | ||||||||||
| Ugesi uhlelwa kanjani eMaster DC? | ||||||||||
Ukunikezwa kukagesi kwesikhungo sedatha kuklanywe kusetshenziswa umklamo obekezelela amaphutha: | ||||||||||
| Ingabe kukhona ukungasebenzi kahle kwamandla ezingeni le-rack? | ||||||||||
Yebo, i-Master DC inikeza: | ||||||||||
| Uhlobo luni lokupholisa olusetshenziswa esikhungweni sedatha? | ||||||||||
I-Master DC isebenzisa: | ||||||||||
| Ingabe isikhungo sedatha siyawusekela ubuningi obukhulu? | ||||||||||
Yebo, ingqalasizinda ye-Master DC ivumela: | ||||||||||
| Yimaphi amandla atholakalayo nge-rack ngayinye? | ||||||||||
Isikhungo sedatha sinikeza izinketho zamandla eziguquguqukayo: | ||||||||||
| Yisiphi ingqalasizinda yenethiwekhi etholakalayo? | ||||||||||
I-Master DC inenethiwekhi ethuthukisiwe: | ||||||||||
| Ingabe i-Master DC ifanelekile kumaphrojekthi aphesheya kwezilwandle? | ||||||||||
Yebo, isikhungo sedatha silungele: | ||||||||||
| Yiziphi izindlela zokuphepha ezisetshenziswayo? | ||||||||||
Isikhungo sedatha sisebenzise: | ||||||||||
| Ingabe bakhona abasebenzi abaqashwe ngokugcwele esikhungweni sedatha? | ||||||||||
Yebo, i-Master DC inabasebenzi bezobuchwepheshe abafanelekayo abasebenza amahora angu-24 ngosuku, izinsuku eziyi-7 ngesonto ukuze basheshe basebenze: | ||||||||||
| Ingabe amakhasimende ayakwazi ukufinyelela imishini? | ||||||||||
Yebo, amakhasimende anikezwa: | ||||||||||
| Kungani ukhethe iMaster DC ePrague? | ||||||||||
Izinzuzo Eziyinhloko: | ||||||||||
| Yimiphi imisebenzi iMaster DC ePrague efaneleka kakhulu kuyo? | ||||||||||
Isikhungo sedatha silungele kakhulu: |




















